Permit ,, CITY OF TIGARD MASTER PERMIT
II ' COMMUNITY DEVELOPMENT Permit#: MST2022-00166
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/29/2022
Parcel: 2S108DC06100
Jurisdiction: Tigard
Site address: 15554 SW PEACE AVE
Subdivision: RIVER TERRACE CROSSING Lot:
Project: River Terrace Crossing, Lot 67
Project Description: New detached dwelling. Model home. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES
ARE APID.
BUILDING
Floor Areas Required Setbacks Required
Stories: 2 Bedrooms: 3 First: 1308 sf Basement: 0 sf Left: 3 Parking Spaces: 0
Height: 27 Bathrooms: 3 Second: 1452 sf Garage: 383 sf Front: 12 Smoke
Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes
Total: 2760 sf Value: $380,041.04 Rear: 10
PLUMBING
Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0
Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100
Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0
Footing Drain: 100 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1
Bckflw Prevntr: 1
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1
Natural Gas Heat Pump: N Hoods: 1 Other Units: 0
Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add!500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y
Other: N Other Description: Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 2760
Owner: Contractor:
CND-RIVER TERRACE LLC WEEKLEY HOMES Required Items and Reports(Conditions)
1111 N POST OAK RD 1905 NW 169TH PLACE SUITE 102 1 Ersn Cntrl 503-639-4175
HOUSTON,TX 77055 BEAVERTON,OR 97006 2 1-HR FIRE RATED EAVES
PHONE: PHONE: 503-213-4415
FAX:
Total Fees: $23,535.95
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires ou to follow he rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
QF9_M1_nnln thrnunh( eP 0c7 r _nnQn V i may twin of th cc nr rlirart ni ioctinnc to nl Inln h,rallinn Fn'2 9'29 R7 nr 1 RIM''t 9'2aa
Issued By: i/ Permittee Signature: tr_: f-ri /t tber --1
Call 503.639.4175 by 7:00 a.m.for the next available inspection date. /
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential FOR OFFICE USE ONLY
City of Tigard ReceivedDate/By: b.f / /` e....77 Permit No.:m Cf^7o _.a)1 j,,,r�,
r 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ll / •'J' (/�� (/C/ W `�1.(/
D
Phone: 503.718.2439 Fax: 503.598.1960 L,... Date/By: 7,z, A A Other Permit 544/9
TIGARD Inspection Line: 503.639.4175 Date Ready/By: i i Juris. 1Supplemental
® See Page 2 tortInternet: www.tigard-or.gov [ified/Method: lnformation
47.
TYPE OF WORK)F 1!(aAt' REQUI' ' t DATA:I AND 2-FAMILY DWELLING
®New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application. ��
Valuation: ,000 4V 04( ‘
® 1-and 2-family dwelling ❑Commercial/industrial I
ElAccessory building ❑Multi-family Number of bedrooms: 3
❑Master builder ❑Other: Number of bathrooms: fe3 JOB SITE INFORMATION AND LOCATION Total number of floors: 2 3‘9 S
Job site address: 15554 SW Peace Ave New dwelling area: 2760 square feet l Li 52_,
City/State/ZIP:Tigard/OR/97224 Garage/carport area: 383 square feet 13 t
Suite/bldg./apt.no.: Project name:River Terrace Crossing Covered porch area: �83".-d square feet
Cross street/directions to job site: \j)NAcje( ct4 W ceXe yq f. Deck area: square feet
Other structure area: 43 square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision:River Terrace Crossing-Model Home Lot no.:67 Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
New Single Family Home to be built-2760SQFT 3 Bedroom,2.5 bath with 383 SQ Valuation: $
FT 2 car garage,a first floor st ,a 183 SQFT extended covered rear porch Existing building area: square feet
and a 43SQFT front porch e_. c OLe--'i/r,/ rreq_ New building area: square feet
® PROPERTY OWNER ❑ TENANT Number of stories:
Name:David Weekley Homes Type of construction:
Address:1905 NW 169th Place Suite 102 Occupancy groups:
City/State/ZIP:Beaverton,OR 97006 Existing:
Phone:(503)213-4415 Fax:( ) New:
❑ APPLICANT ►ZI CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name:David Weekley Homes .
