Specifications
W YAT T FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 LUSH WASH SQ 9585 SW WASHINGTON SQUARE, SPACE G01 TIGARD, OR 97223 PLEASE PROVIDE OFFICE COPY COMPLETED NFPA 13 CITY OF TIGASI) MATERIAL AND TEST REVIEWED FOR CODE COMPLIANCE CERTIFICATE AT Approved: �[�! ) FINAL INSPECTION OTC: ( ] Permit#: _A Address: S s d L,L c- I , S Suite By: Dom r =a 3 -1. FIRE PROTECTION EQUIPMENT SUBMITTAL VALIDITY OF PERM THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 t[jc© Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers "" ° Description described herein must be installed and maintained in compliance with this doc- The TYCO SeriesTY-FRB,5.6 K-factor, ument, as well as with the applicable ,," Upright (TY313) and Pendent (TY323) standards of the National Fire Protec- f' ./ Sprinklers described in this data sheet tion Association, in addition to the stan- . .;, are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair sprinklers designed for use in light or the performance of these devices. •'"" .�:i.. ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler, where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed p Escutcheon with recessed adjust- Identification '' ' merit up to 5/8 inch (15,9 mm) from 4 the flush pendent position. Number(SIN) • A two-piece Style 20 Recessed r' Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2•"NPT i ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT a > : • the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe'drops 135 F(57°C) to the sprinklers must becut. Data 155°F (68°C) 175°F (79°C) Intermediate level versions of Series Approvals 200°F (93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F (141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB, and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet T F P780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon: White Coated, tant Sprinklers. Chrome Plated, or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi (12.1 bar) Frame Bronze 250 psi (17.2 bar)* Button Brass/Copper The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories, Inc. (UL). Bulb Glass Sheet TFP700 for the"INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psii/2(80,6 LPM/barl'2) Deflector Bronze with respect to handling and instal- lation of sprinklersystems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation orcause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 -Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 -Compression STYLE 15 or 20 3 -Sealing Screw ESCUTCHEON PLATE 1-/2" 7/16"(11,1 mm) RECESSED Assembly 6 -Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 5 7/16" (11,1 mm) \ \_..-7 I— 1 4 NOMINAL 2" + I) (I MAKE-IN (50,8 mm) 2 2" 1-3/8" 3 (50,8 mm) (34,9 mm) T WRIENCH _ FLATS 1 1/2"NPT** DEFLECTOR* -- 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE c. Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water toflow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- Criteria ble should be present. The diameter WRENCH of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. l- �� tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min- Approval agency (such as, UL Listing 41 imum to maximum torque of 7 to 14 ft.- is based on the requirements of NFPA lbs. (9,5 to 19,0 Nm). Higher levels of 13, and FM Approval is based on the torque can distort the sprinkler Inlet %volerequirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 orStyle of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 • Step 3. Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF (57,2 mm) Torque sprinklers 7 to 14ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i \ FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" Sprinklers must be installed in accor- (9,5±7,9 mm) `"- % } _ dance with the following instructions. Step A.After installing the Style 15 or ' MOUNTING 1/8" � Style 20 Mounting Plate overthe sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread — sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. FIGURE 4 Step B. Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench(Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceilinginstallation and fin- SPRINKLER 2-1/4"DIA. — fishing, slide on the tyle 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16t1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in + FLUSHI contact with the ceiling. Care and t I f MOUNTING 1/8" Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, Upright (TY313) and Pendent (TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) TY-FRB PLATE Sprinklers must be maintained and ser- 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced, standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion,but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage, or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing, and maintenance of sion must be replaced. theirfire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- ofthe National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX � I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 13'- 135°F(57°C) 370 5.6K UPRIGHT(1/2-NPT) TY313 3 PURE WHITE 10)°° POLYESSTERTER 15E 155°F(88°C) SIGNAL WHITE(RA L9003) 371 5.6K PENDENT(1/2-NPT) TY323 4 POLYESTER 175 175°F(79°C) Use suffix"I"for ISO 7-1 connection, 9 CHROME PLATED 20C 200°F(93°C) for example,77-370-4-175-I Eastern Hemisphere sales only 28E 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with(specify*)finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*)finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP.All rights reserved. t"cu TEFLON is trademark of The DuPont Corporation. Fire P,otectrorr Products 9' Ductile Iron Fittin.s-Class 300 UL FM I c;.sa ttw;a c ® us LISTED APPROVED Fig. 35F 3 - 90° Elbow A Size Part Number A Packing Weight in in Inner Master lb Illi Ilk 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 ill A 1 35E 3010 1.50 40 80 0.5 !j 1-1/4 35E 3012 1.75 25 50 0.8 _ 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 90° Reducing Elbow SBB Size Part Number A B Packing Weight W in in in Inner Master lb 111% 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 Wm) �A1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0,6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1_.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1-97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3 - 45° Elbow Size A Packing Weight Part Number in in Inner Master lb 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 isti1 35F 3010 13 40 80 0.7 � 1-114 35F 3012 1.29 25 50 0.7 T1-1/2 35F 3014 1.44 20 40 1.0 A in .1 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1,95 4 8 2 7 Fig. 35T 3 - Tee Size Part Number A Packing Weight in in Inner Master lb M lA 1/2 351 3004 1 13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 # . 1 11 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 /// SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323) 890-1156 • www.smithcooper.com Ductile Iron Fittin:s-Class 300 UL FM c ® us LISTED APPROVED A A Fig. 35X 3 - Cross ` '.. ' Size A Packing Weight Part Number p in in Inner Master___ lb p A 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 '� II v 1-112 35X 3014 1.94 8 16 1.8 ►N,I�I�� �A 2 35X 3020 2.25 6 12 2.8 B B Fig. 35RX3 - Reducing Cross ` ' Size A B Packing Weight lip rA in Part Number in in Inner Master lb 1-1/4 x 1 35RX3012010 1,67 1,58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 A 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3 - Cap Size Part Number A Packing Weight inin Inner Master lb f ill A 1/2 350 3004 I 0.87 300 600 0.1 314 35C 3006 0.97 200 400 0.1 I _ 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1,6 Fig. 35BC3 - Beam Clamp pitSize A Packing We[ rt �� Part Number A in in Inner Master 35630075 ■� 1/2 356C3004 0.75 80 160 0_5 SMITII-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smitheooper.com 114 Threaded Accessories B3205-Threaded Rod(right-hand threads-both ends)(TOLCOFig.103) B3205L - Threaded Rod (right & left hand threads) / TL l� Size Range: 3/8"-16 thru 3"-4 rod Specify Length - %,‘' Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL 1 Rod is threaded on both ends with right hand threads of the length shown.Also �1����1)ll A available with left and right hand threads-specify Fig.B3205L when ordering. Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL bait. (343`c) rou-I- (3991c) . Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 1332053/8x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205 112x'L' 1/2' 13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8x'L' 5/8"-11 21/2" (9.61) 1692 B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" --- ---- (1993) 3508 Ii (88,9) 4480 (15.60) B3205-1 x'L' 1"-8 4" ( (26 24) 4620 (20.55) B3205-11/8 x'L' 11/e"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 83205-11/4x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" 1962 (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4x'L' 21/4"-41/2 9 (228.6) 32300 (143 67) 25295 (112.51) B3205-21/2x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" i (304.8) 60100 (267 32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length ?vL � l Size Range: 3/8%16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length 714).., Material: Steel 1110011 N Maximum Temperature: 750°F(399°C) "" a o Finish: Plain. Contact B-Line for alternative finishes and materials. t V Order By: Part number, rod diameter and finish I- e d Part No. -Size x Length Threads Recommended Load Approx.Wt./100 Ft. A lIt lig.99 Per Inch 'Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-114"x length 20 240 (1.07) 12 (5.44) ATR 3/s"x 120 99-31a"x length 16 730-_- 9 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 9 (6.00) 53 (24.04) ATR 5/a"x 120 99-3/4"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-1/4"x length 10 3230 (14.37) 123 (55.79) ATR 7la"x 120 99.7/s"x length 9 4480 g (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Pipe Hangers&Supports236 Revised 4/28/2014 by IIF:T•N