Plans (2)
ROOF MOUNT PHOTOVOLTAIC SYSTEM CODES: CONSTRUCTION NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE (IBC) CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND 2018 INTERNATIONAL RESIDENTIAL CODE(IRC) ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2018 INTERNATIONAL MECHANICAL CODE(IMC) ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT 2018 INTERNATIONAL PLUMBING CODE (IPC) POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE 2018 INTERNATIONAL FUEL GAS CODE (IFGC) MOUNTED. RECEIVED 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IFGC) MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. FEB 2 8 2023 2017 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY CITY OF TIGARD DIG ALERT(811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY CITY OF TIGARD EXCAVATION TAKING PLACE BUILDING DIVISION PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER CHECK AHJ AC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE CHECK AHJ AC VICINITY MAP: THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER r'. t UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM a , i0 n a- ' - 5 SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY)AND UL 1741 STANDARDS CLIENT: SW Ls•k 4 r rH.I r i9 `—_ --t' = - JEREMIAH HINKLE =' `, i' INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 16572 SW SNOWDALE ST,BEAVERTON,OR g 7 aP ATTACHED TO THE ROOF USING CONDUIT MOUNT. OFFICE COPY AHl CITY OF TIGARD 5 .r E :' Y UTILITY:PGE-PORTLAND GENERAL ( -cso ELECTRIC ;- 165'2 SW Sn0WGale St, n PHONE:(208)697-9131 Beaverton,OR Q7007 4 EMAIL:JEREMIAH.HINKLE@GMAIL.COM en CITY OF TIGARD FINANCE: OTHER SWk„,,,,� [�14pproved plans REVIEWED FOR ODE COMPLIANCE 9 et .silall be onjC) 1- � SYSTEM: Approved: [✓l SYSTEM SIZE(DC):25X400=10 000kW Sr.'&iltls- :^'. SYSTEM SIZE(AC):7.600 kW @ 240V a P OTC: [ l MODULES:25 X FREEDOM FOREVER: c .1.� � FF-MP-BBB-400 m Permit #: W14�ZDZ3 —b O D OPTIMIZERS:25 X SOLAREDGE S440 INVERTER:SOLAREDGE SE7600H-USRGM f Address: t U5'7z S\pJ S�� .� S,— [sl1] APp'edale Rd Suite #: ' / esC` By: Date: 3f// 23 SITE LOCATION (t( TABLE OF CONTENTS: PV-1 SITE LOCATION VALIDITY OF PERMIT REVISIONS PV-2 SITE PLAN NO. REVISED BY DATE • THE ISSUANCE OF A PERMIT - - PV-2A ROOF PLAN WITH MODULES LAYOUT _BASED ON CONSTRUCTION • PV-2B ROOF AND STRUCTURAL TABLES • DOCUMENTS AND OTHER PV-3 MOUNTING DETAILS DATA SHALL NOT PREVENT freedom PV-4 THREE LINE DIAGRAM THE CODE OFFICIAL FROM REQUIRING THE CORREC' ON FREEDOM FOREVER LLC PV-5 CONDUCTOR CALCULATIONS OF ERRORS.ORSC 105.4 43445 BUSINESS PARK DR#110,TEMECULA, PV-6 EQUIPMENT&SERVICE LIST CA 92590 Tel:(800)385-1075 PV-7 LABELS GREG ALBRIGHT PV-7A SITE PLACARD LIABILITY PV-8 OPTIMIZER CHART The City of Tigard and its ��" ; ,.i.- ,F{'I�' employees shall not be PV-9 SAFETY PLAN responsible for discrepancies CONTRACTOR LICENSE. SUPERVISING MASTER ELECTRICIAN 6576S PV-10 SAFETY PLAN which may appear herein, APPENDIX MANUFACTURER SPECIFICATION SHEETS SITE LOCATION JO03633 12/21/2023I DESIGNM BY I SHEET 'LEGEND: II AC disconnect must be with 10 feet of Utility Meter CHIMNEY PIPE VENT LLJJ MODULES SW SNOWDALE ST CONDUIT -- \ - -__\ • • jSETBACK AC AC DISCONNECT rn O UM UTILITY METER I DRIVEWAY JB JUNCTION BOX INV INVERTER (E) MAIN SERVICE PANEL MSP MAIN SERVICE FENCE/GATE `_I I ROOF AREA: 1950 SG FT PANEL (E) UTILITY METER 4s,1 FENCE/GATE CLIENT: JEREMIAH HINKLE 16572 SW SNOWDALE ST.BEAVERTON,OR AC 97007 INV ❑ ❑ AHJ:CITY OF TIGARD (N)AC DISCONNECT EUTILITY:PGE-PORTLAND GENERAL ELECTRIC PHONE:(208)697-9131 El FINANCE: JEREMIAH.HINKLE@GMAIL.COM FINANCE: OTHER CO (N) 25 FREEDOM FOREVER: FF-MP-BBB-400 - 71- SYSTEM: O / SYSTEM SIZE(DC):25 X 400=10.000 kW J SYSTEM SIZE(AC):7.600 kW @ 240V MODULES:25 X FREEDOM FOREVER: 4'.-4�� OPTIMIZERS o25 X SOLAREDGE S440 INVERTER:SOLAREDGE SE7600H-USRGM / O [SI1[ O /74/7/ /5 1" ROOF LINE REVISIONS NO. REVISED BY DATE PROPERTY LINE — � freedom i J RfVFF FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIG\H�T- OPT 46' 0" ..1, CONTRACTOR LICENSE: ISUPERVISING MASTER ELECTRICIAN 6576S d1k SITE PLAN `�i SCALE: 0.006642 SITE PLAN JOB NO:I DATE: DESIGNED BY:I SHEET: 303633 2/21/2023 L.M. PV-2 LEGEND: TOTAL ROOF AREA: 1950 SQ FT TOTAL ARRAY AREA: 525.48 SQ FT ARRAY COVERAGE: 26.95% CHIMNEY SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT COMP SLIDE POINT-LOAD: 27.68 PIPE VENT LBS r I MODULES CONDUIT 1 SETBACK AC AC DISCONNECT FIRE ACCESS UTILITY METER UM UM MSP PATHWAYS JB JUNCTION BOX AC INV INVERTER INV JB MSP MAIN SERVICE PANEL ROOF AREA:1950 SQ FT CLIENT: JEREMIAH HINKLE 7, ,., 16572 SW SNOWDALE ST,BEAVERTON,OR 97007 AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL ELECTRIC PHONE:(208)697-9131 EMAIL:JEREMIAH.HINKLE@GMAIL.COM FINANCE: OTHER SYSTEM: -On tJJ SYSTEM SIZE(DC):25 X 400=10.000 kW W /// SYSTEM SIZE(AC):7.600 k 240V / / / MODULES:25 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS:25 X SOLAREDGE 5440 / INVERTER:SOLAREDGE SE7600H-USRGM 25 FREEDOM FOREVER: [sl1) / FF-MP-BBB-400 FF-MP-BBB-400 O x/ / / NO. I REVISONS REVISED DATE • . freedom FOREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 JQ]��GREG A L B R I G H T ! e CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S NOTES: ROOF PLAN 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES SCALE: 0.012578 3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF PLAN WITH MODULES LAYOUT JOB NO:I DATE: I DESIGNED BY:I SHEET: 303633 2/21/2023 L.M. PV-2A ROOF DETAILS: TOTAL ROOF AREA: 1950 SQ FT TOTAL ARRAY AREA: 525.48 SQFT ARRAY COVERAGE: 26.95% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT COMP SLIDE POINT-LOAD: 27.68 LBS CLIENT: ROOF AREA