Plans (3) ' SCOPE OF WORK: GOVERNING CODES SYSTEM RATING TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE 2021 OREGON RESIDENTIAL SPECIALTY CODE LOCATED AT 13664 SW AERIE DR TIGARD, OR 97223 2019 OREGON FIRE CODE 8.40 KWDC o THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY W v 2017 OREGON ELECTRICAL SPECIALTY CODE 6.30 KWAC 3 W GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 2019 OREGON STRUCTURAL SPECIALTY CODE ',,,s N ~ THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES - m co EQUIPMENT SUMMARY UABILITY SHEET INDEX 0 w i_o N The City of Tigard and its PV-0 COVER PAGE `�-` (L z z w o ' N PV-1 SITE PLAN :. z "*` 21 REC400AA PURE BLACK MODULES employees shall nit be PV-2 ROOF PLAN&MODULES Lj w' -a J 21 ENPHASE IQ8PLUS 72 2 US(240 V) MICROINVERTERS responsible for discrepancies Approved plans PV-2A STRING LAYOUT&BOM a which may appear herein. shall be on 'of) SIte. PV-3 STRUCTURAL&ATTACHMENT DETAIL GENERAL NOTES: PV-4 ELECTRICAL LINE DIAGRAM&CALCS. • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND PV-4A SPECIFICATIONS REVISIONS OTHER INFORMATION AVAILABLE AT THE TIME.ACTUAL FIELD CONDITIONS MAY REQUIRE WIRING AND CONDUIT NOTES: PV-5 SIGNAGE DESCRIPTION DATE REV MODIFICATIONS IN CONSTRUCTION DETAILS. • ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PV-6+ EQUIPMENT SPECIFICATIONS REVISION 06/09/2022 A • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR PURPOSE AND APPROVED FOR THE SITE APPLICATIONS INSTALLATION OF ANY EQUIPMENT AT SITE. • ALL PV CABLES AND HCMERUN WIRES BE#10AWG"USE-2, PV • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND BOXES AS REQUIRED PROJECT SITE 1 COMPLETION OF THE WORK WITH APPROVED MATERIALS. • ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING ACCORDING TO [NEC 690.8(A)(1) &(B)(1)], [NEC 240] [NEC PERMIT IS PROPERLY DISPLAYED. 690.7] FOR MULTIPLE CONDUCTORS =" §' • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT Signature with Seal WITH THE REQUIREMENTS OF THE OR BUILDING CODE, THE DEPARTMENT OF SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. (B)(2)(C)] BLACK ONLY** w xi.. IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE 2, 90°C - • PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. RATED,WET AND UV RESISTANT, AND UL LISTED RATED FOR ''" THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT ."'"° � • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE WIRE FROM SHARP EDGES .. LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED PROJECT NAME&ADDRESS • THE CONTRACTOR SHALL OBTAIN ALL PERMITS,APPROVALS, AFFIDAVITS, THHN/THWN-2 INSULATL-D, 90°C RATED, WET AND UV CERTIFICATIONS, ETC.AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. RESISTANT, RATED FOR 500V PER NEC 2008 OR 1000V PER ELECTRICAL NOTES: NEC 2011 O • THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE • 4-WIRE DELTA CONNEC ED SYSTEMS HAVE THE PHASE WITH INSTALLED ONLY BY QUALIFIED PEOPLE.A QUALIFIED PERSON IS ONE WHO HAS SKILLS THE HIGHER VOLTAGE l O GROUND MARKED ORANGE OR • AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE IDENTIFIED BY OTHER EFFECTIVE MEANS U ch LO cB ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING TO • ALL SOURCE CIRCUITS HALL' HAVE INDIVIDUAL SOURCE - p E (NJ RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(E)AND 705.6) CIRCUIT PROTECTION I- W W N • LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY • VOLTAGE DROP LIMITED TO 2%. 1 IY 0 E CD O PV-0 HOUSE PHOTO SCALE:NTS M SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONNECTION, UTILITY • AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE 0 Z W v NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT A OR L1-BLACK, PHASE B OR L2-RED, PHASE C OR L3-BLUE, I W Q 0 CO OFF. NEUTRAL-WHITE/GRAY _a 0 • NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL ° W U) I �t VALIDITY OF PROJECT SITE LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF PERMIT ' � " °' '` Q W g Q E 2Etco � Os OTHER TRADES. THE ISSUANCE OF A PERMIT s ���� x� tr9� 0 co 1- Z • ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED BASED ON CONSTRUCTION ' p M�F.� °°T` — _ —� PERSONNEL. DOCUMENTS AND OTHER '. , OFFICE ICE COPY Q • ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED p,gTA SHALL NOT PREVENT HEWHEQRS 50UT4WEST d FOR USE IN WET LOCATIONS. (NEC 314.15A). THE CODE OFFICIAL FROM LU • WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF ein AISry F3 F91 iCc,.? THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE RE.QU1RING THE CORRECTION '- " C3 " OF ERRORS. ORSC 105.4 CITY OF TIGARD ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT `=_ '~ REVIEWED VWW ED FOR ODE COMPLIANCE DATE:06/09/2022 WIRING .,. • ,;;. = r • BACK-FED BREAKER MUST BEAT THE OPPOSITE END OF BUS BAR FROM THE MAIN � __ SHEET NAME At��rcwed: - BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. w COVER PAGE • ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV I RESISTANT. (Y�SI ZvZ2 �O I 4�rt�t�t#' '''' h�� • CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS e w-, ` 9 SHEET SIZE IN NEC 690 AND IFC 2015 Ai*f ss: 13L9W-1 SW pc-tr.► Dr ANSI B • PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF S,li��, #. TERMINATION, CONNECTION,AND SPLICES. THE MEANS OF ID CAN BE SEPARATE COLOR x' 1 1" X 17" CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4). r): �Date: 724 i2..--- O - • MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE 2 SHEET NUMBER ENTRANCE CONDUCTORS PROIR TO INSTALLING ANY SOLAR EQUIPMENT. THE PV-0 VICINITY MAP SCALE:NTS VOLTAGES FOR THE 240VAC RATED. PV-0 SITE NOTES • THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITHOUT STORAGE BATTERIES. Cr y o • THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR UJ W BUILDING ROOF VENTS. 3 111 o • PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED s w c)N ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26] Q o 1E o N QA Z O t-o N Z lJ Z W j-I m � dr w 0_ a a \ `�- (E)MAIN SERVICE PANEL 1 1 41,.7111 L(-(--- �' — TREES ( \ \ - - .. — — T — — — PROPERTY LINE REVISIONS \ \ ) CO DESCRIPTION DATE REV \\ _`~'/ \ REVISION 06/09/2022 A E.( J m j--)‘ ) MSP , 00 \r - \ h�\ Ir I `\\)I Signature with Seal �_ CO r . I (E)DRIVEWAY In" I I I r \y 1 . 0 PROJECT NAME&ADDRESS ___Cirl ,---- D (,..____.7- ---„,,,, --.....N --) w I J \ C--r-- I O IeZ C \ I � -� I \ D _ co rT3 Q \ \r \ \ D N \\ , 51-8" C \ \ `\ / , w U Fr rn M ��\ 2-STORY �� J�/ \ \ Q Z Q oW c_N HOUSE a \ = W O �, (E) PATHWAY \ I 0 O �� I \15'-9" _ oa \) = � 1- < •• 0 I- Z \ _ j \r 4 > \ W> I \ y_i N DATE:06/09/2022' SHEET NAME RTY LINE — — - - - - - - - - - SITE PLAN ,_, ... ROOF#11 (E)FENCE 41 " SHEET SIZE �V �� (14) REC400AA PURE BLACK MODULES .3 �� � 4._k��� (7) REC400AA PURE BLACK MODULESROOF#2 1 ANSI B 11" X 17" 1 PLOT PLAN WITH ROOF PLAN SHEET NUMBER PV-1 SCALE: 3/32"= 1'-0" PV-1 MODULE TYPE, DIMENSIONS&WEIGHT DESIGN SPECIFICATION ROOF DESCRIPTION NUMBER OF MODULES: 21 MODULES RISK CATEGORY: II ROOF STICK FRAMED STICK FRAMED ROOF MODULE TYPE: REC400AA PURE BLACK ROOF AZIMUTH # CONSTRUCTION: SFD TILT SIZE SPACING MATERIAL WI 3 N o MODULE WEIGHT: 45.00 LBS ZONING: RESIDENTIAL r W N #1 30° 270° 2"X12" 24"O.C. COMP. cn MODULE DIMENSIONS: 71.7n X 40.0"= 19.92 SF — (E) UTILITY METER SNOW LOAD(ASCE 7-10): 10 PSF SHINGLE ✓�o o N UNIT WEIGHT OF AREA: 2.26 PSF (N) ENPHASE IQ COMBINER BOX #2 30° 180° 2"X12" 24"O.C. COMP. �.Z z w o N EXPOSURE CATEGORY: B SHINGLE z - (N) FUSED AC DISCONNECT W w J ^ c� WIND SPEED (ASCE 7-10): 110 MPH ARRAY AREA & ROOF AREA CALC'S o w °' (E)MAIN SERVICE PANEL MSP c6 IACDI �a ROOF a #OF ARRAY ROOF AREA M ROOF AREA AREA COVERED MODULES (Sq.Ft.) (Sq.Ft.) BY ARRAY REVISIONS (%) DESCRIPTION DATE REV #1 14 243.09 2360.10 10 REVISION 06/09/2022 A 1 #2 7 99.15 2360.10 4 I I TOTAL ROOF AREA COVERED BY ARRAY(%) 2360.10 14 I LEGEND JB -JUNCTION BOX 1 n -IQ COMBINER BOX 1 mg -MAIN SERVICE PANEL I um I -UTILITY METER Signature with Seal ACD -FUSED AC DISCONNECT 3'-6 O❑ -VENT,ATTIC FAN(ROOF OBSTRUCTION) t ----- --.- El15'-7" / •----CONDUIT ACHME NT -------RAFTER -- (N)3/4"EMT CONDUIT(IN ATTIC) .1- I: W PROJECT NAME&ADDRESS w 00 - i- z U I w z o o -• --1-•-♦----•-- W II �/ (f) (N)JUNCTION BOX - = M `co OD oz A— - •--it_-.-fi--�__-_ O N a� w — • . • •ILI "N I— Wwl- p Q 0 __ __ Zji Q REC400AA PURE BLACK MODULES O WH Q O M N z 'm 1T1 0.2-,3.4 in 20.5-256 in 25.6-20.6 in ,3.4.8.2 in p i . .---[(yt( �\ IR-420© ISa26650-0mm] [650-520 mm] [420.340 ] O ROOF#1 IIIm'm a _64�� — ' O OA2n 8.2134 r6.5-25.61 266-165i{ 134A.2 in 82-0in W (n � s () TILT-30° w az°am] [zo6-340-0 H� � �� [ [+�620�,] [-�42o�nr 1 I340zoe mm] [zoe o mm] Q AZIM. 270° - --- ir-- ---- —fin 2 Et CO 0 ,L w MI co M 7 i J co �I N t CL Q CV _ __It__ -•--; 1 I I I I 3m C 2"X12"STICK FRAMED @ 24"O.0 I I I I 1 1I I I _ (21) ENPHASE IQ8PLUS 72 2 US(240 V) 1 1 R T 1 1 T 1 1 j MICROINVERTERS = 1 1 ; I I 1 1 1 -00 N DATE:06/09/2022 p I�+ I I + i i I — SHEET NAME oo ---- t 1+ I I ; �1 I - M �� ROOF PLAN & 1 I�� 1 1 ��� E MODULES 6 / 6 -� / e JN SHEET SIZE ( d $ 1 13 -5 .� , ; �, TOOF3 2 D (50)SNAPNRACK ULTRA RAIL ATTACHMENT ego _ 3; ANSI B @24"O.C.WITHIN / �� ��36"OF RIDGE/EDGE/HIP, ' 11 X 17 AZIM.-180°414.0" @48"O.C. EVERYWHERE ELSE ° b ; °''\ 1 ROOF PLAN & MODULES c� �. SHEET NUMBER ROOF#1 &#2 0.206 mm] (208-3304 m] [�20.6206 i) 26-426[ , 40-20 2 in 08-0 m PV-2 SCALE: 1/8"= 1'-0" (21)REC400AA PURE BLACK MODULES 3404 a2042�' °-2°6mm, [2°6-°mm, PV-28.24 40-.0 in 20.-650i in 25.-205 20-340 mm] ]520.650 mmj [660-620 mm] [420-340 mm] 1$i 224 cCfc _ BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION 0 SOLAR PV MODULE 21 REC400AA PURE BLACK 111 . INVERTER 21 ENPHASE IQ8PLUS-72-2-US(240 V)MICROINVERTERS c w - N JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED m C COMBINER BOX 1 ENPHASE IQ COMBINER 4C W/IQ GATEWAY(X-IQ-AM1-240-4C) o It ")o N a, 60A FUSED AC DISCONNECT, (2)40A FUSES,240V, NEMA 3R, UL a z Z w z AC DISCONNECT 1 uM cs IACDI w w,, N U LISTED w _1 e 7, ATTACHMENT 50 SNAPNRACK, UMBRELLA LAG, TYPE 3,41N, SS msPp a O ATTACHMENT 50 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER/BLACK Lo ATTACHMENT 50 SNAPNRACK, COMP FLASHING, 9IN X 121N, SILVER/BLACK ALUM ENPHASE Q CABLE 28 ENPHASE Q CABLE 240V, (PER CONNECTOR) BRANCH TERMINATOR 2 BRANCH TERMINATOR I REVISIONS DESCRIPTION DATE REV WATER TIGHT CAPS 7 WATER TIGHT CAPS REVISION 06/09/2022 A RAILS 11 SNAPNRACK UR-40 RAILS RAIL- 14 FEET, UR-40(168") BONDED SPLICE 4 SPLICE KIT CLAMP 30 MODULES CLAMPS(MID CLAMPS) CLAMP 24 MODULES CLAMPS(END CLAMPS) GROUNDING LUG 6 GROUNDING LUG ®0 - MODULE STRINGING Signature with Seal 113 PROJECT NAME&ADDRESS U z ,LI C) A-Q QA.-__.])1z ooz n L1 U OZ A-3 A-4 B-1 _ 'c� E QA-5 B-2 mmZI c 0 E rn oc) @1 z 0 0 zw � �.0 O0 A-6 B-3 m4Ti = W a O o IL D D U J - CS LOB O m Qw '-10 A-7 B-4 u W _Q \ I co -= _ A-9 A-8 = J IU�� w B-11 B-10 B-9 B-8 B-7 DATE:06/09/2022 SHEET NAME STRING 4./' VLAYOUT & BOM �� � SHEET SIZE ANSI B 11" X 17" 1 ROOF PLAN WITH STRING LAYOUT & BOM SHEET NUMBER PV-2A SCALE: 1/8"= 1'-0" PV-2A `11\57-Z022-=001t( • ROOF#1 ROOF#2 A BCr N o 0 SEE (2/PV-3) FOR 2"X8" RIDGE BEAM W -8 ENLARGED VIEW 5 F (r N O) ,gyp^ ,, 2"X12" STICK FRAMED @ 24"O.C. n�-1 6 ro (E)COMP. SHINGLE ©a o F O 2 .y. �N3 �N QP� O.z z w, a " c�2 QP � eP _BLS 37, 'I 2"X12" STICK FRAMED @ 24"O.C. W w Q " " W O> J SNAPNRACK �sQP �P� p. o w UR-40 RAIL -co -s0 a z PV MODULE Lo �� I,' REVISIONS � � DESCRIPTION9TE REV REVISIONON06/009/2022 A () CO I 1 ff— 7'-7" ---1—, 22'-8" ff- 7-7" f f�, ,110„ - f-� 4-11 ii 10-4 - 4-8f/ '` . 21'-4" f 1'-0" 12'-4" "I Signature with Seal LBW LBW LBW -/-'\r �-^r LBW 1 STRUCTURAL DETAIL PROJECT NAME&ADDRESS PV-3 SCALE: NTS �-PV MODULE I C :19E 4011°W o oc) LO A END CLAMP U OMSNAPNRACK, ULTRAO Z W1 , FOOT FOR U FLASHING, i w < a co +0 At* SILVER/BLACK J - 0 LU O / _ Et co I-U _ - - : 0.-1 SNAPNRACK, Q t UMBRELLA LAG, ��. TYPE 3,41N,SS LLB SNAPNRACK UR-40 RAIL DATE 06/09/2022 SNAPNRACK, COMP FLASHING,91N X SHEET NAME STRUCTURAL& 121N,SILVER/BLACK ALUM ZOff'Q ATTACHMENT 0,0* DETAIL �\cY °.' SHEET SIZE 5 ANSI B 2 11" X 17" 2 ATTACHMENT DETAIL (enlarged view) SHEET NUMBER PV-3 SCALE: NTS PV-3 • INITIAL CONDUCTOR FINAL CONDUCTOR #OF CURRENT-CARRYING TERM. ID TYPICAL CONDUIT FILL TEMP.CORR. CONDUIT CONT. MAX. BASE DERATED VOLTAGE LOCATION LOCATION CONDUCTOR CONDUIT PARALLEL CONDUCTORS IN PERCENT OCPD EGC/NEUTRAL FACTOR FILL FACTOR CURRENT CURRENT AMP. AMP. TEMP. LENGTH DROP _CIRCUITS CONDUIT RATING CC 1 2 ARRAY JUNCTION BOX 12 AWG Q CABLE 1 2 N/A N/A 6 AWG BARE 0.76 (54°C) o y O 0 COPPER N/A 13.3A 16.6A N/A N/A 90°C 45FT 0.55/o UJ a� MIN 0.75"Dia - THWN-2, 3 w F-0)2 1 JUNCTION BOX COMBINER BOX 10 AWG THWN-2 COPPER EMT 2 4 19.09% 20A 8 AWG 0.96 (32°C) 0.8 13.3A 16.6A 40A 30.7A 90°C 59FT 0.84% s D N COPPER _ FUSED AC MIN 0.75"Dia THWN-2, _ w N rn 3 1 COMBINER BOX 6 AWG THWN-2 COPPER 1 2 27.39% 40A 8 AWG 0.96 (32°C) 1 25.4A 31.8A 75A 72.0A 90°C 5FT 0.05% O II u)0 N DISCONNECT EMT COPPER FUSED AC MIN 0.75"Dia �.Z O F o N 4 1 MSP 6 AWG THWN-2 COPPER EMT 1 2 27.39% N/A 8 AWG THWN-2, 0.96 (32°C) 1 25.4A 31.8A 75A 72.0A 90°C 5FT 0.05% ¢ v DISCONNECT COPPER 0 ' z a a z U) U) M REVISIONS DESCRIPTION DATE REV REVISION 06/09/2022 A TO UTILITYL GRID BRANCH A 1 L2IN1 POINT OF INTERCONNECT BI-DIRECTIONAL UTILITY 10 REC400AA PURE BLACK MODULES LINE SIDE TAP O METER#24 318 802 Signature with Seal 1-PH,3-W,120V/240V / / / L1 LJ LJ • • • (E)MAIN BREAKER TO HOUSE 240 V,200A/2P PRODUCTION CT'S 4IE :7 4IE U U (E)MAIN SERVICE -' 4E7 ENPHASE Q CABLE — ENVOY - AC DISCONNECT: LZ PANEL,200A RATED, PROJECT NAME&ADDRESS 1-PH,3-W,240V T Q PJo�,°" 1CON5O1PTO° 240V,60A FUSED u` 20A/2P 0A 15A2P NEMA 3R, UL LISTED u u __.,___ </ _s..._.__.L1. - -_._�-.,.-_-. /� 2)40A FUSES /�m 0 0 L \ L2 1 -.-+-.«°.- ..L1 "j`«Lt } L1 Lt O BRANCH B — v-�'Lz 2 r— c� 11- REC400AA PURE BLACK MODULES j , -- I - 20 P _ cor — .� / / I ��7 L2 I ,, N K K 1 U M `n E C _ 3 4 CV � - c � LUw � rnaA • • • JUNCTION BOX (� O 600 V, NEMA 3R, iii UL LISTED — 0 Z < O M J a 0 O 0 __ 4E.7 � _ EXISTING GROUND _ / (N)ENPHASE IQ ELECTRODE CONDUCTOR LLJ COMBINER 4C Q w Q • E m ❑ ❑ ❑ n (X-IQ-AM1-240 4C) WIRELESS COM KIT = Et Cr) _ O V (N)CELL MODEM C G (21)ENPHASE IQ8PLUS-72-2-US(240 V)MICROINVERTERS — W DATE:06/09/2022 SHEET NAME ELECTRICAL LINE SERVICE INFO & CALCS. UTILITY PROVIDER: PGE SHEET SIZE AHJ NAME: WASHINGTON COUNTY MAIN PANEL BRAND: THOMAS&HOMAS ANSI B MAIN SERVICE VOLTAGE: 240V MAIN SERVICE PANEL: 200A 11" X 17" MAIN CIRCUIT BREAKER RATING: 200A SHEET NUMBER 1 1 ELECTRICAL LINE DIAGRAM MAIN SERVICE LOCATION: NORTH PV-4 SCALE: NTS SERVICE FEED SOURCE: UNDERGROUND } PV-4 SOLAR MODULE SPECIFICATIONS Voltage rise in Q Cable from the Microinverters to the Junction Box For branch circuit #A of 10 IQ 8PLUS Micros, the voltage rise on the 240 VAC Q Cable is 0.46% Ct y MANUFACTURER/ MODEL REC400AA PURE BLACK For branch circuit #B of 11 IQ 8PLUS Micros, the voltage rise on the 240 VAC Q Cable is 0.55% W 3 VMP 42.1 V w D 2 IMP 9.51 A Voltage rise from the Junction Box to the IQ Combiner Box 0- _ ° N CI z c ~o N VOC 48.8 V VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft.) w Q W , J ISC 10.10 A = (1 .21 amp x 11 ) x (0.00129 QM) x (59 ft x 2) o Wi -- TEMP. COEFF. VOC -0.24%/°C = 13.31 amps x 0.00129 0/ft x 118 ft ♦ a Z a MODULE DIMENSION 71.7"(L) x 40.0"(W) = 2.02 volts %VRise = 2.02 volts _ 240 volts = 0.84% REVISIONS PANEL WATTAGE 400 W DESCRIPTION DATE REV The voltage rise from the Junction Box to the IQ Combiner Box is 0.84% REVISION 06'O9/2022 A INVERTER SPECIFICATION ENPHASE IQ8PLUS 72 2 US Voltage rise from the IQ Combiner Box to the Fused AC Disconnect MANUFACTURER / MODEL (240 V) VRise = (amps/inverter x number of inverters) x (resistance in 0/ft.) x (2-way wire length in ft.) MAX DC SHORT CIRCUIT CURRENT 15A = (1 .21 amp x21) x (0.000491 S2/ft) x (5 ft. x 2) CONTINOUS OUTPUT CURRENT 1.21A (240V) = 25.41 amps x 0.000491 QMx 10 ft. 0.12 volts Signature with Seal AMBIENT TEMPERATURE SPECS %VRise = 0.12 volts _ 240 volts = 0.05% RECORD LOW TEMP -8°C The voltage rise from the IQ Combiner Box to the Fused AC Disconnect is 0.05% AMBIENT TEMP (HIGH TEMP 2%) 32°C Voltage rise from the Fused AC Disconnect to the MSP CONDUIT HEIGHT 0.5" VRise = (amps/inverter x number of inverters) x (resistance in Q/ft.) x (2-way wire length in ft.) ROOF TOP TEMP 90°C = (1 .21 amp x21) x (0.000491 0/ft) x (5 ft. x 2) PROJECT NAME&ADDRESS CONDUCTOR TEMPERATURE RATE 54°C = 25.41 amps x 0.000491 0/ft x 10 ft. E MODULE TEMPERATURE COEFFICIENT OF VOC -0.24%/°C = 0.12 volts o %VRise = 0.12 volts - 240 volts = 0.05% ( PERCENT OF VALUES NUMBER OF CURRENT The voltage rise from the Fused AC Disconnect to the MSP is 0.05% 0 o N Lo E CARRYING CONDUCTORS IN EMT Total system voltage rise all wire sections I- W w O @ 0.80 4-6 0.55% + 0.84% + 0.05% + 0.05%= 1 .49% 0 z Q Et ^ u = W OM , 0.70 7-9 J ° C) iO O 0.50 10-20 in W Q ---= 0 cop zz I 2 W DATE:06/09/2022 SHEET NAME SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4A /t4$Te 22. on leis' WARNING-Electric Shock Hazard 7 .,. GV 9 RAPID SHUTDOWN SWITCH cr� No user serviceable parts inside NOMINAL OPERATING AC VOLTAGE' 240V � o Contact authorized service provider for assistance NOMINAL OPERATING AC FREQUENCY: 60HZ W a) w LABEL LOCATION: MAXIMUM AC POWER: 6.30KW FOR SOLAR PV SYSTEM W - o AC DISCONNECT MAXIMUM AC CURRENT: 31.76A - --- — .-_.w•,. +- MAXIMUM OVERCURRENT PROTECTIVE LABEL LOCATION: N (PER CODE:NEC690.13.G.3&NEC 690.13.G.4) AC DISCONNECT F O o N DEVICE FOR AC MODULE PROTECTION: 40A (PER CODE:OESC 690.56(C)(3) �*Z z w z — — [A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED w w Q v ` LABEL LOCATION: ON OR NO MORE THAN 1 M(3FT)FROM THE SWITCH.] ui w_1 m 2 WARNING:DUAL POWER SUPPLY, MAIN SERVICE PANEL 0::' SOURCES:UTILITY GRID AND PV SOLAR SECTION:NEC690.52 z a ELECTRIC SYSTEM" LO LABEL LOCATION: lirrWARNING UTILITY METER 8 THIS EQUIPMENT FED BY MULTIPLE REVISIONS (PER CODE:NEC 705.12(B)(3-4)AND 690.59) DESCRIPTION DATE REV SOURCES. TOTAL RATING OF ALL REVISION 06/09/2022 A OVERCURRENT DEVICES EXCLUDING MAIN 3 1 PHOTOVOLTAIC SYSTEM AC DISCONNECT SUPPLY OVERCURRENT DEVICE SHALL NOT RATED AC OUTPUT CURRENT 25.41 AMPS EXCEED AMPACITY OF BUSBAR. NC INAL OPERATING AC OLTAGE 240 VOLTS LABEL LOCATION: MAIN SERVICE PANEL LABEL LOCATION: AC DISCONNECT Signature with Seal (PER CODE:NEC 690.54) 4 ....- - WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE PROJECT NAME&ADDRESS LABEL LOCATION: MAIN SERVICE PANEL (PER CODE:NEC 705.12(6)(3)(2)) E [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] N— U X— — 1 CO FS 5 AWARNING oN TERMINALS ON THE LINE AND I— W W r O LOAD SIDES MAY BE ENERGIZED D U Gt O7 Cr) S IN THE OPEN POSITION O Z W W' V = W QO CO LABEL LOCATION: O i 0 COMBINER BOX,AC DISCONNECT&MAIN w SERVICE PANEL (PER CODE:NEC 690.13(B)) _ W M ~ O -C SOLAR PV SYSTEM EQUIPPED 0 WITH RAPID SHUTDOWN 2 i Q 6 TURN RAPID SHUTDOWN SWITCH TO THE w "OFF"POSITION TO so�nae�ecmic SHUT DOWN PV SYSTEM av vnNe�s AND REDUCE SHOCK HAZARDMill IN THE ARRAY DATE:06/09/2022 LABEL PER NEC 690 56(C)-PROVIDE AT SUB PANEL OR SHEET NAME SERVICE PANEL FOR RAPID SHUTDOWN COMPLIANT SYSTEM SHEET SIZE ADHESIVE FASTENED SIGNS: •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT ANSI B WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD 11" X 17" APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD i COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. SHEET NUMBER •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF RESISTANTPROPERLY [IFCDH 6RED.I VINYL] SIGNS SHALL BE WEATHER PV-5 �,2022—COM IX N 0 0 MI W N fr RECPRODUCT SPECIFICATIONS p- i I N _ o re � o 'r�x: :. SOLAR'S MOST TRUSTED SOLAR'S MOST TRUSTED Q.Z Z w z 2 N ,.� RCC Ilk � Can � µ .t W W J rn J O. ,. 1821.2.5[71.7x0.11 Z d �'!2811.1] _ 90I1,355] 46011s.11 CERTIFICATIONS I 5.- a d EC 61215.2016,IEC 61730 2016.UL 61730(Pending) + ;50140012004,1509001.2015,0HSAS 180011007,,1062941 l 't l MCI[43.3r �/p��,� � REVISIONS '� �CIL C E 1 i 1 DESCRIPTION DATE REV 6.030.2 REVISION 06/09/2022 A z 10.24±0.01] ;' WARRANTY 4k . ' a c Standard RECProTnmt ® %A InstalledbyanREC Certified No Yes Yes N o, o tt•oz Solar Profess -- fr7 a , S.[o43±0n11 System Size All s25kW 25-500kW g� Product'Warracty(yrs) 20 25 25 t i ? G R 20,5,0.5 1'-' Power lNarcarlYy(yrs) 25 25 25 I. foeto-azl M� 1200[47.21 Labor Warr ar,ty(yrs) 0 25 10 c� Powerir.Yearl 98% 98% 98% Signaturewith Seal I '� r` Annual Degradation 0.25% 0.25% 0,25% as[IS] 22.5[0.91 673 13[26.4s0 12l R Power in Year 25 92% 92% 92% r Measurements to mm kill t.130[i.21 Seewarrmtty documents far details Conditions apply GENERAL DATA MAXIMUM RATINGS 132 half-cut RECheteraju tancells StauMMC4pVKBT4f1C5T4,12AWG(4nmz) Operational temperature: -40..,+185°F(-40. +85°C} Cetitype: wth[eadfreegaplesstechndagy Connectors: nacmrdmcerlthlEC6�52 Maximum system g si voltage: I000V 6strngsof22cellsinseres IP68on!ywhenconnected PROJECT NAME&ADDRESS 0.13in(32mm)solarglasswith 12AWG(4mm5)PVwire,43+47in(1.1+12m) Maximum testlaad(frant): +7000Pa(1461bs(sgft)` d Glass' anti-reflection surface treatment Cable accordancewthEN50618 Maximum test load(rear) -4000Pa(83.5lbs/sgft) Backsheet. Highly resistant polymer(black) Dimensions: 71.7x40x12in(1821x1016x30mm) Maxseriesfuseratirg: 25A a E Max reverse current 25A ii Frame, Anodized atuninum(black) Weight 45 lbs(20.5 kg) Seeirstatlatianmaxatarrountnggist xnos 0 3-part,3bypassdiodes,IP67rated Designload=Testioad(]5[safeiyf�tor) L r V Junction box: Origin Made in Singapore I CO � naccordancewithlEC62790REC ALP oC® PURE ELECTRICAL DATA Product Code':RECxxxAA Pure Black TEMPERATURE RATINGS' V 0 C\I v P5 ;., _,„, .. .., ._ .. awerOutput-P.,n,(Ydp) 385 390 395 400 405 Nominal Module Operating 44°C(xZ°C) a F- w LLI r- Watt Class Sorting- 0/+5 0/.5 0/+5 0/+5 0/+5 TemperattrecoefficientofP,,t,,,,: -0.26%PC E D U C) CO BLACK ���I� o Nominal PowerVohage-VA,(Y) 4L2 d1.5 418 421 424 TemperattrecoeffcientofV 0.24%/`C O .., wQ F Nominal Power Current-1,,.,(A) 9.35 9.40 9A5 9.51 9.56 Temperattrecoefficient ofl,c. 0.D4%/'C a 0 L_ Open Circuit Voltage-V,(V) 48.5 48.6 48,7 48.8 48.9 The temperaturecoeffiuents stated are!i near vdues J CM o ct L0 0 PRODUCT SPECIFICATIOf�S ' ShortCrcuitCurer,t-I (A) 9.99 10.03 10.07 1010. 10.14 LOWLIGHTBEHAVIOUR < w CD < 0 E Power Density ft) 19,3 (9,6 19.8 201 20.3 I _ Z t :.' Panel Efficiency(%) 20,8 21,1 21,3 21,6 21,9 Typical low irradia nce perf ormance of module at STC: Fy U F- . . as - J Power Output-P,,,,,(WP) 293 297 301 305 309 I d kpr F Nominal Power Voltage-V,,pe(V) 38.8 39.1 39.4 39.7 40.0 l .. t. Q CC x Nominal Power Current-1,,w(A) 7.55 7.59 7,63 7.68 772 I A G Open Circuit Voltage-V,„(V) 45.7 45.8 45.9 460 46.1 t .. m •. s +m .ie 2 EXPERIENCE ShortCircuitCurrent-i (A) 8,07 810 8-13 8.16 8.19 Inadarce(W/ Vaiuesatstaitdardtestomdt4r15(STC:airy+sssNAlS.Irradancel0.75W/s9ft(tovY/ Ltefryeratrxe7Tf(25°Cltrasedmaproduaian DATE:06/09/2022 R spreadeilhatderaxreeur,,V.,,&t,;dweed3nonevattcHs .0.7xmoduleopctatngtenperature{NMOTatrna.:,,ve irraf�� 1 r t 1 P 860w ,tenpea5xe6 wMspeed3W15in anSdereaxlnaes n xpwcrdass(P.�atsTewa4UOwP SHEET NAME Founded in 1996.REC Group is an international pioneering solar energy �.y r EQUIPMENT 25 YEAR �{PROTR company dedicated to empowering consumers with clean,affordable iy SPECIFICATION WARRANTY salar power.As Solar's Most Trusted,REC is commItted to high quality, W innovation,and a low carbon footprint in the solar materials and solar wwwrecgrnup,cam SHEET SIZE 20.E FT' LEAD-FREE panels it manufactures.Headquartered in Norway with operational 0 '. headquarters insingapore.REC also has regional hubs inNorthAmerica, . '' ELIGIBLE ROHS COMPLIANT PERFORMANCE Europe,andAsia-Padfic. 4. ANSI B 11" X 17" SHEET NUMBER PV-6 /145T 2O22.-0711 se- fn 0 0 WI a, Tt 3 - o EN PHASE IQ8 and IQ8+ Microinverters a F �CC N a, o E F0 N INPUT DATA IDCI 108-60-2-US IDBP:US-72-2-US CL Z Z Lij~ ro N 0 Commonly used module pairings' w 235-350 235-440 -.� rui eUJJ- N. m it 0 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72ce11/144 half-cell ' a O Z a MPPT voltage range V 27-37 29-45 III le IF ro Operating range V 25-48 25-58 ro Min/max start voltage V 30/48 30/58 REVISIONS --' Max input DC voltage V 50 60 DESCRIPTION DATE REV Max DC current.[module Ise] A 15 REVISION 06/09/2022 A4 Overvoltage class DC port II DC port backfeed current mA 0 ,H>SE 108. 2 E los PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IAC1 108-6D-2-US 108PLUS-72.2-US , Mk ION Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Signature with Seal Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 I08 and IQ8+ Microinverters Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit' 16 13 Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Total harmonic distortion <5% defined microinverters with split-phase power conversion capability to convert DC Overvoltage class AC port III Easy to install PROJECT NAME&ADDRESS power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the • Lightweight and compact with AC port backfeed current mA 30 microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting 1.0 55nm technology with high speed digital logic and has super-fast response times • Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging E to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Peak efficiency % 97.5 97.6 O energy systems. • Faster installation with simple CEC weighted efficiency 'u 97 97 1 N— CO two-wire cabling Night-time power consumption mW 60 U Et co L�•) f73 oN 1 E {} hase MECHANICAL DATA W T h • • ._ High productivity and reliability �jJ V♦ ("Dr Ambient temperature range -40°C to+60°C(-40°F to+140°F) N '+ O • Produce power even when the _C year Im,I^� grid is down Relative humidity range 4%to 100%(condensing) W _ U DC Connector type MC4 0 w Q O M at.-+ • More than one million cumulative o O L PEnergy System, reliability hours of testing Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") _ 0 Part of the Enphase IQ8 Series IQ8 Series Microinverters redefine -I Cr) a Microinverters integrate with the Enphase IQ standards with more than one million Weight t.08 kg(2.38 Ibs) W v) Q Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, • Class II double-insulated Q W E App monitoring and analysis software. enabling an industry-leading limited warranty enclosure Cooling Natural convection-no fans N (0 0 O _C of up to 25 years. I LL M • Optimized for the latest high- Approved for wet locations Yes 0 Z powered PV modules Acoustic noise at 1 m <60 dBA I J 111/ 0Pollution degree PD3 Q Microgrid-forming Enclosure Class II double-insulated,corrosion resistant polymeric enclosure w CERTIFIED • Complies with the latest Environ.category/UV exposure rating NEMA Type 6/outdoor SArEi\' advanced grid support COMPLIANCE Connect PV modules quickly and easily to 108 Series Microinverters are UL Listed as • Remote automatic updates for CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 DATE:06/09/2022 IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 20t4,NEC 2017,and NEC 2020 section SHEET NAME connectors. according to manufacturer's instructions. • Configurable to support a wide 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to EQUIPMENT range of grid profiles manufacturer's instructions. 0 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, • Meets CA Rule 21(UL 1741-SA) (1)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/ SPECIFICATION and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage SHEET SIZE range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to IQ8SP-DS-0002-01-EN-US-2021-10-19 local requirements to define the number of microinverters per branch in your area. I08SP-DS-0002-0t-EN-US-2021-10-19 ANSI B 11" X 17" SHEET NUMBER PV-7 /t14. 7-2022.-(,1c 5 - _ . En phase IQ Combiner 4/4C .- ")'8 MODEL NUMBER ::::at.a.:;itet V 1 .______________ ____ i_ co Eriphase Networking .3, D.,,,,- 4.104-10411404! *" -..--oirwr A web Estabusse KlAtteswyortniedsiouttiteseofor tosowsmresenue goes MY producconnstainne(Afar 0 re 0 ' &' * Z Ci e ....:1*-014.)end coneurupbse regenarona(4-2.5%,1.Incauldess g sewer sole shield torrtartob feria Aertery swam tied z t44.WORT ,tertrte441-1'.amiss&elect beat lu Cgrobrrigr AC I A-1Q-AM1-2-41Z-ACI 10 Combos/AL sash Enplane<I ammo).printed areas board for r4tagra1ed man ue grade t-V;nonunion mists; 1 _,1111 LI L>j 71 4.. aoccesroneo ricrascsyg f+.2.5%)roclunes Lootosse Moink Cannot...col...tar modern -M- - . 0 W - tc/LLMCeJL-M-M1-116-9P-Oh'f,a tiog-gria-play inaustrus-grade eel modern for s*whyros uo so AC rocsairogreire tetrad:OW*In wg LC.t.enxids,Metuto,Noires loco,two bee L":.Weal Islands,whys item e adequate cellular zeroes Enphase The E;;otia.se 10 Cornbinei 4!4( with Enprase ACCESSORIES AND REPLACEMENT PARTS th:notmlaffinClux:C1730rdeflirnsep":376%*ir)lis"Wiluld 1r'nurtmtj l'. liatta7 au.lij Sigweirr CzMullt"II'4411gct him' *0 co IQ Gateway and integrated LTE-MI cell ...._ „ IQ Combiner 4/4C modem(included only with 10 Combiner 4C) Engamble C.Mtiminicitiara Sit COMA*5-01a-LMOOLMI-tri-011 ,inetudes COAAMS-004-41*401d CELLMODEUVI-Oti-SP*65 with bomaeloont date;San cot Lneembiegrest REVISIONS DESCRIPTION DATE REV C'ELLAMEA4-111-414.-SPCIA -CI breed LILA*t mauls'.oaten.resth Sias Aprin date stew X-10-AM1-240-4 consolidates interoonnectior;equipment calmboo.444n4w-kr-as -4a based LTE4ii 6 aelissier modern web Slaw Ate dant easy REVISION 06/09/2022 A Lincue1 Ate alum Simeon*Cesar bi210.E4://16 90=6,SP23O,814:AU la kVA,and leiZolarcurr breakers X-IQ-AM1-240-4C into a singe entiosure and streamlines IQ Abhtlart-O-2ALle bircien gig likgr,2 sok.Ws*Eyol 11,42 I C BR**-15A-17.--14.9e Cacin arsalw,:a oda,lbA,Ulla%IR:I 5 M IC roinverters and storage installation 5 by EIRILlOA-Vo-24,IIV escort breaker 2 otsIg„:ILIA Edson AR2ZLI Altrol SA-2P-Z4LIV-t* Cm,*totem'Zook.1 U4,;JIM/01115fi WO",hold dose/01 Lipson providing a consistent, pre-wired solution for 91,01.-110A-2 4-2AtIM-9 Garter harriesr,Z ook=A ['Yon PRIZIIS sten roll doer*••sesson . EPLC-01 Ames lass owner( , roar bodge gait)acantri*-WM ostr residential applications. it offers up to four $ xA-silL44;e1.4ift...t-LS Replacement solar Yield for 6.9 Loonlone.4'4-1: f• -7., 2-pole npi ircuits arid Eaton BR series AA-PLUG-120.1 Aoccesosy/144414M=191 far Power Ling Cynic in 1;.}C-0.041.stIMIT Ott Acquired for CPU: 1 Signature with Seal bu5ba-55E ff..-7..'1.:,' X.A4.filY-PMA1 byphsesownt 6 Astsway orrsted drost board 6PC9'.far COmillre,4.4.1C X-4044440-12514 IWideforraeld for Eaton Yew*issiker sill weense ELECTRICAL SPECIFICATIONS ,• ',C1 Smart Petted Cattiest/se diay f,,-*...!-"-; -,4*-•' • includes IQ Gateway for communication and control System Worse *'.. Ab VAC,b0*to ',..4.:",: • Includes Enphase Mobile Connect cellular modem Wan liA terves bosber ralam 125 A (OEWOODEM-M1-06-SP-05),included only with IG ma).nomnunus ciarrin!:ritng Si A PROJECT NAME&ADDRESS Combiner AC Misterasesoustue0Aggiltrasna 0.yedtssePienvlesod 64 A . :ncLades solar shield to match Enphese lQ Battery Mae fussiorrouo rating,;-a---1:.,L,1 9t:A aesteetics and deflect heat aninin amass Oman vinafor storaori Lip Whew 2,01,F-0314 ea**nu tat:bibelot!asegrettor LIXItioreelarre wary trod StraLeity* E ,, . Flexible networking supports Sfiri-Ff Max fetal traincn drew gratorir rating icirgat) SCA ef tt.stramactl eenergLICO 0 gar.with..4:1 Azieway brgeker included 0 Ethernet or cellular Onialuiroan owisetrserf MO Asistatcrie risweretaAtst wed tenet es ICrasissetO •-••• U 6 •*- * Optional AC receptacle available fur PLC bridge tor ....iti Conatargbion rfarlitarrng 4.;I 0:1-21:111-SPiJi} A pair of=OA oohs core evrrient irsnrylorrners I CO ro Et • Provides production metering and consumption C.) ---, CO Lr) MECHANICAL DATA I--I CV I monitoring U) ,.. 1 i 1 C\I a) ta0 ______________ _ ___ _ _ _____ ... -Dimaruarins(Wstniti) atsiliss16.11 cot flli.-rr s lArs Abr.*44.-Otrarr-Frii/A-7157ff*aro iiim -moan bonnie.- I— LIJ a WeigSt Y.$koritL5 btu 1X01: °.) CO7d 11..- Simple Ambles!34111Verlit4r4"MP -.40*A to*WC(-**tr to 11 0 Z r2 5.F) -C -cil "..-"'• (-) • Centered mounting brackets sup at port single coiiiirs Natorei CrOeCb:0n,Ow neon Week W --1` 0 Cf) (1) , atird mountIng EricketuntanytranmantaitAbiN Ouridocs,NATL-Yettifterl,fetMet type th.,..potecerhonate conanuctinn —I — r ri- a 1.0 0 • Supports bottom,back and side conduit entry W U) Ct ..0 row' or .29 A so 50 A breaker yawls 14 to 4 kWh cooper conaLclors • Up to four 2-pole branch circuits for 240 VAC -SC A Itsgeber branon rroot it to'Id AWL.copper norsructore < 1; o )647.44M I-240i:: E . ._. , plug in breakers not included) .lean lug mare:wed certot 1 n to 2.:1 AwS cooper conductors I Ct (0 ° -. -C i* -'' • itrat to M CY) I-- L. . . --1 • R DA total PV or storage branch circuits Mir end around:ta t comer conductors (..) - , Ahrays folks*local cods gebuirsinents for conductor siOno i —I ToZ fir . IODrottnik,560 faro 0_ < Reliable ItTrEDNET CONNECTION OPTIONS k..d.pordw... ' Durable NRTL-certified(NBA type 3R enclosure rwa-tlar CP I IbeitiEekle-tOn-V*-AM CEI-LMOOLM-411-C*541-05 14G bawd L t L-m'-*linty foadorn1 Mom my at'Cronus°. • Frre-year limited warranty Mobile Crawled stekiworeacire sr rgestred ts ail Ingernbit rotailisone Two years labor reimbursement program coverage tiessnr• r...`ctor's! rz..tt.est5E far CY LIKITP Isharnet tette toot insiudedi included for both the IQ Combiner Sfars COMPLIANCE DATE:06/09/2022 • ill listed ci-,,:is.i.-,,.,. ., "rrabitarir ILA/41,CA-f4fCSA=22 tes.10/1 AY Cf.&Pile 1ints ain SHEET NAME Production touts* .0:ANM C12.10 amiiniay class tStisYrooduidicad EQUIPMENT toneurntsbOnfrrOgigglq acouswar dass 2-5 U....rit tar-1 rtAfit'JLA 11.'2 No OLI , SPECIFICATION_ . ...._..... (DI 1 :..,...,-,,M1-2.40-4 SHEET SIZE I LISTED , ENPHASE ENPflASE rncire-about Enoinase offeringa,visit enohasexont To learn=re about Enphase offerings,visit tfighase.sam ,...,,,o. ANSI B ....,,:f1r.,...4-.Ei-,,MI rtlat nr.sentt-i clitkar.M.-ifx-9-• -...wo tr.-*-.•:':-•••-rove 4.4.," :1,7,,rfIrmi ribrim art tr-alen,3 I-:,f rrantrot tr Nagy.,re.Liar cuown to charge 'IA,:".•--XI'4 1 1" X 17" SHEET NUMBER PV-7A Vim ,,, o o_ W °. E y F-o DESCRIPTION: 1 DRAWN BY: DESCRIPTION: DRAWN BY: = Li Po N Snar3N ck- Sn pH Eck- o` _ co gl SNAPNRACK, ULTRA RAIL COMP KIT mwatkins SNAPNRACK, ULTRA RAIL COMP KIT mwatkins 11„Z z W 0- 09 " REVISION: REVISION: 3 w 4 in J PART NUMBER(S): PART NUMBER(S): p 2- 583 MARKET STREET,281H FLOOR•BAN FRAN08300.CA 94105 USA g 595MMIET STREET.2YTH FLOOR•SUN FRANGISCO.CA 54505 USA a d PHONE(413)58089110•FAX(415)580-0802 V PHONE(415)580-5900•FAX(415)5804902 Z SEE BELOW SEE BELOW " >HE aswuwrwr.w rme auwwo m ewnoeNnuArovsovAtum.A4Y wvasamn wrens pvwsw wralceHluuovwaRtrAxr.Aur aeewoenox.MIMICs.cw T 'SMS U.1...owir..ant� axvAowcmx.ownnsua.a.gee rnereorls awxaTeowmlart ens r WRPtB1CCN6CM OF3lMlUN80ViN LLG WtTptpNBEN!K6IMNNS,d11H NL. UMBRELLA L FOOT PROPERTIES REVISIONS SKU DESCRIPTION DESCRIPTION DATE REV 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER REVISION 06/09/2022 A 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK ` (.2 !i' 1.37 I ;;_,.,,,,,,,,,„ , It ® .38 ..~► .30 ti , 1.00 4 '� SLOT v� ' © �� Signature with Seal ® "'� ✓ � 1.50 0 ,.® b � 3.25 w 2.78 � } 1.78 1.62 0 Iti 1.80� -.-1.50-4- PROJECT NAME&ADDRESS 2 COMP FLASHING PROPERTIES 11) SKU DESCRIPTION E kriii \ 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM U 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM _ � E ..... "� '�- � ' ' / - - - I vv) oci) a 0 U rn c� c ) I 0 Zw � �� L 30 01.00 O W < O o 6.75 � pIIl�J�QInS tr M\ J — U) LI e, O r �food _ LU U) t `°° I iQ LiJ (D Q ® I D (O S2 I U 2i— j 11.75 s I 0_ Q PARTS LIST ITEM QTY PART NUMBER DESCRIPTION e o 105° 4.20 LLI 1 1 242-92266 SNAPNRACK, UMBRELLA LAG,TYPE 3, 4IN, SS 2 1 242-01219, 242-01220 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER/ BLACK < ----1----- 3 1 232-01375, 232-01376 SNAPNRACK,COMP FLASHING, 9IN X 12IN, SILVER/ BLACK ALUM DATE:06/09/2022 1 SHEET NAME MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER I 0.35 DESIGN LOAD (LBS): 802 UP, 1333 DOWN, 356 SIDE 3.25 ' EQUIPMENT I ULTIMATE LOAD (LBS): 2005 UP,4000 DOWN, 1070 SIDE SPECIFICATION TORQUE SPECIFICATION: 12 LB-FT SHEET SIZE CERTIFICATION: UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 1 8.75 .45—s- 1-0-- ANSI B WEIGHT(LBS): 0.80 ALL DIMENSIONS IN INCHES 11" X 17" SHEET NUMBER PV-8 f DESCRIPTION: DRAWN BY: y o Sn ' Iroc SNAPNRACK, UR-40 RAIL mwatkins .! a N o o REVISION: : 3 ~1) 1- o N W PART NUMBER(S): o c o Qu 595 MARKET STREET.29TM FLOOR•SAN FRANCISCO.CA 94105 USA Z Z w N PHONE(415)5904900•FAX 1415)590-9902 NE 232-02449, 232-02450, 232-02451 W W 1 TIE INFORIAATIDNNT1980R.CRl IS WNFlDENTIAI AND PROPRETARY.ANY -J lU a J RE%tOpJC110N,DIITTCR ONSENTOFSIREOF RPRON®REDNTMOUT THE 7 W F Q MRNl13l CONSENT OF SUNRVN SOUlN LLC. 0 d �0 za u, UR-40 RAIL REVISIONS DESCRIPTION DATE REV PROPERTIES REVISION 06/09/2022 A SKU FINISH 232-0202449 MILL 232-02450 CLEAR 232-02451 BLACK ', Signature with Seal ,--, 00.00 y e�. PROJECT NAME&ADDRESS C.---j4 750 1.500 1 1 O U = 00 f0 U o12 � � E 832 (1)(...)I W'''R\ T.'" = w oen GI O z W o C = W Q O co--, � SECTION PROPERTIES a 0- �O O 1.624 WCO Ct "t A 0.357 in2 ' Q W ( Q E Ixx 0.125 in4 CENTROID = M O U Iyy 0.132 in4 = Sx (TOP) 0.150 in3 792 0_ Q Sx (BOT) 0.158 in3 Sy (LEFT) 0.175 in3 W Sy (RIGHT) 0.175 in3 I i DATE:06/09/2022 SHEET NAME ALL DIMENSIONS IN INCHES EQUIPMENT MATERIALS: 6000 SERIES ALUMINUM OPTIONS: SPECIFICATION DESIGN LOAD (LBS): N/A CLEAR/ BLACK ANODIZED SHEET SIZE ULTIMATE LOAD (LBS): N/A MILL FINISH ANSI B TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 144 11" X 17" CERTIFICATION: UL 2703, FILE E359313 BOXES OF 8 SHEET NUMBER WEIGHT (LBS): 5.85 - - PV-9