Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (2)
CITY OF TIGARD MASTER PERMIT !hi . 'g.. COMMUNITY DEVELOPMENT Permit#: MST2022-00152 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/28/2022 Parcel: 2S 1070002000 Jurisdiction: Tigard Site address: 16882 SW COLORADO LN Subdivision: Lot: Project: South River Terrace, Lot 1 Project Description: New detached dwelling. NO FINAL UNTIL DEFERRED SDC FEES ARE PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 1297 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 5 Second: 1830 sf Garage: 564 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 3127 sf Value: $437,245.58 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 100 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add;500 sf: 6 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3127 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $28,153.07 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR o 9-nn1-M1n thrn,inh AP Q52M1.Mon htain a rnnv of tha rnlac nr rlirart n iactinnc to(11 INC by rallinn cf12 922 10A7 nr'I Ann329 924 4 Issued By: t 0. .7 Permittee Signature: )(Ccr c-,, Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. U Bulding Permit Application Residential FOR OFFICE USE ONLY Received C� \ 152 City of Tigard Dateiv : �' _ -� % Pik U 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ./.� ��,�( /�` Phone: 503.718.2439 Fax: 503.598.1960 Date/By: �(� ' PlCt ��UDO T 1 G A R D Inspection Line: 503.639.4175 Date Ready/By: Juris: HI See Page 2 for Internet: www.tigard-or.gov ted/MethodL720/ I Supplemental Information Q TYPE OF WORK. REQUIRED DATA:1-AND 2-FAMILY DWELLING 0 New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the work indicated on this application. CATEGORY OF CONSTRUCTION Valuation: $ QZ 37 2�� 0 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building El Multi-familyNumber of bedrooms: 5 ❑Master builder El Other: Number of bathrooms: 3 _Q JOB SITE INFORMATION AND LOCATION Total number of floors:2 3lp \ l Job site address: 16882 SW COLORADO LN New dwelling area: 3,127 square feet,C130 City/State/ZIP:Sherwood, OR 97140 Garage/carport area: 564 square feet 12-9l Suite/bldg./apt.no.: Project name:South River Terrace Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: South River Terrace Lot no.: I Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. New Construction/Type: SFU (4075 B) Valuation: $ Deferrals:Please defer TSDC and park SDC fees until occupancy. Existing building area: square feet V - — Projected start: April 2022 New building area: square feet 0 PROPERTY OWNER ❑ TENANT Number of stories: Name:Taylor Morrison Northwest LLC Type of construction: Address:703 Broadway St., Ste 710 Occupancy groups: City/State/ZIP:Vancouver,WA 98660 Existing: Phone:(360) 946-8674 Fax:( ) New: 0 APPLICANT ❑ CONTACT PERSON Ut9 BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:Taylor Morrison Northwest LLC Structural plan review fee(or deposit): Contact name:Omar Alami Abouhafs FLS plan review fee(if applicable): Address:703 Broadway St., Ste 710 Total fees due upon application: City/State/ZIP:Vancouver, WA 98660 - -- Amount received: Phone:(360)946-8674 Fax::( )360 693-4442 PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: 0AlamiAbouhafs@taylormorrison.com Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:Taylor Morrison Northwest LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:703 Broadway St., STE 710 Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver, WA 98660 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )360 695-7700 Fax:( )360 693-4442 State surcharge(12%of permit fee): $21.60 CCB lic.:207247 �/ ` Total fee due upon application: $201.60 Authorized signature: O .cyhu , E ,�/(mod This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Omar Alami Abouhafs Date:05/i 022 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) CEIVEC . .. •Mechanical Permit Applic R OFFICE USE ONLY � .' City of Tigard Received `J Permit No,: • 't 13125 SW Hall Blvd.,Tigard,OR 97223 MAY 1 9 2022 Date/By: i Plan Review Phone: 503.71$.2439 Fax: 503.598.1960 Datel9y: Other Permit: 7td'rAltl7 Inspection Line: 503.639.4175 CITY OF TIGARD Dale Ready/B : tads: 0 See awe Y Page 2 for Internet: stivrw.tigard-or.gov BUILDING DIVISI ON Notified/Method Supplemental Information TYPE OF WORK COMMERCIAL FEE* Sf mi)ULE —USE CHECKLIST Mechanical permit fees*are based on the value of the work A New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all cr Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT I SYSTEMS FEES* ® 1-and 2-family dwelling 0 Commercial/industrial El Accessory building Far special information use checklist- ', j Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Job site address: 16882 SW Colorado LN Air conditioning 46.75 46.75 Furnace 100,000 BTU(ducts/vents) f 46.75 46.75 City/State/ZIP:Tigard,OR 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: Project name: South River Terrace Heat pump 61.06 61.06� Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: South River Terrace Lot no.: 1 Other 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 — Flue vent for water heater or gas New construction-Type SFU fireplace 23.32 Log lighter(gas) 23.32 Woodipellet stove 33.39 Wood fireplace/insert 23.32 Cbimney/liner/flue/vent 23.32 ® PROPERTY OWNER 0 TENANT Other: 23.32 - Entironmental exhaust and ventilation: Name:Taylor Morrison Northwest LLC. Range hood/other kitchen 33.39 Address:703 Broadway St.,Ste.510 equipment 1 33.39 Clothes dryer exhaust 1 33.39 339 City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms, 23.332 toilet compartments,utility rooms) �� 23.32 Phone:(360)695-7700 Fax:( ) Atticicrawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other: 23.32 Fuel piping: Business name:Taylor Morrison Northwest LLC. SI4.I5 for first four,S4A3 for each additional Contact name: Omar Alami Abouhafs Furnace,etc. 1 Address:703 Broadway St.,Ste 510 Gas beat pump1 Wall/suspended/unit heater City/State/ZIP: Vancouver,WA 98660 Water heater Phone:(360)695-7700 Fax: :(360)693-4442 Fireplace 1 - Range 1 E-mail:permitsubmittalst taylormorrison.com Barbecue CONTRACTOR Clothes dryer(gas) Other: Business name:Pro Heating&Cooling MECHANICAL PERMIT FEES* Address: NW Alociek Dr,Ste.1104 Subtotal $262.84 City/State/ZIP:Hillsboro,OR Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(360)270-1590 I Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE 1 [ ( This permit application expires if a permit is not obtained within 180 li11 u ,. days after it has been accepted as complete. Authorized signature: C/c V tJ • Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date: 1 0/30/20 t-1NnitAiuorrrfmoertiSi' {A.m.Ann adn311 Ant Ann n:t-rr re,MI rrna.m,ca= Electrical Permit Applicati sit ECEIVED ma oilier, USE ONLY Er City of Tigard Received Permit 0: • 4 13125 SW Hall Blvd.,Tigard,OR 97223 HAY 1 9 2022 Date/By- Plan Review Phone: 503.718.2439 Fax 503.598.1960 Date/By: Related Permit 4: Inspection Line 503.639.4175 Ready Date/By: inns ra See Page 2 for TIGARD is Internet: www.tigard-or gov Notified/Method Supplemental Information TYPE OF WoRK CITY OF TI GARD PLAN REVIEW _ E New construction 0 AdditionialteraBtillonlil—reDpliNaeGemDenNt ISION Please check all that apply(submit 2 sets of plans+a,items checked) 0 Service or feeder 400 amps or store C]Building over three stories EJ Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings El less to ground,or exceeds 14,000 0 Commercial-use agricultural I-and 2-farnil dwelling 0 Commercial industrial EJ Accessory building amps for all other installations buildings 1, E] Multi-famjh 0 Master builder D Other: 0 Fire pump, 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION °Emergency system, larger separately derived 0 Addition of new motor load of system Job#: Job site address: 16882 SW Colorado LN 100HP or more. 0 Six or more residential units. occupancy,City/State/ZIP: Tigard,OR 97140 Health-care facilities 0 0 Recreational vehicle parks. Suite/bIdglapt.