Loading...
Permit Site Address: 10031 SW Cascade Ave. Tigard, OR 97223 Building Division TIGARD Deferred Submittal Transmittal Letter TO: TOM HOCHSTATTER DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVEj' FROM: ERIC HAYWARD SEP 2 7 2022 COMPANY: HOWARD S. WRIGHT CITY OF TIGARD i , BUILDING DI�j�SION/4 PHONE: 503.320.9317 j diT -1000 co RE: JJJ3�'SW CASCADE AVE. (Site Address) (Pennit/Case Number) TIGARD BMW LOT 1200 Item# 01 (Project name or subdivision name and lot number) Valuation of Deferred Submittal: $ 1,021,760 ATTACHED IS THE FOLLOWING DEFERRED SUBMITTAL ITEM: Copies: Description: 2 Engineered Aggregate Pier Drawings, Details, and Calculations _ 1 Review Completion Email Chain from Inspector Tom Rogers Remarks: Approved Drawings for Deferred Submittal. Please Contact Eric Hayward (503) 320 9317 ehayward@hswc.com with questions and comments. NOTE:Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building.The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official. Oregon Structural Specialty Code Section 106.3.4.2 FOR OFFICE USE ONLY Routed to Permit Technician: Date: Initials: Fees Due: ❑ Yes_ n No Fee Description: cf40,-0 Amount Due: Deferred Submittal Fee: 01 ) $ if�i I-r Additional fee based on v uation: al 61 9 8 Other: $ Total Fees Due: $ 3 a3 1 . 9 $ Special Instructions: Reprint Permit(per PE): ❑ Yes No ❑ Done Applicant Notified:a Date: Lb/pig y / // ���, Initials: The fee for processing reviewing eferred plan submittal shalt be mount equal to 65%of the building based on the valuation of the particular portio or portions of the project with a minimum$200.00 fee.This fee is in addition to the project plan review fee bas on the total project value. 1:Building\Forms\TiansmittalLetter-De rdSubmtl.doc 04/04 j) -71 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Brandon Tagged DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED FROM: Jesse Emerson OCT 19 202Z COMPANY: 3J Consulting CITY OF TIUARD BUILDING DIV y! PHONE: (503)946-9365 x 202 EMAIL: jesse.emerson@3j-consulting.com RE: 9825/9875 SW Cascade Avenue 51-rzoZ' .--cooi(P (Site Address) (Permit Number) BMW of Tigard (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s)of plans. 3 Revisions: Landscaping Plans Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. _ Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Type I Modification obtained for site work permit. Updated landscaping plans were required for modification approval. FOR OFFICE USE ONLY Rou to Permit Technician: Date: 10 Initials: Fees Due: Yes ❑ No Fee Description: Amount Due: O• r ,P)�.,�, rr v; ��✓ $c.,11 --� Special Instructions: Reprint Permit (per PE): ❑ Yes 'No ❑ Done Applicant Notified: Date: 1k 1 ra I x-2._ Initials: :Nip CITY OF TIGARD SITE WORK PERMIT COMMUNITY DEVELOPMENT Permit#: SIT2022-00016 T i t_d Ark f7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/25/2022 Parcel: 1 S 127DD01200 Jurisdiction: Tigard Site address: 9875 SW CASCADE AVE Project: BMW of Tigard Subdivision: None Lot: None Project Description: Site work for a new 262,000 sq.ft.automotive dealership building with service center and parking structure. Contractor: HOWARD S WRIGHT Owner: HOLMAN TIGARD REAL ESTATE LLC 1455 NW IRVING STREET#400 17800 SE MILL PLAIN BLVD#190 PORLAND, OR 97209 VANCOUVER, WA 98683 PHONE: 503-601-9939 PHONE: FAX: FEES Description Date Amount Specifics: Permit Fee-Site Work 10/25/2022 $9,735.54 Plan Review 07/28/2022 $6,328.10 Type of Use: COM 12%State Surcharge-Building 10/25/2022 $1,168.26 Class of Work: NEW Info Process/Archiving-Lg$2.00(over 10/25/2022 $58.00 Project Valuation: $2,087,780.00 11x17) Info Process/Archiving-Sm$0.50(up to 10/25/2022 $62.50 11x17) Erosion Control w/Development 10/25/2022 $1,661.40 Site Specifics: Excavation Volume: 10195 cu.yd. Fill Volume: 16395 cu.yd. Impervious Surface: 4786 sq.ft. Engineered Fill: Yes Soil Report Required: Yes Paving: No Grading: Yes Landscaping: No Site Prep: Yes Storn Drains: Retaining Wall: Fire Underground: No Accessible Parking: Yes Fence: Yes Total $19,013.80 Required Items and Reports(Conditions) 1 Ersn Cntrl 503-639-4175 2 Special Inspection(see plans) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion oft project. Approved plans are required on the job site at the time of each inspection. City of Tigard: Site Work Permit Checklist Page 2- Supplemental Information Commercial,Multi-Family and One-and Two-Family Dwellings: No permit is required if fill is less than 50 yards (5 dump truck loads), or less than 3 feet deep and will not be supporting a structure. If a building will be constructed on the fill, it must be engineered fill. If fill is in a flood plain, drainage way, or wetland,the applicant must apply for a sensitive