Permit Support Document COMcheck Software Version COMcheckWeb init 11 Mechanical Compliance Certificate Project Information 4 Y ►'C , Energy Code: 90.1 (2019) Standard 9 ,; Project Title: Safeway Tigard # 1478 TI Location: Tigard, Oregon :VfY'OF.1iGArit) K Climate Zone: 4c M DING DF''Pr9ON Project Type: Addition / c2o/2- 0i137 Construction Site: Owner/Agent: Designer/Contractor: 15570 SW Pacific Hwy Oregon Louis Leon Tigard,Oregon 97224 Protemp Associates Inc 9788 SE 17th Ave Portland, Oregon 97222 5035193083 louis@protmp.com Mechanical Systems List QuantitySystem Type & Description 1 HVAC System (Single Zone): Split System Heat Pump Heating Mode: Capacity= 22 kBtu/h, ��� Proposed Efficiency= 11.80 HSPF, Required Efficiency=8.20 HSPF �,�� Cooling Mode: Capacity= 22 kBtu/h, OF Proposed Efficiency= 20.00 SEER, Required Efficiency= 14.00 SEER Proposed Part Load Efficiency=0.00 , Required Part Load Efficiency=0.00 Fan System: FAN SYSTEM 1--Compliance(Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 1 Supply. Single-Zone VAV, 2235 CFM, 1.5 motor nameplate hp, 1.00 fan energy index Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 90.1 (2019) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. ZIP ‘717 _J-,,,, .>"" ......---- /___4.4L____ a e-Title Signature Date Project Title: Safeway Tigard # 1478 TI Report date: 12/06/22 Data filename: Page 1 of 9 ritCOMcheck Software Version COMcheckWeb If Inspection Checklist Energy Code: 90.1 (2019) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 6.4.4.2.1, calculations provide all information ❑Does Not 6.7.2 ,with which compliance can be [PR2]1 determined for the mechanical DNot Observable systems and equipment and ❑Not Applicable i document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. 4.2.2, Plans, specifications,and/or ❑Complies ' 8.4.1.1, calculations provide all information '❑Does Not 8.4.1.2, with which compliance can be 8.7 determined for the electrical systems :❑Not Observable [PR6]2 and equipment and document where :❑Not Applicable exceptions are claimed.Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. 4.2.5.2 Commissioning shall be performed as ❑Complies Requirement will be met. (PR5]1 stated in Sections 5.9.2,6.9.2,7.9.2, ;❑Does Not 8.9.2, 9.9.2, 10.9.2, 11.2(d),and G1.2.1(c).Commissioning must utilize ❑Not Observable ASHRAE/IES Standard 202 or other Observable_ Applicable generally accepted engineering standards acceptable to the building official. FPT and verification requirements for commissioning are as stated in Section 4.2.5.1. Commissioning shall document compliance of the building systems, controls, and building envelope with required provisions of this standard. Commissioning requirements shall be incorporated into the construction documents. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Safeway Tigard # 1478 TI Report date: 12/06/22 Data filename: Page 2 of 9 Section Mechanical Rough-In I Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions & Req,ID 6.4.1.4, HVAC equipment efficiency Efficiency:_ Efficiency: ;❑Complies See the Mechanical Systems list 6.4.1.5 verified. Non-NAECA HVAC j❑Does Not for values. [ME1]2 equipment labeled as meeting 90.1. :❑Not Observable I ❑Not Applicable 6.4.3.4.1 Stair and elevator shaft vents ❑Complies Exception: Requirement [ME3]3 have motorized dampers that ❑Does Not does not apply. automatically close. ❑Not Observable I ❑Not Applicable : 6.4.3.4.2, Outdoor air and exhaust systems ❑Complies I Requirement will be met. 6.4.3.4.3 have motorized dampers that ❑Does Not [ME4]3 automatically shut when not in use and meet maximum leakage ❑Not Observable rates. Check gravity dampers ❑Not Applicable where allowed. 6.4.3.4.5 Enclosed parking garage ❑Complies Exception: Requirement [ME39]3 ventilation has automatic ❑Does Not does not apply. contaminant detection and capacity to stage or modulate [Not Observable fans to 50%or less of design ❑Not Applicable j capacity. 6.4.3.4.4 Ventilation fans>0.75 hp have ❑Complies Requirement will be met. [ME5]3 automatic controls to shut off fan ❑Does Not when not required. g? ❑Not Observable ❑Not Applicable 6.4.3.8 Demand control ventilation ❑Complies ;Requirement will be met. [ME6]1 provided for spaces >500 ft2 and ❑Does Not >25 people/1000 ft2 occupant density and served by systems Not Observable with air side economizer, auto ❑Not Applicable ;modulating outside air damper ;control, or design airflow>3,000 :ivc -.,s I ]cfm. 6.5.3.2.1 DX cooling systems>= 75 kBtu/h ❑Complies ;Requirement will be met. [ME40]2 (>= 65 kBtu/h effective 1/2016) ❑Does Not and chilled-water and See the Mechanical Systems list evaporative cooling fan motor hp ❑Not Observable 'for values. >= 1/4 designed to vary supply ❑Not Applicable fan airflow as a function of load , and comply with operational requirements. 6.4.4.1.1 Insulation exposed to weather ❑Complies Requirement will be met. [ME7]3 protected from damage. ❑Does Not Insulation outside of the conditioned space and associated ['Not Observable with cooling systems is vapor ❑Not Applicable retardant. , 6.4.4.1.2 HVAC ducts and plenums ; R- R-_ OComplies Requirement will be met. [ME8]V insulated per Table 6.8.2.Where ❑Does Not ducts or plenums are installed in : or under a slab,verification may ❑Not Observable need to occur during Foundation ❑Not Applicable Inspection. 6.4.4.1.3 HVAC piping insulation thickness. : _in. _in. ;❑Complies Requirement will be met. [ME9]2 Where piping is installed in or ❑Does Not under a slab,verification may need to occur during Foundation ['Not Observable Inspection. ❑Not Applicable 6.4.4.1.4 Thermally ineffective panel ❑Complies Requirement will be met. [ME41]3 surfaces of sensible heating ❑Does Not panels have insulation>= R-3.5. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Safeway Tigard # 1478 TI Report date: 12/06/22 Data filename: Page 4 of 9 Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions & Req.ID 6.4.4.2.1 :Ducts and plenums having ❑Complies Exception: Requirement [ME10]2 pressure class ratings are Seal ❑Does Not does not apply. Class A construction. ❑Not Observable DNot Applicable 6.8.1-15, Electrically operated DX-DOAS ❑Complies ,Exception: Requirement 6.8.1-16 units meet requirements per ❑Does Not does not apply. [ME110]2 Tables 6.8.1-15 or 6.8.1-16. DNot Observable DNot Applicable 6.4.4.2.2 Ductwork operating >3 in.water ❑Complies Requirement will be met. [ME11]3 column requires air leakage ❑Does Not testing. ❑Not Observable DNot Applicable 6.5.2.3 !Dehumidification controls ❑Complies Requirement will be met. [ME19]3 provided to prevent reheating, ❑Does Not recooling,mixing of hot and cold airstreams or concurrent heating ['Not Observable and cooling of the same ONot Applicable airstream. 6.5.2.4.1 Humidifiers with airstream ❑Complies ;Requirement will be met. [ME68]3 mounted preheating jackets have ❑Does Not preheat auto-shutoff value set to activate when humidification is ❑Not Observable not required. ❑Not Applicable 6.5.2.4.2 Humidification system dispersion ❑Complies Requirement will be met. [ME69]3 tube hot surfaces in the ❑Does Not airstreams of ducts or air- handling units insulated >= R- DNot Observable 0.5. ❑Not Applicable 6.5.2.5 Preheat coils controlled to stop ❑Complies Requirement will be met. [ME70]3 heat output whenever ❑Does Not mechanical cooling, including economizer operation, is active. ❑Not Observable ElNot Applicable 6.5.2.6 Units that provide ventilation air ❑Complies Requirement will be met. [ME106]3 to multiple zones and operate in ❑Does Not conjunction with zone heating and cooling systems are ❑Not Observable prevented from using heating or :Not Applicable heat recovery to warm supply air above 60°F when representative building loads or outdoor air temperature indicate that most zones demand cooling. 6.5.3.6 Motors for fans>= 1/12 hp and ❑Complies Requirement will be met. [ME72]2 < 1 hp are electronically- ❑Does Not commutated motors or have a minimum motor efficiency of ['Not Observable 70%.These motors are also ❑Nat Applicable speed adjustable for either balancing or remote control. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Safeway Tigard# 1478 TI Report date: 12/06/22 Data filename: Page 5 of 9 Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions & Req.ID 6.5.3.4 Parallel-flow fan-powered VAV air ❑Complies Requirement will be met. [ME108]2 terminals have automatic ❑Does Not controls to a)turn off the terminal fan except when space Not Observable heating is required or if required ElNot Applicable for ventilation; b)turn on the terminal fan as the first stage of heating before the heating coil is activated; and c)during heating for warmup or setback temperature control, either operate the terminal fan and heating coil without primary air or reverse the terminal damper logic and provide heating from the central air handler through primary air. 6.5.3.7 Required minimum outdoor air ❑Complies Requirement will be met. [ME109]2 rate is the larger of minimum ❑Does Not outdoor air rate or minimum exhaust air rate required by ['Not Observable Standard 62.1, Standard 170,or ❑Not Applicable applicable codes or accreditation standards.Outdoor air ventilation systems shall comply with one of the following: a)design minimum system outdoor air provided < 135%of the required minimum outdoor air rate, b) dampers, ductwork, and controls allow the system to supply<=the required minimum outdoor air rate with a single set-point adjustment., or c)system includes exhaust air energy recovery complying with Section 6.5.6.1. 6.5.3.3 Multiple zone VAV systems with ❑Complies Exception: Requirement [ME42]3 DDC of individual zone boxes ❑Does Not does not apply. have static pressure setpoint reset controls. ❑Not Observable See the Mechanical Systems list ❑Not Applicable for values. 6.5.4.2 HVAC pumping systems with >= ❑Complies Requirement will be met. [ME25]3 3 control values designed for ❑Does Not variable fluid flow(see section details). ENot Observable ❑Not Applicable 6.5.6.1.1 Exhaust Air Energy Recovery for ❑Complies Requirement will be met. [ME56]1 Nontransient Dwelling Units ❑Does Not ENot Observable ❑Not Applicable 6.5.6.1.2 Exhaust air energy recovery for ❑Complies Requirement will be met. [ME111]1 spaces other than Nontransient ❑Does Not ;dwelling units meeting Tables .6.5.6.1.2-1, and 6.5.6.1.2-2. ENot Observable ENot Applicable 6.5.7.2.1 Kitchen hoods>5,000 cfm have ❑Complies Exception: Requirement [ME32]2 make up air>=50%of exhaust ❑Does Not does not apply. air volume. ❑Not Observable i ENot Applicable 1 High Impact(Tier 1) j j Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Safeway Tigard# 1478 TI Report date: 12/06/22 Data filename: Page 6 of 9 Section Mechanical Rough-In Plans Verified Field Verified Complies? Comments/Assumptions & Req.ID Inspection Value Value 6.5.7.1 :Conditioned supply air to space ❑Complies Requirement will be met. [ME100]2 ;with mechanical exhaust<=the ❑Does Not greater of criteria of supply flow, required ventilation rate, exhaust ❑Not Observable flow minu the available transffer ❑Not Applicable air(see section details). 6.5.3.8 Occupied standy controls for ❑Complies Requirement will be met. [ME112]' zones serving rooms that are ❑Does Not required to have automatic partial OFF or automatic full OFF ['Not Observable lighting controls per Section ❑Not Applicable 9.4.1.1 shall meet the following within five minutes of all rooms in ;that zone entering occupied- standby mode: a)Active heating set point shall be setback at least 1°F, b)Active cooling set point shall be setup at least 1°F and c)All airflow supplied to the zone shall be shut off whenever the 'space temperature is between the active heating and cooling set points. 