Permit CITY OF TIGARD MASTER PERMIT
4 ii
1 ' I '''' COMMUNITY DEVELOPMENT Permit#: MST2022-00332
Date Issued: 09/20/2022
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1 S135DB05400
Jurisdiction: Tigard
Site address: 11390 SW 94TH AVE
Subdivision: MILLER Lot: 1, PLUS PT VACAT
Project: Bales
Project Description: Solar PV system 5.7 kW, 2 circuits.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $8,265.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Roof top solar array 5.7 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
BALES,MARY ELIZABETH& ION DEVELOPER LLC Required Items and Reports(Conditions)
TERRY VERN 3214 NORTH UNIVERSITY AVE
11390 SW 94TH AVE 503
TIGARD,OR 97223 PROVO,UT 84604
PHONE: PHONE: (888)781-7074
FAX:
Total Fees: $457.42
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
Qc9_nn'I_nnln thrnnnh()AR QF9_M1_MQn Yoi_�mat/nktain nnv of tK'q r,,lac nr riirart rn,octinnc to rll IMC by Tallinn Fn3 939'IQR7 nr 1 Rnr13'39 7'24.4
Issued By:�T� '— -------- Permittee Signature: _ —" ___________
'-c irS03.639.4175 by 7:00 a.m.for available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
I
Building Permit Application '
RECEIVE P� # '-
Residential FOR OFFICE USE ONLY
Ci of Ti and Uri 6 2022 Received Permit No.:e,,,
`,• g Date/By: MS1fZz—0033Z-
13125 SW Hall Blvd.,Tigard,OR 97223 CIGARD Plan Review
IF 1 = Phone: 503.718.2439 Fax: 503.598.1960TM OF�� Date/By: i3 ?/2 it Other Permit:
T 1 G AK D Inspection Line: 503.639.4175 'LING DP W Date Ready/By: / Juris: ® See Page 2 for
Internet: www.tigard-or.gov Notified/Method: 9 ( /ZZ *I Supplemental Information
TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
CI Addition/alteration/replacement Other: PV Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
1-and 2-family dwelling ❑Commercial/industrial Valuation: $ $ 265
ElAccessory building El Multi-familyNumber of bedrooms:
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION x Total number of floors:
IX/ Job site address: 11390 Southwest 94th Avenue New dwelling area: square feet
City/State/ZIP: Tigard, Oregon, 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Bales Solar Install Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Miller Lot no.: 1 Permit fees*are based on the value of the work performed.
Tax map/parcel no.: 1 S 135DB05400/ R276098 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of solar panels on existing residential roof. Valuation: $
5.7 kW. Addition of 2 0-30A circuits. Existing building area: square feet
New building area: square feet
SI PROPERTY OWNER ❑ TENANT Number of stories:
Name: Terry Bales Type of construction:
Address: 11390 Southwest 94th Avenue Occupancy groups:
City/State/ZIP: Tigard, Oregon, 97223 Existing:
Phone:( 503)639-4560 Fax:( ) New:
• APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
Business name: ION DEVELOPER LLC (Please refer ro fee schedule)
Structural plan review fee(or deposit):
Contact name: Dustin Davidson
FLS plan review fee(if applicable):
Address:4801 N University Ave#900
City/State/ZIP: Provo, UT 84604 Total fees due upon application:
Amount received:
Phone:( 888) 781-7074 Fax::( )
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail: permits@ionsolar.com
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System.
Business name: ION DEVELOPER LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 4801 N University Ave#900 Solar Installation Specialty Code checklist.
City/State/ZIP: Provo, UT 84604 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( 888) 781-7074 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.: 230394 Total fee due upon application: $201.60
Authorized signature: Dustin This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
*Fee methodology set by Tri-County Building Industry
Print name: Dustin Davidson Date:8/11/2022 Service Board.
I:\Building\Pennits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit Application FOR OFFICE USE ONLY
CI o Tl and Received
_ �J f g DateB : • RM I h
IMI
a 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#:
Inspection Line: 503.639.4175 Ready Date/By: Juris: ® See Page 2 for
T I GA R D1. Internet: www.tigard-or.gov Notified/Method: Supplemental Information
TYPE OF WORK PLAN REVIEW
❑New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
❑Service or feeder 400 amps or more 0 Building over three stories.