lands review (SLR). Please complete all items below,unless otherwise noted. Excavation Volume: 10,195 cu.yds. Grading Volume: (Soils report required for>5,000 cu.yds.) 26,590 cu. yds. Fill Volume: (Fill exceeding 12"in depth shall be compacted to 90% of maximum density) 16,395 cu. yds. Retaining structure? (Check one) ❑ Rock ❑ CMU ❑ Concrete O Other: *Total new impervious area including all buildings, sidewalks, and paving: 4,786 sq. ft. Site Utilities Plumbing Work: Complete the Plumbing Permit Application for site utilities plumbing work. Plans Required: See"Site Work Permit Application-Plan Submittal Requirements"attached. The following must accompany this application: X❑ Site Plan with Vicinity Map showing ADA 0 *Parking(including ADA)and Lighting compliance Plan ❑X Grading Plan and details 0 *Landscaping Plan 0 Erosion Control Plan and details 0 Soils Report(if required) 0 Retaining Structures *Does not apply to One-and Two-family dwellings. Plan Submittal: Permit Fee: TYPE OF SUBMITTAL #of Plans Valuation: Permit Fee: (New,Additions or Required at $.00 to$500.00 $51.09 minimum permit fee Alterations) Submittal $500.01 to$2,000.00 $51.09 for the first$500.00 and $2.69 for each additional$100 or fraction 3 Commercial thereof,to and including$2,000.00. $2,000.01 to$25,000.00 $91.44 for the first$2,000.00 and Multi-Family R-1 Occupancy 3 $10.76 for each additional$1,000 or fraction thereof,to and including $25,000.00. One-&Two-Family Dwelling 3 $25,000.01 to$50,000.00 $338.92 for the first$25,000.00 and $8.06 for each additional$1,000.00 or fraction thereof,to and including $50,000.00. $50,001.00 to$100,000.00 $540.42 for the first$50,000.00 and $5.38 for each additional$1,000.00 or fraction thereof,to and including $100,000.00. $100,000.01 and over $809.42 for the first$100,000.00 and $4.49 for cach additional$1,000.00 or fraction thereof. I:\Building\Permits\SIT-PermitApp.doc 08/02/2016 2 City of Tigard li4 COMMUNITY DEVELOPMENT DEPARTMENT t 7-ICA}z1? Building Permit Review — Commercial - With Land Use I. Building Permit #: j- J --(jr_x)'4, She Address: 0I%l S CV'J C f�( ,C Suite/Bldg#: Project Name: (Name of commercial business occupying the space. If vacant,enter Spec Space.) Planning Review Proposal: glitz Wb +f1tk AVerify site address/suite# exists and active in permit system. River Terrace Neighborhood: ❑ Yes / No gr Land Use Case#: S}.lQ22 — 1 7 Plans Match Approved Land Use: X Site Plan /Landscape Plan Other. j XUrban Forestry PlanPlan Elevation Building Height Maximum Height 6tual Height 4 Conditions Met Prior to Submittal Prior to Permit Issuance tUk Business License: Exists: ❑ Yes ❑ No,applicant was provided a business license application Iff Public Facilities Improvement(PH) Permit: W12022 00-16+ Required: ,Yes,applicant was notified 0 No Applied For: Yes 0 No,stop intake Notes: VW , Approved by Planning: Illli Date: 1 1$ ZZ- Revisions (after Building Submittal o r Reviewer Date Revision 1: ® Approved 0 Not Approved .I� 4,411, 10/19/2022 Revision 2: 0 Approved 0 Not Approved Q Revision 3: 0 Approved 0 Not Approved _. . Building Penanit Submittal Original Submittal Date: 7 / .Vie ' Site Plans: # ,,' Building Plans: Building Permit#: ter building permit#above. Workflow Routing: dung 7 eering alrrrmit Coordinator trETAlding Workflow Sign-off � off for Planning(include notes from planning review) Route Application Documents: t7 Building original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: _ By Permit Technician ^�:.e. _ y /? g - 2//Vid- t • / I:\Building\Pones\BldgPernutRvw_COM_WithlandUse_111819.doex Engineering Review L:7 Slope at building pad: 2-14 G'PFI Permit#: pF 202�—Oozs 4(._ ❑ Conditions "Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat (not typical on SDR/CUP) ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes Er No Assess Water Quantity Fee in-lieu: ❑yes El/No LIDA Facility on lot: Yes ❑ No Add Fee: ❑ Yes ['No ❑ NOT Approved by Engineering: Date_ Notes: IA,poi y 5Q- Vvil't‘l It Cvndrf1 $ aY2 n401 e,f YIAS 1P�Nt ISSo4OI. Approved by Engineering: erg'i - arctkel Date: R /21/2ozz. Revisions (after Building Submittal only) Reviewer Date Revision 1: Q'Approved 0 Not Approved 7 e,.-.f- £ 1012st/2& t Revision 2: El Approved 0 Not Approved Revision 3: El Approved ❑ Not Approved Permit Coordinator Review tV Conditions "Met"prior to issuance of building permit At,Approved,NOT Released: 1Noti' Ot t (J he'6 "VO toe P *W «I �Dat: -,144(0vZ Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: 0 Yes /N/A Tigard Trans SDC: ❑ Yes A N/A Parks SDC: ❑ Yes p� N/A 1 LIDA Fee: 0 Yes N/A /OK to Issue Permit Approved by Permit Coordinator: /`-1 A_ Date: 1OIZSJ(2o?_2_ V I:\Building\Forms\BIdgPermitRvw_COM_WithLandUse_111819.docx