Report Y
II/ City of Tigard
Building Division
- 13125 SW Hall Blvd,Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
T I G A R D Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: i3 Z 1 7 so l -z_e_i �, \ - Wc,,
City: pip: °l `7 2-2-`-1
Owner's Name: i4, ,L, - S m_L Date: L\ Z7-17—'4---
Contractor's Name: Sin e SaL LI 6 CCB #: L ta9.1 cf3-1
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure `es If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf ess?
dwelling/single/two- If"Yes", qualifies for
family townhomes Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
❑ Yes the prescriptive path.
above
❑ No
1
I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
Is the construction
Type of material wood and does Yes If"Yes", qualifies for
the construction qualify
Construction as"conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or les .
Pre-engineered trusses. Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. Yes
❑ the prescriptive path.
❑ No
Is the combined weight 04es
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation yes
layout in accordance If"Yes", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
mgle layer If roofing material is
Roofing Check the type of of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑ of composition
shingle.
Is the roof mounted 0 yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof ❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:Building/Forms/PhotoVottaic-Checklist02-01-11.docx
Yes „
Is the gauge 26 or less? If Yes , qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
7 No
Attachment of
roof mounted If the spacing falls
solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60
dlrectl to inches inches, qualifies for the
Y Maximum 60 inches prescriptive path.
standing seam
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of Yes If"Yes", qualifies for
fastener? ❑ the prescriptive path.
❑ No
Is the roof decking of
WSP min. 1/2" thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 ' ches?
Height of the from the top of the Yes If"Yes", qualifies for
solar modules module to the roof the prescriptive path.
surface. ❑ No
3
L'Building/Forms/PhotoVoltaic-Checklist02-o1-11.docx
• Y
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:
Model Number: y alb' Ri riz Pj�v(L
Listing Agency: OL
4
1:Building/Fotms/Photo V oltaic-Checklist02-01-11.docx