Structural plan review fee(or deposit):
Contact name:Meghan Ticknor
FLS plan review fee(if applicable):
Address:1905 NW 169th Place,Suite 102
Total fees due upon application:
City/State/ZIP:Beaverton/OR/97006
Amount received:
Phone:(503)213-4409 Fax::( )
E-mail:mticknor@dwhomes.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:David Weekley Homes Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 1905 NW 169th Place,Suite 102 Solar Installation Specialty Code checklist.
City/State/ZIP:Beaverton/OR/97006 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:(503)213-4415 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lic.:213653
Total fee due upon application: $201.60
Authorized signature: This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name:Meghan Ticknor Date:6/1/22 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Mechanical Permit Application FOR OFFICE USE ONLY
City of Tigard Date/By:Rec Permit No. �, /(-
13125 SW Hall Blvd.,Tigard,OR 97223 �0 19
Plan Review
Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit:
T I G A R D Inspection Line: 503.639.4175 Date Ready/By: Juris: 0 See Page 2 for
Internet: www.tigard-or.gov Notified/Method: Supplemental Information
TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST
Mechanical permit fees*are based on the value of the work
®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all
❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit.
Value:$
CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES*
® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist.
❑Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total
JOB SITE INFORMATION AND LOCATION Heating/cooling:
Air conditioning 1 46.75 46.75
Job site address:15554 SW Peace Ave Furnace 100,000 BTU(ducts/vents) 1 46.75 46.75
City/State/ZIP:Tigard/OR/97223 Furnace 100,000+BTU(ducts/vents) 54.91
Heat pump 61.06
Suite/bldg./apt.no.: Project name:River Terrace Crossing Duct work 23.32
Cross street/directions to job site:SW Vanderwood&SW Peace Ave Hydmnic hot water system 23.32
Residential boiler(radiator or
hydronic) 23.32
Unit heaters(fuel-type,not electric),
in-wall,in-duct,suspended,etc. 46.75
Flue/vent for any of above 23.32
Subdivision:River Terrace Crossing-Model Home Lot no.:67
Other: 23.32
Other fuel appliances:
Tax map/parcel no.: Water heater 1 23.32 23.32
DESCRIPTION OF WORK Gas fireplace/insert 1 33.39 33.39
Flue vent for water heater or gas
New single family home to be built-2760SQFT 3 bedroom,2.5 bath with a 383SQFT fireplace 23.32
2 car garage,a first floor study,a 183SQFT extended covered rear porch and a Log lighter(gas) 23.32
Wood/pellet stove 33.39
43SQFT front porch. Wood fireplace/insert 23.32
Chimney/liner/flue/vent 23.32
Other: 23.32
y PROPERTY OWNER, ❑ TENANT Environmental exhaust and ventilation:
Name:David Weekley Homes Range hood/other kitchen
equipment 1 33.39 33.39
Address: 1905 NW 169t''Place,Suite 102 Clothes dryer exhaust 1 33.39 33.39
City/State/ZIP:Beaverton/OR/97006 Single-duct exhaust(bathrooms,
toilet compartments,utility moms) 3 23.32 69.96
Phone:(503)213-4415 Fax:( ) Attic/crawlspace fans 23.32
® APPLICANT ® CONTACT PERSON Other: 23.32
Business name:David Weekley Homes Fuel piping:
$14.15 for first four;$4.03 for each additional
Contact name:Meghan Ticknor Furnace,etc.
-
Address:1905 NW 169d'Place,Suite 102 Gas heat pump
Wall/suspended/unit heater
City/State/ZIP:Beaverton/OR/97006 Water heater
Phone:(503)213-4409 Fax: :( ) Fireplace
Range
E-mail:mticknor@dwhomes.com Barbecue
CONTRACTOR Clothes dryer(gas)
Business name:David Weekley Homes Other:
MECHANICAL PERMIT FEES*
Address:1905 NW 169th Place Suite 102 Subtotal
City/State/ZIP:Beaverton/OR/97006 Minimum permit fee($90.00)
Plan review(25%of permit fee)
Phone:(503)213-4415 Fax:( ) State surcharge(12%of pennit fee)
CCB lic.:213653 TOTAL PERMIT FEE
This permit application expires if a permit is not obtained within 180
days after it has been accepted as complete.
