Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
Worldwide t co-fire.com ty�� Contacts wwwy Fire Protection Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers F Description described herein must be installed and sa maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright (TY313) and Pendent (TY323) standards of the National Fire Protec- x Sprinklers described in this data sheet Lion Association, in addition to the stan- are are quick response,standard coverage, dards of any other authorities having r d decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair i sprinklers designed for use in light or the performance of these devices. t` ordinary hazard, commercial occupan- des The owner is responsible for maintain- • such as banks, hotels, and shop- ing their fire protection system and ping malls. devices in proper operating condition. The recessed version of the Series N- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. a finished ceiling.This recessed pendent sprinkler uses one of the following: pf.�n I�le�- F �t • A two-piece Style 15 Recessed A s _ a r y Escutcheon with recessed adjust- ment Identification �` � r ment up to 518 inch (15,9 mm) from /�/ ° � the flush pendent position. Number(SIN) "' I • A two-piece Style 20 Recessed S Escutcheon with recessed adjust- N313 Upright5.6K, 1/2""NPT x merit up to 112 inch (12,7 mm) from N323 Pendent5.6K, 112""NPT . the flush pendent position. The adjustment provided by the Technical Temperature Rating Recessed Escutcheon reduces the 135°F (57°C) accuracy to which the fixed pipe drops Data 155°F (68°C) to the sprinklers m ust becut. 175°F (79°C) Intermediate level versions of Series Approvals 200°F (93°C) TY-FRB Sprinklers are described in UL and C-ULListed 286°F (141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved CE Certified Finishes kler guards and shields are described S rinkler: Refer to Table A in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL p and C-UL Listed as Corrosion-Resis- Recessed Chrome Plat d tcoh Brass eon: hitePlat Coated, tant Sprinklers. Maximum Working Pressure d Physical Characteristics Bronze 175 psi(12.1 bar) Frame 250 psi(17.2 bar)" Button Brass/Copper The maximum working pressure of 250 psi Sealing Assembly Stainless Steel w/TEFLON IMPORTANT (17.2 bar)only applies to the listing by Un- derwriters Laboratories, Inc.(UL). Bulb Always refer to Technical Data Compression Screw Bronze Sheet TFP700 for the"INSTALLER Discharge Coefficient Deflector Bronze WARNING"that provides cautions K=5.6 GPM/psir z(80,6 LPMlbar1 z) with respect to handling and instal- lation of sprinkl ersystems and com- ponents. Improper handling and installation can permanently dam- age a sprinklersystem orits compo- nents and cause the sprinkler to fail to operate in a fire situation orcause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components. *Temperature rating is ** Pipe thread connections per ISO 7-1 1 -Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 -Compression STYLE 15or20 3 -Sealing Screw ESCUTCHEON PLATE 112" 7/16"(11,1 mm) RECESSED Assembly 6 -Deflector DEFLECTOR* * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON "V \5 .�� 7/16" (11,1 mm) f 4 i NOMINAL 2" 0 (I MAKE-IN (50,8 mm) 2 2" III L 1-3/8" ��, (50,8mm) (34,9 mm) WRENCH 3 1 t 1 __ 1 FLATS 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. ----.- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- Criteria ble should be present. The diameter WRENCH of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) ��� Sprinklers are intended for fire protec- temperature ratings. lion systems designed in accordance II# t r with the standard installation rules rec- A leak-tight 1/2 inch NPT sprinkler jointshould be obtained by applying a min- ....) Appro d by the applicable Listing or imum to maximum torque of 7 to 14 ft.- Approval agency (such as, UL Listing lbs. (9,5 to 19,0 Nm). Higher levels of is based on the requirements of PAthe torque can distort the sprinkler Inlet %W 13, and FM Approval is based on the with consequent leakage or impairment PUSH WRENCH requirements of FM's Loss Prevention of the sprinkler. IN TO ENSURE Data Sheets).OnlytheStyle15orStyle ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF (57,2 mm) Torque sprinklers 7 to 14ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers { \ FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" Sprinklers must be installed in accor- (9,5±7,9 mm) 7 ` dance with the following instructions. Step A.After installing the Style 15 or }MOUNTING 1/8 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread I sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. FIGURE 4 Step B. Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench(Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4' DIA. ishing, slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in + FLUSH contact with the ceiling. 7 rl—j- Care and t 1,8.. Maintenance MOUNTING SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, Upright (TY313) and Pendent (TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8' (22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hay- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion,but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local - The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage, or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing, and maintenance of sion must be replaced. theirfire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- ofthe National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX � I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) WHITE( 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE PO YESTER010)" 15E 155°F(68°C) SIGNAL WHITE(RAL9003) 371 5.6K PENDENT(1/2-NPT) TY323 4 POLYESTER 175 175°F(79°C) *Use suffix"r for ISO 7-1 connection. 9 CHROME PLATED 20C 200°F(93°C) for example,77-370-4-175-I Eastern Hemisphere sales only 28E 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*)finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*)finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP.All rights reserved. t co TEFLON is trademark of The DuPont Corporation. F,ry Protection Pry(fUcts -` ' it I : 11 � .. S - r , n . �.. + * % lam" c, 41 Lt., Wt x. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size(Inches) 1" 1.1/4" 1-112" 2" 2-1/2" 3" 4" 6" 6 NPS(In.) 1" 1-114" 1.112" 2" 2.112" 3" 4" C:i 0.D.(in) 1.315 1.660 1.900 2.975 2.875 3.500 4.500 6.625 8.625 CA1.315 1.660 1.900 2.375 2875 3.500 4.500 I.D.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 "ct 1.049 1.380 1.610 2.067 2.469 3.068 4.026 LJJ Empty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3530 4.340 5.620 9.290 16.940 W 1.680 2.270 2.720 3.660 5.800 7.580 10.800 J Water Filled Weight(Ib/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 = 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 El 1.00 1.00 1.00 1.00 1.00 1.00 1.00 = Pieces per Lift 91 61 61 37 30 19 19 10 7 = 70 51 44 30 30 19 19 NLift Weight(Ibs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 t] 2,470 2,431 2,573 2,306 3,654 3,024 4,309 Lift Weight(Ibs)24'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 (h 2,822 2,778 2,872 2,635 4,176 3,456 4,925 Lift Weight(Ibs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 2,940 2,894 2,992 • 4,350 3,601 5,130 SCHEDULE 10 & 40 ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed (US&Canada) and FM approved • We have the most stocking locations in the industry, for best delivery and availability • ASTM A135 and A795 Type E,Grade A Certified • Plain end or roll groove • Complies with NFPA-13, 13R and 14 • Eddy Guard II-bacterial-resistant internal coating _ • Industry-leading hydraulic characteristics Custom length options • CRR of 1.0 and greater • Hot dipped galvanization - • All pipe NDT weld tested • Reddi-Pipe'red or black pipe eliminates field painting • Compatible for use in wet,dry, preaction and deluge sprinkler systems Exclusive maker of Reddi'I'Ipeiiiik- ® RED OR BLACK PAINTED PIPE. F The only maker with EPDs (to help earn LEED points). °` 114i7j A 4,.... ► CERTIFIEC C US LISTED lell>" O11FS4 ..... rw....+.....v APPROVED IFPA *.'" •^ 4�. 4* - 800.325.446 11 MULL MOOSE ' - �: il..h�: BullMooseTube.com Xil , Ductile Iron Fittin:s-Class 300 UL FM LSr;zu, I c (� us LISTED APPROVED Fig. 35E 3 - 90° Elbow A Size A Packing Weight in Part Number in Inner Master lb �yy 1/2 35E 3004 1 13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 �j®% I 1-1/4 35E 3012 1.75 25 50 0.8 _ 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 90° Reducing Elbow A B Packing Weight ( B ) Sizein Part Number in in Inner Master lb 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 - 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 W 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 i A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1 45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-112 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 314 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2 16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2-39 2.60 6 12 2.5 Fig. .35F.3 - 45° Elbow Size Part Number A Packing Weight inin Inner Master lb 7 1/2 35F 3004 0.88 150 300 0.2 *ilk 3/4 35F 3006 0.98 80 160 0.3 -y 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 j��i 1-1/2 35F 3014 1.44 20 40 1.0 IA 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2,7 Fig. 35T 3 - Tee Size Part Number A Packing Weight in in Inner Master lb riuMll -A 1/2 35T 3004 1.13 80 160 0.3 V 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1I1------I 1-1/2 35T 3014 1.94 10 20 1,5 A A 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2 70 4 8 4.3 III SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.emithcooper.com � - Ductile Iron Fittin:s-Class 300 UL FM r ftt3'sU t nu3 t c (20uS LISTED APPROVED A Fig. 35CP3 - Straight Coupling with Ribs Size A Packing I Weight n Part Number n loner Master lb 0 . .. 