Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
OFFICE COPY . CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: GENERAL SPECS;VICINITY&SITE PLA I [) 1 Lr CITY OF TIGARD UL 7 2022 GENERAL SPECIFICATIONS REVIEWED FO ODE COMPLIANCE N ROOF SPECIFICATIONS, x1�1 01—Y OF TIGARD 30.3°PITCH T COMPOSITION ISSUE FOR PERMIT T Approved: [ ] s E3JILDING DIVISION OTC: ` ARRAY ROOF COVERAGE 372 SQ.FTJ 2,089 SOFT.- 17.8% (04-04-2022) cc ARRAY TO BE INSTALLED ON EXISTING Il Permit#: (� (y��[7�)7,tI/ VC/(/ l-2--- BUILDING O �� -�...` ` Q J,/� n SYSTEM SPECS: DRAWING LIST LL SUN Address: OZ �rJ ���� • �� 6.UKWDGMYMTEM D M0)HANI: SHEET# TITLE CO (20)HANWHA Q CELL Q.PEAK DUO BLK • MLG10+400 Suite #: 0 '.,,. - ergy� INVERER/Sl: PV7.0 GENERAL SPECIFICATIONS;VICINITY 8 SITE PLANS 111H I f i/� (20) E IQ7A-72-2-US • `-• Date: /v_ (1COMBINERENPASE-X: PV2.0 ARRAY DESIGN-LAYOUT .7 (7)ENPHASE-%-IQ-AMt-200.3-ES wwwsu nlighisolar.com ARRAY SPECIFICATIONS: PV3.0 PHOTOVOLTAIC DETAILS 8 ONE LINE DIAGRAM • 541-322-1 9)0 ARRAY TILT = 30.3' ARRAY ORIENTATION = 139.5° PV4.0 SITE ELEVATIONS 8 PANEL SPECIFICATIONS ! 'SUNLIGHT SOLAR ENERGY.INC. AVERAGE SOLAR RESOURCE: 150 NE HAWTHORNE AVE. !., TOF = 97% BEND,OR 97701 �� PV5.0 ELECTRICAL SPECIFICATIONSTSRF= 95.49% II CCP*158922 ''•� PV5.1 STRUCTURAL SPECIFICATIONS • G � T•.5 — UTILITY METER 8 PV AC DISCONNECT/ PV6.0 PLACARD DETAIL I W RAPID SHUTDOWN INITIATION SWITCH CD To (EXTERIOR GARAGE-EAST WALL) PV7,0 MODULE SPECIFICATIONS * I ti 13� ` HOUSE PANEL 8 IQ C-EAST ER PANEL • O (INTERIOR GARAGE-EAST WALL) PV7.7 MICROINVERTER SPECIFICATIONS-107A Approved plans PV72 Q COMBINER 3SPECIFICATIONS * N shall be on job site. '3 RACKING SPECIFICATIONS-ULTRA RAII.COMP KIT •- O a O — RIDGE,MAX HEIGHT 43' a- 3'd' 4°4 PV7.4 RACKING SPECIFICATIONS-ULTRA RAIL • c A, 111141111114- EXTERNAL ROOFTOP CONDUIT V/ C U I1 .....).0_4'.T t PROPERTY LINES V J `.3 II I / O CO / LOWEST TSRF 95.49% r / — ARRAY (20)HANWHA Q CELL-Q.PEAK DUO X BLK ML-G10A 400 MODULES W/ REVISIONS 1.ISSUE FOR PERMIT(OC#22) MICR(20)OINVERTERSENPHASEIQ7A-72-2-US )0e.V VALIDITY OF PERMIT THE ISSUANCE OF A PE''ITj1 RTY DATE DRAWN: 04-04-22 BASED ON CONSTRUCT!• ' TD/SD/SS DOCUMENTS AND OTHER LLB/TS SITE PLAN 41411) DATA SHALL NOT PREVENT . 2 VICINITY MAP SHEET: SCALE:1 =20'-P THE CODE OFFICIAL FROM SCALE:NONE 1.NONE. PVI .0 1 NONE NORTH REQUIRING THE CORRECTION LIABILITY Customer�iSC 105.4 . Customer Signature/Date: . ©2021 The City of Tigard and its employees shall not be responsible for discrepancies which may appear herein. CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: ARRAY DESIGN-LAYOUT HANWHA O CELL- O.PEAK DUO BLK ML-G10.400W 20'-104" 64Y RIDGE �2'� �z,_6„y \ \ 12'MINIMUM PATHWAY ` 1�.� �///////^/7r�1�i///vim//r; 7' r r r r PV-MODULE DETAIL / SCALE:NONE _ ergy - / r r r r \ wwwsunligMS0I0Lcom / 1 r r r r r I r r A 541-322-1910 I r I r r I �.. ` (50)SNAP N RACK ULTRA RAIL l r r ' UR-40 L-FEET 8 FLASHING SUNLIGHT SOLAR ENERGY.INC. I r r\ • 150 NE HAWTHORNE NE AVE. BEND.OR 97701 l r r 1 e r e r i/ r r • r \ CCB#'158922 ARRAY 4 / (20)HANWHA O CELL-O PEAK DUO / r BLK ML-G10.400 MODULES W/ .4.-4 i I i I 1 • (20)(PO ENPHASE 107A MICROINVERTERS a) r ) a)Q , r r r r r r r r r % CCC� / 1 _ -1—,Va) 4 O26_ '\/ ! ! 1 SNAPN RACK ULTRA RAIL N. UR-4O SOLAR RAIL-BLACK N00) ./ r r r r ? V \ r 18 �" % r r C r r r r \ 5)ROOFVENT 0 O r r I . r r r r r r ^ PRE-ENGINEERED TRUSSES ^` // 1 ; r 1 r 1 r 1 I r r r \ 24'O.C.(TYPICAL) 4//, 0 1 r r �'/' r .\ COMP ROOF CO lr r G r a w a w ''``��__r r EXTERNAL ROOFTOP CONDUIT CO (13 r r - •. r . . J d�]W \ ROOFTOP JUNCTION BOX 8 PENETRATION O m I + / ; r . r r r r r r r r 1 TO 10 COMBINER PANEL BELOW II, r r r r r r r r r r . r r % (SEE NOTE#2) r / • I . _, ! I A. 1 1 I I a r 1 \ REVISIONS r LOWEST TSRF 95.49% 1.ISSUE FOR PERMIT(04-04-22) 1'241 A 1 1 1 1 1 1 ' I I I J—. 14I f 1 -i I I M I L l l I l T l J l l lr111 i 1 1 I I I i <1 1 '' r i i l 1), 1 I1 1 1 / I a M.1 1 1,1 1 1 , 1 I \ \ . 