Loading...
Plans (2) .. PHOTOVOLTAIC ELEMENTAL 8ENERGY ROOF MOUNT SYSTEM RECEIVED 1339SEELE 30 MODULES-ROOF MOUNTED - 10.95 kWDC, 8.70 kWAC PORTLANDOR97214 NOV 1 9 2021 Phone-(541)316-5786 Contractor#OR CCB#:195141 14885 SW 100TH AVE, TIGARD, OR 97224 USA CITY OF TIGARD REVISIONS 3UILDING DIVISION DESCRIPTION DATE PROJECT INFORMATION: SYSTEM SUMMARY: GOVERNING CODES: OWNER: WEBER, MARILYNN SYSTEM SIZE : 10.95 KWDC 2020 NATIONAL ELECTRICAL CODE (NEC) ADDRESS: 14885 SW 100TH AVE,TIGARD, OR 97224 SYSTEM SIZE : 8.70 KWAC 2019 OREGON FIRE CODE (OFC) COUNTY: WASHINGTON COUNTY (N)30-REC ALPHA SOLAR REC365AA(365W)MODULES 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) APN: 2S1110602300 (N) 30-ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS COORDINATES: 45.41234,-122.78058 (E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER, PGE ELECTRICAL CONTRACTOR CUST. PHONE: N/A (N)60A FUSED AC DISCONNECT BUILDING DATA: SINGLE FAMILY RESIDENTIAL (N)60A UTILITY REQUIRED NON-FUSED AC DISCONNECT/RSID WITHIN 10' FROM UTILITY METER APPLICABLE CODES: 2021 OESC&2019 OSSC LIABILITY OFFICE COPY Approved plans FINANCING: N/A The City of Tigard and its CLIMATE DATA SOURCE: AURORA STATE e to ees shall not be DESIGN CRITERIA: shall be on job site. p y WIND SPEED:98 MPH (ASCE 7-16) CITE OF TIGARtt responsible for diSCrepanClesRisK CATEGORY: II REVILNN'LD FOR CODE_? COMPLIANCE why may 'iooear herein. WIND EXPOSURE CATEGORY: B / SHEET INDEX GENERAL NOTES: ROOF SNOW LOAD:25 Approved: [ j PV-0 COVER SHEET ROOF TYPE:ASPHALT SHINGLE 1 PV-1 OVERALL SITE PLAN 1. PV SYSTEMS AND SUPPORTING STRUCTURE SHALL COMPLY NUMBER OF LAYERS:01 OTC: Q PV-2 ROOF PLAN WITH MODULES WITH REQUIREMENTS OF 2021 OESC &2019 OSSC. ROOF FRAME: PRE-ENGINEERED TRUSSES @ 24N.Icnit #: �j/ J/I -- co OSL v PV-3 STRING LAYOUT PROJECT NAME 2. 3111.3.2 PV RACKING AND ATTACHMENTS SHALL BE UL 1703 STORY: ONE PV 4 FRAMING PLAN CERTIFIED. Aciclress. �y$Qrj �(x7�'L f PV-4.1 ATTACHMENT DETAIL& 3. 3111.3.4-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION Suite #: • CLAMPING METHOD W THAT IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY ^ ' PV 5 ELECTRICAL LINE DIAGRAM 0 1505.1. By: Date: I� h PV 6 WARNING LABELS Z REQUIRED BY OSSC SECTIONW 4. 3111.4.3-3111.4.7-PV LAYOUT SHALL NOT RESTRICT EGRESS, LIGHT VENTILATION, OR ROOF DRAINAGE REQUIREMENTS. 5. 