Loading...
Report (3) 1UP W 22 - 00017 OFFICE COPY • COMcheck Software Version 4.1.5.3 Interior Lighting Compliance Certificate RECEIVED Project Information APR 04 2022 Energy Code: 2018 IECC CI l r u- IIGARD Project Title: AVA Mixed Use BUILDING DIVISION Project Type: New Construction -I Construction Site: Owner/Agent: Designer/Contractor: $4 4.2.37 SW Main St Neek Engineering MFIA Tigard, OR 4770 SW Hall Blvd 2007 SE Ash St Beaverton, OR 97005 Portland, OR 97214 503-234-0548 Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Future Retail Spaces(Retail:Sales Area) 5287 1.10 5816 2-Stairs(Common Space Types:Stairwell) 968 0.52 503 3-Equipment Rms(Common Space Types:Electrical/Mechanical) 670 0.39 261 4-Lobby(Common Space Types:Lobby-General) 277 0.90 249 5-Corridor(Common Space Types:Corridor/Transition<8 ft wide) 1925 0.59 1136 Total Allowed Watts= 7965 Proposed Interior Lighting Power A B C D E Fixture ID : Description I Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Future Retail Spaces(Retail:Sales Area) LED 1:Al:4ft Gen Purp Strip: LED Panel 36W: 1 25 35 875 2-Stairs(Common Space Types:Stairwell) LED 2:B1:4ft wraparound:LED Linear 22W: 1 14 25 350 3-Equipment Rms (Common Space Types:Electrical/Mechanical) LED 3:Al:4ft Gen Purp Strip:LED Panel 36W: 1 9 35 315 LED 4:B1:4ft wraparound:LED Linear 22W: 1 2 25 50 4-Lobby(Common Space Types:Lobby- General) LED 5:B2:8ft recessed strip:LED Linear 22W: 1 4 26 104 5-Corridor(Common Space Types:Corridor/Transition <8 ft wide) LED 6:C1:4"downlight:LED PAR 16W: 1 54 16 864 Total Proposed Watts= 2558 Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:\NEEK Engineering\10000_AVA Mixed Use 1Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 1 of 9 • y � PO** Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Denise Taylor, Elect. Designer Denise Taylor 03.22.2022 Name-Title Signature Date Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 2 of 9 COMcheck oft are Version .1.5.3 Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: AVA Mixed Use Project Type: New Construction Exterior Lighting Zone 2(Residential mixed use area(LZ2)) Construction Site: Owner/Agent: Designer/Contractor: 12537 SW Main St Neek Engineering MFIA Tigard,OR 4770 SW Hall Blvd 2007 SE Ash St Beaverton, OR 97005 Portland, OR 97214 503-234-0548 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Entry Canopies(Entry canopy) 1651 ft2 0.25 Yes 413 Parking areas(Parking area) 5214 ft2 0.04 Yes 209 Total Tradable Watts(a)= 621 Total Allowed Watts= 621 Total Allowed Supplemental Watts(b)= 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/ Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Entry Canopies (Entry canopy 1651 ft2):Tradable Wattage LED 1:Si: Ext.Chg.Light:LED PAR 11W: 1 6 11 66 LED 2:S2:4"downlight:LED PAR 16W: 1 9 16 144 LED 3:S3: Ext.Wall Sconce: LED A Lamp 25W: 1 12 22 264 LED 4:S4: Ext.wall Pack: LED A Lamp 25W: 1 3 24 72 Parking areas( Parking area 5214 ft2):Tradable Wattage LED 5:S5:4ft Enclosed Strip:LED Panel 41W: 1 8 42 336 LED 6:S6:Pole Mnt Area Light: LED Roadway-Parking Unit 42W: 1 3 38 114 Total Tradable Proposed Watts= 996 xteruor Lighting PAS . ti 2% bet Cod Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:INEEK Engineering110000_AVA Mixed Use\Energy Forms110000 AVA Mixed Use-Lighting.cck Page 3 of 9 Denise Taylor, Elect. Designer Denise Taylor 03.22.2022 Name-Title Signature Date Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 4 of 9 COMcheck Software Version 4.1.5.3 Inspection Checklist Energy Code: 2018 IECC Requirements: 69.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review I Complies? Comments/Assumptions & Req.ILl C103.2 ;Plans, specifications, and/or IIMComP lies [PR4]1 calculations provide all information ❑Does Not with which compliance can be ;determined for the interior lighting ['Not Observable land electrical systems and equipment ❑Not Applicable ;and document where exceptions to ;the standard are claimed. Information provided should include interior lighting power calculations, wattage of :bulbs and ballasts,transformers and :control devices. C103.2 :Plans,specifications, and/or [Complies [PR8]1 calculations provide all information ❑Does Not ;with which compliance can be determined for the exterior lighting ['Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. C406 ,Plans, specifications, and/or ti(7Complies [PR9]1 calculations provide all information ❑Does Not ;with which compliance can be determined for the additional energy ['Not Observable :efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 5 of 9 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. ;Spaces required to have light- /SCornplies 2 ;reduction controls have a manual ❑Does Not [EL22]1 control that allows the occupant to ;reduce the connected lighting load in ❑Not Observable a reasonably uniform illumination ❑Not Applicable pattern >= 50 percent. C405.2.1, ;Occupancy sensors installed in ❑Complies C405.2.1. :classrooms/lecture/training rooms, ❑Does Not 1 conference/meeting/multipurpose [EL18]1 ;rooms,copy/print rooms, ❑Not Observable ;lounges/breakrooms, enclosed offices, INotApplicable ;open plan office areas, restrooms, ;storage rooms, locker rooms, warehouse storage areas, and other ;spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. ;Reference section language C405.2.1.2 for control function in ;warehouses and section C405.2.1.3 ;for open plan office spaces. C405.2.1. Occupancy sensors control function in ❑Complies 2 warehouses: In