Loading...
Plans (52) M EC2020-00682 ( 1/2 ) RMSED OFFICE COPY 1 RECEIVE® MAR 18 2021 CITY OF TIGARD KEYNOTES BUILDING DIVISION 1 MOUNT 6"X6"TITUS SOF GRILLE ON UNDERSIDE OF OVERHANG FOR EACH EXHAUST DUCT. MAINTAIN 3 FT .SINCE. .1969. CLEARANCE FROM PROPERTY LINES AND OPERABLE ec. OPENINGS,AND 10 FT CLEARANCE FROM MECHANICAL INTAKES. 2 GENERAL KITCHEN EXHAUST TO RUN CONTINUOUSLY.USE FAN TYPE EF-1 SET AT 40 CFM. ,09irhr 3 PROVIDE 24 HR TIMER FOR EXHAUST FAN TO BE USED FOR �` m,Surve %, WHOLE HOUSE VENTILATION.TIMER SHALL HAVE MANUAL AND AUTOMATIC CONTROLS. PROVIDE LABEL THAT READS: 702 JEFFERSON ST "WHOLE HOUSE VENTILATION(SEE OPERATING VANCOUVER,WA 98604 INSTRUCTIONS)." SEE TABLE ON M8.00 FOR RUNTIMES. PHONE: ONE: 360-852-8 46 4 BEDROOM SHALL BE HEATED WITH ELECTRIC UNIT HEATER E-MAL: infoCoackola.com PROVIDED BY ELECTRICAL CONTRACTOR. REFER TO WEB PAGE:w .Iackola.com MECHANICAL SCHEDULES FOR EXACT MAKE,MODEL,AND SIZE. 5 ROUTE REFRIGERANT LINES DOWN TO HEAT PUMPS LOCATED IN PARKING AREA ON LEVEL 1. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR PIPE SIZING. 6 MOUNT 12"X8"TITUS SOF GRILLE ON UNDERSIDE OF OVERHANG FOR OUTSIDE AIR INTAKE/EXHAUST AIR. MAINTAIN 10 FT.SEPERATION BETWEEN OPENINGS. 7 PROVIDE MOTORIZED DAMPER ON 12'x8"DUCT. INTERLOCK MOTORIZED DAMPER WITH OPERATION OF ERV-2. 8 PROVIDE 24"X24"GREENHECK ESD-635 LOWER FOR INTAKE AIR. I 9 TYPICAL FLUE/COMBUSTION AIR PIPE ROUTING FOR NATURAL HP-1 HP-1 110.1 HP-1 I GAS WATER HEATERS. HP-2 HP-2 HP-1 HP-1 I REVISION I I I I APPROVED I I i Lao 2� - g � (LOU SU' 7Z 1 I i I � o QI d o0 m _ I p�� o H0.-_---_—_—_----- 2' --_—_� �� V0 Q _.. I HP-3 �C/A TYP.4 I I 110.1 HP-1 _� HPC HP-1 HP-1 HP-1 EF-4 no 200 FLUE TYP.4cwo 9 I cS I YI l5 V � TRASH 110.1 HP-1 HP-1 HP-1 I 114 I ----^---------------------------------------------------------------------------------� SD'/12x12 - MAINTENANCE UPPER LOBBY ¢ AjJ RGl 45 SDl 35 0 SDI 2s Rr- 80 16S SDI 25 ® ^ 6"x6' 6-112X12 6"x6"/- 6• 12x12 - 1 1 �/ 6' 127112 BIKE ROOM RR I I ® I 116 107 I I 10"x8" - - - - - - - - 1 RG3 75 121, 8' - - - - - - - �� 10"x8' iii 6"x6•/— 6"x6• SHEET I IIIII III O 4--0 O IIIIII IIII O OSD6S"x6"/3o— 6 /12z212 I I COMP UTER ROOM 4--0 " " 12•x "O EF-1 EF-1 EF-1 4"0 RGl FCS 5 FC3 5 Q LEVEL 0 W VQV C PUNCOPY OI85051 lrml6flln51261300 TYPICAL UNIT UNIT2.1B UNIT 2. 6 EUIPMENf LAYOUT UNTT2'IA �"'B 112•x8" 10"x8• I I 30 112 4• 6" 12x12 6" 12x12 III 4-0 II II •0 DRAWN: MRC OFFICE Fc-1 S FC-- S CHECKED: A6W��OFFCV� 104 E 4 EUH-1 EUH-1 4 III 4 EUH-1 EUH-1 4 II II 4 EUH-- EUH-1 q 103 I 102 DATE: 06/12/2020 I II II II O �(7) JOBJI: 199102 L — — - - — — — — — — — — — — — — Lid u O O O REVISIONS: OO ARCH COMMENTS 1/24/2020 BID SET REVISIONS 3/13/2020 MASON INDUSTRIES, INC THIS DRAWING HAS BEEN REVIEWED FOR SEISMIC BRACING SHRED PROfFs OF THE FOLLOWING UTILITIES: �,y aOINEC' so ❑ SUSPENDED PIPING ,148 R 'r ❑ '�- THE INFORMATION CONTAINED HEREIN DUCTWORK ,jU IS PROPRIETARY. THIS DOCUMENT MAY NOT BE USED OR REPRODUCED O OREGON WITHOUT THE WRIITEN CONSENT OF ❑ SUSPENDED ELECTRICAL TRAY/CONDUIT 61, ,y 90 JACKOLA ENGR.BARCH.,P.C. WE HAVE DETERMINED THAT NO SEISMIC BRACING IS Kyoga z7,i9 Q` REQUIRED FOR THE ABOVE SYSTEM(S) BASED ON THE OHARNP REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON EXPIRES:lywno22 INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). OTHER RESPONSIBILITIES TAKEN OR IMPLIED WITH M WITH THIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 �uA\\lVl//�ILlll �ILIII �ILJII NOTES: L8EVEL 1 HVAC PLAN 1/ " = 1'-0" 6mmF�--- PIPER 0 4' 8' 16' :_ A L i C KEYNOTES 1 PROVIDE EXHAUST TERMINATION BOX(XVENT BOX OR EQUAL) WITH INDIVIDUAL BACK DRAFT DAMPERS FOR EACH DUCT. .SINCE. .1969. MAINTAIN 3 FT CLEARANCE FROM PROPERTY LINES AND rc. OPERABLE OPENINGS,AND 10 FT CLEARANCE FROM MECHANICAL INTAKES. 2 ROUTE EXHAUST DUCTS UP TO LEVEL 4 ROOF WITH 4" DIAMETER DUCT. CAP AT ROOF WITH BROAN MODEL 634 OR �'.4 EQUAL eh+trrh+re,SurvrYio9 Y"ac 3 GENERAL KITCHEN EXHAUST TO RUN CONTINUOUSLY.USE FAN TYPE EF-1 SET AT 40 CFM. 702 JEFFERSON ST 4 PROVIDE 24 HR TIMER FOR EXHAUST FAN TO BE USED FOR VANCOUVER,WA 98604 PHONE: 360-852-8746 WHOLE HOUSE VENTILATION.TIMER SHALL HAVE MANUAL FAX 360-852-8514 AND AUTOMATIC CONTROLS. PROVIDE LABEL THAT READS: E-MAIL: @j I"foackola.com "WHOLE HOUSE VENTILATION(SEE OPERATING WEB PAGE:w jackola.com INSTRUCTIONS)." SEE TABLE ON M8.00 FOR RUNTIMES. 5 BEDROOM SHALL BE HEATED WITH ELECTRIC UNIT HEATER PROVIDED BY ELECTRICAL CONTRACTOR. REFER TO MECHANICAL SCHEDULES FOR EXACT MAKE,MODEL,AND SIZE. O6 ROUTE REFRIGERANT LINES DOWN TO HEAT PUMPS LOCATED IN PARKING AREA ON LEVEL 1. REFER TO MANUFACTURER'S ----- ---- [KIF L - -- t, a � [ �IDr EF-1 INSTALLATION INSTRUCTIONS FOR PIPE SIZING. " ,3- -n_.+>�_a . .. a,Trot a .E_�c 9 � - 4"� < :: ;. 