1 DATE DRAWN: 04-04-22 ` j\PARTIAL ROOF PLAN-ARRAY DESIGN TD/SD/Ss O SCALE:1/4'-1'-0" ,, LLB/TS J� NOTES: (/,9 1. SEE'ROOF MOUNTING ASSEMBLY DETAIL'ON PV3.0 FOR MOUNTING DETAILS. NORTH SHEET: i,,, 2.PV CONTRACTOR SHALL RUN CONDUIT DOWN EXTERIOR HOUSE EAST WALL TO COMBINER PANEL BELOW. PV2,0 Customer Name(printed): . Customer Signature/Date: . • ©2021 CITY STAMP. PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO.!INCENTIVE:PGE-ETO-ODOE TITLE: PV DETAILS&ONE LINE DIAGRAM rxc(vLI�. PHOTOVOLTAIC MODULE COMPOSITE ROOF '{( ARRAY SHINGLES&VAPOR 'l' (9)HANWHA Q CELL'Q.PEAK DUO BARRIER(BY OTHERS) \ BLK ML-G10+400 8 9)ENPHASE ROOF SHEATHING 8 �111`-- �4 (MICROINVERTIOERS IN PARALLEL) SUBSTRATE N4ihhN�1 • &M" (BY OTHERS) ` I[',V \ U f hu111 �Y SNAPNRACK-UMBRELLA LAG- - Mf ULTRARACK- MC-4 TYPE CONDUCTORS TYPE 3-4'STAINLESS STEEL �(�M iT� ULTRA RAIL UR-40 O MC-4 TYPE CONDUCTORS er '°° -LAG SHALL PENETRATE ROOF �nN (ENPHASE 0 CABLE) (ENPHASE 0 CABLE) FRAMING PENETR PENETRATIONS, MINIMUM. ` -� ARRAY (1)56 BARE EGC IN FREE AIR SEAL SIDES TRATIONS, \ Po�9','^ SNAPNRACK-ULTRA ALL SIDES PER 'y�ry-- FOOT SYSTEM www.sunlightsolor.com MANUFACTURERS _ „419,,-l� — (11)HANWHA ML-G10 qpCELL $LL'O.PEAK DUO RECOMMENDATION. • ` SNAPNRACK-COMP (11)ENPHASE 107A-72-2-US(240V) 9 ` FLASHING 9'x 12' MICRgNVERTERS IN PARALLEL(SEE NOTE#2) ROOFTOP 541-322-1910 • (E)PRE-ENGINEERED TRUSSES JUNCTION BOX SUNLIGHT SOLAR ENERGY,INC. 24'O.C.(TYPICAL) (UNDER MODULE) 150 NE HAWTHORNE AVE. MC-4 TYPE CONDUCTORS MC-4 TYPE CONDUCTORS BEND,OR 97701 (ENPHASE 0 CABLE) (ENPHASE 0 CABLE) CCBIF.158922 (1)56 BARE EGC IN FREE AIR PV-COMPOSITION ROOF MOUNTING ASSEMBLY )4)#10THHWN-2EGC DETAIL (SNAPNRACK-ULTRA RAIL COMP KIT) PRCT CABLE ODUCT(PRODUCTION) IN3/4'EMT a) 5— SCALE:NONE a STING (jlll� ENPHASE � Q K1 COMBINER 3 PANEL TO UTILITY WIFl r EXISTING W/INTEGRATED 10 ENVOY a) c) CONNECTION((��ENV 10A 20A 20A (WWI ENABLED) c N-\ 2P 2P 2P (X-K1-AM1-240-3-E5) 5)) (INTERIOR GARAGE- EAST WALL) Cl) C /L EXISTING O (3)#BTHWN-2 E O FEEDER (1)#10 THWN-2 EGC IN 3/4'EMT O a) C EXISTING PV AC DISCONNECT/RAPID (n U 0 M PGE UTILITY METER 0 SHUTDOWN INITIATION SWITCH' #34 886 502 60A/2P/240V NFSS,NEMA 3R; (EXTERIOR GARAGE- SIEMENS-LNF222R EAST WALL) (EXTERIOR GARAGE-EAST WALL) i A VJ (o 11 EXISTING FEEDER (1)#10 THWN22 EGC CVa) CD K1 IN3/4'EMT IIIIIIIIIIIIIIIII 1` IIIIIIIIIIIIIIIII HANWHAQCELL- O.PEAK DUO BLK - EXISTING 10A IIIIIIIIIIIIIIIIIML-GiM 400WEXISTING SQUARED IIp1111,111111111 M P MAIN SERVICE PANEL IIIIIIIIIIIIIIIII 200A 240H2OV-103W REVISIONS 11111111111III III (INTERIOR GARAGE- 1011111111111111 ��I �� EAST WALL) 1.ISSUE FOR PERMIT(04-04-22) IIIIIIIIIIIIIIIII — — R— 111111IIIIIIIIII,I IIIIIIIIIIIIIII�J 5 6 —, f. () EXISTING#6 GEC TO EXISTING AC ELECTRODE DATE DRAWN: AC NON-FUSED DISCONNECT ENCLOSURE DETAIL o4-04-22 PV MODULE DETAIL (SIEMENS-LNF222R-60A/2P/240V; NEMA 3R) TD/SD/SS ONE LINE DIAGRAM LLB/TS SCALE:NONE SCALE:NONE SCALE:NONE NOTES: SHEET: 1. ALL SHOWN IS NEW AND BY PV CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 2.MI CONTRACTOR STABACENTER FEUD THE MICROINVERTERER BRANCHB BIRCUITRANCH INTO ONE 5 P` ,A .O MICROINVERTER SUB BRANCH CIRCUIT AND ONE 6 MICROINVERTER SUB BRANCH CIRCUIT. V-VS) Customer Name(printed): . Customer Signature/Date: . ©2021 CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: SITE ELEVATIONS&PANEL SPECIFICATIONS M RIDGE,MAX HEIGHT 43' ARRAY //\\ (BLK E. 0+400 MODULEEAK DUO (ON OPPOSITE SIDE OF ROOF) Yos erg is wwws S om,eamaAgo aft mama _ A Q ' 541-322-1910 T ,' ...4 - �•-�"' w� A SUNLIGHT SOLAR ENERGY,INC. r .. - x� '� 'f✓" *._' - 150 NE HAWTHORNE AVE. - �-` `a+ YL_ BEND,OR 97701 �,,�� LOCATION FOR 2P-40A PV , CCM'158922 ;`,ti • '*4"^r_.r- 3 INTERCONNECTION POINT +; "'''R.a�.. AT END OF BUS BAR _ a) ELEVATION-STEET VIEW SERVICE PANEL DETAIL a) O O L O SCALE:NONE �J SCALE:NONE a) O c N- ^cn cmLL E O 7 CC/) V O ccs ELECTRICAL PANEL INFORMATION CO ca I MANUFACTURER SQUARED Q) alBUS AMP RATING(A) 200 A O (� I ��7Ilff SERVICE VOLTAGE N) 240/120 V-10-3W t EXISTING UTILITY METER EXISTING SQUARED j MAIN SERVICE DISCONNECT(A) 200 A MCB / I MAIN SERVICE PANEL j PV AC DISCONNECT/'RAPID REVISIONS `t 200A,240/120V,10,3W -- SHU7DOWNINITWTION SWITCH- /. i� PHOTOVOLTAIC OCPD AMP RATING(A) 40A/2P ECB&BOA NFSS 60A✓2P/240V NFSS;NEMA 3R 1.ISSUE FOR PERMIT(04-04-22) (EXTERIOR GARAGE-EAST WALL)��� NOTES'. - (INTERIOR GARAGE-EAST WALL) _ - 1. NONE DATE DRAWN: r .::,1',. 