6.5.7.2.4 Approved field test used to ❑Complies Requirement will be met. [ME49]3 evaluate design air flow rates Does Not and demonstrate proper capture .and containment of kitchen ❑Not Observable exhaust systems. ❑Not Applicable 6.5.8.1 "'Unenclosed spaces that are ❑Complies Requirement will be met. [ME34]2 heated use only radiant heat. ElDoes Not ['Not Observable ElNot Applicable 6.4.3.9 Heating for vestibules and air ElComplies Requirement will be met. [ME63]2 curtains with integral heating ❑Does Not include automatic controls that shut off the heating system when ['Not Observable outdoor air temperatures>45F. ❑Not Applicable Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint<= 60F and cooling setpoint>=80F. 6.5.10 Doors separating conditioned ❑Complies Requirement will be met. [ME73]3 space from the outdoors have ❑Does Not controls that disable/reset heating and cooling system when ❑Not Observable open. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) :` ;4Medium Impact(Tier 2) j 3 Low Impact(Tier 3) Project Title: Safeway Tigard # 1478 TI Report date: 12/06/22 Data filename: Page 7 of 9 . Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 8.4.2 At least 50%of all 125 volt 15-and ❑Complies [EL10]2 20-Amp receptacles are controlled by ❑Does Not an automatic control device. ❑Not Observable ❑Not Applicable 8.4.3 New buildings have electrical energy '❑Complies [EL11]2 use measurement devices installed. ,ODoes Not Where tenant spaces exist, each [tenant is monitored separately. In ❑Not Observable buildings with a digital control system ❑Not Applicable the energy use is transmitted to to control system and displayed graphically. 10.4.1 Electric motors meet requirements .❑Complies Requirement will be met. [EL9]2 where applicable. ❑Does Not :Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) . Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Safeway Tigard # 1478 TI Report date: 12/06/22 Data filename: Page 8 of 9 Section # Final Inspection Complies? Comments/Assumptions & Req.ID 6.4.3.1.2 Thermostatic controls have a 5 °F I❑Complies Requirement will be met. (FI3j3 deadband. j❑Does Not i❑Not Observable I ❑Not Applicable 6.4.3.2 'Temperature controls have setpoint ,❑Complies Requirement will be met. [F12013 'overlap restrictions. ❑Does Not ❑Not Observable j❑Not Applicable 6.4.3.3.1 HVAC systems equipped with at least ❑Complies Requirement will be met. [F121]3 one automatic shutdown control. '❑Does Not ❑Not Observable ❑Not Applicable 6.4.3.3.2 ;Setback controls allow automatic I❑Complies Requirement will be met. [FI22j3 `restart and temporary operation as ❑Does Not required for maintenance. ❑Not Observable ❑Not Applicable 6.4.3.5 Heat pump controls prevent '❑Complies Requirement will be met. [F15]3 supplemental electric resistance heat iODoes Not from coming on when not needed. ❑Not Observable ❑Not Applicable 6.4.3.6 When humidification and ❑Complies Requirement will be met. [FI6]3 dehumidification are provided to a ❑Does Not zone, simultaneous operation is prohibited. Humidity control prohibits ONot Observable the use of fossil fuel or electricity to ❑Not Applicable produce RH > 30%in the warmest zone humidified and RH < 60%in the coldest zone dehumidified. 6.7.2.1 ,Furnished HVAC as-built drawings ❑Complies Requirement will be met. [FI713 submitted within 90 days of system ❑Does Not 'acceptance. :Not Observable ❑Not Applicable 6.7.2.2 'Furnished O&M manuals for HVAC ❑Complies Requirement will be met. [FI8]3 systems within 90 days of system ❑Does Not acceptance. ❑Not Observable' ❑Not Applicable !. 6.7.2.3 An air and/or hydronic system ❑Complies Requirement will be met. [FI9]1 balancing report is provided for HVAC ❑Does Not systems serving zones>5,000 ft2 of ❑Not Observable conditioned area. j❑Not Applicable 10.4.3 Elevators are designed with the ;❑Complies ,Exception: Requirement does not apply. [F12412 proper lighting, ventilation power, and ❑Does Not standby mode. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) .3''Low Impact(Tier 3) Project Title: Safeway Tigard# 1478 TI Report date: 12/06/22 Data filename: Page 9 of 9