Authorized Signature: * Fee methodology set by Tri-County Building Industry Service Board
Print name:Meghan Ticknor Date:6/1/22
I:\Building\Permits\MEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB)
I
Mechanical Permit Application - City of Tigard
• Page 2 - Supplemental Information
Commercial & Multi-Family Fee Schedule:
Total Valuation: Permit Fee:
$0.00 to$500.00 Minimum fee$69.06
$500.01 to$5,000.00 $69.06 for the first$500.00 and
$3.07 for each additional$100.00 or
fraction thereof,to and including
$5,000.00.
$5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and
$2.81 for each additional$100.00 or
fraction thereof,to and including
$10,000.00.
$10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and
$2.54 for each additional$100.00 or
fraction thereof,to and including
$50,000.00.
$50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and
$2.49 for each additional$100.00 or
fraction thereof,to and including
$100,000.00.
$100,000.01 and up $2,608.71 for the first$100,000.00 and
$2.92 for each additional$100.00 or
fraction thereof.
Note: All new commercial buildings require 2 sets of plans.
I:\Building\Permits\MEC_PermitApp_040113.doc 2
Electrical Permit Application FOR OFFICE USE ONLY
T Received gy _ 9
City of Tigard Date/By: Permit#: !'1 j i 3�� �Y�
" 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review (/
Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#:
Inspection Line: 503.639.4175 Ready Date/By: Juris: El See Page 2 for
TIGARD Internet: www.tigard-or.gov Notified/Method: Supplemental Information
TYPE OF WORK PLAN REVIEW
E New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
0 Service or feeder 400 amps or more ❑Building over three stories.
❑Demolition El Other: where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings.
® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#:68260067 Job site address:15554 SW Peace Ave 100HP or more. ❑"A","E","1-2","t-3",
City/State/ZIP:Tigard/OR/97224 0 Six or more residential units. occupancy.
0 Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name:River Terrace Crossing ❑Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site:SW Vanderwood&SW Peace Ave FEE SCHEDULE
Description I Qty. I Each I Total
New residential single-or multi-family dwelling unit.
Subdivision:River Terrace Crossing Lot#:67-Model Includes attached garage.
1,000 sq.ft.or less 1 168.54 168.54 4
Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 4 33.92 107.76 1
DESCRIPTION OF WORK Limited energy,residential
New single family to be built-2760SQFT 3 bedroom,2.5 bath with 383SQFT 2 car garage (with above sq.ft.) 75.00 2
Limited energy,multi-family 75.00 2
a first floor study,a 183SQFT extended covered rear porch and a 43SQFT front porch. residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation
Name:David Weekley Homes 200 amps or less 100.70 2
Address:1905 NW 169th Place Suite 102 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Beaverton/OR/97006 601 amps to 1,000 amps 301.04 2
Phone:(503)213-4415 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: Mschiedler@dwhomes.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
El APPLICANT ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:David Weekley Homes above service or feeder fee, 7.42 2
each branch circuit
Contact name:Meghan Ticknor B.Fee for branch circuits without
Address:1905 NW 169th Place Suite 102 branch circuit
City/State/ZIP:Beaverton/OR/97006 Each add'1 branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(503)213-4409 Fax: :( ) Each manufactured or modular 67.84 2
dwhomes.com dwelling,service and/or feeder
Email:mticknor
@ Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:Garner Electric Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy El See Page 2 2
Address:2890 SE Brookwood Ave panel,alteration,or extension.
City/State/ZIP:Hillsboro,OR.97123 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(503)648-4552 Fax:( ) Investigation(1 hr min) 90.00/hr
Email:permits@garnerelectric.com Industrial plant(1 hr min) 78.18/hr
Inspections for which no fee is 90.00/hr
CCB Lie.:121159 Electrical Lie.• 4-305C Suprv.Lic.:3707S specifically listed(A hr min)
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,require Subtotal:
Print name:Charles Garner Date: 6/1/22 El Plan Review Required(25%of permit fee):
ram- ram, State surcharge(12%of permit fee):
Authorized signature: v ee:te v(. 4 TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name:Brittany Burian Date: 6/1/22 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Description I Qty. I Each I Total *
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 133.56 2
n Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
n B• urglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
M Garage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
M Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
n V• acuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
n O• ther: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(%hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Fee for each commercial system: $75.00 Subtotal(Enter on Page 1):
(SEE OAR 918-309-0000) ' Number of inspections allowed per perm it.
