Report
INCARLSON ROOFING , , COMPANY INC. KER222- 00036 Sorrento Animal Hospital Scope of Work 1. Remove and dispose of existing lower BUR roof system wall flashings and leave Metal wall panels in place. 2. Furnish and install over existing roof system, a layer of%" HD Cover Board mechanically fasten with plates and fasteners. 3. Furnish and install new roof system with 60mi1 TPO reinforce membrane. 4. Furnish and install all pre-manufactured pipes boots, t-patches, and wrap all penetrations. 5. Furnish and install pre-manufactured inside/outside TPO corner flashings at curb penetrations. 6. Furnish and install new TPO base flashing surround all curb penetrations and walls. 7. Furnish and install new TPO Clad Metal drip edge at gutter. CITY OF TIGARD Approved [ Nf' Contitionally Approved [ I For only the work as described in: PERMIT NO. RE , <. , c„, , See Letter to: Follow [ I AttachN I 1 Job Address: \ �1' � �; 10-i L � By: `' Date:n___ 550 SW Maple Street • PO Box 1695 • Hillsboro OR 97123 • T:(503)8461575 • F:(503)640 2122 • www.carlsonroof.com • CCB#159686 ... ! . AP North Dakota St ,- '''-- ''''-` :',J-•- - --7,''','"'-%'''''''-''.-",-,;.-',2,'"--,r,„7,,, . 411 ,..0. I P -,.-''',71" ,7: ' 4.. • at 1 t, 1 • ' 4 , , 4440--- 111 jii , ,,,•,,-‘. -,1,*••.„„.• ••• • 1 ' ''"' CF ; II .. I , . al , _ 1[10 tar' :, * H - I •i , "4,--,-- , ‘ _ , r." -,!.* --,, ' 1.• on it I • -., -.,- ''' '' ' '4114i 1 ,7 .: ' , li PO lie,e ..... -. it,,,1 • ..mr,,, v • • ., *z. .• ,.. i .0.1111.,.......,. 1:i e't I" * :4 ,itlin 1 i k * , o ' 'f* 1 • % -400/14101010/41etaaaimassaillief , 4 1,. k 'i. ........ _, 4 I ° OP - _ • 1 kr- 4110.4:1 . r 4 •/ • l• 1 ' , ',.... - .• -. ,Irt , ,-k.' 0 . t • • 1 I t # it 1-• i. . 'A .... , •". ,, EXPERIENCE THE CARLISLE DIFFERENCE CoIRLISLE SYNTEC SYSTEMS SecurShieId' HD POLYISO Insulation Productivity Boosting Features and Benefits: Lightweight and easy to cut,handle,and swlr install-no crumbling of material oa » 5 times higher R-value than gypsum cover a _ :.- boards /the weight of /4 g gypsum cover boards uoost- y. µ, Product Characteristics Panel sizes: - 4'x 8'(1220 mm x 2440 mm) - 4'x 4'(1220 mm x 1220 mm) Overview » Panel thickness:1/2"(13 mm) Carlisle's SecurShield HD Polyiso Insulation is a rigid roof insulation » Weight:0.343 lbs/sq.ft. panel composed of a high-density,closed-cell polyisocyanurate foam core laminated to a premium-performance,coated glass facer(CGF). - 11 lbs(4.99 kg)per 4'x 8' panel Suitable for both re-roofing and new construction applications, - 5.5 lbs(2.49 kg)per 4'x 4'panel SecurShield HD is specifically designed for use as a cover board over a variety of substrates.SecurShield HD delivers an R-value of 2.5,which Installation is significantly higher than roof cover boards made with other materials Mechanically Attached Single-Ply Systems such as wood fiber or gypsum. Each SecurShield HD panel must be secured to the substrate with approved Features and Benefits Carlisle fasteners and plates.Butt edges and stagger joints of adjacent panels.Install the roof membrane according to Carlisle specifications. » High-density insulating cover board Fully Adhered Single-Ply Systems » Achieves a UL Class A direct to combustible deck rating-Maximum roof slope 1":12" Carlisle's SecurShield HD may be secured to the roof deck using Carlisle's FAST'"and Flexible FAST adhesive,OlyBond500®insulation adhesive, » Exceptional protection against hail,rooftop traffic, mold,and moisture fasteners and plates,or hot asphalt(appropriate to the deck type). » High-density formulation achieves FM severe hail rating(SH) For adhesive coverage or fastening patterns and requirements,please • 2 times higher R-value than wood fiber boards contact Carlisle's Design Services group. Butt the edges of the insulation panels and stagger the joints.Install the membrane according to Carlisle » Compatible with all Carlisle single-ply roofing systems(Except Ballast) specifications. » Coated glass facer provides strong bond for adhered roofing applications Review Carlisle specifications and details for complete installation information. 