Report (5) OFFICE COPY RECEIVED BTF Installations LLC JU N x 2022 23150 S Viola Welch Rd CITY OF TIGARD Beavercreek OR 97004 BUILDING DIVISION 971-371-6183 Regarding Jones Golf at 7250 SW Durham Rd Tigard OR 97224lP2022-oC(' 111 They storing Nylon bags class IV materials per NFPA Fire extinguishers will be installed every 75' of travel /Z90 (bur41 b The aisles will be 5' or greater. The product will not be encapsulated There will be no solid decking The product/ piles are stable The materials will be stored to 18' high top of product. There are single and double row racks with no multiple rows of racks Per NFPA 16.2.1.3.2 D curve G Class IV product stored to 20' high with less than 8' aisles requires .58GPM /2000 sqft Apply figure 16.2.1.3.4.1 at 18' top of product .58 X .80= .464 GPM /2000SQFT The existing sprinkler system is at .475/2000 and will meet the NFPA codes. Please call with any q uestions. Thank You Brian Ferrick 971-371-6183 Chapter 5 • Classification of Occupancies and Commodities 114 TABLE A.5.6.3 Continued T4 Product Heading Product NFPA 13 Pr Powders/Pills Pharmaceutical pills;glass bottles or jars;cartoned Class II Pharmaceuticals pills;plastic bottles or jars;cartoned Class IV _ Polyvinyl Alcohol(PVA)resins;bagged Class IV V Powders;combustible(ordinary such as sugar or flour);free-flowing;bagged Class II Powders;noncombustible free-flowing powdered or granular materials(cement, Class I calcium chloride,clay,iron oxide,sodium chloride,sodium silicate,etc.) Powders;noncombustible;glass bottles or jars;cartoned Class I • Powders;noncombustible;PET bottles or jars Class II Powders;noncombustible;plastic(other than PET)bottles or jars;uncartoned Group A Nonexpanded Powders;noncombustible;plastic bottles or jars greater than 1 gallon(4 L) Group A Nonexpanded 5. capacity ;, m Powders;noncombustible;plastic bottles or jars up to 1 gallon(4 L)capacity; Class IV (1 cartoned ( Textile Materials/ Cloth;natural fibers;baled Class III Products Cloth;synthetic cloth Class IV (= Clothing;natural fibers(e.g.,wool,cotton)and viscose Class III Cotton;cartoned Class Diapers;cotton or linen Class III Diapers;plastic or nonwoven fabric;cartoned Class IV Diapers;plastic or nonwoven fabric;plastic-wrapped;uncartoned Group A Nonexpanded /Fabric;rayo , ; Class IV Fabric;synthetic(except rayon and nylon);greater than 50/50 blend Group A Nonexpanded , Fabric;synthetic(except rayon and nylon);up to 50/50 blend ' Class III Fabric;vinyl-coated(e.g.,tablecloth);cartoned Group A Nonexpanded Fibers;rayon and nylon;baled Class IV Fibers;synthetic(except rayon and nylon);baled Group A Nonexpanded Thread or yarn;rayon and nylon;wood or paper spools Class IV Thread or yarn;rayon or nylon;plastic spools Group A Nonexpanded Thread or yarn;synthetic(except rayon and nylon);greater than 50/50 blend; Class N paper or wood spools Thread or yarn;synthetic(except rayon and nylon);greater than 50/50 blend; Group A Nonexpanded plastic spools Thread or yarn;synthetic(except rayon and nylon);up to 50/50 blend;plastic spools Group A Nonexpanded Thread or yarn;synthetic(except rayon and nylon);up to 50/50 blend;wood or Class III paper spools Wax Products Candles Group A Expanded Paraffin or petroleum wax;blocks Group A Expanded Wire/Cable/Spools Spools;plastic;empty Group A Nonexpanded Spools;wood;empty Class III Wire or cable;PVC insulated;metal or wood spools Class II , Wire or cable;PVC insulated;plastic spools Class IV. Wire;bare;metal spools,uncartoned Class I Wire;bare;metal spools;cartoned Class II Wire;bare;plastic spools;cartoned Class IV 2016 Automatic Sprinkler Systems Handbook Copyright 2017 National Fire Protection Association(NFPA).Licensed,by agreement,for individual use and download on 04/1612017 to Brian Ferric(for designated user Brian Ferric(.