STATEMENT JEREMIAH HINKLE 16572 SW SNOWDALE ST,BEAVERTON,OR ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA 97007 AHJ:CITY OF TIGARD ROOF 1 7 26 26 180 270 SQ FT 147.14 SQ FT UTILITY:PGE-PORTLAND GENERAL ELECTRIC ROOF 2 9 26 26 270 600 SQ FT 189.17 SQ FT PHONE:(208)697-9131 EMAIL:JEREMIAH.HINKLEQGMAIL.COM ROOF 3 9 26 26 90 560 SQ FT 189.17 SQ FT FINANCE: OTHER ---- ---- ---- --- ---- SQ FT SQ FT SYSTEM: ---- ---- SQ FT SQ FT SYSTEM SIZE(DC):25 X 400=10.000 kW --- SYSTEM SIZE(AC):7.600 kW @ 240V M ---- ---- ---- ---- ---- SQ FT SQ FT FF-MRLBBB-00 FREEDOM FOREVER: OPTIMIZERS:25 X SOLAREDGE S440 ---- ---- ---- ---- ---- SQ FT SQ FT INVERTER:SOLAREDGE SE7600 RGM [Sill ---- ---- ---- ---- ---- SQ FT SQ FT ---- ---- ---- ---- --- SQ FT SQ FT ---- ---- ---- ---- ---- SQ FT SQ FT REVISIONS NO- REVISED BY DATE freedom FOREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 65763 ROOF DETAILS JOB NO:I DATE: I DESIGNED BY:I SHEET: 303633 2/21/2023 L.M. PV-2B r= 1 1 TABLE 1-ARRAY INSTALLATION II III III III III II II III III III III II MAX MAX RAIL ROOF MAX UNBRACED RAFTER/TRUSS PENETRATION ATTACHMENT OVERHANG(I PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE1 LENGTH(FT.)1 SISTERING PATTERN2 SPACING (IN.IN N.)3 I III III III IIII I III III III III I ROOF 1 26 COMP SHINGLE ECOFASTEN ROCKIT SMART SLIDE 2X4 TRUSS @ 24"OC 6.25' NOT REQ'D STAGGERED 48"OC 16" — — — — — ROOF 2 26 COMP SHINGLE ECOFASTEN ROCKIT SMART SLIDE 2X4 TRUSS @ 24"OC 6.25' NOT REQ'D STAGGERED 48"OC 16" ROOF 3 26 COMP SHINGLE ECOFASTEN ROCKIT SMART SLIDE 2X4 TRUSS @ 24"OC 6.25' NOT REQ'D STAGGERED 48"OC 16" • I STACKED DETAIL For Illustration purposes only I 1.CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION.IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS,NOTIFY ENGINEER OF RECORD IMMEDIATELY. � p 1 2.WHERE COLLAR TIES DR RAFTER SUPPORTS EXIST,CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. 111 IIIIIIDhIlI II 3.WHERE APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. L 9L JL AU JL J CLIENT: JEREMIAH HINKLE 16572 SW SNOWDALE ST,BEAVERTON,OR 97007 AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL I ELECTRIC STAGGERED DETAIL PHONE:(208)697-9131 EMAIL:JEREMIAH.HINKLEIGMAIL.COM For Illustration purposes only FINANCE: OTHER SYSTEM: SYSTEM SIZE(DC):25 X 400=10.000 kW SYSTEM SIZE(AC):7.600 kW @ 240V MODULES:25 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS:25 X SOLAREDGE S440 INVERTER:SOLAREDGE SE7600H-USRGM ISI1] ROCKIT MOUNT ROCKIT MOUNT ROCKIT MOUNT FREEDOM FOREVER: FREEDOM FOREVER: . FF-MP-BBB-400 FF MP BBB 400 FREEDOM FOREVER: FF-MP-BBB400 r� ROOF SURFACE —===ilri ROOF . wo4ommi MEMBRANE ROOF REVISIONS SKIRT �^i MEMBRANE NO. REVISED BY DATE S '' VARIES 2.5"MIN.EMBED. "IN.EMBED. • 2X4 TRUSS 41$24"O.C. . •" freedom 5/16"STAINLESS STEEL LAG ! E R E V E B BOLT OR STRUCTURAL SCREW 5/16"STAINLESS SI EEL LAG WITH 2-1/2"MIN.EMBEDMENT BOLT OR STRUCTURAL SCREW FREEDOM FOREVERR LLC AND FLAT WASHER WITH 2-1/2"MIN.EMBEDMENT 43445 BUSINESS PARK DR#110,TEMECULA, AND FLAT WASHER CA 92590 5/16"STAINLESS STEEL LAG Tel: BOLT OR STRUCTURAL SCREW WITH 2-1/2"MIN.EMBEDMENT GREG ALBRIGnHT AND FLAT WASHER �1y'�� CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S I SOLAR PV ARRAY SECTION VIEW Scale: NTS I ATTACHMENT DETAIL Scale: NTS MOUNTING DETAILS JOB NO,I DATE: I DESIGNED BY:I SHEET: 303633 2/21/2023 L.M. PV-3 BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 32.00A @ 240V 32.00 X 1.25 = 40.00AMPS 40A BREAKER- OK SEE 705.12 OF CHECK AHJ AC 225 X 1.20 = 270 270 - 200 = 70A ALLOWABLE BACKFEED CLIENT: JEREMIAH HINKLE 16572 SW SNOWDALE ST,BEAVERTON,OR 97007 AHJ:CITY OF TIGARD (E)UTILITY PGE-PORTLAND GENERAL (E)225A RATED — METER ELECTRIC MAIN SERVICE PANEL PHONE:(208)697-9131 1PH.120/240V 60HZ EMAIL:JEREMIAH.HINKLE@GMAIL.COM (E)200A 12P MAIN — ® FINANCE: OTHER BREAKER (TOP FED) SYSTEM: SYSTEM SIZE(DC):25 X 400=10.000 kW STSYSTEM SIZE(AC):7.600 kW @ 240V 13 STRING-2 FREEDOM FOREVER. 12 FREEDOM FOREVER: MODULES:25X FREEDOM FOREVER: FP-MP-BBB-400 FF-MP-BBB-400 1 o FF-MP-BBB-400 I I I I I (N)soIAREDGE /`• OPTIMIZERS:25X SOLAREDGE S440 SE7600H-USRGM Islt] .� INVERTER:SOLAREDGE SE7600H-USRGM TO OTHER LOADS INVERTER (N)BOA RATED a-#10 AWG,THWN-2 — \kCI EATAC DISCONNECT ONDG222URB(OR1-#10 EGO,THWN-2 IN 3l4"OR EQUDIVALENT)r An v= -- r2 --- 4 = -- I I1.4_ LARGER EMT CONDUIT I r IS KNIFE BLA,ULOCKABLE, (N)40A/2P PV BREAKER NEMA 3R,UL LISTED L TO UTILITY I _ �p7y� 1 `L JUNCTION — -_ d bo o --UNDERGROUND _ BOX �� _ ✓✓✓III o _ FEED SOLAREDGE S440 SOLAREDGE S440 — I —RAPID POWER OPTIMIZERS POWER OPTIMIZERS I SHUTDOWN I REVISIONS a-,no AWG,PV WIRE SWTCH L_ NO. REVISED BY DATE 1-#5 AWG IN FREE AIR OR 3-#8 AWG,THWN-2 —3-#B W AWG,THN-2 #10 AWG MUST BE IN EMT CONDUIT 1-#10 EGC,THWN-2 1-#10 EGC,THWN-2 _ _ - IN 3/4'OR LARGER EMT IN 3/4'OR LARGER EMT CONDUIT CONDUIT - - v. freedom GOREV ER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG AL'BR IGnHT J)` 4 CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS JOB NO I2 DATE:E I DESIGNED BY:I SHEET: VOLTAGE DROP CALCULATIONS DC VOLTAGE(V) CURRENT(A) LENGTH (FT) VOLTAGE DROP(%) WIRE SIZE RACEWAY , 481.91 18.75 55 0.54% 10 3/4" EMT AC VOLTAGE(V) CURRENT(A) LENGTH (FT) VOLTAGE DROP(%) WIRE SIZE RACEWAY 240 40 6 0.16% 8 3/4" EMT NOTE: PER ETO REQUIREMENTS,VOLTAGE DROP CALCULATIONS WILL BE NO GREATER THAN 2%. WIRE SCHEDULE CLIENT: JEREMIAH HINKLE STARTING ADJUSTMENT MAXIMUM 16572 SW SNOWDALE ST,BEAVERTON,OR STARTING TEMPERATURE ADJUSTED 97007 AWG CURRENT FACTOR FOR CURRENT AHJ:CITY OF TIGARD RACEWAY CONDUCTOR ALLOWABLE CORRECTION CONDUCTOR EQUIPMENT WIRE APPLIED TO MORE THAN 3 APPLIED TO UTILITY:PGE-PORTLAND