Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (2)
n=s2.1922.-aptcic to ?.. X� a cc SIC' AUb 2z �` CITY OF TIGARD ®Simplex TrueAlert Multi-Candela Notification ApptitiNgNE DIVISION . UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSync Operation Compatible Features Visible only(V/O)24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: ��s • Intensity is selectable as 15,30,75,or 110 candela with , visible selection jumper secured behind strobe housing e � • Operation is compatible with ADA requirements(refer to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity,supervised notification appliance circuit(NAC) • Regulated circuit design ensures consistent flash output Wall Mount Strobes and provides controlled inrush current • Rugged,high impact,flame retardant thermoplastic FIRE FIRE housings are available in red or white with clear lens • Listed to UL 1971 and ULC S526 7 Strobes provide synchronized flash for use with: • Simplex°fire alarm control panels with NACs selected Ceiling Mount Strobes to provide strobe synchronization or SmartSync two-wire control Descri•tion • 4009 IDNet NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes.The enclosure designs are both impact and vandal • Separate SmartSync Control Modules(SCMs)that resistant and provide a convenient strobe intensity • provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output,on-site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi-flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens)that mounts to a single or double gang,or • Wall mount strobes easily mount to single gang,double 4"square standard electrical box.The cover can be gang,or 4-inch square outlet box quickly removed(a tool is required)and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes.Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection,and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation,a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity.An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975-9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes* Proper selection of visible notification is dependent on occupancy,location,local codes,and proper applications of:the National Fire Alarm Code(NFPA 72),ANSI • Refer to page 2 for guard listing.This product has been approved by the California State Al 17.1;the appropriate model building code:BOCA, Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning ICBO,or SBCCI;and the application guidelines of the • material presented in this document.Refer to page 2 for listing status of wire guards. Americans with Disabilities Act(ADA). t" Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4906-0001-5 11/2014 Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their SmartSync two-wire control is available from: reflections can be seen from one location,synchronized • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, flashes reduce the probability of photo-sensitive reactions and 4100U Fire Alarm Control Panels(refer to as well as the annoyance and possible distraction of individual product data sheets for more information) random flashing.These multi-candela strobes are . 4009 IDNet NAC Extenders(refer to data sheet synchronized over a two-wire circuit when connected to 54009 0002) compatible NACs,to compatible Synchronized Flash Modules,or to SmartSync Control Modules. • SmartSync Control Module(SCM)Model 4905-9938 (refer to data sheet S4905-0003) SmartSync Two-Wire Control Additional SmartSync compatible notification Some applications desire the audible notification appliances include separate horns and combination appliances to be capable of being silenced before the horn/strobe notification appliances. alarm condition is reset(on-until-silenced)while the visible notification appliances are kept activated until the alarm condition is reset(on-until-reset). SmartSync operation mode provides this function using a single circuit(two-wire operation). Product Selection Multi-Candela Visible Notification Appliances(Strobes) Model Mounting Housing Color "FIRE"Lettering Description 4906-9101 Wall Red White 4906-9103 White Red Multi-candela strobe with intensity selectable as: 15,30,75,or 110 candela;synchronized flash rate; 4906-9102 CeilingRed White SmartSync two-wire control compatible '�"— 49tlFi g104 White Red Wall Mount Strobe Adapters Model Description Dimensions • 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm) 5-3/8"H x 5 1/4"W x 1-5/8"D deep surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2 3/4"D (200mmx130mmx70mm) Ceiling Mount Strobe Adapter Model Description Dtmens o 4905-9910 Surface Mount Adapter Plate;zinc plated; required for mounting to 4-7/8"x 3-1/8"x 0.060"D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules(refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with 1-3/8"x 2-7/16"x 13/16" in/out 18 AWG(0.82 mm )wire leads,rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output;mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D For Wall mount strobes 4905-9993 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4905 9961* Wall mount 6-1/16"H x 6-1/16"W x 3-1/8"D Red wire guard with mounting plate,compatible with (154 mm x 154 mm x 79 mm) 4905 9926* Ceiling mount semi-flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8"deep • (156mmx111 mmx73mm) *UL listed by Space Age Electronics Inc. • 2 S4906-0001-5 11/2014 Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC;see Note 1 below Flash Rate 1 Hz . Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122° F(0°to 50°C) Humidity Range 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC' 40 mA 63 mA 124 mA 168 mA Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC' 67 mA 111 rnA 207 mA 281 mA at other voltages 24 VDC' 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting /gym �m �m `r 0 0 9 is comp atible Patible with r r o single gang,double gang,and 1 1 I 4"(102 mm)square boxes, /, — 7, X:-/ ; 1-1/2"(38 mm)deep,by others l o� L �Zl IMPORTANT!WALL MOUNT INSTALLATION HEIGHT REFERENCE a 1�)- Bottom of lens O z Q _ O J is either even with,or slightly Electrical Wiring access hole /1 ,N - above bottom box outline jy © © a e /l I / of compatible / J boxes Wiring terminals — °, EE 1 C that the entire lens minimum Double gang(3) be not less than 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only • from rear of housing; I+s I o factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-5 11/2014 Ceiling Mount Strobe Installation Reference Handy box, 1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang • V5744S)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others Also can be attached to boxes ,r./ mounted to drop ceiling T-bar with clips(ERICO No.512 or equal) 0 0 0 4905-9910 Adapter Plate,required for /surface mount with handy box unless i/ using the 4905-9926 wire guard I. r 1 -I _ .•.:.a. - Ceiling mount strobe Optional 4905-9926 wire guard 1''tI I �, with mounting plate lei; �i ��il IN Strobe intensity viewing slot n g.,;.F Intensity selection plug, accessible only from rear of lens housing;factory setting is 15 cd - Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt o and Optional Wire Guard --n Surface mount conduit and `f O IIII box shown for reference -----"Ni. 4"(102 mm)square e ,-- r ������-� box profile, 1-1/2 "` I ii=1�1=1�lii1 i II ' (38 mm)deep !- 1��.1.���' O ° I Optional 4905-9961 1 NM r I Wire Guard 2 n Strobe M‘ '`-`- Wili__ ' (, 4905-9931 Adapter Platel ' _t Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). E®S i m p 1 Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0001-5 11/2014 www.simplex-fire.com O'2014 Tyco Fire Protection Products.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. 5®SimplEx TrueA/ert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable Features Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon " strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements(refer , to important installation information on page 3) • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens F, E Operates over a two-wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on theFIRE, same two-wire circuit • "On-until-silenced"and"on-until-reset"operation on the same two-wire pair • SmartSync horn activation of Temporal pattern,March R , . Time pattern(at 60 BPM),or on continuously • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate • Class B operation requires connection to a compatible 1 a �a SmartSync NAC or to SmartSync Control Module (SCM)4905-9938 Wall and Ceiling Mount ANs • Class A operation when connected to the 4905-9938 Descri•tion SCM or with 4100U series fire alarm control panel NACs Multi-Candela TrueAlert A/Vs with horn and Wall mount AIVs features: synchronized strobe provide convenient installation to standard electrical boxes.The enclosure designs are • Wiring terminals are accessible from the front of the both impact and vandal resistant and provide a convenient housing providing easy access for installation, strobe intensity selection. Since each model can be inspection,and testing selected for strobe intensity output,on-site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA(stairwells,small rooms,highly reverberant areas,etc.) Wall mount AN housings are a one-piece assembly (including lens)that mounts to a single or double gang,or Optional adapters and wire guards: 4"square standard electrical box.The cover can be • Wall mount AN adapters are available to cover surface quickly removed(a tool is required)and covers are mounted electrical boxes and to adapt to Simplex® available separately for color conversion. 2975 9145 boxes Ceiling mount A/Vs install using standard 4"electrical • UL listed red wire guards are available for wall or boxes. Color choice is determined by model number. ceiling mount A/Vs Visible notification appliance(strobe): Strobe Intensity Selection • 24 VDC xenon strobe; intensity is selectable as 15,30, During installation,a selection plug at the back of the 75,or 110 candela with visible selection jumper secured housing determines the desired strobe intensity.An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current * This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing Audible notification appliance(horn): 7125-0026:317 for allowable values and/or conditions concerning material presented in this Low current,24 VDC electronic horn with harmonicallydocument.Accepted for use—City of New York Department of Buildings—MEA35-93E. • Refer to page 2 for listing status of wire guards.Additional listings may be applicable; rich sound output suitable for either steady or coded contact your local Simplex product supplier for the latest status.Listings and approvals operation(Temporal or 60 BPM March Time pattern) under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. • UL listed to Standard 464 S4906-0002-6 11/2014 Strobe Application Selection SmartSync Two-Wire Control Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy,location,local codes,and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A 117.1;the appropriate model building code:BOCA, while the strobe remains flashing.The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-until-reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, reflections can be seen from one location,synchronized and 4100U Fire Alarm Control Panels(refer to flashes reduce the probability of photo-sensitive reactions individual product data sheets for more information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet random flashing.The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938(refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi-Candela ANs Model Mounting Housing Color "FIRE"Lettering Description 4906-9127 Wall • Red White 4906-9129 White Red Horn with Multi-Candela Strobe;strobe intensity selectable as: 15,30,75,or 110 candela;operates with SmartSync two-wire 4906-9128 Red White control Ceiling �► 490Fr 9130 White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm)deep 5-3/8"H x 5-1/4"W x 1-5/8"D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe=4-3/8"(111 mm) 4905 9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Optional Sound Damper;package of 20;field installed adhesive backed 4905-9838 horn output attenuator;reduces output 5 to 6 dBA 1-3/4"Diameter(44.5 mm) NOTE:After Sound Damper installation,measure sound level to ensure with 0.31"(8 mm)sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905 9938 SmartSync Control Module with Class B or Class A output;mounts in 4" 4"x 4-1/8"x 1-1/4"D (102 mm)square box;refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"H x 6-1/16"W x 3-1/8"D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate,required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension,use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0002-6 11/2014 A/V Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC;see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C); 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC' 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting /MTh cT �� Mounting is compatible with f single gang,double gang,and e 0 0 • 4"(102 mm)square boxes, c ( 1 ° ( 1 r) IMPORTANT!WALL MQVNT 1-1/2"(38 mm)deep,by others INSTALLATION HEIGHT REFERENCE o A ce Optional 4905-9838 Sound Damper,field attached I Bottom of lens to attenuate sound 5 to 6 dBA I 1 ) is either even a i Electrical with,or slightly o ;u -: t - box outline - tj. ',^ 0 above bottom Wiring access hole /0-C� ` �\ _ of compatible rJp , / /"- — / boxes Wiring terminals for 0 p / lQo ) / I SmartSync operation 1 -, Ilgi Mounting Holes: NFPA 72 requires 80"(2.03 m) 4"square that the entire lens minimum ® �..m,.,a Single gang(2) Double gang(3) be not less than 80"and not greater • than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only f-- from rear of housing; . pij R E factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-6 11/2014 Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box Four mounting clamps included,two each side 0 0 1 lillI MET '?..', • C eiling reference, i,-_� Lc ® flush mounted box ►� — Optional 4905-9915/-9916 Adapter, �s � recommended for surface mounted box Wiring terminals are Optional 4905-9927 Red Wire Guard located behind the housing '- 1; 0-- F - M E End View I -7. Strobe intensity viewing slot R ! 