Loading...
Report ELC. 2.022- O L. qq i 0069 CasCAde. SAINT LOUIS ORLANDO A R a 'S I 0 N DALLAS LAS VEGAS INCORPOR ATED SEATTLE ARCHITECTURE • ENGINEERING • STORE PLANNING TRANSMITTAL LETTER TO: CITY OF TIGARD DATE: 06/28/22 ATTN: BRANDON TAGGART 13125 SW HALL BLVD. TIGARD,OR 97223 503-718-2436 RE: TESLA@10069 SW Cascade Blvd, PROJECT NO. 210712 SENT VIA: NEXT DAY AIR ENCLOSED PLEASE FIND THE FOLLOWING: QUANTITY DESCRIPTION COMMENTS 1 APPLICATION-MEP APPLICATIONS 2 COMPLETE PLANS S/S CUT SHEETS INCLUDED 2 COMCHECKS Remarks: Please find materials enclosed for your review. If you have any questions,please contact me at 336-830-1111 or jgodsey@arcv.com. Arc Vision Inc. Joanie Godsey jgodsey@arcv.com CC: File, J:\Clients\ 1950 Craig Road,Suite 300•St. Louis, MO 63146• Phone (314) 415-2400• Fax (314) 415-2300 A COMcheck Software Version COMcheckWeb 1141 II Interior Lighting Compliance Certificate Project Information Energy Code: 90.1 (2019) Standard Project Title: Tesla Center-Tigard OR Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 10069 Southwest Cascade Ave Tigard,Oregon 97223 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts /ft2 Watts 1-Showroom(Common Space Types:Sales Area) 2304 1.05 2419 2-Offices(Common Space Types:Office-Enclosed >250 sq ft) 1334 0.66 880 3-Conference Room (Common Space 110 0.97 107 Types:Conference/Meeting/Multipurpose) 4-Customer Showroom Lounge(Common Space Types:Sales Area) 500 1.05 525 5-Restroom(Common Space Types:Restrooms) 74 0.63 47 6-IT Room (Common Space Types:Computer Room) 50 0.94 47 7-Utility Room(Common Space Types:Electrical/Mechanical) 127 0.43 55 8-Breakroom(Common Space Types:Lounge/Breakroom) 318 0.59 188 Total Allowed Watts= 4267 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Showroom (Common Space Types: Sales Area. 2304 sq.ft.) LED: L164:Custom LED Strip: Other: 1 282 9 2482 Offices (Common Space Types: Office- Enclosed >250 sq ft. 1334 sa.ft.) LED: L101: 2x4 LED Flat Panel:Other: 1 6 40 240 LED: L102:2x4 LED Flat Panel W/battery pa: Other: 1 2 40 80 LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 11 40 440 LED: L104:2x2 LED Flat Panel W/battery pa: LED Panel 40W: 1 3 40 120 conference Room (Common Space Types: Conference/Meeting/Multipurpose. 110 sq.ft.) LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40 LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40 Customer Showroom Lounge (Common Space Types: Sales Area. 500 sq.ft.) LED: L104:2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 4 40 160 LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 5 40 200 Restroom (Common Space Types: Restrooms. 74 sa.ft.) LED: L141: 6" LED Downlight:Other: 1 1 25 25 LED: L142: 6"LED Downlight W/Battery Back:Other: 1 1 25 25 IT Room (Common Space Types: Computer Room. 50 sq.ft.) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 1 of 5 • A B C D E Fixture ID : Description / Lamp/ Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40 LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40 Utility Room (Common Space Types: Electrical/Mechanical. 127 sa.ft.) LED: L151: LED Strip:Other: 1 1 32 32 LED: L152: LED Strip/battery Backup:Other: 1 1 32 32 Breakroom (Common pace Types Lounge/Breakroom 318 sa.ft.) LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 4 40 160 LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 2 40 80 Total Proposed Watts= 4236 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2019)Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Robert L. Queathem-Engineer Name-Title Signature Date Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 2 of 5 COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 90.1 (2019) Standard Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID 4.2.2, Plans,specifications,and/or ❑Complies 9.4.3, 9.7 calculations provide all information ❑Does Not [PR4]i i with which compliance can be I determined for the interior lighting ['Not Observable Iand electrical systems and equipment ❑Not Applicable and document where exceptions to ,the standard are claimed. Information !provided should include interior lighting power calculations,wattage of 'bulbs and ballasts,transformers and !control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) ['Medium Impact(Tier 2) 37.Low Impact(Tier 3) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 3 of 5 • Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 9.4.1.1 Automatic control requirements ❑Complies [EL1]2 prescribed in Table 9.6.1,for the ❑Does Not appropriate space type,are installed. Mandatory lighting controls(labeled ['Not Observable as 'REQ')and optional choice controls ONot Applicable (labeled as'ADDl'and 'ADD2')are implemented. 