Loading...
Specifications SU 1P262Z-Q3240 Alrit MILLER CONSULTING ENGINEERS STRUCTURAL CALCULATIONS Everbowl Canopy Signs 11858 SW 72nd Avenue, Tigard, OR Meyer Sign Company of Oregon August 22, 2022 Project No. 221267 4 pages Principal Checked: �\ GINF 0 ‘4' 7252 E N o ,� 2G ti� 9Plie o a �QpP 9✓OSEPH MP EXPIRES:12-31-2022 *** LIMITATIONS *** Miller Consulting Engineers, Inc.was retained in a limited capacity for this project. This design is based upon information provided by the client,who is solely responsible for accuracy of same. No responsibility and or liability is assumed by or is to be assigned to the engineer for items beyond that shown on these sheets, 9600 SW Oak Street,Suite 4001 Portland,Oregon 97223 1 503.246.1250 1 www.miller-se.com Scope of work is for the design of the connection of the sign to the existing canopy. Inbut Data:ASCE 7-16 Maximum Height(h)= 15.00 ft(of sign) Wnd Speed,V= 98 mph Exposure Category= B Topo.Factor,Kzt= 1.00 Direct.Factor,Kd= 0.85 Effective Area,Ae= 12.66 fte (Area Tributary to C&C) Wall External Pressure Coefficients,GCp: Corner Zone No GCp Zone 4 Neg.= -0.97 Fig.30.4-1 GCp Zone 5 Neg._ -1.23 Fig.30.4-1 qz=0.00256'Kz'Kzt'Kd°V"2'0.6(alowable) Wall Pressures for Design: Kz qz GCp F(psf) h 0.7 8.78 -0.97 = 9.6 0-15 ft Overall Letter Width= 8.44 ft Overall Height= 1.50 ft Area= 12.66 112 Standoff= 0.00 in Raceway Height= 3.00 in Raceway Behind Letters Sign Area and Loading: Sign Above Canopy Width, Height to Height to %solid Area,fie Wind Force,lb ft bottom.ft top,ft load,psf 8.44 13.75 15.00 30% 3.16 9.6 30 letters 8.44 13.75 13.75 0% 0.00 9.6 0 standoff 8.44 13.50 13.75 100% 2.11 9.6 20 raceway E= 50 V,= 30 lb V2= 50 lb arm,= 7.50 in =(15'-13.75')12'12 0 Mi armz= 1.50 in =(13.75.-13.5')/2'12 M,= 225 in-lb =30'7.5" rg Mz= 345 in-lb =225in-Ib+(30'3+20'1.5") 6 0 Est.Dead Load= 16 lb (assumed at 3 psi) /o /, Ti Fastener Check: (raceway to supporting structure) Fastener Type:Self-drilling Screws Mtotal= 345 Iin-lb V10 = 50 Ilb Ttma= 0 lb sign is attached above struulure) Fastener Quantities: Columns= 3 (min) Rows= 1 total fastemers= 3 couple distance= 1.00 in T= 115 lb per fastener =(345in-lb/1"+171/(3) V= 17 lb per fastener =50Ib/(3) Fastener into:Steel Fastener Type:Screw Mat.Gauge:0.125 Mat.Thickness:) 0.125 in Fastener Size: 0.25 Tc= 514 lb Vc= 693 lb 0.25 n 1.00 0K Use minimum 3 0.25 Screws along sign connection 8'S 1/4" - I =' 7 1---1E--1)'. (-16`) i-v-7. } � --- - , - <__ __ ,. .11 Project Name Everbowl Canopy Signs Project# 221267 MILLER_ ENGINEERS Location 11858 SW 72nd Avenue, Tigard, OR ENGINEERS Client Meyer Sign Company of Oregon 9600 SW Oak St 0400 503.246.1250 CJM J,tf 8/22/2022 1 Of 4 Portland,OR 97223 ! miller-se.com By Ck'd Date Page Scope of work is for the design of the sign support arms and their attachment to the existing structure. Input Data:ASCE 7-16 Maximum Sign Height(h)= 15.00 ft Wind Speed,V= 98 mph Exposure Category= B Topo. Factor, Kzt= 1.00 Direct. Factor, Kd= 0.85 Effective Area,Ae= 2.38 ft2 (Area Tributary to C&C) Wall External Pressure Coefficients, GCp: Corner Zone= No GCp Zone 4 Neg. = -0.99 Fig.30.4-1 GCp Zone 5 Neg. = -1.26 Fig.30.4-1 qz=0.00256*Kz*Kzt*Kd*V^2*0.6(allowable) Wall Pressures for Design Kz qz GCp F(psf) h 0.7 8.78 -0.99 = 9.6 0- 15 ft Sign Area and Loading: Free swinging? No Sign located below support Width= 3.00 ft Height= 0.79 ft %solid= 100% Area= 2.38 ft2 =3'*0.79'100% Lateral Force,Vy= 23 lb =2.38*9.6 Dead,Vz= 10 lb(estimated at 4pst) Horizontal offset= 0 in(center of mass to center of support,oop) Vertical offset from mount= 18.0 in Moment arm(vert.)