2' -Intensity selection plug, accessible only from rear of lens housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt ,Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard MEj Surface mount conduit and O IIII box shown for reference ----�-- 4"(102 mm)square ;j� P7�1�1�I�I�1�11 �+- box profile,1-1/2" �!Ih -- -- i����i � nill 11 (38 mm)deep MAIM mmin ����1,i O O I Optional 4905-9961 1 1 _- -_ 11=1D ' Wire Guard p=._.. :__..7.5 R _I.d_I - uilll Il��__I-_1' 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). f3®S i m p I EX Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0002-6 11/2014 www.simplex-fire.com O 2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. 5 SimplEx TrueAlert Multi-Candela Notification Appliances UL,ULC,CSFM Listed;FM Multi-Candela, High Intensity(non-addressable)Strobe and Horn/Strobe - Approved* Features Ceiling Mount 24 VDC high intensity notification appliance common features: Strobe appliances install using standard single gang electrical boxes. Horn/strobe appliances install using standard 4"electrical boxes.Color • Xenon strobe with intensity selectable as 135,177,or 185 candela; choice is determined by model number. visible selection jumper is secured behind strobe housing • Regulated circuit design ensures consistent flash output and provides , F controlled inrush current of FIRE • Control is compatible with Simplex SmartSync two-wire operation • Operation is compatible with ADA requirements --I ; I • Rugged,high impact,flame retardant thermoplastic housings available in red or white with clear lens • Models are available for wall or ceiling mount • Strobe operation is UL listed to Standard 1971 Appliances with audible notification(horn): • Low current electronic horn with harmonically rich sound output . FIRE suitable for either steadyor coded operation(Temporal or 60 BPM . , , P (T p � � ......- •. , March Time pattern) i • Horn operation is UL listed to Standard 464 Strobes provide synchronized flash for use with: Figure 1: High Intensity Strobes and Horn/Strobes • Simplex fire alarm control panels and NAC Extenders when selected to provide strobe synchronization or SmartSync two-wire control Strobe Intensity Selection • Separate strobe Synchronization Modules or SmartSync Control During installation,a selection plug at the back of the housing Modules(SCMs)that convert conventional NAC inputs to a Smartsync determines the desired strobe intensity.An attached flag with black output letters on a highly visible yellow background allows the selected intensity SmartSync two-wire operation provides: to be seen at the side of the strobe lens. • Horns controlled separately from strobes on the same two-wire circuit, activated as Temporal pattern,March Time pattern(at 60 BPM),or on Strobe Application Selection continuously Proper selection of visible notification is dependent on occupancy, location,local codes,and proper applications of:the National Fire Alarm Wall mount appliance features: Code(NFPA 72),ANSI A117.1;the appropriate model building code: • Wiring terminals are accessible from the front of the housing providing BOCA,ICBO,or SBCCI;and the application guidelines of the Americans easy access for installation,inspection,and testing with Disabilities Act(ADA). • Covers are available separately to convert housing color •AN models have an available UL listed sound damper for locations SmartSync Two-Wire Control requiring attenuation of 5 to 6 dBA(stairwells,small rooms,highly SmartSync operation mode allows a two-wire circuit to provide the ability reverberant areas,etc.) to activate both the horn and strobe on the same NAC and then allow Optional adapters and wire guards: the horn to be silenced while the strobe remains flashing.The horn operates as"on-until-silenced"while the strobe operation is"on-until- •Wall mount AN adapters are available to cover surface mounted reset." electrical boxes and to adapt to 2975-9145 boxes • UL listed red wire guards are available for wall or ceiling mount ANs. SmartSync Control Sources Description SmartSync two-wire control is available from: 4006,4007ES Hybrid,4008,4010,4010ES,4100ES,and 4100U Fire Convenient Selection and Installation Alarm Control Panels(refer to individual product data sheets for more TrueAlert multi-candela high intensity appliances provide convenient information) installation to standard electrical boxes.They are both impact and 4009 IDNet NAC Extenders(refer to data sheet S4009-0002) vandal resistant and provide a convenient strobe intensity selection. SmartSync Control Module(SCM)Model 4905-9938(refer to data sheet Since each model can be selected for strobe intensity output,on 54905-0003) site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall Mount Housings are a one-piece