GENERAL # QTY. AMPACITY @ 90°C FACTOR AMPACITY ELECTRIC SIZE CONDUCTORS CONDUCTORS CONDUCTORS 310.15(B)(16) IN RACEWAY 310.15(6)(2)(a) 310.15(B)(3)(a) @ 90°C IN RACEWAY PHONE:(208)697-9131 EMAIL:JEREMIAH.HINKLE@GMAIL.COM 1 DC MODULE TO OPTIMIZER 2 10 40 17.24 1 1 40.00 21.55 FINANCE: OTHER 2 DC OPTIMIZER TO JUNCTION BOX 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER 4 10 40 15.00 1 0.8 32.00 18.75 SYSTEM: SYSTEM SIZE(DC):25 X 400=10.000 kW 4 AC INVERTER TO AC DISCONNECT 3 8 55 32.00 1 1 55.00 40.00 SYSTEM SIZE(AC):7.600 kW©240V MODULES:25 X FREEDOM FOREVER: 5 AC AC DISCONNECT TO POI 3 8 55 32.00 1 1 55.00 40.00 FF-MP-BBB-400 OPTIMIZERS:25 X SOLAREDGE S440 INVERTER:SOLAREDGE SE7600H-USRGM ---- [SI1j REVISIONS NO. REVISED BY DATE ___ . freedom FORE V E R FREEDOM FOREVER LLC --- 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590__ Tel:(800)385-1075 --- GREG ALBRIGHT __- CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH AC 690.8. CONDUCTOR CALCULATIONS JOB NO:I DATE: I DESIGNED BY:I SHEET: 303633 2/21/2023 L.M. PV5 OCPD SIZES: SERVICE LIST: 40A BREAKER NONE MATERIAL LIST: QTY. PART PART# DESCRIPTION 25 MODULES PV-110-400 FREEDOM FOREVER:FF-MP-BBB-400 25 OPTIMIZERS S440 SOLAREDGE S440 POWER OPTIMIZER-FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 2 CONNECTORS 240-300 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(FEMALE) 2 CONNECTORS 240-301 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(MALE) 1 INVERTER INV-120-763 SE7600H-US[SI1]RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 321-060 60A RATED 240VAC NEMA 3R UL LISTED CLIENT: JEREMIAH HINKLE 44 ROOF ATTACHMENT 1 RAC-265-002 ROCKIT COMP SLIDE 16572 SW SNOWDALE ST,BEAVERTON,OR 18 TRIM 1 241-253 ROCKIT TRIM COMP DARK 97007 48 SLIDER 1 261-603 ROCKIT SLIDER COMP DARK AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL 14 BONDING CLAMP 1 221-100 N/S BONDING CLAMP ELECTRIC 6 BONDING CLAMP 1 241-404 TRIM BONDING CLAMP PHONE:(208)697-9131 27 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY EMAIL:JEREMIAH.HINKLE@GMAIL.COM FINANCE: OTHER 15 SPLICE 1 261-604 ROCKIT SPLICE 4 ATTACHED SPLICE 1 211-101 ATTACHED SPLICE 8 INCH 21 TRIMRAIL 1 261-606 TRIMRAIL UNIV CLIP W/HDW SYSTEM: 7 TRIM SPLICE 1 281-605 TRIM SPLICE DRK SYSTEM SIZE(DC):25 X 400=10.0001(01 SYSTEM SIZE(AC):7.600 kW©240V 11 TRIMRAIL 1 211-115 TRIMRAIL UNIV DRK MODULES:25 X FREEDOM FOREVER: 25 GROUND LUG 1 260-585 ILSCO GROUND LUG FF-MP-BBB-400 OPTIMIZERS:25 X SOLAREDGE S440 25 TRIM END CAPS 1 221-200 ROCKIT TRIM END CAPS INVERTER:SOLAREDGE SE7600H-USRGM 44 FLASHING 1 RAC-265-001 GF-1 FLASHING GLV BLK BX10 [S11] REVISIONS NO. REVISED BY DATE 2• freedFoEm FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 65768 EQUIPMENT&SERVICE LIST JOB NO:I DATE: I DESIGNED BY:I SHEET: 303633 2/21/2023 L.M. PV-6 - WARNING: "WARNING" NOTES: POWER SOURCE OUTPUT M DUAL POWER SOURCES 1. AC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS CONNECTION SHOWN HEREON. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: DO NOT RELOCATE THIS RATED AC OUTPUT CURRENT - 32.00 AMPS A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OVERCURRENT DEVICE. j AC NORMAL OPERATING VOLTAGE - 240 VOLTS B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. 705.12(B)(2)(3)(b) - =r ` C. ARIAL FONT. 690.54 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN SOLAR PV SYSTEM EQUIPPED THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. WITH RAPID SHUTDOWN 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO 0.AX ELECTRIC PV PANELS SHUT DOWN PV SYSTEM AND REDUCE SHOCK in HAZARD IN THE ARRAY - 690.56(c)(1)(A) "WARNING" CLIENT: ELECTRICAL SHOCK HAZARD. JEREMIAH HINKLE 16572 SW SNOWDALE ST,BEAVERTON,OR TERMINALS ON BOTH LINE AND LOAD SIDES 97007 AHJ:CITY OF TIGARD MAY BE ENERGIZED IN THE OPEN POSITION. UTILITY:PGE-PORTLAND GENERAL ELECTRIC PHONE:(208)697-9131 PV METER -:! EMAIL:JEREMIAH.HINKLE@GMAIL.COM a 690.13(B) FINANCE: OTHER PV SYSTEM DC DISCONNECT SYSTEM: MAXIMUM VOLTAGE 480V SYSTEM SIZE(DC):25 X400=10.000 kW SYSTEM SIZE(AC):7.600 kW©240V PV SYSTEM AC DISCONNECT MAXIMUM CIRCUIT CURRENT: 20A MODULES:25%FREEDOM FOREVER: FF-MP-BBB-400 c� MAX RATED OUTPUT CURRENT OF OPTIMIZERS:25 X SOLAREDGE 5440 a RATED AC OUTPUT CURRENT - 32.00 AMPS INVERTER:SOLAREDGE SE7600H-USRGM AC NORMAL OPERATING VOLTAGE 240 VOLTS AA :CONTROLLER OR DC-TO-DC [sin CONVERTER: 15A 690.15,690.54 690.53 ARRAY IMP RAPID SHUTDOWN SWITCH FOR _A_ SOLAR PV SYSTEM INVERTER I III REVISIONS ,Jvisoiliiit } ` DC ' I/B ' NO. REVISED BY DATE 690.56(C)(3) � A v! �` HIllhilal_ AC 690.31(G)(3)&(4) • . freedom F 0 0.f V f 0. MAXIMUM VOLTAGE 480 U d. FREEDOM FOREVER LLC 'c 43445 BUSINESSE PARK R L TEMECULA, MAXIMUM CIRCUIT CURRENT 20 A RNINGCA92590 PHOTOVOLTAIC POWER SOURCE Tel:(800)385-1075 MAX DC-DC CONVERTER 15 A GREG ALBRIGHT OUTPUT CURRENT EVERY 10'ON CONDUIT AND ENCLOSURES / � J1{4� CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S LABELS JOB 303633 12/21/20231 DESIGNED BY.I SPV.7 CAUTION . ■ POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH CLIENT: DISCONNECTS AS SHOWN JEREMIAH HINKLE 16572 SW SNOWDALE ST,BEAVERTON,OR 97007 AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL ELECTRIC PHONE:(208)697-9131 SW SNOWDALE ST EMAIL:JEREMIAH.HINKLE©GMAIL.COM FINANCE: OTHER MAIN SERVICE PANEL SYSTEM: SYSTEM SIZE(DC):25 X 400=10.000 kW \/ SYSTEM SIZE(AC):7.600 kW c 240V UTILITY METER MODULES: FREEDOM FOREVER: OPTIMIZERS:25 X SOLAREDGE S440 INVERTER:SOLAREDGE SE7600H-USRGM AC DISCONNECT - ' ism INVERTER EQUIPPED — WITH RAPID SHUTDOWN 25 PV MODULES REVISIONS WARNING NO REVISED BY DATE TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL freedom FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT NOTES: �4 1. AC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. CONTRACTOR LICENSE 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: SUPERVISING MASTER ELECTRICIAN 6576S A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. SITE PLACARD 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. JOB No:I DATE: I DESIGNED BY:I SHEET. 