#: Project name: South River Terrace 0 Hazardous locations 0 Supply voltage for more than 0 Service or feeder 600 amps or more 600 volts nominal Cross street/directions to job site: FEE SCHEDULE DescripUon I QII. I Each I Total I • New residential single-or multi-family dwelling unit. Subdivision: South River Terrace Lot#: 1 Includes attached garage. 1,000 sq.tt.or less I 168.54 4 Tax map:pareel i---: Ea add'I 500 sq.ft.or portion Nkce 33.92 101.76 I DESCRIPTION OF WORK Limited energy,residential 75 09 2 (with above sq.ft.) Ness construction.'type SFU Limited energy,multi-family 75.00 2 residential(with above sq ft.) Renewable Energy 0 See Page 2 (21 PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name: Taylor Morrison Northwest LLC. 200 amps or less NK 100.70 100.7 2 ' Address: 703 Broadway St.,Ste 710 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Vancouver,WA 98660 601 amps to 1,000 amps 301,04 2 Phone:( 360 )946 8674 Fax:( ) Over I,000 amps or volts 552.26 2 Temporary'services or feeders installation,alteration,and/or Entail: 0AlamiAbouhafs0i taylormorrison.corn-PermitSubmittalsrdtaylormorrison.corn relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400:imps 125 08 2 401 amps to 599 amps 168.54 2 Owner signature: Date: ___ Branch circuits—new,alteration,or extension,per panel 0 APPLICANT El CONTACT PERSON A Fee for branch circuits with Business name:Taylor Morrison Northwest LLC. above service or feeder fee, 7 42 2 each branch circuit . Contact name: Omar Alami Abouhafs B.Fee for branch circuits without service or feeder fee,first Address: 703 Broadway St.,Ste 710 branch circuit 56 18 2 City/State/ZIP: Vancouver,WA 98660 Each add'I branch circuit 7 42 2 Miscellaneous(service or feeder not included) Phone:(360 )946 8674 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:0AlamiAbouhafs'ipaylormorrison.corn-PermitSubmittalsiilaylonnorrison.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: A LA iliED Pr LE-(- rj L, 4-k-C I . Sign or outline lighting 67.84 ' 2 Signal Circuit(s)or limited-enery 0 See Page 2 -, Address: 3'115 Ne Li Li hl (tlif._ panel,alteration,or extension. .. ci .,..7.2, s Each additional inspection over allowable in any of the above Cit)/StateIZIP:Fc,r_.--T-....11-1-ro , 0..r..... Additional inspection(I hr min) 66.25i hr Phone:( 5 i...-2., , 3 i©. zl 9 r.,5_ Fax:( ) Investigation(1 hr min) 90 00/hr . . Industrial plant(I hr min) 78 18/hr Email: 50 i.... Air_ oicei_ N\ ,C,c)(V1 Inspections for which no fee is , 001 hr CCB Lie.: 1 9, 1(4 3 Electrical Lic.: ' .61.4 3.- Suprv.Lic.: 9 154 S . specifically listed(V hr min) 90 I - ELECTRICAL PERMIT FEES Suprv. Electrician signature,required: C/)- 71//2-Z _ Subtotal. Print name:174v . I t...i si-r.v— Date: 10-,52.1- 0 Plan Review Required(25%of permit fee): $202.46 1:? State surcharge(12%of permit fee). Authorized signature. .N..*.....'"" l461,10.1.0 loom TOTAL PERMIT FEE: This pennit application expires if a permit is not obtained within 180 Print name: T74,,e_ --Thom es ce--) Date: 10-6-2.1 days sifter it has been accepted as complete. ' Number of inspections allowed per permit I 1BuildingTermits\ELC_PermitApp_ELR_EREdoc Rev OW 7/2015 440-4615T(I 1/05/COWLVEB • • ' Plumbing Permit Applicatinn ECEIVE1 g . . , Building Fixtures FOR OFFICE USE ONLY I City of Tigard MAY 19 2022 Received Permit No.: it 13125 SW Hall Blvd.,Tigard,OR 97223 t6ateBy. r(OF 1 IGARU Plan Review g Phone: 503.718.2439 Fax: 503.598.1'+11Other Permit No.: Date/By; TIGARD Inspection Line: 503.639,4175 BUILDING DIVISIOt' Date Ready/By: luris. 0 See Page 2 for Internet: www,ligard-or.gov Notified/Method. Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction 0 Demolition For special information use checklist. Description I Qry. I Ea. I Total 0 Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312,70 f`1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437,78 AccessorybuildingSFR(3)bath 1 500.32 500.32 ❑ 421-Multi-family Each additional bath/kitchen 25.02 0 Master builder 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 16882 SW Colorado LN Catch basin or area drain 18.76 City/State/ZIP:Tigard,OR 97224 Drywell,leach line,or wench drain 18.76 Footing drain(no,linear ft.:_) Page 2 Suite/bldg./apt.no.: I Project name:South River Terrace Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18,76 Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: South River Terrace Lot no.: 1 _ Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 New construction-Type SFU Clothes washer 25.02 25.02 Dishwasher Ni,,,,, 25,02 25.02 Drinking fountain 25,02 Ejectors/sump 25,02 0 I PROPERTY OWNER I 0 TENANT Expansion tank 12,51 Fixture/sewer cap 25.02 Name: Taylor Morrison Northwest LLC. Floor drain/floor sink/hub 25.02 Address:703 Broadway St.,Ste 510 Garbage disposal 25.02 City/State/ZIP:Vancouver,WA 98660 Hose bib \2, 25.02 50.04 Phone:(360)695-7700 Fax:( ) Ice maker 12.51 ® APPLICANT ❑ CONTACT PERSON Interceptor/grease trap 25.02 Business name: Taylor Morrison Northwest LLC. Medical gas(value.$_) Page 2 Contact name: Omar Alami Abouhafs Primer 12.51 Roof drain(commercial) 12,51 Address:703 Broadway St.,Ste 510 Sink/basin/lavatory 25.02 City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54 Phone:(360)695-7700 Fax::(360)693-4442 Tub/shower/shower pan 12.51 E-mail:permitsubmittais@taylormorrison.com Urinal 25.02 Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:G&B Plumbing&Sons Inc Water piping/DWV 56.29 Address:P.O.Box 92 Other. 25.02 City/State/ZIP:St.Paul,OR 97137 Subtotal 600.40 Phone:(503)868-1417 Fax:(971)727-8170 Minimum permit fee: 572.50 CCB Lie.:184372 Plumbing Lic.no.:pb634 Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature. , }{, iriy •••-__, TOTAL PERMIT FEE Print name:Steve Fowler Date: 10/30/20 This permit application expires if a permit Is not obtained within 180 days after It has been accepted as complete. "Fcc methodology set by Tri•Cowny Building Industry Service Board 1:\Boildinewemitot.mU-PcrmitApp.dre I0!01,09 440-461s'r(I0i62/COMAVE13) City of Tigard 11111 q COMMUNITY DEVELOPMENT DEPARTMENT T I G A R D Building Permit Review — Residential Building Permit #: ,4. 7 L 2,2 2— 'Ql 1/41 Site Address: i P} 2 9 CoU J4'w W Project Name: J C3v'f( ( er rap- Lot #: f Planning ReviewNJ Proposal: ++,,v( j G L & auuet[NA-9 ip Verify address/suite#active in Accela. In River Terrace: ❑ No AP Yes,River Terrace Review Addendum Site Plan Elements: ig.trosion Control pcopies of site plan on 8-1/2"x 11"or 11 x 17"paper -B ette+^P,-1 tree.Mnth dxi�Ji ne and-tre 7'Drawn to scale(standard architect or engineer scale) ootprint of new structure(including decks)and FFE :0 orth arrow tility locations&easements(required for new and additions) ''j►ite address,project or subdivision name and lot number Sidewalk/driveway approach Applicant information(name and phone number) of dimensions and building setback dimensions pStreet tree size,type and location quare oo age ' ng €treet names fl) ,i.s ir%stlftttuiesuu site f orner elevations (2'contours if more than 4'differential) PlLot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? JYes ❑No impervious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? `,es ❑No ic Clean Water Services-Service Provider Letter (lot platted prior to 9/10/1995): Required: ❑ Yes,applicant was notified R No Received: ❑ Yes ❑ No Qeh, Water Meter Fixture Unit Worksheet-Additions,Remodels and ADUs (( Required: ❑ Yes,applicant was notified kti No Received: ❑ Yes ❑ No SDC Exemption for ADU applied for: ❑ Yes ,No Received: ❑ Yes ❑ No CJ Public Facilities Improvement(PFI)Permit: Required: ❑ Yes,applicant was notified 4K`d No Applied For: ❑ Yes ❑ No,stop intake 1p Land Use Case#: PPt270 24 �> ,Zoning: a_':-.3.