3111.4.8.1 -GENERAL PATHWAY REQUIREMENTS: 0 • 36"WIDE PATHWAY SHALL NOT BE REQUIRED ON IJJ Q N CV N CO W STRUCTURES WITH A PV ARRAY AREA OF 1,000 SF OR LESS •' - " INSTALLED ON A ROOF WITH A SLOPE THAT EXCEEDS 2:12 AND Z m WITH AN INTERSECTING ADJACENT ROOF AND WHERE NO SECTION IS LARGER THAN 150 FEET MEASURED IN LENGTH OR PROJECT SITE : AR " `� LOCATIONS O WIDTH. ' J 0 - 4:k 1 • WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN N— >_ PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A N 7-1 MINIMUM OF 12"UNOBSTRUCTED PATHWAY SHALL BE Q MAINTAINED ALONG EACH SIDE OF ANY HORIZONTAL RIDGE.• s _li "''�# �_ c0 0 Z D WHERE THE SOLAR ARRAY EXCEEDS 25%AS MEASURED IN ;- PLAN VIEW OF TOTAL ROOF AREA OF THE STRUCTURE,A tv` � ,; � ,N) Q MINIMUM OF ONE 36"UNOBSTRUCTED PATHWAY SHALL BE PROVIDED IN ADDITION TO A MINIMUM 12"UNOBSTRUCTED 4 m ALONG EA. SIDE OF ANY HORIZONTAL RIDGE. 6. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD � � wt CONSTRUCTION WITH PRE-ENGINEERED TRUSSES @ 24"O.C. �' REFER TO ALLOWABLE SPAN REQUIREMENTS IN TABLE 305.4.1. tgad ` t t � � 7. 3111.4.8.5.1 -DISCONNECTS, J-BOXES, COMBINER BOXES OR � • _ PROJECT VALIDITY OF PERMIT GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAY � � �� OR CUTOUT. THE ISSUANCE OF A PERMIT 8. 3111.5.3.1 -TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 4.5 BASED ON CONSTRUCTION " E. ': = SHEET NAME PSF. PV MODULES AND RACKING SHALL BE DIRECTLY DOCUMENTS AND OTHER vi t°, - ATTACHED TO ROOF FRAMING AS SHOWN IN PV 2. COVER SHEET ATTACHMENT SPACING WILL BE 48"O.C. MAX,AND WHEN DATA SHAI-1 N{ Z VE ?N.ATTACHMENT LOCATED WITHIN 3'OF ROOF EDGE, HIP, EAVE, THE CODE OFFIP� RIDGE SHALL BE 24"O.C. MAX. RE(�UIRING THE CORR�CrTlC7N 9. 3111.5.4-MAX MODULE HEIGHT< 12" OFF ROOF SURFACE. OF ERRORS.�RS(i 105'4 xx. SHEET SIZE 1Q* .r ANSI B COVER SHEETNTS. VICINITY MAP ^ AERIAL VIEW ^ SHEET NUMBER OJ SCALE: NTS SCALE:NTS PV-0 SCALE: ,. EE) ELEMENTAL PROJECT DESCRIPTION: ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ENERGY ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 1339SE8THAVE, 30 REC ALPHA SOLAR REC365AA(365W) MODULES ROOF ARRAYT ROOF TILT AZIMUTH pORTLAND, 97214 30 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS #1 20°L20° 91° Phone L(ND OR97214 786 Contractor#OR CCB#:195141 #2 20° 20° 271° 8REVISIONS SYSTEM SIZE: KWDC (E) FENCE .70 70 KWAC DESCRIPTION DATE NOTE: "CHECK WITH CITY/COUNTY