Report Blower Door Test MEM
Affidavit Moffet Energy Modeling
CCB#
223372
916-342-0742
tyler@moffetco.com
Site Details
Builder Westwood Homes LLC
Street 11860 SW Walnut St
City/State/Zip Tigard, OR 97223
Conditioned Floor Area 2400 square feet
Conditioned Volume 25200 cubic feet
Source Plans
Test Conditions
Equipment Minneapolis Blower Door and DG 700 Manometer
Ring A
Weather Clouds
Test Results
Infiltration 1281.00 CFM @ 50 Pa
ACH (CFM * 60/Volume) 3.05 @ 50 Pa
I certify that these building leakage rates are accurate and determined using standard BPI testing protocols.
Company Name: Moffet Energy Modeling
Technician: Tyler Moffet
Technician Signature: Date: 9129/2022
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: NA
cie�//l Jurisdiction: t J�
of ( e
Site Address: / /'5 & f, Q- `I J L 5
Subdivision/Lot#: UM
f NA--
and/or U�•d l
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code N 1107.2)1
Signature: - Date: l°-"/
er/General Co actor/ uthori Agent
Print Name: U�
' ORSC Section N 1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps.
1:\Building\FormslRES-H ighEf ciencyL ightingAcknowledgement_022018
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
1, l� , am the general contractor or the owner-builder
at the following address:
Site Address: 1 f f 6 O t/ ,Q( i 6-r
City: I GV �/
Permit#: ,g,�a 1- ecOZg'
Subdivision/Lot#:� 1� v
and/or l
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: (0'-/7
ne o actor or Owner- ui
1.\Building\Form 1RES-M oistureContentAcknowl edgement_022018
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, '(AA_ W'!$.?ie, , am the general contractor or the owner-builder
at the following address:
Site Address: 11f lit)
(l v�� t ] /i ettk1/ 6�
City: �
Permit#: ^,61---2m& cozz(
Subdivision/Lot#: f' � a
tdr
and/or �•l/
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
rtzt The ground surface of the under-floor space is covered by a Class I vapor retarder or
other approved materials, with
11— Joints lapped 12 inches at seams and
IT Extending up the foundation walls 12 inches.
Signature: ririDate: IM-1 q`Z7j
e al Contract° o wn r- r