Loading...
Plans AERIAL SITE VIEW JURISDICTION CODES AND STANDARDS VERNING CODES ;y I.GOALL WORK SHALL COMPLY WITH: . .„:„. _.r.4-t: 2021 OREGON ELECTRICAL SPECIALTY CODE(0 SC) (OESC) x /11Fr ' 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) r 2021 OREGON RESIDENTIAL SPECIALTY CODE(ORSC) 2018 INTERNATIONAL FIRE CODE(IFC) p� �,� n 2021 OREGON PLUMBING SPECIALTY CODE !ll��� AND ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. AUG y •a _ 414 , - e © ZQ?'� CONFIDENTIAL-THE INFORMATION R. • • //y HEREIN CONTAINED SHALL NOT BE USED ,, , ,'1,, -..., '''' :,::. '': .: • ,;,',3,:r4, 1..,,,,*-4',7:,',-,.P.',.i. ,::.:: • :' V� >I(�r�yJr-� FOR THE BENEFIT OF ANYONE EXCEPT ION ,� e4aL SITE CLASSIFICATION NOTES,OSHA REGULATION Mn�lt� DEVELOPER,LLC NOR SHALL IT BE OCCUPANCY CLASS: SFR �UILp�N�DIVISION DISCLOSED IN WHOLE OR IN PART TO IVIS O� OTHERS OUTSIDE RECIPIENTS i t, CONSTRUCTION CLASS: V-6 X ZONING TYPE: RESIDENTIAL ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE "` RESPECTIVE EQUIPMENT,WITHOUT THE * ;- 'a, �— I. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. WRITTEN PERMISSIONION DEVELOPER, d'6 OF R wvA 2. THIS PROJECT HAS BEEN REVIEWED AND WILL NOT DIRECT CONCENTRATED SOLAR RADIATION OR GLARE LLC. • ° �� ONTO NEARBY PROPERTIES OR ROADWAYS. �° ' -i I s 3. FOR PROJECTS SUBMITTED FOR PRESCRIPTIVE REVIEW,ROOF ATTACHMENTS SHALL BE SPACED NO GREATER *7 . =i..� , , .. THAN 24"ON CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE,HIP,EAVE,OR RIDGE OSSC IKIABCEls ' _ x:� 9 ' -: ;`'- "T'�x 3111.3.5.3 ITEM 3,2 "_" T' s ' ELECTRICAL CRITERIA,NOTES CERTIFIED r TEMPERATURE SOURCE: ASHRAE t 8 SV . ,• ci - PV INSTALLATION '1. _ ' r WEATHER STATION: PORTLAND HILLSBORO PROFESSIONAL ' EXTREME MIN. TEMPERATURE: -8 .cr -07, i 0 dr° ASHRAE 0.4%HIGH TEMP: 37 SCOTT A. GURNEY �e a d 0 - � #PV-0117719-015866 r I. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS.' ION DEVELOPER,LLC 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED)IN =a. . 'gym I 4801 N UNIVERSITY AVE#900 PROVO, UT y k." • ACCORDANCE WITH NEC 110.14(D)ON ALL ELECTRICAL. 84604 4 3. PV MODULE CERTIFICATIONS WILL INCLUDE ULI703, IEC61646,IEC61730. 888.781.7074 a M • • 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO ' # ''*-4? 0 � LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. DAVID STANLEY CONRAD .111 � . C-ELECTRICAL CONTRACTOR • aC w 5. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL *.4.:;,:7;.::'?,:',..,:.,,, § *, BE PROVIDED AS PER SECTION[NEC 110.26]. CI524 LIABILITY A' ` = ,. F The City of Tigard and its ': irlizi�, av - - STRUCTURAL CRITERIA,NOTES c �' $, DESIGN LOAD STANDARD: ASCE 7-16 employees shall not be ' a� .4.'''." * { WIND EXPOSURE CATEGORY: B WIND SPEED(3-SEC GUST): 96 MPH LLJ responsible for discrepancies ,+ GROUND SNOW LOAD: 36 PSF uvhich may appear herein. z o DESIGN ROOF SNOW LOAD: 26 PSF Q + ; SEISMIC DESIGN CATEGORY: D J N SEISMIC RISK FACTOR: II N 0 h 0 U U .-..-, ::INIU,‘If::,'' r., �. v s II I _ CITY OFTIGAP+ } w o a W N i W N U REVIEWED FOR CODE COMPLIANCE z N ro ^ N ` Approved: [� Z �' U d O'l'C: [ ] 2 Q u z C co co v ' 46* % w AltOFFICE COPY Permit#: IDS l Zoj .