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax:717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE G4RL/SLE SYNTEC SYSTEMS SecurShield HD POLYISO Insulation Codes and Compliances Typical Properties and Characteristics • ASTM C1289,Type II,Class 4,Grade 1 (109 psi max.) Physical Property Test Method Value (IBC) Compressive• International BuildingCode IBC Section 2603 Strength ASTM D1621 109 psi max » UL Standard 790,263 and 1256:Component of Class A Roof Systems Dimensional Stability ASTM D2126 <0.5%linear change (refer to UL Roof Materials'system directory) (7 days) » FM Standards 4450/4470:Class 1 approval for steel roof-deck Water Absorption ASTM C209 <1%volume constructions(refer to FM RoofNav) R-value ASTM C518 2.5 » California Codes of Regulations,Title 24,Insulation Quality Standard Thickness License#TI-1418 Service Temperature 260°F(126°C)or less • Third party certification with PIMA Quality Mark for Long Term Resistance to Mold ASTM D3273 Passed Thermal Resistance(LTTR)values Typical properties and characteristics are based on samples tested and are not guaranteed • CAN/ULC S704,Type 3,Class 2 for all samples of this product.This data and information is intended as a guide and does not yPreflect the specification range for any particular property of this product. » Florida Building Code Approval LEED'° Information Precautions Pre-consumer Recycled Content 0% Insulation must be protected from open flame and kept dry at all times.Install only as much insulation as can be covered the same day by completed roof- Past consumer Recycled Content 9% covering material.Carlisle will not be responsible for specific building and Manufacturing Locations Smithfield,PA roof design,for deficiencies in construction or workmanship,for dangerous FranklinPark,IL loose,UT conditions on the jobsite,or for improper storage and handling.Technical Montgomery,NY specifications shown in this literature are intended to be used as general Lake City,FL guidelines only and are subject to change without notice.Call Carlisle for Terrell,TX, more specific details or refer to PIMA Technical Bulletin No.109:Storage and Puyallup,WA Handling Recommendations for Polyiso Roof Insulation. Solar Reflectance Index(SRI) N/A 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com 06.06.19®2019 Carlisle. Carlisle,SecurShield,Flexible FAST and FAST are trademarks of Carlisle. REPRINT CODE:605075-"SecurShield HD Polyiso Product Data Sheet" OlyBond500 is a registered trademark of OMG.LEED is a registered trademark of the U.S.Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE GeIRL/SLE 8 YIN!7r r' S N'S a, P A Sure-Weld` . • Reinforced Membrane » Excellent chemical resistance to acids,bases and restaurant exhaust emissions » UL 2218 Class 4 hail rating » Exceptional resistance to heat,solar UV,ozone and oxidation Manufactured using a hot-melt extrusion process for complete scrim encapsulation » Enhanced with the OctaGuard XT Q OCTRGURRD XT weathering package WEATHERING PACKAGE » Standard Colors: ' t � k 85 Overview :„ White Gray Tan Carlisle's Sure-Weld TPO reinforced membrane is a premium,heat- weldable,single-ply thermoplastic polyolefin(TPO)sheet designed for » Special Colors: new roof construction and re-roofing applications.Sure-Weld High Slope (HS)membrane is formulated with additional flame retardant for higher slope fire code approvals.Sure-Weld Extra is 80 mils(2.03 mm)thick for significantly higher strength and weatherability. Sure-Weld TPO membranes use advanced polymerization technology Slate Gray Med Bronze Terra Gotta Patina Green Rock Brown that combines the flexibility of ethylene-propylene(EP)rubber with the "Sure-Weld HS Special Color TPO membranes are available in limited heat weldability of polypropylene.All Sure-Weld TPO membranes include sizes. Refer to Carlisle's Sure-Weld HS TPO Special Color Program Sell OctaGuard XT-,an industry-leading,state-of-the-art weathering package. Sheet for details. OctaGuard XT technology enables Sure-Weld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe climates. 