Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (5)
CITY OF TIGARD MASTER PERMIT 11111 2 COMMUNITY DEVELOPMENT Permit#: MST2022-00185 Date Issued: 08/11/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S1070001305 Jurisdiction: Tigard Site address: 16683 SW COLORADO LN Subdivision: SOUTH RIVER TERRACE Lot: Project: South River Terrace, Tract M, Building 25 Project Description: New two-story triplex(Unit 2 of 3). NO FINAL INSPECITON UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 672 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 31 Bathrooms: 3 Second: 953 sf Garage: 287 sf Front: 0 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 0 Detectors: Total: 1625 sf Value: $226,909.86 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 100 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1625 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $14,701.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law re ires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Oc ..nM-nnin thrnl Inh nAR 9-nn1 on v I may nhtai runs,of th lilac nr rtircrt nl IPCtinnc to flu WC by raiiinn cril 919 1QR7 nr 1 Rnn 199 9'24A Issued By: 7I/1 -- rmittee Signature: 5,,- ')L, Call 503.639.4175 by 7:00 a.m.for the next available inspection date. ` fGGfv!' This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application RECEIVE PResidential FOR OFFICE USE ONLY City of Tigard ...NW: 0 r Dateiseya Permit No.: t It g 13125 SW Hall Blvd.,Tigard,OR 97223 ��� MST n,-(, l 09 = g ('�'�'�/ 1 Plan Review ry �+ Phone: 503.718.2439 Fax: 503.598.1960C�` OF T1Gi 1� D Date/By: tQ ?j Iwl, Other Permit:5 Ki1Z.7.^�do0 7 Inspection Line: 503.639.4175 1 Date ReadyBy: �� la s: lid See Page 2 for TIGARD Internet: www.tigard-or.gov BUILDING D1Uf51CJ1! ified/Method: !�/' Supplemental Information TYPE OF WORK -r ' REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the ofit for the n(„ CATEGORY OF CONSTRUCTION '.M . 0,01work indicated on this application. ti, r C ❑ 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ 161, ❑Accessory building ❑Multi-family Number of bedrooms: 3 ❑Master builder ®Other: ADU 1 Number of bathrooms: 3 JOB SITE INFORMATION AND LOCATION Total number of floors:2 c 1 6 2- Job site address: 16683 SW COLORADO LN New dwelling area: 1,625 square feet el S3 City/State/ZIP: Tigard,Oregon 97120 Garage/carport area: Pi3s7uare feet cop_ Suite/bldg./apt.no.: BLDG 25 Project name:South River Terrace Covered porch area: 5 .9 square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: South River Terrace Lot no.: TRACT M Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. New Construction/Type: 2 story triplex A(UNIT 2) Valuation: $ Deferrals:Park SDC& TSDC until occupancy. Existing building area: square feet Projected start: July 2022 New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Taylor Morrison Northwest LLC Type of construction: Address:703 Broadway St., Ste 710 Occupancy groups: City/State/ZIP:Vancouver, WA 98660 Existing: Phone:(360) 946-8674 Fax:( ) New: ® APPLICANT ❑ CONTACT PERSON Vi9 BUILDING PERMIT FEES* Business name:Taylor Morrison Northwest LLC (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name:Omar Alami Abouhafs Address: 703 Broadway St., Ste 710 FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP:Vancouver,WA 98660 Amount received: Phone:(360)946-8674 Fax: :( )360 693-4442 PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: PermitSubmittals@taylormorrison.com Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:Taylor Morrison Northwest LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:703 Broadway St., STE 710 Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver, WA 98660 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )360 695-7700 Fax:( )360 693-4442 State surcharge(12%of permit fee): $21.60 CCB lic.:207247 � � �/ Total fee due upon application: $201.60 Authorized signature: t.2hta t-, '/p�zJne-icy e& This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Omar Alami Abouhafs Date: 05/23/2022 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Mechanical Permit ApplicatiotflECEIVii FOR OFFICE USE ONLY - °., , City of Tigard "`d r/' �/ .