Loading...
Plans M EC2022 -01031 OFFICE CAPV AFrFiv SHOP DRAWING AND SUBMITTAL REVIEW NOV 0 2 2 ® CONFORMS TO DESIGN CONCEPT CITY OF-IGA RD ❑ CONFORMS TO DESIGN CONCEPT EXCEPT AS NOTED BUILDING DIVISION ❑ NON-CONFORMING,REVISE AND RESUBMIT ❑ REVIEWED THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE WITH THE VALIDITY OF PERMIT DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE HATH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.ANY ACTION SHOWN IS SUBJECT THE ISSUANCE OFA PERMIT Ili TO THE REQUIREMENTS OF THE PLANS,SPECIFICATIONS AND APPLICABLE CODES,ALL OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR BASED ON CONSTRUCTION QUALITY, DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE),FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, DOCUMENTS AND OTHER COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND THE SATISFACTORY PERFORMANCE OF THE WORK DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION P u A Y 26U OF ERRORS. OSSC 105.4 N u/u V- Au/ Date 11/01/2022 By RonT ,--I • PANDUIT TYP. FM RAP HANGER STRAP DUCT 1--I FULL STAP 7 ATTACH FLEX 12 GA. 1/IRE TU LAGS ■/ACOUSTICAL LAGS DUCT TO RIGID Tb STRUCTURE ►�J O O o 0 0 0 0 0 o O o TO STRUCTURE ROUND W/TIE r<�1 �P SEISMIC/SWAY •� Lo I I I I �(�' 45A EVERY 16' • 1--I ATTACH STRAP DUCT TO GRILLE 'I"i�' R/TIE IN CHANGE ir IN �1 DIRECTION r, F7- O— I I I I vv/ O I ; I �. o- _ -__-_-�__ __ __-__-__�__-_ _ , i _ _ _--_- __- -__�__- -___ 1B GA NN HANGER STRAP W I FULL CIRCUM. I MANUAL VOLUME i O TYP. DI'P'[JSER DAMPER O 0- - __-__-__ __-__-__ __-_ _ _-_i__�__-__ __ __-__-__i-- TYP. DUCE p� ^ i A DUCT HANGER DETAIL E Q O SCALE: N.T.S. Q O f I_4 F' o- - - - - - - - - F, O Q a a AREA OF WORK LICE COPY W CITY OF TTGARD.- rT, C) x REVIE D FOR CODE COMPLIANCE K �, Approved' j z NTS SCALE:E: NTS OTC: I j ,� Yom/ Address: LS'3So Cil c1; ` P/<ar W Suite #: 13) _ Date; 1 La-% 1 b CIoS CJI�o�`Z3 6�G F _) HEET tNDEX tq 140 . 0 — COVER SHEET, LEGEND , DETAILS Cq Do ,, 11 . 0 — MECHANICAL HVAC PLANS z MECHANICAL LEGEND A z 11 :)UCTWORK FITTINGS (DOUBLE/SINGLE LINE) AND CONTROLS ABBREVIATIONS cf) .E UNE DUCTWORK SINGLE LINE DUCTWORK P.O.C. PONT OF CONNECTION ~� .]a -Am —e —e SUPPLY AR ELBOW UP VTR VENT THRU ROOF AFF ABOVE FINISHED FLOOR RETURN AR ELBOW UP BDD BACKDRAFr DAMPER /W BTU H THERMAL UNIT OUTSIDE AP/EXHAUST ELBOW UP CRIM CUBIC FEET PER MINUTE .:Iz :0 ^^_ I J^^ SUPPLY AIR ELBOW DOWN (D EXISTING �{ .]� RETURN AIR ELBOW DOWN ESP EXTERNA-STADC PRESSURE p OUTSIDE AR/EXHAUST ELBOW DOWN EXH EXHAUST AS GPM GALLONS PER MINUTE w ._® -----w%, FLEXIBLE DUCT HP HORSEPOWER _ RNING MA MAKE-UP AIR -_�VA OU SOUARE ELBOW MBH 1000 BTU PER HR w MFR MANUFACTURER a � E (PD NEW fD RADIUS EL BOW OSA OUTSIDE AIR ACOUSTICALLY LINED DUCT PSI POUNDS PER SQUARE INCH = (SSS SHOWN ARE NET INSIDE) RA RETURN AIR w ® SUPPLY ASA SUPPLY AR R DIFFUSER (R) RELOCATE L_I SUPPLY AS SDEWALL REGISTER (REM) REMOVE Z + REFERENCE o RETURN AS CEILING REGISTT3ir, e CONNECT TO EXISTING AT THIS PONT W VERIFY LOCATION, SEE,AND CONXTI ON. C—) p„1 ® EXHAUST AR CEILING REOIBTTER O SHEET NOTE Qy Q OUTSIDE AIR VENTILATION COMPLIANCE SCHEDULE ® ROOF TOP EXHAUST FAN i SMAsNt1AeER _ ____ - PEOPLEOUTDOOR AREAOUTDOOR REQUIRED SYSTEM _ ZONE AIR -.__, z �, ROOM OCCUPANT AIRFLOW RATE IN AIRFLOW RATE IN BREATHING ZONE OUTDOOR AIR DISTRIBUTION _ W W F ® — — -- - — - CELNG MOUNTED Qi REwsIGN _HVAC_ OR _ AREA DENSITY BREATHING ZONE _BREATHING_ZONE OUTDOOR FLOW INTAKE FLOW__. EFFECTNENESS o a w UNIT ZONE (SQ. FT.) OCC. / 1000 SQ. FT. (CFM/PERSON) CFM / SQ. FT. (CFM) �CFHi) (Configuration) NOTES w L-1 20X10 DFR�I/REGIST6i MAW NUMBER (E)HP45 OPEN OFFICE 200 2310 0 0.0 0.06 138.6 138.60 1.00 COMPLIES RETURN/EXHAUST AR soEWALL REGISTER 500 TOTAL - 2310 - - - 138.60 - C01111PUES 1— AND MANUAL VOLUME DAMPER NECK SUE CAD NO. 4616 �20Xto TOTAL 2310 TOTAL 138.60 --0M MD MOTOR®DAMPER 500 ---i--------- I -- PROJECT NO. 6339 _ - PROPRIETARY CFM Per chapter 4 section 403 8 table 403.3.1.1 - - FSD FRE3MOKEDAAPER -- - ---- -_,.. ... - -----_. -�-- of the 2019 Edition of the Oregon Mechanical Specialty code. _ _---- _ THESE DRAW1N�fj)j fPECIRC4VPNS ARE CONFIDENTIAL AND SHALL REMAIN SHEET NO. �I) THERMOSTAT MOUNTED•48'AFF WITH UNIT - T --. .— VAV-18 NOTED ir— - - ------ - -- - - — - --�-- - --- - -- THE SOLE PROPERTY OF PROTEMP ASSOCIATES, INC. THEY SHALL NOT BE ------ t___ REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED NOT ALL SYMBOLS OR ABBREVIATIONS CONTAINED IN THIS LEGEND WILL APPEAR ON DRAWINGS. -- --- r ' ° IN ANY MANNER ON OTHER PROJECTS OR EXSTENTIONS TO THIS PROJECT M00 WITHOUT THE PRIOR WRITTEN CONSENT OF PROTEMP ASSOCIATES, INC. 1 OF 2 SHOP DRAWING AND SUBMITTAL REVIEW ® CONFORMS TO DESIGN CONCEPT ❑ CONFORMS TO DESIGN CONCEPT EXCEPT AS NOTED ❑ NON-CONFORMING,REVISE AND RESUBMIT ❑ REVIEWED THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE HATH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE III INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.ANY ACTION SHOWN IS SUBJECT TO THE REQUIREMENTS OF THE PLANS,SPECIFICATIONS AND APPLICABLE CODES,ALL Y OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR QUALITY, DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE),FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND THE SATISFACTORY PERFORMANCE OF THE WORK • Date 11/01/2022 By Ron'T I • d7 Lo z s o � /(8) r i a o o o E-I x 8 175 W W � d • • w OE­4 x /(8) • I CC) 8 I8 � OPEN 8110 200 - - (R)HP- (E)HP-1 3-TON 3.5 TON A (R) (8) • HP-15 8) • • L1 c'l Do LAI ($ I H i $) Do H i T R)HP I OHP-1 5 (E)THERMOSTATS 10'Y� • TO DANGL17 LD • 175 1 A z H u��I1 v 8o /(8) 8 H • I F7 • �4 CQ I _x P. 10 10cli o � o Z 0 C, c�z E, I Lo w � z 94 W a a a CAD NO. 4616 PROPRIETARY PROJECT NO. 6339 1 HVAC-FLOOR PLAN THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN SHEET NO. THE SOLE PROPERTY OF PROTEMP ASSOCIATES, INC. THEY SHALL NOT BE 1 /4"=l'—O" REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED m 1 00 IN ANY MANNER ON OTHER PROJECTS OR EXSTENTIONS TO THIS PROJECT NORTH WITHOUT THE PRIOR WRITTEN CONSENT OF PROTEMP ASSOCIATES, INC. 2 OF 2