Check Type of Work Involved:
n A• udio and Stereo Systems
n Boiler Controls
n Clock Systems
n Data Telecommunication Installation
I I Fire Alarm Installation
n HVAC
n Instrumentation
n Intercom and Paging Systems
n Landscape Irrigation Control*
n Medical
n Nurse Calls
n Outdoor Landscape Lighting*
n P• rotective Signaling
n Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:ABuildingAPermits\ELC_PermitApp_ELR_ERE.doc Rev 06;17/2015
Plumbing Permit Application
Building Fixtures IOI: ()I11( 1 I s) (),I ,
City of T Receivedigard Dote/By. Permit No.: p;Fl 31 "f:
13125 SW Hall Blvd.,Tigard,OR 97223 Plmh ReviewIN r •
Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit No.:
i i Inspection Line: 503.639.4175 Data Ready/By: lurk 0 See Page 2 for
Internet. www.tigard-or.gov Notlled/Metlxxl: Seppknten tit l information
'uiVi .4!i {xa m ,.')1 ippl'.Orii,,60,r44ii :ii` r t SM l 'tV. .:b Iixt s `t f rite. �( i� R rtirr:
T`�+t N� .;:,tire. #. .5 . ...f .,., ,1 „,4. •,ti: �.A#w. .,.i •*r:.. v 1.1. '.i t. ., `.,.:-rr,- ,, , '--, t4i..t.a.'v'tts!i ,.:
®New construction ❑'Demolition For special information use checklist.
Description I Qty. I Ea. I Total
❑Addition/alteration/replacement 0 Other: _New 1-2-family dwellings(includes 100 ft.for each utility connection)
'q kao1 .4p .:+h +1 T. N'i 'L'M MJ { f, q 'i �- _ ..... _.
i2- r` :,..ay �+;I4'oog. ogig t� to s+'3 �% fiz.. itie SFR(1)both 312.70
®I-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 $437.78
❑Accessory building 0 Multi-family SFR(3)bath - 500.32 _
-
Each additional bath/kitchen 25.02
U Master builderyil R y �� �}0 Other: •T qq y Fire sprinkler(_sq.ft.) 1 Page 2 I
igfei ',+•,?iiO 1 'btF x d;;'iKiin.�;wI ,'AVIV ". l t r'`3 .a.A4 Site utilities:
Job site address:15554 SW Peace Avey� Catch basin or area drain 18.76
City/State/ZIP:Tigard/O107224 Drywall,leach line,or trench drain 18.76
- Footing drain(no.linear tl,: 30) 1 Page 2 87.55
Suite/bldg./apt,no.: I Project name:River Terrace Crossing Manufactured home utilities 50.03
Cross street/directions to job site:SW Vanderwaud&SW Peace Ave Manholes 18.76
Rain drain connector 18.76
Sanitary sewer(no.linearft.:_) Page 2
Storm sewer(no.linear fl.:_) Page 2
Water service(no.linear tt.:___.) Page 2
Subdivision:River Terrace Crossing-Model Home I Lot no.:67-Model Fixture or item:
Tax map/parcel no.: Backtlow preventer I • 31.27 31.27
rv1 a ri e , mn .�,ar-,•� Backwater valve 12.51
Clothes washer 1 25.02 25.02
New Single Family home to be built-2760SQ 3 bedroom,2.5 bath with 383S0FT 2 car
Dishwasher 1 25,02, . 25.02
garage,a first floor study,a 183SQFT extended covered rear porch,and a 435QFT front Drinking fountain 25.02
porch. Ejectors/sump 25.02
"" Fj " @ ' Expansion tank 12,51
Name:David Weekley Homes Fixture/sewer cap 25.02
Floor drain/floor sink/hub 25.02
Address:1905 NW 1691e'Place Suite 102 Garbage disposal 1 25.02 25.02
City/State/ZIP:Beaverton,OR 97016 Hose bib 2 25.02 50.04
Phone:(S.03)213-1415 Fax:( ) Ice maker 1 12.51 1251
7407 Us . w g raif® g ` interceptor/ghease true 25,02
Business nante: David Weekley Homes Medical gas(value:$�) Page 2
Contact name:Meghan Ticknor Primer 12.51
Roofdraln(commercial) 12.51
Address:1905 NW 169'd Place,Suite 102 ' I Sink/basin/lavatory 5 25.02 125.10