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 1 0.7 2 35CP3020 2.62 15 30 12 2-112 35CP3024 3.00 9 - 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Size A Packing Weight in Part Number in Inner Master lb 1 x 1/2 35RC3010004 1.69 80 160 0.3 A 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35R03012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 - Hex Bushing Size Part Number A Packing Weight B inin Inner Master lb ' 1 x 1/2 35HB3010004 1,06 180 360 0.2 1 x 314 35HB3010006 1.06 180 360 0.1 i i 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 ' 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 4 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 "fte.1 If Fig. 35SP3 - Square Head Plug Size part Number A Packing Weight i❑ in Inner Master lb , a?- r 1/2 35SP3004 0.94 600 1200 0.07 A 3i4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 358P3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0,4 2 355P3020 1.50 45 90 0.6 Fig. 3.5U3 - Union with Brass Seat Part Number A Packing Weight �, Sizeinin Inner Master lb �,4.1 1 35U 30102 2.19 20 40 1.0 I- 1-1/4 35U 3012 25p 15 30 1.2 I 'I 1-1/2 35U 3014 2.62 10 20 1.7 ail2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX 6323) 890-4156 • www.smithcooper.com Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) @TDLca Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) UL us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200- 1/2"(15mm)thru 8"(200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function:Forfire sprinklerand othergeneral piping purposes.Knurled \ • swivel nut design permits hanger adjustment after installation. Features: • (1/2"' (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe (,.. typesand protectCPVCplasticpipefrom abrasion.Captured design " ' °f keeps adjusting nut from separating with hanger. Hanger is easily - B installed around pipe. A For hanger with non-captured nut order Fig. 200S. • (21/2"(65mm)thru 8"(200mm))Spring tension on nut holds it securely in r hanger before installation.Adjusting nut is easily removed. 1'� f Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (20omm)) =' Fig.208-Vz28g-%d in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fig.200-2r2to20-8 Factory Mutual Engineering Approved (FM)(3/4" (20mm)thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization SocietyANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature:650°F(343°C) .x> 'Mil!" Finish: Pre-Galvanized. Stainless Steel - materials will be supplied with(2) hex nuts w. . > } in place of a knurl nut. Order By: Figure number and pipe size " E . Designed to meet or exceed requirements of FM DS 2-0. ,, Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.W1.1100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) ,N. 200-112 1/2" (15) 3r8'-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-314 3l4" (20) 318"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 'i J' 3 200-1 1" (25) 3Is"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-1114 1114" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) ) 200-1112 1112" (40) 3IS" 16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3I8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 1,, 200.2112 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200.3112 3112" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 318"-16 73/8" (187,3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (1581) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (1714) 73 (33.4) 200-8 8" (200) 112"-13 13118" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by F:T*N Threaded Accessories B3205-Threaded Rod(right-hand threads-both ends)(TOLCO Fig.103) - B3205L - Threaded Rod (right & left hand threads) /TLC Specify Length Size Range: 3/a"-16 thru 3"-4 rod r Material: Steel . Function: Recommended for use as a hanger support in hanger assemblies. TL l Rod is threaded on both ends with right hand threads of the length shown.Also „at1-- A available with left and right hand