Report Is the construction
material wood and does Yes
Type of the construction qualify If"Yes", qualifies for
Construction as "conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ❑ Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
x❑ Yes the prescriptive path.
❑ No
Is the combined weight X❑ Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes
If"Yes", qualifies for
with Section 305.4(3)of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑x of composition
shingle.
Is the roof mounted x❑ Yes
Connections of solar assembly
If"Yes", qualifies for
the solar assembly connected to roof ❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
1.BuildinglForms/PhotoVoltaic-Checklist02-01-11.docx
Document Ref AACTF-UTOSI-UCEDW-NCJYG 1 %" +
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam
prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 'Y2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members E No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof El Yes the prescriptive path.
surface. ❑ No
3
1:1Building.Fonnsi 1'hotoVolta is-Check list02-01-11.docx
Document Ref:AACTF-UTQSI-UCEDW-NCJYG Page 7 of 8
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAe
Model Number: SIL-380 HC
Listing Agency:
4
I:/Bui Iding/Fonns/PhotoVoltaic-Check fist02-01-11.docx
Document Ref:AACTF-UTQSI-UCEDW-NCJYG 71, Page 8 of 8
';•iii'ii'i nt •ti'••••:NiWt,iK •i••.i�'ii'K•.:-.'ii'i•r:*;Niiti'i:iiieiiiiiii'iiiii'i-.K.ii'•'iiii••iii'ii'i,4"iii%i�i�i iii : i
i•Mi' i•'••::
�1•: ::.,•:
Signature Certificate
`a Reference number AACTF-UTQSI-UCEDW-NCJYG •�•'•
�••.'' Signer Timestam Signature - - �•�
'•••' Dustin Davidson °:''
�.y, Email:dustin.davidson@ionsolar.com }��.;
�
}�•1 Sent: 22 Dec 2022 18:01:38 UTC :::".1.:•
:
♦�%; •
Signed: 22 Dec 2022 18:01:38 UTC t.. ::::•
'NY
IP address:66.219.246.14 y•.j
N Location:Provo,United States i':
:M' •i:�
..., l..
j•;; Document completed by all parties on: :♦ii':
}:•:♦; 22 Dec 2022 18:01:38 UTC ••••;�
At;
P:; ::':
::. Page 1 of 1 'ele:
:•:• .•Da
• ...
;•.. :•1.'•:.
❖: .. :,
.y.. ..�•••..
;... :0.•.
.1'1 :i'J.
ti•••: `.,
:0•: t••4
•.•
'i :
.i••
�:' .1••�
♦••••' •1.•%.
••••: .•N.•
4..• �••
♦:�.:. 1.•r.
•.' V..
i�:: .::.
:•.i' too.
...to ..
oo .�
, •
4••
i':: :4:.
H ♦♦
4%l, 4ow
..
H •N
••• 4 •
v.' •❖.
'.•:: .•.'..
W. Signed with PandaDoc •0 •
�.�.�.
;.�y. Pd PandaDoc is a document workflow and certified eSignature ,i'1 4. +:
����, solution trusted by 30,000+companies worldwide. t •u- .�.•i;.
i•.'. .A0.4.
••.::::::O::PLO i i "�i i•*•.i00:O.O•pi•1•'�Y•�•i4•i i'i i i i�l•.Y • •i i •i i i i`i i i ii i:Oii i'•••••::O:?i.� :.`.�:ii•:Ii.
�i •�� �:4L•. •:�.�4�� i%!�.��•!�•%� i•i•i%. � �•i4 %i Q• !i!i4 i !�.;.:.�•S '!!!� !!�Q�•�.i�i i•i i i� •d i �.