9.4.1.1a Independent lighting controls installed ❑Complies [EL2]2 per approved lighting plans and all :❑Does Not manual controls readily accessible and ❑Not Observable visible to occupants. DNot Applicable 9.4.1.1b No lighting shall be automatically ❑Complies [EL26]2 turned on-restriced to manual. ❑Does Not ❑Not Observable ONot Applicable 9.4.1.ic <= 50%of general lighting power ❑Complies [EL27]2 shall be allowed to be automatically ❑Does Not turned on. ['Not Observable ONot Applicable 9.4.1.1d 'Bilevel lighting control-<= 50%of ❑Complies [EL28]2 general lighting controlled with one ❑Does Not intermediate step between full off and full on. ONot Observable ONot Applicable 9.4.1.1eAutomatic daylight responsive ❑Complies [EL29]2 controls for sidelighting >= 150 watts ❑Does Not controlled by photocontrols. [Not Observable ONot Applicable 9.4.1.1f Automatic daylight responsive ❑Complies [EL30]2 controls for toplighting >= 150 watts Does Not controlled by photocontrols. ['Not Observable ONot Applicable 9.4.1.1g Automatic partial OFF: lighting shall ❑Complies [EL31)2 be reduced >=50%within 20 minutes ❑Does Not of zero occupancy. ONot Observable ONot Applicable 9.4.1.1h Automatic full OFF: lighting shall be ❑Complies [EL32]2 shut off within 20 minutes of zero ❑Does Not occupancy. DNot Observable ONot Applicable 9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies [EL33]2 shut off when scheduled to be ❑Does Not unoccupied. ['Not Observable ONot Applicable 9.4.1.3 Separate lighting control devices for ❑Complies [EL4]1 ;specific uses installed per approved ❑Does Not 'lighting plans. ONot Observable ONot Applicable 9.6.2 'Additional interior lighting power ❑Complies [EL8]1 allowed for special functions per the ❑Does Not ;approved lighting plans and is automatically controlled and [Not Observable separated from general lighting. ONot Applicable Additional Comments/Assumptions: 1'High Impact(Tier 1) ' Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: TeslaCenter-TigardOR Report date: 06/15/22 Data filename: Page 4 of 5 t Section # Final Inspection Complies? Comments/Assumptions &,Req.ID 8.7.1 Furnished as-built drawings for [(complies [FI16]3 electric power systems within 30 days ElDoes Not of system acceptance. ❑Not Observable ❑Not Applicable 8.7.2 Furnished O&M instructions for ,❑Complies (FI17)3 systems and equipment to the ElDoes Not building owner or designated Not Observable representative. ❑Not Applicable 9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 j lighting power is consistent with what ❑Does Not is shown on the approved lighting [(Not Observable (plans,demonstrating proposed watts are less than or equal to allowed ❑Not Applicable 'watts. 9.4.4 iAt least 75%of all permanently ❑Complies (FI20)1 I installed lighting fixtures in dwelling ❑Does Not units have>= 55 Im/W efficacy or a l>=45 lm/W total luminaire efficacy. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier--11 Medium Impact(Tier 2) 3'I Low Impact(Tier 3) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 5 of 5 ' 1 COMcheck Software Version COMcheckWeb \..j. Interior Lighting Compliance Certificate Project Information Energy Code: 90.1 (2019) Standard Project Title: Tesla Center-Tigard OR Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 10069 Southwest Cascade Ave Tigard, Oregon 97223 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts /ft2 Watts 1-Showroom(Common Space Types:Sales Area) 2304 1.05 2419 2-Offices(Common Space Types:Office-Enclosed >250 sq ft) 1334 0.66 880 3-Conference Room (Common Space 110 0.97 107 Types:Conference/Meeting/Multipurpose) 4-Customer Showroom Lounge(Common Space Types:Sales Area) 500 1.05 525 5-Restroom(Common Space Types:Restrooms) 74 0.63 47 6-IT Room(Common Space Types:Computer Room) 50 0.94 47 7-Utility Room(Common Space Types:Electrical/Mechanical) 127 0.43 55 8-Breakroom (Common Space Types:Lounge/Breakroom) 318 0.59 188 Total Allowed Watts= 4267 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp/ Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Showroom (Common Space Types: Sales Area. 2304 sq.ft.) LED: L164:Custom LED Strip:Other: 1 282 9 2482 Offices (Common Space Types: Office-Enclosed >250 sq ft. 1334 sq.ft.) LED:L101:2x4 LED Flat Panel:Other: 1 6 40 240 LED: L102: 2x4 LED Flat Panel W/battery pa: Other: 1 2 40 80 LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 11 40 440 LED: L104: 2x2 LED Flat Panel W/battery pa: LED Panel 40W: 1 3 40 120 Conference Room (Common Space Types: Conference/Meeting/Multipurpose. 110 sq.ft.) LED: L103: 2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40 LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40 Customer Showroom Lounge (Common Space Types: Sales Area. 500 sq.ft.) LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 4 40 160 LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 5 40 200 Restroom (Common Space Types: Restrooms. 74 sq.ft.) LED: L141: 6" LED Downlight:Other: 1 1 25 25 LED: L142: 6" LED Downlight W/Battery Back:Other: 1 1 25 25 IT Room (Common Space Types: Computer Room. 50 sa.ft.) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 1 of 5 r A B C D E Fixture ID : Description / Lamp/ Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 1 40 40 LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 1 40 40 Utility Room (Common Space Types: Electrical/Mechanical. 127 sq.ft.) LED: L151: LED Strip: Other: 1 1 32 32 LED: L152: LED Strip/battery Backup:Other: 1 1 32 32 Breakroom (Common a ce_Ty :pes Lounge/Breakroom 318 sa.ft. ) LED: L103:2x2 LED Flat Panel: LED Panel 40W: 1 4 40 160 LED: L104: 2x2 LED Flat Panel W/battery Ba: LED Panel 40W: 1 2 40 80 Total Proposed Watts= 4236 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2019)Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Robert L. Queathem-Engineer Name-Title Signature Date Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 2 of 5 COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 90.1 (2019) Standard dard Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions &Req.ID 4.2.2, Plans, specifications, and/or ,DComplies 9.4.3, 9.7 calculations provide all information ❑Does Not [PR4J1 with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment :❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 IMedium Impact(Tier 2) 1 3 I Low Impact(Tier 3) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 3 of 5 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 9.4.1.1 Automatic control requirements ❑Complies [ELl]2 prescribed in Table 9.6.1,for the ❑Does Not appropriate space type, are installed. Mandatory lighting controls(labeled ❑Not Observable as'REQ')and optional choice controls ONot Applicable (labeled as'ADD1'and 'ADD2') are implemented. 9.4.1.1a Independent lighting controls installed ['Complies [EL2]2 per approved lighting plans and all ❑Does Not manual controls readily accessible and [Not Observable visible to occupants. ONot Applicable 9.4.1.1b No lighting shall be automatically ❑Complies [EL26]2 turned on-restriced to manual. Does Not [Not Observable ❑Not Applicable 9.4.1 lc f<=50%of general lighting power ❑Complies [EL27]2 shall be allowed to be automatically ❑Does Not turned on. ❑Not Observable ❑Not Applicable 9.4.1.1d Bilevel lighting control-<=50%of ❑Complies [EL28]2 general lighting controlled with one ODoes Not intermediate step between full off and full on. ['Not Observable ONot Applicable 9.4.1.1e Automatic daylight responsive ❑Complies [EL29]2 controls for sidelighting >= 150 watts ❑Does Not controlled by photocontrols. ['Not Observable O Not Applicable 9.4.1.1f Automatic daylight responsive OComplies [EL30]2 controls for toplighting >= 150 watts ❑Does Not controlled by photocontrols. ONot Observable ONot Applicable 9.4.1.1g Automatic partial OFF: lighting shall ❑Complies [EL31]2 be reduced >= 50%within 20 minutes❑Does Not of zero occupancy. ONot Observable ONot Applicable 9.4.1.1h Automatic full OFF: lighting shall be ❑Complies [EL32]2 shut off within 20 minutes of zero ❑Does Not occupancy. ONot Observable O Not Applicable 9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies [EL33]2 shut off when scheduled to be ❑Does Not unoccupied. ['Not Observable O Not Applicable 9.4.1.3 Separate lighting control devices for ❑Complies [EL4]1 :specific uses installed per approved ❑Does Not lighting plans. ['Not Observable ONot Applicable 9.6.2 Additional interior lighting power ❑Complies [EL8]1 iallowed for special functions per the ❑Does Not approved lighting plans and is ['Not Observable !automatically controlled and (separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: nHigh Impact(Tier 1) � Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 4 of 5 Section Final Inspection Complies? Comments/Assumptions & Req.ID 8.7.1 Furnished as-built drawings for ❑Complies [FI16]3 electric power systems within 30 days ❑Does Not of system acceptance. ;❑Not Observable ❑Not Applicable 8.7.2 Furnished O&M instructions for ❑Complies [FI17]3 systems and equipment to the DDoes Not building owner or designated ❑Not Observable representative. ❑Not Applicable 9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not !is shown on the approved lighting plans,demonstrating proposed watts [Not Observable !are less than or equal to allowed `❑Not Applicable watts. 9.4.4 lAt least 75%of all permanently ❑Complies [FI20]1 installed lighting fixtures in dwelling ❑Does Not !units have >= 55 Im/W efficacy or a ❑Not Observable j>=45 Im/W total luminaire efficacy. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier i) F Medium Impact(Tier 2) 3' Low Impact(Tier 3) Project Title: Tesla Center-Tigard OR Report date: 06/15/22 Data filename: Page 5 of 5