2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
Photo Voltaic Solar Panel System
Property Information
Installation Address: 16264 SW 104th Ave
City: Tigard Zip: 97224
Owner's Name: Nixon Lange Date: 12-15-2022
Contractor's Name: ION Developer LLC CCB #: 230394
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? x❑ No OSSC or ORSC for
design requirements.
El
Is the wind exposure Yes If"Yes", qualifies for
Wind Exposure "C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes",qualifies for
family townhomes ❑x Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
El
"Yes", qualifies for
structures other than
Yes the prescriptive path.
above
❑ No
1
1:Building/Forms/Photovoltaic-Checklist02-01-11.docx
Document Ref:XQ8LB-83VTD-ZHC7E-IHAII Page 5 of 8
•
Is the construction
material wood and does 0 Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as"conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ❑ Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. x❑ Yes the prescriptive path.
❑ No
Is the combined weight X❑ Yes
of the PV modules and If"Yes", qualifies for
racking less than or No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance 0 Yes
with Section 305.4(3)of If"Yes", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑x of composition
shingle.
Is the roof mounted n Yes
Connections of solar assembly
If"Yes", qualifies for
the solar assembly connected to roof ❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
1:/Building/Forms/PhotoV oltaic-Checklist02-01-11.docx
Document Ref:XQ8LB-83VTD-ZHC7E-IHAII
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam
prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of ❑ Yes If"Yes", qualifies for
fastener? the prescriptive path.
❑ No
Is the roof decking of
WSP min. %"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof El Yes the prescriptive path.
surface. ❑ No
3
I:%Building/Forms,'PhotoV oltaic-Checklist02-01-11.docx
Document Ref;XQSLB-83VTD-ZHC7E-IHAII >��. .`"DST0424
•
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: sip-380 HC
Listing Agency:
4
1./Building.Forms/PhotoVoltaic-Checklist02-01-11.docx
Document Ref.XQ8LB-83VTD-ZHC7E-IHAII 5 Page 8 of 8
iii'?ii• ii iii ii�ii0 iiiiiX iitii ::i•:•i:tiii i ii:•: i••.,ii JP7tii Ji�iiii:ti :J:':•iiiiii•:ii•:•lti•:•iiii : {:
•••• !•!•!"!.44•!:l.4•15:44411 !!!-1 ::!vM41!:!!44.1t!vi!-'5!V!:! :4!.!ordr•tv!"1!-M:!:t�❖••i•••�i••Q•s s•4Qi••�•Vi�•1•.•4••••••%.%ate!V•V
w.
Signature CertificateVW
•.o••
•Reference number:XQ8LB-83VTD-ZHC7E-IHAII y❖:•.
"Alt.. :•r•
:Y Signer Timestamp Signature ;•:;•
Me:, .Dustin Davidson r••,
..4....
:4ti Email:dustin.davidson@ionsolar.com :$
/��/// Jam/ ye :
j:�V Sent 15 Dec 2022 18:45:32 UTC :••:•
;..V, Signed: 15 Dec 2022 18:45:32 UTC „ ,..,. ... +:;•
•••. IP address:66,215,246.14 0.
•;.•W •
Location:Provo,United States .•ii�.
•r
4'; Document completed by all parties on: i•❖'
P•:': 15 Dec 2022 18:45:32 UTC v• '
V: Page 1 of 1 444'
•.. :•.
AN
••, •ii++...V
M.: .•+•.
•,. 0..
An 4.4 ':•:%
•••i :::
••: +4.:
H• •0%
•••••' :4::.
,h•; t•H
••• .......
L••: ..v.
!•::. +,r
i•:. •••l
�••• %••i'
•+•:: ,�i
•:i i•:.
:+/: '::.
♦1 :•r
:•. •+..
:::: AN.
::: Signed with PandaDoc 440 •'::'.
':•: 0 PandaDoc is a document workflow and certified eSignature r r' �r. %.;
:Y solution trusted by 30,000+companies worldwide. I 'CI ;�•
+•• ❑ • r•
At 'A:'
A ••:❖.
+•. :•.
pg.,
�:�•'i:�i:�i:•i i4�i':•:•i:':•�•:•i:•i�i:i�i•-•�i iiti�i�:•��i Oii�:iiiii:•iii-:•iiiiiiii�:G•i:•i0•i::•i._ii i�i-i•:•�•�i'.•::