Loading...
HomeMy WebLinkAboutPermit FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. 14 City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT s is Transmittal Letter T I cG A R D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Tigard Building Dept. DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED FROM: Michael Distifeno bpp 6 2023 COMPANY: Wyatt Fire Protection CITY OF TIGAR® BUILDING DNIS GN PHONE: 503 684 2928 By EMAIL: M.distifeno@wyattfire.com RE: 9610 Sw Washington Square Rd, Suite G01 FPS2022-00156 (Site Address) (Permit Number) Lush (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: 3 Additional set(s) of plans. Revisions: Added 6 sprinkler heads Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. 3 Other(explain):Equipment Package REMARKS: Original plans showed western-most area of work as sprinklered,this was incorrect and area was lacking sprinkler coverage. Revised plans have been updated with new sprinkler heads in that area. FOR OFFICE USE ONLY Routed to Permit Technician: Date: U - 19- a._,3 Initials: Fees Du NUJ Y w L No Fee Description: Amount Due: $ $ $ Special Instructions: Reprint Permit(per PE): ❑ Yes - No ❑ Done Applicant Notified - Date: C-02 6 3 Initials:,/f I:\Building\Forms\TransmittalLetter-Revisions 073120.doc RECEIVED APR 6 2023 CITY OF TIGARD BUILDING DIVISION w AT T s r . r s FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 LUSH WASH SQ 9585 SW WASHINGTON SQUARE, SPACE G01 REVISION TIGARD, OR 97223 FILE COPS CITY OF TIGARD, REVIEwiD FOR CODE COMPLIANCE Approved: 4.1I OTC: [ J Pcrmit#: F p S t") 0 Address: 9 r.„tj W c,s y, Suite#: ST21 _ By: --f1I , Date: y- ) g_ Z3 PLEASE PROVIDE COMPLETED NFPA 13 MATERIAL AND TEST 4 CERTIFICATE AT FINAL INSPECTION FIRE PROTECTION EQUIPMENT SUBMITTAL tL,C13 Worldwide www.tyco-fire.com Fire Protection Contacts Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers • Description described herein must be installed and maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright (TY313) and Pendent (TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association, in addition to the stan- ' ; are quick response,standard coverage, dards of any other authorities having , decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair `'' sprinklers designed for use in light or the performance of these devices. ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: Sprinkler I • A two-piece Style 15 Recessed - , k Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm)from .'tom the flush pendent position. Nurnber(S/N)11-N °: ... 4 . - tiiir . X`` ; • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT AA ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT ry' the flush pendent position. . ;; The adjustment provided by the Technical r. Temperature Rating Recessed Escutcheon reduces the , .;,,,.-435°F.(57°C) accuracy to which the fixed pipe drops """ ' to the sprinklers must becut. Data 155°F (68°C) 175°F (79°C) Intermediate level versions of Series Approvals „�„,�004 (93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F (141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB, and VdS Approved kler guards and shields are described CE Certified Finishes a in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated t Maximum Working Pressure Physical Characteristics , 175 psi (12.1 bar) Frame Bronze 250 psi (17.2 bar)* Button Brass/Copper Sealing maximum working pressure of 250 psi Sea g Assembly StainlessSteel w/TEFLON IMPORTANT (17.2 bar)only applies to the listing by Un- Always refer to Technical Data derwriters Laboratories, Inc. (UL). Bulb Glass Sheet TFP700 for the"INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psiv2(80,6 LPM/bar112) Deflector Bronze with respect to handling and instal- lation ofsprinklersystems and com- ponents. Improper handling and installation can permanently dam- age a sprinklersystem or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 -Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 -Compression STYLE 15 or 20 3 -Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 -Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* ' r 5 7/16" (11,1 mm) \ - 1 / 4 NOMINAL 2" } I_� �_i MAKE-IN (50,8 mm) I ') 2 2" �II (I/ 1 3/8" 3 (50,8 mm) 1 (34,9 mm) f WRENCH 1 Tj FLATS , 1 1 7-± — i 1/2"NPT** DEFLECTOR* 1-.. -- 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation Installation \ The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- WRENCH Criteria ble should be present. The diameter RECESS of the air bubble is approximately 1/16 The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. if tion systems designed in accordance with the standard installation rules rec- leak tight 1/2 inch NPT sprinkler joint ognized by the applicable Listing or should be obtained by applying a min .,,iiii "..r It Approval agency (such as, UL Listing imum to maximum torque of 7 to 14 ft.