303633 2/21/2023 L.M. PV-7A 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 SOLAREDGE OPTIMIZER CHART JIMSP 1 ✓ JB 2 3 CLIENT: JEREMIAH HINKLE 16572 SW SNOWDALE ST.BEAVERTON,OR 97007 4 AHJ:CITY OF TIGARD UTILITY:PGE-PORTLAND GENERAL ELECTRIC PHONE:(208)697-9131 EMAIL:JEREMIAH.HINKLE@GMAILCOM FINANCE: OTHER 5 SYSTEM: SYSTEM SIZE(DC):25 X 400=10.000 kW SYSTEM SIZE(AC):7.800 kW@ 240V MODULES:25 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS:25 X SOLAREDGE S440 6 INVERTER:SOLAREDGE SE7800H-USRGM 1S111 7 REVISIONS NO. REVISED BY DATE 8 _ freedom 9 FOREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)365-1075 GREG ALBRIGHT 10 / ' CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S OPTIMIZER CHART JOB NO. DATE: DESIGNED BY: SHEET: 303633 2/21/2023 L.M. PV-8 SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. © PERMANENT ANCHOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE&MAKE NOTES ON TO TEMPORARY ANCHOR THE JHA SHEET INCIDENT REPORTING: I IL INSTALLER LADDER INJURIES-CALL INJURY HOTLINE (855) 400-7233 M B JUNCTION / COMBINER BOX *If injury is life threatening, call 911 first THEN the Injury Hotline NV JB S STUB-OUT NON-INJURIES- USE MOBILE INCIDENT REPORTING (Auto, Property Damage, Near Miss) /X\\ / SKYLIGHT 0 " 'J..• ii NO LADDER ACCESS (STEEP 1r_ Fes-1 I GRADE OR GROUND LEVEL ar LME J al- . I , OBSTRUCTIONS) CLIENT: • % i o JEREMIAH HINKLE El {,Z IV• 16572 SW SNOWDALE ST.BEAVERTON,OR RESTRICTED ACCESS 97007 AHJ:CITY OF TIGARD UTILITY.PGE-PORTLAND GENERAL NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: ELECTRIC CONDUIT PHONE:(208)697-9131 EMAIL:JEREMIAH.HINKLE@GMAILCOM NAME: FINANCE: OTHER ADDRESS: (12 GAS SHUT OFF SYSTEM: SYSTEM SIZE(De):25 X 400=10.000 kw NEAREST HOSPITAL: / el WATER SHUT OFF SYSTEM SIZE(AC):7.600 kVV@240V I MODULES. 25 X FREEDOM FOREVER: M / O SERVICE DROP IINV,RTER:SOLAREDGE SE7600H-USRGM NAME: y OPTIMIZERS:25 ADDRESS: O POWER LINES SAFETY COACH CONTACT INFORMATION: NAME: PHONE NUMBER: BREAK AND WATER LOG REVISIONS NO. RE EVBY DATE ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS - _ PLAN FOR WORKING SAFELY COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME SIGNATURE ` } freedom NAME 0800HRS 0900HRS 1000HRS 110DHRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS - OREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT A CONTRACTOR LICENSE: SUPERVISING MASTER ELECTRICIAN 6576S SAFETY PLAN DATE: TIME: • JOB NO.I DATE. I DESIGNED BY:I SHEET. 303633 2/21(2023 L.M. PV-9 • JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access • Crew leader responsible for communication with the client: Heat Related Illness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE • Ladders must be inspected before each use. • Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) • Extension ladders must be set up on a firm and level surface at • Client and public is excluded from work area by barricades(N/A, fresh, pure,and suitably cool.The water shall be located as Define the Hazard: Method/steps to prevent incident: a 4-to-1 rise to run angle(or 75 degrees)and the top must be Yes, No): close as practicable to the areas where employees are working. secured to the structure. Extension style ladders placed on Water shall be supplied in sufficient quantity at the beginning of uneven, loose or slippery surfaces must additionally have the Training and Pre-Job Safety Briefing the work shift to provide at least one quart per employee per base firmly anchored or lashed so the base will not slip out. • All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift. Employees may begin the • Extension ladders must be used with walk-through devices or of this project and review this HJA during a pre-job briefing, and shift with smaller quantities of water if they identify the location Define the Hazard: Method/steps to prevent incident: the ladder must extend 36"above the stepping off point. their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to • A-frame ladders must only be climbed with the ladder spreader plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour.The bars locked in the open position;A-frame ladders shall not be project. frequent drinking of water shall be encouraged. climbed while in the closed position (ex, closed and used while • Shade shall be present when temperature exceeds 80 degrees leaned against a structure). • Crew leader(name/title): Fahrenheit.When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: • Additional notes: 80 degrees Fahrenheit,employees shall have and maintain one • Crew member(name/title): or more areas with shade at all times. Mobile Equipment • New employees must be acclimatized. New employees will be • Only Qualified operators will operate equipment; operators must • Crew member(name/title): monitored by their Crew Leader(site supervisor)for the first two maintain a certification on their person for the equipment being (2)weeks of employment or longer when necessary. Define the Hazard: Method/steps to prevent incident: operated. • Crew member(name/title): • Employees will be allowed and encouraged to implement • Type(s)of mobile equipment(Type/Make/Model): scheduled breaks during each shift. Employees must take • Crew