Specifications OlSr L(J 23'. 5°5 RECEIVEDION Solar 4801 N University Ave.Suite 900 ION FFR 2 1 2023 Provo, UT 84604 luke.rowley@ionsolar.com CITY OF TIGARD BUILDING DIVISION Monday, February 13,2023 RE: Rick M Barde Residence-9568 Southwest North Dakota Street,Tigard, Oregon To Whom It May Concern: I have evaluated the roof structural elements of the residence for the required design loads and the additional load that will be imposed by the proposed solar system.The existing roof information was provided by a site visit by an audit team at ION Solar. Based on that site visit, it is my understanding that the roof framing information is as follows: Roof Structure: Pre-Manufactured Wood Trusses with 2x4 Top Chords @ 24"O.C. Roofing Material: Composition Shingle The Required codes and loads are as follows: Codes: 2019 OSSC,2021 ORSC Risk Category: II Wind Speed (3-Sec Gust, MPH): 96 Exposure Category: B Ground Snow Load(psf): 36 Roof Snow Load(psf): 26 Roof Live Load(psf): 20 (superseded by roof snow load) After reviewing the existing roof framing information and in accordance with the structural calculations on sheet S-5 which were performed according to the applicable codes and loads above,it is my recommendation that the existing roof framing is adequate to safely and sufficiently support the required structural design loads and the weight of the new solar system as is.Alteration or replacement of existing structural elements is not required. This evaluation only applies to the areas of the roof that will be directly supporting the solar system and does not make any recommendations for any other structural components of the building.The racking must be installed per the manufacturer's recommendations. - The 5/16"x 3-1/2"zinc plated steel lag screw used to attach the solar system to the roof must be staggered to evenly distribute the loads over the affected area and must penetrate the truss top chords with a minimum embedment depth of 2.5" .— j PROF£S ��� G I Nf SRO THIS LETTER VOID UNLESS STAMPED Sincerely, 4.4� `� F/ A. Luke Rowley,PE /� 9 950P l OREGON 9(gN'ROw\5 02/15/2023 EXPIRES:12/31/24 . 1 . tiECEIVED FFB 2 1 2023 CITY OF TIGARD BUILDING DIVISION ••• ••••• SILFAB PRIME • • •SILFAB • SOLAR` SIL-400 HC+ RELIABLE ENERGY. DIRECT FROM THE SOURCE . PROUD PARTNER Designed to outperform. Dependable, durable, high-performance ION solar panels engineered for North American homeowners. SILIABSOLAR.COM C E ❑ Eta ® I Ec ELECTRICAL SPECIFICATIONS 400 Test Conditions STC NOCT - Module Power(Pmax) Wp 400 298 Maximum power voltage(Vpmax) V 36.05 i 33.50 Maximum power current Plumes) A 11.10 i 8.90 Open circuit voltage(Vet) V 43.02 40.35 Short circuit current(Isc) A 11.58 9.34 Module efficiency ,o 20.2% 1 18.8% Maximum systemvoltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp Oho+10 Measurement conditions:SIC 1000 W/m'•AM 1.5•Temperature 25'C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty 5 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics mayvary by±5%and power by 0 re+1DW. MECHANICAL PROPERTIES)COMPONENTS i.. METRIC IMPERIAL Module weight 21.3kg 10.2kg 471hs s0.4lbs Dimensions(H x L x D) 1914mm x 1D36mm 835mm 75.3 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)' 5400 Pa rear load/S400 Pa front load 112.8Ib/It3 rear load/112.81b/fr front load Hail impact resistance a 25 mm at 83 km/h e l in at 51.6 mph Cella 132 Half cells-Si mono PERC i 132 Half cells-Si mono PERC 9 bulbar-83 x 166 min I 9 busbar-3.26 x 6.53 in Glass 3.2mm high transmittance,tempered, 0.126 in high transmittance,tempered. DSM antirellertive coating DSM antireflective coating Cables and connectors(refer to installation manual) 135Dmm,o 5.7mm,MC4 from Staubli 53In,o 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum(Slack) Bypass diodes 3 diodes-3050045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated tTTEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc +0.064%/"C Module product workmanship warranty 25 years" Temperature Coefficient Voc -0.28%/`C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.36%/`C >_97.1%end 1st yr NOCT(t2°C) t91.6%end 12th yr 45"[ a 85.1%end 25th yr Operating temperature 40/+85°C >_82.6%end 30th yr CERTIFICATIONS SHIPPING SPECS UL 61215-1:2017 Ed.1""',IL 61215-2:2017 Ed.1"'",UL 61730-12017 Ed.1"•',UL 61730- Modules Per Pallet 28 or 26(California) 2:2017 Ed.1"*,CSA C22.2961730-1:2019 Ed.Y"',C59 C22.2861730-2:2019 Ed.2'", Product IEC 61215-1:2016 Ed.l'"',IEC 61215-2:2016 Ed.1"',IEC 61730-1:2016 Ed.2"",IEC 61730-2:2016 Ed.2'"',IEC 61701:2020(Salt Mist Corrosion),IEC C2716:2013(Ammonia Pallets Per Truck 32 or 31(California) Corrosion),UL Fire Rating:Type 2,CEC Listing'" Factory I 1509001:2015 Modules Per Truck 832 or 806(California) • A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolaecom. PAN files generated from 3rd party performance data are available for download at:sllfabsolaccomldownlaads. '•" Certification and CEC listing in progress.December2022,expected completion. + ION I T +1888.781.7074 12.1"[307mm] 51.211300mm] 12.1"[307mm] ION50 LA R.COM ` Mounting Hole(x4) SILFAB SOLAR INC. �) • PIl ----.��� _ ) 800 Cornwall Ave L - 0.5�. ( Bellingham WA 98225 USA _ - / [12mm] .1 T+1360.569,4733 .'II info@silfahsola6<om I '--'�., I SILFA 8 sOLAR.COM 3 1 > 1 E E 1770 Port Drive Y \+a E', E 1 E S Burlington WA 98233 USA - m 1.4"[35mm]i L1 ,L.6 ro-I`D Ei 0 ro o y o T+1360.569.4733 Ip t�� _ m co ro 24D Courtneypark Drive East 1. w I E o a Mississauga ON L5T 2V3 Canada 3 E= r+19D5.255.2501 73, 0.06" 53.15" ' 2' F+1905.696.0267 ICI E Cable Lenglh 2 s -SIL-400-H0+-2 02 2111 4 0Uorepnreprnducdon olanykind isallowetl without --DrainageHOIex3 permission.Data and information iisubj u modmaaun:without netlae.9 OM,Solar Inc.,I ) 111 ` awz.ailfabsolar'Is a registered mademaMM J 2.4"[60mm] 8'[200mm] L 1 EN P H AS E DATA SHEET y r• If ENPHASE 10 4. ENPI.ASE {J i De I Pi IIL IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter • Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the Enphase grid is down` • • More than one million cumulative hours of testing year limited warranty • Class II double-insulated Part cf the Enphase Energy System,IQ8 Series 108 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV modules and analysis software. leading limited warranty of up to 25 years. Microgrid-forming u"r CIO • Compllieses with the latest advanced grid support** CERTIFIED • Remote automatic updates for SAFETY the latest grid requirements Connect PV modules quickly and easily to 108 Series IQ8 Series Microinverters are UL Listed as • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. •'IQ8 and IQ8Plus supports split phase,240V I08SP-DS-0002-01-EN-US-2022-03-17 installations only. IQ8 and IQ8+ Microinverters INPUT DATA ICCI 108-60-2-US ID8PLUS-72-2-US Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/12O half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current°[module Ise] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 2OA per branch circuit OUTPUT DATA IACI 108-8C-2-US 108PLUS-72-2-US Peak output power VA 245 300 Max continuous output power vA 240 290 Nominal(L-L)voltage/range° V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency 97 97 Night-time power consumption mw 60 NI EC P.ANICAL DATA Ambient temperature range -40°C to«60°C(-40°F to«140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HiWxD) 212 mm(8.31 x 175 mm(6.91 x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes - Pollution degree PD3 Enclosure Class II double-Insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.1O7.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/module-compatibIlity (2)Maximum continuous input DC current is 1O.