Report City of Tigard IIII Building Division RECEIVED 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 OCT" 2 5 2022. www.tigard-or.gov CITY OF TIGARD 3UILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12997 SW River Terrace Blvd City: Tigard Zip: 97007 Owner's Name: Todd Bischoff Date:7/19/2022 Contractor's Name: Nationwide Solar CCB #: 176918 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? V No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Ycs If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 2 Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures ® If"Yes", qualifies for other than Yes the prescriptive path. above ❑ No 1 I:Building/Forms/PhotoVoltaic-Checklist02-01-1 I docx Is the construction Type of material wood and does ® Yes the construction qualify If"Yes", qualifies for Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight V Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar I I No the prescriptive path. Code? ❑ Metal Single layer If roofing material is RoofingCheck thetype ❑ of wood yp of shingle/shake one of the three types material roofing material g checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof framing or blocking ❑ No the prescriptive path. to the roof directly? 2 liBuilding/Forms/Photovoltaic-Checklist02-0I-11.docx 0 Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes", qualifies for fastener? 0 the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the ® If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 IlBuilding/Forms/PhotoVohaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: HYUNDAI SOLAR (N)17-HYUNDAI SOLAR HIN-S365XG(BK)(365W)MODULES Model Number: (N)17-ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS Listing Agency: UL-IEC 4 I:1Building/Forms/PhotoVoltaic-Checkl ist02-01-I I docx 11 Oregon Solar Installation Specialty Code ' Checklist for Prescriptive Photovoltaic Installations in az> accordance with Section 3111.5.3 Department of Consumer and Business Services Building Codes Division 1535 Edgewater NW, Salem,OregonRECE IV ED Mailing address:P.O.Box 14470,Salem,OR 97309-0404 Phone: 503-378-4133•Fax:503-378-2322 Web:bcd.oregon.gov OCT 2 5 2027 PROPERTY OWNER INFORMATION CITY Oh I i(UAH17- Property owner name:Todd Bischoff 7lJ1LDING DIVISION Installation address:12997 SW River Terrace Blvd City: Beaverton State: OR ZIP: 97007 Structure on which modules are to be installed:Residence, Roof Mounted Day phone: ( )971-770-7937 Evening phone: ( ) Email address:info@3bischoff.com Contractor:Nationwide Solar CCB#:176918 Day phone: ( 800 )908 8992 ext 222 Evening phone: ( 800 )908 8992 ext 222 Email address:fangobung@mynationwidesolar.com SITE PLAN • Attach a simple site plan showing the location of the PV system in relation to buildings, structures,property lines,and,as applicable,flood hazard areas. • System must be shown in sufficient detail to assess whether the requirements of Section 3111.4.8 or one of the exceptions have been met. • The site plan must be on 8.5-inch x 11-inch or larger paper. STRUCTURAL INFORMATION All structures: • Is this conventional light framed wood construction? Yes 0 No ❑ (check one) • Does the structure have pre-engineered trusses? Yes 0 No ❑ (check one) OR • Does structure have roof framing members spaced at 24 inches on center maximum? Yes❑ No ❑ (check one) • Is the weight of the PV modules and racking less than 4.5 pounds per square foot? Yes ❑ No ❑ (check one) • Is the roofing material metal, single layer wood shingle,or not more than two layers of composition shingle? Yes ❑ No ❑ (check one) Myna rC&S N 440-4910(9/15/COM) STRUCTURAL INFORMATION (continued) Standing seam metal roofs: • Is the metal gauge 26 or heavier? Yes ❑ No ❑ (cheek one) • Clamp design:Are clamps designed to withstand uplift of at least 115 pounds for clamps spaced at 60 inches on center or less or at least 75 pounds for clamps spaced at 48 inches on center or less? Yes❑ No❑ (check one) • Is the spacing of the clamps as measured along the seam less than or equal to 24 inches on center? Yes❑ No ❑ (check one) • Is the roofing panel width 18 inches or less? Yes ❑ No ❑ (check one) • Will the roofing panel attachments be at least#10 screws at 24 inches on center? Yes ❑ No ❑ (check one) • Will the roofing panels be installed over minimum '/2-inch nominal wood structural panels attached to framing with 8d nails at six inches on center at panel edges and 12 inches on center field nailing? Yes❑ No D (check one) If no, on any of these requirements, the project may not be submitted using the prescriptive path. ROOF DESIGN AND ATTACHMENT • Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV system racking attachment. • System must be shown in sufficient detail to assess whether the requirements of Section 3111.5.3 have been met. • The structural plan must be on 8.5-inch x 11-inch or larger paper. WIND DESIGN • Does the project site exceed 95 mph in exposure C or 105 mph in exposures A or B? Yes❑ No ❑■ (check one) If yes, the project may not be submitted using the prescriptive path. • Is the module height less than 18 inches above the roof in accordance with section 3111.5.3? Yes No ❑ (check one) PV MODULES Manufacturer: HYUNDAI SOLAR Model number: (N)17-HYUNDAI SOLAR HIN-S365XG(BK)(365W)MODULES(N)17-ENPHASE IO7PLUS-72-2-US MICRO-INVERTERS Listing agency: UL-IEC Fabian Angobung 10/20/2022 Applicant name(please print) nt signature Date 440-4910(9/I5/COM)