Report P'i,2C 2c7 Z2 -o 10i, 12.S-14o (2 Ng- • Whis /V�■erCeilin •DC' FV-0511VQ1 VENTILATION(FAN Specification Submittal Data /Panasonic Precision Spot Ventilation Fan 4" or 6"Duct Description: Ceiling Radiation Dampen. e . Ventilating fan shall be Low Noise ceiling mount •WhisperCeiling®DC-is UL listed for use , �-.% l V type rated for continuous run.Fan shall be with the Panasonic Ceiling Radiation Damper iiiilu ENERGY STAR®rated and certified by the (Model#:PC-RD05C5,sold separately). "a , Home Ventilation Institute(HVI).Evaluated by Grille: Underwriters Laboratories and conform to both , ! UL and cUL safety standards. •Attractive design using Poly Pro material. •Attaches directly to housing with torsion Motor/Blower. springs. •Enclosed brushless ECM motor technology Warranty: rated for continuous run. •ECM Motor:6 Years from original purchase •Fan ventilation rates shall be manually date. FV-0511VQ1 adjustable for 50-80-110 CFM. •ALL Parts:3 Years from original purchase •Power rating shall be 120 volts and 60 Hz. date. •Fan shall be UL and cUL listed for tub/ run continuously.ECM motor speed shower enclosure when GFCI protected. Architectural Specifications: shall automatically increase when the •Motor equipped with thermal cutoff fuse. fan senses static pressure to maintain • Ventilation fan shall be UL and cUL listed for selected CFM.Power ratingshall be Removable with permanently lubricated plug- ceiling mount and tub/shower enclosure when 120V/60Hz.Duct diameter hall be no in motor. GFCI protected.Fan shall also be ENERGY ® less than 4",inclusive of an integrated Housing: STAR®certified,with a built-in speed selector. dual 4"or 6"duct adapter.Fan can be •26 gauge Zinc-Aluminum-Magnesium(ZAM) Choose from 50-80-110 CFM and no more used to comply with ASHRAE 62.2, housing than<0.3/<0.3/<0.3 sone as certified by the LEED, ENERGY STAR®IAP,EarthCraft, •Integrated dual 4"or 6"diameter duct Home Ventilating Institute(HVI)at 0.1 static CA Title 24 and WA state code. adapter. pressure in inches water gauge(w.g.)with •Buitt-in damper reduces back drafting and no less than 53-83-111 CFM and no more RECEIVED helps with blower door testing. than 0.4/0.6/0.9 sone as certified by HVI at •Built-in metal flange provides blocking for 0.25 w.g.Power Consumption shall be no penetrations through drywall as an Air Barrier, greater than 4.0/5.9/10.6 watts at 0.1 with CET 2 5 anM1 and assists with the decrease in leakage in the and 7.2/10.8/16.4 watts at 0.25 w.g.,with W i �u�i Building Envelope during blower door testing. efficiency of no less than 12.5/13.6/10.6 CFM/ •Articulating and expandable installation watt at 0.1 w.g.and 7.4/7.7/6.9 CFM/watt at CITY OF TItaAAD bracket up to 24". 0.25 w.g.The motor shall be totally enclosed BUILDING DIVISION with a brushless ECM motor engineered to performance Curve 4"Duct Specifications:WhisperCelling DC FV-0511V01 4" 4" 4° Static Pressure in inches w.g. 0.1 ® 0.1 ® 0.1 ® °a Air Volume(CFM) 110 111 80 83 50 53 l _ 11V01 j S0 1100nl Noise(sones) <0.3 0.9 <0.3 0.6 <0.3 0.4 100M, Ventilation Fan Power Consumption(watts) 10.6 16.4 5.9 10,8 4.0 7.2 a"0 __.-..,, Characteristics Energy Efficiency(CFM/Watt) 10.6 6.9 13.6 7.7 12.5 7.4 0. _,.a•,,, (HVI Certified Speed(RPM) 957 1239 821 1172 756 1093 1°301 .mm0 Data) Current(amps) 0.18 0.26 0.11 0.18 0.07 0.13 0.20 ? - ;' vron a,a MAX.Current(amps) 0.27 •'BOO duet 0.10 Power Rating(V/Hz) 120/60 •loon•'° _ 1 ENERGY STAR rated Yes 0 i0 20 30 40 SO 40 00 0) so MO 110 120 u 0.25=Installed Performance •••IOEMI For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Eeo Solutions North America e.F4,4r. ECM Motor Technology Sea Products azaDivision rf When the fan senses staticpressure,its speed is automatically Riverfront Plaza #+ P increased to ensure Newark,NJ 07102 t,*».--;-',-, that the desired CFM is not compromised,which allows the fan to perform as rated. HNOt us.panason ic.com/ventfans ® Mire"' ifi 1 us ES Panasonic HI,a VF17564SS0917 Titus Submittal D-PAR-1.0 5-10-06 PAR • Return Perforated Ceiling Diffusers Steel • Flush Face Border Type 3 (Lay-In when D=Module size-2) Nominal Duct Size D - [..„ D minus 1/8" -- - - 1 21/8" 4s o.oa. 4.••.s. fi-- Ceiling Module Minus 1/4" -- Ceiling Module Size - ❑ Border Type 3 (Lay-In for other duct sizes shown) Nominal h Duct Size D - D minus 1/8" - } 4.Ds.°. - Ceiling Module minus 1/4" -I 1- -Ceiling Module Size - ❑ Border Type 1 (Surface Mount) ❑ Border Type 2 (Snap-In) Nominal Face Size minus 1- r 1"Border [ol Jl �I I t 1/4" --! Ceiling Module Size Nominal Face Size — minus 1116" Nominal Face Size plus 1" - ❑ Border Type 4 (Spline) ❑ Border Type 4SL(Spline Side Lock) _LIL ■ Ceiling Module Size Ceiling Module Size - minus 1/16" minus 1/16" Note:4SL can be installed after ceiling tiles are in place. ' D-PAR-2.0 5-10-06 Available Sizes for Border Types t2,3,4,4S Face or Nominal Duct SizeD Ceiling \r . . Module 6x6 8x8 fl x ID 12 x12 14x14 5x5 ex6 5x18 22x1J 22x22 46 x22 6" Dia. 8" Dia. I)" Dia. /2" Dia. 14"Dia. 16" Dia. Size 12x12 • 24x12 • 5x16 • • • 20 x20 • ----_____,24 x 24 . 48x24 • • • • • • •Indicates available combination. Removing Perforated Face 1.Insert small Screwdriver 3.Face will now swing : ' ------ or other slim instrument to != down with 2 remaining push latch inward from 0 latches acting as hinges. border. � 10 For complete removal, 2.Repeat on opposite side. r/ si release 2 remaining latches at left. Accessories (Optional) Check [ 'if provided. ❑Model AG-95 Opposed Blade Damper 0 Model AG-35B Opposed Blade Damper AG-95 Mounts AG-35B EG Mounts on Neck 1 1/2" in Duct . ,is. a ORM 1 3/4•• ao I /+ --, Lever Operator Slot Operator (Remove Face for Access) (Remove Face for Access) ❑ TRM TITUS Rapid Mount Frame _ For Surface Mounting Border Type 3 ❑ IB Molded Insulation Blanket Insulation is R-6 where blanket has the most depth. One-inch clearance on each I side of neck is left for insulated duct connection.24 x 24-inch module size only. Blanket is factory installed. D-PAR-3.0 5-10-06 Standard Finish: #26 White General Description • Model PAR flush face perforated • Optional damper is easily • Material is heavy gauge steel. ceiling diffusers are designed for adjusted by dropping the use as returns to match the Model perforated face (see page 2). PAS supply diffusers. • Perforated face has 3/16" • Can be mounted in a plenum or diameter holes on '/"staggered connected to a return duct. centers. This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus �`j " r tus O reserves the right to make changes without written notice. 605 Shiloh Road•Plano,Texas 75074•972-212-4800 AS r1Ms reserved kb pad of ary may be reproduced or transmitted In any goon or by any mean,NICVCnnc u mennanina EKMtltllg pin4copying and panorama,or by any Intlnetw Ndage rental system moot PmnMm In wnUM men,Av d.9tnblalan Teebpkdee * Titus Submittal PCS 5-7-15 Perforated Ceiling Diffusers Steel • Flush Face • Curved Blade Model: PCS • Supply • 4-Way Adjustable Discharge Pattern ❑ Border Type 3 (Lay-In) Nominal 24 x 24"Backpan f~Duct Size D (Shaded Sizes in Table) r_D minus 1/8^ —8-1 Non-24 x 24" Backpan f J BA . °W 0 0 ::I L --� a F Ceiling Module Minus 1/4" Ceiling Module Size 1 Face or Ceiling Dimension Module Size Neck Sizes A B 12x12 6,8 4 2 12x12 6x6,8x8 33/8 13/8 24 x 12 6, 8 3 1/2 1 1/2 24X12 6x6,8x8,18x6 31/2 1 1/2 16 x 16 6,8,10 3 1/2 1 1/2 16x16 6x 6,8x 8,10x 10.12x 12 31/2 11/2 20 X 20 6.8,10,12,14 3 1/2 1 1/2 20 x 20 6 x 6.8 x8,10x 10,12 x 12 31/2 11/2 6,8 3 1/4 1 24 x 24 10,12,14,15,16 3 3/4 1 1/2 6x6,8x8,10x10 33/4 11/2 24 x 24 12x 12,14 x 14,15x 15,16x 16 33/4 11/2 48x24 6,8,10,12,14,16 31/2 11/2 48x24 6 x6,8x 8,10x 10,12x 12,16 x 16,18 x18 31/2 11/2 ❑ Border Type 1 (Surface Mount) ❑ Border Type 4 (Spline) Note: Type 4 border is not available in 16x16 Nominal Face Size Non-24x24 Backpan or 20x20 module sizes. minus 1 1"Border i f I o.onjilt 24 x 24 Back Pan IIJIoe•:•o o o.•o• aaaaaaa 1 • • 1/4 • • • • . • • • I Nominal Face size — Ceiling Module Size y.. Nominal Face Size plus 1 — minus 1/18" Available Sizes Face or Ceiling Nominal Duct Size D Module 6 x 6 8x8 10x 10 12x 12 14x 14 15x 15 16x 16 18x 18 18x 6 6"Dia. 8"Dia. 10"Dia. 12"Dia. 14"Dia. 15"Dia. 16"Dia- Size 12x12 • • • • 24x12 • • 16x16 • 20x20 • • • . • 24x24 • • • • • • • • • • • 48x24 • • • • •Indicates available combination All dimensions are in inches • PCS 5-7-15 • • Removing Perforated Face 1. Insert small Screwdriver or _ 3.Face will now swing i other slim instrument to push ® $ --1' down with 2 remaining ' 1 ) latch inward from border. e latches actin 9 as hinges. 2.Repeat on opposite side. For complete removal, i release 2 remaining °°°°° °°°°°° °o eoo°ve ovo°° latches at left. ,°°°° Adjusting Pattern Controllers Check 'if provided. ❑ Round Neck•4-Way(standard) ❑ Square Neck•4-Way(standard) Tension wire holds blades in position after pattern has been adjusted. II � III o\ ° o\ n C.;;,° •••• Individually adjustable The standard Model PCS diffuser has curved blades. The pattern deflector in the neck of a 4-Way discharge pattern.Also the diffuser consists of individually available are: adjustable blades.These blades vary the discharge pattern from full ❑ 1-Way horizontal to vertical and also damper the air volume. ❑ 2-Way Opposite ❑ 2-Way Corner ❑ 3-Way Accessories (Optional) for Round Neck Check dif provided. ❑ Model AG-100 Radial Sliding Blade Damper ❑ Model D-100 Radial Sliding Blade Damper ❑ Model EG Equalizing Grid ❑ Model EG Equalizing Grid AG-100 + EG EG ' Mounts Above Neck 1 1/2" - D-100 1 1/2" � l'l _A i- Mounts on Neck 1 3/4" HH�� p Model AG-100 damper is available in duct Model D-100 damper is available in duct _ sizes 6 thru 14 inches only. sizes 6 thru 14 inches only. • PCS 5-7-15 Accessories (Optional) for Round Neck, continued ❑ Model D-75 Opposed Blade Damper ❑ Model AG-75 Opposed Blade Damper ❑ Model EG Equalizing Grid ❑ Model EG Equalizing Grid I EG D-75 AG-75 11/2" ninffk Mounts on Neck I, EG `, Mounts Above Neck } 11/2" I11 iIli + 7 A T s '/x: + + A I- r Size B Model D-75 damper is available in duct biz >uz sizes 6 thru 12 inches only. 14 21/8 Dimension"A"in Inches,for Dampers Shown Above Nominal Round Duct Sizes Notes: Accessories 6 8 10 12 14 Model AG-100 and D-100 dampers have AG-100 — — — — — radial blades that slide in a horizontal plane. For that reason, no opening D-100 — — — — — clearance"A"is dimensioned. D-75 2 3/8 3 1/4 4 1/8 4 7/8 N/A AG-75 4 1/4 5 1/8 6 6 7/8 2 3/4 EQT — — — — — Accessories (Optional) for Rectangular Neck Check 'if provided. ❑ Model AG-95 Opposed Blade Damper ❑ Model EG Equalizing Grid ❑ EQT Earthquake Tabs(2 per Diffuser) EG AG-95T Mounts 11/2" WWII on Neck 1 3/4" Lever Operator (Remove Face for Access) Nominal Round Duct Sizes Accessories 6 x 6 8 x 8 10 x 10 12 x 12 15 x 15 18 x 18 ❑ AG-95 • ❑ EG • • El EQT • Standard Finish: #26 White General Description • Model PCS flush face perforated ceiling • Discharge pattern is easily adjusted by • Inlet collar is approximately 1'%" diffusers are designed to maximize throw. dropping the perforated face(see Page 2) deep to allow easy duct connection. • Excellent performance in variable air and adjusting the curved blades. • Material is heavy gauge steel. volume systems. • Dropping the perforated face also gives . • Discharge pattern can be adjusted from access for adjusting the optional damper. horizontal to vertical.Can be adjusted • Perforated face has 3/16"diameter holes before or after installation. on%"staggered centers. This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus reserves the right to make changes without written notice. Alrghus.e9erv<A.900«0Wmlavrom marle.1PWucm o.tar"m000lr.aoyl«m«0Y anymnno,400onmv ma.,000p.i000n90000 Ann9•nd nc«On, e c«v>nv•romaem am..ga remw•i.yxm."wn Dam:.alo""rmn�imm a.oamwam remnoxq"a.