City/State/ZIP:Beaverton/OR/97006 Solar units(potable water) I. 62.54
Phone (503)2134409 I Fax ( ) _Tub/shower/shower pan 1 2 12,51 25.02
E-mail mschiedler@dwhomescom Urinal 25.02
j,`a!m •.1 rYy,. xxaew �•. Water closet 3 25.02 75.06
' ,,, rail i 4 eiF i " .a
" ' " "'t Water heater 1 37.52 37.52
Business name:Malinedal Plumbing Water piping/DWV to DWV 56,29
Address:PO Box 207 Other: 25.02
City/State/ZIP:Banks/OR/97106 • Subtotal
Phone:(503)324-0759 I Fax:( ) I
Minimum permit fee: S72.50
CCB Lie,: 102535 I Plumbing Lie.no.:34-276PB ( Plan review (25%of permit tee)
State surcharge(12%ofpennit fee)
Authorized signature: Carolina Malmedal 'B ------- TOTAL PERMIT FEE $956.91
Print name:Carolina Malinedal I Date:i6/1/22 This permit application wired if a permit is not obtained within.180 days
after it had been accepted w'complete,
°Fee methodology set by Tri•Coiwly Building Industry Service Board.
I:1BWIdineennitsMi.MU-t'ernntApc.don I0/0I/U4 44U•4GI411i0t02ICOM/WIM)
Plumbing Permit Application- City of Tigard
Page 2-Supplemental Information
Fee Schedule: Residential Fire Suppression Systems:
t i iliti Qi "r :+ 1 F 4
r� ' ..�� st .:, S i�al�e t•F�txt�ge: ,�, �" 1���? �
Footing drain-1"100' 50.03 0 to 2,000 $121.90
Footing drain-each additional 100' 37.52 2,001 to 3,600 $169,69
3,601 to 7,200 $233.20
Sewer-1st 100' 62,54 7,201 and greater $327.54 —
Sewer-each additional 100' 37,52
Water Service-1st 100' 62.54 Medical Gas Systems
Water Service-each additional 100' 37.52 r ubr� Y7 a 1a f R 9 w
Storm&Rain Drain-1st 100' 62.54 $I,00 to$5,000.00 Minimum fee$72.50
Storm&Rain Drain-each additional 100' 37.52 $5,001.00 to$10,000.00 $72.50 for the first$5,000.00 and$1,52 for
reotll*: each additional$100.00 or fraction thereof,to
k? �� 3='aF and including$10,000.00,
Inspection of existing plumbing or for $10,001.00 to$25,000.00 $148.50 for the rust$10,000.00 and$1.54 for
which no fee is specifically indicated 90.00/hr each additional$100.00 or fraction thereof,to
(minimum charge—1/2 hour) and including$25,000.00.
Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379,50 for the first$25,000.00 and$1.45 for
hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to
Reinspection Fees 90,00/hr and including$50,000.00.
Additional plan review for revisions 90,00/hr $50,001.00 and up $742,00 for the first$50,000.00 and$1.20 for
(minimum charge—1/2 hour) each additional$100.00 or Inaction thereof.
Subtotal:
Commercial Fixture Work:
Are you capping,adding or replacing fixtures? If"yes",
please indicate work performed by fixture. Failure to
accurately report fixtures could result in increased sewer fees*.
Quarti by Feature Type ^ t ' to r i �.. ;•. y4
� Plat>Ieios�Firrfuii �ts# ttIps ';
•.»oOtips for
iNei z i"eKormed. > Ca0007' Aaderl 1R lorjle Plan review is required for any of the following.
Baptistry/FontPlease check all that apply,
•
Bath -Tub/Shower - 0 Any new commercial building with water service 2"and
Jacuzzi/Whiripool greater,except systems designed and stamped by licensed
Car Wash -Each Stall engineer.
Dtive'Chru 0 New exterior plumbing site utilities for any complex structure
Cuspidor/Water Asp i ra to r as defined in OAR918-780-0040.