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch In your area. IQ8SP-DS-0002-01-EN-US-2022-03-17 I)- EcoFasten For Installers. By Installers. tfr7j CLICKFIT COMPLETE RAIL- BASED RACKING SYSTEM S TA I_ I_ AT I \ JI 1 -_-- REVISION DATE: 03/03/22 VERSION: v2.7 ,7:0,031/01,00312,27j 011," ECOFASTENSOLAR.COM REVISION DATE:03/3/22 VERSION:VI CLICKS 01: EcoFasten INSTALLATION GUIDE _ for Instalffi By Installers. Clicking the page name will take you to that page TABLE OF CONTENTS PAGE 01 FEATURES & BENEFITS PAGE 02 INTRODUCTION PAGE 03 OVERVIEW PAGE 04 COMPONENTS PAGE 05 RATINGS PAGE 06 ARRAY LAYOUT PAGE 07 INSTALLATION PAGE 08 GROUNDING PAGE 17 _ ACCESSORIES PAGE 21 MODULE LIST PAGE 27 CLAMP PART NUMBERS PAGE 36 PAGE 01 REVISION DATE:03/3/22 VER5ON:1 Z7 CLICK 4.„\i, DAC INSTALLATION SUIDE ECOFQStetl For Installers. By Installers. r. - II + III 4.0 C/11 CLICKFIT IX ClickFit conforms to UL 2703 and is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In Rail assembly, the rails can be connected to any of EcoFasten's composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust materials, such as aluminum and coated steel, to ensure corrosion resistance and longevity. ClickFit has been tested in extreme weather conditions including wind,fire, and snow. 1 FEATURES • Tool and fastener free rail attachment • Fully integrated bonding • Click-on Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments PAGE 02 REVISION DAM 03l3/32 VlaION:V2.7 CLICK \\\\X INSTALLATION GUIDE ,Oa EcoFQsten For Installers. By Installers. INTRODUCTION This manual describes the installation of the ClickFit mounting system for photovoltaic modules on steep-slope roofs. Described within are details for composition shingle and tile, attachments for ClickFit System. Other roof types as well as all other installation manuals can be found for download at www. EcoFastenSolar.com. GENERAL INSTALLATION CONDITIONS Failure to observe the requirements in this document can lead to the exclusion of all guarantees and product liability, EcoFasten Solar reserves the right to amend this document without prior notice. STABILITY AND CONDITION OF THE ROOF The roof must be in good condition and strong enough to support the weight of the modules, including the additional equipment, wind and snow loads. When in doubt, consult with the engineer of record, and/or the local building inspector. APPLICATION RANGE OF CLICKFIT Refer to Compatibility module list at the end of this document. Please refer to the Ecofasten ClickFit span tables for system structural certification and allowable spans. WARRANTY Guarantee according to the warranty conditions and general terms and conditions of EcoFasten Solar. These conditions can be found on the website at www. EcoFastenSolar.com. LIABILITY EcoFasten Solar cannot accept any liability whatsoever for damage or injury caused by not taking adequate safety precautions or (accurately)following the instructions given, or resulting from negligence during the installation of the product and any corresponding accessories specified in this document. PAGE 03 REVISION DATE:03/3/21 VERSION:v2.7 CLICK O.A INSTALLATION GUIDE o 1 EcoFasten. For Installers. By Installers. yq ti i \` . \. OVERVIEW The ClickFit mounting system consists of patented adjustable tile hooks and L feet, rails, and the installation materials required for the mounting of photovoltaic modules on composition shingle or tile roofs. For simplicity, tile hooks and L feet will be referred to as "attachments". ATTACHING TO THE ROOF The attachments are fastened to the rafters. Attachments are height-adjustable to level the system on uneven roof surfaces. ATTACHING THE RAIL The rail assembles to the attachments with a click-connector, or Clicker. The rail simply clicks into place without the use of any tools. ATTACHING THE MODULES The modules are attached to the rails by means of mid clamps and end clamps. Installer must review module and any 3rd party manufacturer's documentation for compatibility and compliance with warranty terms and conditions. PAGE 04 REVISION DATE:03A127 VERSION:v2.7 CLICK 0 INSTALLATION GUIDE oOa EcoFasten For Installers. By Installers. SYSTEM COMPONENTS REQUIRED ..`&\ CLICKFIT RAIL RAIL SPLICE TILE HOOK z w z L-FOOT END CAP MID CLAMP C:11) END CLAMP LI SYSTEM COMPONENTS ACCESSORIES • FRAME MLPE MODULE JUMPER MLPE MOUNT MOUNT PAGE Refer to ClickFit Alternate Component Addendum for components not shown 05 REVISION DATE:03/322 VERSION:V2.7 CLICK INSTALLATION GUIDE by4 Eco ' For Installers. By Installers. RATINGS Fire Rating* Class A System Fire Rating Max System Voltage 1500 VDC Max Fuse Rating 40A Certification Conforms to UL STD 2703 Warranty 25 Year Material and Workmanship UL 2703 Markings Product listing label is located on the rail end-caps Roof Pitch 2:12-12:12 UL 2703 Allowable Design Load Rating 10 psf downward,5 psf upward,and 5 psf lateral Max Module Size 25.6 sqft Module Orientation Portrait or Landscape Multiple use Rated Components(Position Independent) Mid Clamp,Frame MLPE Mount and MLPE Mount *Class A System fire rating with Type 1 &2 PV modules.Any module-to-roof gap is permitted,with no skirt required.This rating is applicable with any roof attachment. UL 2703 MARKING EXAMPLE: EcoFasten ETA An ESDEC Company us CLICKFIT SYSTEM Ifl ertek MFG ID CODE:SSS-QQ-YYYY XXXXXXX /V Conforms to UL STD 2703 TORQUE SPECIFICATIONS Component Torque(in-lb) Notes Lag Screw N/A Fully Seat.Use visual indicator of the black EPDM ring around the bonded washer for torquing. Mid-Clamp 144 End-Clamp 96 Rail Clicker Leveling Bolt 142 Pre-torqued upon delivery.Applies to Tile Hook and L-Foot/Clicker Hook Height Bolt N/A Lightly clamp hook to flush with top of next tile row Ground Lug N/A Refer to specific ground lug manufacturer's installation manual MLPE Clip 144 MLPE Mount 144 PAGE 06 RlVWON DATE 0373/72 VELUM 44.7 Nb CLICK INSTALLATIGN GJ E çEcoFasten -./ 4Sk\-14 \ For Installers. By Installers. ell 4 • Refer to span tables, local jurisdiction, or engineer of record specifications when determining setbacks from roof edges, attachment spans, etc. • Mark the perimeter and corners of the array on the roof surface. *Add 3/4" to account for the gap between modules in each direction* • Draw or snap chalk lines where the rails will be installed,(refer to module manufacturer specs to determine allowable mounting locations). • Locate rafters within the area of the array. It may be necessary to shift the array East or West on the roof in order to fall within the rail cantilever specs (1/ 3 of span). • Stagger rafters every row if required by the local jurisdiction, engineer of record, or company policy. PAGE 07 REVISION ME:03/S!]3 YEESION:vL] CLICK INSTALLATION GUIDE oDa ECoFasten °y` " For Installers. By Installers. .A.1.1 \4\s‘ssis 001 \\•I\ s Z ...1/ -- 40040. _ . i,. c:c ., 0 e". 0 J 60.0. jam PRE-INSTALLING RAIL SPLICES 1. Determine the number of rails required per row of modules. 2. Insert a rail splice into one rail. Do not push it past the center bump. 3. Slide the next rail onto the rail splice until the two rail ends meet. 4. Repeat steps 2 and 3 until the desired length is achieved. This is usually easiest to do from the ground. PAGE 08 REVISION DATE:09/9/22 VERSION:v2.7 CLICK . INSTALLATION GUIDE aOo ECOFQStell" `� For Installers. By Installers. . INSTALLATION OF FLASHING & L-FOOT • ClickFit for camp shingle roofs uses EcoFasten GF-1 watertight flashing system. • Other roof types may use different EcoFasten Solar attachments, visit ecofastensolar.com to learn about other applications. 'Note the orientation of the L foot and Clicker.The two Clicker"arms"should be facing downslope' INSTALLATION STEPS: 0 0 ' o 1. Locate rafter lines. 2. Drill 1/4" pilot holes at all attachment points and back fill using roof- compatible sealant. 3. Separate shingles where flashing is to be installed. Insert the flashing so the top portion is under the next row of shingles North. Ensure the flashing is pushed to the third-course of shingle to prevent water infiltration through the vertical joints between shingles. 