1 Physical properties of the membrane are enhanced by a strong polyester 16. Sustainable Attributes fabric that is encapsulated between the TPO-based top and bottom plies. Carlisle SynTec Systems'focus has always been innovation-Innovation The combination of the fabric and TPO plies provides high breaking and to solve problems,improve performance,reduce labor,and above all, tearing strength,as well as excellent puncture resistance.The relatively improve sustainability.Carlisle is committed to driving sustainable and smooth surface of the membrane produces a total surface fusion weld efficient processes in the design and manufacturing of our products. that results in a consistent,watertight,monolithic roof assembly.The • Up to 10%pre-consumer recycled content membrane is environmentally friendly and safe to install. » Fully recyclable when used in mechanically attached systems Features and Benefits » 3rd-party verified Environmental Product Declaration available » Sure-Weld TPO available in 4-,and 6-ft(121.92 cm and 182.88 cm) » NSF P151 certification for rainwater catchment* perimeter sheets and 8-, 10-,and 12-ft(243.84 cm,304.80 cm,and 365.76 cm)Sure-Weld field sheets* » California Title 24 compliant** • Outstanding puncture resistance » Free of Living Building Challenge red list chemicals » Excellent fire resistant assemblies *White only,produced in Tooele,UT **White and Tan only » Environmentally friendly and stable formulation » Excellent resistance to impact and low temperatures 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax:717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Sure-Weld TPO Reinforced Membrane Precautions Optional APEEL"" Protective Film » Sunglasses that filter out ultraviolet light are strongly recommended,as tan and white surfaces are highly reflective.Roofing technicians should Shield Carlisle's Sure-Weld TPO membrane rr:- dress appropriately and wear sunscreen. from dirt and scuffs during installation with APEEL Protective Film.Factory applied and » Surfaces may become slippery due to frost and ice buildup.Exercise easy to remove,APEEL eliminates the need PROTECTIVE FILM caution during cold conditions to prevent falls. for rooftop cleaning upon project completion. » Care must be exercised when working close to a roof edge when » Ideal for re-roofing,re-cover,and new construction projects the surrounding area is snow-covered,as the roof edge may not be clearly visible. » Simple and easy to remove » Saves time and money when compared to pressure washing » Use proper stacking procedures to ensure sufficient stability of the rolls. » Protecting from dirt maintains maximum membrane reflectivity » Exercise caution when walking on wet membrane.Membranes may be and long-term performance slippery when wet. Installation » Store membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with light-colored,breathable,waterproof Simply order membrane with APEEL,install,and remove the film to tarpaulins.Membrane that has been exposed to the weather must be reveal a clean,new roof. prepared with Weathered Membrane Cleaner prior to hot-air welding. » APEEL Protective Film should be removed from within areas » Take care not to stand or place heavy objects on the edge of folded- that are to be heat-welded together.In areas that do not require over membrane,as this could cause a hard crease in the membrane. heat-welding,the APEEL Protective Film can be left in place for up to 90 days without degrading due to its excellent heat-and » Maximum sustained temperature not to exceed 160°F(71°C)for TPO UV-resistance. membrane. » When the installation of the entire TPO roofing system is » Do not use razor blades or other sharp tools to cut the APEEL Protective complete,remove and discard the APEEL Protective Film. Film while it is still adhered to the TPO membrane as damage to the underlying membrane may occur.Pull the protective film away from the membrane prior to cutting. Installation » Remove APEEL Protective Film by pulling towards the center of the roof.Do not remove the film by pulling towards the roof edge. Sure-Weld TPO