Plans
WIRE CONDUCTOR NEUTRAL GROUND RACEWAY OUTPUT O UT MIN. WIRE DERATE CALCULATION UT DIST. VOLTAGE CONDUIT s TAG QTY.SIZE&TYPE QTY.SIZE&TYPE QTY.SIZE&TYPE SIZE&TYPE CURRENT OUTPUT OCPD W RE AMBIENT #OF FINAL (FT) DROP% FILL% _ _ CURRENT RATING TEMP. COND. AMPACITY Ifs AC.1 (2)#10 AWG THWN-2 N/A (1)#12 AWG THWN-2 1/2"EMT CONDUIT 15.73A 19.66A 20A 35A x0.96 x 1 =33.60A 40 FT 0.65% 17.63% AC.2 (2)#10 AWG THWN-2 (1)#10 AWG THWN-2 (1)#12 AWG THWN-2 1/2"EMT CONDUIT 15.73A 19.66A 20A 35A x0.96 x 1 =33.60A 10 FT 0.16% 24.33% PV MODULES MICROINVERTERS AC DISCONNECT MAIN SERVICE PANEL AMBIENT TEMPERATURE INFORMATION (13)Panasonic EVPV360K (13)Enphase IQ7PLUS-72-2-US 30A non-fused AC Disconnect Existing 200A MSP,120/240V Extreme Min.Temp -6°C Power at STC:360W Max Output Current:1.21A Utility:Portland General Electric Ambient Temp: 32°C l VED Max Number per Branch Circuit:13 Interconnection:Breaker VOLTAGE DROP INFORMATION a Main Breaker De-Rated:No Internal Voltage Drop: 0.24% .,_.£' .ram Power Control System:NIA AC Voltage Drop: 0.81% Total System Voltage Drop: 1.05% MAY 4 VALIDITY OF PERMIT 202 2 THE ISSUANCE OF A PERMIT ,aI i Y OF TIGARD BASED ON CONSTRUCTION Approved a UILDING DIVISION DOCUMENTS AND OTHER 415l be aCijob site. DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. ORSC 105.4 MMuAIIpN EXISTING WIRE H / ��—�7 B IQ COMBINER 3 ' UTILITY METER 1 STRING OF 13 MICROINVERTERS CONNECTED IN PARALLEL IQ GATEWAY AC DISCONNECTS E 0 3 e0 1 MICROINVERTER PER MODULE I——— (N12^oA /� — �(N SA �o y '—' ` GROUNDING _ ELECTRODE JUNCTION BOX i(N oA o OD Oi MAIN SERVICE U PANEL 1 —••— 13 .i o o—o 0—XDI ©0© MANUFACTURERS Q CABLE W/#6 BARE COPPER GROUND OFFICE COPY CITY OF TIGARD REVIEWED FO1 'ODE COMPLIANCE Approved: [ ✓] OTC: [ l Permit#: IY\S 1 2022 DO (3 G.Address: 15(19 p SW —oab II c4---- Saute #: By: Date: [ ZZ Sun SOLAR PROJECT NAME SITE ADDRESS DATE DEBORD,KATHLEEN 15990 SW BRENTWOOD CT 4-19-2022 SINGLE LINE TIGARD,OR 97224 DIAGRAM 421 C St,Unit 5A TEL.(360)313-7190 Washougal,WA 98671 CCB(OR):198787 SCALE:NTS 14 NEC PV LABELING REQUIREMENTS STICKERS PLACARDS 0 NEC 690.56(B),705.10,705.12 0 NEC 690.13(B),690.54(PV AC DISCONNECT) WARNING DUAL POWER SOURCE PHOTOVOLTAIC AC DISCONNECT SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT 15.7 A NOMINAL OPERATING AC VOLTAGE 240 V NEC 705.12(B)(3)(3)(C) WARNING! THIS EQUIPMENT IS FED BY MULTIPLE SOURCES 0 SYSTEM SPECS TOTAL RATING OF ALL OVERCURRENT DEVICES, PV SYSTEM CHARACTERISTICS EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, 4.68 KW SOLAR ELECTRIC SYSTEM SHALL NOT EXCEED AMPACITY OF BUSBAR 13 PANASONIC EVPV360K 360W SOLAR MODULES 13 ENPHASE IQ7PLUS-72-2-US MICROINVERTERS NEC 705.12(B)(3)(2),690.13(B),690.54 WARNING!POWER SOURCE OUTPUT CONNECTION- DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC0 690.12,690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN OD NEC 690.12,690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM TURN RAPID 0 NEC 690.13(B),690.54 SHUTDOWN SWITCH mm�� TO THE"OFF" PHOTOVOLTAIC AC DISCONNECT POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY RAPID SHUTDOWN SWITCH Sun SOLAR PROJECT NAME SITE ADDRESS DATE LABELING DEBORD,KATHLEEN 15990 SW BRENTWOOD CT 4-19-2022 PER NEC 2020 TIGARD,OR 97224 421 C St,Untt 5A TEL.