Report (3) 1UP W 22 - 00017 OFFICE COPY
•
COMcheck Software Version 4.1.5.3
Interior Lighting Compliance Certificate
RECEIVED
Project Information APR 04 2022
Energy Code: 2018 IECC CI l r u- IIGARD
Project Title: AVA Mixed Use BUILDING DIVISION
Project Type: New Construction
-I Construction Site: Owner/Agent: Designer/Contractor:
$4 4.2.37 SW Main St Neek Engineering MFIA
Tigard, OR 4770 SW Hall Blvd 2007 SE Ash St
Beaverton, OR 97005 Portland, OR 97214
503-234-0548
Additional Efficiency Package(s)
Credits: 1.0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Future Retail Spaces(Retail:Sales Area) 5287 1.10 5816
2-Stairs(Common Space Types:Stairwell) 968 0.52 503
3-Equipment Rms(Common Space Types:Electrical/Mechanical) 670 0.39 261
4-Lobby(Common Space Types:Lobby-General) 277 0.90 249
5-Corridor(Common Space Types:Corridor/Transition<8 ft wide) 1925 0.59 1136
Total Allowed Watts= 7965
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description I Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
1-Future Retail Spaces(Retail:Sales Area)
LED 1:Al:4ft Gen Purp Strip: LED Panel 36W: 1 25 35 875
2-Stairs(Common Space Types:Stairwell)
LED 2:B1:4ft wraparound:LED Linear 22W: 1 14 25 350
3-Equipment Rms (Common Space Types:Electrical/Mechanical)
LED 3:Al:4ft Gen Purp Strip:LED Panel 36W: 1 9 35 315
LED 4:B1:4ft wraparound:LED Linear 22W: 1 2 25 50
4-Lobby(Common Space Types:Lobby- General)
LED 5:B2:8ft recessed strip:LED Linear 22W: 1 4 26 104
5-Corridor(Common Space Types:Corridor/Transition <8 ft wide)
LED 6:C1:4"downlight:LED PAR 16W: 1 54 16 864
Total Proposed Watts= 2558
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:\NEEK Engineering\10000_AVA Mixed Use 1Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 1 of 9
•
y �
PO**
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been
designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Denise Taylor, Elect. Designer Denise Taylor 03.22.2022
Name-Title Signature Date
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 2 of 9
COMcheck oft are Version .1.5.3
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2018 IECC
Project Title: AVA Mixed Use
Project Type: New Construction
Exterior Lighting Zone 2(Residential mixed use area(LZ2))
Construction Site: Owner/Agent: Designer/Contractor:
12537 SW Main St Neek Engineering MFIA
Tigard,OR 4770 SW Hall Blvd 2007 SE Ash St
Beaverton, OR 97005 Portland, OR 97214
503-234-0548
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/Unit Wattage (B X C)
Entry Canopies(Entry canopy) 1651 ft2 0.25 Yes 413
Parking areas(Parking area) 5214 ft2 0.04 Yes 209
Total Tradable Watts(a)= 621
Total Allowed Watts= 621
Total Allowed Supplemental Watts(b)= 400
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description/ Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Entry Canopies (Entry canopy 1651 ft2):Tradable Wattage
LED 1:Si: Ext.Chg.Light:LED PAR 11W: 1 6 11 66
LED 2:S2:4"downlight:LED PAR 16W: 1 9 16 144
LED 3:S3: Ext.Wall Sconce: LED A Lamp 25W: 1 12 22 264
LED 4:S4: Ext.wall Pack: LED A Lamp 25W: 1 3 24 72
Parking areas( Parking area 5214 ft2):Tradable Wattage
LED 5:S5:4ft Enclosed Strip:LED Panel 41W: 1 8 42 336
LED 6:S6:Pole Mnt Area Light: LED Roadway-Parking Unit 42W: 1 3 38 114
Total Tradable Proposed Watts= 996
xteruor Lighting PAS . ti 2% bet Cod
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been
designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:INEEK Engineering110000_AVA Mixed Use\Energy Forms110000 AVA Mixed Use-Lighting.cck Page 3 of 9
Denise Taylor, Elect. Designer Denise Taylor 03.22.2022
Name-Title Signature Date
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 4 of 9
COMcheck Software Version 4.1.5.3
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 69.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plan Review I Complies? Comments/Assumptions
& Req.ILl
C103.2 ;Plans, specifications, and/or IIMComP lies
[PR4]1 calculations provide all information ❑Does Not
with which compliance can be
;determined for the interior lighting ['Not Observable
land electrical systems and equipment ❑Not Applicable
;and document where exceptions to
;the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
:bulbs and ballasts,transformers and
:control devices.
C103.2 :Plans,specifications, and/or [Complies
[PR8]1 calculations provide all information ❑Does Not
;with which compliance can be
determined for the exterior lighting ['Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
C406 ,Plans, specifications, and/or ti(7Complies
[PR9]1 calculations provide all information ❑Does Not
;with which compliance can be
determined for the additional energy ['Not Observable
:efficiency package options. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 5 of 9
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.2. ;Spaces required to have light- /SCornplies
2 ;reduction controls have a manual ❑Does Not
[EL22]1 control that allows the occupant to
;reduce the connected lighting load in ❑Not Observable
a reasonably uniform illumination ❑Not Applicable
pattern >= 50 percent.
C405.2.1, ;Occupancy sensors installed in ❑Complies
C405.2.1. :classrooms/lecture/training rooms, ❑Does Not
1 conference/meeting/multipurpose
[EL18]1 ;rooms,copy/print rooms, ❑Not Observable
;lounges/breakrooms, enclosed offices, INotApplicable
;open plan office areas, restrooms,
;storage rooms, locker rooms,
warehouse storage areas, and other
;spaces <= 300 sqft that are enclosed
by floor-to-ceiling height partitions.
;Reference section language
C405.2.1.2 for control function in
;warehouses and section C405.2.1.3
;for open plan office spaces.
C405.2.1. Occupancy sensors control function in ❑Complies
2 warehouses: In warehouses, the ❑Does Not
[EL19]1 lighting in aisleways and open areas is
controlled with occupant sensors that ❑Not Observable
:automatically reduce lighting power ®Not Applicable
by 50%or more when the areas are
:unoccupied.The occupant sensors
:control lighting in each aisleway
:independently and do not control
lighting beyond the aisleway being
controlled by the sensor.
C405.2.1. Occupant sensor control function in ❑Complies
3 :open plan office areas: Occupant ❑Does Not
[EL20]1 sensor controls in open office spaces ❑Not Observable
I>= 300 sq.ft. have controls 1)
:configured so that general lighting can Not Applicable
:be controlled separately in control
zones with floor areas <= 600 sq.ft.
:within the space, 2) automatically turn
:off general lighting in all control zones
;within 20 minutes after all occupants
have left the space, 3)are configured
so that general lighting power in each
control zone is reduced by >= 80%of
:the full zone general lighting power
;within 20 minutes of all occupants
;leaving that control zone, and 4)are
:configured such that any daylight
responsive control will activate space
:general lighting or control zone
;general lighting only when occupancy
for the same area is detected.
C405.2.2, Each area not served by occupancy ❑Complies
C405.2.2. sensors (per C405.2.1) have time- ❑Does Not
1, switch controls and functions detailed
C405.2.2. in sections C405.2.2.1 and C405.2.2.2. ❑Not Observable
2 KNot Applicable
[EL21]2
1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3)
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:WEEK Engineering\10000_AVA Mixed Use\Energy Forms110000 AVA Mixed Use-Lighting.cck Page 6 of 9
Section
Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.3, Daylight zones provided with ❑Complies
C405.2.3. individual controls that control the i❑Does Not
1, lights independent of general area
C405.2.3. lighting. See code section C405.2.3 ❑Not Observable
2 Daylight-responsive controls for NNot Applicable
[EL23]2 applicable spaces, C405.2.3.1 Daylight
responsive control function and
section C405.2.3.2 Sidelit zone.
C405.2.4 Separate lighting control devices for ®Complies
[EL26]1 specific uses installed per approved ❑Does Not
;lighting plans. ENot Observable
ENot Applicable
C405.2.4 ;Additional interior lighting power ❑Complies
[EL27]1 :allowed for special functions per the Does Not
;approved lighting plans and is
;automatically controlled and ENot Observable
separated from general lighting. ®Not Applicable
C405.2.5 ;Automatic lighting controls for exterior XComplies
[EL28]no° lighting installed. Controls will be ❑Does Not
daylight controlled,set based on
business operation time-of-day, or ❑Not Observable
reduce connected lighting > 30%. ENot Applicable
C405.3 ;Exit signs do not exceed 5 watts per I Complies
[EL6]1 face. ( Does Not
['Not Observable
❑Nat Applicable
C4Q5 !!:Low-voltage dry-type distribution ❑Complies
[EL2tc , electric transformers meet the ❑Does Not
;a
a minimum efficiency requirements of
�,.i L.c[Table C405.6. ['Not Observable
INot Applicable
C405.7 ' `Electric motors meet the minimum Complies
[EL27]2 efficiency requirements of Tables ❑Does Not
C405.7(1)through C405.7(4). ❑Not Observable
Efficiency verified through certification ❑Not Applicable
rvabl
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer(where certification
programs do not exist).
C405.8.2, Escalators and moving walks comply DComplies
C405.8.2. with ASME A17.1/CSA B44 and have ❑Does Not
1 automatic controls configured to
[EL28]2 reduce speed to the minimum ENot Observable
permitted speed in accordance with L Not Applicable
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
i
C405.9 Total voltage drop across the XComplies
[EL29]2 combination of feeders and branch ❑Does Not
circuits <= 5%.
[Not Observable
ENot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: AVA Mixed Use Report date: 03/22/22
Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 7 of 9
Section
Final Inspection Complies? I Comments/Assumptions
& Req.ID
C303.3, Furnished 0&M instructions for QXComplies CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION
C408.2.5. systems and equipment to the ❑Does Not
2 building owner or designated
[FI1713 representative. ❑Not Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture ®Complies See the Interior Lighting fixture schedule for values.
[FI18]' lighting power is consistent with what ❑Does Not CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION
is shown on the approved lighting
plans, demonstrating proposed watts ❑Not Observable
are less than or equal to allowed ❑Not Applicable
watts.
C405.5.1 Exterior lighting power is consistent ®Complies See the Exterior Lighting fixture schedule for values.
[FI19]1 with what is shown on the approved ❑Does Not CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION
lighting plans, demonstrating
proposed watts are less than or equal ❑Not Observable
to allowed watts. ❑Not Applicable
C408.1.1 Building operations and maintenance [$(Complies CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION
[FI57] documents will be provided to the ❑Does Not
owner. Documents will cover
manufacturers' information, [Not Observable
specifications, programming ❑Not Applicable
;procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
C408.2.5. Furnished as-built drawings for ®Complies CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION
1 electric power systems within 90 days ❑Does Not
[FI16]3 of system acceptance.
❑Not Observable
❑Not Applicable
C408.3 ;Lighting systems have been tested to ®Complies
[FI33]1 ensure proper calibration, adjustment, ❑Does Not CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION
;programming, and operation.
DNot Observable
❑Not Applicable
Additional Comments/Assumptions: