Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
I- PROPERTY LINE U J W W C Z Q Z 0 0 a m 0 0 0 0 W Li) I" V f OFFICE COPY °' w G l- O cc Ilia Ce W ❑ ❑ ❑ Q Z 0 II: peE Wri) Q Z I nJa ° 0Z = W LLI > it . WZ = H2u- ZQZQ � > 1-1 O W 0 _1 N 1.-1 I 1 a Q W } LIABILITY co cc The City of Tigard ant, F- a employees shall not )e —I 0 responsible for discrep Ides EL which may appearhe sin. 0 J J 0 CITY OF TIGARD I REVIEWED FO!t 'ODE COMPLI .NCE ~ Approved plans W Ap>>ro, cd: [ oha!l be on =ob s '-�,.. pe OTC: [ 1 0 Perm it #: Yv\,S'ZOZI —UbD$�� 0 ° ° ❑ LL VALIDITY OF PERMIT Adcfire : �j t. J.... ,a (� THE ISSUANCE OF A PERMIT Suite tit BASED ON CONSTRUCTION By: _ kik Date: 3/24( PROPERTY LINE DOCUMENTS AND OTHER DATA SHALL NOT PREVENT (23)MODULES QUALIFY FOR ETO=8.51KW THE CODE OFFICIAL FROM (6)MODULES DO NOT QUALIFY FOR ETO=1.11KW RIQUtRING THE CORRECTION OF ERRORS. ORSC 105.4 SOLAR OWNER: BUILDING APPLICABLE ROOF SPECS: SYSTEM INFO: ENERGY CONTRACTOR: DATA: CODES: COMPOSITION SHINGLE ROOF (26)SILFAB 370-WATT MONO ELITE ALL Solutions ENERGY SOLUTIONS LLC SHAN RANDALL 1-2 FAMILY 2019 OREGON W/2X4 PRE-ENGIN.TRUSSES BLACK SOLAR MODULES ...- - PO BOX 887 17303 SW FOREST DEWELLING- STRUCTURAL DOUGLAS FIR#2 @ 24"ON (26)ENPHASE IQ7+MICRO INVERTERS W/ A W BEAVERCREEK,OR 97004 HOLLOW ST ADDITION INSTALLATION CENTER (1)AC COMBINER PANEL WITH BUILT IN 503.680.3718 BEAVERTON OR 97007 SPECIALTY ROOF AREA=2,006'SQ ENVOY MONITORING Z lip-to CCB#202002 919.265.9945 CODE TILT= 26 DEGREES SYSTEM SIZE=9.62 KW AZ= 90&270 DEGREES SYSTEM AREA=509'SQ>25% 3 2017 NEC CODES LOWEST READING=75%TSRF 3111.4.8.1General Pathway Requirements.All PV installations shall include a 36 inch wide(914mm)pathway maintained along three sides of 20�3 ~3.1,• 2��3 the solar roof.The bottom edge of a roof with a slope that exceeds 2:12 � 1 shall not be used as a pathway.All pathways shall be located over a - structurally supported area and measured from edge of the roof and horizontal ridge to the solar array or any portion thereof. 3' 3'- U•P POR_.D--PATHWAY Exception: ---❑ .0__ __ ❑--- 1.On structures with a PV array area of 1,000 square feet(92.90 m2)or less , installed on a roof with a slope that exceeds 2:12 and with an intersecting --- --- adjacent roof and where no section is larger than 150 feet(45720 mm) i• i• measured in length or width: 1 I ❑ 1.1.Where the PV array does not exceed 25%as measured in plan view of I-- -- ___ ___ .--- -� -- total roof area of the structure,a minimum 12 inch(305mm)unobstructed I I I pathway,shall be maintained along each side of any horizontal ridge. ; 1.2.Where the solar array area exceeds 25%as measured in plan view of !. ___ ___ ... total roof area of the structure,a minimum of one 36 inch(914 mm) ❑ i ' . • i a unobstructed pathway from ridge to eave,over a structurally supported - i i i area,must be provided in addition to a minimum 12 inch(305 mm) i ; ___ __- _ ;.,.__, , unobstructed pathway along each side of any horizontal ridge. 