Loading...
Plans #10 Awg THHN 3/4'EMT or FMC Inverter Cade Ground#12 A Array of 9 modules and Black LI Gleierns t0wR 9 IQ7PLUS-72-2-US MIcrolnverters Red-L2 J8ox qIJ \ Green Ground\ P o it y ly Jj U PV FN J � I ��A Module Module #10 Awg THHN -9/4'EMT or FMC 1 ', and#12 Aw Array of 9 modules and Inverter kCableLl blnce 25 ft tt 91Q7PLUS-72-2-US Microinverters Black JBox Lt e r tic I�IL.,-IL.. \ Green Ground` \ A NEW . UiLDI NGl r lIVtS 11 !i it®�Y SOLAR Q J COMBINER vv Fv Module Module #10 Awg THMN 3/4'EMT or FMC nd#12 Grou in15 Array of 10 modules and Inverter cable �« 1121 101Q7PLU3-72.2-US MIcroinverters Black_IL�1Red Jgox 15A�--� 10A \ Green Ground\ e _•nJ Z- _Z 20A © o PV PV V Module Module CITY OF TIGARD I Approved plans REVIEWED FO CODE COMPLIANCE ✓hall be on job slt . Approved: [ ] OTC: [ l On Home Permit #: y''`,S-1?-°Z2-- a6y 77 OFFICE COPY LIABILITY Address: tl3)9 S1nl Putlykon \/a,lI r The City of Tigard and its Suite #: employees shall not be �� f responsible for discrepancies By: .14- Date: 21 22 which may appear herein. VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT 107 Microinverters per branchBASED ON CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DOCUMENTS AND OTHER Page 1 of 2 DATA SHALL NOT PREVENT Job: Address: Current(A) 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10 11 12 13 14 15 16 THE CODE OFFICIAL FROM REQUIRING THE CORRECTION PNA s30 Matthew,Stacy Paragano 13309VRise(V) 0.03 0.08 0.16 0.26 0.39 0.55 0.73 0.94 1.17 1.43 1.71 2.03 2.36 2.73 3.12 3.53 Rev. SW Pumpkin Valley Terr. OF ERRORS. ORSC 105.4 Beaverton,OR 97007 VRise(%) 0.01 0.03 0.06 0.11 0.16 0.23 0.30 0.39 0.49 0.60 0.71 0.84 0.99 1.14 1.30 1.47 AM PROSTAT ELECTRIC&SOLAR AC disco&PGE Meter grouped on exterior wall of home less than 10'apart Utility Meter e m=9�© MAIN U. 225A SqD(HOM) #8 AWG THHN In 3/4"EMT or FMC 60A 200A Ground #10AWG AC Distance 5' DISCO SIN On Home In Home #8 AWG THHN in 3/4'EMT or FMC Ground #10AWG Distance 5' Inverter Specs: Manufacture:Enphase NEC 690.54 AC Point of Module:IQ7PLUS-72-2-US Interconnection Max Output Current: 1.21A Rated AC Output:33.88 Amps Nominal Output Volts: 240V Total number of Modules: 28 Nominal AC Voltage: 240 Vac Output Frequency: 47Hz-68Hz System Size: 10.78 kW Output Volt Range:211V-264V New Solar System 240Vac Voltage Drops Description Current(A) Wire Size(Awg) Distance(feet) Percent(%) PV Module Ratings Trunk Cable 0.60 Manufacture: Mission Solar Model#:MSE385SX5R Trunk to Combiner 12.10 10 20 0.24 Open-Circuit Voltage: 45.03V Operation Voltage: 36.93V Combiner to AC Disco 33.88 8 5 0.11 Max String Voltage: 1000V Operating Current: 10.42A Page 2 of 2 AC Disco to Main 33.88 8 5 0.11 Short-Circuit Current: 10.97A Job: Address: Max Series Fuse: 20A PNWO30 Matthew,Stacy Paragano Maximum Power(STC):385W Rev: 13309 SW Pumpkin Valley Terr. Total 1.06 Power Tolerance: +3W Beaverton,OR 97007 AM PROSTAT ELECTRIC&SOLAR Plot Spans Weight of solar <4.5 lblsgft Spans comply with 2308.7.2 Engineered Trusses 6:12, single layer comp roof SW Sabrina Ave Home — c 3 48' Elevation 212"Section 3111.4.8.1 <18"Section 3111.5.3.5 driveway -i m 0 m / 250 76' � 3i� 26' Ground to eve Ground to peak Utility Meter Combiner AC Disco Main Panel Page 1 of 3 Job: Address: PNW930 Matthew, Stacy Paragano 13309 SW Pumpkin Valley Terr. Rev: Beaverton, OR 97007 AM PROSTAT ELECTRIC & SOLAR Detail K >_12" Section 3111.3.4.8.1 (ridge) n e a 36" Pathway Section 3111.3.4.8.1 (pathways) 3 Pathway Section 3111.3.4.8.1 (pathways) ❑ a ❑ ❑ sun-ye1 7 " 0 Suneye Legend (degrees): 1. Tilt = 25 Azimuth = 180 Solar Array Setbacks: z12" along all horizontal ridges per Section 3111.4.8.1 Page 2 of 3 36" Pathway ridge to eve per exeption 1.2 Section 3111.4.8.1 Job: Address: Solar Array Coverage: PNW930 Matthew, Stacy Paragano Solar Array Attachments: Solar racking attachments per Solar Array sqft = 599 Rev: 13309 SW Pumpkin Valley Terr. 3111.3.5.3.3 24" OC within 3' of edge hip eve or ridge, 48" Roof Surface sqft = 2040 Beaverton, OR 97007 OC elsewhere Solar Array covers 29% of roof surface AM PROSTAT ELECTRIC & SOLAR Comp Roof Attachments spaced so that 2x framing 24" Max on Center no point load exceeds 50 lb Solar Pane 1 £ 4.5PSF max�---..„ .... Racking Details: Panel connecte Manufacturer= Iron Ridge to rails with 1 connector Model = XR100 for each 8 Sq feet or less per rack manufacturer's specs Attachment Details: / _ t Manufacturer= Iron Ridge Aluminum Rails to alternates Model = FlashFoot2 roof framing 4' OC max. • Two rails per min. per panel . r--7"-- -"-----"--"-" ."-"1"... - - l I Panels 41.1"X 75" aprox. 2X joist/truss to meet Oregon Solar code span requirements 12" Page 3 of 3 M`?X Job: Address: Min ii"SS lag embedded 2"min 2 Layers or less center of framing member y PNW930 Matthew, StacyParagano of roof material 9 13309 SW Pumpkin Valley Terr. lashed and sealed Rev: Beaverton, OR 97007 roof penetration AM PROSTAT ELECTRIC & SOLAR MSE PERC 66 �•161 .3 MISSION SOLAR W, ENERGY Positive Power Tolerance Class leading power output -0 to +3% Tr, e American Qa ity TrLc American Brand Mission Solar Energy is headquartered in San Antonio, Texas where we manufacture our modules.We produce American,high-quality solarmodules ensuring the highest-in-class power output and best-in-class reliability.Our product line is tailored for residential, commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations,proving excellent performance over the long term. Demand the best. Demand Mission Solar Energy. Certified Reliability • Tested to UL 61730&IEC Standards • PID resistant • Resistance to salt mist corrosion Advanced Technology • 6 Busbar • Passivated Emitter Rear Contact • Ideal for all applications Extreme Weather Resilience • Up to 5,400 Pa front load&3,600 Pa back load • Tested load to UL 61730 • 40 mm frame BAA Compliant for Government Projects FRAME-TO-FRAME WARRANTY • Buy American Act • American Recovery&Reinvestment Act Degradation guaranteed not to exceed 2%in year one and 0.58%annually from years two to 30 with 84.08%capacity guaranteed in year 25. For more information,visit www.missionsolar.com/warranty • ,234 CERTIFICATIONS x+�� ` B ,s ' 25 r a E HE a YEAR t IN THE USA 1� ' C EC C J us If you have questions or concerns about LISTED certification of our _� products in your area, please contact UL 61730/IEC 61215/IEC 61730/IEC 61701 Mission Solar Energy. C-SA2-MKTG-0027 REV 2 05/05/2021 www.missionsolaccom 1 info@missionsolaccom Class Leading 375-385W MSE PERC 66 BASIC DIMENSIONS ELECTRICAL SPECIFICATION [UNITS:MM/ ] PRODUCT TYPE MSE SXSR( -=Pm„) Power Output P. W° - 380 385 rI 1 l °"° I Module Efficiency % 18.8 19,1 19.3 IIIIIIIIIIIIIII11IIV��VIIIII111111111111I Tolerance % 0/+3 0/+3 0/+3 IIUNIIIIIIIIIIIIIIIIIIIII I111111IIIIII �v Short Circuit Current V 10.85 10.91 10.97 IInIIIIIIIIIIIIIIIIrIIIIIIillllll IIIII[ Open Circuit Voltage V° A 44.64 44.64 45.03 IIIIIIIIIIII IIIIII!.IIIII IIIIIIf IIIIII •..,A Rated Current ,m° V 10.26 10.34 10.42 IT Rated Voltage Vm° V 36.56 36.75 36.93 IIIIILIIIIIIIIIILIIIIIIIIIIIIIIIIIIII Fuse Rating A 20 20 20 ° IIIII:IIIIILIIIIIIIIIIIRIIIIIIIINIIII a �a �' System Voltage V 1,000 1,000 1,000 IIIIIIIIIIIIOIIIIIIIIIIHhIIIIIIIIIIII IIIIIIIlIIIu!IIIIIIIIIIIDIIIIIIIIIIIIIi TEMPERATURE COEFFICIENTS 111111111111111131011111111111 Normal Operating Cell Temperature(NOCT) 44.43°C(t3.7%) !IIuOIIIIIIIIIIIII IIIIII IIIIIIIIIIII Temperature Coefficient of Pmax -0.361%/°C 11110111111111111.111111111111111111 Temperature Coefficient of Voc -0.262%/°C Temperature Coefficient of Isc 0.039%/°C FRONT VIEW SIDE VIEW REAR VIEW OPERATING CONDITIONS CURRENT-VOLTAGE CURVE Maximum System Voltage 1,000Vdc MSE385SXSR:385WP,66 CELL.SOLAR MODULE Operating Temperature Range -40°C(-40°F)to+85°C(185°F) Current-voltage characteristics with dependence on irradiance and module temperature Maximum Series Fuse Rating 20A Cells Temp.=25°C Fire Safety Classification Type 1 12 Incident lrrd.=1000 W/m2 Front&Back Load Up to 5,400 Pa front and 3,600 Pa (UL Standard) back load,Tested to UL 61730 to Incident lrrd.=800 W/m2 Hail Safety Impact Velocity 25mm at 23 m/s Q Incident lrrd.=600 W/m2 w MECHANICAL DATA P-type Solar Cells P- a mono-crystalline silicon Incident 2 t]1 a Irrd.=400 W/m Cell Orientation 66 cells(6x11) Module Dimension 1,907mm x 1,044mm x 40mm Incident lad.=200 W/m2 z Weight 22 kg(49 lbs.) o Front Glass 3.2mm,tempered,low-iron,anti-reflective 0 in an an 40 Frame Anodized VOLTAGE(V) Encapsulant Ethylene vinyl acetate(EVA) Junction Box Protection class IP67 with 3 bypass-diodes CERTIFICATIONS AND TESTS Cable 1.0m,Wire 4mm2(12AWG) IEC 61215,61730,61701 Connector Staubli PV-KBT4/611-UR and PV-KST4/611-UR, UL 61730 MC4,Renhe 05-8 CE C C ® uS SHIPPING INFORMATION e G Container Feet Ship To Pallet Panels 380 W Bin - - - LISTED 53' Most States 30 780 296.40 kW Double Stack CA 26 676 256.88 kW PALLET[26 PANELS] Mission Solar Energy Weight Height Width Length 8303 S.New Braunfels Ave.,San Antonio,Texas 78235 1,274 lbs. 47.56 in 46 in 77 in www.missionsolar.com I info@missionsolar.com (572 kg) (120.80 cm) (116.84 cm) (195.58 cm) Mission Solar Energy reserves the right to make specification changes without notice. C-SA2-MKTG-0027 REV 2 05/05/2021 www.missionsolar.com I info@missionsolar.com Data Sheet Enphase Microinverters RegIon. AMFRICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro' IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+Microinverters integrate with the Enphase IQ Envoyy', Enphase IQ Battery", and the Enphase Enlighten"" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling ------— • Built-in rapid shutdown compliant(NEC 2014&2017) t Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules mommille • More than a million hours of testing - • Class II double-insulated enclosure • UL listed e,ENPHASE _,- " F b: Smart Grid Ready x *x • Complies with advanced grid support,voltage and 177, pi frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. nn, E N P H A S E • To learn more about Enphase offerings,visit enphase.com e Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) lQ7-60-2-US 1Q7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module lsc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter 10 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/ranges 240 V/ , 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms • Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6°i° 97.5% 97.3q° • CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q DCC-5 adapter) • Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httcs:llenohase.com/en-us/suo0ort/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com e EN PHASE ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or serece names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-01-06 IRONRIDGE FlashFoot2 The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. - . *i •5cro y rr M,u Twist-On Cap "fix FlashFoot2's unique Cap design encapsulates ' the lag bolt and locks into place with a simple :*`i Three-Tier Water Seal twist.The Cap helps FlashFoot2 deliver FlashFoot2's seal architecture utilizes three superior structural strength,by aligning layers of protection.An elevated platorm the rail and lag bolt in a concentric r diverts water away,while a stack of rugged load path. components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-10o Wind-Driven Rain Test. a�gk�y Single Socket Size A custom-design lag bolt allows you to install FlashFoot2 with the same 7/16"socket size used on other Flush Mount System components. Water-Shedding Design An elevated platform diverts water away from the water seal. Installation Features B (A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. C-` B Rounded Corners Makes it easier to handle and insert under the roof shingles. A ; r C Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 FlashFoot2 1000 Traditional solar attachments have a horizontal offset between the rail and lag 800 FlashFoot ♦Leading Competitor bolt, which introduces leverage on the lag a aoo bolt and decreases uplift capacity. noo w ♦Low-Cost Competitor FlashFoot2 is the only product to align the D 200 rail and lag bolt. This concentric loading design results in a stronger attachment for o 1 2 3 the system. Rail-to-Lag Offset(in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code &ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27"Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 0 2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.0 ,��_ IRONRIDGE Flush Mount System , r e Built for solar's toughest roofs IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified eiAll components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. rClass A Fire Rating Design Assistant 6, .- Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 25-Year Warranty ® Entire system and components meet Products guaranteed to be free newest effective UL 2703 standard. of impairing defects. Datashe XR Rails C} XR10 Rail XR100 Rail XR1000 Rail Bonded Splices . ilk A - V ---......„.......A ... l A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding Clamps & Grounding O UFOs Stopper Sleeves CAMO Grounding Lugs -— ,, ,. Universal Fastening Objects Snap onto the UFO to turn Bond modules to rails while Connect arrays to bond modules to rails. into a bonded end clamp. staying completely hidden. equipment ground. • Fully assembled & lubed • Bonds modules to rails • Universal end-cam clamp • Low profile • Single, universal size • Sized to match modules • Tool-less installation • Single tool installation • Clear and black finish • Clear and black finish • Fully assembled • Mounts in any direction Attachments O FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware „_ -- .. — - Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Wind-driven rain tested • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • Mill and black finish • Secures 3/a"or 1"conduit • Clear and black finish • Assembled and lubricated Resources _ --_ ,I Design Assistant _ NABCEP Certified Training Go from rough layout to fully NABCEin Earn free continuing education credits, engineered system. For free. while learning more about our systems. .;o to IronRidge.com/design :ao to lronRidge.com/training ` -t c 2018 IronRidge,Inc.All rights reserved.U.S.Patents:#8,695,290;#9,819,303;69,865,938;Others Pending.Version 1.60 ,��®