4. Align GF-1 flashing hole with pilot hole. Insert the lag bolt with pre-installed bonded washer through the L foot and EPDM grommet. Tighten the lag bolt until fully seated. The EPDM Ring visual indicator is the most effective way to ensure a watertight seal. PAGE 09 REVISION DATE:03/3al VERSION:v2.7 CLICK ,;. A INSTALLATION GUIDE o�d EcoFasten. For Installers. By Installers. INSTALLING TILE HOOKS \ 1. Locate rafters on the roof, mark the tiles to be removed. Hint: In some cases rafter tails are visible at the eaves of the roof, making it easy to find the rough location of the rafters. h.s\s,N In other cases,the fascia board may have nail heads visible where it was attached to the rafters. In the worst-case a row of tiles may need to be moved to determine the rafter \1/4\\ locations. 2. Slide the tile at the desired location upward to expose the roof sub surface. If the tile is to be notched, or if using a replacement flashing, remove it entirely.Clean the sub surface with a brush to remove any debris that could affect the sealing. \\*1/444\\\. 3. Locate the rafter center and mark it. 4. Place the tile hook with the hook itself in the valley of the next tile below. Drill one 1/4" pilot hole in the rafter center,taking care to keep the hook in the valley of the tile below. CO Backfill this hole with a roof-compatible sealant. For flat tiles,try to avoid having the hook land directly under a joint between tiles,this will create a larger gap or more notching than necessary. 5. Install one 5/16"x 4" lag screw on the row of holes closest to the tile hook arm. If possible, 11 .1 install the screw in one of the three holes directly next to the arm. If the lag screw must be installed in one of the seven holes furthest from the arm(denoted by the red rectangle below), install three deck screws in the pattern shown by the green circles below. IOC 6. Adjust the height of the tile hook as necessary using the bolt shown in the fourth image. IIIIIIIIIIII 7. Flash the surrounding area and lag screw head with roof-compatible sealant as necessary. Refer to Tile Hook Subflashing Installation guide on the next page. 8. Replace the tile that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding111111% wheel or by using a chisel. f' 000000c/ > twi ti-k.:,*- 14:7:— k sal/ . I 5. e z 1 '\%*ss:les4 ,,0 ,; \ . _ - 1 1 `.' " r'!' PAGE _r -�- 10 REVISION DAM wnrc vEuroN:.s7 I CLICK INSTALLATION GUIDE I EcoFasten. For on1 -V-1 ilit'ls. By Installers. TILE HOOK SUB-FLASHING INSTALLATION TOOLS REQUIRED: Caulking gun, roofing mastic applicator MATERIALS REQUIRED: Roofing mastic, reinforcing fabric, roof sealant , 4111aPP — ,,e7.,;.' x . a Apply a continuous line of the roofing Lower the sub-flashing over the tile hook base.It may manufacturer's approved sealant on the be necessary to move adjacent tiles to easily lower the underside of the ClickFit tile hook sub-flashing sub-flashing onto the roof deck. to form a U-shape around the raised edges0 --"uillMIIIIIIIIIIIIIIN‘ , 4cr---"Iigiiiii14111111/1/111111141‘, 1 4 . / á• ors'. et r EcoFasten recommends following the TRI guidelines Place the sub-flashing over the base of the tile hook so three-course sealing method.Start the three-course the flashing covers the entire base sealing method by applying a layer of roofing mastic over the edges of the tile hook sub-flashing--111111111 k �. AN zo . , r [ f Place strips of reinforcing fabric over mastic to Apply a final layer of mastic to completely cover cover approximately 2"from the edge of the the reinforcing fabric.The flashing is now installed sub flashing in both directions.Place strips on and sealed. the side first,then the top edge. .MNON DAM.iM2 VERSION:.s7 IN CLICK .. INSTALLATION GUIDE ova EcoFasten. 0 For Insil, Ler. By Installers. CLICKFIT INSTALLATION USING \\N SIMPLEBLOCK-U® 4 k:.,.\ k\\\. , PRE-INSTALLATION: The SimpleBlock-U can be installed on many different standing seam profiles. See SimpleBlock-U Installation Manual for compatible and non-compatible standing seam profiles. Be sure that each standing seam is no thicker than 1/2"in width. INSTALLATION: igiZ O Position the SimpleBlock assembly on t panel O seam. Make sure the block is fully seatedhe on the metal seam. 1110 OTorque the 2 preinstalled oval point set screws to 150in-Ibs using the included 3/16" hex drive. 1111.1.1.111 Nor --' ' O Included with the block, slide the hex holt into the channel on top of the SimpleBlock-U assembly. i. r O Place the ClickFit Universal L-Foot over the hex bolt 0 followed by the serrated flange nut and torque to ',, err, 150in-Ibs. - 'e folding Pronto. Snapping Profiles 12"MAX `i`MAX Ile MAX "MAX II - . .40100<ell z/ _, .- .. 1 PAGE 12 REVISION DATE D!/!qt VBWOik v27 CLICK . N\ INSTALLATION GUIDE ;Oa EcoFasten. For Installers. By Installers. INSTALLING THE RAIL 1. Place the rail in the Clickers. 2. Ensure the rails extend a minimum Qr of 2" past the last attachments in I C each row. 1 ;111111t 3. Push the rail into each L-foot; an audible click should be heard O i-r-D when the rail is fully seated. Verify the rail is sitting flush with both ledges. If attachments are Gr tia extremely misaligned it may be necessary to loosen the leveling d'" bolt and adjust the height of the It07 F;iil' f� L-foot. Tighten the clamping ' bolt r to 144 in-lbs. 1 ' 4. Level the rail if necessary by loosening the bolt attaching the Clicker to the L-foot or tile hook. r u ��i '' 1 1 11 PAGE '1-_---1 13 .4 CLICK \kN\ 0 INSTALLATION GUIDE o04 EcoFasten, For Ins allers. By Installers. MODULE INSTALLATION 0 STALL THE END CLAMPS 1 ON EACH RAIL WHATEVER END YOU ARE STARTING WITH 0Snap the end clamp onto the rail. 0Slide the end cap onto the rail. " Turn the leg of the end clamp around the cap. „----;-,--- ,,,,, , 0 -,--- Z rvfa,• �� 7 ,1/ Emil , O PLACE MODULE Place the module on the rail, ensuring t: tb0h1 e module junc box 0 4;O./ up slope 1,4„„r Q0 ALIGN AND TIGHTEN Slide the module to the end clamp and - \ align it with the array corners.Tighten the end clamp to 96 in-lb O 10-- ..., PAGE 14 REVISION DATE:03/3/E2 VERSION:v1.7 k CLICK t INSTALLATION GUIDE oOa ECOFQStet'1. For Installers. By Installers. INSTALLING ADDITIONAL MODULES a CLICK IT ON , \ \\,.:4\\\ \N Click a mid clamp onto each rail. SP \\S, *� 0 SLIDE IT UP '�t — Slide the mid clamps until they are flush with the side of the existing 0 , ,,_, module. 0 PLACE AND TIGHTEN Place and slide the next module firmly =410 pe against the mid clamps.Align the "�'�` bottom edges of the modules.Tighten mid clamps to 144 in-lb. o Az:-__„__,___ l is - _ .,..., _.,________-_,„ ' -- -'-..----7:7& / 0 -----------... PAGE 15 REVISION DATE swan VERSION:YLI CLICK INSTALLATION GUIDE IOa EcoFasten For Instalers. By Installers. INSTALLING END CLAMPS AT THE END OF A ROW p b . 1. Install the last mid clamps in the row. '/ " .w ', ksN,*\\\\\,s4::'i1/4,, 2. Measure the rails from the last mid clamp to the module width plus 1". 3. Cut the rails at this mark.There is some adjustment in the end cap/clamp so it does not need to be a perfect cut. 4. Install end clamps and end caps,tighten to 96 in-lb Z ALTERNATIVE METHOD: 1. Install the last module in the row, tighten the mid clamps. 2. Using a circular saw with a metal blade, or carefully with a reciprocating saw, cut the rail approximately 1" past the edge of the last module. 3. Install end clamps and end caps,tighten to 96 in-lb Replace the tile that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding wheel or by using a chisel. IMMMI dit PAGE 16 REVISION OATh 111p/22 VERSION:v2.7 Yam,\*\ a \ CLICK . \ - ,Y. INSTALLATION GUIDE d EcoFasten. ,. o, �v fcr Inst��llcr . By Installers. = e ", BONDING AND GROUNDING BONDING PATHS Bonding paths are carried throughout the array in a variety of ways. They are carried module- to-module and module-to-rail through mid clamps, carried at rail-to-rail connections through the bonding jumpers, and carried row-to-row using bonding jumpers either module-to-module on the module frame or rail-to-rail on the ends of the rails. MID CLAMP 2 mid clamps bonding pairs of modules GROUNDING LUG 0 1 ground lug per continuous array ti-S. C.:1 ,,,,e-- z 4110 4.. y� Ar • „7„..,,,,- RAIL SPLICE 1 MODULE JUMPER space bonding adjacent pair of rails 1 module jumper bonding module to module and row to row PAGE 17 - - .,. REVISION DATO 03/2/22 VERNON:127 CLICK I \STALLATION G _ IDE < EcoFasten, For Instdilers. By Installers. GROUNDING Its I 4i 1 c f'14 s k,\' ,i,'k%\°\\\\4\\\ \''44\14\ 4\ 3A . , - CO__ rz : # . " z yy.. NECESSARY COMPONENTS One of the following grounding lugs(or any UL 2703 Compliant ground Lug): • BurndyCL50-1TN Ground Lug(UL 2703 - E3514343 / UL 467-E9999) • ILSCO SGB-4 Ground Lug(UL 2703 - E354420 / UL 467- E34440) • ILSCO GBL-4DBT(UL 2703 - E354420/ UL467- E34440) • ILSCO GBL-4DBTH (UL 2703 - E354420/ UL 467- E34440) • ILSCO GBL-4SS (UL 2703 - E354420/ UL 467 - E34440) *Equipment grounding wire should be sized in accordance with the National Electrical Code, NFPA70 PAGE and a minimum of 1/4"clearance is required between bare copper wires and aluminum components. REVISION OAT!:3S/3R3 VNwON:1r3.7 k - CLICK t, e NSTALLATION GUIDE ;�a EcoFasten. For Installers. By Installers. , ,,„ 4 :.