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized use,contact licensing@nfpe.org. PROTECTION OF RACK STORAGE OF CLASS I THROUGH CLASS IV COMMODITIES 13-175 Ceiling sprinkler density(mm/min) N Curve Legend Curve Legend 6.1 8.2 10.2 12.2 14.3 16.3 18.3 20.4 E S 4000 370 o A-8 ft(2.4 m)aisles with C-4 ft(1.2 m)aisles with •. m high-temperature ceiling high-temperature ceiling El. `m sprinklers and ordinary- sprinklers and ordinary- o A - B C-D o temperature in-rack temperature in-rack 3000 280 a. sprinklers sprinklers .c \ \\ -� a 8-8 ft(2.4 m)aisles with D-4 ft(1.2 m)aisles with \ ordinary-temperature ordinary-temperature rn 2000 186 a) ceiling sprinklers and ceiling sprinklers and O o ordinary-temperature ordinary-temperature ag in-rack sprinklers in-rack sprinklers c 1000 93 c •°-,' 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 y' O Ceiling sprinkler density(gpm/ft2) 00 FIGURE 16.2.1.3.2(f) Single-or Double-Row Racks-20 ft(6.1 m)High Rack Storage- Sprinider System Design Curves-Class III Encapsulated Commodities-Conventional Pallets. 465 N Curve Legend Curve Legend Ceiling sprinkler density(mm/min) E c o A-8 ft(2.4 m)aisles with C-4 ft(1.2 m)aisles with O 10.2 12.2 14.3 16.3 18.3 20.4 22.4 24.5 high-temperature ceiling high-temperature ceiling al 4000 370 w sprinklers and ordinary- sprinklers and ordinary- oa temperature in-rack temperature in-rack m A B C D m sprinklers sprinklers Sc 3000 280 28-8 ft(2.4 m)aisles with D-4 ft(1.2 m)aisles with c c 'Q a ordinary-temperature ordinary-temperature a \ N ceiling sprinklers and ceiling sprinklers and 02000 \s.. 186 15 ordinary-temperature ordinary-temperature aas d in-rack sprinklers in-rack sprinklers m m c c .N 1000 93 •N 0 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0 Ceiling sprinkler density(gpm/ft2) FIGURE 16.2.1.3.2(g) Single-or Double-Row Racks-20 ft(6.1 m)High Rack Storage- Sprinkler System Design Curves-Class IV Encapsulated Commodities-Conventional Pallets. Table 16.2.1.3.2 Single-or Double-Row Racks-Storage Height Over 12 ft(3.7 m)Up to and Including 25 ft(7.6 m) Ceiling Sprinkler Water Demand Aisles* With In-Rack Sprinklers Without In-Rack Sprinklers APPly Sprinklers Apply Figure Commodity Mandatory Figure 16.2.1.3.4.1 Height Class Encapsulated ft m In-Rack Figure Curves 16.2.1.3.4.1 Figure Curves 4 1.2 CandD 1621.32(a) F and H No No 16.2.1.3.2(a) Yes 8 2.4 A and B EandG I 4 1.2 C and D 16,2.1.3.2(e) G and 11 Yes No 16.2.1.3.2(e) ' Yes 8 2.4 A and B E and F 4 1.2 C and D G and H No No 16.2.1.3.2(b) 16.2.1.3.2(b) Yes 8 2.4 A and B EandF fI Overt 2 ft 4 1.2 C and D Gand H (3.7 m)up Yes 8 2.4 No 16.2.1.3.2(e) A and B 16.2.1.3.2(e) E and F Yes to and Yes including 4 1.2 C and D G and H 20 ft(6.1 m) No No 16.2.1.3.2(c) 16.2.1.3._9(c) Yes 8 2.4 AandB EandF 111 4 1.2 C and D Yes I level 16.2.1.3.2(t) - - - . 8 2.4 A and B 1.2 CandD No (6.2.1.3.2(d) 8 2.4 AandB EandF 4 1.2 C and D Yes 1 level 16.2.1.3.2(g) - - - 8 2.4 Aanda (continues) 2016 Edition Copyright 2017 National Fire Protection Association(NFPA).Licensed,by agreement,for individual use and download on 04/16/2017 to Brian Ferrick for designated user Brian Ferrick.