assembly(including lens)that mounts to a single or double gang,or 4"square standard electrical box.The cover can be quickly removed(a tool is required)and covers are available separately for color conversion. *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7125-0026:333 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable;contact your local product supplier for the latest status. • • S4906-0011 Rev.4 10/2018 SSimplEx Multi-Candela, High Intensity(non-addressable)Strobe and Horn/Strobe - Product Selection Table 1:Strobe(V/O)Product Selection Model Housing Lettering ;Mounting:;Description 4906-9109 Red White Wall 4906-9111 :White Red 'Multi-candela strobe with intensity selectable as:135,177,or 185 candela; 4906-9110 Red :White Ceiling synchronized flash rate;SmartSync two-wire control compatible 4906-9112 'White Red Table 2:Horn/Strobe(A/V)Product Selection Model j• usin ..,. ..1Lette g., ;Mounting Description ,11.0,11 4906-9139 Red White Wall 4906..9141 White :Red Horn and multi-candela strobe with intensity selectable as:135,177,or 185 4906-9140 Red :White candela;synchronized flash rate;operates with SmartSync two-wire control .White 'Red Ceiling Table 3:Wall Mount Common Accessories 14041* n Dirt'ienSionS 4905-9937 Red 5-3/8"H x 5-1/4"W x 1-5/8"D(136 mm .Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm)deep surface x 133 mm x 41 mm)depth w/strobe= 4905-9940 White `mounted boxes 4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to 2975-9145 box(typically for retrofit,may be mounted '8-5/16"x 5-3/4"x 0.060"Thick(211 mm vertical or horizontal) )(146 mm x 1.5 mm) AN only;Optional Sound Damper;package of 20;field installed adhesive backed horn output attenuator;reduces output 5 to 6 dBA 4905-9838 Note: 1-3/4"Diameter(44.5 mm)with 0.31"(8 mm)sound opening After Sound Damper installation,measure sound level to ensure compliance with applica- ble code requirements V/O Model AN Model Description :Dimensions 4905-9992 4905-9994 Red Wall Mount Replacement cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D(130 mm x 4905-9993 4905-9995 White Wall Mount Replacement cover with red"FIRE'lettering 1127 mm x 38 mm) Table 4:Wire Guards and Adapters Dimensionsr��> , 4905-9961* AN or V/0 Wall Mount Red Wire Guard with Mounting Plate,for semi-flush or surface 6-1/16"H x 6-1/16"W x 3-1/8"D(154 mounted boxes mm x 154 mm x 79 mm) 4905-9926 V/0 Ceiling Mount Red Wire Guard with Mounting Plate,for semi-flush or surface mounted'6-1/8"x 4-3/8"x 2-7/8"deep(156 mm x boxes 111 mm x 73 mm) 4905-9927* AN Ceiling Mount Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3"(216 mm x 156 mm x 176 mm) 4905-9928* Red Adapter Plate,required to mount 4905-9927 guard to surface mounted electrical box 9"x 7"(229 mm x 178 mm) 4905 9910 Surface Mount Adapter Plate;zinc plated;required for mounting to handy box;not needed 4-7/8"x 3-1/8"x 0.060"D(124 mm x 79 when using 4905-9926 guard mm x 1.5) 4905-9915 White :Ceiling Mount AN Surface Mount Adapter Box Extension,use to cover 1-1/2" 4-3/4"x 6-7/8"x 1-1/2"deep,(121 mm x 4905-9916 Red :deep surface mounted boxes 175 mm x 38 mm) Note:*UL listed by Space Age Electronics Inc. Page 2 • S4906-0011 Rev.4 10/2018 • SSimplEx Multi-Candela, High Intensity(non-addressable)Strobe and Horn/Strobe - Installation Reference,Surface or Semi-Flush Mounting Mounting is compatible with single gang,double gang,and 4' ...�i �, (102 trim)square boxes,1-112"(38 mm)deep,by others y / AN housing is shown for , , r o �/, _ c 0 reference:optional44 t Sound Damper(shown)attenuatesIMPORTANT!WALL MOUNT sound 5 to 6<ISA,field installed o, rINSTALLATION HEIGHT REFERENCE r i Bottom of lens p e;4 "x; -i r is either even Wiring access hole tit-; with,ar st hfiy Eiectdcal `f I aGi7lie E�toin boxtries, outline 12.411A44 0l.,_`1'I, Of Compaht e Winng terminals 7M tI(5xe5 4 „ „,.., i Mounting Holes. t ^44 rsquare(4) Nl F A 72 requites $t?"(2.03 m) a ,' D Sang( ' ,.„i ii Double gang(3.) that the entire lens minimum ® be not less than i' 80'and not greater than 96"above the Transparent housingfinished floor r and tens assembly Intensity selection plug, • accessible only from rear of j -`_ housing;factory setting is 177 nu i+ I ( j ,} Figure 3: Wall mount Ij Strobe intensity installation height reference Removable cover,NV Shown for Reference viewing slot (toot is required to remove cover) Figure 2: Installation reference,surface or semi-flush mounting Note:Figure 2 shows optional 4905-9838 sound damper. Page 3 S4906-001 1 Rev.4 10/2018 Ei Sim plEx Multi-Candela, High Intensity(non-addressable)Strobe and Horn/Strobe • Ceiling Mount High Candela Appliances Installation Reference Ceilingreference; . taa mm)square tax surface mounted box t-t/2"(38 rnm)mbumum depth 11 Singly gang Pax"remold V57�1a5) #candy box. -9 t2"(38 aunt deep a say*t mrrr>cyan,supplied by others box 2�t 50 or equal)o ti 519 or equal)supper by others o can be attached to boxes _.. mounted;to drop ceiling T.bar with% '"" clips(ERICA No.512 or equal) CeilingOptiona reference, 1 ""� ., recommended for surfaae'�box )lush mounted box I Adapter Per, .. ' required for surface mount rs Optional Adapter Plate, p a! with handy box unless using required tor surface mounted electrical box sadee j f r r Four mounting damps included,two each .