40 04-04-22 TD/SD/SS LLB/TS /. PV EQUIPMENT-LOCATION -PV EQUIPMENT-LOCATION SCALE:NONE O SERVICE PANEL SPECIFICATIONS SCALE. SHEET: PV4.o Customer Name(printed): . Customer Signature/Date: ©2021 • CITY STAMP: PANEL ORIENTATION: 139.5° 1 ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: ELECTRICAL SPECIFICATIONS SERVICE PANEL RATINGS VOLTAGE RISE-IQ7A MICROINVERTERS TO ROOF-TOP J-BOX SITE TEMPRATURE INFORMATION BUS AMP RATING(A): 200A Q CABLE AND INTERNAL VOLTAGE RISE PORTLAND,OR(ASHRAE) SERVICE VOLTAGE(V): 240/120V-10-3W (PER ENPHASE ENERGY-AC LINE,VOLTAGE CHART©2021) AVERAGE HIGH°C: 26.70°C F,,SUN * . MAIN AMP RATING(A): 200A MCB 240 VAC, 1.3M SPACING,9 MOD.,PORTRAIT ORIENTATION: 0.46%Vrise RECORD LOW°C: -6.40°C t 1, PV OCPD AMP RATING(A): 40A 2P ECB ASHRAE 0.4%HIGH 35.40°C S' ; ° AC AMPACITY&WIRE SIZING-NEC TABLE 310.15 VOLTAGE RISE-ROOF-TOP J-BOX TO COMBINER PANEL ergy"` ARRAY DESIGN (AC)CALCS-ARRAY THRU ROOF-TOP J-BOX TO IQ COMBINER WIRE INFORMATION WIRE LENGTH: 65 ft #OF ARRAYS: 1 www.sunlightsolar.com (INVERTER MAX AC CURRENT)x(#of Modules)x(1.25) WIRE TYPE: #10 THWN-2 #OF SOURCE CIRCUITS: 2 541-322-1910 1.45 x 11 x 1.25= 19.94A WIRE RESISTANCE(from NEC CHAPTER 9,TABLE 8): 0.00124 0/FT #OF PANELS PER SOURCE CIRCUIT: 9,11 WIRE SELECTION IQ 7A FULL LOAD AC CURRENT: 1.45 A SUNLIGHT SOLAR ENERGY,INC. #10 THWN-2 INVERTER RATINGS 150 NE HAWIHORNE AVE. RATED AMPACITY: 30A ADJUSTED VOLTAGE RISE AMPACITY COMPARISON INVERTER MANUFACTURER: ENPHASE BEND,OR 97701 (MPS/INVERTER x x NUMBER OF RA/ENTERS)X(WIRE RESISTANCE x uWAY WIRE LENGTH)/SYSTEM VOLTAGE INVERTER MODEL: IQ7A-72-2-US CCBp:158922 AC AMPACITY vs.RATED WIRE AMPACITY: 19.94<30 (1.45A x 9)x(0.00124 0/FT)x(65 x 2)/240V 0.88%Vrise MAX DC VOLT RATING(V): 58V (AC)CALCS-IQ COMBINER THRU NFSS TO HOUSE PANEL VOLTAGE RISE-COMBINER PANEL THRU NFSS TO HOUSE PANEL MAX POWER @ 40°C(W): 366W �. NOMINAL AC VOLTAGE(V): 240V 0) (INVERTER MAX AC CURRENT)x(#of Modules)x(1.25) WIRE INFORMATION MAX AC CURRENT(A): 1.45A ((1.45 x 9)+(1.45 x 11)]x 1.25= 36.25A WIRE LENGTH: 10 ft PV MODULE RATINGS @ STC: ~O WIRE SELECTION WIRE TYPE: #8 THWN-2 #8 THWN-2 MODULE MANUFACTURER: HANWHA 0 CELL RATED AMPACITY: 40A WIRE RESISTANCE(from NEC CHAPTER 9,TABLE 8): 0.000778 11./FTCD CD MODULE MODEL#: Q.PEAK DUO BLK ML-G10+-400 AMPACITY COMPARISON IQ 7A FULL LOAD AC CURRENT: 1.45 A 10 77A (/3 ,- C3 AC AMPACITY vs.RATED WIRE AMPACITY: 36.25<40 ADJUSTED VOLTAGE RISE OPERATING CURRENT(Imp): y-, Il SHORT-CIRCUIT VOLTAGE T ENT(Vmp): 11.14A7 O ry OUTPUT CIRCUIT(AC)-CONDUIT SIZING- LAMPS'"(1.4S"020)0(0.0 INVERTERS)xrv+IRE RESISTANCE OsnxuWAY WIRE LENGTH)0.19 SYSTEM VriseVOLTAGE OPERATING ITVOLT (Vmp): 37.13V 0 (1.45A x 20)x(0.000778 0/FT)x(10 x 2)1240V 0.19%Wise OPEN-CIRCUIT VOLTAGE(Voc): - 45.30V a E ARRAY ROOFTOP J-BOX TO IQ COMBINER PANEL MAXIMUM POWER(W): 400.0W Vmp TEMP COEFF: -0.34%/°C O Cll 0 NUMBER OF(#10 THWN-2)IN CONDUIT: 4 TOTAL VOLTAGE RISE Voc TEMP COEFF: -0.27%/°C Cl) 0 (4)#10THWN-2+(1)#10EGC MAX FUSE RATING(A): 20A C6 = 4 x 0.0211+1 x 0.0211= 0.106 sq.in. (MICROS TO ROOF-TOP J-BOX)+(ROOF-TOP J-BQX TO IQ COMBINER)+ CONDUIT SELECTION 3/4"EMT (IQ COMBINER THRU NFSS TO HOUSE PANEL) (n PERMITTED AREA FOR OVER 2 WIRES: 0.213 sq.in. (0.46%)+(0.88%)+(0.19%). 1.52%Vrise CN 0) AREA COMPARISON C ) CO WIRE AREA vs.PERMITTED AREA FOR OVER 2 WIRES: 0.106<0.213 OUTPUT CIRCUIT(AC)-CONDUIT SIZING- ~ IQ COMBINER PANEL THRU NFSS TO HOUSE PANEL REVISIONS NUMBER OF(#BTHN-2)IN CONDUIT: 3 W (3)#8 THWN-2+(1)#10 EGC 1.ISSUE FOR PERMIT(06-01-22) 3 x 0.0366+1 x 0.0211= 0.131 sq.in. CONDUIT SELECTION 3/4"EMT PERMITTED AREA FOR OVER 2 WIRES: 0.213 sq.in. AREA COMPARISON I DATE DRAWN: WIRE AREA vs.PERMITTED AREA FOR OVER 2 WIRES: 0.131<0.213 - _ 04-04-22 ° TD/SD/SS LLB/TS/9 SHEET: PV5.0 Customer Name(printed): . Customer Signature/Date: . A ©2021 CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: STRUCTURAL SPECIFICATIONS SUN , STRUCTURAL CALCULATION-SNAP N RACK ULTRA RAIL RACKING SYSTEM PROJECT DATA ••, edgy I. PANEL HOLD DOWN/DESIGN WIND PROJECT NAME- POSS PRESSURE SOLAR MOUNT PANEL DATA BUILDING HEIGHT- 43' www.sunlightsolar.com UPLIFT EXPOSURE(A;B;C OR D)- B 541-322-1910 (20)HANWHA Q CELL-Q.PEAK IMPORTANCE CLASSIFICATION- 2 DUO BLK ML-G 10+400 BASIC WIND SPEED- 95 MPH SUNLIGHTTHERNE Y,INC. T'(21.12)F PER PANEL x(20)PANELS=(422.4) 150 FT'ARRAY 74.0 X 41.1" NENE HA AVE.HAWTHORNE A (36.25)LB/FT'x(422.4)FT'=(15,312)LB WIND UPLIFT 21.12 FP PER PANEL BEND,OR 97701 POTENTIAL MODULE WEIGHT=48.5 LBS. GCB#:158922 HOLD DOWN DISTRIBUTED DEAD LOAD RESULTS a) 339.6 LB WITHDRAW RESISTANCE(1)@(5/16")-4"LAG MODULE WEIGHT=2.3 DESIGN PRESSURE IS THE PRESSURE THAT A PRODUCT W T'/1.81"EMBEDMENT LENGTH. LBS./FP ti 469.0 LB WITHDRAW RESISTANCE(1)@(5/16")-4"LAG MOUNT SYSTEM WEIGHT= MUST BE TESTED TO WITHSTAND(USING METHOD RE-2 (J) W/2.5"EMBEDMENT LENGTH. 