Loading...
HomeMy WebLinkAboutPlans 4 PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 35 MODULES-ROOF MOUNTED - 12.775 kW DC, 12.503 kW AC, 13226 SW CHELSEA LOOP, TIGARD, OR 97223 infinityso�ar PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SITE DETAIL: SHEET INDEX: RECJV INFINITY MILL ME 6405 E MILL PLAIN VANCOUVER WA 98661 SYSTEM SIZE: 12.775 kW DC UTILITY: PORTLAND GENERAL ELECTRIC PV 0.0: GENERAL NOTES AND PROJECT DATA DS 09: RACKING-DATA SHEET PHONE:1-800-818-0598 12.503 kW AC MSP: EXISTING 200A WITH 200A MAIN BREAKER PV 1.0: PLOT PLAN DS 10: MOUNTING-DATA SHEET JUN 22 2022 INFINITYSOLAR.COM MODULE TYPE&AMOUNT: (35)SUNTECH STP365S-B6OIWNHB ROOF MATERIAL: COMPOSITE SHINGLE PV 1.1: SITE PLAN DS 11: RACKING-GROUNDING MODULE DIMENSIONS: (LIW/H)69.1"140.9"11.4" ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) PV 1.2: ROOF SECTION DS 12: RACKING-CERTIFICATION CITY OF TIGARD REVISIONS INVERTER: (07)HOYMILES HM-1500N MICROINVERTERS RISK CATERGORY I: 100 S 1.1: MOUNT DETAILS BUILDING DIVISION Description Date Rev (03)HOYMILES HM-700N MICROINVERTERS RISK CATEGORY II: 110 E 1.1: 3-LINE DIAGRAM (01)HOYMILES HM-350N MICROINVERTER RISK CATEGORY III-IV: 115 E 1.2: NOTES INTERCONNECTION METHOD: LINE SIDE TAP E 1.3: WARNING LABELS AHJ: CITY OF TIGARD RACKING: IRONRIDGE RACKING SYSTEM FOR COMP ROOF DS 01: PV MODULE SPECIFICATION SHEET GOVERNING CODES: ARRAY AREA: 19.63 SOFT x 35=687.1 SOFT DS 02: MICROINVERTER SPECIFICATION SHEET 2010 OREGON SOLAR INSTALLATION SPECIALTY CODE LIABILITY DS 03: MICROINVERTER SPECIFICATION SHEET Signature with Seal DS 04: COMBINER PANEL CERTIFICATION 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) The City of Tigard and its a 2021 OREGON ELECTRICAL SPECIALTY CODE(2020 NEC) employees shall not be approved plan y 7 UP DS 05: AC DISCONNECT UL CERTIFICATION ,. o 2014 OREGON FIRE CODE(2012 IFC) R► DS 06: AC DISCONNECT UL CERTIFICATION responsible for discrepancies ..hall be On iob s gn. DS 07: JUNCTION BOX UL CERTIFICATION PHOTOVOLTAIC NOTES: which may appear herein" DS 08: WIRING SPECIFICATION = U Project Name& 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING .,' G a elsea oop ' $♦ Address DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK SYSTEMS. -. 'i Tigard I s 97,223,USA i,' en + UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING r a y; PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) CONSIDERATION OF a^P AND r^P BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE $ 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC , . *: THREAD-LESS COMPRESSION TYPE. LATERAL FORCE DETERMINATION. ` 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB w 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. r DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR p y°. 0 JO N WITHSTAND THE WEATHER. DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE "' 1' U) Q ui 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE G ° W W rn ~ Q APPROPRIATE WATER RUN OFF. AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A x 3i-, rn Z W Ct 0 Mo J 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. ` ,; i Z = - BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ., $ Q 0 v 2 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. \ > co < W W 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01,310.8 D) VALIDITY OF PERMIT 2 \\ SATELLITE VIEW 0 N z APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE Lu N 00 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE DC SIDE OF THE SYSTEM.(NEC 250.97) ' THE ISSUANCE OF A PERMIT ' PV 0.01 SCALE:NTS WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF BASED ON CONSTRUCTION MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34) SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) DOCUMENTS AND OTHER 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) DATA SHALL NOT PREVENT d u UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(E) THE CODE OFFICIAL FROM %NA, THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, i4cri ,}¢ REQUIRING THE CORRECTION cost c hvie6 l MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND(NECE 690.35(F)) A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED OF ERRORS. ORSC 105.4 ; � Sheet Name 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER FROM ANY PHYSICAL DAMAGE. NEC210.5. "``ut 'ar1 't e GENERAL NOTES 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. / ` a�.t 0 r ' AND PROJECT 13. UIPMENT ALL BE AT T NEMA 3R THER DO 14.ALL SPEOCIFIEQD WIRING IS BASEDON THE USE OF COPPER RATED. ENCLOSUURES TO HE FIRST ACCCESOT ENTER THE SIBLE DC DISCONINEING OR ARE RUN IN METALLIC ECTING MEANS PER NEC 690.31 RACEWAYS 9 690.31(E) OFFICE COPY , r,-,�„, -r DATA Tigard 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, -` _ Sheet Size COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S z lei-sea i Loop, 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE INSTALLATION INSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). T 1� T ' c >--7'1 :is ANSI B CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE CITY OF TJ.GI D 4 a ,9. ` s'' 1 1" X 17" 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL LAMC 93.110.3(B). REVIEWED FORF05,CODE COMPLIANCE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE sr,cause st V,M' ,„n4ia Sheet Number APPROPRIATE. LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. Approved: [VI 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS, ,I, SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY ii-° `• [ 1 l e D',c,-i t PV 0.0 MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN REMOVABLE FASTENERS. ,5�2022 THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THEPCrnllt#: REQUIRED BY THE ARCHITECT/ENGINEER. BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAI(Address. 1•; 5'\-\ � �0. ,,7:.,1r-,�5, 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 11V OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING SU ite #: -' 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING `3`) `b 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE ROOF-COVERING MATERIAL. By: kk Date: 3 22-- GENERAL NOTES AND PROJECT DATA 40.ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 1/2"OFF THE ROOF SURFACE. / 3 VICINITY MAP PV 0.0 PV 0.0 SCALE:NTS PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 35 MODULES-ROOF MOUNTED - 12.775 kW DC, 12.503 kW AC, 13226 SW CHELSEA LOOP, TIGARD, OR 97223 infinity solo INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: •ROOF ACCESS POINT 6405EMILLPLAIN VANCOUVER WA 98661 ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS PHONE:1-800-818-0598 SYSTEM SIZE: 12.775 kW DC THAT REQUIRE THE PLACEMENT OF GROUND LADDERS INFINITY SOLAR.COM 12.503 kW AC OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND MODULE TYPE&AMOUNT: (35)SUNTECH STP365S-B60/WNHB LOCATED AT STRONG POINTS OF BUILDING REVISIONS MODULE DIMENSIONS: (L/W/H)69.1"/40.9"11.4" CONSTRUCTION IN LOCATIONS WHERE THE ACCESS INVERTER: (07)HOYMILES HM-1500N MICROINVERTERS ROOF#3 POINT DOES NOT CONFLICT WITH OVERHEAD Description Date Rev (03)HOYMILES HM-700N MICROINVERTERS (02)SUNTECH STP365S-B6OIWNHB OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. (01)HOYMILES HM-350N MICROINVERTER SLOPE:23° AHJ: CITY OF TIGARD N AZIM.:03° ewrrr ROOF#1 9 (26)SUNTECH STP365S-B60/WNHB Signature with Seal PROPERTY LINE SLOPE:23° _ _ _ _ AZIM.:93° EXISTING INTERIOR MAIN SERVICE PANEL TIED 1 90�-2" I TO EXTERIOR UTILITY METER#25 063 525 I - - — --- _ _-- -- 1 -- _ r,4661,, 1 cj z Project Name& Address w 1� 19'-11" 111111fri°1111 ------_ Io II Q. 11 1 w 0 CD 11 ��� < N � I 0 a) DRIVEWAYW w � ti Q 0 rz a' 2 z --- 1 J z = � 0 -i ;,r Il m loomw iI J (/) Q LLI LL1 111111 GARAGE ------ C� ww co j O 13'-9" ---J `* u_ LLl 1Ell 1 zo FP = I 1 i o U MAIN HOUSE Ef_ _inI (I) IIMIN EN 1I Cfl 1 N Sheet Name II PI PLOT PLAN zl I1 Sheet Size tii ~ I ANSI B �- _ - - _ _ 1 11" X17" 1 90'-2" _ _ _ — — — Sheet Number PROPERTY LINE PV 1 .0 FENCE ROOF#2 (07)SUNTECH STP365S-B60/WNHB SLOPE:23° AZIM.:183° ROOF ACCESS POINT 1 PLOT PLAN NEW PV AC DISCONNECT VISIBLE, LOCKABLE, LABELED DISCONNECT PV 1.0 SCALE:3/32"=1'-0" WITHIN 10' OF UTILITY METER PHOTOVOLTAIC SYSTEM SPECIFICATIONS: NOTE : ROOF ATTACHEMENT:- SUNMODO NANO SYSTEM LEGEND SYSTEM SIZE: 12.775 kW DC ATTIC RUN-YES C DECK MOUNT OPTION EXISTINGINTERIORMAINSERVICEPANEL&POINT 12.503 kW AC ATTIC FAN-NO M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY MODULE TYPE&AMOUNT: (35)SUNTECH STP365S-B60/WNHB SHUTDOWN -NO infinity solar METER#25 063 525 MODULE DIMENSIONS: (L/W/H)69.1"/40.9"/1.4" INVERTER: (07)HOYMILES HM-150ON MICROINVERTERS NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS AC' LOCATED WITHIN 10'FROM THE UTILITY METER 6405 E MILL PLAIN (03)HOYMILES HM-700N MICROINVERTERS VANCOUVER WA 98661 PHONE:1-800-818-0598 (01)HOYMILES HM-350N MICROINVERTER INFINITY SOLAR.COM AHJ: CITY OF TIGARD C NEW DEDICATED PV SYSTEM COMBINER PANEL. VISIBLE, LOCKABLE, LABELED DISCONNECT EXISTING INTERIOR MAIN SERVICE PANEL REVISIONS &POINT OF INTERCONNECTION.TIED TO 35 NEW SUNTECH STP365S-B60/WNHB MODULES Description Date Rev WITHIN 10'OF UTILITY METER EXTERIOR UTILITY METER#25 063 525 11 WITH NEW(07)HOYMILES HM-1500N,(03)HOYMILES HM-700N&(01)HOYMILES HM-350N INVERTERS NEW PV AC DISCONNECT GROUPED BILL OF MATERIALS WITH SERVICE EQUIPMENT(VISIBLE, NUMBER OF MODULES 35 SUNTECH STP365S-B60/WNHB LOCKABLE,LABELED) =FIRE PATHWAY 07 HOYMILES HM-1500N NEW AC COMBINER PANEL Signature with Seal NUMBER OF INVERTER 03 HOYMILES HM-700N ❑O =ROOF OBSTRUCTIONS 01 HOYMILES HM-350N • • =ATTACHMENT POINTS COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER 2❑ 816L125RP �/ � �// AC DISCONNECT 1 100A FUSIBLE AC DISCONNECT,240V RooF#03 ¢ 36"FI•E S =RAFTER NUMBER OF ATTACHMENTS 86 SUNMODO NANO DECK MOUNT 20'-4" ""' ''"yz.� i � M Project Name& 6'11" 4'-11" w ♦ i :� f- /� -- Address .' r�i-� ice., =RACKING SYSTEM RAILS 19 IRONRIDGE XR10 RAIL-168"(14')SECTION 1 I I I %/���f I i �. r ��� �f'/ - = ATTIC RUN RAIL SPLICE 10 SPLICE KIT I i '//Q/�7//, " ��/��I/ jam �/,/,, MID CLAMPS 52 MID CLAMPS/UFOI 1"/‘ �/ /� ' 'I j ✓ j%`� j • -__ / ���i:' j /� =CONDUIT ATTIC RUN JUNCTION BOX LLI END CLAMPS 36 END CLAMPS I STOPPER SLEEVE o ���� ` GROUNDING LUG 9 GROUNDING LUG . / '1 - e ___/ �j /%' • ROOF SECTIONS I I I IQ I 1 y% / � i� �/����/�/ z 0 Q s � % �` /, CIRCUITS I I 1 I �� �/ /�/// / j ^ o J N O I P I I �� ✓%/////%////. I I ����% %%/ ROOF#01 MODULE-26 to < ti `' / _ /�j �%/ �j�% j� SLOPE-23° w w o) Q �/ / CIRCUIT#1 12 MODULES WITH 03 MICROINVERTERS ;A.,/ y�`� � /�,, /,1 d/ tz w z I 1 4 _ �/ %j �j/ %� �` /� AZIMUTH-93° w ch ���;,`-- 4l,4 —ice :---- '''/,� MATERIAL-COMPOSITE SHINGLE z = O "8 / � CIRCUIT#3 11 MODULES WITH 05 MICROINVERTERS CIRCUIT#2- 12 MODULES WITH 03 MICROINVERTERS o 1 �� / ��� ���� � �� '� 0 RAFTER SIZE&SPACING-2°x8°@ 24°O.C. > Y ////� 1 /' ,` �� ./ %/ 0////� .i- Q ROOF#02 MODULE-07 p CD z -,/y.-iiv/, ,, — / /// -,; SLOPE-23° w ( � O C� 'y %'/j ' N Aif*7�/ Q AZIMUTH-183° < cal MODULE, ARRAY WEIGHT(LOAD i��A. Ar J Jr if t, LLJ MATERIAL-COMPOSITE SHINGLE - ���//i%%/ ���!. RAFTER SIZE&SPACING-2"X8"@ 24"O.C. CALC'S) ❑ jj��� %�%�� �/` 0 0 ROOF#03 MODULE-02 Number of Modules 35 I --- /%0i/! 1,;/ _ p �/ Li. L j 1 SLOPE-23° Module Weight 44.8 LBS OI , o = AZIMUTH-03° 1 % j� MATERIAL COMPOSITE SHINGLE Total Module(Array)Weight 1568.00 LBS - 0 RAFTER SIZE&SPACING-2"X8" 24"O.C. o Number of Attachment point 86 I I I 1 ; to"- '', .��/� IJ Sheet Name Mounting System Weight 1.5 LBS I 'j/�'�/�i• - /�",���_ (Per Module) ��i /j / ��� SITE PLAN Mounting System Weight 129.00 LBS I i / /;f/ ' �' /// i, CD / + s %i I' i'T' ' T N Total System Weight I I I /.�d,�e I � .• y g 1697.00 LBS r� / N Sheet Size (Module Weight+Mounhng System WegM) /. //✓//,s v, Weight at Each Attachment Point % // ' //����/�° g 18.23 LBS % ��'/� l ANSI B (Array Weight/Number of Attachment Point) I I % S///�! ' A„/ „ 1 ' - I � II II I ''/ �O% ' • I 1 I I 11 X 17 Module Area(69.1"x40.9") 19.63 SqFt , i j /� , '�/is- // /�/ Total Array Area 686.92 SqFt y'�� %�/ ✓�/%%%�///,, �'I i Sheet Number I Distributed Load 2.36 Per SqFt �— 7 7 13'-10" -----1-- etw rNpa (Total System WegM/TotalArreyArea) `- 14'-1" �� ` Total Roof Area 1890 SqFt ROOF#02 PV 1.1 Total Percentage or Roof Covered 36.35% NEW PV ATTACHMENTS Total Array Area/Total RoofArea)'/00 AT 4'-0"0.C. _ �1 SITE PLAN PV 1.1 SCALE:1/8"=1'-0" ROOF 1 0 infinity solar INFINITY HOME SOLUTIONS r 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM '` ` REVISIONS Description Date Rev 24° Signature with Seal Project Name& Address \--- EXTERIOR BEARING WALL EXTERIOR BEARING WALL---/i - w U 0_ Z p w o O N 0 w w N- Q J7 IZ ROOF 2 ROOF 3 Q Z = - � — o � 0zw w co O (N)PV MODULE Q cA _ Sheet Name ROOF SECTION Sheet Size ANSI B 11" X17" Sheet Number PV 1.2 \-- EXTERIOR BEARING WALL EXTERIOR BEARING WALL-/i ( fROOFSECTION -� PV 1.2 . GENERAL STRUCTURAL NOTES: 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE L) ROOF FRAMING USING THE IRONRIDGE RACKING infinity solo SYSTEM WITH SUNMODO NANO DECK MOUNT ATTACHMENTS. THE MOUNTING FEET ARE TO BE INFINITY HOME SOLUTIONS PV MODULE 6405E MILL PLAIN SPACED AS SHOWN IN THE DETAILS, AND MUST SEE(2/S 1.1) FOR VANCOUVERWA98661 BE STAGGERED TO ADJACENT FRAMING ENLARGED VIEW 11111111111111111111 PHONE:1-800-818-0598 MEMBERS TO SPREAD OUT THE ADDITIONAL INFINITY SOLAR.COM LOAD. 2. UNLESS NOTED OTHERWISE, MOUNTING / REVISIONS ANCHORS SHALL BE 5/16" LAG SCREWS WITH A Description Date Rev MINIMUM OF 2-1/2" PENETRATION INTO ROOF / RS @2q"OC FRAMING. / !, 2Xa,RpFSE 3. THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THE ,, ROOF FRAMING SYSTEM. (E) COMPOSITE SHINGLE ROOF 4. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER NEW PV SYSTEM. Signature with Seal 5. GROUND SNOW LOAD=N/A PSF \ / 6. WIND SPEED=110 MPH 7. EXPOSURE CATEGORY=C \ 8. RISK CATEGORY=II Project Name& Address (1) ATTACHMENT DETAIL (SIDE VIEW) s 1.1 SCALE:NTS LU Z Q rn Lii IRONRIDGE MID CLAMP/END CLAMP o o co o ti - I II� PV MODULE � � O .11_- z IRONRIDGE XR10 RACKING SYSTEM Qo =' a o IX r > Q Ili w SS SERRATED FLANGE NUT Q (ID o SS SERRATED T-BOLT a ��.5 - SUNMODO NANO DECK MOUNT k SEALING WASHER './_ k 0.261D X 0.50 X 0.125 ,« Sheet Name - 1/2" OSB SHEATHING itio MOUNT DETAIL (E)COMPOSITE SHINGLE ROOF Sheet Size ANSI B 11" X 17" Sheet Number (4)- SELF DRILLING SCREW,#6.3 x 76. S 1.1 SEALING WASHER 0.261D x 0.50 x 1.25 PENETRATE INTO DECKING 2 ATTACHMENT DETAIL ENLARGED VIEW s1.1 SCALE:NTS PV MODULE RATING @ STC MICROINVERTERS SPECIFICATION Rooftop conductor ampacities designed in compliance with 120% RULE �t<�`��E MANUFACTURER SUNTECH STP365S-B60/WNHB MICROINVERTER MAKE HOYMILES art. 690.8,Tables 310.15(B)(2)(a), 310.15(B)(3)(a), V MICROINVERTER MODEL NO. HM-1500N 310.15 B 3 c , 310.15 B 16 , Chapter 9 Table 4, 5, &9. BUS BAR RATING X 120%) -MAIN BREAKER RATING infinity MAX.POWER-POINT CURRENT(IMP) 10.68 AMPS MAXIMUM AC OUTPUT 1,438W ( )( )O ( )( ) p = MAX. PV OCPD '' MAX.POWER-POINT VOLTAGE(VMP) 34.2 VOLTS MAX INPUT VOLTAGE 60 V Location specific temperature obtained from ASHRAE 2017I NFINITY HOME SOLUTIONS OPEN-CIRCUIT VOLTAGE(VOC) 41.7 VOLTS MAX AC CURRENT 5.99 A data tables (200A x 120%) - 200 = 40A 6405E MILL PLAIN VANCOUVER WA 98661 MICROINVERTER MODEL NO. HM-700N RECORD LOW TEMP -8°C PHONE:1-800-818-0598 SHORT-CIRCUIT CURRENT(ISC) 11.22 AMPS INFINITY SOLAR.COM Si; NOM.MAX.POWER AT STC(PMAX) 365 WATT MAXIMUM AC OUTPUT 696 W AMBIENT TEMP(HIGH TEMP 2%) 32°C THIS PANEL IS FED BY MULTIPLE SOURCES MAX INPUT VOLTAGE 60 V (UTILITY AND SOLAR) REVISIONS MAX.SYSTEM VOLTAGE 1500V MAX AC CURRENT 2.90 A CONDUIT HEIGHT 0.5" Descripton Date Rev VOC TEMPERATURE COEFFICIENT -0.304%/°C MICROINVERTER MODEL NO. HM-350N ROOF TOP TEMP 54°C AC OUTPUT CURRENT 52A MAXIMUM AC OUTPUT 349 W MAX INPUT VOLTAGE 60 V CONDUCTOR TEMPERATURE RATE 90°C NOMINAL AC VOLTAGE 240V VISIBLE, LOCKABLE, LABELED DISCONNECT MAX AC CURRENT 1.45 A WITHIN 10'OF UTILITY METER NOTE : Signature with Seal ATTIC RUN -YES POINT OF INTERCONNECT,SUPPLY SIDE (35) SUNTECH STP365S-B60/WNHB SHUTDOWN-NO EXISTING 240V/200A BUS BAR RATING, (07) HOYMILES HM-1500N INVERTERS MAIN SERVICE PANEL,SINGLE PHASE, 03 HOYMILES HM-700N INVERTERS WITH A 200A MAIN BREAKER ( ) UTILITY COMPANY-PORTLAND (01) HOYMILES HM-350N INVERTERS GENERAL ELECTRIC Project Name& Address BRANCH 1-12 MODULES WITH 03 MICRO INVERTERS UTILITY METER#25 063 525 ""' 1 1 I C EXISTING II =■■..■ BI-DIRECTIONAL r-A CCCCCC :mum ___-- I__-- CC;CC CCCCCC UTILITY METER, M (N)BLADE TYPE 1-PHASE,3W, �_� w L _ -L L L L — , L L L� _ __I J FUSIBLE AC DISCONNECT 120V/240V Z 0 0 1N iN a (N)125A SOLAR LOAD CENTER, NEMA 3R 100A-2P 120/240VAC 0 -' o L 240V,3W,1-PHASE (VISIBLE,LOCKABLE,LABELED) cn w ti ti Q BRANCH 2-12 MODULES WITH 03 MICRO INVERTERS o o a — —i ioor ■■■i — ■■w■■ ii■i LINE SIDE TAP 200A J I EMU I �CCCII I 70A FUSES USING IPC Eo z = 0 0 S■■■■ EMI I ■■■■■ Z Lp — m■■■ ■■ OM I ■ (E)LOADS 0 Q ■..■■■I ■ r . C . (N)JUNCTION BOX Q cL w w m.] �� > C ■o■ ■ o■a■ �■mC C �. ° o,o FIRM EMU __ __ r ---! mom ■Ula! ! 600 V,NEMA 4 �� p CD Z { UL LISTED 25A o w N j= 0 (E)LOADS Ct Q a- /N./ /-./ 2 L, 25A / ' 17 L2 ! 25A L1 -\_,, o o pry BRANCH 3-11 MODULES WITH 05 MICRO INVERTERS ' El ■■■■■ C■■■■■ I ;■■O■ ■■■■ `----I j---- - — L2 L2 - ° ° L2 ° ICI I I I I ,' L, N N N 11 !, i ...... E I ..... ZG L2 - I c G G Sheet Name ---- _-- 1 tl■■■■ _ ■■■■ _. L——— ——— ——— -._ �L— C __ C , ICC.... { L�_ —_I L_ _ _LI = _J L L_ — J L I 3-LINE 1� /� 1N a ;  DIAGRAM L O O O EXISTING GROUNDING ELECTRODE SYSTEM Sheet Size ANSI B WIRE MAX PARALLEL C.0 PV CURR. MAX. TOTAL CONT. CURR WIRE SIZE\TYPEWMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 11" X 17" TAG# DEVICES RATING MULT CURR CURR X 125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) Sheet Number O3 x 5.99 x N/A = 17.97A 17.97A 22.46A #10\THWN \40A @90°C 25A 2 TRUNK IN AIR CABLE 0.96 x 1.00 x 40A 38.40A 17.97A #6 AWG 20 0.31 E 1 .1 O = 1.28 3 x 5.99 x N/A17.97A 17.97A 22.46A #10\THWN\40A @90°C 25A 6 3/4" EMT 0.96 x 0.80 x 40A 30.72A 17.97A #8 AWG 50 0.78 <2 x 7 x 5.99 x N/A = 41.93A O3 x 2.90 x N/A = 8.70A 52.08A 65.10A #6 \THWN\75A @90°C 70A 3 3/4" EMT 0.96 x 1.00 x 75A 72.00A 52.08A #8 AWG 10 0.19 1 x 1.45 x N/A = 1.45A SITE NOTES: GROUNDING NOTES: � . '1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH infinit 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE. UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM INFINITY HOME SOLUTIONS 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, NEC TABLE 250.122. 6405E MILL PLAIN VANCOUVER WA 98661 OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES PHONE:1-800-818-0598 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). INFINITY SOLAR.COM ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 690.45 AND MICROINVERTER MANUFACTURERS INSTRUCTIONS. REVISIONS ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN Description Date Rev INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE BUILDING OR STRUCTURE. NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION EQUIPMENT LOCATIONS: REQUIREMENTS. 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT Signature with Seal 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES ANOTHER MODULE. 310.15(B)(2)(A)AND 310.15(B)(3)(C). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] ACCORDING TO NEC 690.34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 Project Name 8 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A Address WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC AND AHJ. APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS USAGE WHEN APPROPRIATE. w DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: U a 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS w 0 c.-, o STRUCTURAL NOTES: OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE Q 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS). w rn Q CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE w 0 m '- SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH z o a BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAILS 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID MANUFACTURER'S INSTRUCTIONS. SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY ocf) 0 z 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). w cC ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND Q REQUIREMENTS. 240. 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ 5. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. FUSES IN ACCORDANCE WITH NEC 110.3(B). 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN ACCORDING TO NEC 690.11 AND UL1699B. POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED Sheet Name AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12(B)] NOTES WIRING&CONDUIT NOTES: 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)]. Sheet Size CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT ANSI B REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED 11" X 17" 3. VOLTAGE DROP LIMITED TO 1.5%. BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)]. sheet Number SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL E 1 .2 WIRING CLIPS. RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- ACCORDING TO NEC 705.12(B)(2)(3)(C). BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL-WHITE OR GREY 5. FEEDER TAP INTERCONECTION(LOADSIDE)ACCORDING TO NEC 705.12(B)(2)(1) IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH BE MARKED ORANGE[NEC 110.15]. SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)]. - AWARNING ®WARNING DUAL POWER SOURCE ELECTRICAL SHOCK HAZARD SECOND SOURCE IS PHOTOVOLTAIC SYSTEM infinity solar WA R N I N LABEL LOCATION: INFINFY HOME SOLUTIONS TERMINALS ON BOTH LINE AND - A PRODUCTION/NET METER(BI-DIRECTIONAL) ' POWER SOURCE OUTPUT405U ERWA98 LOAD SIDES MAY BE ENERGIZED NEC:NEC:2o2o VANCOUVERWA98661 IN THE OPEN POSITION NNECTION.DO NOT RELOCATE NEC 690.59,705.12(D)(3) PHON:1-8Y0-818-09 THIS OVERCURRENT DEVICE. LABEL LOCATION: LABEL LOCATION: REVISIONS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE MAIN SERVICE DISCONNECT . ENERGIZED IN THE OPEN POSITION,A WARNING SIGN SHALL BE .. NEC:2020,705.12(B)(3)(2) Description Date Rev MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. PER CODE(S):NEC 2020: NEC 706.15(C)(4)and NEC 690.13(B) L MAIN PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM AC DISCONNECT YSTEM DISCONNECT RATED AC OPERATING CURRENT 52.08 AMPS Signature with Seal p - AC NOMINAL OPERATING VOLTAGE 240 VOLTS /\WARN I NG LABEL LOCATION: MAIN SERVICE DISCONNECT.NEC 2020.690.13(B) LABEL LOCATION: THIS EQUIPMENT FED BY MULTIPLE SOURCES, —� A AC DISCONNECT,POINT OF INTERCONNECTION TOTAL RATING OF ALL OVERCURRENT DEVICES, /'1 NEC:2020 (PER CODE:NEC 690.54) EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, F Project Name& SHALL NOT EXCEED AMPACITY OF BUSBAR. Address LABEL LOCATION: PERMANENT WARNING LABELS SHALL BE APPLIED TO CAUTION . DISTRIBUTION EQUIPMENT,AC DISCONNECT A NEC:2020 PER CODE:705.12(B)(3)(3) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE w FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS z o 0 PHOTOVOLTAIC SHOWN. w o co o DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES o w 6 a � � J � �Z SOLAR PV SYSTEM O W o 0 AC DISCONNECT EQUIPPED WITH RAPID Q 0 0 v< LABEL LOCATION: et SHUTDOWN 1114;17r1 0 < z LuAC DISCONNECT U.I LLJ . 0 ZNEC:2020 Z CV(NEC 690.13(B) m OTURN RAPID _ SHUTDOWN (L � � d 2 m SWITCH TO THE O PHOTOVOLTAIC SYSTEM "OFF"POSITION TO SOLAR g SHUTDOWN PV ELECTRIC O SYSTEM AND PV PANELS —I EQUIPPED WITH - ; REDUCE WII RAPID SHUTDOWN 4 SHOCK HAZARD IN THE ARRAY J Sheet Name AT INVERTER[IFC 605.11.3.1(1)&690.56(C)] W I WARN IN G LABEL LOCATION: PER CODE:NEC 2020 = UTILITY SERVICE ENTRANCE/METER,INVERTER/DC DISCONNECT (, -- LABELS IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. I-- Sheet Size PER CODE(S):NEC 2020:ARTICLE 690.56(C) --- ill ANSI B PV ARRAY ( 11 X 17 N --m Sheet Number k NB A ©AC B 35 PV MODULES E 1 .3 I # I L _ SOLAR PHOTOVOLTAIC MAIN SERVICE I- _ -I SYSTEMS PANEL AC COMBINER PANEL (PER CODE:NEC 690) AC DISCONNECT WARNING:PHOTOVOLTAIC _ _ _ _s _ J _ 0 POWER SOURCE SOLAR PHOTOVOLTAIC UTILITY METER LABEL LOCATION: EXPOSED RACEWAY,CABLE TRAYS,JUNCTION BOX SYSTEMS ' NEC:2020,PER CODE:NEC 690.31(D)(2) (PER CODE:NEC 690) a 5 SUNTECH 5-SUNTECH infinity r_,',< : + INFINITY HOME SOLUTIONS 6405 E MILL PLAIN 3 5 5-3 6 5 Watt SIC STPXXXS-B60/Wnhb PHONE:1 8 0 818A 05 8 IJIi� Maximum Power at STC(Pmax) 365W 360W 355W Iv1I0 cel 1 PNONE 1 800AR.CO 8 989138• 944110 041 INFINITY• SOIAR.COM mrn� Optimum OperatingVoltage(Vmp) 34.2V 34.0V 33.8V B Optimum Operating Current(Imp) 10.68A 10.59A 10.51 A �I r REVISIONS 120 HALF-CELL MONOFACIAL MODULE STPXXXS B60/Wnhb Open Circuit Voltage(Voc) r 41.7V 1 41.5V 41.3V i-988. /" Plordollabet I-- B Description Dale Rev Short Circuit Current(Isc) 11.22A 11.15A 11.08A I Module Efficiency 20.0% 1 19.8% 19.5% 8-1403Sh)035: I Mpartrg slKS Operating Module Temperature -40°C to+85°C Features Maximum System Voltage 1500 V DC(IEC) Section A-A (Rear View) Maximum Series Fuse Rating 20 A A r A High module conversion efficiency W i o 0 o Signature with Seal �_ Module efficiency up to 20.0%achieved through advanced cell technology and Power Tolerance f 0/+5 W -:ti manufacturing process SIC r ad 005W moduletemperature 25"C AM-1 5 Tolerance of Pmaa tswMiwr+0 346. I 1 exo Suntech current sorting process 35113e1 1 i 1E Upto 2%power loss caused bycurrent mismatch could be diminished bycurrent 2% NMOT STPXXXS-B60/Wnhb Section B-B sorting technique to maximize system power output LL Maximum Power at NMOT(pmax) 275.5W 271.6W 268.0W ra Excellent weak light performance Optimum Operating Voltage(Vmp) 32.1V 31.9V 31.7V Project Name& a..r„a6, More power output in weak light condition,such as cloudy,morning and sunset Address Optimum Operating Current(Imp) 8.57A 8.51A 8.45A 20I0191 Lower operating temperature Open Circuit Voltage(Voc) 39.2V 39.0V 38.8V Lower operating temperature and temperature coefficient increases the power Short Circuit Current(Isc) 9.05A 9.00A 8.94A Note:mm(inchj output NMOT.inadsosce BOO Wsm-,arnlatent teo tn.,::it.:,c 201C,AM-i 5.Bond speed I m/s. -s Extended wind and snow load tests LL1 Module certified to withstand extreme wind(2400 Pascal)and snow loads Z Wp o (5400 Pascal)* WW 0 cco o e Withstanding harsh environment Current-Voltage&Power-Voltage Curve(3655) w Q 'n Reliable quality leads to a better sustainability even in harsh environment like desert, Nominal Module Operating Temperature(NMOT) 42±2°CW r` Q farm and coastline Temperature Coefficient of Pmax -0.36%/°C Q J W t Rom' ,sso Z W 0 O _I Temperature Coefficient of Voc -0.304%/°C a _ Certifications and standards: c�:,%us /IT Temperature Coefficient of Isc 0.050%/°C 100 < U �, LIL 61730 =soMIMI Q (,/� CD z W Intertek J Sr 1600 1 W I-co O CV Trust Suntech to Deliver Reliable Performance Over Time Special Cell Design Al 1 Q M itoo •World-class manufacturer of crystalline silicon photovoltaic modules The unique cell design Solar Cell Monocrystalline silicon 166 min i • Rigorous quality control meeting the highest international standards: leads to reduced electrodes :o ISO 9001,ISO 14001 and IS017025 MINo.of Cells 120(6 x 20) 7 resistance and smaller a� a •Regular independently checked production process from international current,thus enables higher Dimensions 1755 x 1038 x 35 mm(69.1 x 40.9 x 1.4 inches) ntagem so accredited institute/company fill factor.Meanwhile,it can Weight 20.3 kgs(44.8 lbs.) reduce losses of mismatch Front Glass 3.2 mm(0.13 inches)tempered glass -10oowtne-000efol^_cont.,�a'OWr"t-a00 wiett •Tested for harsh environments(UL 61730)** P • Long-term reliability tests and cell wear,and increase Frame Anodized aluminium alloy Sheet Name •2 x 100%EL inspection ensuring defect-free modules total reflection. PV MODULE Junction Box IP68 rated(3 bypass diodes) Output Cables 4.0 mm2, SPECIFICATION Portrait:(-)300 mm and(+)300 mm in length SHEET or customized length Industry-leading Warranty based on nominal power IP68 Rated Junction Box Sheet Size Connectors MC4 EVO2,Cable 01 S 100% MIN Suntech linear warranty The Suntech IP68 rated ANSI B 92, Standard linear warranty junction box ensures an Dealer information 11 outstanding waterproof 1 1 X 17 ,0 level,supports installations in all orientations and Sheet Number Ill Banreduces stress on the cables. Container 20'GP 40'HC 0 1 12 25 Pieces per pallet 31 31 D S 01 Pallets per container 6 26 iiegam -0.55 0 0 ... Pieces per container 186 806 First year power Annual Product linear Packaging box dimensions 1786x 1130x 1203 mm degradation degradation warranty warranty Packaging box weight 679 kg Intotniatton t:r horn to -ts.and operate rots predua o avatlable in thP nsiahlation 1nst1uction At valu s indicated in this data sheet are s feect to change without poor announcement The specifications may vary slrghdy.All specifications are in accordance With standard EN 50380.Color dffcrerues of the modules fetahvete the figures as welt as discoloration of/in the modules which do not impatr their prop.fon.Aonmig are possfik and do not constitute a deeiMbn from the specification, refer mu Suntech Standard Module lns,allation Manual for details. `Please ides to Suntech Product Nea,coast Installation Manual for detail. .Pleas.refer to Suntech Product Warranty for detail. ©CopSrlylot.e='Sunr .hn--t•.or www..SUnteCh-power.com NUSA pyrighr _ S. mover www.surttech-power.com NUSA s 0 infinity solar Technical Specifications Technical Specifications INFINITY HOME SOLUTIONS Model HM-300N HM-350N HM-400N Model HM-600N HM-700N HM-800N 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 Input Data(DC) Input Data I DQ INFINITY SOLAR.COM Commonly used module poem!(W) 240 to.405+ 280 to 470+ 320 to 540+ Commonly used rnocule power(W) 240 to 405+ 280 to 470+ 320 to 540+ REVISIONS Maximum input iraltage rvi GO Maximum input voltage(V) bO Descripfion Date Rev MPPT voltage range ly) 16-60 MPPT voltage range(V) 16-6U Start-up voltage(V) 22 Start-up voltage(V) 22 Maximum input current(A) 115 11.5 12!, Maximum input current(A) 2 Ai I 1.5 2 x 11.S 2 x 125 Signature with Seal Output Data(AC) Output Data(AC) Peak output power(VA) 300 350 400 Peak output power(VAI 600 700 80u Maximum continuot.n output power NA; 295 349 382 Maximum continuous output power(VA) WU WAS 766 Maximum continuous output currerrt(A) 1.23 1.42 1.45 1.68 1,59 1.84 Maximum continuous outp-rt current(A) 2.46 2.84 2.90 335 3.19 3.68 Project Name& Nominal output voltage/range fo 240/211-264 208/183-228 240/211-264 2081183-228 240/211-264 208/183-228 Nominal,output voltagedrangie(V) -24U/211-26.4 20R,183-228 240/211-2M 7081183-228 240011-764 2013163-22F Address Nominal frequency/range(I-14' G0/55-65 Nominal frequencwrange(Hz) 60/55-55 Power factor djusta >0 default r-0.99 default (able) Power factor(adjustable! Oil lead in.99 g_..0.8 lagging 0.8 leading 0 8 lagging Total harmonic distortion <3% Total harrnono distorton .c3vi LLJ C_) a_ Maximum units per branch' 13 1- 11 9 ^,C E Maximum units per branch' 6 S S 4 :, 4 z 0 C) u•-I 0 co cd), Efficiency Efficiency 0 --I c\I 1,-;.. c.7) LO L1.1 ,I-U 6) ,i..1'-' '-e---C CEC peak efficient). 96.7'95 LEL peak efficiency 96.7% LI w - z z Ill 0 CEC weighted efficiency 96.5% LEC weighteo efficiency 96.5% 2 _ < CD 121 ----< Ct . Nominal MPPT efficiency 99.8% NM-MX?WWI efficiency w8lit > < di L11 CD co o z Nighttime power consurriptionlmW) <50 Nighttime power consumption(wry) •5o LC! co j= 0 CC Ril M < co eL Mechanical Data Mechanical Data -3 ',- Ambient temperature range rn -40 to+65 Ambient temperature rang*f•C) -40 to.55 Dirnensions(W s He 0 mm) 182 s 164 x 29.5 Dimensions PH x H x D mm) 250 x 170 x 28 Weight(kg) 1.98 weight(kg) 3 Enclosure rating OuldOor-NE MA 6(IP67) Enclosure rating OUtd0Or-NEMA 6(11-14,71 Sheet Name MICROINVERTER Cooling Natural convection-hk tans Looting Natural convection-No fans SPECIFICATION Features Features SHEET COMmunic.ation 2.4GHt Proprietary RF(Nordic) Corn municanon 2.46H7 Propnetary Rr(Nord,- Street Size Monitoring 5-Miles Cloud Montronrc 5-Miles Clouc. ANSI B Warranty Up to 25 years Warranty Up to 25 years 11" X 1 7" UL 1741,IEEE 1547,UL 1741 5A1240 Vac),CA Rule 21 r,240 Vac% Compliance LA 1741,IEEE 1547,UL 1741 SA(240 vacl,CA Rule 2 1(.241.1Va0. Sheet Number CSA C22.2 No.107.1-16,FCC Part 15B.".;CC Pan l 15C compliance cSA c 22.2 No.107.i-16,ICC Part 158,tts..van i se. Conforms with NEC-2017 and NEC-2020 Article 690.12 Conforms with NEC-2017 and NEC-2020 Article rz.9G.12 PV Rapid Shutdown PV Rapid Shutdown OS 02 and CEC-2021 Sec 64-218 Rapid Shutdon PV w of Ste77.6 and CEC-2021 Sec 64-2113 Rapid Shutdown of PV Systems *1 Nominal voltage/heti uenty range can vit..;deper'd wry on total requirements. '1 Nominal voh'agetfrequercy range can vary depending on kcal requirements. .2 Refer to local requirement!,for exact r..r :.,,r of - .-:,inverters per branch •2 Refer to local requirements for exact number of microinyerters per branch. *3 Hoyrnile'. '2 ortitoring System,. '3 Hoymiies Monitoring System. 0 202' liorii ies Fuiver tiro-Quip,lit. A'rlii--..t....!.11,111. 0 Technical Specifications infinity solar INFINITY HOME SOLUTIONS Model H M-1200N HM,1500N 6405 E MILL PLAIN VANCOUVER WA 98661 Input Data(DC) PHONE:1-800-818-0598 INFINITY SOLAR.COM Comm used module power CiV, 240 to 405- 300 to 505+ tREVISIODN Maximum input voltage.(V) 6,.) Description ate Rev MPPT voltage range(NII 16-611 Start-up voltage(v) Maximum input current(A) 4 0 11.5 4 x 11.5 Signature with Seal Output Data(AC) Peak output power NA) 126G 120XI 1500 1351) Maxirrwm continuous output power(VA) 1 20L1 1109 1438 1246 Maximum conhnuous output current(A) 5 533 5.99 5.99 Project Name 8, Address Nominal output voltage/range(V) 240/217-264 2(343$!10-22E1 24W-211-264 208/18.3-2213 Nominal frequency/range(117) 60/55-65 :4.).99 default Power factor Ladjustabilel OM leading...OS lagging Total harmonic cliVocoon -s3)73 W 0 a_ ' Z 0 c", liolax rn rtc imJ units per brah .73 : . . ..' LLI 0 „ s) 0 -- C\J N- Effidertcy Lt _/j) Ct-C.peak efficiency 961tik z LU 0 FD7) -',• = (IC weighted efficiency 96.596 < C.) Cl----< Ce . > >• < Lii L.L.1 a (J3 C9 = Nominal tielPki efficiency 99.8% i i= 0 w g41 m Nighttime power consumption(mW) CSU -3 ,-- Mechanical Data Ambient temperature range("L) -40 to.65 Ltimenstans(kv+.,H x 0 MM) .211I1 0 176 x 33 VOok3hr(kg) 3.75 Sheet Name MICROINVERTER Enclosure rating Outdo•ar-NEMA 6(IP671 SPECIFICATION cooling Natural convectkon-No fans SHEET Features Sheet Size Communication 2.461-i7 Propnetary RP(Norcir) ANSI B 11" X 17" Monitonng S4.10es Cloud' Sheet Number Warranty Up to 25 years -I. 1141,JELL 1 54 1r,Lk 1 741 i5i(240 Vat%CA Ruie 11(tAIJ VaCL DS 03 Cori pliar,:e J,.SA U.L2 tic.107 1-lb,t-CC Parr 15B,FCC Part 1St Conforms write\H.-2017 arc!NEC-2020 Article 690.12 PV Rapid Shutdown and LECI-A:21 7.:er(-.4-21s Rape Sh.irdowr of IN ystems '1 POraflal vottagerteouerry range can vary depending on local requirements. -.-ciLefe,-,- oral requirements for exact nu- r-of oocroirwerters,per branch ---o,..-- --7oniroring 5vs".ern. d 202-1 litiy., ,...1•Yrf fiCli,(X111.`AIL 4 jhb letcivrt.1 0 infinity solar ,T, INFINITY HOME SOLUTIONS ti 6405 E MILL PLAIN VANC WA 98661 VER Powering Business Worldwide pe.eaton.com PHON�:U1-8 0 8 8-0598 INFINITY SOLAR.COM REVISIONS Description Date Rev BR style 1-inch loadcenter Signature with Seal BR816L125RP UPC:786676001472 Dimensions: • Height: 13 IN `' Project Name& Addres• Length: 3.56 IN • Width: 11 IN Warranties: • 10 year w U 0_ Specifications: w 0 0-) o • Special Features: Current design w • Type: Main lug _i c m z • Amperage Rating: 125A z = o • Box Size: 7r • Bus Material: Aluminum o o z w w N j= O • Cover: Cover included cc RI m eL • Enclosure: NEMA 3R —) • Enclosure Material: Metallic • Interrupt Rating: 10 kAIC • Main Circuit Breaker: BR • Number Of Circuits: 16 • Number Of Spaces: 8 Sheet Name • Number Of Wires: Three-wire COMBINER PANEL • Phase: Single-phase CERTIFICATION • Voltage Rating: 120/240V Sheet Size • Wire Size: #14-1 AWG Cu/AI ANSI B Supporting documents: 11" X 17" • Eatons Volume 1-Residential and Light Sheet Number Commercial • Cutler-Hammer Type CH and BR Loadcenters- DS 04 Instructions • Type BR Arc Fault Circuit Breakers and Loadcenters • Eaton Specification Sheet- BR816L125RP 3 Switching Devices 1 1 Switching Devices infinity ,rOICr Safety'Switches • INFINITY HOME SPLUTIONS SafetySwitches VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM Product Overview 1 1 Product Description Standards and Certifications • Used to open or close • J_ 5` 3 REVISIONS Product Selection Guide a circuit • UL 50 Description Date Rev • Non-fusible safety • F4EMAKS-1 Safety Switch switches provide a means .- to manually connect or disconnect the load from U .9 t R i the source L 1 • • Fusible safety switches Signature with Seal a ' r - `' prow de a means to ` 1 a a'x , manually open and close a circuit and overcurrent . protection by means of t '^ ,, .4'"' ' °'' installed fuses .... *, • Also commonly referred to as a disconnect switch Description Gemini-Duty Nuuer-Day Sec-Poke Mc lb Discur Duna-ltow twined Rotul Patton or disconnect Project Name& V, t eire,Frrtnr Inge rawer nr.3tna1l Stick 7., a ., htstriunSIEtP3 ii,ilt tn.in Gar VT" a Available from 30 to 120OA Address 243Varh0rsagemormet C+"`C.l,DCta/wooerWed MeV& losniaturgtad use r FtlablE Mug sartrl car-:; .- ... Cash* — NW c147,- Fuit L LI Amatora'n lustre at{' 32 tC' 30-2011 30 12 : Z 0 cra 0 trtr S ine 30403 23 t20e st-100 30 1.7a; t O N ti 4Ukroet x pos N tullee 1,281123 . '._-*6 28nt3 LJJ w rn r- Q — n, CO Et "1- Z 2 a1D a Nm-t3 '3rW 3 ?3,4 flrtl6 t 3r9#s: 33016 z = 0 o J Q 00Et -< r PIEW are 0 Cad z w !Asti: NIA3n —D Noe R6fuE l'S •'h`-` NL4A 17 fiat* %1tNrhat >up MID':N:.'.' 9n'C WOO NErA 4 to rr 1 FMOP Yan 4 Kr,' tea-i lstio "VI Op.. ' Sheet Name NFU&41X steles stool AC DISCONNECT Fat* va =:.upta:xr. ve; UL CERTIFICATION `yin t>ad€ Yes tp arc 1.:,, -. > up rc VOA .. NFu 4Rrtrntr!o13 : Sheet Size wstale f s Lott X:' ANSI B TRWFusitItr'? Y,z.sup is Itt;.! 11" X 17 Faiontsi tte vas uptc la::'... Sheet Number IMPS Q: Sue spotlit raaI6g mantel pie MY Fine ilIFS netalls.trclrss0 totary mutes steno- ..ire_m1c NEMe.Type'a enstum res;30.1k k tan to teld maattce to reel N[MA a1 ratrptool regniements'Zeta lto i L Won Ian s:new mien-ma D S 05 sx- Mass J ttso oitz mac. Volume 2—Commercial DFstnitiu ion ;4 s s iV_9-4pri176]6 were, stun. V2•11-2 V2-T1.4 Volume 2—CommerclaI Dlstributton CA481086O3E—Apn17Old wens.aatancar • Switching Devices 1 0 Switche5 1 * 1 infinity solar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 Cross-Reference 1 INFINITY SOLAR.COM General-Duty General-Duty,continued REVISIONS Ampere Catalog Number hopere Catalog Number Description Date Rev Raing Eaton GeneralMark Siemens Square C Rating Ellen General Electric Siemens Spire D PIUg Rise.Single-Pole.two-Wire,120 vac„PkMA 1 Fusible,Two-Pole,Three-Wre,240 Vac,NEW 3R 11 DP1IINGB TIT 130 .'1°`r, V!Ili ii OG221NRB 163771'? 7?71011 ;;2INH3: Plug Rise.Two-Pole,Three-MR.240 Vac,NENIA 1 DG222NR3 TGTlY G7-:22Wi 7222Mfl :II DP211NCE 111233 1I711N Jr IN; DC22740E1 163773'1 Cf7llifi 072 N18i Signature with Seal P051b1e,TWo-Pole.Three-Wire,240 Vac,NEMA 1 211 0G224NRK 1G3224F GF2241W D724N113 1 D6121NGB 1G2t21 13771N ]7lt. 40: 0C2294RK TG372'1 GP77'.049 O71'.,NH CII 067;£2I1GB 1GQ7f7 EF712n1 ':$'N. C:t_ DGI26NRK TG377Li :nr•'4i 0770111 100 4621714GB 1G3323 SP-227%, :230i Fus te,Three-Pole,Three-WIrN,240 Vac.NEMA 2R 200 D6224NCK 10724 Eli'!'. :'"P 711 D6721NRB T64371F .''Yi niNH:i 400 OG2291GS 1l E27N Gf:'_ . GI OGU MR8 TGl3T2R GF)2 1 0373Nn1! Project Name& GOO 0G226NCK TC3721; 1727t:1 3i:1,1. 1NJ OC123NRB TG4.T23R 6F3974, I7313NRI} Address nibble,Three-Pole.Three-es.240 vac,NUM t 293 0632411PRK TG137". [m74Pf 03I4N11Ii 3E1 DG321NGB 164371 T3321N DIZIN 433 DG133F111( TG'::_- CF37.941 6376NH IT 13G722NGB 164327 1277744 032211 603 06725FRK ''1337CFF GF3704R 0326NH DGITINGB 11,4r3 "'i73Y WIN Fusible,Three-Pole,Four-WS'e,240 Vac,II MA 2R W • DGv4NcK 164324 Cht 3324N 71 0C121NR5 IG4321R r2171NR O'371NHI U d OG725FGK 16232`: ::2J4 D375N DC122NRB TGIJ[lH G 221.0 R327N11€! o 0 rn . DG726FGK 1 �', GT32411 OMEN DGU2NRO ''.141ril GT3TJNP 0323NRI 0 O N SD) Fusible,Three-Pole.Four-Wire,240 Vat•.ra=MA 1 2113 OG724NRK 1G4324R Gr324NR 0314N115 w W 0) ti Q DGI2INGB 1143 P 3 I ' _71N 0 i' 403 DG325NRK TG37lJ3 GT37`.AR t231r.Nfi J ^Z W O co ' DC/URGE IG43^ i_?7N 0 11 603 OG7lWRK T633765 CF33UIFi T171GNH z U 0 Q DG121NG8 11,432 I73T3N 03231 Non-Fusble,TWo-Pole,Two-Wire,240 Vac,NEMA 2R < Q W W DGIZ4NBK I,.43N, 11324N 4324t 37 OG221URB IGN3:7' IN 21F 0 Cn C7 Z DG725NCK IG432'', '-I':xJ4 D32 N 06222URB TGNS127- Gt4T377R i -, W N ~ 0 DG125NGK Ia3;i. _'•7GN D8261,1 D6227URB TGN33721 GV3Yli 602023AIRE < � IL mon-FU61DIe,TWO-Pole,TWD-Wre,240 Vac,NEMA 1 DG324URK 16N337411 ,';7VFl (1tfl24F0 30 OG221UGS 1E 1321 WA NM NonfusIDle,Tome-Pole.Three-Wee,240 Vac,NEMA3R CO DGMUGB IGN3T27 N,'A EiCaltN.ETS :0 0G321URB `:d.'337111 GYF37111 01t371I) 171' DG22IUGB I6t42323 NIA OIYrY.ON'• ''C DG1122UR13 7.1N3227A GlE322# 01.92293 00124UGK 1El3324 IVA I). . 00 DGIZIUR8 :INLWSI GNF373R UU323115 DG12Sl1GK 1E043326 WA 011iZ. 200 DCI24URK 1GNx124R I3/32419 01/324IEt Sheet Name DG126UGK 104337G N,n OWN 400 DGMURK WA WA WA AC DISCONNECT Non-Fusible,Three-Pole,Tree-wre.240 Vas,MIA 1 R OGI25URK WA WA '7, UL CERTIFICATION DGIZ1UGB iEN3321 Ca'1::-.' ._ . Mies 0G722UGB Ir143322 Vir722 Ii <. Sepuale recta Cr mgu1ed Sheet Size DG327UGB 1 cr43373 74T373 1'r.. AIN'ayslerIN Re roar cT roes aro 1Nre3 re tec-s'."c,atazg rxirreers nth'appeal r rnrR le ANSI B Dc1I4iSK T:r43324 GNT374 D6125UGK 1E Ar225 ENEZT, 11" X 17" DC326UGK lE1J212C Sheet Number DS 06 'v'olunte2—ConmerclaiDKlrlbittion CA08100003E—Apnl701G rpm axon.Lyn V2-T1-6 . 0 /� infinity solar RSTCEnterprises, 1#M I c. op ill II ilk INFINITY HOME SOLUTIONS '"�}} J� Heimstead �+} Road 6405 E MILL PLAIN 2214 1 1eims�Lfead 1 \Vad VAN05EMIL PLAIN 1 Eau Claire, Y Y I 54703 + L A � E K PHONE 1-800-818-0598 INFINITY SOLAR.COM 715-830-9997 / FLASHED !'V ROOF-MOUNT REVISIONS lappioCOMBINER/ENCLOSURES Description Date Rev Outdoor Photovoltaic Enclosures 0799 Series CompositienlCedar Roof System Signature with Seal ETL listed and labeled tI Report##3171411 PRT 002 Revised May, 2018 '' ;.t • UL50 Type3R. 11 Edition Electrical equipment enclosures � � Project Name& • CSA C22.2 No. 290 Nema Type 3R Address • Conforms to UL 1741 Standard 0799 Series Includes: °`r� 0799-2 Wire size -14 '""� '�59-�' �` z o 0 0799-5 Wire size 14-6 a o co o 0799-D Wire size 14-8 "' w ti a Models available in Grey,Black;or Stainless Steel z w p .J > < W W Basic Specifications u CC) p o < � EL Material options: • Powder coated. 18 gauge galvanized steel a.a. (1,100 hours salt spray) • Stainless steel Process-Seamless draw(stamped) Sheet Name Flashing - 15.25' x 17.25" JUNCTION BOX UL Height-3" CERTIFICATION Cavity-255 Cubic inches Sheet Size Base Plate. • .n ' ANSI B • Fastened to base wing toggle fastening system - 11" X 17" • 5 roof deck knockouts �. Sheet Number • Knockout sizes. (3) _5x,(1) .75'and (1) 1" • 8',35mm slotted din rail : � �� DS 07 • Ground Block Passth h and combiner kits are available for either .� _• : '` AC or DC applications. Cis-Linked Polyethylene Insulated 0 2kV Rated FM 18-750 MCM•2000 Vats•-40°C to 90°C Wet and Dry infinity solo INFINITY HOME SOLUTIONS 6405 E MILL PLAIN Description VANCOUVER WA 98661 Ew PHONE:1-800-818-0598 ADC's Solarknk brand Photovoltaic cable has a chemical y INFINITY SOLAR.COM 1 cross-linked polyethylene insulation. I Bare Ca perApplications0, : , REVISIONS pp Description Date Rev 4 Appropriate for use in solar power applicatioins that require I 2,000 volt rating. For use in grounded interconnection and 'Iliii0 mil unwounded unwounded Photovoltaic power systems. Construction /* Con tors: Stranded bare copper conductor per ASTM B-3.B-8_ Signature with Seal 1t X LP Insulation Available in 7 or 19 stranded versions as well as tinned copper. Insulation: Chemically Cross-linked polyethylene 0 N e So1arin k Colors; Black,Green,White,Red. Print on one side with a : contrast ng nk. An extruded stripe and other colors are avail- Project Name& abke upon request Address Industry Listings 8 Standards 0 t t.Listed as Photovcataic Gable per Standard Subject 4703 and 44 Cable Identification -4 °C1913°C Wet and Dry Rated p 'ADVANCED DIGITAL CABLE INC. )0(AWG{UL) Gasoline and Oil Re istant II w rim, PV WIRE OR RHW-2 2000V OR USE-2 600V 80°C Rolle Compliant l RAN r 'JET OR DRY(-40C)SR GRII DIRECT BURIAL RoHS Sun fight Resistant 4.e., w 00 rn 0 E324841' YAW-1 Flame Rating Optional LISTED 0 J N o X W w rn ~ Q tY J d- Z illInsulation Thiele- Approximate Z = 0 O Nominal ts.D. Z �? Part Number AWG Strand ness Net Weight Z C� 0 Q ' - (mil (inch} !ban NI' > < w w /I� 3'82NPV 18 75 .196 1£ 0 co I O 3'62twPw' if 205 22 Q m a 3142NPV 1..1 7 7E 22" 28 31Z2NPV 12 7 76 .242 38 3102NPV 1 C 7 .264 61 3082NPV 6 7 86 .31. 78 30 2NPV 6 7 85 .351 112 3042NPV 4 7 85 .399 166 Sheet Name t !rka'NPV - 7 85 ..t27 203 WIRING 3022NPV 7 86 .�59 a4g SPECIFICATION E 3012NPV 19 105 .539 323 O102NPV 1lV lii 105 .572 390 Sheet Size 30202NPV 2110 10 105 .616 480 3030ZNPV 3/0 19 105 .667 593 ANSI B 30402NPV 4/0 19 105 722 737 11" X 17" 3C2502NPV 250 MCM 37 120 798 879 _ Sheet Number r. 30300 ( 300 MCM 37 120 6 10-c 303602NPV 350 MCM 37 ,20 9011192D S 08 304002NPV d0o MCM 37 120 .96 1s66 3OSOO2NP'V 500 MGM 37 120 1 029 672 306002NPV 600 MCM 61 1366• 2y i 1 N 307502NPV 750 MCM 61 136 .236 2612 Tne irdormatton mistral on the spu 1I:sit1zr I;tteut+d Iv to and as a.guide In pmuird setecborr and Is bellered to be reliatle. ADC has male every etrnd to dare the dab AVM exwe Is=unite a the line d'ritiltable.11 epatialloa b»tiled to+age atw9rne without ni*tce REVG618 Li" PHONE: (800) 343 2579 • FAX: (828) 389 3922 WWW.AOCABL.E.COM , E.) ICESTech Brief infinity Mar INFINITY HOME SOLUTIONS f# ►. IRONRIDGE XR Rail Family XR Rail Family VANCOUVER PLAIN 1 PHONE:1-800-818-0598 INFINITY SOLAR.COM The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location,there is an XR Rail to match. REVISIONS Solar Is Not Always Sunny `�.. / Description Date Rev Over their lifetime, solar panels experience countless Mit extreme weather events. Not just the worst storms in years, , + -T—lle ii but the worst storms in 40 years. High winds capable of { ,' - 1 ripping panels from a roof, and snowfalls weighing r' *7. `�`y Signature with Seal enough to buckle a panel frame. • + XR Rails are the structural backbone preventing "--- - ,- ;* ,,, , ; t , -...............................alli .....„........................imlll --................................40- X - .� these results.They resist uplift, protect * + T. XRiO XR100 XR1000 } `I i against bucklingand safelyand g efficiently 4.f T t XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the buildingstructure. 1 rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle Project Name& It l� . no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or Address Their superior spanning capability p P 9 P y + remaining light and economical. maximizing spans up to 8 feet. more for commercial applications. requires fewer roof attachments, • reducing the number of roof , - • 6'spanning capability • 8'spanning capability • 12'spanning capability penetrations and the amount • Moderate load capability • Heavy load capability • Extreme load capability • Clear anodized finish • Clear&black anodized finish • Clear anodized finish of installation time. . . - Internal splices available • Internal splices available • Internal splices available -, - U CD a^ Rail Selection W o m o / The followingtable was prepared in compliance with applicable engineering codes and standards. Values are w w 6 Q P PP 9 9 ct J � ^Z t based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean z = O o i Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. z U o :2' Q Q ui w Load Rail Span ow u, cp o Snow(PSF) Wind(MPH) lizgo 6' 8 < co 0- Force-Stabilizing Curve 100 , Sloped roofs generate both vertical and lateral r NOne _ 120 to bend and twist.The curved shape of XR Rails a XR1000 . isspecially designed to increase strength in both 140 I XR10 forces on mountingrails which can cause them spec a yg directions while resisting the twisting.This unique : Sheet Name feature ensures greater security during extreme 160 1. . „ weather and a longer system lifetime. 100iii4 ,;t•" � RACKING-DATA ,, ' '. s SHEET 120 10-20Alfat : i Sheet Size - ‘i - l' 140 AN SI SI B m... -__,_._- 1 17" 100 30 Sheet Number 160 A . :. '- ;M - 31:11 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials l 100 € "-Y DS 09 L XR Rails are IronRidge offers All XR Rails are made of marine-grade l 40 ' " I ` , compatible with a range of tilt leg aluminum alloy.then protected with an 160 E ''�, y , 21 C.) FlashFoot and r t options for slat anodized finish.Anodizing prevents surface R other pitched roof 1 1 roof mounting and structural corrosion,while also providing 50 70 160 attachments. applications~ a more attractive appearance. 1111111°' `-."--- 80-90 160 0 2014 IronRidge.Inc.Ali rights reserved.Visit wwwironridge.com or craft 1-600-227-9523 for more information.Version 1.11 / I • L ) infinity suNmort,231, y� Key Features of NanoMount TM S(JNiS�: INFINITY HOME SOLUTIONS -ry.. ( i -. -xha. :. 6405 E VANCOUVMILL R WAPLAIN 98 r4 We've Got Yaur Rock! PHONE 1-800-818-0598 „ . 661 INFINITYSOLAR.COM , k 4 - E: ,_ 5 levels of protection against REVISIONS tane�k Description Date Rev i water penetration soLARis �nf : _�- Aesthetically pleasing unibody aluminum cast construction it fc,- , :.wie Signature with Seal FASTEST 360-degree positioning, •`` a �� g p 9 serrated surface on both ATTACHMENTA ,..,,,,. , , sides for rail mounting Project Name& NanoMountT`" Address Versatile mounting option xy includes direct-to-decking . for fast installation '*� w ,;, / z o o ` ca Nano Rafter o ti Mount w w : ti ¢ 0 Z w ° o Li 0 � Q U ix, Integrated Ultra Soft Weather a c z w Resistant silicone gasket ' wW N ~ 0 The NanoMount Advantage '` Damaging roof shingles used g .-�-' , -, to be one of a solar installers' Alignment markers J The fastest roof attachment in enable easy installation ft' 8 worst challenges. solar N., -,/ Versatile mounting options Sheet Name Now, the easy, affordable including direct-to-decking MOUNTING- solution is NanoMountTM, Technical Data DATA SHEET SunModo's newest solar ./ Eliminates the need to lift Sheet Size shingles and prevents damage to Application Composite shingle and rolled asphalt mounting innovation. ANSI B shingle Material High grade aluminum, 304 stainless steel hardware 11" X 17" The mount consists of only two ,/ High-Velocity Hurricane Zone Finish Black powder coating Sheet Number components and eliminates Approved - Passed TAS 100 (a) Roof Attachment Rafter and decking DS 10 the need for lifting shingle, Wind-Driven Rain Test Structural integrity IBC and IRC Compliant thus significantly cutting down ,( All materials are compatible with Warranty 25 years the installation time. roof shingles SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com ,.., infinity,, %I& IRONRIDGE UFO Family of Components System Diagram INFINITY HOME SOLUTIONS 9 6405E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM Simplified Grounding for Every Application - - - 0 0- _ _ _ _ -0 0 • C REVISIONS Lott�s. Description Date Rev The UFO family of components eliminates the need for , - separate grounding hardware by bonding solar modules directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. 1 1) _ _ _ _ _ _ 0 O_ _ _ — _ —O 0 = Signature with Seal UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more reliable installations. alb • E Project Name& Address , „-- , \ Stopper Sleeve Universal Fastening Object(UFO) i The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO,converting it into Rails.It comes assembled and lubricated,and _ _ _ _ _ _ _ W can fit a wide range of module heights. U ilk tiii a bonded end clamp. 0 O_ _ _ _ _ _0 0 z O o rn " W W p~j Q w w ,/�_ 0 UFO ( Stopper Sleeve • Grounding Lug m BOSS'" Splice — Ground Wire z E — > Q� ww - �/ �^� P 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for Q l/ ,' - `. grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the M _ ' ! / same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. :. • ,,,,,, -;„:,.4,, y f ~' ,� t"�i UL Certification Cross-System Compatibility r The IronRidge Flush Mount, Feature Flush Mount Tilt Mount Ground Mount Sheet Name Tilt Mount, and Ground Mount RACKING- ,M / XR Rails V V XR100&XR1000 GROUNDING BOSS Splice lei- Systems have been listed to UL — ---,__.. .`` ',., ; UFO/Stopper .i Bonded Structural Splice - �> ®,� '�,-,,; 2703 by Intertek Group plc. pP w connects rails with built-in Sheet Size bonding teeth.No tools or BOSST"' Splice d d N/A hardware needed. / SI UL 2703 is the standard for — ANSI B evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices `" 11 X 17 Microinverters t Com atible with most MLPE manufacturers. will maintain strong electrical and &Power p Sheet Number j Grounding Lug mechanical Connections over Refer to system installation manual. .w '� A single Grounding Lug Bonded Attachments Optimizers 4llr an extended period of time in — - ps �__ , y� connects an entire row The bonding bolt attaches Fire Ratin Class A Class A NIA of PV modules to the and bonds the L-foot to the extreme outdoor environments. g grounding conductor. rail.It is installed with the raomi ■rN►' same socket as the rest of the Modules Tested or Evaluated with over 400 Framed Modules ' system. 0 Go to Iron# UFO Refer to installation manuals for a detailed list. ��, 02021 tronflidge,Inc.All rights reserved.Visit www.ir-patents.cwm for patent information V ' , o B --_— _ infinity s,::(1,- • 28375 Industrial Blvd. 28375 Industrial Blvd. INFINITY HOME SOLUTIONS Hayward,CA 94545 Hayward,CA 94545 64VAN 05 E MILL ER WA 98661 IN /,I, IRON RIDGE 1-800-ge.co23 /.t IRON RIDGE 1-800-227-9523 PHONE:1-800-818-0598 IronRidge.com IronRidge.com INFINITY SOLAR.COM REVISIONS Attn:Corey Geiger,COO, IronRidge Inc. Description Date Rev The parameters and adjustments allowed in the span tables are defined as the following: Date:May 18`",2020 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-10 Chart 1.5-1. Re: Structural Certification and Span Tables for IronRidge Flush Mount System 2. The wind speed selection shall conform to ASCE 7-10 Fig.26.5-1A(Risk Category II wind)and any state&local This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System.The contents county/city amendments to the IBC. No special wind topographic features are included in the span tables and the Signature with Seal of the letter shall be read in its entirety before being applied to any project design.The Flush Mount System is a topographic coefficient(Kzt)is taken as 1.0. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and 3. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig.7-1 and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof attachment with applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to format of a flat roof snow load,it shall first be converted to a ground snow following the local building the underlying roof structure.Assembly details of a typical Flush Mount installation and its core components are shown in code/amendment before the application of the attached span tables.No special snow conditions are considered Project Name& including unbalanced,drifting,sliding,retention,or ponding snow.The span tables do not include buildings which Address Exhibit EX-0015. are intentionally kept below freezing,kept just above freezing,or unheated. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below,for the load conditions and configurations tabulated in the attached span tables. 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: 1) For ground snow no greater than 42psf:Ss<2.0g for Site Class A,B,C,or D. Lu • ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) U o_ 2) For ground snow greater than 65psf:Ss s 1.0g for Site Class A,B,C,or D. Z 0 cp • 2015 International Building Code(IBC-2015) w 0 m o 3) For ground snow between 42 and 65psf:Ss<_1.5g for Site Class A,B,C,or D. 0 J N r` • 2015 Aluminum Design Manual(ADM-2015) N W w rn ti Q 5. Roof zone size and definition conforms to ASCE 7-10 Fig. 30.4-2A to 30.4-2C. lY u �- z The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the z w 0 o respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones 1,2&3,and roof 6. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a Q U Cl. Q slopes from 8°to 45°.The span tables are applicable provided that the following conditions are met: minimum of three spans. > ¢ li.i w o co 00 z w co O 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment 7. The maximum cantilever length measured from the rail end to the nearest attachment point shall not exceed 40% < co fastener) of the allowable span provided for the respective load&configuration condition from the span tables. 2. The underlying roof pitch,measured between roof surface and horizontal plane,is 45°or less. 8. An array to roof clearance of 2"minimum must be provided. 3. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from 9. No rail splices are allowed in the cantilever,outer 2/3 of end spans,or middle 1/3 of interior spans. grade,does not exceed 30 feet. 10. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded.If Sheet Name 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module such conditions are encountered contact supportaironridge.com. RACKING- width shall not exceed 42". 11. When a roof attachment listed in IronRidge's Flush Mount installation manual is considered,the span values CERTIFICATION 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount provided in this letter can be adjusted using IronRidge's online Design Assistant by checking the capacity of the installation manual and other applicable standards for general roof construction practice. selected roof attachment against the reaction forces provided in Design Assistant. Sheet Size ANSI B 11" X 17" Sheet Number DS 12 ©2020 IronRidge,Inc. TX Flush Mount System Certification Letter-1 ©2020 IronRidge,Inc. TX Flush Mount System Certification Letter-2 I