Plans M EC2022 -01031
OFFICE CAPV
AFrFiv
SHOP DRAWING AND SUBMITTAL REVIEW NOV 0 2 2
® CONFORMS TO DESIGN CONCEPT CITY OF-IGA RD
❑ CONFORMS TO DESIGN CONCEPT EXCEPT AS NOTED BUILDING DIVISION
❑ NON-CONFORMING,REVISE AND RESUBMIT
❑ REVIEWED
THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE WITH THE VALIDITY OF PERMIT
DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE HATH THE
INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.ANY ACTION SHOWN IS SUBJECT THE ISSUANCE OFA PERMIT Ili
TO THE REQUIREMENTS OF THE PLANS,SPECIFICATIONS AND APPLICABLE CODES,ALL
OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR BASED ON CONSTRUCTION
QUALITY, DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB
SITE),FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, DOCUMENTS AND OTHER
COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND THE
SATISFACTORY PERFORMANCE OF THE WORK DATA SHALL NOT PREVENT
THE CODE OFFICIAL FROM
REQUIRING THE CORRECTION
P u A Y 26U OF ERRORS. OSSC 105.4
N u/u V- Au/ Date 11/01/2022 By RonT ,--I
•
PANDUIT TYP. FM
RAP
HANGER STRAP DUCT 1--I
FULL STAP 7
ATTACH FLEX
12 GA. 1/IRE TU
LAGS
■/ACOUSTICAL LAGS DUCT TO RIGID Tb STRUCTURE ►�J O
O o 0 0 0 0 0 o O o TO STRUCTURE ROUND W/TIE r<�1
�P SEISMIC/SWAY •� Lo
I I I I �(�' 45A EVERY 16' • 1--I
ATTACH
STRAP
DUCT TO GRILLE 'I"i�'
R/TIE IN CHANGE
ir IN �1
DIRECTION r, F7-
O— I I I I vv/
O
I ; I �.
o- _ -__-_-�__ __ __-__-__�__-_ _ , i _ _ _--_- __- -__�__- -___ 1B GA NN
HANGER STRAP W
I FULL CIRCUM.
I MANUAL VOLUME i O
TYP. DI'P'[JSER DAMPER O
0- - __-__-__ __-__-__ __-_ _ _-_i__�__-__ __ __-__-__i--
TYP. DUCE p� ^
i A DUCT HANGER DETAIL E
Q
O SCALE: N.T.S. Q O
f I_4 F'
o- - - - - - - - - F,
O
Q a a
AREA OF WORK LICE COPY W
CITY OF TTGARD.- rT, C) x
REVIE D FOR CODE COMPLIANCE
K �,
Approved' j z
NTS
SCALE:E: NTS OTC: I j ,�
Yom/
Address: LS'3So Cil c1; ` P/<ar W
Suite #:
13) _ Date; 1 La-% 1 b
CIoS CJI�o�`Z3 6�G
F
_) HEET tNDEX
tq
140 . 0 — COVER SHEET, LEGEND , DETAILS Cq Do
,, 11 . 0 — MECHANICAL HVAC PLANS z
MECHANICAL LEGEND A z
11
:)UCTWORK FITTINGS (DOUBLE/SINGLE LINE) AND CONTROLS ABBREVIATIONS cf)
.E UNE DUCTWORK SINGLE LINE DUCTWORK P.O.C. PONT OF CONNECTION ~�
.]a -Am —e —e SUPPLY AR ELBOW UP VTR VENT THRU ROOF
AFF ABOVE FINISHED FLOOR
RETURN AR ELBOW UP BDD BACKDRAFr DAMPER /W
BTU H THERMAL UNIT
OUTSIDE AP/EXHAUST ELBOW UP CRIM CUBIC
FEET
PER MINUTE
.:Iz :0 ^^_ I J^^ SUPPLY AIR ELBOW DOWN (D EXISTING
�{
.]� RETURN AIR ELBOW DOWN ESP EXTERNA-STADC PRESSURE p
OUTSIDE AR/EXHAUST ELBOW DOWN EXH EXHAUST AS
GPM GALLONS PER MINUTE w
._® -----w%, FLEXIBLE DUCT HP HORSEPOWER
_ RNING MA MAKE-UP AIR
-_�VA OU
SOUARE ELBOW MBH 1000 BTU PER HR w
MFR MANUFACTURER a �
E (PD NEW
fD RADIUS EL BOW OSA OUTSIDE AIR
ACOUSTICALLY LINED DUCT PSI POUNDS PER SQUARE INCH
= (SSS SHOWN ARE NET INSIDE) RA RETURN AIR w
®
SUPPLY ASA SUPPLY AR
R DIFFUSER (R) RELOCATE
L_I SUPPLY AS SDEWALL REGISTER (REM) REMOVE Z
+ REFERENCE o
RETURN AS CEILING REGISTT3ir,
e CONNECT TO EXISTING AT THIS PONT W
VERIFY LOCATION, SEE,AND CONXTI ON. C—) p„1
® EXHAUST AR CEILING REOIBTTER O SHEET NOTE Qy Q