(360)313-7190 Washougal,WA 98671 CCB(OR)198787 PROJECT INFORMATION PROJECT NOTES OWNER DEBORD RESIDENCE 1.PV SYSTEMS AND SUPPORTING STRUCTURE SHALL EXCEPTION 1.2:WHERE THE SOLAR ARRAY EXCEEDS 25% 15990 SW BRENTWOOD CT COMPLY WITH REQUIREMENTS OF 2014 OREGON AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF TIGARD,OR 97224 STRUCTURAL SPECIALTY CODE(SECTION 3111) THE STRUCTURE, A MINIMUM OF ONE 36" (503)201-3885 2. 3111.3.2-PV RACKING AND ATTACHMENTS SHALL BE UL UNOBSTRUCTED PATHWAY SHALL BE PROVIDED IN 1703 CERTIFIED. ADDITION TO A MINIMUM 12"UNOBSTRUCTED PATHWAY BUILDING SINGLE FAMILY 3.3111.3.4-PV SYSTEM SHALL HAVE A FIRE ALONG EA.SIDE OF ANY HORIZONTAL RIDGE. DATA RESIDENTIAL CLASSIFICATION THAT IS EQUAL TO OR GREATER THAN 6.ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED THE ROOF ASSEMBLY REQUIRED BY OSSC SECTION WOOD CONSTRUCTION WITH 2X4 PRE-MANUFACTURED APPLICABLE 2019 OREGON STRUCTURAL SPECIALTY 1505.1. ENGINEERED TRUSSES AT 24" O.C. REFER TO CODES CODE(2019 OSSC 101) 4. 3111.4.3-3111.4.7-PV LAYOUT SHALL NOT RESTRICT ALLOWABLE SPAN REQUIREMENT IN TABLE 305.4.1. EGRESS, LIGHT VENTILATION, OR ROOF DRAINAGE 7. 3111.4.8.5.1-DISCONNECTS,J-BOXES,COMBINER BOXES SYSTEM PANASONIC 360W REQUIREMENTS. OR GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED 13 MODULES 5. 3111.4.8.1-GENERAL PATHWAY REQUIREMENTS:ALL PV PATHWAY OR CUTOUT. 13 X 380W=4.68 kW INSTALLATIONS SHALL INCLUDE A 36 INCH WIDE 8. 3111.5.3.1-TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 13 ENPHASE IQ7PLUS-72-2-US MICROINVERTERS PATHWAY MAINTAINED ALONG THREE SIDES OF THE 4.5 PSF. PV MODULES AND RACKING SHALL BE SOLAR ROOF. DIRECTLY ATTACHED TO ROOF FRAMINGS AS SHOWN IN MODULE PANASONIC EVPV360K EXCEPTION 1:ON STRUCTURES WITH A PV ARRAY AREA OF CONNECTION DETAIL#2. ATTACHMENT SPACING WILL SPECS (L)67.75"X(W)4D.D"X(H)1.6" 1,000 SF OR LESS INSTALLED ON A ROOF WITH A SLOPE BE 48" O.C. MAX, AND WHEN ATTACHMENT LOCATED WEIGHT=42 LBS THAT EXCEEDS 2:12 AND WITH AN INTERSECTING WITHIN 3'OF ROOF EDGE,HIP, EAVE, RIDGE SHALL BE OMBINED WEIGHT OF MODULES AND ADJACENT ROOF AND WHERE NO SECTION IS LARGER 24"O.C.MAX. CRACKING E O =< 5 PSF. THAN 150 FEET MEASURED IN LENGTH OR WIDTH. 9.3111.5.4- MAX MODULE HEIGHT<18"OFF ROOF EXCEPTION 1.1:WHERE PV ARRAY DOES NOT EXCEED 25% SURFACE. CONTRACTOR SUNBRIDGE SOLAR AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF 421 C ST,UNIT 5A A STRUCTURE, A MINIMUM OF 12" UNOBSTRUCTED WASHOUGAL,WA 98671 PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF CONTACT:GARRET LITTLE ANY HORIZONTAL RIDGE. PHONE:(360)313-7190 ROOF SPECS ASPHALT COMPOSITION SHINGLE ROOF 2X4 PRE-MANUFACTURED ENGINEERED TRUSSES SPACED©24"O.C. TILT:25° AZIMUTH:270° AREA OF ROOF(PLAN VIEW)=2,552 SF AREA OF NEW SOLAR ARRAY=245 SF (ARRAY< 25%OF ROOF AREA) ELECTRICAL SERVICE VOLTAGE:240V SERVICE SERVICE AMP RATING:200A MAIN DISCONNECT TYPE:BREAKER INTERCONNECTION TYPE:BREAKER PROVIDER:PORTLAND GENERAL ELECTRIC MAIN PANEL BRAND:CUTLER-HAMMER PROJECT NAME SITE ADDRESS DATE SHEET Al DEBORD,KATHLEEN 15990 SW BRENTWOOD CT 4-19-2022 TIGARD,OR 97224 