Dishwasher -Commercial 0 Medical gas and vacuum systems for health care facilities,
-Domestic 0 Any multipurpose fire sprinkler system.
Drinking Fountain 0 Any complex structure as defined in OAR918-780-0040.
Eye Wash
Floor Drain/sink -2" Submit, sets of plans with any of the above.
3"
-4" '4. A- 7�� MAMA' N 4
Car Wash Drain • a :,. k i} i'' P
Garbage Demestic—non-food ❑ Isometric or riser diagram is required for new buildings
Disposal -Domestic—food related that meet the qualifications above. •
-Commercial-food related •
-Industrial-food related
Ice MachiReftig,Drains
Oil Separator(Gas Station) Comments regarding fixture work:
Rec.Vehicle.Dump Station
Shower -Gang
-Stall
SinkfLav -Non-food related
-Bradley
-Commercial-food related
-Service •
Swimming Pool Filter *Note: If the fixture work under this permit results in an
Washer-Clothes Increase of sewer EDUs,a sewer permit will be issued and
Water Extractor _ P
Water Closet-Toilet fees assessed for the sewer increase must be paid before the
Urinal plumbing permit can be issued,
Other Fixtures:
C:1Users\Malmedal\AppDuta\Loea1\Microsoft\Windows\INetCache\Conte2t.Outlook\3I-I2CXR48\Plumbing Perini t,doe
I
Y City of Tigard
IIII ■ COMMUNITY DEVELOPMENT DEPARTMENT
2
T I G A R D Building Permit Review — Residential
Building Permit #: 171,4 :014a2--661 0
Site Address: «`- LI clex eVACZ 0 C
Project Name: O JW MCVAC.E (ia(Ill6 Lot #: &1-
Planning Review
Pro sal: o . r1t
Verify address/suite#active in Accela. L�1'In River Terrace: ❑ No ❑ Yes,River Terrace Review Addendum
Sitan Elements: IQErosion Control
liar opies of site plan on 8-1/2"x 11"or 11 x 17"paper LlR) fined trees with drip line and tree protection measures
Erprawn to scale(standard architect or engineer scale) Inootprint of new structure(including decks)and FFE
irth arrow rJ ty locations&easements(required for new and additions)
E S e address,project or subdivision name and lot number al iSidewalk/driveway approach
R plicant information(name and phone number) [^t]�Lo Lion of wells/septic systems
tot dimensions and building setback dimensions �l� tree size,type and location
Square footage of buildings to be demolished LQS� et names
9isting structures on site ZCorner elevations (2'contours if more than 4'diffffere . )
tot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? es El No
im "rvious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? ❑Yes Io
Cle xi Water Services—Service Provider Letter platted prior to 9/10/1995):
equired: ❑ Yes,applicant was notified No Received: ❑ Yes ❑ No
Water Meter Fixture Unit Worksheet—Additio ,Remodels and ADUs
wired: ❑ Yes,applicant was notified No Received: ❑ Yes ❑ No
( C Exemption for ADU applied for: ❑ Yes No Received: ❑ Yes ❑ No
Zi Public Facilities Improvement(PFI)Permit:
Required: ❑ Yes,applicant was notified No 722 Applie For: ❑ Yes ❑ No,stop intake
❑ Land Use Case#: 9cAZDI(c (�% Zoning: V-1-
0 Required Setbacks: Front: 12 Rear: r 0 Side: 3 Street Side: 'g Garage: 2
❑ Building Height: Max.Height: 1 5 Actual Height: 4
❑ Landscape urea: 1.4) % ❑ Lot Coverage May 80 0/0
Entrance Phi et back no more than 8'from street-facing wall Parallel to street or offset 45 degrees or less
WindowsMinimum 12%of area of all street-facing facades
Garage Garage door is behind widest street-facing wall es ❑ No,one of the following is met:
• Door extends no more than 5'from wall and there is a covered porch extending beyond garage.
• Door extends no more than 5'from wall there is a 12 sq ft.window above garage on 2nd floor.
FA Garage door width is ❑ 12'or less 50%or less of facade ❑ 60%or less and includes 7 of following:
❑ Covered porch ❑ Recessed entrance ❑ Wall offset ❑ 1'Roof eave ❑ Roof offset
❑ Fire shingles ❑ Lap Siding ❑ Roof pitch ❑ Gable,hip,or gambrel roof ❑ Dormer
❑ Accent siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ Balcony
❑ Visual Clearance ❑ Urban Forestry Plan
❑ Sensitive Lands: ❑ Yes ❑ No Type:
❑ Con.'m.ens met prior to issuance of building permit
Not> :
Approved By Planning: �,. Date: ri? / I /�
Revisions (after Building Submittal only)71/4--------- Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
I:\Building\Forms\BldgPermitRvw RES_122419.docx
r
Building Permit Submittal
Original Submittal Date: /
Site Plans: #
Building Plans: #
Building Permit#: -ter building permit above.
Workflow Routing: ning ngineering [Permit Coordinator C9�1uilding
Workflow Sign-off: E-WSTgn-off for Planning(include notes from planning review)
Route Application Documents: Zi....Eti'gineering: (1) copy of permit application, (1) site plan, (1)building plan and
or nal plan review routing form.
CWiuilding: original permit application,site plans,building plans,engineer and
beam calculations and trust details,if applicable,etc.
Notes:
By Permit Technician: z � _ Date: 6//2y
En, ineering Review
1/� Slope at building pad: 1%
❑ Conditions"Met"prior to issuance of building permit /Wei
V Easements (encroachments)per engineering conditions of approval and plat
1 Water Quality/Quantity Facility:
Assess Water Quality Fee in-lieu: ❑ Yes ,_iNo
L Assess Water Quantity Fee in-lieu: ❑ Yes " No
LIDA Facility on lot: ❑ Yes L No
❑ Final Plat Recorded:
❑ NOT Approved by Engineering: Date:
Notes:
LV Approved by Engineering: Date: ZZ
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
Permit Coordinator Review
'Conditions"Met"prior to issuance of building permit
❑ Approved,NOT Released: Date:
Notes:
Revisions (after Building Submittal only)
Revision Notice 1: Date Sent to Applicant:
Revision Notice 2: Date Sent to Applicant:
'SDC Exemption: ❑ Received Does not apply ALL-
DC Fees Entered: Wash Co Trans Dev Tax: yes ❑ N/A IS P0,04s SIX/
Tigard Trans SDC: Yes ❑ N/A � -1
Parks SDC: Yes El /I f� _`N/A �/l
•
LIDA ❑ Yes , 7 N/A
X� OK to Issue Permit
Approved by Permit Coordinator: Date: 1511 (2e)2,2—
I:\Building\Forms\BldgPermitRvw RES_122419.docx
Portland
1905 NW 169th PI,#102
David Weekley Homes Beaverton,OR 97006
Sean Vermilya
City of Tigard Planning Division
13125 SW Hall Blvd.
Tigard, OR 97223
05/26/2022
Dear Sean,
As you stated in your email on 05/26/2022,there are three (3) existing approved
Temporary Use Permits (TUP) in the River Terrace Crossing subdivision on lots that are
not currently developed.Those approvals are located on lots 19, 20, and 21. Because these
lots already have TUP approval but have not yet been developed,we can utilize one of the
existing approvals for our David Weekley model home on another lot and submit for
building permits right away.
We would like to move our David Weekley model home to Lot 67 and utilize the existing
TUP for Lot 19. We've decided to move our model home to Lot 67 to congregate all the
model homes with our Building Partners at the entrance of the subdivision.
Feel free to reach out if you have any additional questions.
Sincerely,
Max Bondar
Land Development Manager
Ph: (503) 516-5078
mbondar@dwhomes.com
Atlanta•Austin • Charleston•Charlotte• Colorado Springs • Dallas/Ft. Worth
Denver• Houston• Indianapolis •Jacksonville • Minneapolis/St. Paul •Nashville• Orlando
Phoenix •Portland• Raleigh • Salt Lake City• San Antonio • Sarasota•Tampa
Copyright 0 2019 David Weekley Homes-All Rights Reserved(ALL0109049)
City of Tigard
u Deferral Until Occupancy Request
TIGARD Washington County Transportation Development Tax (TDT),Transportation and Parks System
Development Charges (SDCs)
This form is to be signed and submitted prior building permit issuance or,if no building permit is required,then
upon land use approval(TMC 3.24, as amended by Ordinance No.21-09).
Date: 6/22/2022 Site Address: 15554 SW PEACE AVE
Project River Terrace Crossing Land Use Case or
Name: (DW Homes) Building Permit#: MST2022-00166
T#ax Lot Lot 67 Aotal m mount*:
$10,903.00
TDT N/A Total TSDC $10,348.00
Amount: Amount*:
*The total TSDC amount shown above is the sum of$6,690.00 for TSDC-Improvement,$ 386.00 for TSDC-
Reimbursement,and$3,272.00 for TSDC-River Terrace,if applicable..
*The total Parks SDC amount shown above is the sum of'I!•,278.00 for Parks-Improvement, $ 1.739.00 for Parks-
Reimbursement,and either$ N/A for Parks-Neighborhood or$2,886.00 for Parks-Neighborhood River Terrace.
This constitutes my request to defer payment of the TDT, TSDC, and Parks SDCs, as provided above, to
prior to final inspection.
Payment of the TDT,TSDC,and Parks SDCs may be deferred until issuance of the occupancy permit. In
requesting this option, I understand that any deferred TDT,TSDC,and Parks SDCs must be paid prior to final
inspection.
TDT may only be deferred if the TDT is greater than the amount for a single-family residence. I further
understand that the amount of TDT due on deferred obligations shall be the amount in effect at the time of
issuance of the building permit.
For a deferral request to be accept both the Property Owner and the Developer must sign this request.
_ 6/3/21
Property Owner: Date: ‘/)2/ /
V
Developer: Date:
Permit Coordinator: AVAIA ov Date: 6/22/2022
FOR OFFICE USE ONLY—SITE ADDRESS:
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
Iii - II Transmittal Letter
TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov
TO: Allyson Armstrong DA 1CD
DEPT: BUILDING DIVISION JUN i' 2 2022
FROM: Meghan Ticknor CITY OF TIGARD
BUILDING DIVISION
COMPANY: David Weekley Homes
PHONE: 503-213-4409 By.✓~'�
EMAIL: Mticknor@dwhomes.com
RE: 15554 SW Peace Ave MST2022-00166
(Site Address) (Permit Number)
River Terrace Crossing-Lot 67
(Project name or subdivision name and lot number)
ATTACHED ARE THE FOLLOWING ITEMS:
Copies: Description: Copies: Description:
Additional set(s) of plans. 3 Revisions: Plan sheets
Cross section(s)and details. Wall bracing and/or lateral analysis.
Floor/roof framing. Basement and retaining walls.
Beam calculations. Engineer's calculations.
Other(explain):
REMARKS: Revised Plan Sheets, Engineering Response Letter, David Weekley Response Letter.
FrO OF ICE USE ONLY
Routed to Permit Technicii : Cg(3 a 'Z Z Initials: 6-t"
Fees Due: Ili Yes V Vl 6- Fee Description: Amount Due:
).- ...) O p E-- $
$ G/
Special
Instructions:
Reprint Permit(per PE): ❑ Yes ❑ Done
Applicant Notified: Date: � 51\<U— Initials: i
Branden Taggart
From: Branden Taggart
Sent: Wednesday, June 1, 2022 3:48 PM
To: mticknor@dwhomes.com
Subject: River Terrace Crossing, Lot 67 Sales Office
Hi Meghan,
After receiving the River Terrace Crossing model home submittal for lot 67, I realized that there is going to be a sales
office in the garage. I wanted to make sure that you are aware that the sales office will require separate commercial
permits: Building, Mechanical, Electrical, and a Plumbing permit if applicable.
In order to convert the garage to a sales office, we will need to receive the following:
• Building permit: (3) sets of floor plans.
• Mechanical permit: (2) sets of mechanical plans and (2) sets of cut sheets.
• Electrical permit:This permit can be created online: https://aca-prod.accela.com/TIGARD/Welcome.aspx.
• Plumbing permit: Only applicable if separate plumbing fixtures will exist for the sales office.
Thanks,
Branden Taggart
1,4 City of Tigard
I Senior Permit Technician
Community Development
ttamo
13125 SW Hall Blvd
Tigard, OR 97223
(503)718-2449
brandent@tigard-or.gov
1