Permit a CITY OF TIGARD MASTER PERMIT
COMMUNITY DEVELOPMENT Permit#: MST2022-00155
Date Issued: 07/28/2022
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 251070002000
Jurisdiction: Tigard
Site address: 16820 SW COLORADO LN
Subdivision: Lot:
Project: South River Terrace, Lot 4
Project Description: New detached dwelling. REPRINT to add 190 sf deck.
BUILDING
Floor Areas Required Setbacks Required
Stories: 2 Bedrooms: 5 First: 1353 sf Basement: 0 sf Left: 3 Parking Spaces: 0
Height: 25.5 Bathrooms: 3 Second: 1852 sf Garage: 439 st Front: 12 Smoke
Yes
Dwelling Units: 1 Third: 0 sf Right: 3 Detectors:
Total: 3205 sf Value: $445,892.42 Rear: 15
PLUMBING
Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0
Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100
Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 100 Ice Maker. 1 Hose Bib: 2 Backwater Value: 1
Other Fixtures: 0
Drywell-Trench Drain: 0 Other Fixture Units:
MECHANICAL
Fuel Tvpes Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1
Natural Gas Heat Pump; N Hoods: 1 Other Units: 0
Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add1500 sf: 6 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System; N Garage Opener: N All Y
Other: N Other Description: Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 3205
Owner: Contractor:
TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions)
703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175
VANCOUVER,WA 98860 VANCOUVER,WA 98660
PHONE: PHONE: 360-695-7700
FAX:
Total Fees: $28,443.43
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oc9_nn1JNHn fhrnu. AR 0S9_nn1 qi/' v nCnv of tho n doe nr riire 1 ni mefinnc fn ill INC:by Tallinn Fflq 979 100.7 nr 1 Finn 149 9'idd
a, Permittee Signature: �� CQ�f �
Issued By: j I
503.639.4175 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
City of Tigard
1111 COMMUNITY DEVELOPMENT DEPARTMENT
C
Building Permit Review — Residential
TIGARD
Building Permit #: rbT -K .--061 S5
Site Address: 100Z4 CO\oao0 LVI.
Project Name: 50Jctn f4Jet( ix/rya C . Lot #: LI
Planning Review � k (9
Proposal: I (n�ri Verify address/suite#active in Accela. X In River Terrace: ❑ No pi Yes,River Terrace Review Addendum
Sl Plan Elements: Erosion Control,
�eetinn measures
3 copies of site plan on 8-1/2"x 11"or 11 x 17 paper }trtailaPd tyres frith-�lirra+�d-tree����
rawn to scale(standard architect or engineer scale) Footprint of new structure(including decks)and NNE
orth arrow Utility locations&easements(required for new and additions)
(Site address,project or subdivision name and lot number Widewalk/driveway approach
Applicant information(name and phone number) Al=n.,.ati,,..of wells/septic systems
of dimensions and building setback dimensions PStreet tree size,type and location
OStreet names
flneicting_Sty,r+yra8 on,.ice Worner elevations(2'contours if more than 4'differential)
LLot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? FYes ❑No
impervious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? ❑YeXNo
Ig. Clean Water Services—Service Provider Letter (lot platted prior to 9/10/1995):
(.4 Required: 0 Yes,applicant was notified g No Received: ❑ Yes El No
Oil Water Meter Fixture Unit Worksheet—Additions,Remodels and ADUs
Required: 0 Yes,applicant was notified @ No Received: 0 Yes ❑ No
0 SDC Exemption for ADU applied for: 0 Yes 0 No Received: ❑ Yes ❑ No
[ Public Facilities Improvement(PFI)Permit:
Required: El Yes,applicant was notified No Applied For. CIYes ❑ No,stop intake
P Land Use Case#: -PP i`—�.0 4.1(l i 3 j2 i Zoning: 7----
yRequired Setbacks: Front: �Z` Rear: , Side: '3I Street Side: `�I Garage: � 1
rtgb Building Height Max. Height: 35 Actual Height:
Landscape Area: 7....2) % A Lot Coverage Max:
Entrance Set back no more than 8'from street-facing wall Parallel to street or offset 45 degrees or less
Windows A Minimum 12%of area of all street-facing facades
Garage r Garage door is behind widest street-facing wall ,E7Yes ❑ No,one of the following is met:
❑ Door extends no more than 5'from wall and there is a covered porch extending beyond garage.
❑ Door extends no more than 5'from wall and there is a 12 sq ft.window above garage on 2.d floor.
pGarage door width is ❑ 12'or less , 50%or less of facade 0 60%or less and includes 7 of following:
❑ Covered porch ❑ Recessed entrance ❑ Wall offset 0 1'Roof cave ❑ Roof offset
❑ Fire shingles ❑ Lap Siding 0 Roof pitch ❑ Gable,hip,or gambrel roof 0 Dormer
❑ Accent siding 0 Window trim ❑ Window recess ❑ Window projection El Balcony
Visual Clearance A Urban Forestry Plan
Sensitive Lands: ❑ Yes $ No Type:
l Conditions� met,prior to issuance of building permit
Notes: M.wG►c��Vtr f— :,t tV,,G,. q.., ,,,,,, 07, --,,,,„„‘;.
p Approved By Planning: 1 a'A 4 I�Z�L Date:
Revisions (afte B jjlding Submittal only) Reviewer Date
Revision 1: /l�Approved ❑ Not Approved P/3(LZ
Revision 2: ❑ Approved ❑ Not Approved