2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12997 SW River Terrace Blvd
City: Tigard Zip: 97007
Owner's Name: Todd Bischoff Date:7/19/2022
Contractor's Name: Nationwide Solar CCB #: 176918
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? V No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure Ycs If"Yes", qualifies for
"C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes 2 Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures ® If"Yes", qualifies for
other than
Yes the prescriptive path.
above
❑ No
1
I:Building/Forms/PhotoVoltaic-Checklist02-01-1 I docx
Is the construction
Type of material wood and does ® Yes
the construction qualify If"Yes", qualifies for
Construction as "conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ® Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Is the combined weight V Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar I I No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
RoofingCheck thetype ❑ of wood
yp of shingle/shake one of the three types
material roofing material g checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly
If"Yes", qualifies for
the solar assembly connected to roof
framing or blocking ❑ No the prescriptive path.
to the roof
directly?
2
liBuilding/Forms/Photovoltaic-Checklist02-0I-11.docx
0 Yes If"Yes", qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches,qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of Yes If"Yes", qualifies for
fastener? 0 the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the ® If"Yes", qualifies for
solar modules module to the roof Yes the prescriptive path.
surface. ❑ No
3
IlBuilding/Forms/PhotoVohaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: HYUNDAI SOLAR
(N)17-HYUNDAI SOLAR HIN-S365XG(BK)(365W)MODULES
Model Number: (N)17-ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS
Listing Agency: UL-IEC
4
I:1Building/Forms/PhotoVoltaic-Checkl ist02-01-I I docx
11 Oregon Solar Installation Specialty Code
' Checklist for Prescriptive Photovoltaic Installations in
az> accordance with Section 3111.5.3
Department of Consumer and Business Services
Building Codes Division
1535 Edgewater NW, Salem,OregonRECE IV
ED
Mailing address:P.O.Box 14470,Salem,OR 97309-0404
Phone: 503-378-4133•Fax:503-378-2322
Web:bcd.oregon.gov OCT 2 5 2027
PROPERTY OWNER INFORMATION CITY Oh I i(UAH17-
Property owner name:Todd Bischoff 7lJ1LDING DIVISION
Installation address:12997 SW River Terrace Blvd
City: Beaverton State: OR ZIP: 97007
Structure on which modules are to be installed:Residence, Roof Mounted
Day phone: ( )971-770-7937 Evening phone: ( )
Email address:info@3bischoff.com
Contractor:Nationwide Solar CCB#:176918
Day phone: ( 800 )908 8992 ext 222 Evening phone: ( 800 )908 8992 ext 222
Email address:fangobung@mynationwidesolar.com
SITE PLAN
• Attach a simple site plan showing the location of the PV system in relation to buildings,
structures,property lines,and,as applicable,flood hazard areas.
• System must be shown in sufficient detail to assess whether the requirements of Section 3111.4.8
or one of the exceptions have been met.
• The site plan must be on 8.5-inch x 11-inch or larger paper.
STRUCTURAL INFORMATION
All structures:
• Is this conventional light framed wood construction?
Yes 0 No ❑ (check one)
• Does the structure have pre-engineered trusses?
Yes 0 No ❑ (check one)
OR
• Does structure have roof framing members spaced at 24 inches on center maximum?
Yes❑ No ❑ (check one)
• Is the weight of the PV modules and racking less than 4.5 pounds per square foot?
Yes ❑ No ❑ (check one)
• Is the roofing material metal, single layer wood shingle,or not more than two layers of
composition shingle?
Yes ❑ No ❑ (check one)
Myna
rC&S N
440-4910(9/15/COM)
STRUCTURAL INFORMATION (continued)
Standing seam metal roofs:
• Is the metal gauge 26 or heavier?
Yes ❑ No ❑ (cheek one)
• Clamp design:Are clamps designed to withstand uplift of at least 115 pounds for clamps spaced at
60 inches on center or less or at least 75 pounds for clamps spaced at 48 inches on center or less?
Yes❑ No❑ (check one)
• Is the spacing of the clamps as measured along the seam less than or equal to 24 inches on center?
Yes❑ No ❑ (check one)
• Is the roofing panel width 18 inches or less?
Yes ❑ No ❑ (check one)
• Will the roofing panel attachments be at least#10 screws at 24 inches on center?
Yes ❑ No ❑ (check one)
• Will the roofing panels be installed over minimum '/2-inch nominal wood structural panels
attached to framing with 8d nails at six inches on center at panel edges and 12 inches on center
field nailing?
Yes❑ No D (check one)
If no, on any of these requirements, the project may not be submitted using the prescriptive path.
ROOF DESIGN AND ATTACHMENT
• Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV
system racking attachment.
• System must be shown in sufficient detail to assess whether the requirements of Section 3111.5.3
have been met.
• The structural plan must be on 8.5-inch x 11-inch or larger paper.
WIND DESIGN
• Does the project site exceed 95 mph in exposure C or 105 mph in exposures A or B?
Yes❑ No ❑■ (check one) If yes, the project may not be submitted using the prescriptive path.
• Is the module height less than 18 inches above the roof in accordance with section 3111.5.3?
Yes No ❑ (check one)
PV MODULES
Manufacturer: HYUNDAI SOLAR
Model number: (N)17-HYUNDAI SOLAR HIN-S365XG(BK)(365W)MODULES(N)17-ENPHASE IO7PLUS-72-2-US MICRO-INVERTERS
Listing agency: UL-IEC
Fabian Angobung 10/20/2022
Applicant name(please print) nt signature Date