member(name/title): cool-down breaks in the shade any time they feel the need to do • Qualified operator(s): so to protect them from overheating. Supervisors are • Crew member(name/title): REQUIRED to allow employees any break period they need CLIENT: Material Handling and Storage during high heat conditions. JEREMIAH HINKLE • Materials will be staged/stored in a way that does not present a Airborne Contaminants: • Cool Vests are encouraged for all employees at all times during 16572 SW SNOWDALE ST.BEAVERTON,OR hazard to client, personnel or public. Materials stored on the • Asbestos-containing(Transite) piping (ACP)-Do not disturb periods of high heat. 97007 AHJ:CITY OF TIGARD roof will be physically protect from failing or sliding off. (move, drill, cut fracture,etc.) • Identify the location of the closet Occupational/Industrial Clinic UTILITY:PGE-PORTLAND GENERAL • Asbestos-containing thermal insulation (ACI)and or Hospital in case a crew member becomes ill. ELECTRIC Fall Protection Asbestos-containingduct wrapping ACdo not disturb, no PHONE'.(2013)697-9131 PP fd( )M- EMAIL:JEREMIAH.HINKLE@GMAIL.COM • A site-specific plan for fall prevention and protection is required attic or crawlspace access is allowed if work to be performed What is the specific plan to provide and replenish sufficient water for FINANCE: OTHER prior to starting work and must remain onsite at all times until could cause exposure to personnel, client or public. all employees on site? work is complete;a fall rescue plan must be outlined and • If offsite replenish is necessary, where will you go to replenish discussed amongthe crewprior to work start. • Ifyes, list specific tasks andprotection inplace: water(location/address): SYSTEM: p ( ) SYSTEM SIZE(DC):25 X 400=10.000 kW • First-person-Up(FPU) must install their anchor and connect SYSTEM SIZE(AC):7.600 kW @ 240V • Who will replenish the drinkingwater(name): MODULES:25 X FREEDOM FOREVER: before any other task, including installing other anchors. The P FF-MP-BBB-400 Last-Person-Down (LPD) must be the only person on a roof OPTIMIZERS:25 X SOLAREDGE S440 INVERTER:SOLAREDGE SE7600H-USRGM uninstalling fall protection. Restroom facilities [S111 • FPCP (name and title): • Employees shall have access to restroom facilities with • FPU and LPD(name and title): hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give Electrical Safety permission, location of suitable restroom facilities with • The Electrical Qualified Person(EQP) is required onsite to hand-washing stations offsite will be provided.The onsite perform electrical work. supervisor will identify location and make arrangements to • All electrical work will be performed with equipment in an ensure all employees have access at any point. REVISIONS electrically safe condition(de-energized) unless approval has • Restroom facilities will be(circle one): Onsite-Offsite NO. REVISED BY DATE been granted prior to work. Weather and Environment • If Offsite, add location name and address: - . • Service drops and overhead electrical hazards will be indentified • The site supervisor shall forecast the weather conditions at the - . _ and protected from contact, as neccessary. job site, prior to crew arrival, in order to mitigate any hazards Incident Reporting Procedure - • EQP(name and tile): associated with inclement weather(heat,cold,wind, rain,etc.) • Contact your Site Supervisor • The site supervisor will utilized a portable wind meter Name: freedom Public Protection (anemometer)to verify actual onsite wind conditions, by checking C, o a E v E a • The safety of the Client and Public must be maintained at all at the ground and on any elevated work surface(ex, rooftop) Phone: FREEDOM FOREVER LLC times. prior to work start,at midday and prior to solar panel staging on a 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 • The Client and the Public shall be prevented from entering the roof. • Contact your Manager Tel:(800)385-1075 work zone through the use of barriers and/or signage,as • Elevated work involving the moving or maneuvering of solar Name: GREG ALBRIGHT required. panels shall cease at 25mph (sustained wind) until wind • Company, Client and Public property shall be protected from subsides. Phone: / {> falling objects. • Forecasted weather maximum temp(degrees f): • Pets includin dogs)shall be secured bytheir ownersprior to • Contact your Site Supervisor CONTRACTOR LICENSE. ( 9 SUPERVISING MASTER ELECTRICIAN 65765 work start. Name: • The Client should not leave pets,family members, or others in charge or care of Employees, Contractors, or Temporary Phone: Workers. With:Your full name, phone number, office location, brief description SAFETY PLAN of what happen and when. JOB NO:I DATE: I DESIGNED BY:I SHEET, 303633 2/21/2023 L.M. PV-10 • ee freedom° freedom ® J M 0 D U L E • • 1134x2 ELECTRICAL CHARACTERISTICS 4� III IIIII '� IIIIIII1111111111' WIIII FOREVER Characteriatica FF-MP-BBB-400 II�11 (IIIIIIII IIll1111III1111 111111illllll I�111 IIIIIII (IIIII Frame Profile Maximum Power(Pmax) 400W 1111 IIIUIII IWIII I�11 111111111 IIIIIII III, IIIIIIII — + Maximum Power Voltage(Vmp) 31.01 V II[nll IIIII Hill 1 IIIIIII i IIIII I l L Maximum Power Current(Imp)[A) 12.90A 1 IIIII r=-�,? ���1I�''����1I0�0'�0;;�0;;0;t;II;p�� Open Circuit Voltage(Voc)[VI 37 04V n LLJO._tl IIIIIII R �WllYYW. Short Circuit Current(Isc)[A) 13.79A REM M IIIII ��U 11111111 Module Efficiency 20.48% (IIIIIIII IIIIIIII'1 l IIIII 111111111 I111 Power Tolerance 0/+5W Lilillllt 1111111 35[1.38] 1111T1111112111111Irradiance of 1000W/m2,AM'..5, r . STC Cell Temperature 25°C iMifiliallIMII . J�fl!llWWUII�IOWWWV11�ImWWW� MECHANICAL CHARACTERISTICS Front . [ Cell Type Mono perc,182 mm-half cells,108(6x9-6x9) III111111111111 • ' ! Weight 22.1 kgs(48.7 Ibs) 35 Dimension 1722 x 1134 x 36 mm(67.80 x 44.65 x 1.38 in) r r 11d4.oMM ' ' Front Glass 3.2 mm(.13 in) — now ` L / Junction Box IP68(3 Bypass Diodes) 1 Output Cables 1200 mm(47.24 in) f j )11�( �j i I �l I I Connector Staubli MC4 I'I I f) 1I 1(I1 I Frame&Installation Anodized aluminum profile 1 I t Product Label OPERATIONS CHARACTERISTICS ( Operational Temperature -40°C-+85° 1f Max System Voltage 1500V • Max Series Fuse Rating 25A I! ,f 0 5 Il [ Safety Class Class II �"e ri ++11 . I �, i11 r , 1r � Fire Rating Type 1 ) m MECHANICAL LOADING Snow Load 5,400Pa(1131b/ft2) Rear Side Design Load 2,400Pa(501b/ft2) PACKAGING INFORMATION • Container 20'GP 40'HC Pallets per Container 6 26 / • • AOMM Panels per Container 186 806 Back Side Panels per Pallet 31 31 Packaging Bon Weight 879 kg(14971bs) CURRENT-VOLTAGE CURVE Panels per Pallet 1785 x 1130 x 1180 mm (70.28 x 44.49 x 46.46 in) 14 14 1000W/r e 12 — 10°C "1 12 TEMPERATURE RATINGS ▪ 10 — 40C 1l C 10'600W/m= 55C Temperature Coefficient of P,, -0.350%/°C ▪ 6 70°C d s 61 �0% 0 ® Temperature Coefficient of V•° 0.275%/°C t j t� 4 400W/m' a warranty °npnt Temperature Coefficient of l,< +0.045%/°C --- ) Marrenty warranty 2 2 200W/m' °�'•,<,_u� Nominal Operating cell Temperature(NOCT) 42°C±2°C 0 s°°x a0 10 g1 30 40 0 10 20 30 40 •^ C E ❑ Voltage(V) Voltage(V) 3 ux UL61730'UL61215 ISO 9001 i16014001 Freedom 400Ni Module 7acashee'. Version No.PF-MP-888-400 ° 1 6 2 b Year Intertek Intertek Total Quality.Assured. Total Quality.Assured, . ,,. . ., ..,, ,, CERT IFICAT E CERTIFICATE . lk Photovoltaic (PV) Module Safety Qualification - Part 2: Requirements for Testing [CSA C22.2U61730- This certificate confirms the model(s)for the product listed are in compliance and authorized to bear the Certification Mark(s)shown below when 2:2019 Ed.2] made in accordance with the conditions set forth in the Certification Agreement and Listing Report.This document is for use with the Design Light Consortium or California Energy Commission application only. Terrestrial Photovoltaic(Pv) Modules- Design Qualification And Type Approval-Part 1:Test Requirements [UL 61215-1:2017 Ed.1] Basic Listee: PT IDN SOLAR TECH Multiple Listee: Freedom Forever Procurement LLC KOMPLEK KABIL INDONUSA ESTATE, Terrestrial Photovoltaic(PV) Modules-Design Qualification And Type Approval-Part 1-1:Special Address: BLOK A NOMOR 19B, BATU BESAR, Address: 43445 Business Park Drive,Suite 110, Requirements For Testing of Crystalline Silicon Photovoltaic(PV) Modules [UL 61215-1-1:2017 Ed.1] Batam Temecula,CA 92590 Terrestrial Photovoltaic(Pv) Modules-Design Qualification And Type Approval- Part 2:Test Indonesia Country: Country: USA Procedures[UL 61215-2:2017 Ed.11 Product: Crystalline Silicon Photovoltaic(PV) Modules Party Authorized to Apply Label: PT IDN SOLAR TECH Report Issuing Office: Intertek Testing Services Shanghai Limited Brand Name: Freedom Forever /!. MULTIPLE LISTEE 12 MODELS BASIC LISTEE MODELS ,, Control Number: 5019087 Authorized by: ,so // �" FF-MP-BBB-followed by 365, 370, 375 or 380. NUSA120H-followed by 365, 370, 375 or 380; followed f.r L. Matthew Snyder, Certification Manager Models: by MB. FF-MP-BBB-followed by 395,400,405 or 410. NUSA108H-followed by 395,400,405 or 410;followed VALID LISTING MARKS by MB. cETAUS Intertek This Certificate of Compliance is for the exclusive use of Intertek's Client and is provided pursuant to the Certification Agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the Agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the Agreement,for any loss,expense or damage occasioned by the use of this Certificate.Only the Client is authorized to permit copying or distribution of this Certificate and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the Agreement and in this Certificate.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the Agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights,IL 60005 Telephone 800-345-3851 or 847-439-5667 Photovoltaic(PV) Module Safety Qualification-Part 1: Requirements for Construction [UL 61730- 1:2017 Ed.1+R:30Apr2020] Standard(s): Photovoltaic(PV) Module Safety Qualification-Part 1: Requirements for Construction [CSA C22.2t#61730-1:2019 Ed.2] Photovoltaic(PV) Module Safety Qualification-Part 2: Requirements for Testing [UL 61730-2:2017 Ed.1+R:30Apr2020] Certificate for Report: 200900855SHA-001 Page 1 of 2 Certificate Issued:June 16, 2022 Certificate for Report: 200900855SHA-001 Page 2 of 2 Certificate Issued:June 16, 2022 Power Optimizer -CI For North America Power Optimizer 5440, 5500 S440 S500 Unit For North America INPUT Rated Input DC Powerf0 440 500 W Absolute Maximum Input Voltage(Voc) 60 Vdc S440, S 500 m MPPT Operating Range 8-60 Vdc Maximum Short Circuit Current psc)of Connected PV Module 14.5 I 15 Adc Maximum Efficiency 9 .6 % Weighted Efficiency 99. % Overvoltage Category II 2 C OUTPUT DURING OPERATION 7 Maximum Output Current 15 Adc YEAR 0 Maximum Output Voltage 60 Vdc WARRANTY OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer I 1+/-0.1 I Vdc • STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class-,U II safety),UL1741 Resistant Material UL94 V-0,UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS N Maximum Allowed System Voltage 1000 1z9x153 x30Vdc Dimensions(W xL x H) /5.07 z6.02 x1.18 men/in Weight(including cables) 655/1.5 gr/lb Input Connector MC4PI Wire th 0.1/0.32 m/ft Output Connector MC4 Output Wire Length (+)2.3,(-)0.10/(+)7.54,(-)0.32 m/ft Operating Temperature Rangem -40 to*85 .0 Protection Rating IP68/Type6B Relative Humidity 0-100 % (1)Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power,Modules with up to*5%power tolerance are allowed (2)For other connector types please contact SolarEdge (3)For ambient temperature above*70°C/*158°F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Single Phase Three Phase for 208V Three Phase for Inverter HD-Wave grid 277/480Vgrid PV power optimization at the module level Minimum String Length 5440,5500 8 14 18 (Power Optimizers) Maximum String Length(Power Optimizers) 25 5ow / Specifically designed to work with SolarEdge / Faster installations with simplified cable management Maximum Nominal Power per String 5700 MOO with SE7600-US-SE1k 00 U7 6000 2750 W residential inverters and easy assembly using a single bolt Maximum Allowed Connected Power per String m One String 7200W (Permitted only when the difference in connected power between Refer to Footnote 5 15,000W strings is 1,000W or its) Two strings or more 7800W / Detects abnormal PV connector behavior, / Flexible system design for maximum space utilization Parallel Strings of Differentlengths or oden ations y (4)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement preventing potential safety issues* (5)If the inverters rated AC power 3 nammum nominal power per string,then the maximum power per sting will be able to reach up to the inverters maximum input DC power.Refer to:https:/Mww.solaredge.mm/ saes/default/files/se-power-optinzer-single-stn ng-design-application-note.pdf / Compatible with bifacial PV modules (6)R is not allowed to mix S-series and P-series Power Optimizers in new installations / Module-level voltage shutdown for installer and / l firefighter safety / Meets NEC requirements for arc fault protection(AFCI) 0 and Photovoltaic Rapid Shutdown System(PVRSS) , �s `� / mom— V� / Superior efficiency(99.5%) , QaaW 40' / Mitigates all types of module mismatch loss, 41 from manufacturing tolerance to partial shading .' r, e lc55 ( ;o Expected availability in 2022 /2 c solaredge.com solar • . ! ': CO ®SolarEdge Technologies.Inc.All rights.eened.SOWIEDGE,the SolerEdge logo,OPTIMIZED BY WDIAREDGE ere trademarks or registered trademarb of solarrdge Technologies. CC"' b5 RoHS Inc Abatises bedemeks mentioned herein are tredemarb of their respective owners.Date:FebnaryR2022 U500001B-NA.Subject to change without notice. Intertek • / Single Phase Inverter with HD-Wave Technology _ for North America Single Phase Inverter ZSE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ Technology < SE7600H-US / SE10000H-US / SE11400H-US with HD-Wave T ec gy M MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US for North America WITHAPPLICABLEINVERTERS SEXXXXH-XXXXXBXX4 WITH PARTRTNUMBER SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / OUTPUT SE7600H-US / SE10000H-US / SE11400H-US Rated"`Power Output 3000 3300@28V 5000 °� 2oeV 7600 10000 1 1400 @z 8V VA 3800 @ 208V 6000 @ 240V 11400 @ 240V Maximum AC Power Output 3000 5000 7600 10000 VA 3300 @ 208V 5000 @ 206V• 10000 @ 208V �YEAR AC output voltage Min-Nom.-Max. VEAR • (211-240-264) • • • Vac O s WARRANTY AC Output Voltage Min.-Nom.-Max. - • I - _ - r' Vac (183-208-229) • AC Frequency(Nominal) 59.3-60 60.Sr^ • Hz • 0 Maximum Continuous Output Current©240V 12.5 16 21 25 32 42 • 47.5 A • Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V O • Power Factor 1,Ad;cstable-0.85 to 0.85 • • GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT solaria ...ND— solar l! ,+I'11Dwe.. Maximum DC Power©240V 4650 5900 7750 9300 11800 15500 • 17650 W • 0 • ® Maximum DC Power @208V - 5100 - 7750 - - 15500 W _ —it r .. . !r—r __7 , -'-'- ', - Transformer-less,Ungrounded Yes 0 0 Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc 0 ® Maximum Input Current @240Vw 8.5 10.5 13.5 16.5 20 27 30.5 Adc 0 Maximum Input Current @208Vm - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc 0 • 0 0 Reverse-Polarity Protection Yes ' 111.1 - - Ground-Fault Isolation Detection 600kv Sensitivity Maximum Inverter Efficiency 99 99.2 % 99 @ 240V % CEC Weighted Efficiency 98.5 @ 208V Nighttime Power Consumption <2.5 ' W Optimized installation with HD-Wave technology (1)For other regional settings please contact SolarEdge support (2)A higher current source may be used;the inverter will limit its input current to the values stated / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors I Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional: Faster installations with built-in consumption metering (1%accuracy) and / Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5%accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com SO l a l' / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US 5E7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces R5485,Ethernet ZigBee(optional),Cellular(optional) • Revenue Grade Metering,ANSI C12 20 Optionaiw Consumption metering • Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for local Connection • Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690.12 STANDARD COMPLIANCE • Safety UL1741,UL1741 SA,UL16998,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/4 of Stings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) '.. 