- x Required Setbacks: Front: Li Rear: Side: `3 Street Side:A' Garage2.O A Building Height: Max. Height: 3,r Actual Height: 5-' S— Landscape a: Z O % Ct Lot Coverage Max: eG % Entrance Set back no more than 8'from street-facing wall 1p Parallel to street or offset 45 degrees or less Windows Minimum 12%of area of all street-facing facades Garage p Garage door is behind widest street-facing wall Yes ❑ No,one of the following is met: ❑ Door extends no more than 5'from wall and there is a covered porch extending beyond garage. ❑ Door extends no more than 5'from wall and there is a 12 sq ft.window above garage on 2°d floor. i pi Garage door width is ❑ 12'or less () 50%or less of facade ❑ 60%or less and includes 7 of following: ❑ Covered porch ❑ Recessed entrance ❑ Wall offset ❑ 1'Roof eave ❑ Roof offset ❑ Fire shingles ❑ Lap Siding ❑ Roof pitch ❑ Gable,hip,or gambrel roof ❑ Dormer ❑ Accent siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ Balcony l "Visual Clearance X' Urban Forestry Plan Sensitive Lands: ❑ Yes 2 No Type: CA Conditions met prior to issuance of building per 't No s: Approved By Planning: t Dae:_4_ 22 Revisions (after Building Submittal only)/ Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw_RES_122419.docx Building Permit Submittal Original Submittal Date: Site Plans: # 3 Building Plans: # 3 Building Permit#: Er-Enter building permit#above. Workflow Routing: Iff—Planning •Cfil�.ngineering ,/u Permit Coordinator re-Building Workflow Sign-off: Sign-off for Planning(include notes from planning review) Route Application Documents: Engineering: (1) copy of permit application, (1) site plan, (1)building plan and �eriginal plan review routing form. /❑ Building: original permit application, site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: Date: S/,Z3-12 . En;ineering Review Slope at building pad: `d/ [ Conditions "Met"prior to issuance of building permit [J�' Easements (encroachments)per engineering conditions of approval and plat V Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes 1 No Assess Water Quantity Fee in-lieu: ❑ Yes [ ' No LIDA Facility on lot: ❑ Yes fT�No fp Final Plat Recorded: ❑ NOT Approved by Engineering: Date: Notes: (a" Approved by Engineering: Date: /Z4/22 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Permit Coordinator Review lip Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions(after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: 4-SDC Exemption: ❑ Received J" Does not apply SDC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A Tigard Trans SDC: Yes ❑ N/A AN Parks SDC: Yes ❑ N/A LIDA ❑ Yes yq N/A A ❑ OK to Issue Permit Approved by Permit Coordinator: Date: Z S ���I� L Q' ' 7L I:\Building\Forms\BldgPennitRvw_RES_122419.docx City of Tigard Deferral Until Occupancy Request TIGARD Washington County Transportation Development Tax (TDT),Transportation and Parks System Development Charges (SDCs) This form is to be signed and submitted prior building permit issuance or,if no building permit is required,then upon land use approval(TMC 3.24, as amended by Ordinance No. 21-09). Date: 6/6/2022 Site Address: 16882 SW Colorado Lane Project South River Terrace Land Use Case or MST2022-00152 Name: Building Permit#: Tax Lot Total Parks 2S1070001302 #: Lot 1 Amount*: $8,017.00 TDT Total TSDC N/A $10,348.00 Amount: Amount*: *The total TSDC amount shown above is the sum of$6,690.00 for TSDC-Improvement, $386.00 for TSDC- Reimbursement, and$3,272.00 for TSDC-River Terrace,if applicable.. *The total Parks SDC amount shown above is the sum of$ 6,278.00 for Parks-Improvement,$ 1,739.00 for Parks- Reimbursement,and either$ N/A for Parks-Neighborhood or$ N/A for Parks-Neighborhood River Terrace. This constitutes my request to defer payment of the TDT,TSDC, and Parks SDCs, as provided above, until occupancy. Payment of the TDT,TSDC, and Parks SDCs may be deferred until issuance of the occupancy permit. In requesting this option, I understand that any deferred TDT,TSDC, and Parks SDCs must be paid prior to final inspection or issuance of an occupancy permit. TDT may only be deferred if the TDT is greater than the amount for a single-family residence. I further understand that the amount of TDT due on deferred obligations shall be the amount in effect at the time of issuance of the building permit. For a deferral request to be accepted both the Property Owner and the Developer must sign this request. Property Owner: (Taylor Morrison NW LLC)Qm .4,4/a.iitu',A6eai Date: 6/6/2022 Developer: (Taylor Morrison NW LLC) 46 u 4'66.ijui6, Date: 6/6/2022 dal Permit Coordinator: 1 Date: 6/6/2022