0.6 LBS./FT' OR RE-3)-MEASURED IN POUNDS PER SQUARE FOOT. DISTRIBUTED WEIGHT= 2.9 LBS/FP N DESIGN PRESSURE HORIZONTAL N O) DOWN/CLAMP (OUTWARD PRESSURE)- 17 PSF 0 ft Et (1)SCREW PER L-FOOT=(469)LBS HOLD DOWN DESIGN PRESSURE VERTICAL (15,312)LBS WIND UPLIFT/(469)LBS HOLD DOWN PER Q Q) C STAND=(33)STANDS FOR THIS RACKING SYSTEM (UPWARD PRESSURE)- 29 PSF (/) 0 0 7SOLAR WILL USE GREATER THAN(33)STANDS CO " FOR THIS RACKING SYSTEM. DESIGN PRESSURE VERTICAL W/SAFETY FACTOR ") � a) (UPWARD PRESSURE)x 1.25%- 36.25 PSF 0 •CALCULATIONS BASED ON MANUFACTURER'S RECOMMENDATIONS.3-SECOND GUST WIND SPEED AND PRESSURES OF 2010 BASIC WIND SPEED VELOCITIES AND PRESSURES ARE BASED ON THE FORMULAS CD W EDITION OF MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES(ASCE 7-10).AND OMG ROOFING WIND DESIGN CONTAINED IN THE ANSI I SPRI ES-1 2015'WIND DESIGN STANDARDS FOR EDGE SYSTEMS CALCULATOR. USED WITH LOW SLOPE ROOFING SYSTEMS'AND THE WIND MAPS PROVIDED IN FIGURE N- 1609 OF THE 2015 INTERNATIONAL BUILDING CODE. l— REVISIONS 1,ISSUE FOR PERMIT(04-04-22) DATE DRAWN: 04-04-22 TD/SD/SS LLB/TS 1 SHEET: PV5. 1 Customer Name(printed): . Customer Signature/Date: . ©2021 CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: PLACARD DETAIL PGE SOLAR METER PHOTOVOLTAIC INTERCONNECTION POINT FOR SERVICE PARALLEL RATED CURRENT 29.0A CALL 0da�6(`iTll• SUNLIGHT SOLAR GENERATION ON NOMINAL VOLTAGE 240VAC10 ENERGY INC ` 4S 541 322 1910 \`76 SITE INTERACTIVE SYSTEM POINT OF INTERCONNECTION SERVICE CALL PLACARD PGE-METER BASE LABEL OSCALE:NONE O SCALE:NONE O SCALE:NONE SUN NOTES: NOTES: NOTES 4 1,PLACARD SHALL CONFORM TO NEC 690.54 1.PLACARD SHALL BE ATTACHED DIRECTLY TO INVERTER 1.PLACARD SHALL CONFIRM TO ALL PGE GUIDELINES, t erpOy.,"". 2.PLACARD SHALL BE PLACED DIRECTLY AT ID COMBINER PANEL& 2.PLACARD SHALL BE WHITE LETTERING ON BLACK 2.PLACARD SHALL BE ATTACHED DIRECTLY TO METER BASE. HOUSE PANEL BACKGROUND „__._ 3.PLACARD SHALL BE WHITE LETTERING ON BLACK BACKGROUND 3.PLACARD SHALL BE WHITE LETTERING ON RED BACKGROUND W/ ___.- A MINIMUM TEXT HEIGHT OF 3/8". www.sunlightsolor.com 541-322-1910 SUNLIGHT SOLAR ENERGY,INC. 150 NE HAWTHORNE AVE. BEND,OR 97701 CCBR'158922 • PHOTOVOLTAIC SYSTEM /n\ CAUTION a, DISCONNECT POWER TO THIS SERVICE IS ALSO SUPPLIED N- FROM MULTIPLE POWER SOURCES. EACH PV SYSTEM DISCONNECT POWER SOURCE DISCONNECT SHOWN BELOW. N c cnrs- SCALE:NONE SOLAR PV SYSTEM EQUIPPED a c o NOTES, WITH RAPID SHUTDOWN 1. PLACARD SHALL CONFORM TO NEC 690.31(G)(1) 2.PLACARD SHALL BE WHITE LETTERING ON RED BACKGROUND UTILITY METER LOCATION C O 3.PLACARD SHALL BE PLACED DIRECTLY ADJACENT TO PV TV SHUTDOWN DISCONNECT I SW _ ✓ a) ` O INTERCONNECTION 40A/2P ECB IN HOUSE PANEL ISC NNE INITIATION RAPID SWITCH v LOCATION UTILITY SERVICE RAPID SHUTDOWN SWITCH PHOTOVOLTAIC SYSTEM LOCATED ON EXTERIOR j DISCONNECT LOCATION GARAGE EAST WALL C ^a` PHOTOVOLTAIC ARRAY AELScDQJ CTRIC N W TURN RAPID SHUTDOWN SWITCH TO THE OFF RAPID SHUTDOWN SWITCH IL"II,�,,�I \ POSITION TO SHUT DOWN PV fl FOR SOLAR PV SYSTEM NII. SYSTEM AND REDUCE SHOCK REVISIONS NORTH HAZARD IN THE ARRAY. 1.ISSUE FOR PERMIT(aa o-zz) o RAPID SHUTDOWN PLACARD - 0 SERVICE DISCONNECTS MAP PLACARD 0 RAPID SHUTDOWN PLACARD OSCALE:NONE O SCALE:NONE O SCALE:NONE DATE DRAWN: NOTES. NOTES. NOTES: 04-04-22 1.PLACARD SHALL CONFORM PER NEC ARTICLE 690.56 1.PLACARD SHALL CONFORM PER NEC ARTICLE 690.56 1.PLACARD SHALL CONFORM PER NEC ARTICLE 690.56 TD/SD/SS 2.PLACARD SHALL BE ATTACHED DIRECTLY TO 60A AC DISCONNECT 2.PLACARD SHALL BE ATTACHED DIRECTLY TO THE HOUSE PANEL. 2.PLACARD SHALL BE ATTACHED DIRECTLY TO THE SERVICE DISCONNECTING MEANS 3.PLACARD SHALL BE REFLECTIVE W/WHITE LETTERING ON 3.TITLE&NOTE SHALL BE BLACK LETTERS ON YELLOW BACKGROUND. 3.TITLE SHALL BE BLACK ON YELLOW BACKGROUND.REMAINING LETTERS LLB/TS /69., RED BACKGROUND. REMAINING MAP&LABELING SHALL BE BLACK ON WHITE BACKGROUND SHALL BE BLACK ON WHITE BACKGROUND SHEET: PV6.0 Customer Name(printed): . Customer Signature/Date: ©2021 • CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: MODULE SPECIFICATIONS MECHANICAL SPECIFICATION Format 740 411in.126In(including frame) 9 (1979mm,.lOAlmm x32mm) r (-o�~« - tsefete°„, .9 Weight 4851ee(22.Ok9) r--r-4 I rt powered bY' h3' Front Cover 018M(32mm)t0nmad 85 yple all ed9keewlih �� 14 Q.ANTUM/DUD/f. 1-reflection o».w.o.«. Back Cover Composite film a'aeon I 1°°,' Frame Black enodded aluminum I Cell 6.22m°nocrysleBoe GANTUM scam half cells B r-•* Junction Box 209-3.982.1262361n.0.59.0.71in w-{`] • (53-101mm x 32 60mm.22(125 N.NBI.with WPaesdi9des , Cable 4w.N So/.cable:C.).x492M(1250.1.(-)n49.2b 11250mM r - .. Connector Mudd MC4:IP68 r • - PrW - J t ' J,�.mm.ro e } • ewwA.n I-j ie nw,...) ELECTRICAL CHARACTERISTICS - ergy- POWERCLA88 Elf 390. 396 400 405 Q.PEAK DUO BLK ML-G10+ MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS.STC'(POWER TOLERANCE.5 W/-OW) Power atMPP Re. RV) 365 390 395 400 405 www.sunlightsolar.cOm 385-405 E 5500Circuit CurtenD (Al 11.04 11.07 11.10 ul4 u. 541-322-1910 g Open Circuit Voltage' Ku. [V] 45.19 45.23 4627 4630 45.34 ENDURING HIGH f Current at MPP Iro. [A] 10.59 10.65 10.71 1077 10.83 SUNLIGHT SOLAR ENERGY,INC. y Voltage atMOP V,,.. [V] 36.36 36.62 36.88 3713 37.39 150 NE HAWTHORNS AVE. PERFORMANCE 25.1 UM R ARC TR Efficiency' II t%I z195 019.E z201 z20.4 x20.6 BEND.OR 97701 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOP CC88#158922 Power at P„e,. IWI 2888 2920 2963 300.1 3038 E Snon Clrcp8CURe0 I. (AI 8.90 8.92 8.95 8.97 9.00 .AA..•. WarrantyO,CELLS E Open Circuit Voltage V.,, [V] 42.82 42.65 42.69 42.72 427E CD... x M S Current at MPP Ivn [A] 8.35 8.41 8.48 8.51 857 Voltage et MPP V. [V] 34.59 34.81 3503 35.25 3546 �r BREAKING THE 20%EFFICIENCY BARRIER ,Measursmanttolrm anp...3%AIs,-:V-.o,5%et STC:1000WMY.2542•C.AM15 according to(EC 60904-3.-a CI)5UW(m',NMOT,spectrum AM 1.5 O G.ANTUM DUO Z Technology with zero gap cell layout CD boosts module efficiency up to 20.9%. # � .-._-- --.-._ CD r;..r _.. . . ...,THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY f." ` ' srst year.Tnt max05% y Cl) -.A �II =I 0 CELLS Is the first solar module manufacturer to pass the most cOmprehen- g• deg sit per feat At least 935% Ld4 slue quality n(rpm power toff/years At 0 Et y programme the industry The new Controlled EV'of Y B6xwmamma Dower upro p nn the Independent certification institute Tl1V Rheinland. 25reers. I..L O 2. Andrea wnnm measurement rolerenc- - 0 INNOVATIVEALL-WEATHER TECH NOLOGY B' es.FVAwenemkaln accordance with E 0 C Optimal yields,whatever the weather w6h excellent - werremytemv a O CELLS - - ,,,4pp„cs, „ N !1 0 b esor9enleNan ararrespecrve - -m� � tJ yr low-IgM and temperature behavior. .,M wunM Typke module Pero ostler kw fined once tom hhw�n � > 0 ENDU RING HIGH PERFORMANCE w pw son mSTCr (25°C.10oOW n•I '>'/^� �� Long-termyleIdse0Uriy with An6LIOTeThnology,An6 PID TEMPERATURE COEFFICIENTS o CO O Technology',Hot-Spot Pnnect end Traceable Gllelity Tre.On o 1%/K) 0U.04 Tampa.mure 500Nrlenl tit V,,, 6 (%/KI 0.27 V 0 3 N y [%/K] -0.34 Npminnl Module Operating Temperer«e NMOT °F 109x5.4(d3x3•C) _//y/ EXTRE ME WEATHER RATING ------------- 4 e. High-tech aluminum alloy frame,0ErtAled for PROPERTIES FOR SYSTEM DESIGN 6 ngh snow Io400pe)endwind loads(4000Pe). Maximum sr%tam voneeev„ IV) 10008EC)/1000(uL) vv module cksaRkanen Clew ll .�I A RELIABLE INVESTMENT Maximum Series Fuse Rating (ADC) 20 Fire Rating based on ANSI/U/61730 TYPE a CD. CO • Ifwiusiv825-year product warranty end 25-year Max.Design Load.PUSS/Rol, (lbyttT 75(3800Pa1/55(2860PM Permitted Module Tarnow alum -40°F wto.185°F Ogg on Continuous Duty (-40°C UP to'05.C, REVISIONS IilteBr performance warranty'. Max.Test Load.Puan/Pull' pbNff'� 113(640DPa)/84(4000Pa) F J'sae Installation Manua 1.ISSUE FOR PERMR(04-01-22) conditionsi APT test according to ISC/T562B04.12015.meVad A(-1500V,PORI V sa.data Oast°n rear wrNrmx wwmweon. QUALIFICATIONS AND CERTIFICATES PACKAGINGINFORMATION Y � � 0 g all • F. w rob^r. d _ THE IDEAL SOLUTION FOR: o ei caroarmw � DATE DRAWN: IE R15A141EC 81730=6. /��p�s / (4� Rooftop rrayson u.s.Pau00t000e0a....0 cwl �11R C ww...