Specifications . Zv? 2O22 -Ooall • •• ••• ••• •• • •• • ••• • • • • • • • • • • • Scope of work is for the design of the sign pole,splices and the foundation. • • CO •• • So -Q • • • • ••• • • • • • • • • • • • LOADING: • • • • • •.i._ • •• 4 Code ASCE7-16 Vv.= 97 mph(3 second gust) F=gz•G•C110.6:(allowable) Exposure= B Kz .z F(•sf) h • • •• ••• Overall Height,h= 20.00 ft 0.57 11.87 10.5 0-15ft •• •• • + • • • • Cabinet Area= 70 0' 0.62 12.69 11.4 15-20ft • •• • I. • ••• • t • Est.Cabinet wt.= 15 psf ; •• • bi Est.Pylon Mass= 1050 lb =70'15psf ••�'I✓ •• Center of mass= 15.63 ft(cabinet) I,pole= 68 in la'sct14o1 CO Roark's Table 16.1,Case 3c Nat.freq.,nt= 2.60 >1.0,consider 401ngidRECEIVED .;. .;. . . .. .. Gf= 0.85 • •• •• Kzt= 1.00 (Ego.26.0-1) • • ••• ••• "• • • • • • • • • i, Kd• 0.85 (Table 261)0- Cf= 1.77 (Figure 2B.3-1J NOV 1 0 ` • ••• • • • ar • • s= 8.75 ft s/h= 0.44 O 02 e= 8.00 n(cedaa sexro windload) CITY OF TIGARD I 6" DIA. offsetx= 0.00 ft(ho dist.bcabinMs) BUILDING DIVISION o SCH. 40 x= 0.00 ft(o-adist.bkn.poles) PIPE Fl= 100% %bad to pole Splice. S P E FORCES: location:1 11 25 Ift SPLICE VNdth Height to Heigh to Area Wind load'(psf) Force Height to Moment(ft-Ht.(tt) Moment bottom(0) top(ft) (sq.ft.) (lb) center(II) lb) (ft-lb) DETAIL 8.00 15.00 20.00 40.0 11.4 456 17.50 7980 8.25 2850 8.00 11.25 15.00 30.0 10.5 315 13.13 4134 1.88 591 s 8" 0.72 0.00 11.25 8.1 0.0 0 0.0 1910 ,., � DIA. 0.00 3.0 0.0 0 0.00 a `.' iI _.l: 0.00 0.0 0.0 0 0.00 0 i' � I SCH. 40 0.00 0.0 0.0 0 0.00 0 0.00 0.0 0.0 0 0.00 0 ®/V 11 4 fi PIPE 0.00 0.0 0.0 0 0.00 0 0.00 0.0 0.0 0 0.00 0 olio 0.0 0.0 0 0.00 0 0.00 0.0 0.0 0 0.00 0 _ I 0.00 0.0 0.0 0 0.00 0 "-I L= 805 5 -'� . 12305 3441 t II 'Cf adjusted at pole sections at base at Upper splice - " SIGN POLE: Double Staged 0 Base Post I " Fy= 35000 psi T= 1288 fl-lb =80511.6') SIGN POLE PER CO - zx= 20.80 •in Tc= 34224 fldb ELEVATION, TYP. .. Zy= 20.80 ins 0.04<0.2 torsion can be neglected 1/2" H TYP 1 Mx= 12305 ft-lb - Mot= 36327 ft-lb =35000'20.8/12/1.67 TYP- II 1/2" COLLAR 1 ----, 12305 <36327 OK,34% PLATE, TYP. My= 0 ft-lb )dry= 36327 ft-lb =35000'20.8/12/1.67 ,p TYP. 3 -� Use a PIPE 8"SCHae sign pole j DIA. Upper Post ZxFy= 0 psi o= , 4 ft-lb =771'(1.8] // SIGN -L E V A T 0� Zx= 10.60 ins To= 17400 ft-lb 1/4 TYP. / Zy= 10.80 is, 0.07<02 torsion can be neglected IL__ __ Mx= 3441ft-Ito \ / Moo= 1851513 ft-Ito =35000'10.6/12/1.67 ,fie 10c 3441 <18513 OK,19% 0"O.C. My= 0 ft-lb1/2" RING Mcy= 18513 ft-lb =35000'10.6/12/1.67 n T PLATE, TYP �' ROFF�, Use a PIPE 6"SCH40 sign pale I SPLICE DETAIL c'\PPa p FOUNDATION CHECK: - J N.T.S. G I N .O Son Depth 1.00 ft(to ignore) Lr�� � f� Mn t= Uli 0.805 k� -(12305)'100%/1000-3.6711-k'e(0.805k'1') cc's`./ `` 725 5PE /1 N./c.c.)= 11.73 i ft q= 150 psf/ft assumed lateral soil-brg. q'= 300 psfft =150'2(allowable big.with//2"movement) . ' I,• ON O Footing shape:Circular O b= 3.00 ft diameter R' Q 3.00 ft diameter • , , �'Y 08 , ��P b'= 3.00 ft diameter ✓OSEPH���d t•m„„„4l= 5.00 ft Estimated embedment Unconstrained Condition volume of concrete= 1.3 yd EXPIRES:12-31-2022 s_1= 500 psf q'd_est/3 fooling w4= 5.3 k A= 1.26 ft 2.34•P•1000/(S l'b) est,sign wl.