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60to Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N.5EnonH-US000BNC4;inverter with Revenue Grade Production and Consumption Meter P/N:SEioc gH US000BN14_For consumption metering,current transformers should be ordered separately:SEACT0750-200NA-20 or SEACT0750 400NA-20.20 units per box (4)Full power up to at leas 50-C/122-F;for power de-rating information refer to:https://www.solaredge.com/sites/defaulVSles/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverters existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring Grid o &L1 N L2 i•_r. Shielded CATSe cable I I ./►-4 Lt -eat- I I N 1►':i 1 II L2 l J v AC Conduit O SolarEdge Technologies,Inc.All fights reused.SOLAREDGE,the SolarEdge logo,OPTIMIZED aV SOLAREDGE are trademarks or registered trademarks of solarEdge Technologies,Inc.AS RoH S other trademarks mentioned herein are trademarks of their respective owner Date:12/2020/Vt1ENG NAM.Subject to change without notke. ©2016 Eaton. All rights reserved. pe.eaton,corn r F ' a Eaton general duty non-fusibleit . safety safety switch DG222URB • UPC:782113144238 Dimensions: • Height: 14.38 IN • Length: 7.38 IN • Width: 8.69 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: Non-fusible, single-throw • Amperage Rating: 60A • Enclosure: NEMA 3R, Rainproof • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non-fusible • Number Of Poles: Two-pole • Number Of Wires: Two-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG222URB Certifications: • UL Listed Product compliance: No Data Ow n o i EcoFasten® Rack For Installers By Installers ROCKIT COUPLING The fast Installing Rocklt Coupling -0//11m- easily attaches to the module frame to bridge the gaps between modules. —--- .._._---^'".-.-^ 1,4 SKIRT The sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically- pleasing finishing touch. vs ;'`r ROCKIT MOUNT Featuring integrated bonding pins,the Rocklt Mount connects to the Slide and can easily be ROCK positioned for fast installation. Features top _ - s down leveling. A COMPLETE RAIL-LESS RACKING SYSTEM The Rocklt system is the industry's premier rail-less PV racking system for composition shingle,tile,and Pi - metal roofs. Designed in conjunction with the needs of Composition Shingle, installers, Rocklt quickly&easily installs with a single tool. illiArue,Metal ROOF TYPE Featuring an easy-to-position alignment slide and a top- - down leveling system, Rocklt is logistically intelligent with no need to ship or transport long rails. Components are .... :::: Rail-Less available in a black finish that complements both commercial „ and residential applications.Conforms to UL 2703. RACKING FEATURES & BENEFITS 445k Structural-Attach • Patented watertight technology Direct-Attach ; t • Fullyintegrated bondingR IUIEN TACT � g • Top-down leveling system ROCKIT COMP SLIDE ` . • North-South adjustability ♦ ,-,�- Available in four variations,the Rocklt _ • Single tool install , .1 f Slide allows installation on composition • Florida Product Approved for composition shingle roofs . G HT'. - � shin le,tile,and metal roofs. 25YEARWARRANTY g FRAME MLPE MOUNT . ,=TECNNO LO uV�`:` STREAMLINED INSTALLATION WITH % Attaches and fully bonds MLPE's(Module MINIMAL ROOF PENETRATIONS v Level Power Electronics)to the module frame 1111111.4 with a single bolt clip. �j ECOFASTENSOLAR.COM PRODUCT CUT SHEET 454EcoFasten. PRODUCT CUT SHEET 1EcoFasten. For Installers. By Installers. For Insta LLc rs. By Installers. RI :AMP SLIDE AL BLK RI COMP SLIDE AL BLK PART NUMBER DESCRIPTION 2011013 RI COMP SLIDE AL BLK O 2) LAG SCREW, 5/16-4", THREAD 3", EPDM BACKED WASHER 00.75 5/16" THD 1 fp Head 0.34 y 3.87 c —4- i t . Material Stainless Steel Finish Mill ITEM NO. DESCRIPTION 1 ROCKIT V3 SLIDECOMP 2 LAG SCREW, 5/16-4",THREAD 3", EPDM BACKED WASHER 1) ROCKIT V3 SLIDECOMP 1111 4.0 0.38 S 0.03 1I.5 1 1.75 2.0--, Material Aluminum Finish Black REV.- CS1 REV.- CS1 PRODUCT CUT SHEET _4)4;5EcoFasten. For Installers. By Installers. GF-1 FLASHING GLV BLK 8X10" PART NUMBER DESCRIPTION 3012020 GF-1 FLASHING GLV BLK 8X10" 0 9 ITEM NO. DESCRIPTION 1 GF1 M-GAL-BLK-810 W/O WASHER ASSEMBLY 1) GF1 M-GAL-BLK-810 W/O WASHER ASSEMBLY 8.0 - 10.0 00.3 THRU e.: 1 0.31 0.02 Material Corrosion Resistant Steel Finish Black REV.- CS1 / S PZ structural ENGINEERS May 16,2022 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL:(877)859-3947 Attn.:Eco Fasten Solar LLC-Engineering Department Re:Report#2015-05884HG.07.01—EcoFasten-Rocklt System for Gable and Hip Roofs Subject:Engineering Certification for the State of Oregon PZSE, Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten-Rocklt System,as presented in PZSE Report#2015-05884HG.07.01,"Engineering Certification for the EcoFasten-Rocklt System for Gable and Hip Roofs". All information,data,and analysis therein are based on,and comply with,the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures,by American Society of Civil Engineers 2. 2019 Oregon Structural Specialty Code based on 2018 International Building Code 3. 2018 International Residential Code 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV)Panels,November 1,2012 by ICC-ES 5. Aluminum Design Manual 2018, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2018, National Design Specification for Wood Construction,by the American Wood Council Design Criteria: Risk Category II Seismic Design Category=A-E Exposure Category=B,C& D Basic Wind Speed(ultimate)per ASCE 7-16=90 mph to 180 mph Ground Snow Load=0 to 60(psf) DIGITALLY SIGNED This letter certifies that the loading criteria and design basis for the EcoFasten-Rocklt System Span Tables are . Np G%NEFP SP in compliance with the above codes. 85763 y If you have any questions on the above,do not hesitate to call. •REGON NOS 8,20' Prepared by: 96t K. ZAG�- PZSE, Inc.—Structural Engineers EXPIRES: 06>30n024 Roseville,CA 1478 Stone Point Drive, Suite 190, Roseville,CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience �iecni� i Ernpcv er, erri