OUTSIDE AIR VENTILATION COMPLIANCE SCHEDULE
® ROOF TOP EXHAUST FAN i SMAsNt1AeER _ ____ - PEOPLEOUTDOOR AREAOUTDOOR REQUIRED SYSTEM _ ZONE AIR -.__, z �,
ROOM OCCUPANT AIRFLOW RATE IN AIRFLOW RATE IN BREATHING ZONE OUTDOOR AIR DISTRIBUTION _ W W F
® — — -- - — -
CELNG MOUNTED Qi REwsIGN _HVAC_ OR _ AREA DENSITY BREATHING ZONE _BREATHING_ZONE OUTDOOR FLOW INTAKE FLOW__. EFFECTNENESS o a w
UNIT ZONE (SQ. FT.) OCC. / 1000 SQ. FT. (CFM/PERSON) CFM / SQ. FT. (CFM) �CFHi) (Configuration) NOTES w
L-1 20X10 DFR�I/REGIST6i MAW NUMBER (E)HP45 OPEN OFFICE 200 2310 0 0.0 0.06 138.6 138.60 1.00 COMPLIES
RETURN/EXHAUST AR soEWALL REGISTER 500 TOTAL - 2310 - - - 138.60 - C01111PUES
1— AND MANUAL VOLUME DAMPER NECK SUE CAD NO. 4616
�20Xto TOTAL 2310 TOTAL 138.60
--0M MD MOTOR®DAMPER 500 ---i--------- I -- PROJECT NO. 6339
_ - PROPRIETARY
CFM Per chapter 4 section 403 8 table 403.3.1.1 -
- FSD FRE3MOKEDAAPER -- - ---- -_,.. ... - -----_. -�--
of the 2019 Edition of the Oregon Mechanical Specialty code. _ _---- _ THESE DRAW1N�fj)j fPECIRC4VPNS ARE CONFIDENTIAL AND SHALL REMAIN SHEET NO.
�I) THERMOSTAT MOUNTED•48'AFF WITH UNIT - T --. .—
VAV-18 NOTED ir— - - ------ - -- - - — - --�-- - --- - -- THE SOLE PROPERTY OF PROTEMP ASSOCIATES, INC. THEY SHALL NOT BE
------ t___ REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED
NOT ALL SYMBOLS OR ABBREVIATIONS CONTAINED IN THIS LEGEND WILL APPEAR ON DRAWINGS. -- --- r ' °
IN ANY MANNER ON OTHER PROJECTS OR EXSTENTIONS TO THIS PROJECT M00
WITHOUT THE PRIOR WRITTEN CONSENT OF PROTEMP ASSOCIATES, INC. 1 OF 2
SHOP DRAWING AND SUBMITTAL REVIEW
® CONFORMS TO DESIGN CONCEPT
❑ CONFORMS TO DESIGN CONCEPT EXCEPT AS NOTED
❑ NON-CONFORMING,REVISE AND RESUBMIT
❑ REVIEWED
THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE HATH THE
DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE III
INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.ANY ACTION SHOWN IS SUBJECT
TO THE REQUIREMENTS OF THE PLANS,SPECIFICATIONS AND APPLICABLE CODES,ALL Y
OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR
QUALITY, DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB
SITE),FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION,
COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND THE
SATISFACTORY PERFORMANCE OF THE WORK
•
Date 11/01/2022 By Ron'T
I • d7
Lo
z
s
o �
/(8)
r i
a o
o o E-I
x 8
175 W W
� d
• • w OE4 x
/(8)
• I CC)
8 I8 �
OPEN 8110
200 - -
(R)HP- (E)HP-1
3-TON 3.5 TON A
(R) (8) • HP-15 8) •
• L1
c'l Do
LAI ($ I H i $) Do H i
T R)HP I OHP-1
5
(E)THERMOSTATS 10'Y�
• TO DANGL17 LD
• 175 1 A z
H
u��I1 v
8o
/(8) 8
H • I F7 • �4
CQ
I
_x
P.
10 10cli
o �
o Z
0 C,
c�z E,
I
Lo
w �
z
94 W
a a
a
CAD NO. 4616
PROPRIETARY PROJECT NO. 6339
1 HVAC-FLOOR PLAN THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN SHEET NO.
THE SOLE PROPERTY OF PROTEMP ASSOCIATES, INC. THEY SHALL NOT BE
1 /4"=l'—O" REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED m 1 00
IN ANY MANNER ON OTHER PROJECTS OR EXSTENTIONS TO THIS PROJECT
NORTH WITHOUT THE PRIOR WRITTEN CONSENT OF PROTEMP ASSOCIATES, INC. 2 OF 2