Plans (2) LIABIL.BT°e _
i 1 _ Cite Tigare wr
r'
-11,- shaft .. -I---
i _l General Notes
II H �\ I v 1. Verify all dimensions and conditions, contact designer if they vary from these drawings. C a
N I' _ 1 2. All framing members to be Douglas Fir-Larch # 2, unless noted otherwise.
_ _ r I 3. All wood framing members in direct contact with concrete to be pressure treated.
, m I TO I 4. Framing connectors shall have all the nail holes filled as specified by the manufacturer, t,
unless noted otherwise. o
I CO ( 5. All new and replaced components of the building envelope shall be installed with proper ��
(/) ', drainage and flashing per Manufacturers' current written instructions and details as required^CI�C®
N by ORSC Section R703. RECE G
MAR 2 9 2023
Area of Work. CITY OF TIGARD
Description of Work BUILDING DIVISION
1. Property at 11301 SW Buffalo Place. ID# 1S134DA08500. ACCT# R2078128. LOT# 18.
,\ 2. Repair water damaged exterior deck privacy wall framing and sheathing. This wall located at L
11301 SW northwest corner of residential unit, does not provide separation from adjacent unit. .co
-
cc
Buffalo PI. ro I 3. Replace wall cap flashing.
Ia \ Approved pint-
— shall be on job site.
I 11311 Building Code Summary E
ea
- - — - Ar m 1 . 2021 Oregon Residential Specialty Code. 0
5 11321 2. Repairs per 2021 ORSC R102.7.2. 13.
cc 1 3. Type V Construction. OFFICE COPY
N CD
11340 uco
_ _ _ _ _ _ Contractor Drawings List c
•11350 Pure Environmental A1.0 Site Plan Ti o `"
Cl) 8206 N Fessenden Street, A1.1 Floor Plan �o ti
_ -rp — - - - Portland, Oregon 97203 A1.2 Privacy Wall Repair Detail 03 t
(503) 569-8425 CITY OF TIGAID N m
CCB# 229863 o
REVIEWED F(?[j�GDi: COMPLIANCE r' �
Contact: Andy Eberly .// M o a
Arprovcd: [ ] 0)
1 andy@purenvironmental.com OiC: [ 1 qq�� T- 7- l-
e GIP J VALIDITY OF PERMIT Permit It: 1' '7��2- D 1 ei Date
THE ISSUANCE OF A PERMIT 1
BASED ON CONSTRUCTION Address: n'Jp I 5� t(2-� 1, t 3/24/2023
N DOCUMENTS AND OTHER Suite #: General Notes
1 Site Plan y_. ' and Site Plan
DATA SHALL NOT PREVENT B � Date• `L�l�i3
CI THE CODE OFFICIAL FROM
A1.0 11" = 30' REQUIRING THE CORRECT'ON A1 .0
OF ERRORS. ORSC 105.4
0 -
Area of Work. / 5'-4"
Water damaged o
privacy wall. o
N i �
�} L 182
7
3 11301 SW Buffalo Place. �-
Repair Detail. 1
A1.2 �, _ ID# 1 S 134DA08500. 6.
r o ACCT# R2078128. E.'
(e) Unenclosed exterior t LOT# 18.
area under deck.
L
03
a.
0 11311 SW Buffalo Place.
cc
-47 No Work This Permit.
co
E
(v
0
L
d
U
C.)
CtS
11321 SW Buffalo Place. To
o
No Work This Permit. o cNj
CO cr)
Y gC.) � m
CDd
0 �
N '- Cl) O
M o c`o
r T r
Date
c!5
3l2412023
1 Floor Plan Floor Plan
A1 .1 1/8" = 1'-0"
A1 .1
New 24 GA. metal coping cap slope min. 1:12, �
New P.T. wood coping, -}.—
New Hi-temp S.A.M. lapped over W.R.B., C
Existing 2x top plate. 4) 1
o
S.S. fastener w/ neoprene gasket , o �
r
at 12" o.c., each side. ome 0 C
• dg
p
Continuous 22 GA. cleat, 7 °
U
>
fasten at 8" o.c. 1 A Existing Privacy Wall.
Siding to match existing. kiwLL
! WRB per Manufacturer's details. = N
A % B 1 layer existing 5/8" gypsum board. If damaged, replace with new 5/8" DensGlass " ..,
Fireguard gypsum sheathing OR new 5/8" fire retardant treated plywood.
Existing 2x6 wood studs at 16" o.c., replace as needed. -
i1 layer existing 5/8" gypsum board. If damaged, replace with new 5/8" DensGlass
Fireguard gypsum sheathing OR new 5/8" fire retardant treated plywood.
B WRB per Manufacturer's details.
ISiding to match existing.
L
0 0 (e) Deck does not bear on privacy wall. .p.
0 �'
i . )(_.\
0ca
(e) Deck boards. cm
it
(e) P.T. deck joists. L
d
o
d
v
CZI
(e) P.T. Base plate with anchor, a
(e) Concrete stem wall with foundation. IC 0 m
ca
/ New drip flashing, lap under WRB. a N
i m cu °'
C
o
_le) Grade. f co O
M
CD
___ ? ___ ,
Date
�' 1 Exterior Privacy Wall Repair Detail
_� C 3/2412023
_.
A 2 ,1 u = 1'-0n Privacy Wall
Repair Detail
( I ( ( > ' ( ( ( __________
= 11 ) �= - ilit ' ii � � 11= A1 .2