Loading...
Report Cam. \ Ic y 'SIEMENS C NFPA 72 REPORT Ietrki.4117 fpr Gf¢. 1 4J Z 072 .• en, q SYSTEM RECORD OF COMPLETION - ADDENDUM %;7171 Sits System Name: Washington Square Mall Panel Name: Washington Square Mall Date of Acceptance: 11 Nov 2022 Contract Info: OR1 P-FIS-WSQM LEVI'S Supplemental Pages Attached: Yes 1. PROPERTY INFORMATION Name of property: Washington Square Mall Levi's Address: 9677 SW Washington Square RD C05 Tigard,Or 97223 Description of property: Name of property representative: Washington Square Mall Address: 9585 SW Washington Square RD Tigard,Or 97223 Phone: None Fax: None E-mail: None 2. INSTALLATION,SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor: SIEMENS Address: N/A Phone: 971-207-1900 Fax: 971-207-1901 E-mail: NA Service organization: Address:_, Phone:_ Fax:_ E-mail: Testing organization: SIEMENS Address: 9755 SW Barnes Rd,Suite 205, Portland,OR 97225 Phone: 503 2071900 Fax: 503 207 1901 E-mail: NA Effective date for test and inspection contract: Monitoring organization: Address: Phone:_ Fax:_ E-mail: Account number:_ Phone line 1:_ Phone line 2: Means of transmission: Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: IN FACP ROOM/ON USB STICK 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: Modification Permit number: SEE PERMIT NFPA 72 edition: NA 4.1 Control Unit Manufacturer: Siemens Model number: XLS Location: Security Office 4.2 Software and Firmware Firmware revision number: ZEUS 14.04 4.3 Alarm Verification E3 This system does not incorporate alarm verification. Number of devices subject to alarm verification: NA Alarm verification set for NA seconds • SIEMENS NFPA 72 REPORT 1,,r,„47-for(fe 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 Control panel amps: 20 Overcurrent protection: Type: Breaker Amps: 20 Branch circuit disconnecting means location: In Electrical RM Number: 5.1.2 Secondary Power Type of secondary power: Storage Battery Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours): 24 In alarm mode(minutes): 15 5.2 Control Unit Power extender panels are listed on the supplementary form Notification Appliance Power Panel Supplementary Record Of Completion. 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line Device Power Initiating Device Level 0 Class B Level 0 Notification Appliance Level 0 Class B Level 0 7. REMOTE ANNUNCIATORS Address Type Location 8. INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology 9. NOTIFICATION APPLIANCES Type Quantity STROBE 2 SPEAKER STROBE 6 10. SYSTEM CONTROL FUNCTIONS Type Quantity 11. INTERCONNECTED SYSTEMS • 'SIEMENS NFPA 72 REPORT I .t4ily-for tiff_ 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This Testing Was Performed in Accordance with Applicable NFPA Standards. Sig Date: Printed n- e: Grant Bahner Organization: SIEMENS Title: SPECIALIST 2 Phone: 971-207-1900 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signe".. Date: Printed na or: Grant Bahner Organization: SIEMENS Title: SPECIALIST 2 Phone: 971-207-1900 12.3 Acceptance Test Date and time of acceptance test: 02 Nov 2022 0600 Installing contractor representative: DAVID HEMMER Testing contractor representative: Grant Bahner Property representative: AHJ representative: City of Tigard, Or