roofing systems are quick to install,as minimal labor and few components are required.TPO systems are installed using an » A static electric charge may develop when removing APEEL Protective Automatic Heat Welder,making sheet welding fast,clean,consistent,and Film from the surface of the membrane sheet.To avoid the possibility easy to learn,while reducing strain on the roofing technician. of ignition,lids must be closed on any flammable products and a fire extinguisher should be readily available. Fully-Adhered—membrane is adhered to a suitable substrate utilizing an appropriate bonding adhesive » Color membranes will`fade'over time mainly due to the ultraviolet portion of sunlight.Since most roof surfaces are exposed to variable Mechanically Fastened—membrane is attached to the roof deck over sunlight,some areas will be more susceptible to color changes caused by a suitable substrate utilizing plates and fasteners which are overlapped UV fading.Warranties for color membranes do not cover fading of colors. with membrane Induction-Welded—membrane is attached over a suitable substrate via an induction welding tool being placed over the membrane where a fastened TPO induction welding plate is located to weld the two components together Review Carlisle specifications and details for complete installation information. CARL/SLE SYNTEC SYSTEMS Sure-Weld • I Reinforced me Extreme Testing for Severe Climates Environmental Cycling subjects the membrane to repeated cycles of heat ASTM Standard D6878 is the material specification for Thermoplastic aging,hot-water immersion,and xenon-arc exposure. Polyolefin-Based Sheet Roofing.It covers material property requirements » ASTM requirement—none for TPO roof sheeting and includes initial and aged properties after heat » Carlisle Extreme test*: and xenon-arc exposure.As stated in the scope of the standard,"the tests and property limits used to characterize the sheet are values intended to - 10 days heat aging at 240°F(116°C)followed by ensure minimum quality for the intended purpose."Carlisle's goal is to - 5 days water immersion at 158°F(70°C)followed by produce TPO that delivers maximum performance for the intended purpose - 5,040 kJ/m2(2000 hours at 0.70 W/m2 irradiance)xenon-arc of roofing membranes.Maximum performance requires the membrane to exposure far exceed the requirements of ASTM D6878. *Test specimen is 2.75"(69.85 mm by140 mm)by5.5"p piece of Heat Aging accelerates the oxidation rate that roughly doubles for each membrane with edges sealed. 18°F(10°C)increase in roof membrane temperature.Oxidation(reaction *Criterion—after 3 complete cycles,test specimens shall remain with oxygen)is one of the primary chemical degradation mechanisms of flexible and not have any cracking under 10x magnification while roofing materials. wrapped around a 3"(76.2 mm)-diameter mandrel. Carlisle Testing- Heat Aging Supplemental Approvals,pp Statements ASTM Requirement Sure-Weld Requirement and Characteristics: ASTM TEST 32 weeks** >128 weeks 1. Sure-Weld TPO meets or exceeds the requirements of ASTM D6878 240°F Standard Specification for Thermoplastic Polyolefin-Based Sheet **Heat exposure comparable to 3,120 weeks(60 years)at 185°F for 8 hours/day. Roofing. » Test specimen is a 2"by 6"(50.8 mm by 152.4 mm)piece of 45-mil 2. Sure-Weld TPO membranes conform to requirements of the US (1.14 mm)membrane unbacked,placed in circulating hot-air oven. E.P.A.Toxic Leachate Test(40 CFR part 136)performed by an independent analytical laboratory. » Criterion—no visible cracks after bending aged test specimen around 3"(76.2 mm)-diameter mandrel. 3. Sure-Weld TPO was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head. Q-Trac testing combines accelerated weathering with real-world conditions 45-mil(1.14 mm)was watertight after an impact energy of 12.5 J using an array of ten mirrors to reflect and concentrate full spectrum (9.2 ft-Ibf)and 60-mil(1.52 mm)was watertight after 22.5 J(16.6 sunlight onto membrane test specimens.The Q-Trac device automatically ft-lbf).80-mil(2.03 mm)Extra was watertight after an impact tracks the sun's path from morning to night.Also,it adjusts to compensate energy of 30.0 J(22.1 ft-Ibf). for seasonal changes in the sun's altitude.Eight years in Q-Trac testing is equal to 40 years of real-world exposure.Carlisle requires its Sure-Weld 4. All FM approved assemblies have been tested to pass FM 4470 for TPO membranes to pass the equivalent of 40 years of exposure in the Q-Trac. foot traffic resistance. Carlisle Testing— Q-Trac ASTM 06878 Requirement Sure-Weld Requirement ASTM TEST N/A Equivalent of 40 years WA of exposure 800-479-6832 I P.O.Box 7000 I Carlisle, PA 17013 I Fax:717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE G4RLISLE SYNTEC SYSTEAAS Sure-Weld TP  Reinforced Membrane Typical Properties and Characteristics LEED Information Pre-consumer Recycled Con t °' 10% Physical Pro erty ASTM D6878 45-mil 60-mil 80-mil Extra rb p Requirement (1.14 mm) ` (1.52 mm) (2.03 mm) Post consumer Recycled Content" MS 0% Tolerance on Nominal Thickness,% +15,-10 ±10 ±10 ±10 Manufacturing Location Senatobia, ASTM D751 test method Tooele Carlisle, P PA Thickness Over Scrim,in.(mm) 0.015 min 0.018 typical 0.024 typical 0.034 typical - --- Solar Reflectance Index(SRI) ASTM D7635 optical method,average (0.380) (0.457) (0.610) (0.864) 1 99(white)86(tan) of 3 areas Breaking Strength,lbf(kN) 220(976 N) 225(1.0)min 250(1.1)min 350(1.6)min ASTM D751 grab min 320(1.4)typical 360(1.6)typical 425(1.9)typical Radiative Properties for Cool Elongation Break of Reinforcement,% 15 min 15 min 15 min 15 min Roof Rating Council (CRRC) ASTM D751 grab method 25 typical 25 typical 25 typical and LEED Tearing Strength,Ibf(N) 55(245)min 55(245)min 55(245)min 55(245)min ASTM D751 proc.B 8 in.x 8 in. 130(578) 130(578) 130(578) Test White Tan Gray typical typical typical Method TPO TPO TPO Brittleness Point,°F(°C) -40(-40)max -40(-40)max -40(-40)max -40(-40)max - ASTM D2137 -50(-46)typical -50(-46)typical -50(-46)typical CRRC ASTM 0.79 0.71 0.46 Initial solar C1549 Linear Dimensional Change,% ±1 max ±1 max ±1 max ±1 max reflectance ASTM D1204,6 hours at 158°F 0.2 typical -0.2 typical -0.2 typical CRRC-Solar ASTM 0.70 0.64 0.43 Ozone Resistance,no cracks 7X ASTM PASS PASS PASS PASS reflectance after C1549 D1149,100 pphm,168 hrs 3 years (uncleaned) UV Exposure(Xenon Arc),no cracks PASS PASS PASS PASS CRRC-Initial ASTM 0.90 0.86 0.89 7X ASTM 6155,min. thermal emittance C1371 exposure 10,080 kJ/m2 CRRC-Thermal I ASTM 0.86 0.87 0.88 (4,000 hrs-0.70 Wm') -_.._. _._ emittance after C1371 Water Absorption Resistance,mass% ±3.0 max ±3.0 max ±3.0 max . ±3.0 max 3 years (uncleaned) ASTM D471 top surface only 166 hours 0.90 typical 0.90 typical 0.90 typical at 158°F water LEED-Thermal ASTM 0.90 0.86 0.85 ._ emittance E408 Factory Seam Strength,lbf(N)ASTM 66(290)min 66(290)min 66(290)min 66(290)min SRI-Initial ASTM 99 86 53 D751 grab method ----- (Solar Reflectance E1980 Field Seam Strength,lbf/in(kN/m) No requirement 25(4.4)min 25(4.4)min 40(7.0)min Index) ASTM D1876 tested in peel 50(8.8)typical 60(10.5)typical 70(12.3)typical SRI-3 year aged 85 77 48 Water Vapor Permeance,Perms No requirement 0.10 max 0.10 max 0.10 max (Solar Reflectance ASTM E96 proc.B 0.05 typical 0.05 typical 0.05 typical Index) Puncture Resistance,lbf(kN) No requirement 250(1.1)min 300(1.3)min 400(1.8)min FTM 101C,method 2031(see 325(1.4)typical 350(1.6)typical 450(2.0)typical supplemental section) Radiative Properties (Initial) Properties After Heat Aging for Special Colors ASTM D573,32 weeks @ 240°F or 8 PASS PASS PASS PASS p weeks @ 275°F No cracking No cracking No cracking No cracking Reflectance Emittance SRI No cracking when bent around 3" ±1.5 max 1.0 max 1.0 max 1.0 max n...._s ."� .-._. Bronze Medium Be ' 0.28 0.86 29 diameter mandrel -- Weight Change,% Rock Brown 0.25 0.87 26 Typical Weights lb/ft2(kg/mT) 0.23(1.1) 0.29P(1.4) yw W0.40(2.0) Slate Gray 0.38 0.87 42 Terra Cotta 0.25 0.86 25 Typicalproperties and characteristics are based on samples tested and are not guaranteed for all samples of this product. Patina Green 0.25 0.88 25 This data and information is intended as a guide and does not reflect the specification range for any particular property of - --- this product. Solar Reflectance Index(SRI)is calculated per ASTM E1980. ��Q,SSIFt ICC The SRI is a measure of the roof's ability to reject solar � heat,as shown by a small temperature rise.It is defined so ��ii /II C that a standard black(reflectance 0.05,emittance 0.90)is ® ��7� APPROVED C R C 0 and a standard white(reflectance 0.80,emittance 0.90) Rom,,.,.,, ® is 100.Materials with the highest SRI values are the coolest 0,,DE6, irk, choices for roofing.Due to the way SRI is defined,particularly Ua7A hot materials can even take slightly negative values and MIAMI•DADE COUNTY %ill 0 kPFRDVED particularly cool materials can even exceed 100. q.i)EA\Cp II�I . + 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com 12.27.21©2021 Carlisle. Carlisle,Sure-Weld,OctaGuard XT.and APEEL are trademarks of Carlisle. REPRINT CODE:600515 TPO-2012-"Sure-Weld TPO Reinforced Membrane Product Data Sheet" LEED is a registered trademark of the U.S.Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE iG4RLISLE SYNTEC SYSTEfVIS ISure-Weld Certified I Pipe Seals Fabricated Accessory Installation 1. Cut pipe seal between the two raised"ribs"to the desired diameter as illustrated on the flange of the pipe seal.(Do not cut off both raised "ribs".) .,, 2. Pull TPO Pipe Seal over pipe until base flange is in contact with the membrane.(Application of heat to the top portion of the TPO Pipe Seal may be necessary to allow installation over the pipe.) 3. Mark pipe around the top of the TPO Pipe Seal. 4. Pull TPO Pipe Seal upwards on pipe until mark on the pipe is visible. 5. Install Water Cut-off Mastic below mark which indicates the top of the installed TPO Pipe Seal. 6. Pull TPO Pipe Seal back down over pipe and into position. 7. Heat weld the TPO Pipe Seal base flange to deck membrane(the Overview hand-welder temperature setting should be between 5 and 6). Let Carlisle simplify your next Sure-Weld TPO installation with TPO Molded 8. Install a stainless steel universal clamping ring to provide constant Pipe Seals.TPO Pipe Seals are injection-molded,pre-formed fleshings compression of the sealant. for pipes 3/a"(19.0 mm)to 8"(203.2 mm)in diameter.TPO Pipe Seals Review Carlisle specifications and details for complete installation are packaged in boxes of eight and come with universal stainless steel information. clamping rings. Carlisle's TPO Molded Pipe Seals are part of the Certified Fabricated Precautions Accessory(CFA)program.Certified Fabricated Accessories are the » Remove all lead and other flashing. only factory-fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. » Temperature of pipe must not exceed 160°F(71°C). » When used with mechanically fastened membrane,install a minimum Features and Benefits of four fastening plates around pipe penetrations.Position fastening • Provides a reliable method of waterproofing round pipe penetrations plates around the penetration so the plates are covered by the pipe seal flange.A minimum 11/2"-wide weld must be maintained around the » Provides a substantial labor savings compared to field fabricating from outer edge of the flange beyond the plates.If fastening plates cannot non-reinforced flashing be installed in a manner to allow a minimum 11/2"weld,the plates » Provides more consistent appearance than field-fabricated pipe fleshings must be placed outside the TPO Pipe Seal flange and covered with a » Double-ribbed cutting guide provides easier,smoother and straighter cuts reinforced TPO overlay. » Rib design also keeps the clamp in the proper position for the life of the Store pre molded pipe seals in a cool,shaded area and cover with light roofing system colored,breathable,waterproof tarpaulins.TPO Pipe Seals or membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner prior to hot-air welding. Productivity Boosting Features and Benefits: » Up to 60%labor savings compared to traditional �ziviry field fabrication ab� r » Quick and simple installation with no stretching required , » Provides a consistent,finished