\ ,> MLPE MOUNT INTALLATION eJ \. \0...g... • t_, / isa -1,\„,,,k1/4\. Lower the MLPE Mount to the rail Tilt and hook the mount around the top"dog ear"of the rail CD Set the MLPE Mount flush with the top of the rail Slide the microinverter flange between the MLPE Mount and the serrated bolt flange aMINI r--� Z (7) IX ,, rf CD Tighten the bolt to 144 in-lbs Repeat this process for all other microinverter and/or optimizer installations4 PAGE 19 REVISION DAM WW2 VERSION:viz CLICK 0 I \ STALLATIO(� GUIDE ooa EcoFasten For Installers. By Installers. tw WIRE CLIP INSTALLATION 1. • With the ClickFit Rail in place and the Wire Clip in hand, place the wire 2 end on either side of the rail. With the wire end touching the bottom lip f of the rail, roll and click- in the Wire Clip to the opposite end of the rail. 4'.4f 3. You will hear an audible 001404,click when the Wire Clip x. , is set in place. F PAGE 20 REVISION DATE:03/3/22 VERSION:v2.7 CLICK INSTALLATION GUIDE ;Oa Eco For Installers. By Installers. FRAME MLPE MOUNT t UI) P P P INSTALLING THE FRAME MLPE MOUNT ACCESSORY: • Install the Frame MLPE Mount • Slide the Frame MLPE Mount onto the lip of the micro-inverter/power optimizer. • Slide the micro-inverter/power optimizer into the opposite lip of the module frame. • Tighten the bolt to 144 in-lb to clamp the Frame MLPE Mount to the module frame and theCfJ micro-inverter/power optimizer to the Frame MLPE Mount. • Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the clip flange to avoid rotation during tightening. FRAME MLPE MOUNT AND MLPE MOUNT ARE COMPATIBLE WITH: LI • ENPHASE: M250-72, 250-60, M215-60, C250-72, S230, S280, IQ 6, IQ 6+, IQ7, IQ 7A, IQ 7+, IQ7 10 PD, IQ 7X, Q Aggregator; IQ8-60, IQ8PLUS-72, IQ8A-72, IQ8H-208-72, IQ8H-240-72, IQ8M-72, may be followed by-2-US • SOLAREDGE: M1600, P300, P320, P340, P370, P400, P401, P405, P485, P505, P600, P700, P730, P800p, P800s, P801, P850, P860, P950, P960, P1100, P1101, S440, S500 • SEE PAGE 26 FOR COMPATIBLE MODULE LIST PAGE 21 REVISION DATE:03/3/22 VERSION:v2.7 li CLICK INSTALLATION GUIDE o�a EcoFosten For Installers. By Installers. MODULE MAINTENANCE AND SERVICING During servicing or maintenance, module removal may disrupt the bonding path and could introduce the risk of electric shock. If module removal is required for servicing,then a Module Jumper shall be installed to the adjacent modules to maintain the bond path. Modules should only be removed by qualified persons in compliance with the instructions in this manual. — Bond Path Grounding Lug Equipment Grounding Conductor(EGC) generally to earth ground . Brackets/Mid-Clamps Module Jumper PAGE 22 REVISION DATE OOA#1 VERSION:Y2.7 "k CLICK b oa EcoFasten INSTALLATION GUIDE o For istallcrs. By Installers. JUNCTION BOX INSTALLATION - \\*\\ P I JUNCTION BOX PREP Prior to installation, use step drill bit to place pass through holes for conduits or water-tight connectors. Drill bit starter locations are provided on the sides and front of enclosure. Do not install conduit facing up roof. UI) LI LI _ RAIL INSTALLATION et` Use rail-specific MLPE mounting hardware to attach Rail Hangers to rail. Ensure junction box is pushed as close to the rail as possible.Torque to 80-in Ibs(1/2"or 7/16" socket), do not overtighten. *I f installing in areas with ground snow loads greater than 40 psf,install Junction Box under module directly next to module frame edge. PAGE 23 SIVKION DATE NIA/72 :n, CLICK INSTALLATION GUIDE a EcoFasten v1\6 s\4:1\-\::44'.\4\ For Installers. By Installers. JUNCTION BOX INSTALLATION 6\*\\\ DECK SCREWS WITH SEALING WASHERS(2)() DECK MOUNTED INSTALLATION Align sealing oval of box to align with mating feature on flashing.An EPDM foam gasket is pre-installed to the underside of the junction box to seal the flashing to the box without the need for additional sealant. Secure with supplied #12 x 1- "deck screws (2x) until the junction box is pulled tight to the flashing. Do not over-tighten screws to avoid stripping screws in OSB. *If installing pass through fittings,ensure that the Junction Box and roof deck are both properly prepared.Complete installation process before attaching the Junction box to the deck. 11111111 FINALIZING INSTALLATION Install wiring, conduit and fittings per NEC requirements and following local AHJ guidance. Using Philips Head Driver tighten the bolt. For additional details refer to the full Junction Box Installation Manual. PAGE 24 REVISION RATE:03/3/22 VERSION:v3.7 CLICK a INSTALLATION GUIDE 04 EcoFasten, For Installers. By Installers. SKIRT INSTALLATION (OPTIONAL) , The skirt is designed to give the rows of the array facing the eave of the roof a uniform appearance.The installation consists of three basic components listed below. 1.11..111. a IN SKIRT & END CAP r SKIRT CLAMP Ull) 1. Once the first row of modules is installed(or after the array is complete), locate the correct _ MU_ length and number of skirts for the array. 2. Locate the correct amount of skirt clamps for the array. 80"skirts are preferred when applicable.The general rule when using 80"skirts is the number of modules plus one for the end of the array.When using 65"skirts,the rule changes to 2 skirt clamps per module.The IX general rule is number of modules plus one for the end of the array. If you have ten modules you will need eleven skirt clamps. In the case of heavy snow loads or other circumstances call EcoFasten Solar for additional instructions. CD 3. Working with a helper, align the end of the skirt with one edge of the array, drop the first skirt clamp onto the module and skirt, ensure all flat faces are parallel and fully engaged with each other. Skirt clamps must be installed within 10 inches from the end of the Skirt. Ensure the UI) clamp is engaging either the top of the skirt or the step depending on the module size.Tighten bolt to 12 ft-lb. Cr) 4. There should be enough play in the assembly to drop the next skirt clamp onto the next module at roughly the same location relative to the clamp on the last module. Ensure all IOU faces are parallel and fully engaged with each other. Slide next skirt over the skirt end cap or coupling of the first skirt.Tighten bolt to 12 ft-lb. 5. Repeat steps 3 and 4 until the end of the array is reached. Install a skirt clamp within 10 LI inches from the end of the array. Cut the skirt flush with the end of the array as necessary.An additional skirt clamp may be necessary to hold a short piece of skirt at the end of the array. 0 6. Once the last skirt is cut and clamped in place, install an end cap in the end of the last skirt.To ensure the end cap stays in place through various weather conditions, it is acceptable to install - a small amount of roof sealant onto the edge of the end cap that will contact the inside face -14111 of the skirt. Replace the tile that was moved and/or removed,or install the tile replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding wheel or by using a chisel. PAGE 25 REVISION OAM%Wf/a vw10IN vZ.1 bs' \ ,#a CLICK poa INSTALLATI N G ._ IE oA4 EcoFasten \\\,,,4,\N For Instaiiers. By Installers. \ fr Install first skirt clamp within 10 inches from �> , the end of the array with 80"skirts,the second '`$.. o ' clamp location will be similar to the first clamp �� but installed on the second module. Continue to '' the end of the array. f °. ,4, !gip ✓ JI Con ,f um! Install last skirt clamp within 10 inches from the end of the array prior to cutting. 