— 0633 S z _ 0tiJ o - N �cz _ Address: ,��% 6‘'`� t '{C e,1 LJto o Q = o N SCOPE OF WORK SHEET LIST }: Date: 13 ZZ N Y o � co Io N TALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM G-I COVER SHEET DRAWING BY V-2 SITE PLAN (AD. LIB) �v PROFS, ENPHASE ENERGY 3.04 KW DC & 2.384 KW AC PHOTOVOLTAIC SOLAR ARRAY S 3 ROOF PLAN t�' `s.S �� G I Nee /o DATE S-4 STRUCTURAL DETAILS C.1 c,� 4, ti S-5 STRUCTURAL CALCULATIONS 8. NOTES VALIDITY OF PERMIT 91' I9-AuG-2022 PV MODULES: (8) SILFAB SOLAR SIL-380 HC 20211101 E-6 ELECTRICAL DETAILS (LINE DIAGRAM) THE ISSUANCE OF A PERMIT / 9 950P BASED ON CONSTRUCTION ( PROJECT ID INVERTER(S): (8) ENPHASE IO8PLUS-72-2-US E-7 ELECTRICAL CALCULATIONS & NOTES OREGON 007NPW E-8 ELECTRICAL LOAD CALCULATIONS (AD. LIB) DOCUMENTS AND OTHER ROOF TYPE: COMPOSITION SHINGLE - I LAYER(S) E-9 ELECTRICAL LABELS & LOCATIONS DATA SHALL NOT PREVENT `�qN Otis ��� 2 SHEET NAME E I0 ELECTRICAL DIRECTORY PLACARD (AD. LIB) THE CODE OFFICIAL FROM q�4N ROw�F,y 08/23/2022 COVER SHEET PV MOUNTING HARDWARE: ECOFASTEN CLICKFIT REQUIRING THE CORRECTION OF ERRORS.ORSC 105.4 EXPIRES:12/31/24 SHEET NUMBER REVISON G-I 0 SITE NOTES: I. FOR PROJECTS SUBMITTED FOR PRESCRIPTIVE REVIEW, ROOF ATTACHMENTS SHALL BE SPACED NO ION GREATER THAN 24" ON CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, OR RIDGE OSSC 3111.3.5.3 ITEM 3.2 FOR ANY METER UPGRADES, ENSURE THAT THE UTILITY METER IS LOCATED WITHIN 'OFT OF THE CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FRONT/STREET-SIDE OF THE HOUSE. PLEASE ADD A FOR THE BENEFIT OF ANYONE EXCEPT ION L SHOWING THE DISTANCE FROM THE FRONT DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO CORNER OF THE HOUSE. IIIIIIIIhliL+++ OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION 11_OnWITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ION DEVELOPER, LLC. ONABCEPCERTIFIED PV INSTALLATION 00 PROFESSIONAL , . SCOTT A. GURNEY + / #PV-0117719-015866 0 ++ ION DEVELOPER,LLC 4801 N UNIVERSITY AVE#900 PROVO, UT O 84604 0 888.781.7074 0 CHIMNEY 4 DAVID LEY CONRAD C -ELECTRICAL CONTRACTOR CI524 v6),J 1 '4\ w �', Q o 4# NI 4 J cu es, o = 1 L fir,. Q LLJ O N 1 0 N Q J cj) Q 4V; r---- RSI �,C o v~) z UJ 0 Q wLLI o o - � � Q S N �p PROF P E S LLI W w h :'\ ..\� GIN£LF`S`S/p ��`� o 0 o o a = o ', �\ `� �� OP z 2 V) J Z N 9 950P� ,x." �5 UI I— Lu g OREGON �0 �� c7i Y ~ co co o O� CD DRAWING BY 4H 11, 20`L �Q- �� ENPHASE ENERGY SCALE: I/8" = I' O" q�4N ROW\'C' 08/23/2022 �`'� DATE 2 8 EXPIRES:12/31/24 19-AuG-2022 SYSTEM LEGEND ROOF PV MODULE PROJECT ID (N) (N) PV COMBINER PANEL J(N)( (N)JUNCTION BOX s# SUNEYE LOCATION ROOF SECTION SECTION OTY AZIMUTH PITCH TSRF 007NPW CRITERIA AND RSI 8 224 23 93% lE)1 (E)UTILITY METER / (N) (N) (N)AC DISCONNECT �MJ MAIN SERVICE PANEL Lc (N)PV LOAD CENTER ACD (VISIBLE OPEN LOCKABLE LABELED DISCONNECT) ;.. FIRE SETBACK SPECIFICATIONS SHEET NAME MAIN (E) MAIN SERVICE PANEL P( (N) PV PRODUCTION DCAC (N)MICROINVERTER 0 ROOF PLAN �J METER AC (N)PV MODULE sue (E) SUBPANEL (N) (N) DC-DC / STRING (N) (N) DC DISCONNECT SHEET NUMBER BENISON I INVERTER DCD S_3 RACKING INSTALLATION SCHEDULE AND STRUCTURAL CRITERIA 7PV MODULE PV RACKING SPAN AREA TAG SPAN rPV MOUNTING RAIL ION RACKING: ECOFASTEN CLICKFIT RAIL -PORTRAIT-MODULE ORIENTATION } r4 1 1 1 � TRAIT RACKING TYPE: RAIL X-SPACING P-XI 48 IN. O.C. MAX. M RORIENTATION STANDOFF: CLICKFIT L-FOOT X-CANTILEVER P-X2 16 IN. MAX. STANDOFF TYPE: L-FOOT&FLASHING Y-SPACING P-YI 37.4 IN. MIN. -45.3 IN. MAX. 5/16"X 3-1/2"ZINC PLATED PV ARRAY DETAIL, FRONT VIEW —P-X2 P-XI FASTENER: STEEL LAG SCREW Y-CANTILEVER P-Y2 12.1 IN. MIN. - 16 IN. MAX. SCALE: 3/8" = I'-0" 1 I� t CONFIDENTIAL-THE INFORMATION I HEREIN CONTAINED SHALL NOT BE USED LANDSCAPE STRUCTURAL RAIL-LANDSCAPE-MODULE ORIENTATION �1 IL N ? FOR THE BENEFIT OF ANYONE EXCEPT ION ORIENTATION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO g+ ROOF TYPE: COMPOSITION SHINGLE X-SPACING L-XI 48 IN. O.C. MAX. ROOF SHEATHING TYPE: 1/2"PLYWOOD X-CANTILEVER L-X2 16 IN. MAX. —L-X2— L-XI OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION STRUCTURE TYPE: MANUFACTURED WOOD TRUSS Y-SPACING L-YI 21.1 IN. MIN. -25.1 IN. MAX. WITH THE SALE AND USE OF THE RAFTER SIZE: 2x4 Y-CANTILEVER L-Y2 7.9 IN. MIN. -9.8 IN. MAX. RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ION DEVELOPER,RAFTER SPACING: 24 PORTRAIT ORIENTATION LLC. ARRAY PARAMETERS TOTAL ROOF AREA(SQ. FT.) 2000 P-Y2 -\IABCEP TOTAL PV MODULE AREA(SQ. FT.) 157.6 PV MODULE ROOF COVERAGE 8% \ L-Y2 CERTIFIED LANDSCAPE1111411. ORIENTATION PV INSTALLATION P YI ---1\ joi. / PROFESSIONAL rj-' SCOTT A. GURNEY PV ARRAY DETAIL, SIDE VIEW 1�� 7 #PV-0117719-015866 // ION DEVELOPER,LLC SCALE: 3/8 = I 0° , 4801 N UNIVERSITY AVE#900 PROVO,UT 84604 / 888.781.7074 DAVID STANLEY CONRAD L YI RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH C-ELECTRICAL CONTRACTOR SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER C1524 TO DISTRIBUTE LOAD ACROSS ALL FRAMING MEMBERS UNDER PV ARRAY. UJ z O Q J N O PV MODULE o o a = j " UI NIa1 O N ? ^ U) U CLICKFIT RAIL O o Cl)) D a O N zCC Lu 6" CLICKFIT L-FOOT c=n = oN LLJ NCC 0 Illll�i O u_ coO O Ct CO = U n Z (n 6 J N - (E) COMP SHINGLE w Q (n w MB F- 00 (0 .. O . � if'ROOF MEMBRANE Y , oo ao rfi DRAWING BY COMP SHINGLE FLASHING �E� I N PROFF ENPHASE ENERGY I 22" MIN. �'� `Ssj DATE I DEPTH 5/16" ZINC PLATED STEEL �v�� ��GFF� p9 19-AUG-2022 11 LAG SCREW WITH 2-1/2" Lk9 950P MIN. EMBEDMENT IN TO c.„.,.... (E) ROOF RAFTER PROJECT ID OREGON 007NPW 0 STANDOFF DETAIL `�qH 0`1� SCALE: 3" = I'-0" q� 11, 2 F.� 08/23/2022 SHEET NAME qN RO`N� STRUCTURAL DETAILS EXPIRES:12/31/24 SHEET NUMBER REVISON S-4 0 PV SYSTEM STRUCTURAL SPECIFICATIONS AND CALCULATIONS PV SYSTEM EQUIPMENT SPECIFICATIONS DESIGN LOCATION AND SITE SPECIFICATIONS GRAVITY LOAD / FRAMING CALCULATIONS MODULE MANUFACTURER / TYPE SILFAB SOLAR SIL-380 HC 20211101 JURISDICTION DEAD LOAD (PSF) RSI ION SOLAR MODULE WEIGHT (LBS) 43 CITY OF TIGARD ROOF MEMBRANE COMPOSITION 4.0 SOLAR MODULE LENGTH (IN.) 69.4 STATE OREGON SHINGLE SOLAR MODULE WIDTH (IN.) 40.8 ADOPTED LOAD STANDARD ASCE 7-16 SHEATHING 1/2" PLYWOOD 1.7 SOLAR MODULE AREA(SQ. FT) 19.7 OCCUPANCY / RISK CATEGORY II PV RACKING ECOFASTEN CLICKFIT BASIC WIND SPEED(MPH (3-SEC GUST)) 96 CONFIDENTIAL-THE INFORMATION PV HEREIN CONTAINED SHALL NOT BE USED RACKING TYPE RAIL WIND EXPOSURE CATEGORY B MANUFACTURED FOR THE BENEFIT OF ANYONE EXCEPT ION PV ROOF ATTACHMENT CLICKFIT L-FOOT GROUND SNOW LOAD(PSF)(PG) 36 WOOD TRUSS - TOP DEVELOPER,LLC NOR SHALL IT BE +� 5/16"X 3-1/2" ZINC PLATED STEEL LAG FRAMING CHORD 2X4 @ 24 IN. 1.0 DISCLOSED IN WHOLE OR IN PART TO PV ROOF ATTACHMENT FASTENER SCREW BASE ELEVATION (FT) 153 0.C. - DF #2 @6 FT. OTHERS OUTSIDE RECIPIENTS KIN DEAD LOAD PSF 0.g MAX SPAN ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE SOLAR MODULE DEAD LOAD (PSF) 2.18 DESIGNED ROOF SNOW LOAD CALCULATIONS ASCE 7-16 (C&C) RESPECTIVE EQUIPMENT,WITHOUT THE TOTAL PV ARRAY DEAD LOAD (PSF) 2.98 SLOPED ROOF SNOW LOAD (PSF) EON. 7.4-I WRITTEN PERMISSION OF ION DEVELOPER, LLC. =Ps = (Cs)(0.7)(CE)(CT)(IS)(PG) TOTAL ROOF DEAD LOAD (PSF) 6.7 PV SYSTEM STRUCTURAL SPECIFICATIONS EXPOSURE FACTOR (CE) = 1.0 TABLE 7.3-I ADJUSTED TO SLOPED ROOF (PSF) 7.3 STRUCTURE TYPE -ROOF SHAPE INHABITED - GABLE / FLAT ROOF s THERMAL FACTOR (CT) = 1.0 TABLE 7.3-2 �AB C E P MIN. ROOF SLOPE (DEG.) 23 IMPORTANCE FACTOR (Is) = 1.0 TABLE 1.5-2 PV ARRAY ADJ. TO ROOF SLOPE (PSF) 3.3 MEAN ROOF HEIGHT (FT.) II SLOPE FACTOR (Cs) = 1.0 FIG. 7.4-I ROOF LIVE LOAD < ROOF SNOW LOAD (PSF) 26.0 CERTIFIED PORTRAIT ATT. SPACING (IN. O.C.) 48 Ps (PSF) = 26 OK TOTAL LOAD (PSF) 36.6 PV INSTALLATION LANDSCAPE ATT. SPACING (IN. O.C.) 48 # OF ATTACHMENT POINTS 20 RAFTER/ TOP CHORD MEMBER PROPERITES DF #2 - 2x4 PROFESSIONAL MAX. POINT LOAD (LBS / ATT.) 14.6 SECTION MODULUS (S)(IN"3) 3.06 cj.� /1 SCOTT A. GURNEY X. TOTAL PV DEAD LOAD TO RAFTER (LBS) 29.3 MOMENT OF INERTIA(1)(IN"4) 5.36 #PV-0117719-015866 MATOTAL LOAD ON MEMBER (W) (PLF) 73.1 ION DEVELOPER,LLC DESIGN WIND PRESSURE AND CONNECTION UPLIFT CALCULATIONS ASCE 7-16 (C&C) MAX. MEMBER SPAN (L)(FT) 6 4801 N UNIVERSITY AVE#900 PROVO, UT 84604 DESIGN WIND PRESSURE (PSF) =P = DH(GCP)(YE)(YA) EQN. 29.4-7 MODULUS OF ELASTICITY (E) (PSI) 1600000 888.781.7074 VELOCITY PRESSURE (PSF) =OH = 0.00256(KH)(KZT)(KD)(KE)(V"2) EQN. 26.10-I SHEAR (Fv) (PSI) 180 TERRAIN EXPO. CONSTANT (A) = 7 TABLE 26.11-I ARRAY EDGE FACTOR (YE) = I TABLE 26.13-I AREA(A)(IN"2) 5.25 DAVID STANLEY CONRAD TERRAIN EXPO. CONSTANT (ZG)(FT) = 1200 TABLE 26.11-I GROUND ELEVATION FACTOR (KE) = 0.99 FIG. 29.4-8 C-ELECTRICAL CONTRACTOR VP EXPOSURE COEFF.(KH) = 0.70 EQN. C26.10-I EQN. 26.10-I MAX BENDING STRESS CHECK (FB)(CD)(CF)(CR) CI524 TOPOGRAPHIC FACTOR (KzT) = 1.0 EQN. 26.8-I OH (PSF) = 13.96 BENDING (Fs)(PSI) 900 WIND DIRECTIONALITY FACTOR (KG) = 0.85 TABLE 26.6-I LOAD DURATION FACTOR (CD) 1.15 SIZE FACTOR (CF) 1.50 UPLIFT DOWNWARD REPETITIVE MEMBER FACTOR (CR) 1.15 GABLE ROOF 20° < 0 5 27° ZONE I ZONE 2R ZONE 2E ALL ZONES FIGURE 30.3-2C ALLOWABLE BENDING STRESS (PSI) 1785.4 W RAIL -PORTRAIT MODULE ORIENTATION 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. z O Q SOLAR PANEL PRESSURE EQ. FACTOR (YA) = 0.80 0.80 0.80 0.80 ACTUAL BENDING STRESS (PSI) = (wL"2)/(8(S)) 1289.7 J (V EXTERNAL PRESSURE COEFF. (GCP) _ -1.5 -2.5 -3.6 0.7 72% OK O O N ASD PRESSURE (0.6P)(PSF) = -10.05 -16.75 -24.12 13.03 TRIBUTARY AREA(SQ. FT) = 11.6 11.6 8.7 C.)MAX DEFLECTION CHECK - TOTAL LOAD UNIFORM DISTRIBUTED LU = 1 Q MAX. UPLIFT(0.6D+0.6P) (LBS) = -95.6 -173.1 -193.7 ALLOWABLE DEFLECTION L / 180 LU � C c...1 N U 0.400 IN. Y NI 1 F- � RAIL -LANDSCAPE MODULE ORIENTATION 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. ACTUAL MAX DEFLECTION (W)(L)"4 / 185(E)(I) Q n _- N Q SOLAR PANEL PRESSURE EQ. FACTOR (YA) = 0.80 0.80 0.80 0.80 0.103 IN. Z O J U EXTERNAL PRESSURE COEFF. (GCP) = -1.5 -2.5 -3.6 0.7 26% OK O (/) Z .j aa0 4 W ASD PRESSURE (O.6P)(PSF) _ -10.05 -16.75 -24.12 13.03 MAX DEFLECTION CHECK -LIVE LOAD Q LLI CD O - • TRIBUTARY AREA(SQ. FT) = 6.80 6.80 5.10 ALLOWABLE DEFLECTION L / 240 Z I LU Cl) LU N MAX. UPLIFT(0.6D+0.6P) (LBS) = -56.2 -101.7 -113.9 0.3 IN. p O O OO Q , ROOF ATTACHMENT FASTENER CHECK ACTUAL MAX DEFLECTION (W)(L)"4 / 185(E)(I) Z Cl) ll • NI ,„ CLICKFIT L-FOOT-5/16"X 3-1/2"ZINC PLATED NDS 12.2 0.086 IN. W = Q W STEEL LAG SCREW 29/o I Q co C.9 MANUFACTURER MAX. UPLIFT CAPACITY=359.6 LBS o N LC) I- co oo LAG SCREW WITHDRAWAL DESIGN VALUE (LBS) =W = I800(G"3/2)(D"3/4) 12.2.1 MAX SHEAR CHECK ROOF ATTACHMENT FASTENER (D) = 5/16 IN. LAG SCREW LUMBER SPECIFIC GRAVITY(G)= 0.5 TABLE 2.3.2 ALLOWABLE SHEAR Fv (A) DRAWING BY FASTENER QTY PER ATTACHMENT = I LOAD DURATION FACTOR (CD) = 1.6 TABLE I2.3.3A 945 LBS. ENPHASE ENERGY FASTENER EMBEDMENT DEPTH (IN.) = 2.5 PRYING COEFFICIENT = 1.4 ACTUAL MAX SHEAR (w)(L)/2 WITHDRAWAL DESIGN VALUE(W)(LBS/ IN.) = 266.0 _0 PROF `�� Fss 219 LBS. DATE LAG SCREW WITHDRAWL CAPACITY(LBS) = 760.0 I9 AUG ZOZZ MAX. ATT. WITHDRAWAL CAPACITY(LBS) = 359.6 > 193.7 MAX UPLIFT DEMAND (LBS) OK ��\� c,�G 0P,_ 09 23% OK 9 950P / / PROJECT ID OREGON 007NPW SHEET NAME q�qN v44, �ROW�,�c, 08/23/2022 STRUCTURAL CALCS SHEET NUMBER REVISON EXPIRES:12/31/24 S-5 0 CONDUCTOR AND RACEWAY SCHEDULE TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG CITY SIZE-# TYPE DESIGNATOR I/V TAG STY SIZE-# TYPE DESIGNATOR I/V 10 (I) 10 AWG THHN/ THWN, CU. BLACK (LI) 9.7A AC(MAX) 3 (I) 10 AWG THHN/THWN, CU. BLACK (LI) 9.7A AC (MAX) 2 (I) 10 AWG 2C,NM-B W/G, CU. (LI, L2, EGC) 9.7A AC (MAX) I (I) 12 AWG 2C, TC-ER,CU. (LI, L2) 9.68A AC(MAX) (I) 10 AWG THHN/THWN, CU. RED(L2) 240V AC (I) 10 AWG THHN/ THWN, CU. RED(L2) 240V AC FREE AIR 240V AC (I) 6 AWG SOLID BARE CU. (EGC) 240V AC (I) 10 AWG THHN /THWN, CU. WHITE (N) (I) 10 AWG THHN/THWN, CU. GREEN(EGC) (I) 3/4 IN. EMT OR FREE AIR (RACEWAY) ION (I) 10 AWG THHN /THWN, CU. GREEN (EGC) (I) 3/4 IN. EMT (RACEWAY) (I) 3/4 IN. EMT (RACEWAY) EXTERIOR EXTERIOR INTERIOR EXTERIOR CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE ELECTRICAL LINE DIAGRAM DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE (E)UTILITY (E)200A MAIN SERVICE PANEL LOAD-SIDE SOURCE CONNECTION (N)ENPHASE IQ COMBINER 3 RESPECTIVE EQUIPMENT,WITHOUT THE METER (E)I25A/2P MAIN DISCONNECT BUSBAR PLUG-IN TYPE BREAKER (PV CIRCUITS ONLY) WRITTEN PERMISSION OF ION DEVELOPER, (NEC 705.12) LLC. (8)SILFAB SOLAR SIL-380 HC 20211101 PV MODULE(S) L r SECONDARY POWER INTEGRATED UL 1703 LISTED SOURCE(PV OCPD)TO I5A/2P MAX BE LOCATED AT TO 10 ENVOY NAB C E I (E)I25A/2P OPPOSITE END OF GATEWAY (8)ENPHASEIQSPLUS-72-2-US MICROINVERTER(S)[240V] BUSBAR FROM PRIMARY • o�o-- UL 1741 LISTED CERTIFIED SOURCE(MAIN OCPD) -•o ilIND E (E)LOADS (NEC 705.12) (N)JUNCTION BOX (N)JUNCTION BOX PV INSTALLATION (OPTIONALO SPLICE) CONDUCTOR R PROFESSIONAL CONDUCTOR 120/240 VAC 60HZ ] A/2P 'S.✓ SCOTT A. (N)I5A/2P 7-1 #PV-0117719-015866GURNEY SINGLE PHASE L� CIRCUIT Ail 'UTILITYI �N LI L2 LI ���� 4801 N UNI ERSDITY AVE#900CPROVO, UT SERVICE Ng ecc _ _ — _ G +G< �_++- ® - I MODULES 84604 43.1 V J L 888.781.7074 G 0 DAVID STANLEY CONRAD 0 0 0 C-ELECTRICAL CONTRACTOR LI N L2 GEC CI524 (E)GROUNDING (ELECTRODE SYSTEM W Z O Q —J CV O O N p U Q = 1 Q W O CV I I U NI U) UaoET w Cl) �O Q w O Q c0 00 v W J C3 ELECTRICAL LINE DIAGRAM NOTES N = w o W N Y o D O CO Q I, Q = 0 • (V Z >- O C j 0 CC Z W i LSD Q (/) W F- Q a0 V .. --, O (n F- °o co N i DRAWING BY ENPHASE ENERGY DATE I9-AuG-2022 PROJECT ID 007NPW SHEET NAME ELEC. LINE DIAG. SHEET NUMBER REVISON E-6 0 PV SYSTEM ELECTRICAL SPECIFCATIONS AND CALCULATIONS DESIGN LOCATION AND TEMPERATURES RACEWAY / CONDUCTOR CALCULATIONS TEMPERATURE DATA SOURCE ASHRAE MICROINV. TO JUNCTION BOX (I) ION STATE OREGON MAX INVERTER OUTPUT CIRCUIT CURRENT = 9.7 A AC JURISDICTION CITY OF TIGARD MAX CURRENT X125% 12.0 A AC WEATHER STATION PORTLAND HILLSBORO PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) ASHRAE EXTREME LOW TEMP (°C) -8 CONDUCTOR SIZE / INSULATION / TYPE = 12 AWG 2C, TC-ER, CU. CONFIDENTIAL-THE INFORMATION CONTAINED SHALL NOT BE USD ASHRAE 0.4% HIGH TEMP (°C) 37 CONDUCTOR AMP. RATING @ 90°C = 30 A FORREIN THE BENEFIT OF ANYONE EXCEPT EON DEVELOPER,LLC NOR SHALL IT BE DESIGNED MAX. SYSTEM VDROP / VRISE 2.00% AMB. TEMP. AMP. CORRECTION = NOT APPLIED DISCLOSED IN WHOLE OR IN PART TO ADJUSTED AMPACITY COMPLIANCE (A) = 30 > 12.0 OK OTHERS OUTSIDE RECIPIENTS PV MODULE SPECIFICATIONS SILFAB SOLAR SIL-380 HC 20211101 ORGANIZATION,EXCEPT IN CONNECTION RACEWAY SIZE / TYPE = 3/4 IN. EMT OR FREE AIR WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE RATED POWER (PMAX) (W) 380 CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.142 IN.2 WRITTEN PERMISSION OF ION DEVELOPER, MAXIMUM POWER VOLTAGE (VMP) 35.32 CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN.2 LLC. MAXIMUM POWER CURRENT (IMP) 10.77 % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE I) = 53% > 27% OK OPEN CIRCUIT VOLTAGE (VOC) 42.17 NABCEP SHORT CIRCUIT CURRENT (ISC) 11.36 JUNCTION BOX TO JUNCTION BOX (2) PMP/VMP TEMP. COEFFICIENT -0.36 MAX INVERTER OUTPUT CIRCUIT CURRENT = 9.7 A AC CERTIFIED VOC TEMP. COEFFICIENT -0.28 MAX CURRENT X125% = 12 A AC PV INSTALLATION SERIES FUSE RATING 20 PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) PROFESSIONAL ADJ. MODULE VOC @ ASHRAE LOW TEMP 46.1 CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG 2C, NM-B W/G, CU. 'S-4K._ SCOTT A. GURNEY #PV-0117719-015866 ADJ. MODULE VMP @ ASHRAE 2% AVG. HIGH TEMP 29.7 CONDUCTOR AMP. RATING @60°C = 30 A ION DEVELOPER,LLC # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED 4801 N UNIVERSITY AVE#900 PROVO, UT INVERTER SPECIFICATIONS AMB TEMP.. AMP. CORRECTION = NOT APPLIED 84604 ENPHASE IQ8PLUS 72 2 US888.4604 74 TYPE MICROINVERTER ADJUSTED AMPACITY COMPLIANCE (A) = 30 > 12.0 OK MAX. OR RECOMMENDED MODULE POWER (W) 440 RACEWAY SIZE / TYPE = FREE AIR DAVID STANLEY CONRAD UM INPUT DC OPEN-CIRCUIT VOLTAGE (VOC) 60 C-ELECTRICAL CONTRACTOR MINIMUM START VOLTAGE (V) 30 CI524 MAXIMUM START VOLTAGE(V) 58 MAXIMUM INPUT CURRENT (ISC) (A) 15 CEC PEAK OUTPUT POWER (W) 298 JUNCTION BOX TO COMBINER BOX (3) MAX. CONTINUOUS OUTPUT CURRENT (A) 1.21 MAX INVERTER OUTPUT CIRCUIT CURRENT = 9.7 A AC z o NOMINAL (L-L) OUTPUT VOLTAGE 240 MAX CURRENT X125% = 12 A AC Q N CEC WEIGHTED EFFICIENCY (%) 97.0% PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) N CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG THHN / THWN, CU. o u U.SYSTEM ELECTRICAL SPECIFICATIONS CIR I CONDUCTOR AMP. RATING @60°C = 35 A Q = ' Q NUMBER OF MODULES PER CIRCUIT 8 # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED -4 °O N DC POWER RATING PER CIRCUIT (STC)(W DC) 3040 AMB. TEMP. AMP. CORRECTION = NOT APPLIED Q r, v) __ Q TOTAL MODULE QUANTITY 8 PV MODULES ADJUSTED AMPACITY COMPLIANCE (A) = 35 > 12.0 OK o °' _ 5. U STC DC POWER RATING OF ARRAY 3040W DC RACEWAY SIZE / TYPE = 3/4 IN. EMT w Z I- < coo coo w Q Q v INVERTER OUTPUT CIRCUIT CURRENT(A AC) 9.68 CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.063 IN."2 Q T <9 o C23- N ., 125% INVERTER OUTPUT CIRCUIT CURRENT(A AC) 12.1 CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN."2 Ex o H ix m N C Y CIRCUIT OCPD RATING (A) 15 % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE I) = 40% > 12% OK u_ w o Q i o • Z w m J z , N COMBINED INVERTER CONTINUOUS OUTPUT CURRENT 9.68A ACZ - PV POWER PRODUCTION SYSTEM OCPD RATING (X125%) 15A COMBINER BOX TO MAIN PV OCPD (10) H w c ^ o MAX. ARRAY STC-AC POWER (W) • 2384W AC (STC) COMBINED INVERTER CONTINUOUS OUTPUT CURRENT = 9.7 A AC N Y `n I M MAX. ARRAY CEC-AC POWER (W) 2711W AC (CEC) MAX CURRENT X125% = 12.0 A AC DRAWING BY PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) ENPHASE ENERGY AC VOLTAGE RISE CALCULATIONS DIST (FT) COND. VRISE(V) VEND(V) %VRISE CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG THHN / THWN, CU. VRISE SEC. I (MICRO TO JBOX) * 28.8 12 Cu. 1.1 241.1 0.46% CONDUCTOR AMP. RATING @75°C = 35 A DATE I9-AUG-2022 VRISE SEC. 2 (JBOX TO COMBINER BOX) 40 10 Cu. 0.9 240.9 0.39% # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED VRISE SEC. 3 (COMBINER BOX TO P01) 10 10 Cu. 0.2 240.2 0.10% AMB. TEMP. AMP. CORRECTION = NOT APPLIED PROJECT ID TOTAL VRISE 2.3 242.3 0.95% OK ADJUSTED AMPACITY COMPLIANCE (A) = 35.0 > 12.0 OK 007NPW * 8 MICROINVERTER MAX SUB-BRANCH CIRCUIT SIZE TO COMPLY WITH VRISE CALCULATIONS. RACEWAY SIZE / TYPE = 3/4 IN. EMT CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.084 IN."2 SHEET NAME CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN."2 ELECTRICAL CALCS. % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE I) = 40% > 16% OK SHEET NUMBER REVISON E-7 0 ELECTRICAL FIELD-APPLIED HAZARD MARKINGS AT EACH PV SYSTEM DISCONNECTING MEANS. SIGN LOCATED ON OR NO MORE THAN 3 PHOTOVOLTAIC SYSTEM A [NEC 690.54, NEC 690.13(B)] RAPID SHUTDa:JN F FT FROM THE RAPID SHUT DOWN A AC DISCONNECT A SWITCH FOR DISCONNECT SWITCH [NEC 690.56(C)]. ION RATED AC OUTPUT CURRENT 9.7A SOI AR DV :- YSTPM NOMINAL OPERATING AC VOLTAGE 240 V ~ FOR BUILDINGS WITH PV SYSTEMS. TO CONFIDENTIAL-THE INFORMATION SOLAR PV SYSTEM EQUIPPED G BE LOCATED AT EACH SERVICE HEREIN CONTAINED SHALL NOT BE USED FOR PV DISCONNECTING MEANS WHERE ALL WITH RAPID SHUTDOWN EQUIPMENT LOCATION TO WHICH THE PV FOR THE BENEFIT OF ANYONE EXCEPT ION AWARNING B TERMINALS OF THE DISCONNECTING MEANS TURN RAPID SHUTDOWN SYSTEM IS CONNECTED. [NEC DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO ELECTRIC SHOCK HAZARD MAY BE ENERGIZED IN THE OPEN POSITION. sYWTCHTOTHE 690cnts .56(C)] OTHERS OUTSIDE RECIPIENTS EXCEPT IN [NEC 690.13(B), NEC 705.22] T DOWN POSITION TO PV Al eeIA TERMINALS ON THE LINE AND SHUT ORGANIZATION,WITH THE SALE AND USE OF THE LOAD SIDES MAY BE ENERGIZED SHOCK HAZARD AND REDUCE RESPECTIVE EQUIPMENT,WITHOUT THE IN THE OPEN POSITION _ —IN THEWRITTEN PERMISSION OF ION DEVELOPER, LLC. AT EQUIPMENT CONTAINING OVERCURRENT A WARNING J PERMANENT DIRECTORY TO BE LOCATED AT /\WARNING C DEVICES IN CIRCUTS SUPPLYING POWER TO A MAIN SERVICE EQUIPMENT