�-�J� ( j7 Date/By:: (0 �v Permit No.: /U(S 1 w(/Z( I�j ' tr 13125 SW Hall Blvd.,Tigard,OR 97223 *1/t;Nf 0 's�0 Phone: 503.718.2439 Fax: 503,598.1960 a-' 7 ale/B Review De/13 aty: Other Permit:SW(Z 2Z oily T I drl,1.I) Inspection Line: 503.639.4175 CITY OF TIG A RDDme ReadyBy: Juris; ® See Page 2 for Internet: www.tigard-or.gov 1�1IllUNotifiedlMethod: Supplemental Information BUILDING DIVISION - TYPE OF WORK COMMERCIAL FEES SCI-IEDULE USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:S CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT I SYSTEMS FEES* D 1-and 2-family dwelling ❑Commerciallindustrial ❑Accessory building For special information use checklist. i j Multi-family ©Master builder ®Other: ADU 1 Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 1 46.75 46.75 Job site address: 16683 SW Colorado LN Furnace 100,000 BTU(ducts/vents) 1 46.75 46.75 City/State/ZIP:Tigard,OR 97224 Furnace 100.0001 B"Ili(ducts/vents) 54.91 Suite/bldg./apt.no.: 24 Project name: South River Terrace Heat pump1 b1.06 61.06 Duct work 23.32 Cross street/directions to job site: Flydronic hot water system _ 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: South River Terrace Lot no.: other 23.32 _ Other fuel appliances: Tax map/parcel no.: Water beater 23.32 DESCRIPTION OF WORK Gas fireplace/insert . 33.39 - Flue vent for water heater or gas New construction-UNIT 2 fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chitnney/liner/flue/vent 23.32 ... OWNER ❑ TENANT Other: _ 23.32 - • Environmental exhaust and ventilation: Name:Taylor Morrison Northwest LLC. Range hood/other kitchen 33.39 equipment 1 33.39 Address:703 Broadway St.,Ste,510 Clothes dryer exhaust 1 33.39 33.39 City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms, 1 23.32 toilet compartments,utility rooms) 23.32 Phone:(360)695-7700 Fax:( ) Attic/crawlspace fans , 1 23.32 23.32 1,.. APPLICANT ❑ CONTACT PERSON Other: 23.32 Fuel piping: Business name:Taylor Morrison Northwest LLC. s14.15 for first four;54.03 for each additional Contact name: Omar Alami Abouhafs Furnace,etc. 1 Address:701 Broadway St.,Ste 510 Gas heat pump 1 Wall/suspended/unit heater City/State/ZIP: Vancouver,WA 98660 Water heater 1 Phone:(360)695-7700 I Fax::(360)693-4442 Fireplace 1 Range 1 E-mail:permitsubnsittais(taylormorriSOn.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:Pro Heating&Cooling Other: MECHANICAL PERMIT FEES* Address: NW AJociek Dr,Ste.1104 Subtotal $267.98 City/State/ZIP:Hillsboro,OR Minimum permit fee(S90.00) Plan review(25%of permit fee) Phone:(360)270-1590 Fax:( ) ' State surcharge(12%of permit fee) CCB lic.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 Z&� b Z.A. days after it has been accepted as complete. Authorized signature: • Fee methodology set by Tri.County Building Industry Service Board Print name:Elia Duran Date: 10/30/20 1-1PrrilAno1P.rmrrdAfFr Peen.Ann WW1 11 rin Electrical Permit Application RECEIV " FOR OFFICE USE ONLY City of Tigard Jr .1 ° '12 DateBiv y: 0 iaZ 5-Qv Permit#:M51-7O Z2-OO L YTS 11 13125 SW Hall Blvd.,Tigard,OR 97223 ',Ilan Review �f,1 O ff^. Z� �J/ i Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TI GrA',Ilan Re: Related Permit#: W It GV 7 1 Inspection Line: 503.639.4175 R h h n r 1 eady DateBy: Suns 0 See Page 2 for 1 1('A k I) Internet: www.tigard-or.gov BUILDIN '� t ' jluotiSed/Method: Supplemental Information `". TYPE OF WORK PLAN,REVIEW ®New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): O Service or feeder 400 amps or more ❑Building over three stories. O Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. O 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ❑Master builder ®Other: ADU 1 ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 16683 SW COLORADO LN 1001IP or more. ❑"A","E","1-z","1-3", 0 Six or more residential units. occupancy. City/State/ZIP: Tigard,Oregon 97140 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bld /a t.