TRANSMITTAL LETTER
TO: CITY OF TIGARD DATE: 06/28/22
ATTN: BRANDON TAGGART
13125 SW HALL BLVD.
TIGARD,OR 97223
503-718-2436
RE: TESLA@10069 SW Cascade Blvd,
PROJECT NO. 210712
SENT VIA: NEXT DAY AIR
ENCLOSED PLEASE FIND THE FOLLOWING:
QUANTITY DESCRIPTION COMMENTS
1 APPLICATION-MEP APPLICATIONS
2 COMPLETE PLANS S/S CUT SHEETS
INCLUDED
2 COMCHECKS
Remarks: Please find materials enclosed for your review. If you have any questions,please contact me
at 336-830-1111 or jgodsey@arcv.com.
Arc Vision Inc.
Joanie Godsey
jgodsey@arcv.com
CC: File, J:\Clients\
1950 Craig Road,Suite 300•St. Louis, MO 63146• Phone (314) 415-2400• Fax (314) 415-2300
A
COMcheck Software Version COMcheckWeb
1141 II Interior Lighting Compliance Certificate
Project Information
Energy Code: 90.1 (2019) Standard
Project Title: Tesla Center-Tigard OR
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
10069 Southwest Cascade Ave
Tigard,Oregon 97223
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts /ft2 Watts
1-Showroom(Common Space Types:Sales Area) 2304 1.05 2419
2-Offices(Common Space Types:Office-Enclosed >250 sq ft) 1334 0.66 880
3-Conference Room (Common Space 110 0.97 107
Types:Conference/Meeting/Multipurpose)
4-Customer Showroom Lounge(Common Space Types:Sales Area) 500 1.05 525
5-Restroom(Common Space Types:Restrooms) 74 0.63 47
6-IT Room (Common Space Types:Computer Room) 50 0.94 47
7-Utility Room(Common Space Types:Electrical/Mechanical) 127 0.43 55
8-Breakroom(Common Space Types:Lounge/Breakroom) 318 0.59 188
Total Allowed Watts= 4267
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Showroom (Common Space Types: Sales Area. 2304 sq.ft.)
LED: L164:Custom LED Strip: Other: 1 282 9 2482
Offices (Common Space Types: Office- Enclosed >250 sq ft. 1334 sa.ft.)
LED: L101: 2x4 LED Flat Panel:Other: 1 6 40 240
LED: L102:2x4 LED Flat Panel W/battery pa: Other: 1 2 40 80
LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 11 40 440
LED: L104:2x2 LED Flat Panel W/battery pa: LED Panel 40W: 1 3 40 120
conference Room (Common Space Types: Conference/Meeting/Multipurpose. 110 sq.ft.)
LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40
Customer Showroom Lounge (Common Space Types: Sales Area. 500 sq.ft.)
LED: L104:2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 4 40 160
LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 5 40 200
Restroom (Common Space Types: Restrooms. 74 sa.ft.)
LED: L141: 6" LED Downlight:Other: 1 1 25 25
LED: L142: 6"LED Downlight W/Battery Back:Other: 1 1 25 25
IT Room (Common Space Types: Computer Room. 50 sq.ft.)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 1 of 5
•
A B C D E
Fixture ID : Description / Lamp/ Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40
Utility Room (Common Space Types: Electrical/Mechanical. 127 sa.ft.)
LED: L151: LED Strip:Other: 1 1 32 32
LED: L152: LED Strip/battery Backup:Other: 1 1 32 32
Breakroom (Common pace Types Lounge/Breakroom 318 sa.ft.)
LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 4 40 160
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 2 40 80
Total Proposed Watts= 4236
Interior Lighting PASSES
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 90.1 (2019)Standard requirements in COMcheck Version COMcheckWeb and to comply
with any applicable mandatory requirements listed in the Inspection Checklist.
Robert L. Queathem-Engineer
Name-Title Signature Date
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 2 of 5
COMcheck Software Version COMcheckWeb
Inspection Checklist
Energy Code: 90.1 (2019) Standard
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
4.2.2, Plans,specifications,and/or ❑Complies
9.4.3, 9.7 calculations provide all information ❑Does Not
[PR4]i i with which compliance can be
I determined for the interior lighting ['Not Observable
Iand electrical systems and equipment ❑Not Applicable
and document where exceptions to
,the standard are claimed. Information
!provided should include interior
lighting power calculations,wattage of
'bulbs and ballasts,transformers and
!control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) ['Medium Impact(Tier 2) 37.Low Impact(Tier 3)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 3 of 5
•
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
9.4.1.1 Automatic control requirements ❑Complies
[EL1]2 prescribed in Table 9.6.1,for the ❑Does Not
appropriate space type,are installed.
Mandatory lighting controls(labeled ['Not Observable
as 'REQ')and optional choice controls ONot Applicable
(labeled as'ADDl'and 'ADD2')are
implemented.
9.4.1.1a Independent lighting controls installed ❑Complies
[EL2]2 per approved lighting plans and all :❑Does Not
manual controls readily accessible and ❑Not Observable
visible to occupants.
DNot Applicable
9.4.1.1b No lighting shall be automatically ❑Complies
[EL26]2 turned on-restriced to manual. ❑Does Not
❑Not Observable
ONot Applicable
9.4.1.ic <= 50%of general lighting power ❑Complies
[EL27]2 shall be allowed to be automatically ❑Does Not
turned on.
['Not Observable
ONot Applicable
9.4.1.1d 'Bilevel lighting control-<= 50%of ❑Complies
[EL28]2 general lighting controlled with one ❑Does Not
intermediate step between full off and
full on. ONot Observable
ONot Applicable
9.4.1.1eAutomatic daylight responsive ❑Complies
[EL29]2 controls for sidelighting >= 150 watts ❑Does Not
controlled by photocontrols.
[Not Observable
ONot Applicable
9.4.1.1f Automatic daylight responsive ❑Complies
[EL30]2 controls for toplighting >= 150 watts Does Not
controlled by photocontrols.
['Not Observable
ONot Applicable
9.4.1.1g Automatic partial OFF: lighting shall ❑Complies
[EL31)2 be reduced >=50%within 20 minutes ❑Does Not
of zero occupancy.
ONot Observable
ONot Applicable
9.4.1.1h Automatic full OFF: lighting shall be ❑Complies
[EL32]2 shut off within 20 minutes of zero ❑Does Not
occupancy.
DNot Observable
ONot Applicable
9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies
[EL33]2 shut off when scheduled to be ❑Does Not
unoccupied.
['Not Observable
ONot Applicable
9.4.1.3 Separate lighting control devices for ❑Complies
[EL4]1 ;specific uses installed per approved ❑Does Not
'lighting plans.
ONot Observable
ONot Applicable
9.6.2 'Additional interior lighting power ❑Complies
[EL8]1 allowed for special functions per the ❑Does Not
;approved lighting plans and is
automatically controlled and [Not Observable
separated from general lighting. ONot Applicable
Additional Comments/Assumptions:
1'High Impact(Tier 1) ' Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: TeslaCenter-TigardOR Report date: 06/15/22
Data filename: Page 4 of 5
t
Section
# Final Inspection Complies? Comments/Assumptions
&,Req.ID
8.7.1 Furnished as-built drawings for [(complies
[FI16]3 electric power systems within 30 days ElDoes Not
of system acceptance.
❑Not Observable
❑Not Applicable
8.7.2 Furnished O&M instructions for ,❑Complies
(FI17)3 systems and equipment to the ElDoes Not
building owner or designated Not Observable
representative.
❑Not Applicable
9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[FI18]1 j lighting power is consistent with what ❑Does Not
is shown on the approved lighting [(Not Observable
(plans,demonstrating proposed watts
are less than or equal to allowed ❑Not Applicable
'watts.
9.4.4 iAt least 75%of all permanently ❑Complies
(FI20)1 I installed lighting fixtures in dwelling ❑Does Not
units have>= 55 Im/W efficacy or a
l>=45 lm/W total luminaire efficacy. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier--11 Medium Impact(Tier 2) 3'I Low Impact(Tier 3)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 5 of 5
' 1 COMcheck Software Version COMcheckWeb
\..j. Interior Lighting Compliance Certificate
Project Information
Energy Code: 90.1 (2019) Standard
Project Title: Tesla Center-Tigard OR
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
10069 Southwest Cascade Ave
Tigard, Oregon 97223
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts /ft2 Watts
1-Showroom(Common Space Types:Sales Area) 2304 1.05 2419
2-Offices(Common Space Types:Office-Enclosed >250 sq ft) 1334 0.66 880
3-Conference Room (Common Space 110 0.97 107
Types:Conference/Meeting/Multipurpose)
4-Customer Showroom Lounge(Common Space Types:Sales Area) 500 1.05 525
5-Restroom(Common Space Types:Restrooms) 74 0.63 47
6-IT Room(Common Space Types:Computer Room) 50 0.94 47
7-Utility Room(Common Space Types:Electrical/Mechanical) 127 0.43 55
8-Breakroom (Common Space Types:Lounge/Breakroom) 318 0.59 188
Total Allowed Watts= 4267
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp/ Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Showroom (Common Space Types: Sales Area. 2304 sq.ft.)
LED: L164:Custom LED Strip:Other: 1 282 9 2482
Offices (Common Space Types: Office-Enclosed >250 sq ft. 1334 sq.ft.)
LED:L101:2x4 LED Flat Panel:Other: 1 6 40 240
LED: L102: 2x4 LED Flat Panel W/battery pa: Other: 1 2 40 80
LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 11 40 440
LED: L104: 2x2 LED Flat Panel W/battery pa: LED Panel 40W: 1 3 40 120
Conference Room (Common Space Types: Conference/Meeting/Multipurpose. 110 sq.ft.)
LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40
Customer Showroom Lounge (Common Space Types: Sales Area. 500 sq.ft.)
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 4 40 160
LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 5 40 200
Restroom (Common Space Types: Restrooms. 74 sq.ft.)