- is based on the requirements of NFPA lbs. (9,5 to 19,0 Nm). Higher levels of 414 r 13, and FM Approval is based on the torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment IN TO ENSURE Data Sheets).Only the Style 15orStyle of the sprinkler. ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) - 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i t FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" r (I 7 Sprinklers must be installed in accor- (9,5±7,9 mm) dance with the following instructions. r \ _-- Step A. After installing the Style 15 or MOUNTING 1/8 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm)� kler threads, and with pipe-thread sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. FIGURE 4 Step B. Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench(Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF SPRINKLER 2-1/4"DIA. Step C.After ceiling installation and fin- FITTING (57,2 mm) ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- 5/16±1/4" 1/2"(12,7 mm) kler and push the Closure over the (7,9±6,4 mm) Mounting Plate until its flange comes inin FLUSH contact with the ceiling. =j \T32 , ,7 i Care and t �� MOUNTING 1/8' i Maintenance SURFACE mm) The TYCO Series TY-FRB,5.6 K-factor, Upright (TY313) and Pendent (TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced_ standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion,but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, i a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage, or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing, and maintenance of sion must be replaced. theirfire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- ofthe National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 13E 135°F(57°C) 370 5.6K UPRIGHT(1/2-NPT) TY313 3 PURE WHITE(RAL9010)** POLYESTER 155 155°F(68°C) 371 5.6K PENDENT(1/2-NPT) TY323 4 SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) *Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED for example,77-370-4-175-I 20C 200°F(93°C) *"Eastern Hemisphere sales only 28E 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*)finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*)finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP.All rights reserved. f't,/co TEFLON is trademark of The DuPont Corporation. fire Protection Products . : :''''';'''J->c"`:"%lli-tere':.f.*.%. , 101 ( -15''-'-'''.:::,,f.: 1:2'.. . e''''' fig. ff1LW 4-1740'ieZP,,-,,,:tv e,:t,--.7,:,.. ( F wry, 4. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size(Inches) 1" 1-1/4" 1-1/2" 2" 2-1i2" 3" 4" 6" 8" NPS(In.) 1" 1.114" 1.112" 2" 2.112" 3" 4" C O.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 C 1.315 1.660 1.900 2.375 2875 3.500 4.500 e- 1,p.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 d' 1.049 1.380 1.610 2.067 2.469 3.068 4.026 JEmpty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 J 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water Filled Weight(lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 2.055 2.918 3.602 5.114 7.875 10.783 16.316 al' CRP. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 CI 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Z Pieces per Lift: 91 61 61 37 30 19 19 10 7 Z 70 51 44 30 30 19 19 .) ift Weight(lbs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 U 2,470 2,431 2,513 2,306 3,654 3,024 4,309 Cl)) Lift'Weight Ohs)24'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 2,822 2,778 2,872 2,635 4,176 3,456 4,925 Lift Weight fibs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 2,940 2,894 2,992 2,745 4,350 3,601 5,130 SCHEDULE 10 & 40 ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved • We have the most stocking locations in the industry, for best delivery and availability • ASTM A13S and A795 Type E,Grade A Certified • Plain end or roll groove • Complies with NFPA-13, 13R and 14 • Eddy Guard li"`bacterial-resistant internal coating • Industry-leading hydraulic characteristics • Custom length options • CRR of 1.0 and greater , • Hot dipped galvanization •" All pipe NOT weld tested • Reddi-Pepee red or black pipe eliminates field painting • Compatible for use in wet,dry,preaction anddeluge sprinkler systems Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. a The only maker with EPDs(to help earn LEED points). Cr-a) ilt pil A= CC )US us LISTED OAFSAAPPROVED 'arptitc .,. ,. . . ... , ii 1 l ' ' ' 1%/[OOSE f BULL BullMooseTube.com Ductile Iron Fittin's-Class 300 UL/FM . 11 c CIO us APPROVED LISTED Fig. 35E 3- 90° Elbow A r Size pad Number A Packing Weight , in in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 , t i 3/4 ., 35 : 5 1. 1 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 I1!A 1-1/4 3'rE 3012 ;" 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 3: 3020 225 10 , 20 1.$ 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 90° Reducing Elbow B Size Part i umberA• B Packing Weight re, in in in . Inner Master" lb 1 , 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1-X 112 36RE301 04 1.26 36 70 140- : 0.4 - 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 A 1-1/4-x 1/2 _ 35RE3012004 1. 4 - 1,53 :35- 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-114 x 1 350E3012010 1,58 : 1,67 30 - 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 351E3014008 s': - 152 1.75 - 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x 1-1/4 50 3014612, 182 1_88 . . 18 36 '1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE302 . . - 1.80 .1,97 ; 18 36°„ : 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4- 3 RE t20012 - 1.90 2.10' ;;12 24"., _ 1»3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 11 2-1/2 x 1-1/2 360E3024014 'i 2.16 2.551- ; 6 , 12 2,2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3 - 45° Elbow x Size Part NumberA Packing Weight , ` q in in inner"_ ,, Master'. lb itt�, 1/2 35F 3004 0.88 150 300 0.2 . 4 3 , 06 : O': S0° . 160 0.3 1 35F 3010 1.13 40 80 0.5 ip 9 1 1i4 35 `3012 1. 9 5 50 0.r _ 10 I IA 1-1/2 35F 3014 1.44 20 40 1 0 -` i�l - 2 35F 3020 1. 10` 20: 1.6 - 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3 - Tee Size Part Number. A Packing Weight I;�� in innne Master lb 1/2 35T 3004 1.13 80 160 0.3 A 3/4 361 3006 1.31, ' 30 60 - -li _i 1 35T 3010 1.50 25 50 0=3 0.7 �*��.��� -, 1.-114 ,35T,. 012 1.75 10 20. 1.1 e A )'f A-' 1-1/2 35T 3014 1.94 10 20 1.5 2-1/2 35T 3024 2.70 4 8 4.3 /// SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Ductile Iron Fittin:s-Class 300 UL/FM c04) us LISTED APPROVED Fig. 35CP3 -Straight Coupling with Ribs • ASize , Packing Weight in Part Number kn Inner Master ` lb 1111111111 iimarr 1/2 35CP3004 1.38 200 400 0.1 1 35CP3010 1.75 60 120 0.4 1-114 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 ' 30 1-2 2-1/2 35CP3024 3.00 9 18 2 2 Fig. 35RC3 - Flex Reducing Coupling Size Part Number A Packing Weight B in in Inner Master; lb A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3t4 3�301 6 1.69 60_- 120 0.4 �' 1 1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1(not 11ex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 - Hex Bushing Size A Packing Weight in Part Number in inner Master lb l3 1 x 1/2 35HB3010004 1.06 180 360 0.2 III 1 !"c � 1 x 14 35NB3010t 6 1 06 180 360 ' 0.1 1-1/4 x 1 35HB3012010 3 1.19 90 180 0.2 1-1/2 x 1 - 35 3014010 1.25 75 _- 150' 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 11 2 x 1 31483020010 1.38 40 80 0.611 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x1-112 351 3020014. 1,36 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part<Number A Packing Weight in inner , `Master lb 1/2 35SP3004 0.94 600 1200 0.07 3/4 35P3006 1.12 350, 700 0.1 1 35SP3010 1.25 200 400 0.1 ,. , 1-114 35SP3012 1.37 100 200 0.3 ff # 1-1/2 35SP3014 1.44 80 160 0.4 2 , 35SP3020 1,50 45, 90 0,6 Fig. 35U 3 - Union with Brass Seat A Size A Packing Weight • ' in Part Numberimml in inner Master lb sweigamio 1 35U 3010 2.19 20 40 1.0 I I 1-114 350 3012 2 50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 j'' - 2 3 1J 3020 r, 3=12 &- 12.,_ 2.4 - - 113 SMITH-COOPER INTERNATIONAL'"• TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smithcooper.com Ductile Iron Fittin:s-Class 300 UL FM 1 c ® us 4411> Fig. 35X 3- Cross LISTED APPROVED ` A ''` A ' Size Part Number Packing„ Weight ;ICI in in inner. aster:, lb ab, '� 1 35X 3010 1.50 20 40 0.9 �� 11 1-1/4 35X 12 1.75 12 24` ' 1.4 1 1/2 35X 3014 1.94 8 16 1.8 �z filj A 21/ 3xXX 30 , 2.z 12 -. ( B B Fig. 35RX3 - Reducing Cross Size iihne SonH i in Part Number n i3 in Packing Weblbht IA• 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1..80 1.65 12 24 . 1,4 ;. A 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size Part Number_ A Packing Weight inin inner Master ` lb ' ,, ,,,„ - '/A .., ... A 1/2 35C 3004 0.87 300 600 0.1 3/4 36C 3006 0.i!►I .1 1 35C 3010 1.16 110 220 0.2 1-1' 35C 3012 1. 8 70 ;'140 Cj 4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 5t1 0,8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp -- Sire Part Number; A Packing Wei ht Al in - in a Inner` Master lb ii6 jig. 3/8 35BC3003 0.75 100 200 0.3 O lli 112> 358C3004 0.75 80 '7 , 180 0.5 SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-8(10-766.0076 • FAX(323) 890-4456 • www.smithcooper.com 114 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger(B-Line Fig. B317ONF) Fig. 200F "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) CC)1.18 Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) USTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200-1/2"(15mm)thru 8"(200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function:Forfire sprinkler and othergeneral piping purposes.Knurled " swivel nut design permits hanger adjustment after installation. r '-_4\ Features: /m - (/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe / types and protectCPVC plastic pipe from abrasion.Captured design / / . keeps adjusting nut from separating with hanger. Hanger is easily �Q `--,`� B j installed around pipe. ` 'i A For hanger with non-captured nut order Fig. 200S. I • (21/2"(65mm)thru 8"(2oomm))Spring tension on nut holds it securely in / ( $,,, -- hanger before installation.Adjusting nut is easily removed. r• Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (2oomm)) -' Fig.200-1Iz.200 314 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.200.1 to 200-2 /// Fig.200-21Izto2 0-8 Factory Mutual Engineering Approved (FM)(3/4" (20mm)thru 8" (20omm)). Conforms to Federal Specifications W W-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, atoi- Type 10. Maximum Temperature:650°F(343°C) Finish: Pre-Galvanized. Stainless Steel . . materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size �; Designed to meet or exceed requirements of FM DS 2-0. `', Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200.112 1/2" (15) ` 318"-16 3118" (79.4) 25/8" (66.7) 11 (5.0) 200.3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1 (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-1114 1114" (32) 3/8"-16 3314" (94.0) 27/8" (73.0) 13 (5.9) L7 200-1112 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) r 9 200-2 2" (50) 318"-16 4112" (114.3) 3" (76.3) 15 (6.9) ;a.: 200-2112 , 21/2" (65) 318"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 318"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-3112 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 318"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 112"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 13-Line Fire Protection Solutions 21 by IF:H Threaded Accessories B3205-Threaded Rod(right-handthreads-bothends)(TOLCO Fig.103) i B3205L -Threaded Rod (right & left hand threads) / TL Size Range: 3/9" 16 thru 3" 4 rod Specify Length < Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TLl Rod is threaded on both ends with right hand threads of the length shown.Also 11111�1�� A available with left and right hand threads-specify Fig.B3205L when ordering. ���� Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Desigr Load Thread Size Thread Length TL b9u'r (343"C) ibu-h (399 C( Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3200-318 x „` 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205 1l2 x`L' ` 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5l x'..' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 32 .314X'4: 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7I8X'L' 7/8' 9 31/2' .._- (88.9) 4480 (19.93) 3508 (15.60) 32t 5= x " . 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-1. l8 t'L'_ 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 63205.11'4x'L' 1114"-7 5" (127.0) 9500 (42.25) 7440 (33.09) -_83205 x"L 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 832 -1 4x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64,79) 83205-2xi: 2'-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205 f4x'L` = 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 28.4.24:152 2x'L' 21/2"-4 10" (254.0) 39800 - (177.03) 31169 (138.64) B3205 2314 x"L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 205-3 x'L t 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 -All Threaded Rod Cut To Length �� ```� . Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length '� }�, ' Material: Steel �»�� Maximum Temperature: 750°F (399°C) F ` µ d a o Finish: Plain. Contact B-Line for alternative finishes and materials. d w L N Order By: Part number, rod diameter and finish . a a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. A I K I-ig.y9 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"020,' 5'114"- 20 240 (1.07) 12 (5.44) ATR g J 1(2 i "x leticith 16 730 (3.24) 29 (13.15) ATR tit X129-- :tl -xlength 13 1350 (6.00) 53 (24.04) ATR eIB"x 120 - -. -I8 x n�: 11 2160 (9.60) 89 (40.37) 'ATR 3 X 120 . -$14"x len th s 10 3230 (14.37) 123 (55.79) ATR'!la"x 12 0 �18"'„x 9 4480 (19.93) 170 (77.11) ' ATR 1" v'1 20 99 "i length- 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. „ Pipe Hangers&Supports Revised4/28/2014 �� � * 236by E.T.N CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT 8 COMMUNITY DEVELOPMENT Permit#: FPS2022-00156 Date Issued: 12/12/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 1S1260000300 Jurisdiction: Tigard Site address: 9610 SW WASHINGTON SQUARE RD GO1 Project: Lush Subdivision: None Lot: None Project Description: Fire sprinklers. Add additional fire sprinkler heads as required for TI. Contractor: WYATT FIRE PROTECTION INC. Owner: PPR WASHINGTON SQUARE LLC 9095 SW BURNHAM BY MACERICH RET TIGARD, OR 97223 PO BOX 4085 SANTA MONICA, CA 90411 PHONE: 503-684-2928 PHONE: FAX: 503-684-9657 FEES Description Date Amount Specifics: Permit Fee-COM 12/09/2022 $123.72 12%State Surcharge-Building 12/09/2022 $14.85 Type of Use: COM Plan Review-Fire Life Safety-COM 12/09/2022 $49.49 Class of Work: ALT Type of Const: I I IA Info Process/Archiving-Sm$0.50(up to 12/09/2022 $7.00 Occupancy Grp: M Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: No Hazard: LT Density: 0.1 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $195.06 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules n , Issued By: �>--19eundtee Signature: /�(p�-c,t_k Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection.