Loading...
Report (2) IQ8 Series Microinverters INPUT DATA(DC) 108-60-2-US I88PLUS-72-2-US 10BM-72-2-US IO8A-72-2,US 108H-240-72-2-US 108H-208-72-2-US' Commonly used module pairings' W 235-350 235-440 260-460 295-500 320-540+ 295-500,- Module compatibility 60ce11/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 50 Max DC current'[module lsc] A 15 Overvoltage class DC port 11 DC port backfeed current mA 0 PV array configuration lx1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IACI 108-60-2-US I08PLUS-72-2-US 08M-72-2-US 108A-72-2-US IOBH-240-72-2-US 10811408-72-2-US Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal(L-L)voltage/range' V 240/211-264 208/183-250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit° 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency I. 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency 16 97 97 97 97.5 97 97 Night-time power consumption me/ 60 MECHANICAL OATH Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.381bs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <80 dBA Pollution degree PD3 Enclosure Class II double-Insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to - manufacturer's instructions. (1)The 1O8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https://Ilnk.enphase.com/module-compatibility(3)Maximum continuous input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8SE-DS-0001-01-EN-US-2021-10-19