warehouses, the ❑Does Not [EL19]1 lighting in aisleways and open areas is controlled with occupant sensors that ❑Not Observable :automatically reduce lighting power ®Not Applicable by 50%or more when the areas are :unoccupied.The occupant sensors :control lighting in each aisleway :independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. Occupant sensor control function in ❑Complies 3 :open plan office areas: Occupant ❑Does Not [EL20]1 sensor controls in open office spaces ❑Not Observable I>= 300 sq.ft. have controls 1) :configured so that general lighting can Not Applicable :be controlled separately in control zones with floor areas <= 600 sq.ft. :within the space, 2) automatically turn :off general lighting in all control zones ;within 20 minutes after all occupants have left the space, 3)are configured so that general lighting power in each control zone is reduced by >= 80%of :the full zone general lighting power ;within 20 minutes of all occupants ;leaving that control zone, and 4)are :configured such that any daylight responsive control will activate space :general lighting or control zone ;general lighting only when occupancy for the same area is detected. C405.2.2, Each area not served by occupancy ❑Complies C405.2.2. sensors (per C405.2.1) have time- ❑Does Not 1, switch controls and functions detailed C405.2.2. in sections C405.2.2.1 and C405.2.2.2. ❑Not Observable 2 KNot Applicable [EL21]2 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:WEEK Engineering\10000_AVA Mixed Use\Energy Forms110000 AVA Mixed Use-Lighting.cck Page 6 of 9 Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, Daylight zones provided with ❑Complies C405.2.3. individual controls that control the i❑Does Not 1, lights independent of general area C405.2.3. lighting. See code section C405.2.3 ❑Not Observable 2 Daylight-responsive controls for NNot Applicable [EL23]2 applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for ®Complies [EL26]1 specific uses installed per approved ❑Does Not ;lighting plans. ENot Observable ENot Applicable C405.2.4 ;Additional interior lighting power ❑Complies [EL27]1 :allowed for special functions per the Does Not ;approved lighting plans and is ;automatically controlled and ENot Observable separated from general lighting. ®Not Applicable C405.2.5 ;Automatic lighting controls for exterior XComplies [EL28]no° lighting installed. Controls will be ❑Does Not daylight controlled,set based on business operation time-of-day, or ❑Not Observable reduce connected lighting > 30%. ENot Applicable C405.3 ;Exit signs do not exceed 5 watts per I Complies [EL6]1 face. ( Does Not ['Not Observable ❑Nat Applicable C4Q5 !!:Low-voltage dry-type distribution ❑Complies [EL2tc , electric transformers meet the ❑Does Not ;a a minimum efficiency requirements of �,.i L.c[Table C405.6. ['Not Observable INot Applicable C405.7 ' `Electric motors meet the minimum Complies [EL27]2 efficiency requirements of Tables ❑Does Not C405.7(1)through C405.7(4). ❑Not Observable Efficiency verified through certification ❑Not Applicable rvabl under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer(where certification programs do not exist). C405.8.2, Escalators and moving walks comply DComplies C405.8.2. with ASME A17.1/CSA B44 and have ❑Does Not 1 automatic controls configured to [EL28]2 reduce speed to the minimum ENot Observable permitted speed in accordance with L Not Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. i C405.9 Total voltage drop across the XComplies [EL29]2 combination of feeders and branch ❑Does Not circuits <= 5%. [Not Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms\10000 AVA Mixed Use-Lighting.cck Page 7 of 9 Section Final Inspection Complies? I Comments/Assumptions & Req.ID C303.3, Furnished 0&M instructions for QXComplies CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI1713 representative. ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ®Complies See the Interior Lighting fixture schedule for values. [FI18]' lighting power is consistent with what ❑Does Not CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION is shown on the approved lighting plans, demonstrating proposed watts ❑Not Observable are less than or equal to allowed ❑Not Applicable watts. C405.5.1 Exterior lighting power is consistent ®Complies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved ❑Does Not CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION lighting plans, demonstrating proposed watts are less than or equal ❑Not Observable to allowed watts. ❑Not Applicable C408.1.1 Building operations and maintenance [$(Complies CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION [FI57] documents will be provided to the ❑Does Not owner. Documents will cover manufacturers' information, [Not Observable specifications, programming ❑Not Applicable ;procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. C408.2.5. Furnished as-built drawings for ®Complies CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION 1 electric power systems within 90 days ❑Does Not [FI16]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.3 ;Lighting systems have been tested to ®Complies [FI33]1 ensure proper calibration, adjustment, ❑Does Not CONTRACTOR TO PROVIDE UPON PROJECT COMPLETION ;programming, and operation. DNot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: AVA Mixed Use Report date: 03/22/22 Data filename: G:\NEEK Engineering\10000_AVA Mixed Use\Energy Forms110000 AVA Mixed Use-Lighting.cck Page 8 of 9