Plans (2) JOSE & KRISTIN SOLARES DECEIVE®
NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM
SEP 2 9 2022
DC SYSTEM SIZE (6.29 KW) UITYOGTIGARD
DM
BUILDING DIVISION
SION
Signature with Seal
R SITE MAP (N.T.S)
SYSTEM DETAILS � � s VALIDITY OF PERMIT I
THE ISSUANCE OF A PERMIT J �NEW GRID-INTERACTIVE PHOTOVOLTAIC `" A I`
DESCRIPTION
SYSTEM WITH NO BATTERY STORAGE I BASED ON CONSTRUCTION #
DC RATING OF SYSTEM SYSTEM SIZE s.zs Kw DC STC DOCUMENTS AND OTHER I ",T'. ADD:19450 SW MOHAVE CT.,
DATA SHALL NOT PREVENT ` ruACONT,CT 503-95-19 USA.
AC RATING OF SYSTEM 6 KW
THE CODE OFFICIAL FROM _ CONTACT:503-395-1943
REQUIRING THE CORRECTION
AC OUTPUT CURRENT 25 A OF ERRORS. ORSC 105.4 r )
NO.OF MODULES (17)SILFAB PRIME SIL-370 HC MODULES V
W O
NO.OF INVERTERS (1)SOLAREDGE SE6000H-US HD WAVE bfr
cC
INVERTER ,� -- - 49'-10'r -—-- \ �-\ a _
".' S Q
NO.OF OPTIMIZERS (17)P401 SOLAREDGE POWER OPTIMIZER 4 . „ *. x ._ .-. O
POINT OF CONNECTION BACKFEED BREAKER IN THE MSP l Approved plans Z
(1)BRANCH OF 9 MODULES N e''1a1t be On job S .t.. :„". . Z Y
ARRAY STRINGING ,,....,,.....,„.�:,, ". LL:..
(1)BRANCH OF 8 MODULES I N I F-1
I— _IN
VICINITY MAP 'I) 0 C
SITE DETAILS r% O II
�12"FIRE SETBACK �( z Q
ARRAY 2 w
ASHRAE EXTREME LOW -8°C OS)SILFAB 370 HC MODULES ° ARRAY 1 W W ASHRAE 2%HIGH 32°C 05)P-401 POWER OPTIMIZERS 12)SILFAB 370 HC MODULES ^
GROUND SNOW LOAD 20 PSF TILT:27° 12)P-401 POWER OPTIMIZERS ( / CV
AZIMUTH: 181° TILT: 27° O 00
rn
WIND SPEED 96MPH(ASCE 7-16) AZIMUTH: 181°
in
RISK CATEGORY II 01 l .. ,.
' 0 324E SW f Ik.n Tigard.
WIND EXPOSURE CATEGORY B OR 97224 United sexes
111
0° °
(E)MAIN SERVICE PANEL l ��
(INSIDE HOUSE) , - a
GOVERNING CODES (E)UTILITY METER b \
(OUTSIDE HOUSE) cn
1 Z z
(N)AC DISCONNECT AND ��° tt I l 0 0
INTERNATIONAL RESIDENTIAL CODE (IRC)2018 RAPID SHUTDOWN DEVICE °/t` - _� a
INTERNATIONAL BUILDING CODE(IBC)2018 I TSRF:92% cC v
(N)SOLAREDGE SE6000H-US HD WAVE 4�_g�� cC rn
INTERNATIONAL FIRE PREVENTION CODE(IFPC)2018 j INVERTER TSRF:9159 L �x
I T
NATIONAL ELECTRIC CODE,NEC 2020 CODE BOOK,NFPA 70 N
DRIVEWAY l OFF■CE COPY WIND FLOW MAP ci
w
SHEET INDEX
SHEET NO. SHEET NAME \ A 49'-100 '/ J,, CITY OF TIGAIZ]D
A-00 SITE MAP&VICINITY MAP SW NOKIOLh LN
' �I I I \ PERMIT DEVELOPER
REVIEWED�'O CODE COMPLIANCE �"
S-01 ARRAY LAYOUT DATE 09/28/2022
S-02 STRUCTURAL ATTACHMENT DETAIL Approved: I ] " "
E-01 ELECTRICAL LINE DIAGRAM
OTC: DESIGNER OPT
E-02 WIRING CALCULATIONS '"" REVIEWER
Permit#: * NS.7-4 22-- D � (-e7 p
DS-01 MODULE DATASHEET LIABILITY I SHEET NAME
DS-02 OPTIMIZER DATASHEET The City of Tigard and its Address: 82t{�j E v.( f\O{'rvlk- (_,yip SITE MAP &
DS-03 INVERTER DATASHEET employees shall not be Suite ##: / 7/
4 VICINITY MAP
DS-04 ATTACHMENT DATASHEET responsible for discrepancies By: - Date: I ZLZ_
DS-05 RACKING DATASHEET Which may appear herein. ,ane',.. SHEET NUMBER
' 4r, rd 1 A-00
ROOF DESCRIPTION:
(ROOF #1)
MODULES-17
ROOF TILT-27°
ROOF AZIMUTH-181°
TRUSSES SIZE-2"X4"@ 24"O.C. Signature with Seal
,# t;
ADD:19450 SW MOHAVE CT.,
SOLAR MODULE TUALATIN,OREGON 97062,USA.
CONTACT:503-395-1943
12" FIRE SETBACK
L
301_7 W
�� o
, \i,
♦ i� +i - a a --0-----.� . — a-- • --4i-- �Y♦ z
N
LL NI
ts-
N 4,- '- 0- 0.- s'"- 10- \ 1---1 IX a)
\\>/ 1
zoO
LLI
\o o
O °°
IV \ ---1,---—--•---'----40-----'.---.
♦......1 • . ---- a--♦ , Q
� lu
I
V �i o
rl
co
NI -0- -0- -0 0 o
1-1 Lf)/ > x J W U
Ix W
f -• o
6 _
♦ -0 LEGENDS W
1 -FIRE SETBACK c
I
-VENT,ATTIC FAN PERMIT DEVELOPER
31 '-7" __ 10,
(ROOF OBSTRUCTION)
• -PV ROOF ATTACHMENT DATE oszarzozz
G -COUPLING DESIGNER OPT
-RAFTERS/TRUSSES REVIEWER
ROOF #1
— -RAILS SHEET NAME
I -WIND ZONE I ARRAY
LAYOUT
-WIND ZONE II
SHEET NUMBER
-WIND ZONE III S-01
�7
/V 7 22.-00367
i
CONDUIT SCHEDULE ARRAY DETAILS NOTE:
1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE
SR.NO. DESCRIPTION CONDUIT SIZE DC SYSTEM SIZE 6.29 KW REQUIREMENTS OF THE NEC 2020,NFPA 70 INCLUDING MAXIMUM
NUMBER OF MODULE STRINGS,MAXIMUM NUMBER OF MODULES PER
AC SYSTEM SIZE 6 KW STRING,MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL
AO PV WIRE(FREE AIR),(1)#6 AWG THWN-2(G) FREE AIR
NUMBER,INVERTER MANUFACTURER AND MODEL NUMBER,AS
TOTAL NO.OF MODULES 17 APPLICABLE.
O (2)#10 AWG THWN-2(+),(2)#10 AWG THWN-2(-),(1)#10 AWG THWN-2(G) IN 3/4"CONDUIT RUN NO.OF MODULE PER STRING 1 @9,148 2.PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER Signature with Seal
SPACE IS INADEQUATE.
O (3)#8 AWG THWN-2(L1,L2,N),(1)#10AWG THWN-2(G) IN 3/4"CONDUIT RUN NO.OF STRING 2
.EN P1DGE
s z �0
ADD:19450 SW MOHAVE CT.,
TUALATIN,OREGON 97062,USA.
CONTACT:503395-1943
(17)SILFAB PRIME SIL-370 HC SOLAR MODULES WITH
(17)P401 SOLAREDGE POWER OPTIMIZER
LLI
F.
SOLAREDGE SINGLE PHASE HD WAVE INVERTER ce CD
ci
cc
6000W,99%CEC 240 VAC,25A
WITH BUILT IN DC DISCONNECT EQUIPPED WITH
!lw1l PON 11P! RAPID SHUTDOWN Z <
MUNI YilMYi J
tiil:i rtaau INTERGONNEGTION D
Gi IL; Efi3G Fy Y
l a'#c' rwm T^ 120%RULE-NEC 705.12(D)(2)(3)(b) J
W E P rlIVeR H" O N
UTILITY FEED+SOLAR BACKFEED ►�—t LL N-
e�ae� r=��r 200A+40A=240A 0
!mow PRIOR if Z 0
N MI rilldW /110 BUSS RATING x 120%
&LA. 4tiJi,i
[113G Las3E E 225A x 120%=270A 0�
wwir' rw rt - TO UTILITY GRID (A
LU in
L1 (1:2)� O N
n CO
ALSO SERVES AS RAPID (OUTSIDE HOUSE)
i (E)UTIUTY ME
SHUTDOWN DEVICE.TO BE �, 225A RATED,2 0V
wry, 1 r:z.r.`" ® ®Q 5 T LOCATED WITHIN 10'OF
A!!ew :lws 2 UTILITY METER C UU
iIMii YtEMYE I I L L2 ,. a0
lI3r Gi33G I I
!!� �lrlRl! _LrjL1 •��i L1 Lt L2
01
n a
^ (INSIDE HOUSE) N a
— _® ---� -_. (E)MAIN SERVICE PANEL
200A E- -225A RATED,240V CC 2
L__ ____ __ __-I o
0 1.3 u (E)MAIN BREAKER
O (N}AC DISCONNECT 7�C 200At2P,240V Z
240V.&DAMP,UNFUSED w
(1)STRING OF 9 MODULES n NEMA 3R,UL LISTED L7 L,
(1)STRING OF 8 MODULES I �� ^�� >
40A w
re
13 TT • T u
1
ancEE¢ - PERMIT DEVELOPER
— G BREAKER
L_J--C — iIG� DATE 09/28/2022
10001010(1
r DESIGNER OPT
, \.:J GEC#4 THWN TO GROUND RODS OR
EXISTING STRUCTURE UFER
— REVIEWER
L _ --- ----@__ J SHEET NAME
ELECTRICAL
(N)JUNCTION BOX
LINE DIAGRAM
600V,NEMA3R
UL LISTED
OPTIONAL FIELD DETERMINED
SHEET NUMBER
E-01
ELECTRICAL NOTES
ELECTRICAL CALCULATIONS: 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND
LABELED FOR ITS APPLICATION.
2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90
1. PV OVER CURRENT PROTECTION ...NEC 690.9(B) DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR
= TOTAL INVERTER 0/P CURRENT x 1.25 75 DEGREE C. Signature w
3.CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.14with Seal
4.WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS
= (25)x 1.25 =31.25A SELECTED OCPD =40A SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS
POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. GREEN PIDGE
2. BEFORE INVERTER: 5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING
ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.
AMBIENT TEMPERATURE=32°C 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. ADD:19450SW MOHAVE CT.,
CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF NEC 310.15(B)(3)(c) CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, TUALATIN,OREGON 97062,USA
CONTACT:503-395-1943
TEMPERATURE DERATE FACTOR-(0.96) NEC 310.15(B)(2)(a) SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE
GROUPING FACTOR-(0.8) NEC 310.15(B)(3)(a) CODES AND STANDARDS.
7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS
CONDUCTOR AMPACITY ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM U)
= (OPTIMIZER 0/P CURRENT)x 1.56/A.T.F/G.F ...NEC 690.8(B) ACCORDINGLY. LU
= [15 x 1.56]/0.96/0.8 8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDCe
= 30.47 A SELECTED CONDUCTOR-#10 THWN-2 ...NEC 310.15(B)(16) AND READILY VISIBLE. Cal
9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE Q
3.AFTER INVERTER: FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP
MANUFACTURER'S INSTRUCTION. Z j
TEMPERATURE DERATE FACTOR-0.96 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER Z
G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. �--I _1GROUPING FACTOR-1 4.
11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE. V) _O N
CONDUCTOR AMPACITY 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL . rn
rx
= (TOTAL INV 0/P CURRENT)x 1.25/0.96/ 1 ...NEC 690.8(B) PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE OZ O
[(25 x 1.25]/0.96/ 1] ENTRANCE.
= 32.55 A 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. dScn
14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. W Lo
SELECTED CONDUCTOR-#8 THWN-2 ...NEC 310.15(6)(16) 15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS , (f) N
SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND ARTICLE 0 co
SELECTED EQUIPMENT GROUNDING CONDUCTOR(EGC)_#10 THWN-2...NEC 250.122(A) 310.10(D). I'-1
16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE
DC SYSTEM VOLTAGE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10(C). '
i
W
MAX OPEN CIRCUIT VOLTAGE(-DC TO DC+) INVERTER SPECIFICATION o
=NO. OF MODULES/STRING x Voc
=9 x 41.75 MANUFACTURER SOLAREDGE INVERTER co
375.75 V MODEL NO. SE6000H-US 0 0
F
MAX.OUTPUT POWER 6000 W W v
CC w
MAX.AC OUTPUT VOLTAGE 240V 0
MAX VOLTAGE DROP CALCULATION AC OUTPUT CURRENT 25A
z
ONE WAY %VOLTAGE DROP= OPTIMIZER SPECIFICATION w
CABLE SIZE CABLE DESCRIPTION DISTANCE IN BRANCH RESISTANCE OF VOLTAGE (V) (0.2*D*I*R)
CURRENT(I) CONDUCTOR(R)
FEET(D) /V MANUFACTURER SOLAREDGE OPTIMIZER
#10 THWN-2 PV ARRAY TO 20 15 1.24 375.75 0.20 MODEL NO. P401
INVERTER OPEN CIRCUIT VOLTAGE(Voc) 6DV PERMIT DEVELOPER
SHORT CIRCUIT CURRENT(Isc) 11.75 A DATE 09/28/2022
#8 THWN 2 INVERTER TO 110 25 .778 240 0.16 MAX.AC OUTPUT CURRENT 15 A DESIGNER OPT
MSP
MODULE SPECIFICATION REVIEWER
MANUFACTURER SILFAB SHEET NAME
MODEL NO. PRIME SIL-370 HC WIRING
OPEN CIRCUIT VOLTAGE Woe) 41.75 CALCULATIONS
SHORT CIRCUIT CURRENT(Isc) 11.25
RATED VOLTAGE(Vmpp) 34.95 SHEET NUMBER
RATED CURRENT(Impp) 10.60 E-0 2
MSS Z022-co3(7
iI
ELECTRICAL SP£C#F#CAT#ONS 4, �. ., . t;; 1 f,i.: 0 ''%h Signature with Seal
lest Conditions SIC NOCT
Module Power(Pmaxt Wp 3 0 276
Maximum power voltage(Ypmax} V 34.95 32.48
•••
•.0•• Maximum power current fipmax; A 10.60 8.50
• • Open ctrcuu vo{tage Noy V 41.75 39.1fi GPEEN P1DGE
Si LFA B PRIME SI L FA • Shq c+r<blt current,isc, A 11.25 9.07 w
S O L A R4, Module efficiency - ' % 20.2% 18.9%
Maximum system voltage{VDC) V 1000
:. ' ...__., Series fuse satin A 20 ADD:19450 SW MOHAVE CT.,
g TUALATIN,OREGON 97062,USA.
` "-».,,, Power Tolerance Pip 0to+10 CONTACT:503-395-1943
-.. ..ry Measurement gond/boos SIC 1000 W m AM 1 Temneratu re 29 tC•NOCT800 WIm AM Measurement taxertatotty o 9N,
''w tot o1 atro tn tie d .,rob tette mo.,r nrn ..a,, a, +r.s,tv.c tore cs shatactoce tot mac get,no Into and Poor 6}9to.t CU1.
"` � "Kay' I
MECHANICAL PROPERTIES t COMPONENTS ETRPC 1MPUILER , ac.'• s ` qi,
>y
,Oa;,,(weight 19 Skgx0 2kg 43tbs nOD 41bs f t'S
Dimensions{HxC C 77fi2 mmx1C37 mm x35 mm 69.4 in 401.8 in 1.33 in V/
Maximum surface load Hvindisnowl 5400 Pa rear load/5400 Pa front load 112.8 ib, rear load r 112-816/(C front load rY Q
Hail impact resistance m 25 mm at 63 kmjh o i to at 51.6 mph LL
120 Half cells Si mono PERC 120 Hatt cells-Si motto PERC Q
Cells 9 bosbar-83 x 166 mm 9 busbar-3 26 x 6.53 in UI
' 3.2 mm high trarsm{Manes,tempered, 0.125 high transmittance,tempered,
Q QSM antireflecti ecoatng DSM antireflecttve coat ining (vim
Cables and connectors(reter to installation manual) 1350 mm,a S.7 mm,MC4 from Staubli 5315 on,00.22 (12AWG),MC4 from Staubi (. ) Z
High durability,superior hydrolysis and UV resistance,multi-layer dieleclric film, —IBacksheet fluorine-free RV backsheef III Y
frame A 04 zed Atumin mielack, J N
.,
Bypass dio -Cr)�des 3 d odes 305Q0457 451 ar 0 �t k b voltage 30A maxforward rectieed current]
lunccon Box tit 3230 Ceref,cd,IEC 02s Cel ttes!,{F6&rated Cr) O N
- . TEMPERATURE RATINGS ". `; WARRANTIES ' s " I,I Ce O Q)
7,,Ipe,atUIC Co,h,,,I isc :,old=.„-C Motto,pote -.,r}nar eery 25 Years'" Z
0
-Temperature Coefficient 001 028 C t wee power perfomance guarantee 30 years
Temperature Coefficient Pmax -0.364;'(. ?91,1`,ro end 1st yr OZI
NOCT{t 2"C; 45`C _91.636 end 32Tfi yr (n
. . >_85.130 end 25th yr
Operating temperature -40r 85 C >_82.6%end 30tfly L�/J A
CERTIFICATIONS 4" i xaax s-a, t,v,x. c5 :P ' V N
OLC080C1703,UL1703,CECIsted,UL61215.1,4,U26r.301/2,iEC61215-1f-2-lDC Modules Per Pallet: 26 or 26 tCafrtomaJ j
Product 61730-1/.2,C5A C22.286173C-1/'2,IEC 62716 Ammonia Corrosion;16061701:2011 Self 11
Mist Corrosion Certifed,UL Fire Rating:Type 2 Pallets Per Truck 34 or 32(California)
Factory 1509001:2015 Modules Per Truck 884 or 832(California)
" AWarning.Read the Solely and installation Manual ton mamt{ngspecifications and before handling installing and operat,ng modules.
" 12 year extendable to 25 years subject to registration and condltionsout/oed under"Warrantv'ai in Ali
PAN file,generated from 3rd party performance data are avaAable for download at n4taew to Veer8. ^Snsd+ Q
0
i in
„ - r _. 69.4"[1262mm] _.__1 p O
14"[356mm1_.,~ 41.3'[1050mmJ 14"[356mm]. a re so
o
RELIABLE ENERGY. Mounting Hole(x4> s1i gas SOLAR INC.
.a . 80o Crnall Ave w
DIRECT FROM THE SOURCE "
, 7+1360.569.4733 >
introducing Sitfab Prime. I # nfosilfabsotar.com it
E 177o Port Drive
Designed to outperform. ' 1.4"[35mml, ! t^E, ti
�::' — o r io to a> BurtingtonwAs8233OSR PERMIT DEVELOPER
O u
Dependable,durable,e high-performance solar panels 4 <, A v 7+1360.569.4733
engineered for North American homeowners. w o a 240 tourtneypark DriveT23 East DATE 09/28/2022
3 Mississauga ON L5T 2y3 Canada
Si L F A S S O 1 A R.C O M o5mm 53.15" nvO T+1 905.255.2501 DESIGNER OPT
`.� ( ] _ -.... (1350mm] 61 � F+1905.596.0267
' . Cable Length k. 2 REVIEWER
CS 5iirab-5#L-370-NL-20220701
7` o
nerepmar nr ray 4.1.al,mwedwlthait
�.�, ` r.. Drainage Hole(x8} t4 w,nr' ,Data as Anna b.11,0,10
s SHEET NAME
- - s 24"[60mm] 8"[200mm]
, _ MODULE
DATASHEET
SHEET NUMBER
DS-01
2022 -003(7
r.
•
I Power Optimizer
1-13 For North America
P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Signature with Seal
•
Power Optimizer
0 ,
P370
P340 (for higher- P400 P401 P405 P485 P505
For North America Optimizer model P320 (for high- Power (for 72& (#ar high {for high- {for high- (for higher t I i t�f t l
(typical module (far 60-cell power power 60 t
60 and 72- 96 tell voltage voltage current
P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 compatibility) modules) 60-cell t 72 cell
madtstes) cell modules) modules; modules) modules) modules)modules)
ADD:19450 SW MOHAVE CT.,
INPUT TUALATIN,OREGON 97062,USA
Rate( CC P we r 34C..- ..-_3(' euc ACS -. _ 50 .__ th_. CONTACT.503-395 1943
Abs25 7aolute Naxtirur^Input Voltage48 60 80
60
1?5-'" 53'2 Vdc
tVo a Lowest temperature) _ _ _...
MPPT Operating Range �— --�$-48 8 60 $ 80 &6C -- is 5 105 ___. _ 12.,4.53 Vdc_--
YEAR Ma ovum 5hatt Circuit Cu ent —__ —_—
Y1 10.1 ' 11.75 5 14 , Adc La
WARRANTY0 ('Sc) _ I W
Maximum Efficiency _ 99.5 �+ I2C Q
~ - Category
------_ _.- ------ ----
. ... MO Weighted Efficiency Cat _ _ a$8_ -------- ---_---- �__98.6_ %
fir....... , Overvo! Ca li
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
. Maximum Output Current'! Maximum Output Voltage -.. °" c�c _.._ __ '� . - _.. z
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) ! Z —I D
��� Safety Output Voltage r'ae Fower 1 s 0' vac FL-1 Y
Opifmfzet----,_-, I— O N
/ STANDARD CQMFUANCE — __-----------. __ ----- U_
CV
, =me EMC FCC Parris Gass B,)E.31130-6-2,t£C61000-6-3 „� On
Safety 18C52109-'floss safety),t1L1i41 --- _
-r-- ---- ----- ----_- --- '-- -- -' ----
Matertai Ut94 V C,UV Resistant
RQNS Yes 1
mINSTALLATION SPECIFICATIONS CO
Maximum Allowed System 77 1CCC - Vdc
— I LO'Voltage
Compatible inverters Ai Scaartdge Single Phase and Thr e Phase 4rverters 0 c0
1129x153x33.5 129x153x295f 129x162x59 ! ram n
Dimenuons(W x L x rl) i 129x153x275/5.1x6x13 (9.1xbx 13 157x6xt16 129x1s9x49.S-/5.1x83x1.9 51x64x 23 nu
Weight(including tables) 630/14 750/7.7 655!1.5�_ 845/1-9 1064/23 gt/lb li
Single or dual {4o-.
Input Connector MC4.
MC4MC4"-FAM,.
Input Wire Length 1 C 16 0.52 .'> a
Output Wee. yoe!Connector k Doable insulated/MC4
Output Wine ength j 09/2.95 s _-------12/39 ----------------- --_ -- - ns1ft
Operating Temperature Range" 4C 85 f 40-+185 C/,£
Z z
-- .__ ... 'P68'NEMA6P 0 0
PV power optimization at the module-level Protection Rating _ �,
RelatveFlumidi - — - 0-10G % 5 re
Lt w
0
/ Specifically designed to work with SolarEdge I Fast installation with a single bolt CPRatenp5 mtt)them«5B'eatSTCwil;rtotexceedtne`pt'r t'katAdmp.°cP`vse'°Module wit)aPte-5%tocw'ertaera°oe are a'rswed
(Z)NEC 201,requires max opus cottage be not mote thaw 8PY
inverters t r other oo as type^Prey contan sowEage 0
I Next generation maintenance with module- (4 Po,'dual v,sio for paraSe connector.of two r4Ddlles tse P485-ANMDMRM thA cis, i a.d n;m"to CAP'modules,n net.e9,333o, ope P48.,dJ2,-aErs,Oc power Optr's er cowecten 0
to one PV rnooute When ro nect t o a sing e module saes the urxnei Input connect-Po win,ere susp ied pa3 ct seah w
I Up to 25%more energy level monitoring (5)Poram6;e .,t at,..nabo SIC!.155°power derat,ng sapprey tie io Powetc Power Opp-rae<,thm: attire.oePatng;ecttrra.Notets-s re details
ui
re
I Superior efficiency(99.5%) I Meets NEC requirements for arc fault Pv System Design Usula Single Phase Three Phase for Three Phase fop
{
cue pra5C
protection(AFCI)and Photovoltaic Rapid a SolarEdge InverterND-wave 208V grid 277/480V grid
I Mitigates all types of module mismatch losses, P?o,P34C,P37o. PERMIT DEVELOPER
9 YP Shutdown System(PVRSS) M,nr.,ur String Length P .P401
from manufacturing tolerance to partial (Power optrr er. FaS Paas,ase ___ 8__ 4- DATE osizanoz2
— — —
—
shading t Module-level voltage shutdown for installer Maximum Siting Length(Power optimze ) 2525 50°
and firefighter safety 5/0 t6005 garf DESIGNER OPT
1 Flexible system design for maximum space tsaximum Power per String 5E7600US 5E11400- 5250 60050 1t750'x' W
US'
utilization REVIEWER
Parallel Sm tg of Different Length,or Of lent9ttons Yes
(5)Fe,detailed lot.song nhnmat;a r refer to.httornAnwsolaredge.com/sAestOefau9/Ake3t.qnog).s.zing_Aa.pdt
v t Y,tot atirwed tO too P4 a 5/853 P 4.P P4 P4. one O g SHEET NAME
(5)A wing wttl mole 9...r 3 optroopo dry-no, eel NEC Pap,MadloWneqo..emrmts o39.9.A w3 op a0c-e th: 0 requ cement
Fry 203V q t:wan tc up 7 V:F' s 41 t e ma rum pow t e rwtwe s' f
OMF.2i7r ogJ . >wo-tt .1059 whnthe a'.,.tti t rot ,ee set: 0000W OPTIMIZER
sotaredge.corn Solar,, C' 11 i £ i 1 DATASHEET
SokefAgt T chndog lid.A re d.SOLAREDGE.the So rEdye rage OGTIKZED BY SOLAREDGE trademarks eegimered trademarks ei SolarEdge Tecmotomex inc. RoHS
At Wirer trade ks mar mermoned herein are txadenrk mv of then respectrx owners.Date-07/Z02DN02/ENG NAM.Subtect to change wrthvwt',One RoHS
SHEET NUMBER
DS-02
/VlS!2.D22-t7
'... Signature with Seal
__- — EiN PI f
/Single Phase Inverter with HD-Wave Technology
I
_ !Single Phase Inverter with HD-Wave Technology 9 9Y
» for North America for North America ADD:19450 SW MOHAVE CT.,
Single Phase Inverter SE3000H US/SE3800H US/SE5000H US/SE6000H USI TU CONTATIN,ORE50N 3-395-1943
SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/
with HD-Wave Technology SE7600H-US/SE10000H-US/SE11400H-US SE7600H-US/SEI0000H-US/SE11400H-US
mMODEL NUAF r.:.n SE3000H-i5 SE380(iH-US 555009H-t}S SE60006-US SE7600H-US 5Et0000H US SEitaooe-US MODEL NUMBER 5E;000H-US 5£38006-US 580080H-US SE6008H-US SE7600H-US SEI0000-US SE11400H-US
for North America +T7 nwuCABLETOINVERrnu Ac,A TIC A, .rn;RIS
'/V wax PART NUMBER SE7iXXXH.XX7(X1(6%Xd t ,
SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-USI oUTPu1
SE7600H-US/SE10000H-US/SE11400H-US �. ,. p
FCC
2 25 ..<. '� DARCOMPLIANCE
,: S AN ,. .. .. r,-
0 .,..=..r CO
V"1 t�
0 a INSTALIAT:ON SPECiPsAT SONS Q
- - a
—I D
,
a _J
L �,ti_
J N
INPUT ._,_. _...... -. ... -
/nCV
nA9teperaueR e w�fpr _ .A u4 `t
_ ,p £,' -TO c e A..a4dr u o ... aadm amr,P .- _. .:sue)s«�w» ...
.. f�r Y .. p.. 3 a;wnnNA Rw�ra time uums RsrvNtii's.(@M : xx Nonni... .,.,hav rM kvN+�59 <b>ams-}tte�.mtm„rym xMrNn..e:, O
... : -en v w,,,NN Vrrea..aNtv.2,.. .,,+.:r.+m,
e ss w,'tiro*Pwn.ro«xm,z':x:.cow..a..meg: sc�rtr�-..�o,.-.., »+,:�.ma,an�v�-r«va.«+ cerwr+v=-a Z u
m O
e How to Enable Consumption Monitoring 025
By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service W in
». ,� o a n panel,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills A -r
- • '' f
V I N
0 CO
,. .. .: SingleInverter phasew 1, r1
Optimized installation with HD-Wave technology 9Y D e t t of „And
built-in RGM and
I Specifically designed to work with power optimizers I UL3741 SA certified,for CPU(Rote 21 grid compliance Service Panel consumpzor +onnr,nr.y
Record-breaking 99%weighted efficiency I Small,lightweight,and easy to install both -- .�._ w
outdoors or indoors ,rid - F
Q
I Quick and easy inverter commissioning directly from j _ o
a smartphone using the SolarEdge SetApp i- Built-in module-level monitoring 111 N ta?
i•_� I Sh r rs,- is
F Fixed voltage inverter for longer strings I Optional-.Faster installations with built-in # ¢ -- -'"� -. -d._,3 CO z
consumption metering(1%accuracy)and a a • I I r, O O
I Integrated arc fault protection and rapid shutdown production revenue grade metering(0.5%accuracy, ! pj 7 -- -- j' fA a
l d
for NEC 2014,NEC 2017 and NEC 2020 per article ANSI C12.20) ,,.r„, y 690.11 and 690.12 w
1 0
sdaredge cam solar- • . : ..,.,m . ; b.�smomwv .
I w
w
to
PERMIT DEVELOPER
DATE 09/28/2022
DESIGNER OPT
REVIEWERL....
SHEET NAME
INVERTER
DATASHEET
SHEET NUMBER
DS-03
•
144STZO2.2&53�e7
k.
FlashVue TM See Your Pilot Holes Signature with Seal
.�',1i IRONRiDGE yg#1
S �'
e trri in Flashing • ''= ? , ' .,a ,' ,� r f pis`, s'
Moving Flashing Forward �. rn g �; P ,� ' Gi ►P� 0.,i t eiasiiVor makes pliot hoes n")ghlt
i � :
.c)ntr.'v<i<e never betel No mire t'�a,,_: '�
4v:•a, """.,,.�. tedlcus o,ipssi'.r-. on hot roots • ,rr.?,,,•w*'"'r"`" *s,...• �,.. f:
We set out to design a flashing that checked all „ ADD: SW MOHAVE CT.,
the boxes:fully waterproof,fast and easy to install { I I TADD:19450,OREGON 97062,usa
correctly,economical,and strong enough to handle . CONTACT:503395 1943
every environmental condition. FlashVue does it all. . . t ` rK, .
i
The optimized flashing design features a large c,
viewport,for easy alignment with the pilot hole.And
W
the GripCap and GripCap+sit snugly in place,so C! 0
the lag can be driven single-handedly. i,I,� Q Et
__I CD
. 0 1
U) Z Q
Solve Roof Undulations H o N
Three-Tier Water Seal,Reimagined g"" "" u_ "
-r,z•5.45,,,..--nit:RW'l :':,!-.4.: FlashVue's seal architecture utilizes three layers li-u '- „s` ~ 0
of protection.The viewport is elevated 0.30",and Alto Available:GripCap+ C
P o ^ provides a"friction-fit°for the GripCap.The GripCap 0
[ 4 k Vie t+n.i.roots are not FIC.ys ,:
4 fully covers the viewport while a sealing washer �11 fiat GripCap+can tzrt
¢ adds another layer of protection.And an EPDM t l (n
• MVMpn undulation;apt in trip way,
. �. ' washer and lagbolt"seal the deal"in the stack.
" Cler CV -, :..w.. . W
N
} 'lam" -} .'t 2"
GripCap&GripCap+ �� �"�
„�"" - "tis E�x 5
'll
The 360°capable GripCap(2.74" �„ .-+^ r r� 3 s � ' ' . —-
�:,, €
tall)and GripCap+(3.74"tall)can be a '.,
ul
placed in any orientation,and provide a �� o
"friction-fit"for easy installs.Push snug ,a _ 1"
ort .
into the viewport,without worrying it will �r s roll away or rotate while driving the lag. V t,r „
r 1,, ;, ,,. . 4 N
f,, O
a
CC 2
d
Trusted Strength &Certification
Z
W
75"
) ,
�� I .:-,,-:,,, . all Attachment Loading
FlashVue has been tested and rated to support 1161 (Ibs)of uplift and 353(Ibs)of lateral load. i
j - .s
ElStructural Certification PERMIT DEVELOPER
Designed and certified for compliance with the International Building Code&ASCE/SEI 7. DATE 09/28/2022
ei.s - '.... „
—•,.: Large Viewport in Flashing
Water Seal Ratings DESIGNER OPT
The large viewport makes it easy tocii
Intertek
align the flashing with the pilot note,and Passed both the UL 441 Section 27"Rain Test"and TAS 100-95"Wind Driven Rain Test"by Intertek.
Triple Certified to drive the lag centered into the rafter.The REVIEWER
Protect the Roof elevated rim not only provides a sturdy (Jt,2703 Listed System SHEET NAME
ti + but
dock for the GripCap or GripCap+,,
o P p
UL 27 3.441 27
P P
0 { )
TAS 100(A)-95 increaseswater-sneddmg capabilities. Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. ATTACHMENT
DATASHEET
'£,, "'`'� - + ?.b2o froriRiAoe.Inc.Ali rtg»ts resenveri,visit www.ir+ora+dge.cornof can t- #r-227.8523 tor more iMomiatttS8.version 1.0
... ---_- -----.
i .. "_ s���f..r. . SHEET NUMBER
DS-04
/pis T Z. 2 -053G7
1
.�., .1 L IRON RIDGE XR Rail Family XR Rail Family Signature with Seal
The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
Solar Is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rail to match. BEN POSE
Over their lifetime,solar panels experience countless _
extreme weather events.Not just the worst storms in years, ADD:19450 SW MOHAVE CT.,
TUALATIN,OREGON 97062,USA.
but the worst storms in 40 years.High winds capable of - ^-""""""` CONTACT:503-395-1943
lk
ripping panels from a roof,and snowfalls weighing _,_ ` • - '
enough to buckle a panel frame.
XR Rails are the structural backbone preventing , . (I)
these results.They resist uplift,protect 1 " ' XR10 XR100 XR1000 !1J
against buckling and safely and efficiently A r , El t
y� �. T XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among <
transfer loads into the buildingstructure. Q Q
�� r '�. � ,� w � rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle � J , �
Their superior spanning capability } ; no snow.it achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 _
requires fewer roof attachments, A 1r while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. 0
reducingthe number of roof ��
� y � ; T i • 6 spanning capability • 10'spanning capability • 12'spanning capability � z Cl)
penetrations and the amount , �,, • Moderate load capability • Heavy load capability • Extreme load capability Z J D
M
of installation time. •«. # • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish t—+ Y
Internal splices available • Internal splices available I
• Internal splices available /— O N
LL N
F�-I IY• Rail Selection ice o c
Y z O
.Y The table below was prepared in compliance with applicable engineering codes and standards.*Values are p�
based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof
Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. tLn
N a co
'" Load Rail Span �-,
Sndw(P59 Wind(MPH) 4' "�"•' 12'
v
Force-Stabilizing Curve 90 W
......::.:
Sloped roofs generate bath vertical and lateral
Q
,,tip forces on mounting rails which can cause them 120
to bend and twist.The curved shape of XR Rails None g
t - is specially designed to increase strength in both 140 XR10 XR104fl O z
$ f directions while resisting the twisting.This unique f
feature ensures greater security during extreme 160 'tom �5 _
weather and a longer system lifetime.
90 `% ' =rx. _ r O
120 : ., l;
. 20 e
fxi{
(7
140 e z
ate- .� W
160 >
90 k2 lcr
w
�yy
160 tl, '�+ - PERMIT DEVELOPER
Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 a 3; , £ "
XR Rails are IronRidge offers All XR Rails are made of 6000-series - I 40 ' ' DATE 09/28/2022, ��
compatible with a range of tilt leg aluminum alloy,then protected with an 160 ° T
FlashFoot and , options for flat anodized finish.Anodizing prevents surface DESIGNER OPT
(.1.
other pitched roof t t roof mounting and structural corrosion,while also providing 80 160
attachments, applications. a more attractive appearance. 111110: _— �� Y
REVIEWER
120 160
cw t.
".us , :�c,., ..,. ,n cy::n-g gyro„"ro s; r.wttes_Use a, ^;,e cs ,,,c s1/./k _..,I a0,,,1,<,i9r p,trlan SHEET NAME
• RACKING
0 2020 I Inc.AN DATAS H E ET
I NW** .1 saiNw.trwwlifge.cmn ar c t-aoas2r-a5s3 for ream irdannatian.Persian t.Za
,
SHEET NUMBER
DS-05
,
lM,sT 202z-06%1