appearance r 4� Roc—'C 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax:717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE C4RLISLE SYNTEC SYSTEMS Sure-Weld TPO 1 Pipe Seals Typical Properties and Characteristics LEED' Information Sizes 3"to 8"0.D.pipe(19.0 to 203.2 mm) Pre-consumer Recycled Content + 0% Packaging 8/box Post-consumer Recycled Content 0"/" Weight(each) 0.63 lbs(0.3 kg) Manufacturing Location Bloomingdale,IL Material Injection-molded TPO Solar Reflectance Index(SRI) N/A Color White,gray and tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Please use the chart below to cross-reference your pipe size with the proper step to cut as shown. Copper Tubing (C.T.S.) Nominal tube size '" 1" 11/4" 11/2" 2" 21/2" 3" 4" 5" 6" 8" Pipe 0.D. .88 1.13 1.38 1.63 2.13 2.63 3.13 4.13 5.13 6.13 N/A Step of boot used 1 1 1 1 Y2 2 2 3 4 5 6 N/A Schedule 40/80 Steel Pipe - PVC Standard - Polyethylene Pipe IPS Nominal tube size 3L., 1" 114" 11/2" 2" 21/2" 3" 4" 5" 6" 8" Pipe 0.D. 1.05 1.32 1.66 1.90 2.38 2.88 3.50 4.50 5.56 6.63 8.63 Step of boot used 1 1 11/2 11/2 2 3 3 4 5 6 8 Cast Iron Pipe Pit Class A&Spun 100-250 Pit Class B,C&D Nominal tube size 2" 3" 4" 6" 8" 2" 3" 4" 6" 8" Pipe O.D. 2.50 3.96 4.80 6.90 9.50 N/A 3.96 5.00 7.10 9.30 Step of boot used 2 4 5 6 N/A N/A 4 5 6 N/A Sewer- Soil Pipe PVC Plastic SDR 35&41-Cast Iron Soil Pipe no hub-service weight&extra heavy .,. Nominal tube size 4" 4" 4" 4" 6" 6" 6" 6" 8" 8" 8" 8" Pipe O.D. ( 4.22 4.38 4.30 4.62 6.28 6.30 6.30 6.62 8.40 8.38 8.38 8.75 Step of boot used 4 4 4 4 6 6 6 6 8 8 8 8 Conduit EMT Nominal tube size 1O" 1" 11/4" 134" 2" 234" 3" 3Y4" 4" Pipe 0.D. �� .922 1.16 1.51 1.74 2.19 2.88 3.50 4.00 4.50 Step of boot used 1 1 1 1Y2 2 3 3 4 4 Conduit IMC Nominal tube size 3/4" 1" VA" 11/2" 2" 211" 3" 3Y2" 4" Pipe O.D. 1.02 1.29 1.63 1.88 2.36 2.85 3.47 3.97 4.46 Step of boot used 1 1 11/2 11/2 2 3 3 4 4 Conduit Rigid Nominal tube size %., 1" VA" 11/2" 2" 21fi" 3" 3114 "4" 5 Pipe O.D. 1.05 1.32 1.66 1.90 2.37 2.87 3.5 4 4.5 5.56 Step of boot used 1 1 1Y2 1Y2 2 3 3 4 4 5 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax: 717-245-7053 I www.carlisiesyntec.com 12.120.17®2014 Cadisie. Carlisle and Sure-Weld are trademarks of Carlisle. REPRINT CODE:604453-"Sure-Weld TPO Pipe Seals Product Data Sheet" LEED is a registered trademark of the U.S.Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE G4RLISLE SYNTEC SYSTEMS Sure-Weld' - .1 Certified Fabricate Universal Corners Accessory Installation h£ � � See the diagram on page two for cutting instructions.The cutting instructions are also molded into each part. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. Typically,a setting of 6 on a scale of 10 is appropriate for welding Universal Corners. ayr , Outside Corner 1. Clean the surface to be welded with Weathered Membrane Cleaner. � : 2. Place the outside Corner into position over the outside intersection rr �� of the corner. 3. Begin welding at the bottom point of the outside corner.Weld � ..� straight up the vertical portion of the corner.Weld each side of the outside corner,working from the inside toward the outside. Overview 4. Weld the bottom flange starting on the inside and working towards the outer edges. Use the edges of the roller to crease the corner into Carlisle's labor-saving,pre-molded Sure-Weld TPO Universal Corners are any membrane step-off to create a proper seal. ideal for flashing corners on a variety of details. 5. Once the material has completely cooled,probe all welded edges of Carlisle's Sure-Weld TPO Universal Corners are a part of the Certified the corner to ensure watertight performance. Fabricated Accessory(CFA)program.CFAs are the only factory-fabricated TPO accessories that meet the stringent quality tolerances required to be Inside Corner included in a Carlisle warranted roofing system. 1. Clean the surfaces to be welded with Weathered Membrane Cleaner. 2. Position the inside corner into the corner setting. Begin welding at Features and Benefits the innermost corner point and work up and away from the corner. • Conforms easily to details on new construction installations,where Weld each side of the inside corner,working from the inside toward right angles are common the outside. » Each Universal Corner can be cut into one outside corner or one 3. Weld the bottom flange starting on the inside and working towards inside corner the outer edges.Use the edge of the roller to crease the corner into • Large,6"-wide deck flange reduces the need for T-Joint Covers any membrane step off to create a proper seal. (when used as an outside corner) 4. Once the material has completely cooled,probe all welded edges of » Provide a substantial labor savings compared to field-fabricating from the corner to ensure watertight performance. non-reinforced flashing Review Carlisle specifications and details for complete installation » More professional,consistent appearance than field-fabricated corners information. Productivity Boosting Features and Benefits: • Up to 60%labor savings compared to traditional J0swiry field fabrication 6o r » Quick and simple installation with no stretching required » One product to utilize for both an inside or �ti� outside corner gOos T. ter..;� .. �� __ __ s 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax:717-245-7053 I www.carlisiesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE G4RLISLE SYNTEC SYSTEMS Sure-Weld • Universal Corners Typical Properties and Characteristics Each Universal Corner can be cut `— Thickness 0.060"(1.5 mm) into one Inside or Outside Corner. Packaging 20 per carton Color White,gray and tan Material j Injection-molded TPO Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. I LEED'r Information Pre-consumer Recycled Content 0% Post-consumer Recycled Content 0% Manufacturing Location i Bloomingdale,IL Inside Corner Outside Corner Precautions » Store TPO Universal Corners in a cool,shaded area and cover with light-colored,breathable,waterproof tarpaulins.TPO Universal Corners or TPO membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner before hot-air welding. 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax:717-245-7053 I www.carlislesyntec.com 11.22.17 m 2017 Carlisle. Carlisle and Sure-Weld are trademarks of Carlisle. REPRINT CODE:600427-"Sure-Weld TPO Universal Corners Product Data Sheet" LEED is a registered trademark of the U.S.Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE 4RL/SLE SYNTEC SYSTEMS Insulation Fastening Plates Typical Properties and Characteristics Size 3"Round Weight/Carton 37 lbs.(16.8 kg) , 1,000/Carton Quantity Material Galvalume° Coated Steel a ; Thickness 26 Gauge Corrosion Resistance Galvalume-Coated Steel meets FM-4470 �wr a s l guaranteed � < � for allTypica samplesproperties of thisand product.Thischaracteristics dataare and informationbasedonsamples is intendedtestedand as aare guidenot and does not reflect the specification range for any particular property of this product. Overview Carlisle's Insulation Fastening Plates are specifically designed for attachment of insulation and cover boards under Carlisle roofing systems. Insulation Fastening Plates are stamped from Galvalume®-coated steel for long-term protection against corrosion.The round design provides an even distribution of loads and eliminates sharp corners that can damage insulation. Installation 1. Position Insulation Fastening Plates per Carlisle Specifications. 2. Secure Insulation Fastening Plates using the appropriate Carlisle fastener. Review Carlisle specifications and details for complete installation information. Precautions » Eye protection is recommended during drilling and installation of fasteners. 800-479-6832 I P.O.Box 7000 I Carlisle,PA 17013 I Fax:717-245-7053 I wwwe.carlislesyntec.com 04.13.16©2018 Carlisle. Carlisle is a trademark of Carlisle.Galvalume is a trademark of RIEC International,Inc. REPRINT CODE:604795-"Insulation Fastening Plates Product Data Sheet" . CARLSON ROOFING COMPANY INC. Sorrento A • Hospital Re _ Roof F) • t Application 550 SW Maple Street • PO Box 1695 • Hillsboro OR 97123 • T:(503)8461575 • F:(503)640 2122 • www.carlsonroof.com • CCB#159686