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized use,contact Licensing@nfpa.org. • 13-174 INSTALLATION OF SPRINKLER SYSTEMS Curve Legend Curve Legend Ceiling sprinkler density(mm/min) N A-Single-or double-row racks E-Single-or double-row racks = E with 8 ft(2.4 m)aisles with 8 ft(2.4 m)aisles 8.2 10.2 12.2 14.3 16.3 1$$8.3 20.4 22.4 24.5 c with high-temperature and high-temperature o 4000 I e I n ' 370 o ceiling sprinklers and ceiling sprinklers a Single point - E ordinary-temperature F-Single-or double-row racks a design only o in-rack sprinklers with 8 ft(2.4 m)aisles o 4 - B D -E ---i F a H o B-Single-or double-row racks and ordinary-temperature • 3000 `\`% . \\ ` 280 9 N \\ ` Ntl, with 8 ft(2.4 m)aisles ceiling sprinklers `\ with ordinary-temperature G-Single-or double-row racks 86 a 2000 1 a. ceiling sprinklers and with 4 ft(1.2 m)aisles o C G - o ordinary-temperature and high-temperature A in-rack sprinklers ceiling sprinklers E E C-Single-or double-row racks H-Single-or double-row racks a 1000 93 c with 4 ft(1.2 m)aisles or with 4 ft(1.2 m)aisles .ao-,' 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 •°-,' multiple-row racks with and ordinary-temperature a a high-temperature ceiling ceiling sprinklers Cl Ceiling sprinkler density(gpm/ft2) o sprinklers and ordinary- temperature in-rack Note:Curves C and D also apply to ceiling sprinklers only for multiple-row sprinklers rack storage up to and including 15 ft(4.6 m)high,and Figure 16.2.1.3.4.1 D-Single-or double-row racks shall not be applied. with 4 ft(1.2 m)aisles or s multiple-row racks with Zr?r ordinary-temperature ceiling sprinklers and ordinary-temperature in-rack sprinklers rinkler System Design Curves-20 ft(6.1 m)High Rack Storage- IV None psulated Commodities-Conventional Pallets. Curve Legend Curve Legend A-8 ft(2.4 m)aisles with E-8 ft(2.4 m)aisles with high-temperature ceiling high-temperature ceiling sprinklers and ordinary- sprinklers temperature in-rack F-8 ft(2.4 m)aisles with sprinklers ordinary-temperature Ceiling sprinkler density(mm/min) N B-8 ft(2.4 m)aisles with ceiling sprinklers v E ordinary-temperature ceiling G-4 ft(1.2 m)aisles with 6.1 8.2 10.2 12.2 14.3 16.3 18.3 20.4 H sprinklers and ordinary- 4 4000 I /'- 370 0 high-temperature ceiling 'o Single point- temperature in-rack sprinklers iu design only= o) sprinklers H-4 ft(1.2 m)aisles with o A - 8+C- D !:a-,' C-O ft(1.2 m)aisles with ordinary-temperature .- 3000 280 d high-temperature ceiling ceiling sprinklers Se 3 sprinklers and ordinary- o ���\ \ _C, Q temperature in-rack ° 2000 ° sprinklers 0 186 o D-4 ft(1.2 m)aisles with a a ordinary-temperature ceiling f° 1000 a sprinklers and ordinary- c 93 c temperature in-rack • 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 •6 sprinklers o Ceiling sprinkler density(gpm/ft2) Cl FIGURE 16.2.1.3.2(e) Single-or Double-Row Racks-20 ft(6.1 m)High Rack Storage- Sprinkler System Design Curves-Class I and Class II Encapsulated Commodities-Conventional Pallets. 2016 Edition Copyright 2017 National Fire Protection Association(NFPA).Licensed,by agreement,for individual use and download on 04/16/2017 to Brian Ferrick for designated user Brian Ferrick.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized use.contact licensing@nfpa.org. PROTECTION OF RACK STORAGE OF CLASS I THROUGH CLASS IV COMMODITIES 13-179 3.7 Height of storage(m) eluding 25 ft (7.6 m) in Height Protected by Control Mode 175 3.0 V 4.6 6.1 7.6 9.1 10.7 Density/Area Sprinklers at the Ceiling. 16.2.1.4.2.1* Maximum horizontal spacing of in-rack sprin- klers in single-or double-row racks up to and including 25 ft 150 (7.6 in) in height shall be in accordance with Table 16.2.1.4.2.1. 16.2.1.4.2.2* Maximum horizontal spacing and maximum at125 area of coverage of in-rack sprinklers on branch lines, in '9 multiple-row racks with storage up to and including 25 ft z (7.6 m) in height, shall be in accordance with Table a 100 16.2.1.4.2.2. r= m .a (A) The rack plan view shall be considered in determining 75 Ts the area covered by each sprinkler. 0 60 _ _ (B) The aisles shall not be included in area calculations. a 50 16.2.1.4.2.3*The elevation of in-rack sprinkler deflectors with respect to storage shall not be a consideration in single- or double-row rack storage up to and including 20 ft (6.1 m) 25 high. (See Section C.16.) 