11111111111111111111 Ce 0 Install end cap on the last module.Adding a ti small amount of sealant is optional. Ull) THINGS TO CONSIDER PRIOR TO INSTALLING THE SKIRT ARE: • Potential snow drifting in the area the skirt is to be installed. If the snow load is greater than 20psf in your region two skirt clamps are required per module and skirt coupler must be used. Contact EcoFasten for information on the skirt coupler. , • There are three options for skirts:A, B and C.The A& B skirts can be identified by looking ' at the inner channel, if it's ribbed then it is a B skirt and will use 32mm (inner channel) and 38mm utilizing the top of the skirt. A skirts will have a smooth inner channel and use PAGE 35mm (inner channel)and 40mm utilizing the top of the skirt. C skirts will only use 30mm skirts and do NOT have an inner channel. REVISION DATE:03/3/22 VERSION:v2.7 CLICK; e INSTALLATION GUIDE o 1 EcoFasten. For Installes. By Installers. UL 2703 CERTIFIED MODULES This racking system may be used to ground and/or mount a PV module complying with UL 1703 or UL 61730 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. " " MANUFACTURER LIST OF UL 2703 APPROVED MODULES Adani modules with 35 and 40mm frames ASX-Y-ZZ-xxx Adani Where"X"can be B, M or P,"Y"can be 6 or 7,and"ZZ"can be blank, PERC, B-PERC,or AB-PERC Aionrise modules with 35 and 40mm frames Aionrise AIONyyG1-xxx Where"yy"can be 60 or 72 Amerisolar modules with 35,40 and 50 mm frames 111/11111111/ AS-bYxxxZ Amerisolar Where"b"can be 5 or 6;"Y"can be M, P, M27, P27, M30, or P30; and""Z"" can be blank,W or WB Aptos modules with 35 and 40 mm frames Aptos Solar DNA-yy-zzaa-xxx Where"yy"can be 120 or 144;"zz"can be MF or BF;and"aa"can be 23 or 26 Astronergy modules with 30,35,40,and 45 mm frames aaSMbbyyC/zz-xxx Astronergy Solar Where"aa"can be CH or A;"bb"can be 60,66,or 72;"yy"can be blank, 10 or 12;"C"can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and "zz"can be blank, HV, F-B, or F-BH ASUN modules with 35 and 40 mm frames ASUN-xxx-YYZZ-aa ASUN Where"YY"can be 60 or 72;"ZZ"can be M,or MHS;and"aa"can be blank or BB Auxin modules with 40 mm frames AXN6y6zAxxxB Auxin Where'y'can be M or P;"z"can be 08,09, 10, 11, or 12; and"A"can be F, M or T; and"B"can be blank,A, B or C PAGE 27 REVISION DATE:D3/3/22 VERSION:v2.7 CLICK e INSTALLATION GUIDE o0e EcoFasten. For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES Axitec Modules with 30, 35 and 40 mm frames AC-xxxY/aaZZb Axitec Where"Y"can be M, P or MH;"aa"can be blank, 125-or 156-;"ZZ"can be 54, 60, 72, 108, 120, or 144; "b"can be S,X,V,VB,XV, or MX Boviet modules with 35 and 40mm frames BVM66aaYY-xxxBcc Boviet Where"aa"can be 9, 10 or 12;"YY"is M, or P; and"B"can be blank, L or S; and"cc"can be blank, H, H-BF, H-HC, HC-BF or H-HC-BF BYD modules with 35 mm frames BYDxxxAY-ZZ BYD Where"A"can be M6, P6, MH or PH; "Y"can be C or K; and"ZZ"can be 30 or 36 Canadian Solar modules with 30,35 and 40 mm frames CSbY-xxxZ Canadian Solar Where"b"can be 1,3 or 6;"Y"can be H, K, L, N, P, U,V,W,X or Y;and "Z" can be M, P, MS, PX, M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed modules with 35 and 40mm frames CTxxxYZZ-AA CertainTeed Where"Y"can be M, P, or HC; "ZZ"can be 00,01, 10, or 11; and "AA"can be 01, 02, 03, 04 or 06 Csun modules with 35 and 40 mm frames CSUN YYxxx-zzAbb Where"YY"is CSUN or SST;"zz"is blank, 60,or 72; and"A"is blank, P or M or MM;"bb"is blank, BB, SBB, BW, or ROOF Dehui modules with 35 and 40mm frames Dehui DH-MYYYZ-xxx Where"YYY"can be 760,772,860,872; and"Z"can be B or W Ecosolargy modules with 35,40, and 50 mm frames Ecosolargy ECOxxxYzzA-bbD Where"Y"can be A, H,S, or T;"zz"can be 125 or 156; "A"can be M or P; "bb" can be 60 or 72; and"D"can be blank or B ET Solar modules with 35,40, and 50 mm frames ET-YZZZxxxAA ET Solar Where"Y"can be P, L, or M;"ZZZ"can be 660, 660BH,672,672BH,754BH or 766BH; and"AA"can be TB,TW,WB,WW, BB,WBG,WWG,WBAC,WBCO, WWCO,WWBCO or BBAC PAGE 28 REVISION DATE:03/3/22 VERNON:v27 CLICK INSTALLATION GUIDE oOa EcoFasten� For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES Flex modules with 35,40,and 50 mm frames Flex FXS-xxxYY-ZZ; Where"YY"can be BB or BC;and"ZZ"can be MAA1 B, MAA1 W, MAB1 W, SAA1 B,SAA1 W, SAC1 B, SAC1W,SAD1 W,SBA1 B, SBA1 W,SBC1 B, or SBC1W GCL modules with 35 mm and 40 mm frames GCL-ab/YY xxx GCL Where"a"can be M or P;"b"can be 3 or 6; and'YY"can be 60,72,72H, or 72DH Gigawatt modules with 40 mm frames GigaWatt Solar GWxxxYY Where"YY"can be either PB or MB Hansol modules with 35 and 40 frames HSxxxYY-zz Hansol Where"YY"can be PB, PD, PE,TB,TD, UB, UD, or UE; and"zz"can be AH2, AN1,AN3,AN4, HH2, HV1, or JH2 Hanwha Solar modules with 40,45,and 50 mm frames HSLaaP6-YY-1-xxxZ Hanwha Solar Where"aa"can be either 60 or 72;"Yr can be PA or PB;and"Z" can be blank or Ba,a td Hanwha Q CELLS Modules with 32, 35,40,and 42mm frames jl I aaYY-ZZ-xxx where"aa"can be Q. or B.;"YY"can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK DUO;and"ZZ"can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/ SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK Hanwha Q CELLS G4.1/SC, EC-G4.4, G5, G5/SC, G5/TS, BLK-G5, BLK-G5/SC, BLK-G5/TS, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6/SC, G6/TS, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/HL, BLK-G6+/SC, \t.\ BLK-G61TS, G6+/TS, BLK-G6+/TS, BLK-G7,G7.2, G8, BLK-G8,G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/BFF, ML-G9, BLK ML-G9, ML-G9+, BLK ML-G9+, BLK-G10+, BLK-G10+/AC, ML-G10, BLK ML-G10, ML-G10+, BLK ML-G10+, ML-G10.a, BLK ML-G10.a, ML-G10.a+, BLK ML-G10.a+,XL-G9,XL-G9.2,XL-G9.3,XL-G10.2,XL-G10.3, XL-G10.c or XL- G10.d PAGE 29 REVISION DATE:09/3/22 VERSION:v2.7 CLICK 0 INSTALLATION GUIDE o�a EcoFasten, For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES Heliene modules with 40 mm frames YYZZxxxA Heliene Where"YY"can be 36, 60,72, 96, 120 or 144;"ZZ"can be HC, M, P, or MBLK; and"A"can be blank, HomePV,or Bifacial HT-SAAE modules with 35 and 40 mm frames HT-SAAE HTyy-aaaZ-xxx Where"yy"can be 60, 66 or 72;"aaa"can be 18, 156 or 166;"Z"can be M, P, M-C, P-C, M(S), M(VS), M(V), P(V), M(V)-C, P(V)-C, or X Hyundai modules with 33, 35,40 and 50 mm frames HiY-SxxxZZ Hyundai Where"Y"can be A, D or S;"S"can be M or S;and"ZZ"can be HG, HI, KI, MI, MF, MG, PI, RI, RG, RG(BF), RG(BK),SG,TI or TG Itek Modules with 40 and 50 mm frames Itek IT-xxx-YY Where"YY"can be blank, HE, or SE, or SE72 JA Solar modules with 30, 35,40 and 45 mm frames JAyyzz-bbww-xxx/aa Where"yy"can be M, P, M6 or P6;"zz"can be blank,(K), (L), (R),(V),(BK),(FA), JA Solar (TG),(FA)(R),(L)(BK), (L)(TG),(R)(BK), (R)(TG),(V)(BK), (BK)(TG), or(L)(BK)(TG); "bb"can be 48, 54, 60, 66,72 or 78;"ww"can be D09, S01, SO2, S03, S06, SO9, S10, S12, S17,S20, S30 or S31; and"aa"can be BP, MR, SI,SC, PR,3BB, 4BB,4BB/RE, 5BB Jinko modules with 35 and 40 mm frames J KMYxxxZZ-aa Where"Y"can either be blank or S;"ZZ"can be M, P, or PP; and"aa"can be Jinko blank, 60, 60B, 60H,60L, 60BL,6OHL,60HB, 60HBL, 6HBL-EP,60 J4,60B-J4, 60B-EP, 60(Plus), 60-V, 60-MX, 6RL3, 6RL3-B, 6TL3-B, 7RL3-V, 7RL3-TV, 72, 72B, 72-J4,72B J4,72(Plus),72-V, 72H-V, 72L-V,72HL-V, 72-MX,72H-BDVP, 72HL-TV, or 72HL-V-MX3 Kyocera Modules with 46mm frames KYxxxZZ-AA \\\\\\ Kyocera Where"Y"can be D or U;"ZZ"can be blank, GX, or SX; and"AA"can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2,3AC, 3BC, 3FC,4AC,4BC,4FC, 4UC, 5AC, SBC, SFC, SUC, 6BC, 6FC,8BC, 6MCA,or 6MPA LG modules with 35,40,and 46 mm frames LGxxxYaZ-bb LG Where'Y'can be A, E,M,N,Q,S;"a"can be A, 1,2 or 3;"Z"can be C, K,T,or W; PAGE and"bb"can be A3,A5,A6, B3, B6, E6, E6.AW5,G3,G4,J5, K4, L5, N5,V5,V6 30 REVISION DATE:03/3/22 VERSION:v2.7 CLICK INSTALLATION GUIDE ;Oa EcoFQ� a For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES Longi modules with 30,35 and 40 mm frames LRa-YYZZ-xxxM Longi Where"a"can be 4 or 6; "YY"can be blank,60, 66 or 72; and"ZZ"can