Plans M EC2022 -01030 OFFICE COPY RECEIVED Nov j-- - 3 2022 SHOP DRAWING AND SUBMITTAL REVIEW ❑ CONFORMS TO DESIGN CONCEPT BUILDI D SION ❑ CONFORMS TO DESIGN CONCEPT EXCEPT AS NOTED I ❑ NON-CONFORMING, REVISE AND RESUBMIT ® REVIEWED III THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE WITH THE VALIDITY OF PERMIT DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE HATH THE THE ISSUANCE OF A PERMIT INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.ANY ACTION SHONM IS SUBJECT III TO THE REQUIREMENTS OF THE PLANS,SPECIFICATIONS AND APPLICABLE CODES,ALL BASED ON CONSTRUCTION IY� OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR QUALITY, DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB DOCUMENTS AND OTHER SITE),FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, DATA SHALL NOT,PREVENT COORDINATION OF THE WORK VRTH THAT OF ALL OTHER TRADES AND THE SATISFACTORY PERFORMANCE OF THE WORK THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC for A Date 11/02/2022 By RonT RF ASSOU"" IATES _ CO PANDUIT HANGER STRAP TYP. FLEX V FULL CIRCUM. DUCE ATTACH FLEX 12 GA. WIRE 12 GA. WIRE DUCT TO RIGID * ACOUSTICAL LAGS IT ^ ^ ^ ^ ^ ^ ^ ^ lr/ACOUSTICAL LAGS STRUCTURE O O IY IY Y Y Y Y 7 7 Y 7 TO STRUCTURE ROUND W/TIE ry STRAP SEISMIC/SWAY ATTACH I BRACING • DUCT TO GRILE 45• EVERY 18' � ^F-1 A/TIE STRAP OR CHANGE IN DIRECTION Cq o- W p 1� (E--- ---------F------- I-------- ---- ---- - - -- ----- ---------F--------- 18 GA. O ✓' ry HANGER STRAPFULL CIRCUM. F+I O--- ---- I - I ---- i - - - ------- MANUAL VOLUME O I I I I TYP. DIFFUSER TYP�ECTT' i I I I IA DUCT HANGER DETAIL Z Z SCALE: N.T.S. O O U E-1 OFFICE COPY H H w AREA OF WORK CITY OF TIGARDy W FOR CODE COMPLTANC$ O > Approved: ) KEYPLAN oT�: 1 W � C F SCALE: NTS � F-J 1- Permic Address: k�fro ��Pa„Cl ; s Ploy Suite#t _ / W Byt, DatC. x 1�1 00 CXR � p}� 01106123 by �� � 1_ HEET tND EX Q C 312 9 A0. 0 - COVER SHEET, LEGEND , DETAILS x 11 . 0 - MECHANICAL HVAC PLANS 6 I��I z 2 N w a MECHANICAL LEGEND A z DUCTWORK FITTINGS (DOUBLE/SINGLE LINE) AND CONTROLS ABBREVIATIONS _E: LIE DUCTWORK SINGLE LINE DUCTWORK P.O.C. PONT OF CONNECTION ~� SUPPLY AR ELBOW UP VTR VENT E FIN ROOF '''7-� AFF ABOVE FIND FLOOR __ A :�o --ij -4 RETURN AR B-BOW UP BDD BACKDRAFT DAMPER W --� OUTSIDE AR/EXHAUST ELBOW UP BTU BRITISH THERMAL UNT CFM CUBIC FEET PER MINI -'� SUPPLY AR ELBOW DOWN (O E,(]STgtG OUTSIDE AIR (VENTILATION)COMPLIANCE SCHEDULE RETURN,SEL OW DOWN ESP EXTERNAL STATIC:PFF98FE PEOPLE OUTDOOR AREA OUTDOOR REQUIRED SYSTEM ZONE AIR o EXH EXHAUST AS ROOM OCCUPANT AIRFLOW RATE IN AIRFLOW RATE IN BREATHING ZONE OUTDOOR AIR DISTRIBUTION 00 GPM GALLONS PER MINUTE]/ ouTBDEAR/EXHAusrERJ3owDowN HVAC OR AREA DENSITY BREATHING ZONE BREATHING ZONE OUTDOOR FLOW INTAKE FLOW EFFECTIVENESS N w --- ____.. -gyp UNIT ZONE (SQ. FT.) OCC. / 1000 SQ. FT. (CFM/PERSON) CFM /SQ. FT. (CFM) (CFM) (Configuration) NOTES -allUlUlt! r""�' DST MA MAII, HP-8 OFFICE 206 119 5 5.0 0.06 10.115 10.12 1.00 COMPLIES _ VTURNM 80UARE ELBOW MBH loon BTU PER HOUR OFFICE 204 119 5 5.0 0.06 10.115 10.12 1.00 COMPLIES W MFR MANUFACTURER OFFICE 208 119 5 5.0 0.06 10.115 10.12 1.00 COMPLIES P. TD RADIUS ELBOW (N) NEW OFFICE 209 119 5 5.0 0.06 10.115 10.12 1.00 COMPLIES C\2 °BA OUTSIDE AIR COPY/FILES 214 195 4 5.0 0.06 15.6 15.60 1.00 COMPLIES O M ACOUSTICALLY LN®DUCT PSI PoIRUS PER SQUARE NCH BREAK 215 169 70 7.5 0.18 119.145 119.15 1.00 COMPLIES w (SIZES SHOWN ARE NET NSDE) RA RETURN AR �� c COMPLIES O w SA SUPPLY AS TOTAL - 840 - - - 175.23 E� _ 7) HP-13 HALL 203 119 0 0.0 0.06 7.14 7.14 1.00 COMPLIES SUPPLY AS Dill 7) RELOCATE �' U SUPPLY AS�Wy REGIIS EFl (REM) REMOVEHALL 210 154 0 0.0 0.06 9.24 9.24 1.00 COMPLIES 0 � Z � T REFERENCE OFFICE 211 282 5 5.0 0.06 23.97 23.97 1.00 COMPLIES o RETttRNAIR CIELNGREGISTER OFFICE 212 150 5 5.0 0.06 12.75 12.75 1.00 COMPLIES 1n E" e V�LOCATION,�AAIDCq�IION OFFICE 213 150 5 5.0 0.06 12.75 12.75 1.00 COMPLIES �z- a ® O 5 - COMPLIES O EXHAUST AS cERLNG REOlSTt3R L SHEET NOTE TOTAL 855 - - - - 65.8 t� ® ROOF TOP EXHAUST FAN EoRK ITMANRael� HP-14 RECEPTION 200 397 30 5.0 0.06 83.37 83.37 1.00 COMPLIES z � L SEE SCHEDULES CONFERENCE 201 274 50 5.0 0.06 84.94 84.94 1.00 COMPLIES ® CEILING MOUNTED EXHAUST FAN Q REVISION TOTAL 671 - - - - 168.31 - COMPLIES a a " a 20X10 p�p�/REGISTER MARK NUM6E3R HP-19 OFFICE 202 136 5 5.0 0.06 11.56 11.56 1.00 COMPLIES L� RENRN/EXHAUST ASMEWALLREOISTER 500 HALL203 223 5 5.0 0.06 18.955 18.96 1.00 COMPLIES �- MVD MANUAL VOLUME DAMPER NECK sqE �� OFFICE 204 130 5 5.0 0.06 11.05 11.05 1.00 COMPLIES CAD NO. 4615 OFFICE 205 282 5 5.0 0.06 23.97 23.97 1.00 1 COMPLIES -�M MD MOTOR®DAMPER 500 500 TOTAL - 771 - - - - 65.54 - COMPPROPRIETARY PROJECT NO. 6340 -� FSD FRE SMOKE DAMPER _ THEMAOSTAT MOUNTED•ae'AFF WITH UNIT TOTAL 3137 TOTAL 474.93 - THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN SHEET NO. VAV-t 9 NOTED --- THE SOLE PROPERTY OF PROTEMP ASSOCIATES, INC. THEY SHALL NOT BE o Per chapter 4, section 403 8 tattle 403.3.1.1m 0 of the zo19 Edition of the Oregon Mechanical specialty code. I NOT ALL SYMBOLS OR ABBREVIATIONS CONTAINED IN THIS LEGEND WILL APPEAR ON DRAWINGS. --' REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED I 0 IN ANY MANNER ON OTHER PROJECTS OR EXSTENTIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF PROTEMP ASSOCIATES, INC. 1 of 2 SHOP DRAWING AND SUBMITTAL REVIEW ❑ CONFORMS TO DESIGN CONCEPT ❑ CONFORMS TO DESIGN CONCEPT EXCEPT AS NOTED ❑ NON-CONFORMING,REVISE AND RESUBMIT ® REVIEWED THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITHTHE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.ANY ACTION SHOWN IS SUBJECT TO THE REQUIREMENTS OF THE PLANS,SPECIFICATIONS AND APPLICABLE CODES,ALL OF WHICH HAVE PRIORITY OVER THIS SUBMITTAL. CONTRACTOR IS RESPONSIBLE FOR QUALITY, DIMENSIONS(WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE),FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND THE SATISFACTORY PERFORMANCE OF THE WORK rl Date 11/02/2022 By RonT V � ' z - DN z c CIO) E Ln 4x24-B REP Z C\2 O VIL, 1/1 '0 8 O EXHA' ST 200 - - 0-4 250 V 1 0CXR A OFFICE H ® - dj z Z z 213 8 H 200 O O O 200 ® W � a -- - �-1z w /80 14"0 14" • • • 10'90 • iii �"' W 10" • g 200 (G�s )) 200 OE H 8 OPY Z 250 FFIC FILE CO FERE CE 10 O 212 14"iPl 214 201 �� W RE EPTI N x � 10"0 12"0 HALL 200 ^ 00 12"0 10 W -1 210 12"0 _EZ I RX 8 • 8 8 8 200 200 200 200 FFIC 0 209 FFIC FFIC OFFICE14 8 __ 208 207 206 200 16"0cq 12"0 T 10 0 14"0 _ � m OFFICE P- 0 2- ON C c - x 8 211 " I I o 250 „ HALL 8 203 8 A A z 200 80 200 8 250 - E I � � __L___ � U __ I 80 8� 8 OFFICEH -19 OFFICE 300 205 12 T 3 TON 204OFFICE 121. HP-1 12„0 10 0 202 0 -- 77 L41 11 o 8 8 26q 200 � x 8 300 ! IJ L 0 cr 04 L) o � cn 0 Z � E W z o A � Od CAD NO. 4615 PROPRIETARY PROJECT NO. 6340 1 HVAC-FLOOR PLAN THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN SHEET NO. THE SOLE PROPERTY OF PROTEMP ASSOCIATES, INC. THEY SHALL NOT BE o 1 /4"=l '—O” \ REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED m 1 0 IN ANY MANNER ON OTHER PROJECTS OR EXSTENTIONS TO THIS PROJECT NORTH WITHOUT THE PRIOR WRITTEN CONSENT OF PROTEMP ASSOCIATES, INC. 2 OF 2