'p 3111.4.8.4 Smoke and Heat Vents.In structures where smoke and heat FL - ' '-- '-- ' " • i i i i vents have been installed to comply with the requirements of the Fire 41 1 i i 1 a Code,Chapter 9 Smoke and Heat Vents and Chapter 32 High Piled Storage, i i i a 36 inch(914mm)wide pathway to and around each vent shall be i provided for fire department access,maintenance and testing of these 1 1 ' ' I vents. i' i i i 3111.4.8.5 Electrical Component Location. - • --- --- I 3111.4.8.5.1 Disconnects,j-boxes,combiner boxes or gutters shall not be _ i i located in any required pathway or cutout. 3111.4.8.5.2 Raceways on flat roofs that cross a required pathway shall be i i ' !_-- ' bridged to avoid tripping hazards.Raceways shall not be permitted in i i required pathways on roofs with a slope that exceeds 2:12(17-percent - i T I --- --- : i slope). ❑ i, i i • i i ; i ❑ N � i , 1 i i i 41 LOWEST READING STANDOFFS ARE ATTACHED EVERY 24" IF LOCATED WITHIN 3'OF ANY HIP, EAVE, RIDGE, OR VALLEY PER CODE. IF OVER 3', STANDOFFS ARE ATTACHED EVERY 48" ON CENTER. ENERGY SOLUTIONS,LLC SHAN RANDALL N PO BOX 887 17303 SW FOREST HOLLOW ST BEAVERCREEK, OR 97004 BEAVERTON OR 97007 A ENERGY 503.680.3718 919.265.9945 W 1' E CCB#202002 9.62 KW SOLAR ARRAY-RESIDENTIAL Solutions ENLARGED ROOF PLAN S 20'3" 12---►3'1"1-1 20'3" 3' - -3'-SUP-POR-€D PATHWAY - ---� n-- -_ - a---- i i i 1 i i i i ❑ i f f i i i i i _ : i 111111 i - i i i i i i i i ❑ i i . ■ ii i ❑ i i i i i i i f� i - --- --- i i q+ i 1 1 i 1•+ i i i i O. i i i i i i i i ----n • i � - - • i • ❑---- i i i i i i i i i i i i ri --- --- i i i i i i f 1 1 - i i i i i i i i i • i --- --- i 1 i - i i i i i i i i i i i i i i i i 1 i i i i i i i i I i i i i i i 0 i i i i . • i i i i ❑ I i i I i i i i N i i i i i 4I LOWEST READING I I System Information Labels PV Module Ratings Inverter Ratings Photovoltaic AC Disconnect Module Make Silfab Inverter Make Enphase AC Output Current = 31.5 A ENERGY Module Model SIL-370 BK Inverter Model IQ7PLUS-72-2-US Nominal AC Voltage = 240 V Max Power = 370 W Max. Output Power = 290 W PV System meets requirements Solutions Open Circuit Voltage = 44.76 V Max. DC Voltage = 60 V Max Power Point Voltage = 38.34 V Norminal AC Voltage = 240 V for Rapid Shutdown as defined P.O. Box 887 Short Circuit Current = 10.33 A Max. AC Current = 1.21 A in 690.12 Beavercreek, Oregon 97004 Max Power Point Current = 9.69 A CEC Inverter Efficiency = r97.0% Phone: 503-680-3718 Meter Base ILITY SERVIC O©© 4<? ©O 4 Main O OCPD I)200A 414 13 Modules w/ J-Box AC Main Solar f! Micro-inverters (at array) " '1. Branch#1 Combiner ACeTh ,I -——————— Panel Disconnect —40A T 13 Modules w/ —w/(2)20A Unfused Circuit - - Main / 1,111 Micro-inverters Breakers I__ Meter — Branch#2 _ _—_ ) Service — — G Panel 200A Bus A B lip D 0 BUILDING GROUNDING— ELECTRODE EQUIPMENT SCHEDULE REF DESCRIPTION FN NOTES 1 SOLAR PV MODULE SIL-370 BK SILFAB ELITE 370W MONOCRYSTALLINE MODULE,ALL BLK Notes: 2 AC/DC MICRO-INVERTER IQ7PLUS-72-2-US ENPHASE290W MICROINVERTER o Equipment, conductors and conduit 3 ARRAY HARDWARE TBD SUNMODO FLUSH MOUNT ROOF RACKING,ALL BLACK as listed or equivalent. 4 JUNCTION BOX TBD FOR TRANSmON FROM TRUNK CABLE TO NM CABLE(ROMEX) o DC side of the Micro-Inverter is 5 AC COMBINER PANEL X-IQ-AM1-240-2 ENPHASE IQ COMBINER+PANEL W/IQ ENVOY, 125A BUS BAR isolated. A DC CEG is not required. 