+• Hari final 1940mm 1100mm 1220mm 38751k is ?s ,. reeicerah wasnge ql.Pat..emanmy51s G�0* ` pncka9 9 9 Peale peke modWes " U4-04-22 wm'ID 4"" ,.: TD/SD/SS • Maw Insl48tan lnsm/clions must be Mowed See the installs,.and operating manual or contact our technical service deportment tor funnel information on approved installation era use of LLB/TS/,,, C CELLS thep0`Engineered in Germany SHEET: H.e*5.009113 Away la.lea. 400 Spectrum Center Dille,Sute 1400.irWre,CA92818.USA I TEL.1 949 74850 96 1 EMAIL Inquvy4us q-cells.can I WES wwwq-celb.us PV7.0 Customer Name(printed): . Customer Signature/Date: ©2021 CITY STAMP. PANEL ORIENTATION: 139.5° I ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: MICROINVERTER SPECIFICATIONS-IQ 7A Data„c, iL. Enphase IQ 7A Microinverter Enphase Microinverters -?C' or fTVL'u.AL INPUTCDC) 107A-72-2-US C. _._. Commonly used module pairings' 2955 W 4V-460 W+ Module cornpatrbtilty 60-cell,66-cell and 72-cell PV model es Maximum input DC voltage 58 V Power norm tracking voltage range, IS V-58 V -- --- ---- Mm/Max start voltage 33 V,'5B V \\ Mar D shors circuit current tmcdule Isc)' 15 A L: Enphase The high-powered smart grid-ready Enphase IQ 7A Micro"'dramatically simplifies the bye rat DC pun n CC port bacOeed cs,em D A C I Q 7A Microinverter installation process while achieving the highest PV array configuration so ungrounded epou d d array,Nre additional DC brancide h required; P 9 g AC side protection requires max 20A per branch circuit system efficiency for systems with 60-cell and OUTPUT(AC) @ 240 VAC @ 208 VAC 72-cell modules. Peak output power 366 VA 295 VA erblp`/ Maximum continuous output power 349 VP 290 VA Part of the Enphase IQ System,the IQ 7A Micro Nominal(L-LI voltage/range 240 V 1211-264 V 208 V/183-229 V M m continuous output cu Trent 1.45 A(240 VACl 139 A(208 VAC) WWW.sunlightsoior COm integrates with the Enphase IQ Envoy"',Enphase IQ 541-322-1910 Nominal frequency 60 H2 Battery',and the Enphase Enlighten"monitoring Extended frequency range 41-68 Hz and sissof tware. AC short circuit fault current over 3 cycles 58Arms SUNLIGHT SOLAR ENERGY.INC.Maximum units per 20 A(L-L)branch eirculr" 11{240 VAC` 1 i(208 VAC) 150 NE HAWTHORNE AVE.BEND,OR 97701 The IQ Series Microinverters extend the reliability Ouervohage class AC port III CCBS.158922 standards set forth by previous generations and AC part backfeed current 18 mA Power factor setting 1.0 undergo over a million hours of power-on testing, Power factor(adjustable' 0 85 leading 0 e5 lags rig 4""' N enabling Enphase to provide an industry-leading EFFICIENCY @240 VAC @208 VAC a) warranty of up to 25 years. cEcweighted efficiency 970 si 96.5% O MECHANICAL Ambient temperature range -40°C to+60°C c) Relative humidity range 494 to 100'h(condensing) a) Connelotype:DC(107A72-2-US) MC4 U) D N NcD) 212 min x1 6 mom x 302 hvirnoui bracket) 0 High Power Weight 108 kg(2.38 me) C Et Peek• output power 366 VA@240 VAC and 295 VA@208 VAC C N rat con -No f n- E Approved for wet locations Yes C a) Easy to Install Poliunco degree PD3 0 U O 1 Pi •Lightweight and simple Enclosure Class II double nsulated,corrosion on resistant polymeric enclosure �-. •Faster installation with improved,lighter two-wire cabling En aura.category-JVe p re rat rig SEMI type 6outdoor co _'FEATURES •Built-in rapid shutdown compliant(NEC 2014&2017) cn- 1 Communication Power Line Communication(PLC) (73 Efficient and Reliable Momtor na E rg,ten Manager and MyEnhghten plonammg optic s (V N I,, -Optimized for high powered 60-cell and 72-cell modules T vat andble h E n 10 Envoy 0 CaOsconnecting means The AC and DC connectors s have been evaluated and approved by UL for use as the load break <Zr •Highest CEC efficiency of 97% disconnect required by NEC 690. •More than a million hours of testing Compliance CA Rule 21(UL 1741-5A) r •Class Ildouble-insulated enclosure UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B, • CAN/CSA-C22.2 NO.1071-01 •UL listed This product is UL Listed as PP Rapid Shut Down Equipment and conforms with NEC-2014 and REVISIONS NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors.when installed according manufacturer's instructions. 1.issuE FoR PERMIT(04-04-22) OS Smart Grid Ready F •Complies with advanced grid support,voltage and frequency ride- through requirements •Envoy and Internet connection required •Configurable for varying ridprofiles 1N .d Trio r.See Sc conpalitlty calculator at httas ueoohase comienun/supoorumodwe-comuatlbality. DATE DRAWN: 9 rY g9 2 CE1 k v:rrtracking voltage range is 38 V to 43V •Meets CA Rule 21(UL 1741-SA) 3 Maximum continuous maw Occurrent is 1o.2A. 04-04-22 4-Voltage g be extended beyond nominal if r g dhy the Wilt,. 5 Limrts may varyHer to local requirements to define the h f micromyerters per branchm you TD/SD/SS BL. • LLB/TS ° To learn more about Enphase offerings,visit enphase.com SHEET Toleam more about Enphase offerings,visit enphase.rwm 2023 E n E nif All gh reserved Enphase,the E ph 090.E h IQ A Enphase10 Raney,Enphase Enlghten,Enphase IC v ENPHASE. En• neo,nerv"d arks orse•.,_e. are marrade ad:.orEnpn e nergy...,< erasubject mciu"gv - u.EN PHASE PV7. 