16.2.1.4.2.4*In single-or double-row racks without solid shelves 0 j with storage over 20 ft(6.1 m)high,or in multiple-row racks,or 0 10 12 15 640 25 30 35 in single- or double-row racks with solid shelves and storage Height of storage(ft) height up to and including 25 ft (7.6 m), a minimum of 6 in. /jg 7`, lv=AV‘II (150 mm)vertical clear space shall be maintained between the FIGURE 16.2.1.3.4.1 Ceiling Sprinkler Density vs. Storage in-rack sprinkler deflectors and the top of a tier of storage. Height. (A) Sprinkler discharge shall not be obstructed by horizontal rack members. 16.2.1.4.2.5 For multiple-row racks, a minimum of 6 in. (A) The percentage shall be applied to the density deter- (150 mm) shall be maintained between the in-rack sprinkler mined in accordance with 16.2.1.3.4. deflector and the top of a tier of storage. (B) The increase in density shall not apply where in-rack (A) Sprinkler discharge shall not be obstructed by horizontal sprinklers are utilized in the design. rack members. ' 16.2.1.4 In-Rack Sprinklers for Rack Storage of Class I 16.2.1.4.2.6 Sprinklers installed in racks shall be spaced with- Through Class IV Commodities Stored Up to and Including out regard to rack uprights. (See Section C.17.) 25 ft(7.6 m)in Height Protected with Control Mode Density/ Area Sprinters at Ceiling. 16.2.1.4.3 In-Rack Sprinkler Water Demand for Rack Storage of Class I Through Class IV Commodities Stored Up to and 16.2.1.4.1 In-Rack Sprinkler Location for Rack Storage of Including 25 ft(7.6 m)in Height Protected by Control Mode Class I Through Class IV Conunodities Stored Up to and In- Density/Area Sprinklers in the Ceiling.See Section C.18. eluding 25 ft(7.6 m)in Height. 16.2.1.4.3.1 The water demand for sprinklers installed in 16.2.1.4.1.1 In single-or double-row racks,in-rack sprinklers racks shall be based on simultaneous operation of the most shall be installed in accordance with Table 16.2.1.3.2. hydraulically remote sprinklers as follows: 16.2.1.4.1.2 In multiple-row racks no deeper than 16 ft (1) Six sprinklers where only one level is installed in racks (4.9 m)with aisles 8 ft(2.4 m) or more in width,in-rack sprin- with Class I,Class II,or Class III commodities klers shall be installed in accordance with Table 16.2.1.3.3.1. (2) Eight sprinklers where only one level is installed in racks 16.2.1.4.1.3 In multiple-row racks deeper than 16 ft (4.9 m) with Class IV commodities or with aisles less than 8 ft(2.4 m)wide,in-rack sprinklers shall (3) Ten sprinklers (five on each two top levels) where more be installed in accordance with Table 16.2.1.3.3.2. than one level is installed in racks with Class I,Class II,or Class III commodities 16.2.1.4.1.4 In-rack sprinklers at one level only for storage up (4) Fourteen sprinklers(seven on each two top levels)where to and including 25 ft(7.6 m) high shall be located at the first more than one level is installed in racks with Class IV tier level at or above one-half of the storage height. commodities 16.2.1.4.1.5 In-rack sprinklers at two levels only for storage 16.2.1.4.4 In-Rack Sprinkler Discharge Pressure for Rack up to and including 25 ft(7.6 m) high shall be located at the Storage of Class I Through Class IV Commodities Stored Up first tier level at or above one-third and two-thirds of the stor- to and Including 25 ft(7.6 m)in Height Protected byControl age height. Mode Density/Area Sprinklers at thehCeiling. Sprinklers in 16.2.1.4.2 In-Rack Sprinkler Spacing for Rack Storage of racks shall discharge at not less than 15 psi (1.0 bar) for all Class I Through Class IV Commodities Stored Up to and In- classes of commodities. (See Section C.19.) a 1. 2016 Edition