#: Project name: South River Terrace 0 Hazardous locations. 0 Supply voltage for more than g• P BLDG 25 j 600 volts nominal. ❑Service or feeder 600 amps or more. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: South River Terrace Lot#: TRACT M Includes attached garage. 1,000 sq.ft.or less 1 168.54 4 Tax map/parcel#: Ea.add'1500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 New home construction UNIT 2 (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 ❑ PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: Taylor Morrison Northwest LLC 200 amps or less 1 100.70 2 2 Address:710 Broadway St,STE 710 201 amps to 400 amps 133.56 401 amps to 600 amps 200.34 City/State/ZIP: Vancouver,WA 98660 601 amps to 1,000 amps 301.04 2 Phone:(360 )695 7790 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: PermitSubmittals@taylormorrison.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ❑ APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: Taylor Morrison Northwest LLC above service or feeder fee, 7.42 2 each branch circuit Contact name: Omar Alami Abouhafs B.Fee for branch circuits without service Address:710 Broadway St,STE 710 branch circuit fee,first 56.18 2 City/State/ZIP:Vancouver,WA 98660 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(360 0)5 7700 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email:PermitSubmittals@taylormorrison.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Sunlight Electric Inc Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy ❑ See Page 2 2 Address:2804 NE 65th Ave, Sutie D panel,alteration,or extension. ry Vancouver WA 98661 Each additional inspection over allowable in any of the above City/State/ZIP: Additional inspection(1 hr min) 66.25/hr Phone:( 971) 222-5758 Fax:( ) Investigation(1 hr min) 90.00/hr Email:Peter@SunlightElectricinc.com Industrial plant(1 hr min) 78.18/hr g Inspections for which no fee is CCB Lic.:172549 Electrical Lic.:c 0 Suprv.Lia:6652S specifically listed(''/s hr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name:Yegor Shevchen ko Date: 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: !!���",, )',tom/ TOTAL PERMIT FEE: """ ' This permit application expires if a permit is not obtained within 180 Print name:Peter Kozarez (/ Date: days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440.4615T(l l/05/COM/WEB Plumbing Permit C ApplicationECElVC ' Building Fixtures i �1 FOR OFFICE USE ONLY City of Tigard Jfjt't OE 2C12 Received g / Permit No.: tilh ir 13125 SW Hall Blvd.,Tigard,OR 97221.... PDate/B 817 2� 5 "4)74 3 Phone: 503.718.2439 Fax: 503.598.1 an Review Sl ��l''00, TryY OFT}IGARD Date/By: Other Permit No.: TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: turn; El Sec Page 2 for Internet: www.ligard-or.gov Notified/Method. _ Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑Demolition For special information use checklist. Description -I Qty. I Ea. I Total ❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(l)bath 312.70 I-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 SFR(3)bath 1 500.32 500.32 IX)Accessory building Multi-family Each additional bath/kitchen 25.02 ❑Master builder 0 Other: Fire sprinkler(_sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: 16683 SW Colorado LN Catch basin or area drain 18.76 Job site address: • City/State/ZIP:Tigard,OR 97224 Dtywell,leach line,or trench drain 18.76 Footing drain(no linear ft,:_) I Page 2 Suite/bldg./apt.no.: .z.s I Project name:South River Terrace Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18,76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft:_) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: South River Terrace Lot no.: el Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 New construction-UNIT 2 Clothes washer 1 25.02 25.02 Dishwasher 1 25.02 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER I ❑ TENANT Expansion tank 12.51 Fixture/sewer cap 25.02 Name: Taylor Morrison Northwest LLC. Floor drain/floor sink/hub 25.02 Address:703 Broadway St.,Ste 510 Garbage disposal 25.02 City/State/ZIP:Vancouver,WA 98660 Hose bib 2 25.02 50.04 Phone:(360)695-7700 Fax:( ) Ice maker 12.51 ® APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02 Business name: Taylor Morrison Northwest LLC. Medical gas(value:S ) Page 2 Contact name: Omar Alami Abouhafs Primer 12.51 Roof drain(commercial) 12.51 Address:703 Broadway St.,Ste 510 Sink/basin/lavatory 25.02 City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54 Phone:(360)695-7700 Fax::(360)693-4442 Tub/shower/shower pan 12.51 Urinal 25.02 E-mail:permitsubmittalsCtaylOrmOrriSOn.COm CONTRACTOR Water closet 25.02 Water heater 37.52 Business name:G&B Plumbing&Sons Inc Water piping/D14V Sb?9 Address:P.O.Box 92 Other. 25.02 City/State/ZIP:St.Paul,OR 97137 Subtotal 600.40 Phone:(503)868-1417 Fax:(971)727-8170 Minimum permit fee: 572.50 CCB Lie.:184372 Plumbing Lic.no.:pb634 Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: }�, TOTAL PERMIT FEE Print name:Steve Fowler Date: 1 0/30/20 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board L\BuildingdPenntts 'LMU-FermirApp.doc 10/01/09 44D-4616T(1O'02/COM'WEB) City of Tigard "� COa 11 MMUNITY DEVELOPMENT DEPARTMENT T c A It D Building Permit Review — Residential Building Permit #: 145 2Z-0010 Site Address: 1 Cp6083 S' Cr[ 12k4 0 Lh Project Name: ()J4 A e l\i er ( -e-rro. C-e Lot #:Taid 'Y) Planning Review Pro osal: new (0) L&)hots &-C__ N Verify address/suite #active in Accela. Lg In River Terrace: ❑ No ❑ Yes,River Terrace Review Addendum Site Plan Elements: L�Erosion Control opies of site plan on 8-1/2"x 11"or 11 x 17"paper -� ��I'€ t�ith drip line and tree protection measures IV rawn to scale(standard architect or engineer scale) �otprint of new structure(including decks) and FFEYr orth arrow L'��,U�tility locations&easements(required for new and additions) pIJS e address,project or subdivision name and lot number V idewalk/driveway approach plicant information(name and phone number) Lou of welts/septic systems "a/Lot dimensions and building setback dimensions Sitspertree size,type and location 2Str -names ^81 g stru iwres o i site [ omer elevations (2'contours if more than 4'differential) L foot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? ❑Yes ❑No impe •ous area (applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? ❑Yes ❑No Clean Water Services-Service Provider Letter(lot platted prior to 9/10/1995): Re uired: ❑ Yes,applicant was notified ❑ No Received: ❑ Yes ❑ No Water Meter Fixture Unit Worksheet-Additions,Remodels and ADUs Re uired: ❑ Yes,applicant was notified ❑ No Received: ❑ Yes ❑ No -JDC Exemption for ADU applied for: El Yes ❑ No Received: ❑ Yes ❑ No M Public Facilities Improvement (PFI) Permit: _/Required: CI Yes,applicant was notified ❑ No Applied For: NJ Yes ❑ No,stop intake L� Land Use Case #:12D Y-ZC) I -O()C C� 3 `SC Zoning: �-' ` u _/ ` Garage: KJ I L`� equired Setbacks: Front: �j Rear: � � Side: Street Side: � ' ding Height: Max. Height: SG Actual Height: -31 IV Landscape a: 2 % [ Lot Coverage Max 0 cyo Entrance C et back no more than 8'from street-facing wall I 1 Parallel to street or offset 45 degrees or less WindowsMinimum 12%of area of all street-facing facades • arage ❑ Garage door is behind widest street-facing wall ❑ Yes ❑ No,one of the following is met: ❑ Door extends no more than 5'from wall and there is a covered porch extendin b ytl-gar. xtends no more than 5'from wall and there is a 12 sC fx. ' ow above garage on 2"a floor. ❑ Garage door width is ° ss of facade ❑ 60%or less and includes 7 of following: ❑ Covered porch sed entrance ❑ a offset . 