Plans s ilk
r
Plot RECEIVED
4.
A Ski. 7 fi
;ITY OF TIGARU
53' iUILDING DIVISION
LIABILITY 105' I
The City of Tigard and its Home�orroloyees shall not be , o
resporsible for discrepancies #�, o,
, v�r- may appear herein. :dr
Iso
Main Panel
y. -0
44
Approved p ns g�* �� Utility Meter
2ha!I be on ob te. cvco Combiner
CITY OF TIGARD
VIEWED F0110DE COMPLIANCE
.4LI ITY OF PERMIT
o THE ISSUANCE OF A PERMIT Approved: [
BASED ON CONSTRUCTION OTC: [ I `
I_?OCUMENTS AND OTHER Permit #• y1/�,�j��,OZ1 -
Do I ZZ
DATA SHALL NOT PREVENT lsg�� t, `
x,J -�� Ck
THE CODE OFFICIAL FROM Address:ss:
I=OUIRING THE CORRECTION Suite #:
OP ERRORS. ORSC 105.4 By: prlr Date: cyhp)2I
Spans Elevation >_12"Section 3111.4.8.1
<18" Section 3111.5.3.5
Weight of solar < 4.5 Ib/sgft •
Spans comply with 2308.7.2 OFFICE COPY 18°
Engineered Trusses
4:12, single layer comp roof 1'
Ground to eve Ground to peak
Page 1 of 3
Job: Address:
PNW631 Dan Sorden
Rev: 15800 SW Highland Court
AM Tigard, OR 97224
PROSTAT ELECTRIC & SOLAR
4, Detail
>_12"Section 3111.4.8.1 (ridge)
0
0 0
suney:2 suney:
0 0
0
0 70.67„
39.9"J
suney:1
0
ti
Solar Array Coverage: Suneye Legend (degrees):
Solar Array sqft = 333 1. Tilt = 18 Azimuth = 225
Roof Surface sqft = 2870 2. Tilt = 18 Azimuth = 225
Solar Array covers 12% of roof surface 3. Tilt = 18 Azimuth = 225
Solar Array Setbacks:
>_12 along all horizontal ridges per Section 3111.4.8.1
Page 2 of 3
Job: Address:
PNW631 Dan Sorden
Solar Array Attachments: Solar racking attachments per Rev: 15800 SW Highland Court
3111.3.5.3.3 24" OC within 3' of edge hip eve or ridge, 48" AM Tigard, OR 97224
OC elsewhere
PROSTAT ELECTRIC & SOLAR
Comp Roof
.
2x framing Attachments spaced so that
24" Max on Center no point load exceeds 50 psf
Solar Pane I I I
4.5PSF max
II I 11111
Panel connecte
to rails with 1 connector
for each 8 Sq feet or less i omm i nnisi
per rack manufacturer's specs
\■■I■■I■ II■•■•IIIU•
Aluminum Rails to alternates I
roof framing 4' OC max.
Two rails per min. per panel
mg
Panels 39.9" X
70.6" aprox.
2X joist/truss to meet
Oregon Solar code span
requirements 18"
Max
Min 16"SS lag embedded 2"min
center of framing member 2 Layers or less
of roof material
lashed and sealed
roof penetration
Racking Details:
Manufacturer = Iron Ridge Page 3 of 3
Model = XR100 Job: Address:
PNW631 Dan Sorden
Attachment Details: 15800 SW Highland Court
Manufacturer = Iron Ridge Rev:
Model = FlashFoot2 AM Tigard, OR 97224
PROSTAT ELECTRIC & SOLAR