COVER 421 C St,UM 5A TEL(360)313-7190 Washougal,WA 98671 CCB(OR):198787 NOTES: -SUNEYE SHOTS S1 AND S2 WERE COLLECTED IN THE SPECIFIED LOCATIONS. -MICROINVERTERS ARE LOCATED ON UNDERSIDE OF EACH MODULE AND ARE CONNECTED TO CONTINUOUS SUPPORT RAIL. -LINES DO NOT REFLECT ACTUAL PROPERTY LINES. -TILT:25* V ~ Ell ❑ D ❑ D 0 ...NUM 00 M`- D 0 0 ❑ W 0 e 0 CM i 0 CC CC m 0 DRIVEWAY ❑ ❑ 0 0 N ❑ o ./"! UTILITY METER UTILITY DISCONNECT ELECTRICAL PANEL IQ COMBINER BOX fI kM I v4 .11 SCALE:1/16"=1'-0" � ` ./I 0' 8' 16' 32' PROJECT NAME SITE ADDRESS DATE SHEET A2 DEBORD,KATHLEEN 15990 SW BRENTWOOD CT 4-19-2022 421 C St,una 5A TEL.(sso)313-7190 TIGARD,OR 97224 SITE PLAN Washougal.WA 98671 CCB(OR),198787 (E)2X4 PRE-MANUFACTURED p R MMANU=. PER MANUF. ENGINEERED TRUSSES$24"O. . ER MAT U♦�. II \ —r51-0" (N)SOLAR ARRAY I __ (N)ATTACHMENT _ RAILS,TYP. I O O I O O .---_ _....._. -_.� ❑ — j 1 I I 9 0 0 0 O O O 0 0 - (N)CONNECTION V U V -—---- -- - TO ROOF TRUSS, TYP. II I O O O O I O IW 0 -- �. _r __ , 1.0--- ----- 34'_9" S - - ID 1 I i w ! I I I i I 0 0 I I I I I — cp— --_ ---- _ LL i I I I❑ i I I I �i IO — _ -_. - reI I I 0 - - 6,-2„ I I i I i E3 — ---- _ __ - 1 ! I I I 1 __--- I i I ill I ' ��� 4 k'S‘\\NOTE: t1 '1 DIMENSIONS ARE REAL v`o! ROOF DIMENSIONS (NOT ABOVE VIEW). SCALE:1/8"=1-0" PROJECT NAME SITE ADDRESS DATE SHEET A3 DEBORD,KATHLEEN 15990 SW BRENTWOOD CT 4-19-2022 421 C S,Uni15A TEL.(380)3/37190 TIGARD,OR 97224 ROOF PLAN Washougal,WA 98671 COB(OR):198787 2. CONNECTION DETAIL SCALE NTS SOLAR COLLECTOR MODULE DIMENSION MODULE(4 PSF, /r VARIES I ! MAX) 1. ROOF SECTION SCALE:NTS o. ' SEC --' L - r CONNECT SOLAR ii i i I MODULE TO RAILS WITH 1 CONNECTOR FOR EACH 8.SO FL ---- - ---"- --- - - (E)2X4 PRE-MANUFACTURED OR LESS OF MODULE ENGINEERED TRUSSES @ 24"O.C. (N)SOLAR MODULE SURFACE ARRAY AND ATTACHMENT SYSTEM — TO EXISTING ROOF CORROSION RESISTANT + TRUSS METAL RAIL ANCHOR TO II ALTERNATE ROOF FRAMING ' 48"MAX.ON CENTER PER �•.�_� ��. BUILDING SECTION A-A TYPICAL . I I HEIGHT 30 PROVIDE A MINIMUM OF 2 I 51ooF FRAMING sPAaNG� �_ RAILS PER MODULE. L�@ 24"MAX ON CANTER _... ihihhk 3. CONNECTION DETAIL SCALE:NTS SECTION CUT 1 SOLAR MODULE P/- IRONRIDGE XR10 CONTINUOUS SUPPORT RAIL AND CONNECTION • POST BY RAIL MANUFACTURER ./ • • • ASPHALT COMPOSITION IRONRIDGE FLASHFOOT2 FOOTING. SHINGLES ROOFING .' 5/16"X4"LAG BOLT AT EA.FTG. ROOF RAFTER©24"MAX. O.C,TYP. PROJECT NAME SITE ADDRESS DATE SHEET A4 DEBORD,KATHLEEN 15990 SW BRENTWOOD CT 4-19-2022 TIGARD,OR 97224 SECTION CUTS& 421 C St Und 5A TEL.(360)313-7190 Washougal,WA 98671 GCB(OR)198787 CONNECTION DETAILS Data Sheet Enphase Microinverters Region: AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Micro' IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery", and the Enphase Enlighten'M monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install ,; • Lightweight and simple • Faster installation with improved,lighter two-wire cabling - -- • Built-in rapid shutdown compliant(NEC 2014&2017) Ii Productive and Reliable . - "`"' • Optimized for high powered 60-cell and 72-cell*modules imooS _ • More than a million hours of testing ,� • Class II double-insulated enclosure "'r -, - • UL listed eENPHASE it .'i..® 4. IQ7 1 W IN w Smart Grid Ready Ell 1.li II. �� • Complies with advanced grid support,voltage and m frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 41) *The IQ 7+Micro is required to support 72-cell modules. CERTIFIED • SAFETY us CA E341165 ENPHASE To learn more about Enphase offerings,visit enphase.com Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS 72-2 US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0' 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https:/Lenphase.com/en-us/su_pportL odule_compatibil y.. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com e EN P H A S E C 2019 I npliase Energy All rights reserved All trademarks of brands used are the properly of Enphase Energy,Inc 2019 3-26 EverVoft EVERVOLT"SOLAR MODULE SERIES Panasonic 370W / 360W TRUST. BUILT IN. The Panasonic Advantage Higher Module Efficiency �. Superior module efficiency of 21.2%and 20.6%, MI respectively, allows maximum power production with less roof space.With one of the industry's -_ lowest annual degradation rates, power output of at least 92% is guaranteed after 25 years. ALLGuard and TripleGuard 25-Year Warranty' A long-term warranty is only as reliable as theNei company behind it.AllGuard and TripleGuard -- - 25-year warranties cover EverVolt panels for performance, product, parts and labor for 25 years.Whether in year three or year 25,your Panasonic warranty will be there when you need it. `' High Efficiency in High Temperatures Produce more energy throughout the day even '" \` on the hottest days in the warmest climates. EverVolt solar panels outperform others when temperatures rise due to our industry-leading 0.26%/°C temperature coefficient. friant Heterojunction Cell Technology 0001 Half-cut cells with heterojunction technology ..-1-U-r minimizes electron loss, maximizes conversion efficiency, and produces considerably higher power output over conventional panels. ALLGUARD TRIPLE GUARD Durability&Quality Assurance WARRANTY WARRANTY C; N-type cells result in minimal Low Induced ,),, ��r J�r�t� • /,,� degradation (LID)and Potential Induced 5 YEARS r.r degradation (PID),which supports reliabilityand * PRODUCT g PP ol.� * PERFORMANCE longevity.As a solar pioneer for over 40 years, * LABOR Panasonic EverVolt solar panels are backed by > innovation,experience and a brand you can trust. 0 Improved Performance When Shaded Continuous power production in shaded areas for greater energy yields and output. More sunlight absorption means more clean power to your home. Panasonic Life Solutions Company of America Alt Rights Reserved©2021 COPYRIGHT Panasonic Corporation Panasonic Two Riverfront Plaza,Newark,NJ 07102 Specifications are subject to change without notice panasonicHIT�°us.panasonic.com RS2001040S-r27 na,panasonic.com/us/solar EverVo t EVERVOLT°°SOLAR MODULE SERIES Panasonic 370W/ 360W TRUST. BUILT IN. k EL[Ci RICAL SPECIFICATIONS PERFORMANCE WARRANTY Model EVPV370 EVPV360 100% Rated Power IPmaX1 370W 360W 98%' Maximum Power Voltage(Vpml 37.4V 36.7V 9:% Maximum Power Current Rpm) 9.90A 9.82A 90% More power Open Circuit Voltage(Vocl 44.1V 43.9V over 25 years Short Circuit Current hsc) 10 55A 10.49A 80% ,80% Temperature Coefficient(Pmaxl -0.26%/°C Temperature Coefficient IVocl -0.24%/°C Temperature Coefficient(tscl i 0.04%/°C 70% 0 5 10 15 20 25 NOCT 44°C 1±2°C1 ■Panasonic ■Conventional CEC PTC Rating 351.8W I 342.1W `-- J Module Efficiency 21.2% 20.6% DIMENSIONS Maximum System Voltage 1000V 47 75 0 t 11721 2 51 Maximum Series Fuse 25 A -. 