DENOTING THE NABCEP BUSBAR OR CONDUCTOR SUPPLIED FROM POWER TO THIS BUILDING IS ALSO SUPPLIED LOCATION OF THE PV RAPID SHUTDOWN SYSTEM DUAL POWER SUPPLY MULTIPLE SOURCES. [NEC 705.12(C)] FROM A ROOF MOUNTED SOLAR ARRAY. DISCONNECTING MEANS IF SOLAR ARRAY RAPID CERTIFIED SHUT DOWN DISCONNECT SWITCH IS NOT SOURCES:UTILITY GRID AND SOLAR ARRAY RAPID SHUTDOWN GROUPED AND WITHIN LINE OF SITE OF MAIN PV INSTALLATION PV SOLAR ELECTRIC SYSTEM ISLOCATED SERVICE DISCONNECTING MEANS. [NEC 705.10, PROFESSIONAL NEC 690.56(C)(I)] . ,..�/ - SCOTT A. GURNEY / #PV-0117719-015866 PLAC D ADJACENT TO PV TEM PLUG-IN I ITYPES BREAKER TO A BUSBAR FORA LOAD ®WARNING SOLAR ARRAY IRAPID OSHUTDOWN LOCATEDWIITC AT 4801 N UNIVERSITY AVEE#900CPROVO, UT �VIlAFiNINI DI DENOTING THE LOCATION OF THE SERVICE 84604 SIDE CONNECTION. POWER SOURCE [NEC 705.12(B)(3)(2)] POWER TOTHI36UILDINGISALSO EQUIPMENT LOCATION IF SOLAR ARRAY RAPID 888.781.7074 I OUTPUT CONNECTION SUPPLIED FROM MAINDISTwsuTloN SHUT DOWN DISCONNECT SWITCH IS NOT DO NOT RELOCATE THIS UTIUTY DISCONNECT LOCATED GROUPED AND WITHIN LINE OF SITE OF MAIN DAVID STANLEY CONRAD OVERCURRENT DEVICE SERVICE DISCONNECTING MEANS. [NEC 705.10] C-ELECTRICAL CONTRACTOR CI524 a El W z o El El © a ElQ CV UTILITY © El 0(E) CD METER (E)MAIN SERVICE PANEL Q = COMBINER BOX U diw ° " th AWINNO A �� `-� NI to WC N . • iI w o J (n Q AVARNING c mwARNwo 0 Q 0 Z co co W<1— a c - I . W W CD O 0 PO L.)�9C�4" N 2 W W N 0PV SYSTEM Q O CD Q U DISCONNECT(S)TO LL_ Cl) 0 Q I O N (N)PV BREAKER PV INVERTER Z } J cn z OUTPUT CIRCUIT(S) W = LI) < N W CD • co°�° _� Q co O CD O N rnwsr� r O 0 vI I'- il ) ws�� EG< t DRAWING BY EIE ENPHASE ENERGY DATE 19-AuG-2022 Lill PROJECT ID 007NPW ALL CAUTION, WARNING, OR DANGER SIGNS OR LABELS SHALL: SHEET NAME I, COMPLY WITH ANSI Z535.4-2011 STANDARDS. 2. BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. ELECTRICAL LABELS 3. SHALL BE OF SUFFICEINT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 4. UNLESS OTHERS SPECIFIED MINIMUM TEXT HEIGHT TO BE g (3MM). SHEET NUMBER REVISON E-9 0 s .,P. IDENTIFICATION OF POWER SOURCES A PERMANENT PLAQUE OR DIRECTORY TO BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION ION DENOTING THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. FOR THE BUILDING OR STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. ALL MARKING TO COMPLY WITH 110.21 (B). (NEC 705.10) CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE \J /\ `J T O \ e / T I WRITTEN PERMISSION OF ION DEVELOPER, /!�\ I V I LLC. SOJCFS OF �' O W - Re 1 ABCEP POWER TO THIS BUILDING IS SUPPLIED FROM THE CERTIFIED FOLLOWING SOURCES WITH DISCONNECTS LOCATED PV INSTALLATION PROFESSIONAL AS SHOWN : cam. / I SCOTT A. GURNEY UTILITY SERVICE DISCONNECT 0 �l #PV-0117719-015866 ION DEVELOPER, LLC L1J 4801 N UNIVERSITY AVE #900 PROVO, UT z 84604 a PV ARRAY / 888.781.7074 _I DAVID STANLEY CONRAD C-ELECTRICAL CONTRACTOR 0 Q Li j o C1524 I LJJ j O= ❑ LL m Q / O O m m m Z ❑ o w H I__ z o (/) m IS/ El m me, Q LLJ ( J N o N 1 ❑ 0 V Q = 1 V w N ai CO N / \ 0< (,,,_j Os _J u) __ < — (�) (M) 0 w w o Q K) = CD N UTILITY SERVICE METER o o o a a o RAPID SHUTDOWN AC z } o cL J Ni - I DISCONNECT SWITCH w H < ( w o DRAWING BY ENPHASE ENERGY DATE 19—AUG-2022 PROJECT ID 007NPW SHEET NAME ELEC. DIRECTORY SHEET NUMBER REVISON E—IO 0