= 1.90 ft =0.7972+18"/12 DROP ARM(S): Number of Arms= 2 %trib.to single arm= 50% Moment, My= 22 ft-lb per arm =(23*1.9'+10*0712)*50% Shear,Vx= 12 lb per arm =23*50% Tension,Tz= 5 lb per arm = 10*50% 1/4"DIA.BOLT,TYP. Use 6061-T6 2x2x0.125 aluminum tube See •a'e after next for calculation. EXISTING STEEL CANOPY MEMBER 2x2x1/8 ALUM. TUBE,TYP. m Project Name Everbowl Canopy Signs Project# 221267 ' MILLER CONSULTING 11858 SW 72nd Avenue, Tigard, OR 1111 ENGINEERS Location Client Meyer Sign Company of Oregon 9600 SW Oak St#400 503.246.1250 GM l 8/22"2022 2oi4 Portland,OR 97223 miller-se.com By Ck'd Date Page DROP ARM CONNECTION(S): Forces at base plate(s): Moment, My= 22 ft-lb per arm Moment, Mx= 0 ft-lb per arm Shear,Vx= 12 lb per arm Tension,Tz= 5 lb per arm Number of fasteners: #of rows= 1 #of columns= 1 Total number of fasteners= 1 per connection Forces on anchorage: 0 Vertical spacing= 1 in,from fastener to edge of plate Tension,Tx= 276 lb per fastener =22`12/1"/(1)+12/(1) Shear,Vz= 5 lb per fastener =51(1) Try 1/4"dia.bolts Tallow= 1380 >276 OK Vallow= 740 >5 OK Comb.Cap.= 0.21 < 1.00 OK (Use 1/4"dia.bolts ' Project Name Everbowl Canopy Signs Project# 221267 �® MILLER CONSULTING ENGININEEERSRS Location 11858 SW 72nd Avenue, Tigard, OR E Client Meyer Sign Company of Oregon 9600 SW Oak St#400 503.246.1250 Portland,OR 97223 miller-se.com By CJM Ck'd Date 8/22/2022 Page 3 of 4 Aluminum Tube Design: Drop Ann Section Properties: b= 2 in d= 2 in t= 0.125 in Scx= 0.513 in' Scy= 0.513 In' A= 0.90 in' aer= 0.5 in =2'0.125'2 as,= 0.5 in =2"0.125'2 rx= 0.755 in' =SQRT(0.513/0,9) ry= 0.755 in' =SQRT(0.513/0.9) Is= 0.513 in° ly= 0.513 in° J= 1.026 in° Material Properties. Aluminum Grade: 6061-T8 Weld Filler Alloy: 4043 reaction does occur within 1'from welded area E= 10100 ksi Bs= 10.57 ksi Fcy= 15 ksi Ds= 0.03 Fty= 15 ksi Cs= 126.72 Weld shear cap. = 5897 psi(based on weld alloy strength) Bc= 16.22 ksi Dc= 0.07 ny= 1.65 Cc= 102.30 nu= 1.95 Bp= 18.25 ksi Cb= 1 Dp= 0.08 k1= 0.35 k2= 2.27 Bending: M,= 0 ft-lb Compression in Beams,extreme fiber(3.4.141 Lb,= 18.00 in Slenderness Limitations: Slenderness,S= 25 =(18'0.513)/(0.5'SQRT(0.513'1.026)) S1 S2 Fb,= 9091 psi 139 4088 lb,. 0 psi 0'12/0.513 Lb limit,(In)= 98 2891 0.00% Strong Axis: My= 22 ft-lb Stresses.psi: Lby= 18.00 in S<S1 S1<S<S2 S2<S Slenderness,S= 25 =(18'0.513)/(0.5'SQRT(0.513'1.026)) 9091 N/A N/A Fby= 9091 psi Weak Axis: fby= 515 psi=22'12/0.513 Stresses,psi: 5.66% S<S1 St<S<S2 S2<S 9091 N/A N/A Shear: V,= 0 lb Shear in Elements:(3.4.20) h= 1.75 in=2-2'0.125 Slenderness Limitations:(htt) Slenderness.hit= 14 81 $2 Fvy= 10400 psi 45 101 fvy= 0 psi=0/0.5 Strong Axis: 0.00% Stresses,psi: V,= 12 lb hft<S1 S7<h/l<S2 52<h% h= 1.75 in=2-2'0.125 10400 N/A N/A Slenderness,hit= 14 Weak Axis: Fv,= 10400 psi Stresses,psi: fv,= 24 psi 12/0.5 htt<S1 St<hlt<52 62<hit 0.23% 10400 N/A N/A Torsion= 0 ft-lb Am= 4 in' _(2.0.125)'(2-0.125) Nr= 0 psi=0*12/(2'0.125'(2-0.125)'(2-0.125)) Fv= 10400 psi 0.00% Tension:(3.4.1) T= 5 lb Ag= 0.90 in' Ft= 9091 psi,assumes that all element of the member are connected for tension ft= 5.6 psi 0.06% Combined Forces: 0.06 <1.00 OK lUse 6061-T62x2x0.125 aluminum tube i itEveProject Name rbowl Canopy Signs Project# 221267 MILLERCONSULTING ENGININEEERSRS Location 11858 SW 72nd Avenue, Tigard, OR E Client Meyer Sign Company of Oregon 9600 SW Oak St#400 503.246.1250 Portland,OR 97223 miller-se.com By OMCk'd Date 8�22/2022 Page 4 of 4