1 Customer Name(printed): . Customer Signature/Date: ©2021 CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: IQ COMBINER 3 SPECIFICATIONS Data Sheet Enphase Networking Enphase IQ Combiner 3-ES/3C-ES MODEL NUMBER rIQ Combiner 3-ES IX-IQ-AM1-240-3-ES)1 IQ Combiner 3-ES with Enphase IQ Envoy printed circuit board for integrated revenue grade PV production reetenng(ANSI C1220 Li-0.5%)and consumption monitoring(o/-2.5%).Includes a silver • solar shield to match the Encharge storage system and Enpower smart switch end to deflect heat. IQ combine-3CFS Ix 10 AMl 240-3C-ES) IQ Combiner 3C-ES with Enphase IQ Envoy printed circun board forintegrared revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring 1+,'-2 5%)Includes Enphase Mobile Connect LTE M1(CELLMODEM-MO),a plug-and-playindustrial-grade cell modem for systemssyktems up to 60 microinverters.(Available In the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, here there is adequate cellular service in the installation area:)Includes a silver solar Enphase The Enphase IQ Combiner 3-ES/3C-ES"with abot Id-ncrowatch Encharge storage system and Enpowe sw smart n h dtodeflect neat ACCESSORIES and REPLACEMENT PARTS (nluded.o md.separately) V I N Combiner n c/ (� CC Enphase IQ Envoy"'and integrated LTE-M1 cell Ensemble Communieat'oneKt Includes COMMS-KIT-01 and CELLMODEMMI,$ 15-year data plan for Ensemble siles IQ Vl/I uiner -ESI. . -LV (COMMS-CELLMODEMMI) e modem(included only with IQ Combiner 3C- Circuit Breakers Supports Eaton BR210,BR215,BR220.BR230,BR240.BR250,and BR260 circuit breakers. ,ergy. X Q AM1 240 3 ES BRK-10A-2-240 Circuit breaker,2 pole.iSA,Eaton BRzlo ES)consolidates interconnection equipment BRK-15A 2-240 Circuit breaker,2 pole,15A,Eaton BR215 X-IQ-AM1-240-3C-ES - BRK-20A-op 240 Circuit breaker,2 pole,20A,Eaton BR220 f into a single enclosure and streamlines PV arid EPLC-Si Power line carrier(communication brtdgepair),quantity-one pair www.sunllghtsolor.eoM 541-322-1910 storage installations by providing a consistent, XA-SOLARSHIELD-ES Replacement roler shield for Combiner 3-ES/3C-ES XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3-ES/3C-ES(required for EPIC-01) SUNLIGHT SOLAR ENERGY,INC, pre-wired solution for residential applications. XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3-ES!3C-ES 150 NEHAWIHORNE AVE, BEND,OR 97701 It offers up to four 2-pole input Circuits and ELECTRICAL SPECIFICATIONS CCBtX 158922 Eaton BR series busbar assembly. Rating Continuous duty System voltage 120,240 SAC.60 Hz .-+ Eaton BR series busbar rating 125 A cD -'. --- ---" --"_"-- -----"'""" -'-"- Max.continuous current rating 65 A L COMax.continuous current rerng(k m/ vput from 64 A J 0) Smart Max fuse/circuit ratog joutput1 90 A a) c) Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(0G)breakers only(not included) C •Includes IQ Envoy for communication and control y_.a Max total branch circuit breakerrating(input) 80A of distributed genera ton/90A with IS Envoy breaker included 0 •Includes LTE-M1 cell modem(included only with Production metering CT 200 A sold core r nstalled and wired to IQ Envoy O w 10 Combiner 3C-ES) - 9 P y a CD •Includes solar shield to match Ensemble esthetics and Consumption monitoring CTICT 200 SPLIT) A pair of 200 A split core current transformers C deflect heat MECHANICAL DATA O a) _ •Flexible networking supports Wi-A, --- ------ ----- ----- ----- �` • Ethernet,or cellular Dimensions(WxH%D) 37,5 x 49,5 x 16.8 cm 04,75"x 19.5"x 6.63").Height is 21 06"(5S.a c )v th mount brackets CO U O 1 i- •Optional AC receptacle available for PLC bridge Weight T5 kg(lb.S lb) C a) : •Provides production metering and consumption Ambient temperature range -40°C to 46 C(-40 to 115°F) ..' ''n^ monitoring CO Cooling Natural convection,plus heat shield vJ 5Iffli. - Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate conatrucses '. O CO --^-•- Simple Wire.ices •20 A to 50 A breaker inputs:14 to 4 AWG copper conductors a"•r •60 A breaker branch inout 4 to 1/0 AWG copper conductors Ns. -Reduced size from IQ Combiner*(X-IQ-AM1-240-2) •Main lug combined output 10 to 2.!0 AWG copper conductors Centered