❑Demolition 1. Other: PV Solar where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
• 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family 0 Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address: 11390 Southwest 94th Avenue I00HP or more. ❑"A","E","l-2 "1-3",
City/State/ZIP: Tigard, Oregon, 97223 0 Six or more residential units. occupancy.
tytate g , g 0 Recreational vehicle parks.
❑Health-care facilities.
Suite/bldg./apt.#: Project name: Bales Solar Install 0 Hazardous locations. 0 Supply voltage for more than
0 Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Qty. I Each I Total I *
New residential single-or multi-family dwelling unit.
Subdivision: Miller Lot#: 1 Includes attached garage.
1,0Tax map/parcel#: 1 S 135DB05400/R276098 Eaa..add'l0 sq.ft.or less 168.54 4
500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
75.00 2
Installation of solar panels on existing residential roof.
(with above sq.ft.)
Limited energy,multi-family 75.00 2
5.7 kW. Addition of 2 0-30A circuits. residential(with above sq.ft.)
Renewable Energy 0 See Page 2
• PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation
Name: Terry Bales 200 amps or less 100.70 2
Address: 11390 Southwest 94th Avenue 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP: Tigard, Oregon, 97223 601 amps to 1,000 amps 301.04 _ 2
Phone:( 503) 639-4560 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: mishabales@outlook.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
APPLICANT D CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name: ION DEVELOPER LLC above service or feeder fee, 7.42 2
each branch circuit
Contact name: Dustin Davidson B.Fee for branch circuits without
service or feeder fee,first
Address: 4801 N University Ave#900 branch circuit 1 56.18 56.18 2
Each add'l branch circuit 1 7.42 7.42 2
City/State/ZIP: Provo, UT 84604 Miscellaneous(service or feeder not included)
Phone:(888) 781-7074 Fax: :( ) Each manufactured or modular
dwelling,service and/or feeder 67.84 2
Email: permits@ionsolar.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name: ION DEVELOPER LLC Sign or outline lighting 67.84 2
Address: 4801 N UniversityAve#900 Signaln c alteration,)or extension. 0 See Page 2 2
panel, or extension.
City/State/ZIP: Provo, UT 84604 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(888) 781-7074 Fax:( ) Investigation(1 hr min) 90.00/hr
Email: Industrial plant(1 hr min) 78.18/hr
permits@ionsolar.com Inspections for which no fee is
CCB Lie.: 230394 Electrical Lic.: C1524 Suprv.Lie.: 6098S specifically listed(%hr min) 90.00/hr
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: .jaw#B e►,f! Subtotal: 197.16
Print name: David S Conrad Date: 8/11/2022 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
�r'f �0ic ''0 TOTAL PERMIT FEE:
Authorized signature: °
This permit application expires if a permit is not obtained within 180
Print name: Dustin Davidson Date: 8/11/2022 days after it has been accepted as complete.
* Number of inspections allowed per permit.
1:\Building\Permits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Description I Qty. I Each I Total I *
Fee for all residential systems combined: $75.00
3' Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 133.56 2
n A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
n B• urglar Alarm 25.01 to 50 kva 301.04 2
n G• arage Door Opener* 50.01 to 100 kva 552.26 2
>100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
n V• acuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
7 Other: Each additional inspection is 66.25/hr 1
charged at an hourly(I hr min)
Inspections for which no fee is
specifically listed(1/2hr min) 90.00/hr
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): 133.56
* Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
n Boiler Controls
n C• lock Systems
Data Telecommunication Installation
❑ Fire Alarm Installation
n H• VAC
❑ Instrumentation
n Intercom and Paging Systems
n Landscape Irrigation Control*
n Medical
n N• urse Calls
❑ Outdoor Landscape Lighting*
n P• rotective Signaling
n Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:ABuilding\Permits\ELCPermilApp_ELR_ERE.doc Rev 06/17/2015