= 1.56 k(with poles) d= 4.68 fl N2'(1+(1t4.36'h/A)..5) Total wd(DI)'0.6= 4.12 k 4.68<5'OK eccentricity of load to reaction(e)= 0.89 ft=3.67/4.12 maximum resistive moment available based on soil bearing,M„,= 3.67 ft-k Use 3'.0"diameter x 6'.0"deep concrete footing Single Continuous Footint1 allProject Name After 5 LLC Pylon Sign Project# 221219 MILLER_ ENGINGINEEEERSRS Location 12995 SW Pacific Highway, Tigard OR EN Client Meyer Sign Company of Oregon 9600 SW Oak St#400 503.246.1250 p�� 8/12/2022 1 of 3 Portland,OR 97223 miller-se.com By GSD Ck'd (..lr1 Date Page „ ,, , ,• ,• , , , , •, • GENERAL • • • �•• • THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE -- REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE:c I-RACTDR 'SIciALLMEQLIEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNIND THr'PROJtCT.THEA$$ENGJ OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED ANJx fAfQIJ,IARUP NIMSELINVIjy.ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. • - THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED SrRUCTURe LINCEIS:OZ'HtRWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION 3DR (:JN$tQUMYOQI'LOQD$. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO'PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD.ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. ANALYSIS FOR MOVEMENT DUE TO VORTEX SHEDDING OF WIND FORCES IS NOT INCLUDED IN THE SCOPE OF WORK. IF MOVEMENT CAUSED BY VORTEX SHEDDING IS A CONCERN, WIND TUNNEL TESTING OR OTHER ANALYTICAL MODELS SHALL BE UTILIZED TO EVALUATE THE STRUCTURE. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2019 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2018 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. GINS 4. 444 -725 5PE 100 V. o ON ti Q ' RY 0a rypP ✓OSEPH M” EXPIRES:12-31-2022 it Project NameAfter 5 LLC Pylon Sign Project# 221219 MILLER _ ENGINELERS Location 12995 SW Pacific Highway, Tigard OR NSUIG E Client Meyer Sign Company of Oregon 9600 SW Oak Sc P400 503.246.1250 /'`�y 8/12/2022 2 of 3 Portland,OR 97223 miner-se.com By GSD Ck'd H/� ` Date Page • • • . • . • DESIGN LOADS • •• �� t ;� •• • •� ' • • • THE FOLLOWING ARE THE DESIGN REQUIREMENTS: : �4 �6 � tv - /0 ' .• STRUCTURAL DESIGN CRITERIA - 4' 725 5PE 4 fili RISK CATEGORY II •: , •: A ': :'• •'• WIND DESIGN DATA �'. � "1 ! 1. O~ ::• ••• BASIC WIND SPEED(3 SEC GUST) 98 MPH j Ea ow, 4- "' "' EXPOSURE B ✓OSEPH\t`l FOOTINGS •• • :EXPIQES231t0 2• : : : FOUNDATION CRITERIA : • CONTRACTOR SHALL VERIFY SOIL CONDITIONS AT THE FOOTINGS AND MAKE AIQY INAGESSAF:' CCIRI:ECI?JNS TO PLACE THEM ON FIRM NATIVE SOIL OR STRUCTURAL FILL COMPACTED TO 95% OF MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT PER AMERICAN SOCIETY FOR TESTING AND MATERIALS, ASTM D698 (STANDARD PROCTOR), OR ASTM D1557 (MODIFIED PROCTOR). THE COMPACTION SHALL BE VERIFIED BY A QUALIFIED INSPECTOR APPROVED BY THE BUILDING OFFICIAL. COMPACTED STRUCTURAL FILL FOR DEPTHS GREATER THAN 12 INCHES SHALL COMPLY WITH PROVISIONS OF AN APPROVED GEOTECHNICAL REPORT. ASSUMED SOIL BEARING PRESSURE 1500 POUNDS PER SQUARE FOOT(PSF). CONCRETE MIXING, PLACING AND CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE, ACI 318 AND IBC CHAPTER 19. CONCRETE SHALL BE 3,000 POUNDS PER SQUARE INCH (PSI) MINIMUM AT 28 DAYS. DESIGNED FOR 2,500 PSI, NO SPECIAL INSPECTION IS REQUIRED. ALL CONCRETE WITH REINFORCEMENT SHALL HAVE NO CHLORINE OR CHLORIDES. WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING CONCRETE SURFACE SHALL BE CLEANED AND ROUGHENED TO A MINIMUM 1/4" AMPLITUDE PER ACI 318 11.6.9. SET ALL ANCHOR BOLTS AND DOWELS BEFORE POURING CONCRETE. REINFORCING STEEL ALL REINFORCING STEEL SHALL BE DEFORMED BARS PER ASTM A615 OR A706 GRADE 60.ALL REINFORCING STEEL TO BE WELDED SHALL BE ASTM A706.ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. UNLESS NOTED OTHERWISE, SET MAIN REINFORCING STEEL 3" FROM EARTH AND 2"FROM FORMED SURFACES. BAR LENGTHS DETAILED ARE OUT TO OUT AND DO NOT INCLUDE ALLOWANCE FOR HOOKS OR BENDS. USE MINIMUM 30" LAP FOR#4 BAR AND SMALLER UNLESS NOTED OTHERWISE (UNO). USE MINIMUM 36" LAP FOR #5 BAR UNO. ALL REINFORCING STEEL SHALL BE SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL CHAIRS, AS SPECIFIED BY THE CRSI MANUAL OF STANDARD PRACTICE, MSP-1, AND SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH THE "ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES,"ACI 315. STRUCTURAL STEEL ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE ASTM A992 FOR W-SECTIONS AND ASTM A36 FOR ALL OTHER SECTIONS, PLATES AND BARS.ALL RECTANGULAR HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY=46000 PSI AND ALL ROUND HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY = 42000 PSI. ALL STRUCTURAL STEEL PIPE SHALL BE ASTM A53, GRADE B, TYPE E OR S, FY= 35000 PSI. ALL STEEL IN CONTACT WITH ALUMINUM TO BE HOT DIPPED GALVANIZED OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. UNLESS NOTED OTHERWISE, ALL BOLTS TO BE ASTM A307 AND ALL ANCHOR RODS TO BE ASTM F1554 GRADE 36, WITH MATCHING NUTS. ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE BE HOT DIPPED GALVANIZED WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION PER RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS, SECTION 8.1. ALL STRUCTURAL STEEL SHALL HAVE ONE COAT OF PRIMER, EXCEPT SURFACES TO BE EMBEDDED IN CONCRETE OR MASONRY. EMBEDDED SURFACES SHALL BE FREE OF CONTAMINANTS. ALL ZINC (GALV.) COATINGS ON IRON AND STEEL PRODUCTS SHALL CONFORM TO ASTM A123. REPAIRS OF GALVANIZED COATINGS ARE TO CONFORM TO ASTM A780. ALL EXPOSED STRUCTURAL STEEL TO HAVE ONE FINISH COAT OF RUST INHIBITING PAINT, COLOR BY OWNER. Project Name After 5 LLC Pylon Sign Project# 221219 -t MILLER CONSULTING 12995 SW Pacific Highway, Tigard OR ENGINEERS Location Client Meyer Sign Company of Oregon 9600 SW Oak St 11400 503.246.1250 8/12 Portland,OR 97223 miler-se.com By GSD Ck'd Date �2D22 Page 3 of 3