6 BRANCH CIRCUIT OCPD BRK-20A-2-240 EATON BR220,20A,2-POLE,240V CIRCUIT BREAKER(BACK-FED) ONE-LINE STANDARD ELECTRICAL DIAGRAM 7 MAIN SOLAR AC DISCONNECT DU222NRB SQUARED,SAFETY SWITCH,60A,240V,2-POLE,40A FUSING PROJECT REF: Shan Randall 8 MAIN SOLAR OCPD TBD 40A,240V,2-POLE CIRCUIT BREAKER(BACK-FED) SfTE ADDRESS: 17303 SW Forest Hollow St, 9 MAIN SERVICE PANEL N/A 200A MAIN BREAKER W/200A BUS,240V(EXISTING) Beaverton,OR 97007 SYSTEM SIZE 9.62 kW CONDUIT&CONDUCTOR SCHEDULE 2 Branches of 13 Modules/Inverters(Silfab 370W PLV DESCRIP./CONDUCTOR TYPE CONDUCTOR GAUGE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE Elite/Enphase IQ7-Plus) A ENPHASEQ-12-10-240 CABLE #12 2(Per Cable) IN FREE AIR B BARECU #6 1 IN FREE AIR Sheet 1 of 3 C NM or NMC(Romex) #12/#10 2/1 (x 2) IN FRQAIR Date: March 3, 2021 D THWN-2 #8/#8 3/1 EMT 1" NOT TO SCALE PORTLAND/HILLSBORO Elev. High Temp Distance above roof Extreme ENERGY -4- 0.4% 2%Avg. 0.5" 3.5" 12" Min 62 m 37 °C 32 'C 54°C 49 °C 46 °C -8 °C Solutions Correction Temperatures Voltage Drop calculations: ATe°,d=-8°C-25°C=-33°C ATh°t=(37°C+35°C)-25°C=47°C DC voltage drop is insignificant because of micro-inverters mounted P.O. Box 887 Beavercreek,Oregon 97004 Flush Roof Mount at PV modules. Phone: 503 680 3718 Module Voltage Calculations Per Enphase Technical Brief on Calculating AC Line Voltage Rise for Silfab Elite 370W Mono(SIL-370 BK) IQ-Series Micros with Q Cable for center termination of IQ7+,240V, Voc=44.76V Vmp=38.34V Voc Temp Coefficient=-0.279%/°C portrait trunk cable, Branch Circuit AC voltage drop for 13 micro- Isc= 10.33A Imp=9.69A Pmax Temp Coefficient=-0.377%/°C inverters center-tapped is given as 0.24%. Cold Voc=44.76V+(44.76V x-0.279%/°C x-33°C)=44.76V+4.12V=48.9V AC conductor run from junction box to ac combiner is 50 ft(est) Hot Vmp=38.34V+(38.34V x-0.377%/°C x 47°C)=38.34V-6.79V=31.5V Micro-inverter output voltage is 240V, 1.21A x 13= 15.7A (2 x 50ft x 15.7A x I.980/kft x 100)/(1000ft/kft x 240V)= 1.30% Enphase IQ7PLUS-72-2-US Max DC Input Voltage: 60V Max DC Isc: 15A AC conductor run from AC Combiner to Interconnection is 10 ft(est) DC Operating range: 16V-60V Peak Power Tracking Voltage: 27V-45V Micro-inverter output voltage is 240V, 1.21A x 26=31.5A AC output voltage:240V AC output current: 1.21A (2 x 10ft x 31.5A x 0.778(-2/kft x 100)/(1000ft/kft x 240V)=0.20% Max Branch Circuit Size: 13 Max Branch Circuit OCPD: 20A 0.24%+ 1.30%+0.20%= 1.74%total worst case voltage drop Conductor Ampacity.OCPD&Disconnects Branch Circuit: 1.21A x 13 x 125% = 19.7A Conditions of use-2 branch circuits in nonmetallic sheathed cable(2 current carrying conductors per)not on the roof: 19.7A+ 1.0= 19.7A #12 AWG NM(rated for 20A into 60°terminals and required OCPD) 20A,240V,2-Pole Back-Fed Circuit Breaker in AC Combiner Panel AC Combiner Output Circuit: _ A 3 125%121Ax26x -39. #8 AWG(rated for 50A into 75°terminals and required OCPD) 40A,240V,2-Pole, Back-Fed Circuit Breaker in the Main Service Panel 60A,240V, 2-Pole, Unfused AC Disconnect adjacent to the utility meter. Table 1.10:Internal Q Cable