1'Roof eave ❑ Roof offset s tng es ❑ Lap Siding ❑ Roof pitch ❑ Gable,hip,or gam re ro - mer � ❑ Accent siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ Balcony 53 Visual Clearance El Urban Forestry Plan ,ensitive Lands: El Yes No Type: Ltd' Conditions met prior to issuance of building permit Not li Approved By Planning: .. (�), �` 1✓\v 1 i 5 Date: (1(6 !ZZ- Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: El Approved ❑ Not Approved I:\Building\Fomis\BldgPermitRvw RES_122419.docx Building Permit Submittal/ (zo Original Submittal Date: (a0 v— Site Plans: # Building Plans: # ---- Building Permit#: Enter building permit#above. Workflow Routing: :11 Planning p Engineering Eflt Permit Coordinator ,)Building Workflow Sign-off: ,P Sign-off for Planning(include notes from planning review) Route Application Documents: Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. Building. original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: Date: �Z Engineering Review [ Slope at building pad: 2 0 �o 140 Conditions "Met"prior to issuance of building permit Easements (encroachments)per engineering conditions of approval and plat Water Quality/Quantity Facility: L Assess Water Quality Fee in-lieu: ❑ Yes 1[2' No Assess Water Quantity Fee in-lieu: ❑ Yes sr No LIDA Facility on lot: ❑ Yes LJ No Add Fee: ❑ Yes ❑ No ❑ Final Plat Recorded: ❑ NOT Approved by Engineering: Date: Notes: L Approved by Engineering: Date: 7" 2e Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Permit Coordinator Review Conditions "Met"prior to issuance of building permit ❑ Approved, NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: SDC Exemption: ❑ Received g.Does not apply SDC Fees Entered: Wash Co Trans Dev Tax: ,o Yes ❑ N/A se., Tigard Trans SDC: /Yes ❑ N/A Parks SDC: 7 Yes ❑ N/A ms ' LIDA ❑ Yes ,Z N/A / OK to Issue Permit Approved by Permit Coordinator: 7Arrrl Date: IS �21L- t I:\Building\Forms\BldgPermitRvw RES_1208021.docx City of Tigard Deferral Until Occupancy Request T I G A R D Washington County Transportation Development Tax (TDT),Transportation and Parks System Development Charges (SDCs) This form is to be signed and submitted prior building permit issuance or, if no building permit is required,then upon land use approval(TMC 3.24, as amended by Ordinance No. 21-09). Date: 7/18/2022 Site Address: 16683 SW Colorado Lane Project South River Terrace Land Use Case or MST2022-00185 Name: Bldg 25 Building Permit#: Tax Lot 2S107AD05700 Total Parks #: Tract M Amount*: $5,839.00 TDT N/A Total TSDC Amount: Amount*: $6.037.00 *The total TSDC amount shown above is the sum of$ 3,903.00 for TSDC-Improvement,$225.00 for TSDC- Reimbursement,and$1,909.00 for TSDC-River Terrace,if applicable.. *The total Parks SDC amount shown above is the sum of$4,727.00 for Parks-Improvement,$ 1,112.00 for Parks- Reimbursement,and either$ N/A for Parks-Neighborhood or$ N/A for Parks-Neighborhood River Terrace. This constitutes my request to defer payment of the TDT,TSDC, and Parks SDCs, as provided above, until occupancy. Payment of the TDT,TSDC, and Parks SDCs may be deferred until issuance of the occupancy permit. In requesting this option, I understand that any deferred TDT,TSDC, and Parks SDCs must be paid prior to final inspection or issuance of an occupancy permit. TDT may only be deferred if the TDT is greater than the amount for a single-family residence. I further understand that the amount of TDT due on deferred obligations shall be the amount in effect at the time of issuance of the building permit. For a deferral request to be accepted both the Property Owner and the Developer must sign this request. Property Owner: Dmc�z.4 mo,46&-a (Taylor Morrison NW) Date: 07/18/2022 Developer: ()mem..A&.mo'.A6elih:'c (Taylor Morrison NW) Date: 07/18/2022 Permit Coordinator: iv/ %� Afrt %kO Date: 7/18/2022