mountingbrackets support single -Neutral and around'.la to li0 co conductors X-IQ-AMl-240-3C-ES vp g - Always follow local code team remeots r conductor sizing stud mounting 1s g •Supports back and side conduit entry Altitude To 2000 meters(6,560 feet) REVISIONS •Up to four 2-pole branch circuits for 240 VAC INTERNET CONNECTION OPTIONS plug-in breakers(not included) Integrated Wi-Fr 802.11b/g/n 1.ISSUE FOR PERMIT Io4.o4-22) •80 A total PV or storage branch circuits Cellular CELLMODEM•Ml 4G based LTE-Mt cellular modem(included only with IQ Combiner 3C-ES) Sole - that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) COMPLIANCE DATE DRAWN: •Durable NRTL-certifed NEMA type 3R enclosure -- - - --- - -- --- -- 04-04-22 •Five-year limitedwarranty Co II ..ce. cn1>her et UL 1741,CAN/CSA C22.2N 1071,47 CFR,Part 16,Class B,ICES 003 Production metering ANSI C12 0 accuracy class 0.5(PV production) ID/SD/SS •Two years labor reimbursement program coverage - Consumption metering accuracy class 2.5 ® 1 included r ,�e le fLLB/TS X-IQ- 240-240-3-ES •uLlisted 1, °" IlL6D6D1i/CANOSA0/ No 1n1c-1 To learn more about Enphase offerings,visit maim"r SHEET To learn more about Enphase offerings,visit a pjtgge,�4m ENPHASE. '�200 E phase Energy Al rightsreserved Enphase the Eph logo,IC/Combiner 3C-ES d she- aden rser,-e c EN PHASE. �/ are-trademarks al Enpf se Energy,Inc.Data subject I°enanga..02o-oe-06 v P V 7■ 2 Customer Name(printed): . Customer Signature/Date: -- a ©2021 /v15 i O22-0o 2a2 CITY STAMP 11 PANEL ORIENTATION: 139.5° i ROOF PITCH: 30.3° I' UTILITY Co.!CO./INCENTIVE:PGE-ETO-ODOE TITLE: RACKING SPECIFICATIONS-UR COMP KIT DESCRIPTION: DRAWN BY: M DESCRIPTION: DRAWN BY: SNAPNRACK,ULTRA RAIL COMP KIT mwatkins S M` p1 v�Q]c SNAPNRACK,ULTRA RAIL COMP KIT mwatkins S �1M phfirac REVISION: Solar Mounting Solutions REVISION: Solar Mounting Solutions PART NUMBER(S): PART NUMBER(S): LJ SEE BELOW SEE BELOW "". A... UMBRELLA L FOOT PROPERTIES u � SKU DESCRIPTION 3:.;_. r 242-01219 ULTRA RAIL UMBRELLA L FOOT, LVER • `�,0- ��/ 242-01220 ULTRA RAIL UMBRELLA L FOOT,BLACK `gy"'° LL O wwwsuniightsolor.com �``I. v 541-322-7910 G1 SUNLIGHT SO AR ENERGY,INC. \ ' 0 O i50NE HAwiR7E NE AVE. �O 1.50' BEND.OR 97701 'i CCBM.158922 '.I O tn. 1.i6• w.3 0 °' Ile.- ` \� ` UV .—5•—, V) N. 4 © COMP FLASHING PROPERTIES (I) CD 0 SKU DESCRIPTION 0) ''''" \ 232-01375 COMP FLASHING,9"X 12",BLACK ALUM (/) N Ce :::23.% O 232-01376 COMP FLASHING,9"X 12",SILVER ALUM E Q U I] - -... 3-4 mu) C.) =0 ®S.W SnC91pN G3 • N /0 \ 6.J5 - POmooBAAoo®0¢dBaaao, _ O i ti 1J5 — — REVISIONS PARTS LIST , 1.ISSUE FOR PERNR(09-0422) ITEM_QTY_ PART NUMBER DESCRIPTION 105 1 1 242-92266 SNAPNRACK,UMBRELLA LAG,TYPE 3,4IN,SS 2 1 242-01219,242-01220 SNAPNRACK,ULTRA FOOT FOR U FLASHING,SILVER/BLACK 3 3 1 232-01375,232-01376 SNAPNRACK,COMP FLASHING,9IN X 12IN,SILVER/BLACK ALUM I I DATE DRAWN: MATERIALS: 6000 SERIES ALUMINUM,STAINLESS STEEL,RUBBER m35• 04-04-22 3.35' DESIGN LOAD(LBS): 405 UP,788 DOWN,236 SIDE TD/SD/SS ULTIMATE LOAD(LBS): 2006 UP,4000 DOWN,1070 SIDE 9 0 LLB/TS TORQUE SPECIFICATION: 12 LB-FT " - SHEET: CERTIFICATION: UL 2703,FILE E359313 i a.vs• i 15 WEIGHT(LBS): 0.80 ALL DIMENSIONS IN INCHES ��V/7.3 Customer Name(printed): • . Customer Signature/Date: ©2021 CITY STAMP: PANEL ORIENTATION: 139.5° ROOF PITCH: 30.3° UTILITY CO./INCENTIVE:PGE-ETO-ODOE TITLE: RACKING SPECIFICATIONS-ULTRA RAIL DESCRIPTION: DRAWN BY:SNAPNRACK,UR-40 RAIL mwatkins Sn opNrac]c REVISION: Solar Mounting Solutions PART NUMBER(S): 232-02449,232-02450,232-02451 B »«i.ms ROM:ui.1n M.e UR-40 RAIL ' PROPERTIES efgY'^� SKU FINISH / 232-02450 MILL / 232-02450 CLEAR / www.41-3sunli 2-191.com 541-322-1910 232-02451 BLACK SUNLIGHT SOLAR ENERGY,INC. 150 NE HAWTHORNE AVE. BEND,OR 97701 CCRM'158922 Nco CS) _C CI) O V/ O as EQUIVALENT PROPERTIES VJ > A 0.357 in2 'b° \ O N Ixx 0.125in4 CENT4OID O CO Iyy 0.132 in° •t Sx(TOP) 0.150 in3 Sx(BOT) 0,158 in; nr Sy(LEFT) 0.175 in3 REVISIONS Sx(RIGHT) 0.175 in3 1.155UE FOR PERMIT(04-04-22) \ \ • ALL DIMENSIONS IN INCHES DATE DRAWN: MATERIALS: 6000 SERIES ALUMINUM OPTIONS: 04-04-22 DESIGN LOAD(LBS): N/A CLEAR/BLACK ANODIZED - TD/SD/SS ULTIMATE LOAD(LBS): N/A MILL FINISH LLB/TS TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 144 SHEET: CERTIFICATION: UL 2703,FILE E359313 BOXES OF 8 WEIGHT(LBS): 5.85 ` PV7■4 Customer Name(printed): . Customer Signature/Date: ©2021