Loading...
HomeMy WebLinkAboutReport ms-r 2023- 001 oz. 'FIVE . City of Tigard 1 „R z / 2023 114 '' Building Division CITY OF TIGARD • 13125 SW Hall Blvd,Tigard, OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 15315 SW Alderbrook Dr City: Tigard Zip: 97224 Owner's Name: Richard Garber Date: 3/21/23 Contractor's Name: Blue Sky Solar CCB #: 223739 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ,' No OSSC or ORSC for desk requirements. Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "c"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes .er Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/Photo V oltaic-Checklist02.01-11.docx Is the construction Yes material wood and does Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. 12. Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. E Yes the prescriptive path. E No Is the combined weight o Yes of the PV modules and If"Yes", qualifies for racking less than or E No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? 0 Metal Single layer If roofing material is Roofing Check the type of 0 of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. of composition shingle. Is the roof mounted /Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for to the roof framing or blocking ❑ No the prescriptive path. directly? 2 t113uilding/Fortes/PhotoVoltaic-ChecklistD2-01-11.docx Is the gauge 26 or less? If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for S Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for rde fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/"thickness, Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. r No 3 I:fBui I dingfForms/PhotoVoltaic-Checkl ist02-01.11.doex Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: Listing Agency: REC Solar/ Blue Sky Installing 4 I:Building/Forms/PhotoVoltaic-Checklist02.01-11.docx W .SSUNG RECEIVED • �+• MAR 2 / 2023ONSULTING 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE CITY OF TIGARD office (201) 874-3483 Gregory T. Elvestad, PE BUILDING DIVISI,flgfssling@wysslingconsulting.com March 16, 2023 Blue Sky Solar LLC 1550 West Gordon Avenue Layton, UT 84041 Re: Engineering Services Garber Residence 15315 Southwest Alserbrook Drive, Tigard, OR 6.000 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses at 24" on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slope: 20 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load = 36 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 96 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2022 Oregon Structural Specialty Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. •Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Unirac installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16" lag screw is 298 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2'/2", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 2'%"embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48" on centers. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2022 Oregon Structural Specialty Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, 4, '•-9 0 ,- ��D PROFF Scott E. Wy--i g, • �5� %NF ' S'i,,a ` Oregon Li, nse • •'•:01 1/ 'Ec . c /i, °rr E. wr55`•` Signed: 3/16/2023