LED: L141: 6" LED Downlight:Other: 1 1 25 25
LED: L142: 6" LED Downlight W/Battery Back:Other: 1 1 25 25
IT Room (Common Space Types: Computer Room. 50 sa.ft.)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 1 of 5
r A B C D E
Fixture ID : Description / Lamp/ Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40
Utility Room (Common Space Types: Electrical/Mechanical. 127 sq.ft.)
LED: L151: LED Strip: Other: 1 1 32 32
LED: L152: LED Strip/battery Backup:Other: 1 1 32 32
Breakroom (Common a ce_Ty :pes Lounge/Breakroom 318 sa.ft.
)
LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 4 40 160
LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 2 40 80
Total Proposed Watts= 4236
Interior Lighting PASSES
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 90.1 (2019)Standard requirements in COMcheck Version COMcheckWeb and to comply
with any applicable mandatory requirements listed in the Inspection Checklist.
Robert L. Queathem-Engineer
Name-Title Signature Date
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 2 of 5
COMcheck Software Version COMcheckWeb
Inspection Checklist
Energy Code: 90.1 (2019) Standard dard
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plan Review Complies? Comments/Assumptions
&Req.ID
4.2.2, Plans, specifications, and/or ,DComplies
9.4.3, 9.7 calculations provide all information ❑Does Not
[PR4J1 with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment :❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 IMedium Impact(Tier 2) 1 3 I Low Impact(Tier 3)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 3 of 5
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
9.4.1.1 Automatic control requirements ❑Complies
[ELl]2 prescribed in Table 9.6.1,for the ❑Does Not
appropriate space type, are installed.
Mandatory lighting controls(labeled ❑Not Observable
as'REQ')and optional choice controls ONot Applicable
(labeled as'ADD1'and 'ADD2') are
implemented.
9.4.1.1a Independent lighting controls installed ['Complies
[EL2]2 per approved lighting plans and all ❑Does Not
manual controls readily accessible and [Not Observable
visible to occupants. ONot Applicable
9.4.1.1b No lighting shall be automatically ❑Complies
[EL26]2 turned on-restriced to manual. Does Not
[Not Observable
❑Not Applicable
9.4.1 lc f<=50%of general lighting power ❑Complies
[EL27]2 shall be allowed to be automatically ❑Does Not
turned on.
❑Not Observable
❑Not Applicable
9.4.1.1d Bilevel lighting control-<=50%of ❑Complies
[EL28]2 general lighting controlled with one ODoes Not
intermediate step between full off and
full on. ['Not Observable
ONot Applicable
9.4.1.1e Automatic daylight responsive ❑Complies
[EL29]2 controls for sidelighting >= 150 watts ❑Does Not
controlled by photocontrols.
['Not Observable
O Not Applicable
9.4.1.1f Automatic daylight responsive OComplies
[EL30]2 controls for toplighting >= 150 watts ❑Does Not
controlled by photocontrols. ONot Observable
ONot Applicable
9.4.1.1g Automatic partial OFF: lighting shall ❑Complies
[EL31]2 be reduced >= 50%within 20 minutes❑Does Not
of zero occupancy.
ONot Observable
ONot Applicable
9.4.1.1h Automatic full OFF: lighting shall be ❑Complies
[EL32]2 shut off within 20 minutes of zero ❑Does Not
occupancy.
ONot Observable
O Not Applicable
9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies
[EL33]2 shut off when scheduled to be ❑Does Not
unoccupied.
['Not Observable
O Not Applicable
9.4.1.3 Separate lighting control devices for ❑Complies
[EL4]1 :specific uses installed per approved ❑Does Not
lighting plans. ['Not Observable
ONot Applicable
9.6.2 Additional interior lighting power ❑Complies
[EL8]1 iallowed for special functions per the ❑Does Not
approved lighting plans and is ['Not Observable
!automatically controlled and
(separated from general lighting. ❑Not Applicable
Additional Comments/Assumptions:
nHigh Impact(Tier 1) � Medium Impact(Tier 2) Low Impact(Tier 3)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 4 of 5
Section
Final Inspection Complies? Comments/Assumptions
& Req.ID
8.7.1 Furnished as-built drawings for ❑Complies
[FI16]3 electric power systems within 30 days ❑Does Not
of system acceptance. ;❑Not Observable
❑Not Applicable
8.7.2 Furnished O&M instructions for ❑Complies
[FI17]3 systems and equipment to the DDoes Not
building owner or designated ❑Not Observable
representative.
❑Not Applicable
9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
!is shown on the approved lighting
plans,demonstrating proposed watts [Not Observable
!are less than or equal to allowed `❑Not Applicable
watts.
9.4.4 lAt least 75%of all permanently ❑Complies
[FI20]1 installed lighting fixtures in dwelling ❑Does Not
!units have >= 55 Im/W efficacy or a ❑Not Observable
j>=45 Im/W total luminaire efficacy.
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier i) F Medium Impact(Tier 2) 3' Low Impact(Tier 3)
Project Title: Tesla Center-Tigard OR Report date: 06/15/22
Data filename: Page 5 of 5