OR LAND SURVEYOR FOR ACCURATE PROPERTY LOCATION. —148.00' — PROPERTY LINE — — — — — — — NOTE: "ARRAY TILT FOLLOWS ROOF STRUCTURE. — — —� — Z , `o J 4 c° 90'-5' › ELECTRICAL CONTRACTOR C I OII ° rX Ia E(POND) ° I I PROJECT NAME ti U B , Z in CVI� 0 SUNEYE LOCATION ❑ (n W O I 0 SUNEYE LOCATION o L1.I Q N N W 1 (i ❑ I I� = O m 0_ ❑ I Z 1 ❑ 0 o O U i 0 —IN- O u 0 Q CO CC N ROOF#1 1 I in Q (16) REC ALPHA SOLAR REC365AA ' (N)60A FUSED AC DISCONNECT (INTERIOR) I A o0 C� z D (365W) MODULES I — d' Q z 0 m w 3, 8" 44 m O ---I BMW 1 ROOF#1 ROOF#2 EXISTING TILT-20° ' TILT-20° cn AZIM.-91° DRIVEWAY PROJECT 62 AZIM. 271° (O �Cb < N/A _ 171 SHEET NAME — - - PROPERTY LINE —133.72' OVERALL SITE PLAN ROOF#2 1(.-Ar (14) REC ALPHA SOLAR REC365AA SHEET SIZE (365W) MODULES ANSI B (N) ENPHASE COMBINER PANEL(EXTERIOR) (E)200A MAIN SERVICE PANEL WITH COVERALL SITE PLAN (N)60A UTILITY REQUIRED NON FUSED AC (E)200A MAIN BREAKER (INTERIOR) SHEET NUMBER 1 DISCONNECT/RSID WITHIN 10' FROM UTILITY (E)UTILITY METER (EXTERIOR) PV-1 SCALE: 1/16"= 1'-0" METER(EXTERIOR) ,N=.1.1., BILL OF MATERIALS ELEMENTA MODULE TYPE, DIMENSIONS & WEIGHT EQUIPMENT QTY DESCRIPTION ENERG' NUMBER OF MODULES=30 MODULES \ 1339RTN ,ORH 97214 MODULE TYPE=REC ALPHA SOLAR REC365AA(365W)MODULES SOLAR PV MODULE 30 REC ALPHA SOLAR REC365AA(365W)MODULES Phone SE 8T AV , MODULE WEIGHT=43 LBS/19.5 KG. INVERTER 30 ENPHASE IQ7PLUS 72-2-US MICRO-INVERTERS Contractor*5OR 4 )316- 86141 MODULE HTOFDIMENSIONS= =2.28 PSF= 18.83 SF —I- COMBINER PANEL 1 ENPHASE COMBINER PANEL REVISIONS UNIT WEIGHT OF ARRAY=2.28 60A UTILITY REQUIRED NON-FUSED AC DESCRIPTION DATE DISCONNECT 1 DISCONNECT/RSID WITHIN 10'FROM UTILITY GENERAL NOTES: ° METER 1. CONDUIT IS DIAGRAMMATIC.FINAL ROUTING TO DISCONNECT 1 FUSED AC DISCNONNECT BE DETERMINED BY INSTALLER. LARGE POLARIS 2 LARGE POLARIS BLOCK FOR SSC - ROOF DESCRIPTION FUSE 2 50A FUSES ROOF TYPE ASPHALT SHINGLE JUNCTION BOX 2 Q-BOX PRE-ENGINEEREDA Q DROPS 30 Q CABLE DROPS ELECTRICAL CONTRACTOR ROOF ROOF TILT AZIMUTH TRUSSES SPACING TERMINATOR 3 ENPHASE Q CABLE TERMINATOR CAPS #1 20° 91° 24"O.C. MICROBOLTS 30 IRONRIDGE MICROBOLTS(BHW-MI-01-A1) 1 #2 20° 271° 24"O.C. RAIL 15 IRONRIDGE XR100 RACKING-168"SECTION RAIL SPLICE 8 SPLICE KIT(XR-100-SPLC-M1) MID CLAMP 57 MID CLAMPS(UFO-CL-01-A1) (E)ASPHALT SHINGLE ROOF (TYP.) o END CLAMP 21 END CLAMPS(UFO-STP-32MM-M1) n- ATTACHMENT 84 IRONRIDGE FLASHFOOT 2 ATTACHMENTS (E) PRE-ENGINEERED TRUSSES @ 24"O.C. GROUNDING LUG 4 IRONRIDGE GROUNDING LUG(XR-LUG-03-A1) GUARD 1 CRITTER GUARD 1)__. PROJECT NAME E+ ti.14 W 0 0 r Z L1JTZI W ROOF#1 \ W > ---�--- U 1 Rl (16) REC ALPHA SOLAR REC365AA Z W 0 (365W)MODULES ROOF#1 1 W W Q N N w TILT-20° o---� — 1 ui CC O f-I D AZIM.-91° ---- W _ O' m o 0 (4 W "I ‘i" 1 -n f—— - ? T `\ 0 I— t - �_ oL FIRE PATHWAY Lf) Q It 1— i- +-- r-- , U ----4----� / _ co, 14 H. Z rn , I % N / m a fi i - �- -�; W ' i + __ -_ _ LEGEND (84) IRONRIDGE FLASHF OOT 2 -- — '- - -- (N)60A FUSED AC DISCONNECT(INTERIOR) UM UTILITY METER ATTACHMENTS SPACING $ I ` (E)200A MAIN SERVICE PANEL WITH 24 &48" O.C. \\�— ——- 1 ,1 IACDI FUSED AC DISCONNECT PROJECT (E)200A MAIN BREAKER(INTERIOR) _ 200A MAIN SERVICE PANEL ` —t- . 1 I ` (E)UTILITY METER(EXTERIOR) MSP WITH 200E MAIN BREAKER N/A (N) IRONRIDGE XR 100 RAIL __� i• r> � \ CB ENPHASE COMBINER PANEL SHEET NAME °BI ° UM ARRAY AREA & ROOF AREA OF MAIN HOUSE 1'k 11'-5" / / 11'-5" 1-0 , ' 60A UTILITY REQUIRED ROOF PLAN WITH 1'-0" 1'-0" CALC'S UD NON-FUSED AC DISCONNECT/RSID 4 AREA OF NEW AREA OF ROOF(PLAN TOTAL ROOF AREA WITHIN 10'FROM UTILITY METER MODULES ROOF#2 -- ROOF#2 ARRAY(Sq.Ft.) VIEW)(Sq. Ft.) COVERED BY ARRAY (14) REC ALPHA SOLAR REC365AA TILT-20° 264 3263 8% QB QeQx AZIM.-271° SHEET SIZE (365W) MODULES 8% ROOF AREA(ARRAY<25%OF ROOF AREA) IYY CHIMNEY ANSI B (N) ENPHASE COMBINER PANEL ARRAY AREA & ROOF AREA OF CARPORT CALC'S �J\ (EXTERIOR) AREA OF NEW AREA OF ROOF(PLAN TOTAL ROOF AREA 0 PIPE VENT ROOF PLAN WITH MODULES (N)60A UTILITY REQUIRED NON-FUSED AC ARRAY(Sq.Ft.) VIEW)(Sq.Ft.) COVERED BY ARRAY% ATTIC VENT SHEET NUMBER DISCONNECT/RSID WITHIN 10'FROM 301 748 40% PV-2 1 SCALE: 3/32" _ �-0" UTILITY METER(EXTERIOR) 40% ROOF AREA(ARRAY>25%OF ROOF AREA) CONDUIT RUN .�' (30) REC ALPHA SOLAR REC365AA MODULE ,r 67.8" l• ELEMENTALENERGY (30) ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS 1RLAND,OH AVE, PORTLAND,OR 97214 Phone-(541)316-5786 (03) BRANCHES OF 10 MODULES CONNECTED IN SERIES PER BRANCH Contractor#OR CCB#:195141 REVISIONS PHOTOVOLTAIC MODULES — DESCRIPTION DATE REC ALPHA SOLAR REC365AA(365W) MODULES 0 0 FIRE PATHWAY ° ELECTRICAL CONTRACTOR o \ 0 PROJECT NAME [Li \ (z U LI W lll 0Z z w 0 \\ > M (5 =LL3 W Q N O CZ I— i NN LIJ (16) REC ALPHA SOLAREC365AA I N- 0 0 C.) (365W) MODULES IL OI- z I-- d) CO 