VRise (Portrait Cable, Q-12-10-240) IQ 7+ 240V P IQ 7+Microinverters per branch ELECTRICAL CALCULATIONS PROJECT REF: Shan Randall 1 2 3 4 5 6 7 8 9 10 11 12 13 SITE ADDRESS: 17303 SW Forest Hollow St, Beaverton,OR 97007 Current(A) 1.2 2.4 3.6 4.8 6.0 7.3 8.5 9.7 10.9 12.1 13.3 14.5 15.7 SYSTEM SIZE 9.62 kW 2 Branches of 13 Modules/Inverters(Silfab 370W VRise(V) 0.02 0.06 0.12 0.20 0.31 0.43 0.57 0.73 0.92 1.12 1.35 1.59 1.86 Elite/Enphase IQ7-Plus) Sheet 2 of 3 VRise(%) 0.01 0.03 0.05 0.09 0.13 0.18 0.24 0.31 0.38 0.47 0.56 0.66 0.77 Date: March 3, 2021 Notes: • PV System compliant with requirements for Rapid Shutdown per 690.12. • Each microinverter is attached to the racking at the back of the corresponding PV ENERGY module. • Enphase Raw Q Cable(#12 AWG)is used to span from the Enphase Q Trunk rl So�utio5 cable of each branch to the penetration through the roof. Once below the roof, Solutions conductors are transitioned to Nonmetallic Sheathed Cable(Romex or equivalent). The Raw Q Cable is installed below the array and attached to P.O. Box 887 racking frame members. Beavercreek, Oregon 97004 • Branch circuits penetrate the roof where the transition from Enphase Raw Q Phone: 503-680-3718 Cable to Nonmetallic Sheathed Cable is made. "Junction Box"shown on sheet 1 is typically some kind of Soladeck brand box flashed into the composite roofing. Installer will probably have multiple roof penetrations. • The Enphase AC Combiner Panel will be located inside the residence's garage, I adjacent to the Main Service Panel. The Main Solar AC Disconnect will be located outside,adjacent to the Utility Meter on the east facing side of the residence. • The Enphase AC Combiner Panel includes an integrated Enphase Envoy system for monitoring PV System performance. Communication is via WiFi to the residence's router. No additional wiring is required. • Nonmetallic Sheathed Cable will be run(per Code)in open space. No deratings for condition of use will be required. • Conductor sizing for the NMC is minimum required to meet ampacity calculations. Current carrying conductors may be upsized due to needing cable that meets the #10 AWG minimum ECG size for the branch circuits. • Circuit breakers in the AC Combiner Panel serve as disconnecting means for each branch of microinverters. • The Q Cable will be connected in a"Center-Fed"configuration to minimize AC voltage drop in each branch. • Enphase recommends maintaining a total voltage drop for 2%or less from the array to the point of interconnection, and a less than 1%for the Q Cable. • Conductor run lengths and voltage drop to be confirmed. Conductors will be upsized as required to maintain 2%or less total voltage drop. • Interconnection via a back-fed circuit breaker in the Main Service Panel. Complies with 705.12. • Conductor sizing listed is minimum required based on NEC ampacity calculations for CU conductors or voltage drop calculations. • Conduit sizing based on listed conductors and NABCEP recommended maximum fill of 25%. Conduit sizing may need to be recalculated for conductors of a different type. Conduit may be sized to comply with NEC,Annex C. Minimum