1.1[281 31.518021 . 17.914551 10W Watt Class Sorting 0/+ t ti i - + -'/ ❑ -- " 39(10001 v MECHANICAL SPECIFICATIONS o Junction Box 3-part,3 bypass diodes,IP67 rated o in accordance with UL 3730 0 0.43t0.008 Connector Type Staubli MC4 PV-KBT4/KST414 mm°I o «[1+0.21 { in accordance with UL 6703 IP68 only when connected e Cable Size/T e 4mm2 solar cable,1.0m+1.2m v "-+ —V Type in accordance with UL 4703 0.81±0.02 i` ;- Cable , Max Snow Load 1+12 146 psf 17000 Pal' F Max Wind Load(-)2 83 psf 14000 Pal+ �_ 147(12001 a Dimensions LxWxH 67.8 x 40.0 x L2 in 11721 x 1016 x 30 mm) o 1 it e Weight 43.0 tbs(19.5 kgl 1 i� 4.5m0.t2162L3] 70x42x48in . - 1.81451 0.9122.51 Y Pallet Dimensions LxWxHI 1.181301 Quantity per Pallet/ 1 33 pcs./1512 lbs.(686 kg) Measurements in in lmml Pallet Weight Quantity per 40'Container 858 pcs +Test Load Design Load should be multiplied by two thirds. DEPENDENCE ON IRRADIANCE OPERATING CONDITIONS AND SAFETY RATINGS UL61730 to; \ - Certifications IEC61215-2:2016[Hailstone 35mm1 Fire Type 2 IUL 617301 Operating Temperature -40°F to 185°F I-40°C to 85°CI L6 T 25'Yrs Workmanship and Limited Warranty Power Output ILinearl— 4 Power Output in Year 1 98% 2 Annual Degradation 0.25% 0 1-. ----------'\\\ Power Output in Year 25 92% 0 10 20 30 40 50 Voltage[VI NOTE Values at standard test conditionstSTC:air mass AM1.5 irradiance 1000W/m2,temperature 25°Cl. Reference data for model EVPV360 •Maximum power at delivery For guarantee conditions,please check our guarantee document. Cell temperature:77°F 125"CI •*Installation need to be registered through our website www.panasonicusahitwarrantycom within 60 days in order to receive twenty-five 1251 year Product workmanship.Otherwise,Product Workmanship will be only fifteen 1151 years. Equipment must be installed by a Panasonic Authorized,Premium,or Elite installer and registered at www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five 1251 year AllGuard andat* Cil us TripleGuard warranty. 'Refer to installation manual for detailed mechanical loading information Intertek .•'1st year 98%.after 2nd year 0.25%annual degradation to year 25. NOTE:Specifications and information above may change without notice. Z' CAUTION!Please read the installation manual carefully before using the products. Used electrical and electronic products must not be mixed with general household waste.For proper treatment.recovery and recycling of old products,please take them to applicable collection points in accordance with your national legislation. a Panasonic Life Solutions Company of America All Rights Reserved 71 2021 COPYRIGHT Panasonic Corporation /� Two Rlverfront Plaza,Newark,NJ 07102 Specilicanons are subject to change witnoutnolice Panasonic panasonicH]T@us panasonic.com RS200104D5 r27 na.panasonic.com/us/solar