Loading...
Permit II CITY OF TIGARD MECHANICAL PERMIT COMMUNITY DEVELOPMENT Pe COMMUNITY MEC2022 00809 Date Issued: 10/12/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S135CA00902 Jurisdiction: Tigard Site address: 11357 SW GREENBURG RD C Project: Quail Court Apartments Subdivision: None Lot: None Project Description: New mini split heat pumps: (1)in unit C and(1)in unit D. Contractor: ROBBEN &SONS HEATING INC Owner: QUAIL COURT APARTMENTS LLC 2214 SE 8TH AVE 3570 SW RIVER PKWY#2307 PORTLAND, OR 97214 PORTLAND, OR 97239 PHONE: 503-233-5841 PHONE: FAX: 503-238-8849 FEES Specifics: Description Date Amount Type of Use: MF Permit Fee 10/11/2022 $176.51 Class of Work: ALT Type of Const: VB Plan Review 10/11/2022 $44.13 Occupancy Grp: R-3 Occupancy Load: 12%State Surcharge-Mechanical 10/11/2022 $21.18 Stories: Info Process/Archiving-Sm$0.50(up to 10/11/2022 $2.00 11x17) Project Valuation: $4,000.00 Fuel Air Handlers Fuel Types: Electricity Units<10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: 1 Appliances Vent Fans: Vent Systems: Total $243.82 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules Issued By: r'' Permittee Signature: / t "'TT Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONLY Received City of Tigard ` 0 ,:y: ; 4,' //� /� ':1 Permit No.: t� �z 14 13125 SW Hall Blvd.,Tigard,OR 97223 `I I CEI\/ eview Phone: 503.718.2439 Fax: 503.598.1960 �•! VVV 9. 8_2,1 Other Permit: Inspection Line: 503.639.4175 , to Re T 16`s RD P S E P 6 Date Ready/By: Suns: See Page 2 for Internet: wwwtrgazd-or.gov 0 Nottfied/Method: ///f / Supplemental Information '-z,, >s '^a•*, ['ITV a "r T"'=�u*r, t _ yr-sp rL ,> I a:... .xa zz,/i7 ° r , z> ".a.P ., r r,d,. w'? '.>,...� ''1'''''''' 1 mow.;.4 I' ' :ur ..,se.;.,on the ..lu f".th 4:.`Y^'.i..,,W„M.,. ".. Mechanical permit fees*are based on the value of the work ❑New construction Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition [I]Other: mechanical materials,equipment,labor,overhead,and profit. N � z+ �, 3 Value $ � 000 fuss' �i :..r... wa Y -. ..•na.., r�r.it��.w."�`•€r�. 1xau .a'•�"x,.,..,.,_,. �a> ' ..A .i „_....o 1,. .... ❑ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total �' Air conditioning 46.75 Job site address:t1357, SW CArecrt buret ac1 Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: 1 1 9 G.rei 04 0( �214 Furnace 100,000+BTU(ducts/vents) 54.91 1 l Heat pump 61.06 Suite/bldg./apt.no.: C...�fl Project name: Q111f. .i C oU rT Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 3 Gas fireplace/insert 33.39 1^ Flue vent for water heater or gas ��1nS V NA ec (A V M fireplace 23.32 1' Log lighter(gas) 23.32 Wood/pellet stove 33.39 _ Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ., . Other: 23.32 •-m- -`'''>' — Environmental exhaust and ventilation: Name: Qua;, Lst ( &c *4 n 45 Range hood/other kitchen ( equipment 33.39 3 `5 Address: 1 13S 1.4.1 ( f`C t 1t lour C a1J , G Clothes 1 dryer exhaust 33.39 City/State/LIP: ;i aar d d 2 to 1 2214 tilet Single-duct exhaust(bathrooms, 1 toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 i �� :s try Other: 23.32 Fuel piping: Business name: 9%oblele„ 4, t15 ‘,..i.e 4 ...z. C. $14.15 for first four;$4.03 for each additional Contact name: n Furnace,etc. Address: 15fi� Se 9;At 2.,.. AU '04 Gas heat pump Wall/suspended/unit heater City/State/ZIP:( \' ' ..c.vv o s O2._ cq-7 C i5 Water heater Phone:50;) 2..33 ,r> / Fax: :( ) Fireplace Range E-mail:(U (•na& Y'cbbcnl.L SOn`j.CQM Barbecue � ' Ix . 1,>- , Clothes dryer as5 �` � x a i - .,, Business name:O _ 3 + SA �.eoS � ., Other. FV .-- Address: 15a00 SC 91ckV6 A 'e. i iOct Subtotal City/State/ZIP:clackcaswAss O L a7O 15 Minimum permit fee $90.00) Plan review(25%of permit fee) Phone:6o )Z..7j-b•5ea, q i Fax:( ) State surcharge(12%of permit fee) CCB lic.: 1 2)4 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tn-County Building Industry Service Board Print name: ikm %A1Gr.:- Date:S,I(a',Z.L. I:\Building\Permits\MEC_PermitApp_040113.dac 440-461'7(I 1/02/COM/WEB)