� ! � �•..� ,.., .,." ...., r< - . e,r Ter.,„-r4..- .� _.....-ram- .... 1 1 a. 1 ( 1t10 Rlafaence li .,:,,.,,t) .,A.„,tj..1 ......",..3.,......ist,,t" Optional Red Wire Guard Optional wire Wiring terminate are located Ceiling mountstrobe guard with mounting plate behind the housing Coiling:mount AN ,„ ` Strobe intensity viewing slot () — , Ad!, Ahr End Viw.V I Intercity saffron plug,accessible t only horn rear of lens housing; i factory setting is 177 cd AN Reference .--,., f Figure 4: Ceiling Mount High Candela Appliances Installation Reference Note:Figure 4 shows: • Optional 4905-9915/4905-9916 Adapter for A/V installation,recommended for surface mounted box • Optional AN 4905-9927 Red Wire Guard • 4905-9910 Adapter Plate,required for surface mount V/O installation with handy box unless using the 4905-9926 wire guard • Optional 4905-9926 wire guard with mounting plate for V/O installation • Page 4 S4906-0011 Rev.4 10/2018 5SimplEx Mufti-Candela, High Intensity(non-addressable)Strobe and Horn/Strobe - Wall Mount Installation Reference;Adapter Plate,Guard,and Adapter Skirt Surface Mounting Reference wig f3pttortal Adapter Skirt and Optional Wire Guard t I eIIIIIIIIIIIIIIINIIIMIIIIIPV Surface mount conduit and 0 IIIIIIIIIIIIIIIIIIIII9 box shown for reference -s .I R e1 4 (102 nm)square ( _-emsf .I I f *-.....• Orem box p►of le,1-li? ° ,r b Il W ` ? ( 8 mmi deep Ii rl' y jj c3ptuard M 4" a -�...�.� Q I Wire Guard ` t 1 1-1111111111116-1111_ Adapter Rate Optional Surface Mount Adapter Skirt 0 �`� Optional io nal VYre Guard Ad r Puke (shown here for reference only, can be used on other mounting options) Figure 5: Wall Mount Installation Reference;Adapter Plate,Guard,and Adapter Skirt Note: Figure 5 shows: _ 1. 4905-9931 Adapter Plate 2. 4905-9961 Optional Wire Guard 3. 2975-9145 back box 4. Optional Surface Mount Adapter Skirt.1-1/2"deep:4905-9937,Red;4905-9940,White(conduit knockouts are provided on all four sides) V/O shown for reference,AN mounts the same. Page 5 • 54906-0011 Rev.4 10/2018 £iSimplEx Multi-Candela, High Intensity(non-addressable)Strobe and Horn/Strobe - Specifications Refer to Instructions 579-859 for additional information. Table 5:Specifications Spe[ifiCation Rating Rated Voltage Range UL Listed Rating :Regulated 24 DC;see Note 1 below ULC Listed Rating i20 VDC to 30 VDC per ULC 5526-M878 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 132 to 122°F(0°to 50°C);10%to 93%,non-condensing at 100°F(38°C) Screw Terminal Connections 118 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring AN and V/O Wall Mount ;5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Dimensions(with lens) V/O Ceiling Mount 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) AN Ceiling Mount 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Horn Output Characteristics 12400 to 3700 Hz sweep,modulated at 120 Hz rate :Steady Sound Output Coded Sound Output(see Note 2 below) UL 464 Reverberant Wall Mount ,Ceiling Mount Wall Mount Ceiling Mount AN Horn Ratings,dBA @ 10 ft Chamber 186 dBA 187 dBA 82 d8A 83 dBA (3 m);at 24 VDC(see Note 2) Anechoic Chamber 192 dB. A 93 dBA......................................................92 dBA.._..__...._...._........._.............._...93 dBA............................_........_................ Angular Dispersion :Per ULC S525;-3 dB at 45°off-axis for both wall and ceiling mount models ;Visible Only ;AudibleNisible(AN) 1 , 77 .1 - --.._..__ _....__.; ._....... 1. .. ,__......... ---._..................... ............. .__......_.._........... (Maximum RMS Current Rating per 35 cd cd 85 cd 135 cd 177 cd 185 cd. Wall Mount :Strobe Setting(see Note 3 below) 1330 mA 1410 mA 430 mA 350 mA 440 mA 455 mA Reference RMS Currents at118 VDC 1279 mA 1347 mA 1364 mA '296 mA i372 mA 385 mA 'other voltages 124 VDC .................. ......... 209 mA 1260 mA 1273 mA 222 mA I279 mA 289 mA ;Visible Only(V/O) AudibleNisible(AN) Maximum RMS Current Rating per 1135 cd 1177 cd 1185 cd ;135 cd 1177 cd 185 cd Ceiling Mount ;Strobe Setting(see Note 3 below) 356 mA 431 mA 447 mA 389 mA 1456 mA 463 mA :Reference RMS Currents at 18 VDC :316 mA 7383 mA 397 mA i346 mA 1405 mA 412 mA other voltages 24 VDC......237A_...........__...;...._.-._._........................................;... .......... 