recommended conduit size is 3/4". • All electrical work must be made in accordance with the local and applicable National Electrical Code ANSI/NFPA 70. DESIGN/BUILD NOTES • PV System to be installed and labeled per National Electric Code. Specifically: PROJECT REF: Shan Randall 690.4(D) 690.31(B) SITE ADDRESS: 17303 SW Forest Hollow St, -690.5(C) -690.35(C)and(F) Beaverton,OR 97007 -690.13(B) -690.5(C) -690.17(E) -705.12(D) SYSTEM SIZE 9.62 kW • Inverters listed to UL-1741 for grid-interactive use and GFDI protection. 2 Branches of 13 Modules/Inverters(Silfab 370W • All equipment,conductors&conduit as listed or equivalent. Bite/Enphase IQ7-Plus) • All equipment used is UL listed. Sheet 3 of 3 Date: March 3, 2021 , li --- RECEIVED MODULE END CLAMP RAFTER or PRE-ENGINEERED TRUSSES MAR 1 0 2021 I I I J IIJ-L- IIJ-�- IILI I Y OF TIGARD ri-- __i_L 11 r- 11 r- 11 -i r- 1 ( -I r--- 1I 1 1 I I I I I 1 1 I 1 i i ' 1 1 1 1 _ 1 I i 1 i 3UILDING DIVISION MODULE CLAMP 1- 1 1 1 1 tali COMPOSITION ROOF /Y 1 400/00100%"---1441110116' PV MODULE TYP. We FOOTMODULEMIDCLAMP ��' ��e L-FOOTZr �►!L! � RACKING RAIL � STANDARD RAIL ice' ik FLASHING ���--- FLASHING r--- - r r 1 1 I 1 1111 I�Ir` 'iJ I / 1 L >4 ritill111.----1--1111 O L- -J f1 L--7Ci-J L-C(7�' 11 + 4" \ // \\ t t 48" MAXIMUM, BETWEEN ATTACHMENTS A MOUNTING PLAN VIEW(PORTRAIT) r MOUNTING DETAIL PV-8 SCALE: 1"= 1'-6" PV-8 SCALE: 1"=2'-0" 5.25" O 011, ____, ,- .0 ___„--fai„.1 to,4, ., \ . ,.—,e4 .:..------ ------ ,\\ ....____,,,___, _... .„,..„.„,,,„:„0..„-„-....,,,... osoo\Ack°°.. .__ OOM,...-. • ®® 'Oako. RAFTER OR TRUSS 24" ON CENTER 4,4 B MOUNTING METHOD PV-8 SCALE: 1"=2'-0" ELECTRICAL SPECIFICATIONS 370 / 375 380 f Test Conditions STC NOCT , STC NOCT STC NOCT Module Power(Pmax) Wp 370 277.78 375 282.05 380 284.6 Maximum power voltage(Vpmax) V 38.34 35.90 38.61 36.15 38.88 36.41 Maximum power current(Ipmax) A 9.69 7.74 9.77 7.80 9.79 7.82 Open circuit voltage(Voc) V 44.76 42.01 44.94 42.18 45.13 42.36 Short circuit current(Isc) A 10.33 8.32 il, 10.41 8.39 10.50 8.46 Module efficiency % 20.8 19.5 II 21.1 19.8 21.4 20.0 Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp oto+10 Measurement conditions:SIC 1000 W/m2•AM 1.5•Temperature 25°C•NOCT 800 W/m'•AM 1.5.Measurement uncertainty 5 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 19.0±0.2 kg 41.9±0.4 lbs Dimensions(H x L x D) 1795 mm x 990 mm x 38 mm 70.67 in x 39.98 in x 1.5 in Maximum surface load(wind/snow)* 4000 Pa rear load/5400 Pa front load 83.5/112.8 lb/ft^2 Hail impact resistance 0 25 mm at 83 km/h 01inat51.6mph Cells 66 high efficiency back contact 66 high efficiency back contact mono-PERC c-Si cells mono-PERC c-Si cells Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM anti-reflective coating DSM anti-reflective coating Cables and connectors(refer to installation manual) 1200 mm 0 5.7 mm,MC4 from Staubli 47.24 in,0 0.22 in,MC4 fromtaubli Multilayer,integrated insulation film and electrically conductive backsheet,superior hydrolysis and UV resistance,fluorine- Backsheet free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IP67 rated TEMPERATURE RATINGS WARRANTIES - ,,, '. Temperature Coefficient lsc +0.046%/°C Module product workmanship warranty 25 years'* Temperature Coefficient Voc -0.279%/°C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.377%/°C >_97.1%end 1st yr NOCT(±2°C) 43.5°C 0 91.6%end 12th yr 0 85.1%end 25th yr Operating temperature -40/+85°C >_82.6%end 30thyr CERTIFICATIONS SHIPPING SPECS ULC ORD C1703,UL1703,CEC listed***,UL 61215-1/-1-1/-2,UL 61730-1/-2, Modules Per Pallet: 26 or26(California) Product IEC 61215-1/-1-1/-2***.I EC 61730-1/-2***,CSA C22.2#61730-1/-2,IEC 62716 Ammonia Corrosion;1EC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 1 Pallets Per Truck 34 or32(California) Factory 1509001:2015 Modules Per Truck 884 or 832(California) * A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com *** Certification anticipated January 2021. „•, i SILFAB SOLAR INC. c I - N l< 1200mm[7.87"] �� 800 Cornwall Ave o o m Bellingham WA 98225 USA T +1360.569.4733 info@silfabsolaccom _ SILFABSOLAR.COM A W _ -I .. i ..r o 240 Courtneypark Drive East v0 LTco O E Mississauga ON L5T 2Y3 Canada CY 0 a £ 122mm 4.80" T +1905.255.2501 3m co '' �+ F +1905.696.0267 vo W .3 B a rE _.� E Zr'''i 26mm[1.02"] 1 _„.:___I]J U o I_ Silfab-SIL-370/375/380-BK-20201020 mm - -- -} No reproduction of any kind is allowed.Data and information is subject to modifications without notice.©Silfab 2020. Cable Length 1200mm[47.24"] F� PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads °K _ o o - �l 60mm[2.36"1 ,I 4- 447.5mm[17.62"] x 900mm[35.43"] x< 447.5mm 117.62"1 , 1795mm[70.67"] fx, - Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready p Enphase IQ 7 Micro" and Enphase IQ 7+ Micro'M IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery", and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install " • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) -- III Productive and Reliable 7 — • Optimized for high powered 60-cell and 72-cell*modules • c1�; • More than a million hours of testing I • Class II double-insulated enclosure \�-~., to = • UL listed - e ENPHASE. -Qi _, IQ t� Smart Grid Ready ' • '' • Complies with advanced grid support,voltage and 1 "' Wili 5a 'N frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) (11;1) *The IQ 7+Micro is required to support 72-cell modules. CERTIFIED SAFETY US CA E341165 EN PHASE To learn more about Enphase offerings,visit enphase.com a , • Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 -PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com e EN P H A S E 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc 2018-05-24 Data Sheet Enphase Networking Enphase The Enphase IQ Combiner-i- " with Enphase IQ Envoy" consolidates interconnection IQ Combiner+ equipment into a single enclosure and (X-IQ-AM1-240-2) streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart . m m=: • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet,or cellular • Provides production metering and optional • — z• ft t consumption monitoring • Supports installation of the �;M l Enphase Q AggregatorTm see Simple It f , p • Eaton BR series panelboard interior mot, `y-w.--- • Up to four 2-pole branch circuits for 240 VAC plug-in breakers(not included) t • 80 A total PV or storage branch circuits } — • Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty • UL listed UL LISTED EN PHASE To learn more about Enphase offerings,visit enphase.com �./ Enphase IQ Combiner+ MODEL NUMBER IQ Combiner+X-IQ-AM1-240-2 IQ Combiner+with Enphase IQ Envoy'for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES(order separately) Enphase Mobile Connect' CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1 (4G LTE CAT-M1/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring CT CT-200-SPLIT Split core current transformers enable whole home consumption metering*(+/-2.5%). Circuit Breakers BRK-15A-2-240 Breaker,2 pole,15A,Eaton BR215 BRK-20A-2-240 Breaker,2 pole,20A,Eaton BR220 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 240 VAC,60 HZ Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80 A(any combination) Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD) 49.3 x 46.5 x 16.0 cm(19.4"x 18.3"x 6.3") Weight 7.5 kg(16.5 Ibs) Ambient temperature range -40°C to+46°C(-40°to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 3 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable-not included Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G)(not included) COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 916 CAN/CSA C22.2 No.61010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com ©2018 Enphase Energy All rights reserved All trademarks or brands In this document are registered by their respective owner EN P H A S E 2018-05-02 \,/ F1 l Y ri A SUNM INSTALLATION MADE EZ & EZR1 EZ . ********. EZR t SunModo's best-selling EZ Roof Mount is the industry standard for PV system The EZ & EZR Advantage mounting on any composite ✓ Leak-proof design protects shingle roof. sealing points from elements. ✓ ICC Certified for both rafter and Now, SunModo introduces a decking solution. smaller footprint, EZR Roof Mount flashing, where truss ✓ Exceptional resistance to corrosion and wear. anchoring can be assured, embossed design minimizes ✓ A wide variety of L-feet and standoffs available. bending, and only one tool is needed. •/ Surprisingly easy to install! Key Features of EZ and EZR SUNM•Do 1 I I 1 I I , I I MODEL ; EZ Mount ; EZR Mount 0 1 I I Raised teardrop design diverts water from the '"11(roof penetration. , I , I 1 360-degree L foot positioning, serrated L foot on both sides for rail mounting. I 1 A wide variety of L-feet and standoffs available. '141( , 1 , 1 , 1 1 Versatile mounting option includes direct-to- decking for easy installation. Stamped emboss features stiffen the flashing to minimize bending. '14( , I I m. _ Only one tool is needed. 1 1 , 1 1 Technical Data Application Composite shingle Material High grade aluminum, 304 stainless steel hardware Finish Clear anodized, silver or black powder coated Flashing Size EZ Roof Mount: 10.00 x 12.48 x 0.04 inches EZR Roof Mount: 8.00 x 11 .38 x 0.03 inches Roof Attachment EZ Roof Mount: Rafter and decking EZR Roof Mount: Rafter only Structural Integrity IBC and IRC compliant Warranty 20 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com