be blank, BK, BP, HV, PB, PE, PH, HBD, HIB, HIH, HPB, HPH, or HIBD Mission Solar modules with 33,35 and 40 mm frames YYYbb-xxxZZaa Mission Solar Where"YYY"can be MSE or TXS;"bb"can be blank, 6 or 60A;"ZZ"can be blank, MM, SE, SO, SQ, SR, SX,TS, 120 or 144; and"aa"can be blank, BB, BW, 1J,4J, 4S, 5K, 5R, 5T, 60, Si, 6S, 6W, 6Z,8K, 8T, or 9S Mitsubishi modules with 46 mm frames Mitsubishi PV-MYYxxxZZ Where"YY"can be LE or JE; and"ZZ"can be either HD, HD2, or FB Motech IM and XS series modules with 40,45,and 50 mm frames Next Energy Alliance modules with 35 and 40mm frames Next Energy yyNEA-xxxZZ Alliance where"yy"can be blank or US;"ZZ"can be M, MB or M-60 Neo Solar Power modules with 35 mm frames Neo Solar Power D6YxxxZZaa Where"Y"can be M or P;"ZZ"can be B3A, B4A, E3A, E4A, H3A, H4A;and"aa" can be blank,(TF), ME or ME(TF) Panasonic modules with 35 and 40 mm frames Panasonic(HIT) VBHNxxxYYzzA Where"YY"can be either KA, RA,SA or ZA;"zz"can be either 01, 02, 03, 04, 06,06B, 11, 11B, 15, 15B, 16, 16B, 17, or18; and"A"can be blankE,GorN Panasonic modules with 30 mm frames Panasonic EVPVxxxA (EverVolt) Where"A"can be blank or H, K or PK Peimar modules with 40 mm frames SbxxxYzz Peimar Where"b"can be G, M or P;"Y"can be M or P;and"zz"can be blank, (BF), or (FB) Philadelphia modules with 35 and 40 mm frames PS-YzzAA-xxx Philadelphia Solar Where"Y"can be M or P;"zz"can be 60, 72 or 144; and"AA"can be blank, (BF),(HC)or(HCBF) PAGE 31 REVISION DATE:09/3/22 VERSION:v2.7 CLICK INSTALLATION GUIDE oDa EcoFasten. For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES Phono Solar modules with 35,40,and 45 mm frames PSxxxY-ZZ/A Phono Solar Where ur can be M, M1, MH, MIN, M4, M4H, or P; "ZZ"can be 20 or 24; and"A"can be F,T, U, UH, or TH Recom modules with 35 and 40 mm frames Recom RCM-xxx-6yy Where"yy"can be MA, MB, ME or MF REC modules with 30, 38 and 45 mm frames REC Solar RECxxxYYZZ Where"YY"can be AA, M, NP, NP2, PE, PE72,TP, TP2,TP2M, TP2SM,TP2S, TP3M or TP4; and "ZZ"can be blank, Black, BLK, BLK2, SLV, 72 or Pure ReneSola modules with 35,40 and 50 mm frames AAxxxY-ZZ Renesola Where"AA"can be SPM(SLP)or JC;"Y"can be blank, F, M or S; and"ZZ" can be blank,Ab,Ab-b,Abh,Abh-b,Abv,Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Renogy Modules with 40 and 50 mm frames Renogy RNG-xxxY Where"xxx"is the module power rating; and"Y"can be D or P Risen Modules with 35 and 40 mm frames Risen RSMyy-6-xxxZZ Where"yy"can be 60,72, 120, 132 or 144; and"ZZ"can be M or P S-Energy modules with 35 and 40mm frames SABB-CCYYY-xxxZ S-Energy Where "A"can be C, L or N;"BB"can be blank, 20,40 or 45;"CC"can be blank, 60 or 72;"YYY"can be blank, MAE, MAI, MBE, MBI, MCE or MCI;and "Z"can be V, M-10, P-10 or P-15 SEG Solar modules with 35 and 40 mm frames SEG-aYY-xxx-ZZ SEG Solar Where"a"can be blank, 6 or B;"YY"can be blank, MA, MB, PA, or PB; and "ZZ"can be blank, BB, BG, BW, HV,WB,WW, BMB, BMA-HV, BMA-TB, BMB- HV, BMB-TB, BMD-HV Seraphim modules with 35,40 and 50 mm frames SRP-xxx-YYY-ZZ Seraphim USA Where"xxx"is the module power rating; and"YYY"can be 6MA, 6MB, 6PA, 6PB, BMD, 6QA-XX-XX, and 6QB-XX-XX; ZZ is blank, BB or HV PAGE 32 REVISION DATE:03E3E22 VERSION:v2.7 CLICK INSTALLATION GUIDE Ca 4 EcoFasten For Installers. By Installers. + `+ MANUFACTURER LIST OF UL 2703 APPROVED MODULES Sharp modules with 35 and 40 mm frames Sharp NUYYxxx Where"YY"can be SA or SC Silfab Modules with 35 and 38 mm frames Silfab SYY-Z-xxxAb Where"YY"can be IL,SA, LA,SG or LG;"Z"can be blank, M, P, or X;"A"can be blank, B, H, M, N; and"b"can be A, C, G, K, L, N,T, U or X Solaria modules with 35 and 40 mm frames PowerXT-xxxY-ZZ Solaria Where"Y"can be R or C; and"ZZ"can be AC, BD, BX, BY, PD, PL, PM, PM-AC, PX, PZ,WX or WZ Solarcity modules with 40 mm frames Solarcity SCxxxYY (Testa) Where"YY"can be blank, B1 or B2 SolarTech modules with 40 and 42 mm frames SolarTech ' -xxxYY Where"MA"can be PERCB-B, PERCB-W, HJTB-B, HJTB-W or STU;"YY"can be blank, PERC or HJT SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 31, 33 or 46 mm SolarWorld AG frames SW-xxx SolarWorld Sunmodule Plus, Protect, Bisun,XL, Bisun XL, may be followed SolarWorld by mono, poly,duo, black, bk, or clear; modules with 33 mm frames Americas SWA-xxx Sonali Sonali Modules with 40 mm frames SSxxx Stion Thin film modules with 35 mm frames Stion STO-xxx or STO-xxxA SunEdison Modules with 35,40&50 mm frames SE-YxxxZABCDE SunEdison Where"Y"can be B, F, H, P, R, or Z;'7"can be 0 or 4;"A"can be B, C, D, E, H, I,J, K, L, M, or N; "B"can be B or W;"C"can be A or C;"D"can be 3, 7,8,or 9; and "E"can be 0, 1 or 2 Suniva modules with 35, 38,40,46, and 50 mm frames OPTxxx-AA-B-YYY-Z Suniva MVXxxx-AA-B-YYY-Z PAGE Where"AA"is either 60 or 72;"B"is either 4 or 5;"YYY"is either 33 100,101,700,1 B0, or 1 B1; and"Z"is blank or B REVISION DATE:O3/3/22 VERSION:v2.7 CLICK A INSTALLATION GUIDE t 1 EcoFasten,- For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES Sunpower standard(G3 or G4)or InvisiMount(G5)35,40 and 46 mm frames SPR-Zb-xxx-YY Sunpower Where"Z"is either A, E, P, M or X;"b"can be blank, 17, 18, 19, 20,21, or 22; and"YY"can be blank, BLK,COM, C-AC, D-AC, E-AC, BLK-E-AC, G-AC, BLK-C- AC, or BLK-D-AC Sunspark modules with 40 mm frames SYY-xxxZ-A ! ' `S4 Sunspark Where"YY"can be MX or ST; and"Z"can be M, MB, M3, M3B, P or W; and "A"can be 60 or 72 d63�r°-d5'nx4 .wH7vk .s.v' .�arz" Suntech Modules with 35,40 and 50mm frames STPxxxy-zz/aa Suntech Where"y"is blank or S; and"z"can be 20, 24,A60 or A72U;and"aa"can be Vd,Vem,Vfw,Vfh,Wdb,Wde,Wd,or Wfhb CIn Talesun modules with 35 and 40mm frames TP6yZZaaxxx-b Talesun Where"y"can be blank, F, H, or L;"ZZ"can be 60 or 72;"aa"can be M, M(H), or P; and"b"can be blank, B,T,or(H) j J Tesla modules with 40 mm frames Tesla TxxxY Where"""can be H or S Trina Modules with 30, 35,40 and 46mm frames TSM-xxxYYZZ Where"YY"can be DD05, DD06, DD14, DE09, DE14, DE06X, DE15, DE15V, Trina DEG15, PADS, PC05, PD05, PD06, PA14, PC14, PD14, PE14, or PE15;and"ZZ" can be blank, (II), .05, .05(11), .08, .10, .18, .08D, .18D,0.82, .002, .00S, 05S, 085,A,A.05,A.08, A.10,A.18,A(II),A.05(II),A.08(II),A.082(II),A.10(II),A.18(II), H, H(II), H.05(11), H.08(11), HC.20(II), HC.20(II), M, M(II), M.05(11), MC.20(II) URE modules with 35 mm frames URE DyZxxxaa Where"D"can beDorF,"y"can beA,6or7;"Z"can beKorM; and"aa"can be H3A, H4A, HBA, E7G-BB, E8G or E8G-BB Vikram solar modules with 40 mm frames VSyy.ZZ.AAA.bb Vikram Where"yy"can be M, P, MBB, MH, MS, MHBB, or PBB; "ZZ"can be 60 or 72; "AAA"is the module power rating; and"bb"can be 03, 04 or 05 PAGE 34 REVISION DATE 09/3/22 VERSION:v2.7 CLICK INSTALLATION GUIDE o�a EcoFastena For Installers. By Installers. MANUFACTURER LIST OF UL 2703 APPROVED MODULES VSUN modules with 30,35 and 40 mm frames VSUN VSUNxxx-YYz-aa Where"YY"can be 60, 72, 108, 120, or 144;"z"can be M, P, MH, PH, or BMH; and"aa"can be blank, BB or BW Waaree modules with 40mm frames Waaree WSyy-xxx where"yy"can be blank or M Winaico modules with 35 and 40 mm frames Wsy-xxxZa Winaico Where"y"can be either P or T; "Z"can be either M, P, or MX;and "a"can be blank or 6 Yingli modules with 35 and 40 mm frames Yingli YLxxxZ-yy Where"Z"can be D or P; "yy"can be 29b,30b,34d, 35b, 36b or 40d ZN Shine modules with 35mm frames ZN Shine ZXMY-AM-xxx/M Where"1Y"can be 6 or 7,"AAA"can be 72, NH120, NH144 or NHDB144 PAGE 35 REVISION DATE:03/3/21 VERSION:v2.7 CLICK e INSTALLATIC[\ GUIDE :0e EcoFasten. For Installers. By Installers. - CLAMPPARTNUMBERS END CLAMPS Frame Thickness Article Number 30 mm 2099016 \\\ 32 mm 2099017 35 mm 2099018 Cr) 38 mm 2099019 40 mm 2099020 MEI 45 mm 2099021 1114 MID CLAMPS F— Frame Thickness Article Number 30-40 mm 2099022 1111111111111 40-50 mm 2099023 INSTALLER RESPONSIBILITIES Periodic re-inspection of components shall be performed to verify that there is no corrosion detrimental to system strength and electrical conductivity, no loose bolts,and/or other variables that could compromise array safety.Any corroded or damaged components shall be immediately replaced. PAGE 36 c. ti �� R* o0o EcoFastenp For Installers. By Installers. 