1287 mA 298 mA 259 mA 1304 mA 309 mA Note: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal pattern or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher.Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) ©2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice.Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co. Simplex.and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are "registered trademarks of the National Fire Protection Association(NFPA). S4906-0011 Rev.410/2018 • • Simplex System Accessories UL Listed* 4081 Series End-of-Line Resistor Harnesses Features For use as Class B end-of-line resistor: • Connect these resistor harnesses where end-of-line resistors are required at remote locations to monitor wiring continuity • Refer to specific circuit specifications for end-of-line resistor requirements UL Listed to Standard 864 Product Selection -9-1/2" (241 mm) Model Reference Description** Number 4081-9001 733-892 2.2 kU, 1/2 W 4081-9002 733-893 3.3 kc2, 1 W 4081-9003 733-896 4.7 kl, 1/2 W 4081-9004 733-886 6.8 kS2, 1/2 W 4081-9005 733-984 1.8 kS2, 1/2 W 4081-9006 733-890 560 S2, 1 W 4081-9007 733-891 1.2 kf1, 1 W 4061»9OO 733-894 10 la 1/2 W 4081-9009 733-912 20 0, 1 W V 4081-9010 733-973 1 kO, 1 W 4081-9011 733-974 100 S2, 1/2 W 4081-9012 733-985 22 k4, 1/2 W Typical 4081 Series Resistor Harness Assembly 4081-9013 734-086 4.99 kS), 1/2 W,± 1% (full size except for lead length) 4081-9014 734-092 2.4 kS2, 1/2 W 4081-9015 734-093 1.5 kf, 1/2 W 4081-9016 734-149 150 kn, 1/2 W Specifications 4081-9017 734-171 3.9 kS2, 1 W 4081-9018 734-168 10 kS2, 1 W Overall Length Approximately 9-1/2"(241 mm) Wire Length 7"(178 mm)± 1"(25 mm) **±5%tolerance except as noted. s Wire Size 18 AWG(0.82 mm2) Insulation 600 V, black Leads Stripped 0.5"(13 mm);tinned Resistor Resistor leads are crimped to wires Attachment and covered with heat shrink tubing *This product was not approved by ULC,FM,MEA(NYC),or CSFM as of document revision date.Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4081-0003 7/2004 ®Simplex TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC)Acceptance* Non-Addressable, SmartSync Operation Compatible Features Visible only(V/O)24 VDC notification appliances with high output xenon strobe, available for wall LII. or ceiling mount: . • Intensity is selectable as 15,30,75,or 110 candela with ',. , visible selection jumper secured behind strobe housing , • Operation is compatible with ADA requirements(refer to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity,supervised notification appliance circuit(NAC) • Regulated circuit design ensures consistent flash output Wall Mount Strobes and provides controlled inrush current • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens • Listed to UL 1971 and ULC S526 J I � J I. Strobes provide synchronized flash for use with: • Simplex®fire alarm control panels with NACs selected Ceiling Mount Strobes to provide strobe synchronization or SmartSync two-wire control Descri•tion • 4009 IDNet NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules(SCMs)that resistant and provide a convenient strobe intensity • provide Class B or Class A output from conventional selection.Since each model can be selected for intensity NAC inputs output,on-site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi-flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens)that mounts to a single or double gang,or • Wall mount strobes easily mount to single gang,double 4"square standard electrical box.The cover can be gang,or 4-inch square outlet box quickly removed(a tool is required)and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection,and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation,a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity.An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975-9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes* Proper selection of visible notification is dependent on occupancy,location,local codes,and proper applications of:the National Fire Alarm Code(NFPA 72),ANSI • Refer to page 2 for guard listing.This product has been approved by the California State A 1 17.1;the appropriate model building code:BOCA, Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7125.0026:316 for allowable values and/or conditions concerning ICBO,or SBCCI;and the application guidelines of the • material presented in this document.Refer to page 2 for listing status of wire guards. Americans with Disabilities Act(ADA). Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4906-0001-5 11/2014 Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their SmartSync two-wire control is available from: reflections can be seen from one location,synchronized • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, flashes reduce the probability of photo-sensitive reactions and 4100U Fire Alarm Control Panels(refer to as well as the annoyance and possible distraction of individual product data sheets for more information) random flashing.These multi-candela strobes are • 4009 IDNet NAC Extenders(refer to data sheet synchronized over a two-wire circuit when connected to 54009 0002) compatible NACs,to compatible Synchronized Flash Modules,or to SmartSync Control Modules. • SmartSync Control Module(SCM)Model 4905-9938 (refer to data sheet S4905-0003) SmartSync Two-Wire Control Additional SmartSync compatible notification Some applications desire the audible notification appliances include separate horns and combination appliances to be capable of being silenced before the horn/strobe notification appliances. alarm condition is reset(on-until-silenced)while the visible notification appliances are kept activated until the alarm condition is reset(on-until-reset). SmartSync operation mode provides this function using a single circuit(two-wire operation). Product Selection Multi-Candela Visible Notification Appliances(Strobes) Model Mounting Housing Color "FIRE"Lettering Description 4906-9101 Wall Red White 4906-9103 White Red Multi-candela strobe with intensity selectable as: 15,30,75,or 110 candela;synchronized flash rate; 4906-9102 Red White SmartSync two-wire control compatible — 0' Ceiling 4906-9104 White Red Wall Mount Strobe Adapters Model Description Dimensions • 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm) 5-3/8"H x 5-1/4"W x 1-5/8"D deep surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7 7/8"x 5-1/8"x 2 3/4"D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate;zinc plated; required for mounting to 4-7/8"x 3-1/8"x 0.060"D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules(refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with 1-3/8"x 2-7/16"x 13/16" in/out 18 AWG(0.82 mm2)wire leads,rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905 9938 SmartSync Control Module with Class B or Class A output;mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D For Wall mount strobes 4905-9993 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4905-9961* Wall mount 6-1/16"H x 6-1/16"W x 3-1/8"D Red wire guard with mounting plate,compatible with (154 mm x 154 mm x 79 mm) semi-flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8"deep 4905-9926* Ceiling mount (156 mm x 111 mm x 73 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0001-5 11/2014 Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC;see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122° F(0°to 50°C) Humidity Range 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC'- 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC; 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting /�� (T �Th Mountingc is compatible with f o 0 \ single gang,double gang,and �i 4"(102 mm)square boxes, /111Mo o 1-1/2"(38 mm)deep,by others � A °O� , J ,__i-o-LI IMPORTANT!WALL MOUNT 1111 INSTALLATION HEIGHT REFERENCE 11 o _�- Bottom of lens J THE ENO _ is either even 13 -+ O UP ` Q with,or slightly Electrical Wiring access hole /�` s'i� s - above bottom box outline - -®tZt� o boxes Wiring terminals b © e — of �0 1 1 Mounting Holes: _ 4"square(4) NFPA 72 requires 80"(2.03 m) �"'°00vpQ 446' ,, , Single gang(2) that the entire lens minimum 0 v Double gang(3) be not less than 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only I is I V from rear of housing; 1] on E factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-5 11/2014 Ceiling Mount Strobe Installation Reference Handy box,1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang • V5744S)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others Also can be attached to boxes .k ,GI/ mounted to drop ceiling T-bar with clips(ERICO No.512 or equal) 0 0 4905-9910 Adapter Plate,required for surface mount with handy box unless using the 4905-9926 wire guard i- I I -1 �, - ' y Ceiling mount strobe F�I J O Optional 4905-9926 wire guard 1 D with mounting plate Strobe intensity / viewing slot i 7„ - ;.1� , ...,Intensity selection plug, i accessible only from rear of lens i J housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt o and Optional Wire Guard -Mn Surface mount conduit and '-a.O box shown for reference�.. = 4"(102 mm)square .- —r 71 lilii11==ITAIliiil t �...r„ a�nr� ' box profile, mlm)1de/ep i IIiIIII.I.I.IuII 1 II I%1�.L ��' O O ii Optional 4905-9961 FciLW1 1 NM► I Wire Guard --_- Strobe ' D -�I' 4905-9931 Adapter Plate (� I =l Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). SoS i m p 1 EX Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0001-5 11/2014 www.simplex-fire.com ©2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice.