Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT COMMUNITY DEVELOPMENT Permit#: MEC2022-00815 Date Issued: 10/12/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S135CA00902 Jurisdiction: Tigard Site address: 11353 SW GREENBURG RD C Project: Quail Court Apartments Subdivision: None Lot: None Project Description: New mini split heat pumps:(1)in unit C, (1)in unit D,and (1)in office building E. Contractor: ROBBEN& SONS HEATING INC Owner: QUAIL COURT APARTMENTS LLC 2214 SE 8TH AVE 3570 SW RIVER PKWY#2307 PORTLAND, OR 97214 PORTLAND, OR 97239 PHONE: 503-233-5841 PHONE: FAX: 503-238-8849 FEES Specifics: Description Date Amount Type of Use: MF Permit Fee 10/11/2022 $176.51 Class of Work: ALT Type of Const: VB Plan Review 10/11/2022 $44.13 Occupancy Grp: R-3 Occupancy Load: 12%State Surcharge-Mechanical 10/11/2022 $21.18 Stories: Info Process/Archiving-Sm$0.50(up to 10/11/2022 $2.00 11x17) Project Valuation: $4,000.00 Investigation Fee 10/11/2022 $90.00 Investigation 12%State Surcharge 10/11/2022 $10.80 Fuel Air Handlers Fuel Types: Electricity Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: 1 Appliances Vent Fans: Vent Systems: Total $344.62 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules r, t Issued By: Permittee Signature: y ' Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the joh site at the time of each Inspection. Mechanical Permit Application FOR OFFICE USE ONLY' C. of Tigard - Received „ t `J ¢ii...tl ty� Permit No.: '+,•y�^' ,�/'' 13125 SW Hall Blvd.,Tigard,ORM7223 4 9 L. �I V Y )/ "' J /" �T 1� �� to-. Rview Phone: 503.718.2439 Fax: 503.598.1960 Date/Bey: C],.S ,-_)2 ---17 Other Permit: T I G A R D Inspection Line: 503.639.4175 S E P 6 1' - Date Ready/By: km: ® See Page Z For Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITY OF TIGA_R_ AA IA F ,,,_,,!,'_1..!. .Y ...� t3 .86. r li S. }E � g rva aliir». .$ 1 l: IJI., ..sw.:h 9-�G:.l di,!" 41;dA4 +'' f)1J ,� ° 9t3s1+ .�, ._:. '. "' ��-; „ t , ram- `� r� , , Mechanical permit fees*are based on the value of the work 0 New construction Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition El Other: mechanical materials,equipment,labor,overhead,and profit. §=l mIl.,, .l.` Ir .'+.`_ i. ,, ,. ..: Value:$ 14 POO ❑ 1-and 2-familydwelling kli ❑Commerciallindustrial ❑Accessory building For special information use checklist Multi-family ❑Master builder ❑Other: Description Qty. I Ea I Total � d !-.. x, -P It m-sE a" u t = Air c nditt oling: .. ..<.. °. 22 - -, - .� , s ,. ems. Air conditioning 46.75 Job site address: kv5s3 SW C'NC«.' ur' Re\ Furnace 100,000 BTU(ducts/vents) 46.75 City/State&ZlP: i 1 n�rck o 0. R-12 Z4 Furnace 100,000+BTU(ducts/vents) 54.91 1 Heat pump 61.06 Suite/bldg./apt.no.:La f)i E Project name: e 1 „ r Ductwork 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other. 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 'Pt, dica sti °%91 a "' Gus fireplacelmsert 33.39 `" v T{�'<.�3' µ, ss �arw�«m .. n r+ , `�ha �_: a �r. •_ Flue vent for water heater or gas Zlns N.‘ her - 9l3fv. t fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 r , �� �-� Other. 23.32 , i ill y `� Environmental exhaust and ventilation: Name: Qum;, Gk A--a`l. _._�C_n IEJ Range hood/other kitchen �� equipment 33.39 Address: 1 1553 Sw C,ree tl burg iZc1 .- 6 Clothes dryer exhaust 33.39 City/State/ZU': 1 I qe�d 02 G 7 ZZ(` Single-duct r hn rst(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax: ( ) Attic/crawispace fans 23.32 „-:;4a '".m,-sue . ,:i a a ,�4, 41,7 i� �r" 1,,, cre. ... Other: 23.32 Fuel piping: Business name: 9,oblloatn sons �,,,�[D�.�r� . Z n C _� - J $14.15 for first four;$4.03 for each additional Contact name: priAnan Furnace,etc. , Gras heat pump Address: W2BCv SE 9 tat tr. At. . 1 O'1r wawsuspendedhmit neater City/State/ZIP:Cke.CY,Dake .► Ca, q 7 015 Water heater Phone:Fjc ) _b ,S ( Fax::( ) Fireplace Range E-mail:annan 6) rOblse."04. Y44 SC1AS.COM Barbecue ; ` - £- ', ' 4 " t ',.` f Clothes dryer(gas) Business name: O _en Jr SAS µ.ea atoi e Other. Address: 15000 S(, P I A226 10q �» Subtotal City/State/ZIP:CI 3 ol� q70 i 5 Minimum permit fee($90.00) Phone:S0 Z. 9B, C1 ( ) Plan review(25%of permit fee) �!) 3 5 v�{l Fes' State surcharge(12%of permit fee) CCB lie.: y842,4 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-CCounty hBuildin Industry stry Service Board Print name: NAG6,14„6„ 6G,3(Le,r Date:Q -ILO's Z.L I:lnuilding\PerrndsnMEC PermitApp_040 113.dac 44O-4 1 T(I 1/02/COM/w®)