4 . A: n e s - •�'A_s� Q^ ti.• . H L,. ` 1�t vf` .`tee' • ".'S` 4Y"'•. w ✓ `HK k SL_ ,iF si X3 '!!. .,..ems. . "� .h :;' 1.�Y'.••1—y,�7L F • 3k �' yrt, Nimedip JJ_ r� y� q le, eido ordo rill 7 .... //////%//////////////////////////// COMPLETE MOUNT & FLASHING ASSEMBLY oryiii F. �1 ' //v ff%!ii' ////��JiffJ%/�liisr�r%%/%` i�li.fl'f'%f/� I \ STALLAT ,..__, N J 1 1 E REVISION: 04/05/22 VERSION: V2.4 z,////ell:.//��7,,,„• 1 //e/ 1/i//.�//F1311//�j ECOFASTENSOLAR.COM REVISION 04/05122 VERSION.V2.0 G F-i . 00o EcoFasterr INSTALLATION GUIDE V For Installers. By Installers. CLICKING THE PAGE NAME WILL TAKE YOU TO THAT PAGE TABLE OF CONTENTS PAGE 01 FEATURES & BENEFITS PAGE 02 COMPONENTS PAGE 03 INSTALLATION PAGE 04 LINE DRAWINGS PAGE 06 SPECIFICATIONS PAGE 12 PAGE 01 REVISION:0005/22 VERSION:V2.4 0 - GFimi Dop t0 EcoFasten - INSTALLATION GUIDE For Installers. By Installers. r A spg,„ y; Y �'pi APp b 1 *f OJ O' FLA39W1 \ ♦ /+2► tP(a ATE OF . �/TY NuaRSO/< Cri Cn GF-1 GE-1 is our most versatile solution for composition shingle roofs. Install the flashing using a single fastener for a quick & easy installation. When using the GF-1 flashing grommet and an EcoFasten compression bracket, a watertight seal is created, maintaining the integrity of the roof. FEATURES • Mill or black finish 1114• Patented Watertight Technology • Installs without removing shingles • Single lag bolt attachment • Compatible with a variety of compression brackets • Florida Product Approved for any combinationof 8"x12"GF-1 flashing with the ClickFit L-foot&Lag Screw PAGE 02 REVISION:04/05/32 VERSION:VS G F INSTALLATION GUIDE o0a EcOFasten For Installers. By Installers. SYSTEM COMPONENTS 0 cn 0 0 I- 0 UNI - 1. L-FOOT SCL-101 BLK 3" 4. GF-1 FLASHING GLV MLL 8X12" - (OTHER OPTIONS AVAILABLE) GALVALUME FLASHING WITH PRE- - INSTALLED EPDM RUBBER GASKET 2. 5/16" LAG BOLT (AVAILABLE IN 3"AND 4") (AVAILABLE IN 8X10&8X12,WITH MILL&BLACK FINISH OPTIONS) 3. 5/16" EPDM BONDED WASHER PAGE 03 REVISION:06/05/22 VERSION:V2.4 GF.1 INSTALLATION GUIDE EcoFasten For Installers. By Installers. INSTALLING GF-1 Snap horizontal lines across the roof to mark the mount rows, then locate the rafter and mark the installation position of each GF-1 flashing. Z 11111111111111111 Flinn Drill a 7/32"pilot hole into the rafter or structural member for the lag screw. Backfill with sealant • compatible with the roof type. 1111111111111 fn. 14% FMMI. 191411ilir z Slide flashing up under the next row ' of shingles directly above the pilot hole,taking care to align the hole in the flashing with the pilot hole. PAGE 04 REVISION:04/05/22 VERSION:V2.4 GF-1 1111111111111Cin\14:4111.111111111.1.111:1111111111111i:IN INSTALLATION GUIDE d0a EcoFasten4 For Installers. By Installers. INSTALLING GF-1 Thread the EPDM bonded washer \kk onto the lag bolt followed by one of EcoFasten's compression brackets and then insert the lag bolt into the gasketed hole in the flashing. IMP'` Drive the lag bolt down into the 00. _„„ rafter using an impact driver. Torque range is between 100-400 torque inch-pounds depending • `► A. on the type of wood and time of ./ ' ' year.The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. Do not over torque. FIRM Z PAGE 05 REVISION:04/05/22 VERSION:V2.9 GF _Ii y INSTALLATION GUIDE o�a EcoFasten For Installers. By Installers. A CUT SHEET: GF-1 FLASHING GLV MLL/BLK S I REM NO. PART NUMBER DESCRIPTION CITY REV.II( RR,_ I 75004102 GF I-GAL-MLL-812 1 A A aEvse ie_o 5/I6 STAINLESS STEEL AND EPDM 2 150002 BONDED SEALING WASHER I A D D ,,,,,..,„ CD ( 8.00 O [2032] C C c) \-:, _ , 12.00 — 304.8] B B ICC [0]J Cilt OS A THIRD ANGLE PROJECTION� °W - � iI D)[ ( Cial ,A TOoG °9-"CE J 1 INTERPRET DIM AND TaERANCE INNOVATIVE ENIUITIM MI-S DO NOI SCALE DRAWING RER cryEs .,Sim;pWR NovIRrAKr AND eornoErtllAl MANSIONS NSIONS TOLERANCES MEIN:_GF-1 FLASHING GLV MLL 8X12 1.PACKAGE PER"3012011- wcrvEt ynlXL+1-'5 DIE `NC PCK" xx:...01 x:. n 3012011 WI IGF-I FLASHING GLV',ALL 8XI 2'50-PACK INSTI rxx.°CAGE :•/-:!5 A I� N' I A 6 I 5 I 4 r w ••�•ttm ••3 m ••�•� I 35c I I Z Mai PAGE 06 REVISION:6I/05/22 VERSION:V2.4 GF.1 00o EcoFasten INSTALLATION GUIDE For Installers. By Installers. CUT SHEET: L-FOOT L-102 BLK 3" by 4 I 3 _.._.___ _L- [ 1 I ITEM NO. PART NUMBER DESCRIPTION OTT. REV. : I elArcro"' 1 450050-01 L-1023 ANOD BLK 1 01 xeRe ze io acerroamnriwo.mi o.rorxi "erop�n ���9+b 2 150009-08 SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 01 ‘'o 3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-16 I 02 t D D O CD C ® ill C Z IMMO © 00 (V1) • - .- dk. IP _ J 114CB B CIZ A THIRD ANGLE PROJECTION n DUI.w, oo/mvemi � I Dl�� A CI ar. ID arxz D ,o1 rmrsm o4VNU NIERRR7 Dun AND irIERAICECD INNOVATIVE MOUNTING TOMS DO NOT SCALE DRAWIn CV40EUIiISIOLESA5W PRONINARY AND CONNDINM4 DIME45pN5101ERANCES PRF N: L-FOOT L'I O2 BLK 3 I.PACKAGE PER"3011015-PCK" "°Nes "n tmereR;l IL-FOOT L-102 ELK 3"50-PACK INSTI xxx�x 3'D * �r--7ss I Dwa"o 3011015 I•A IIIMLI "srmnRnnv'u = DOLES.-D IDIDE11 know I iwi 6 5 4 1 3.ax Pc. ^I i 1"� Z 111111111111 PAGE 07 REVISION:04/05/22 VERSION:V2.4 G F-1 roxiaj- ooa EcoFasten INSTALLATION GUIDE For Installers. By Installers. CUT SHEET: L-FOOT L-102 MLL 6" ITEM NO. FART NUMBER DESCRIPTION OP/. REV. Nsoxs ,E \\ 1 450082-02 L-102-6 1 01 A en,sr TOss PC ORMITIE,^O e RADII, 2 150009-08 SS HEX HD CAP SCREW,FULL THD,3/B-16 UNC X 125 LONG 1 01 3 150011-03 SS SERRATED FLANGE LOCK NUT.3/8-16 1 02 D D USWAMI © ( 6.00 [152,4] B , B 1111111 THIRD ANGLE PROJECTION rsc °2"wl ��.D (�' 0//(15/21121 IMERPAfl CNA AND'TOLERANCE INNOVATIVE YOYNEMRfIRRYi DO NOB SCALE DRAWING°ERA5NE I451^^I- R r�AEI PROPRIETARY AND LOXHDEXIIAL DMENSICNS TOLERANCES MEIN: L-FOOT L-IO2 y 1LL 6" NC... IARLME'TEA$ I.PACKAGE PER 9011016-PCK' XX ./1 nw v-�s "°U 301 1016 T LIU (GPOOT L-IO2 MLL 6'50-PACK INSTI ux:•ANCL xx RE:•/. A m EA E,c,�nmum n.. +. r.arcc.c ANGLI3.•Fl° " Iwc+� iOFI 6 I 5 I 4 3 2"' � I I:x« _.._ 11111111111111 PAGE 08 REVISION:04/05/22 VERSION:V2.4 CF-i ood EcoFasten INSTALLATION GUIDE V For Installers. By Installers. } CUT SHEET: L-FOOT SCL-101 MLL/BLK 3" Rt ITEM NO PART NUMBER DESCRIPTION QTY. REV. oEicxwwe.oxs ,, 4\.4%\\\%1‘.\*.\\ 1 450049-02 L FOOT W/STANDARD DIMPLE AND OPEN SLOT,3 IN TALL MLL I 01 xex RNNssErossoscww.vr lsco a.. „rFr 2 150009-08 SS H2O HD CAP SCREW.FULL THD,3/8.16 UNC XI.25 LONG I 01 \ 3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-1E 1 02 D D Ulli O CD C 3.0 C ( [762], 1 Z B / B 0 ( .88 [47.6]) I THIRD ANGLE PROJECTION ='„rn ago»xm 1, ��� A .w.rRET'oD TOLERANCE 1 < A aw %I INTERPRET DIM AND TOLERANCE INNOY�TIVF YOWIIRIE IVIEEM{ DO NOT SCALE DRAWING PE°ASMLVl''I"2'7' L-FOOT SCL-101 MLL 3" I.PACKAGE PER"3011017-PCK• PROPEI6uv ANDCDNNDENNLL DMwasNSToLMEumETEPS]F IL-FOOT SCL-101 MLL 3"50-PACK INST.) v-rx x'-n:s Da.o. 3011017 IP •ter nee• n>.exuc_c. ANGLE$'.,)-I° Ifi. I Mgxt. /F_c erxaxrr iGn i rxFFl .. 6 I 5 I I 1 3 I 2 I I PAGE 09 REVISION:00/05/22 VERSION:V2.0 GF.1Ilk ;oa EcoFasten INSTALLATION GUIDE Far Installers. By Installers. 4 CUT SHEET: CF UNIV L-FOOT MLL 3" - 2012022 e I 0 I a _..._._-__3 _ I z I I 51 ITEM NO. PART NUMBER DESCRIPTION QTY. REV. .:molars DAD I 750720 CLICKFIi LFOOi ASSEMBLY 1 A w xeve¢usmoaorcr,.,w.rem nwl ovvmvi cmmn ,.'\\\.N\ D D Ulli) _ _ ,.. _____ CD • • �� -pi,t _L/ Z r ,;fff .. B /v R 114 Ce THIRD ANGLE PROJECTION ° 'n' 1 / nlM� c'" P s' m n/mz —J mia/me C3 A mrc,i,uo :!9/a: A /37/502 mDANC wrewe"'ANo rznerewvc INNOYATIVl YOVNNMO IYf10W DO NOT SCALE DRAWING DIMENSIONS STOLERANC 3 NONOT A COXRCFMIAI DIMFCI45 TOLERANCES ARE N. CF UNIV L-FOOT MLLJ I.PACKAGE PER"JJ lU22-PCK" xx:./-ew x../.xs sin G.ro. 2012022 IIMU ICF UNIV LOOT OLE 3"SQPACE INSI.) __ xxx:./-oIo xsv-?s A nw A m[.[. ANGLE_+1-I° ia@CI I WEGM: I loll 6 5 I 4 s�.a3>.. I 3 I l II 1111.1111111 Z PAGE 10 REVISION:0005/22 VERSION:V2.4 OF—i INSTALLATION GUIDE o�a EcoFasten For Installers. By Installers. f CUT SHEET: RI COMP SLIDE AL BLK - 2011013 ks:\sl, ITEM NO. PART NUMBER DESCRIPTION QTY. REV. eexmoxs oxeuw .P rzowc I 450092-0 VS 1 ROCKIT SLIDECOMPV3 I DI a xew xaEwsEr eraRw.r lEm acrl orrurvn ..r s 2 53-10001D LAG SCREW.5/16-4WAS i0RHEEARD3",EPDM BACKED 1 C D D C C Pl, ..11 0 Bt _ 1 A IHIRD ANGLE PROJECTION v azl , D`[( A rc rzarC 11 INTERPRET Div JDO Ex.AN NCE INNOVATIVE Y011NIIINRRR- DO NOT SCALE DRAWING v'ZHICE us T pIMENSpNS TCIERANCES AREIN RI COMP SLIDE AL BLK IMILI MOYPIEIPRYANUCONFIDEMl4l INCHEI, ImLL,IMEiERSI I.PACKAGE PER"2011013-PCK" xx..r-:�Go xa.�s .Nv. 2011013 .rrn o...na �m.w .„. uu xc rA (RI COMP SLIDE AL BLK 50-PACK INST.I ......,, ro. r...ww moms, ANGLES;V/-1° IC Y I ATiGm. ire CrI 6 I S I 4 f 3 I 2 I I ..._.. Z 11.11111.1/ PAGE 11 `REVISION:W/RS/22 VERSION:Vi{ GF_IiARV 4 0 EcoFasten INSTALLATION GUIDE For Installers. By Installers. SYSTEM COMPONENTS 4 1 . GF-1 Flashing: All flashing options come with a pre-installed integrated EPDM grommet and one bonded stainless steel EPDM washer. Flashing are available in three k options: 1 . 8 x 12" .032 gauge galvalume with mill or black (kynar painted) finish. Cill 2. 8 x 10" .032 gauge galvalume with black (kynar painted) finish. Z 3. 8 x 12" .032 gauge aluminum with black (kynar painted) finish. O 2. Aluminum Compression Bracket: F.M.I Compatible with a variety of EcoFasten compression brackets. EcoFasten141C compression brackets are made out 6000 series aluminum with options 0 available for mill or black finishes depending on the bracket. 3. Recommended Fasteners 5/16"x4" lag bolts. 3" option also available. 4. Recommended Sealant: LI If required by roof manufacturer, sealant shall be roof manufacturer IIILI approved. CL DELIVERY / STORAGE / HANDLING Cill) Inspect material upon delivery. Notify manufacturer within 24 hours of any missing or defective items. Keep material dry, covered and off the ground until installed. PAGE 12 REVISION:04/05/22 VERSION:WA G Fowl aoa EcoFasten INSTALLATION GUIDE For Installers. By Installers. FLORIDA PRODUCT APPROVAL Approved for any combination of 8"x12" GF-1 flashing with the ClickFit L-foot & Lag Screw. PATENTS Visit www.efpatents.com for patent information. DESIGN REQUIREMENTS 1 . Bracket spacing to be recommended by project engineer. 2. It is important to design new structures or assess existing structures to make sure they withstand retained loads. EXAMINATION 1 . Substrate: Inspect structure on which brackets are to be installed and verify that it will withstand any additional loading that may be incurred. 2. Notify General Contractor of any deficiencies before installing EcoFasten Solar brackets. 3. Verify that roofing material has been installed correctly prior to installing solar attachment bracket. INSTALLATION ' Comply with architectural drawings and project engineer's recommendation for PAGE location of system. Comply with Manufacturer's written installation instructions for 13 installation and layout. EcoFaste„® 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 An Esdec Solar Group Company 1 - 877 - 859 - 3947 I INFO@ECOFASTENSOLAR. COM tntertek Total Quality.Assured. ESDEC, INC. SCOPE OF WORK UL 441 TESTING ON ECOFASTEN'S GF1 REPORT NUMBER 104500499LAX-001 ISSUE DATE 09-DECEM BER-2020 PAGES 6 DOCUMENT CONTROL NUMBER GFT-OP-10a (21-June-2019) © 2019 INTERTEK in torte k 25800 Commerce ntre Drive Lake Forest,CA 92630 USA Total Quality.Assured. Telephone: (949)448-4100 Facsimile: (949)448-4111 SUMMARY REPORT www.intertek.com 09-DECEMBER-2020 Intertek Report No.:104500499LAX-001 Intertek Project No.:G104500499 Yann Schwarz Ph:510 225-0973 ESDEC, Inc. Email:yann.schwarz@esdec.com 28357 Industrial Blvd. Hayward,CA 94545 Subject: Project Summary of the Rain Testing per UL 441 on Ecofasten's GF1 Dear Mr.Yann Schwarz Intertek was contracted by ESDEC, Inc.to perform testing in general accordance with UL 441 on Ecofasten's GF1 photovoltaic(PV) module attachment. Results obtained are tested values and were secured by using the designated test method(s).Testing was conducted at ESDEC's test facility at 28357 Industrial BLVD, Hayward,CA 94545. This letter report represents the summary of our evaluation of the above referenced product(s). UL 441,Safety for Gas Vents,Section 27:Rain Test This letter report does not constitute certification of this product or any opinion or endorsement by this laboratory. If there are any questions regarding the results contained in this report,or any of the other services offered by Intertek,please do not hesitate to contact your dedicated Intertek Project Manager. Completed by: Deep Vora Reviewed by: Samantha Doshi Title: Project Engineer Title: Team Lead-Solar 1Al / Signature: Signature Date December 09, 2020 Date: December 09,2020 Please note:this Letter Report does not represent authorization for the use of any Intertek certification marks. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report.Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Version:21-June-2019 Page 2 of 6 • GFT-OP-10a tntertek ESDEC Inc. 104500499LA%-001 Total Quality.Assured. SUMMARY REPORT St MATERIAL SOURCE/INSTALLATION The test specimen was provided by the client.The specimen was installed onto a Spruce- Pine-Fir wood deck. The test deck measured 3'wide by 3' high and was constructed of#2 Spruce Pine Fir nominal 2x4 lumber. One rafter was centered on deck for bolt attachment. The rafters were attached to the top and bottom plates with 3"long roofing screws. A sheet of nominal 15/32"thick plywood was secured to the studs with#8 x 1-5/8" roofing screws. The test deck was then covered with#30 felt paper and three-tab asphalt shingles. Description/Installation(GF1 by Ecofasten):The test specimen was composed of an 8"x 12"x 0.03125"thick galvalume flashing and a 1-7/8"wide by 3"high extruded aluminum L- foot. The underside of the L-foot was secured with one 5/16"x 4" lag screw with a EPDM backed washer through the L-foot,flashing and into the center rafter of the test deck. The GF1 assembly was installed without sealant. GF1 L-Foot Part numbers covered by this test report are as follows: Part Number Description 3011015 or L-102-3-ANOD BLK L-FOOT L-102 BLK 3" 3011017 or SCL-101-3 ANOD BLK L-FOOT SCL-1010 MLL 3" 3011018 or SCL-101-3 L-FOOT SCL-1010 BLK 3" SFrT±r , LIST OF OFFICIAL OBSERVERS NAME COMPANY Jae Hendrickson ESDEC, Inc. TEST RESULTS The temperature during testing was 18°C(64°F)and the humidity was 57%. The results are tabulated as follows: Test Specimen#1(GF1 by Ecofasten): TITLE OF TEST RESULTS OWED NOTE Water Penetration, Pass No leakage 1, 2, 3 Per UL 441-One hour of water spray General Note:All testing was performed in accordance with the referenced standard(s). Note 1:Tested at 2/12 pitch Note 2:Test results are applicable for asphalt shingle roofs having a slope of 2:12 or greater Note 3:No sealant was used in this test.Any Roofing manufacturer approved sealant is allowed Version:21-June-2019 Page 3 of 6 GFT-OP-10a tntertek ESOEC Inc. 104500499LAx-001 Total Quality.Assured. SUMMARY REPORT PHOTOGRAPHS S. }♦ lJ q9 nay • Photo No.1 Unassembled Test Specimen(including 1 lag screw, 1 flashing,and 1 aluminium L-foot) { SH. Photo No.2 Test Specimen Under Test Version:21-June-2019 Page 4 of 6 GFT-OP-10a • �t�rt` k ES4EOi49. 99rAX_001 1�45��4 Total Quality.Assured. SUMMARY REPORT K / - p di tie- `wy Photo No.3 Test Specimen After Test +" * 45 ;,## 'Sew u... --° ,wet. +' ;}� `} � S."FAT �e 4 ..•{ bra ":7 1 ..ief"' -- f r 'r tl ; F e by T s41`' Tq� I ti • r' Illa Photo No.4 Underside of Test Desk After Test—no visible water penetration Version:21-June-2019 Page 5 of 6 GFT-OP-IOa urttrtck ESDEC Inc. 104500499rAX-001 Total Quality.Assured. SUMMARY REPORT DRAWINGS The test specimen drawings have been reviewed by Intertek and are representative of the test specimen(s) reported herein.Any deviations are documented herein or on the drawings. em 909 4t1t11109 1.4 1 GPI RANI ID. 09 SW% ' t 110S,91u041OU MQ/JO 90,1Cm MA919. S/1e[�111 1/9911l91'!M 1140 [xall O 1Qe Mnp11:L6 +1� • t0 OiolmeL� \ ] MIT t W 404 [>a 1] 2.11 1 [®d ♦ i1.61416M111061111111111PONI m 00^stet a.,^.,.;*,w.°4..sa�a`»"` ECOFASTEN GFI mew, Tju=r Drawing No.1 Ecofasten's GF1 `i' Version:21-June-2019 Page 6 of 6 GFT-OP-10a