threads-specify Fig.B3205L when ordering. -Thread Size Maximum Temperature: 750°F (399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL bau'r 1343"ca rang (3y8•(;{ Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" ; (63.5) 730 (3.25) 572 (2.54) B3205112x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205 51ax'L' 5/8"-11 21/2 (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8x'1' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 83205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 83205-2x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" T (279.4) 49400 (219.73) 38687 (172.08) 83205-3x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) 4A Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/e"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length �� ),�� �� Material: Steel �, .--' 10�� CD _ � m Maximum Temperature: 750°F(399°C) ,, CD N Finish: Plain. Contact B-Line for alternative finishes and materials. ''- 2 o Order By: Part number, rod diameter and finish t• a Part No.-Size x Length Threads Recommended Load Approx.Nt.1100 Ft. A I K I-ig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 991/4"x length 20 240 (1.07) 12 (5.44) ATR 310"x 120 99-318"x length 16 730 (3.24) 29 (13.15) AIR 1/2"x 120 99 1/2"x length 13 1350 (6.00) 53 (24.04) ATR 518"x 120 995/a"x length 11 2160 (9.60) 89 (40.37) ATR 314"x 120 99-3!4"x length 10 3230 (14.37) 123 (55.79) ATR 7!8"x 120 99 7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised 4/28/2014 gLlne by IET•N VERTICAL MOUNT � _ SAMMYS® for Steel Product Features AILIIIIIIF IIIIIAIEIIIIIII no •Made with Teks®self-drilling fasteners- �re-dre1utred no pre-drilling required. . '' 6 •Install into steel range from 22 gauge- thicknesses. -- ------ -- 'C"+ .. •Saves time from traditional methods. ' .i Yam► E ;'„ •Reduces installation cost. f:Ks •Quick to install using the Sammy Nut _ Drivel with an 18V cordless drill/driver. 4 (-: '' Approvals Rod Part Screw Ultimate UL Test Load Min Max Box Case { Size Number Descriptions Pullout(Ibs) Load On) NisThick Thick (try Qty tiitt,Pttl — 1/4" 8024957 DSTR 100• 1/4-20 x 1'TEKS 3 1510(20 ga.) .036"-20 ga 3/16" 25 125 114" 8025957 DST 100 1/4-14 x 1"TEKS 3 446 (20 ga.) 036"-20 ga 3/16" 25 125 1/4" 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970(16 ga.) .036"-20 ga 3/16" 25 125 114" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) 036"-20 ga 3/16' 25 125 1/4" 8030957 TEN 500 12-24 x 1-1/2'TEKS 5 3125(3/16') .181"-3/16' 112' 25 125 - -+ Q.i3 318" 8038957 DSTR 1* 114-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 036"-20 ga 3/16" 25 125 0.Q 3/8" 8037957 DSTR 1-112. 12-24 x 1-112"TEKS 5 1510 (3/161 1500 1475 .060%16 ga. 1/2' 25 125 c 3/8' 8039957 DSTR 516* 5116-18 x 1-1/4'TEKS 3 2200(20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446(20 991 #14 Black 970(16 ga.} .036'-20 ga 3/16" 25 125 Nut Driver `v 446 (20 ga.) Part#8113910 3/8' 8077525 DST 10-SS 114-14 x 1'TEKS 3 .036"-20 ga 3116" 25 125 970 (16ga.) 7.7.71 3/8" 8041957 DST 15 114-14 x 1-1/2"TEKS 3 446 (20 ga.) 35 , 970 (18 ga.j .036•-20ga 3/16° 25 125 3 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036'-20 ga 3/16" 25 125 970 (16ga) °'r 3/8' 8042957 DST 20 1/4-14 x 2 TEKS"3 446(20 ga) .036"-20 ga 3/16" 25 125 . .- 970(16ga.) ., 3/8' 8043957 DST 25 1/4-14 x 2-1/2"TEKS 3 446 (20 ga.) 970 (16ga.) 036"-20ga 3/16" 25 125 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 ga.) 970(16ga.) .036'-20ga 3/16' 25 125 "„,,T t .Q 3/8" 8045957 DST 516 5/16-18 x 1-1/4"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 1/8" 25 125 „s.;>.e, 0„,Q 3/8' 8046957 TEK50 12-24x1.112"TEKS 5 3125(3/16") 1500 1475 .187"-3/16 1/2' 25 125 _ 1/2" 8031925 DST 2,0 1/4-14 x 2"TEKS 3 446 (20 ga) .188"-3116" 1/4" 25 125 970 (16ga.) 3v 1 1/2' 8033925 DSTR1.0" 1/4-20 x 1'TEKS 3 1510(20ga.) .036"-26ga 3/16" 25 125 112" 8034925 DSTR 5.16' 5/16-18 x 1-114"TEKS 3 2220(20 ga.) 036"-20 ga 1/8" 25 125 1/2'" 8035925 DST 5.16 5/16-18 x 1-114'TEKS 3 1500(3/16") .125"-1/8" 1/8' 25 125 1/2' 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") .187"-3/16" 1/2" 25 125 #14 SW Red Nut Driver • 'Includes retaining nut Part#8114910 SAMMY Swivel Head° for Steel lns;,,!'s _ "',CAL LYa'id Product Features r 'hf. •Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hang plumb. •Accommodates 3-1/2 x 12 pitch. •Allows 17°deflection from vertical. II Rod Pa 'k Screw Ultimate UL Test FM Test Min Max Box Case C V 318" 8137957 SH-DSTR t" ti4 20 x 1" 3220 (3115') 1505 1475 035' 3.15 25 125 1- "Includes retaining nut (Does nal comply wdhROHSrequirements) #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit wwwsammysuperscrew.com 6 d ms \ / es