0 Q \ O >_ CD O CD o — JCC � o \k'\\\**\k4 ® \ eZ I i ,• \ o m \ • • � \ w I I -A � PROJECT ■ a I I \ i I al • \ N/A i � I \ SHEET NAME i I M BRANCH LAYOUT \ I! SHEET SIZE ANSI (N)Q BOX(TYP.) (30) ENPHASE IQ7PLUS 72 2 US ROOF#2 SHEET NUMBER LAYOUTMICRO-INVERTERS (14) REC ALPHA SOLAR REC365AA PV-3 c1 )BRANCH /,,r, (365W) MODULES SCALE: 3/32" = 1-0" _i.r. ELEMENTAL (E)PRE-ENGINEERED ENERGY SOLAR MODULE TRUSSES @ 24"O.C. 1339 SE 8TH AVE, RAKE RAKE PORTLAND,OR 97214 Phone-(541)316-5786 Contractor#OR CCB#:195141 REVISIONS w\ 141111 -77All - DESCRIPTION DATE ——Lf /< \ '.77 -- UJ‘ I !'� I EAVE -I ELECTRICAL CONTRACTOR I O III m ►! - a_ - - m o RIDGE m J lL \ 'IL (\� PROJECT NAME 7:1EXTERIOR LOAD EAVE BEARING WALL LIJ V U o \e�y 3SECTION DETAIL 1.11 Z SCALE: 3/16" = 1'-0" 0 - 00 W Et Q N CV C\I CO W -- RIDGE Z _. rn m 0- __ (E)PRE-ENGINEERED SOLAR MODULE Z O c O -0-- _ -� L� TRUSSES @ 24"O.C. J Co Q `C RAKE '-ii RAKE --� -; F Q -- �! 2 con U Z F- EAVE — PL'!IlI�:li MIR ifk oWNW 1 INENAI 11011111111 VP CO mi > glow -mi numi CO < I o co PROJECT Ali 11 iolimic 1 w N/A r wmeni Amo: SHEET NAME mu EXTERIOR LOAD BEARING WALL FRAMING PLAN DETAIL �1 RAKE \ \ \ \ RAKE RAKE RAKE SHEET SIZE ANSI B A FRAMING PLAN j\i, c SECTION DETAIL SHEET NUMBER / PV-4 SCALE: 3/32" = 1'-0" PV-4 SCALE: 3/16" = 1'-0" PV-4 , lee ELEMENTAL 1339 SE 8TH AVE, PORTLAND,OR 97214 Phone-(541)318-5786 Contractor#OR CCB#:195141 ENLARGED VIEW REVISIONS � DESCRIPTION DATE PV MODULE #,,.' �/ �/ ELECTRICAL CONTRACTOR AGO G./ 2 <12"ABOVE ROOF �ckk\--S NG\ �- - (E)ASPHALT SHINGLE ROOF 1 4. fio0'. p' Fig 23:REC Alpha Series MLPE device installation zones Fig.24:REC Alpha 72 Series MLPE device installation zones . olozemmp-oA mi Installation of MLPE device in the green zone is permitted. ill Installation of MLPE device in the red zone is not permitted. It y d t o.osmmlo-<om a 'gym PROJECT NAME r. 111 I C s a . V Z T ATTACHMENT DETAIL a w 3 0 SCALE: NTS - -_ CD o E_ w Q N CO W PV MODULE 1 CC D Z 1- CD a_ END/MID CLAMP dfr Z ocL U J IRONRIDGE XR-100 RAIL i s IRONRIDGE FLASHFOOT 2 ;' I Q ATTACHMENT a _ CO ' ' IY Mt H Q ®• Iu svr-olmmezol-a W ;% Iw.py-ol ww5wto W f i•I 11111�� PROJECT ilk N/A ALUMN. "L" BRACKET SHEET NAME W/3/8 SS BOLT & NUT (E)PRE-ENGINEERED TRUSSES ATTACHMENT l@ 24"o.C. DETAIL & CLAMPING le METHOD (E) ASPHALT SHINGLE ROOF SHEET SIZE dillgO ANSI B 5/16"x3.5"ASS LAG BOLT WITH CLAMPING METHOD SHEET NUMBER ENLARGED VIEW MIN 2-1/2 THREAD EMBEDMENT, PV-4.1 SEALED PENETRATION SCALE: NTS. 2 SCALE: NTS CONDUCTOR SCHEDULE AND CALCULATIONS ee ELEMENTALENERGY TAG LOCATION DESCRIPTION EQUIPMENT #OF BRANCH CURRENT(A) STC #PARALLEL #C.CARRYING WIRE WIRE COND. COND. AMBIENT MULTI DEBATED 1-WAY VD OCPD NEUTRAL GROUND CONDUIT CONDUIT L(FT.) % RATING SIZE SIZE TYPE SIZE 1339 SE STH AVE, MAX.MOD.IN INVERTER OUTPUT 690.8(A)(1) VOLTAGE(V) RUNS CONDUCTORS SIZE TYPE MATERIAL RATING(A) TEMP #COND. (A) PORTLAND,OR 97214 WIRE RUN FROM HOME RUN ID BRANCH BRANCH LENGTH CURRENT Phone-(541)316- 96 AC1 BRANCH TO Q BOX BRANCH 03 10 1.21 15.13 240 1 2 12 AWG Q-CABLE CU 25 0.94 1 23.50 30 0.47% N/A N/A 6 AWG FREE AIR N/A Contractor#OR CCB#:195141 1.21 15.13 240 1 2 10 AWG THWN CU 35 0.94 1 32.90 50 0.53% 20 N/A 10 AWG EMT REVISIONS AC2 Q BOX TO COMBINER BOX Q BOX 03 10 COMBINER BOX TO COMBINER N/A 45.38 240 1 2 6 AWG THWN CU 65 1.00 1 65.00 10 0.21% 50 6 AWG 6 AWG EMT 3/4" DESCRIPTION DATE AC3 INTERCONNECTION BOX MAX VOLTAGE DROP: 1.21% ELECTRICAL CONTRACTOR 10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 PROJECT NAME 1 1 4-- 1 4-- 1 -- 1 BI-DIRECTIONAL UTILITY (N)ENPHASE COMBINER METER 1-PHASE,3-W, W \— a PANEL(EXTERIOR) 120V/240V U m ❑ e TO UTILITY GRID z L1 L2 N LLI 10 MICRO-INVERTERS IN BRANCH CIRCUIT#2 z 10A 0 Ct = ti O O m 0.. Lc_—® i 20A L-— 1 LIVAII " © Z O 0 1 (N)SUPPLY SIDE O �$ L All - � � - --� A 1 (N)Q-BOX.(TYP) I° INTERCONNECTION J O 0 " - - 20A E o Q ( O N J I C O 20 (N)60A UTILITY REQUIRED 200A 2 Lo Q # F- 10 MICRO INVERTERS IN BRANCH CIRCUIT#3 NON-FUSED AC 6N 1-- k - DISCONNECT/RSID WITHIN 10' (N)60A FUSED AC o (E)200A MAIN SERVICE PANEL CO C� z D FROM UTILITY METER DISCONNECT r� WITH(E)200A MAIN BREAKER I[ H . . . ��. (INTERIOR) o RATED 120/240V(INTERIOR) w f Q m •. . C O (EXTERIOR) �! m 1 r-. W i i 1 C C IQ-Envoy 50A FUSES o 1 / 1 / 1 I C C .U_ 1 ti ; ti / Li n �° e e 1 L2 ° —J lr� o ❑ - L- -� �---- —FOAt IL N N N PROJECT I ENPHASE IQ7PLUS-72-2-US _ t G MICRO-INVERTERS(240V) LG- v G G} �/ -CT7 N/A (LOCATED UNDER EACH MODULE) AC1 AC2 (1)Q-CABLE (3)10 AWG THWN SHEET NAME (1)10 AWG THWN BRANCH TERMINATOR Q TERM (2)12 AWG TRUNK CABLE 1 GEC L.N GND -- FOR IQ SERIES(TYP.) (1)6 BARE CU GND IN 3/4"EMT CONDUIT AC3 ELECTRICAL LINE (2)6 AWG THWN GROUNDING DIAGRAM (1)6 AWG THWN NEUTRAL ELECTRODE SYSTEM (1)6 AWG THWN GND SHEET SIZE IN 3/4"EMT CONDUIT ANSI B GENERAL NOTES: 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL SHEET NUMBER QE LECTRICAL LINE DIAGRAM LOCAL OR NATIONAL CODE REQUIREMENTS AND PV-5 EQUIPMENT INSTALLATION INSTRUCTIONS. SCALE: NTS 2. SEE PV-6 FOR LABELING REQUIREMENTS M.-- \ ee ELEMENTAL ., y 1 SOLAR PV SYSTEM ENERGY �' 1 1/2 n 1339 SEPORTLA 8TH AVE. EQUIPPED WITH hone-(ND 316-5R 4 BRANCH#1 DISCONNECT N Phone-(541)316-5786 ` Phone OR CCB#:195141 240VAC 12.1 AAC )' )i' * RAPID SHUTDOWN REVISIONS DESCRIPTION DATE LOCATION: COMBINER PANEL QUANTITY:1 TWO POWER SOURCES PRESENT.SECOND SOURCE IS A PV ARRAY.SUPPLY SIDE CONNECTION IN THIS PANEL. MAIN SERVICE DISCONNECT LOCATED = X 1 1/2" X IN THIS PANEL.AC DISCONNECT AND RAPID c SHUTDOWN INITIATION DEVICE LOCATED OUTSIDE BRANCH#2 DISCONNECT iv ANEXT TO METER. ` 240VAC 12.1 AAC r SOLAR ELECTRIC --_. — _— PV PANELS ELECTRICAL CONTRACTOR LOCATION: INTERCONNECTION PANEL QUANTITY:1 LOCATION: COMBINER PANEL QUANTITY:1 K 1 1/2" X BRANCH#3 DISCONNECT iv )r 4" _ 240VAC 12.1 AAC WARNING:DUAL POWER SOURCES PRESENT. LOCATION: COMBINER PANEL QUANTITY:1 10950 WATT PHOTOVOLTAIC ARRAY LOCATED ON ROOF. TURN RAPID SHUTDOWN SUPPLY SIDE INSIDE AT MAIN SEVICE PANEL. MAIN SERVICE DISCONNEOCT N LOCATE INSIDE AT HOUSE MAIN ' SWITCH TO THE "OFF" PROJECT NAME SERVICE PANEL.AC DISCONNECT AND RAPID SHUTDOWN POSITION TO SHUT INITIATION DEVICE LOCATED OUTSIDE NEXT TO METER. ` W LOCATION: METER QUANTITY:1 DOWN PV SYSTEM AND U Z REDUCE SHOCK HAZARD : o 5.25" 2" IN THE ARRAY W > N 0 I rn CO w O 0 SOLAR AC DISCONNECT I 3i Z I CO Cl_ "-,_ r"�,_ -, . 240VAC 36.30 AAC 1 3 a Z 00 U RAPID SHUTDOWN SWITCH = LOCATION: MAIN SERVICE DISCONNECT QUANTITY:1 J >- CK o cn I— 3 OR SOLAR PV SYSTEM LOCATION: AC DISCONNECT QUANTITY:2 Q CV 00 - z W W LOCATION: RSD INITIATION DEVICE QUANTITY:1 'ji: I 4" 4" PROJECT '' 2" if' WARNING: I N G SHEET NAME WARNING LABELS ING VVARN • VVARN ELECTRIC SHOCK HAZARD. • TERMINALS ON THE LINE DUAL POWER SOURCES AND LOAD SIDES MAYBE PHOTOVOLTAIC SYSTEM - SECOND SOURCE IS c\I ENERGIZED IN THE OPEN N YSTEM POSITION. COMBINER PANEL SHEET SIZE PHOTOVOLTAIC S ANSI B RATED AC OUTPUT CURRENT: 36.3 AMPS AC LOCATION:AC DISCONNECT QUANTITY:1 AC NOMINAL OPERATING VOLTAGE: 240 VOLTS DO NOT ADD LOADS SHEET NUMBER J J PV-6 LOCATION: SOLAR DC DISCONNECT QUANTITY:1 LOCATION: COMBINER PANEL QUANTITY:1