7 BOTH FAN COILS IN THE 3 BEDROOM APARTMENTS WILL BE O ® CONNECTED TO A SINGLE HEAT PUMP. EFl EU5 II ® EUH-1 5 I I EUH-1 5 I 3 41-0 FC-2 6 7 II EF-1 I� 11 . -. FC>_1 X-6> 4 UNIT2.1 IIIII O �FC-1 6 7 IIIIIII q Lzzz � FC-1 4"0 _ 3 3 4"0 UNIT 2.2 U NITII3 .2 TYPEA- 223Q�IX 5 4"0 1 203 L r UNIT 3.1 4.10 EUH-1 _ O6 7 FC-1 4 4D 204 IItL�� EF-1 RGI 150 8"x6" 5 - EUH-1 I � O EF-1 O lo*� 0 4 EUH-1 5 [SDI. 100 d Dp � II UNIT 2.1 FC-1 6 6 12x12 a O 22100_. O m I( 4.0 EF_1 UNIT 2.1 ...22D 4"SCI _ "0gEUH-11� �0"0 - UNIT2.ITYPEASIM.I10"x10" O LAUNDRY q 4� 202 d Q 205 FC-1 6 Q II "0 I I EF 1 COMMUNITY ROOM I-6 0 O EUH-1 ' RG1 150 210J 5 - - - 8"z6"/- II 10'x10'- nn 8x8' . - - 4"0 V!/ li 4--0 4"o L 8'x6 /-- ff _ - - - - `13RR RR ® Q I I SERVICE _ _ 218 219 8"/12x12 2 - S6" 12x12 x - 217 _ - a " 30"x10" 8"x8" i 3 00 4 0 r73) l3 4"0 STORAGE ELEC/IT �/ SHEET 3 4"ol l I I I I 205 206 4--0 4"0 LEVEL 2 HVAC � 1� �'Y/�.. /4) ! q � � + O O r EF-1 Ir O PLAN \ LL O � � �� � 4 EF-1 �d � 4�0 j ��4"� _ 4 114.E EF-1 4 4--0 II 4"{d L�EF 1 EF 1 I EF1 EF1IIH !I � II UNIT 1.1 -_ UNIT 1.1 __._. UNIT 1.1 ___- UNIT 1.1 Its UNIT IATYPE A UNIT 2.3 UNIT 2.3 M - I( 207 216 215 213 212 -- - 211 208 --- II II DRAWN: MGIC; 6 B II II O FC-1 - FC-1 6 CHECKED: ��� II EUH-1 5 5 EUH-1 DATE: 06/12/2020 -1 5 6'I'll, FC-1 j � � FC-1 � 6 FC-1 6 FC-1 � 6 FC-1 5 EUH-1 : 191102 JOB �I (EUH-2 5 0 ( EUH-2 5 EUH-2 5 0-- EUH-2, 5 EUH-2 5 O O # REVISIONS: ARCH COMMENTS 1/24/2020 MASON INDUSTRIES, INC BID SET REVISIONS 3/13/2020 CODE REVISIONS 11/24/2020 THIS DRAWING HAS BEEN REVIEWED FOR SEISMIC BRACING ,c9go PROp', OF THE FOLLOWING UTILITIES: o�g aGINEF SAO B B.2 C C,2 D ❑ SUSPENDED PIPING j>J1482ng — (� SUSPENDED DUCTWORK �c/%D QT OREGON THE INFORMATION CONTAINED HEREIN ❑ SUSPENDED ELECTRICAL TRAY/CONDUIT G IS PROPRIETARY. THIS DOCUMENT �.)y x'90.27 MAY NOT BE USED OR REPRODUCED WE HAVE DETERMINED THAT NO SEISMIC BRACING IS 'O P WITHOUT THE WRITTEN CONSENT OF REQUIRED FOR THE ABOVE SYSTEM(S) BASED ON THE ��NARMP JACKOLAENGR.&ARCH.,P.C. REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON EXPIRE6:12/30/2022 INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). NO OTHER RESPONSIBILITIES IS TAKEN OR IMPLIED WITH THIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 NOTES: Rml ❑ 2O LEVEL 2 HVAC PLAN 0 IV B 6 KEYNOTES 1 PROVIDE EXHAUST TERMINATION BOX(XVENT BOX OR EQUAL) WITH INDIVIDUAL BACK DRAFT DAMPERS FOR EACH DUCT. •SINCE. •t969. MAINTAIN 3 FT CLEARANCE FROM PROPERTY LINES AND "`- OPERABLE OPENINGS,AND 10 FT CLEARANCE FROM MECHANICAL INTAKES. 2 ROUTE EXHAUST DUCTS UP TO LEVEL 4 ROOF WITH 4" DIAMETER DUCT. CAP AT ROOF WITH BROAN MODEL 634 OR ay4 EQUAL. rRYurq 5ur9' 3 GENERAL KITCHEN EXHAUST TO RUN CONTINUOUSLY.USE FAN TYPE EF-1 SET AT 40 CFM. 702 JEFFERSON ST 4 PROVIDE 24 HR TIMER FOR EXHAUST FAN TO BE USED FOR VANCOUVER,WA 98604 PHONE: 360$5241746 WHOLE HOUSE VENTILATION.TIMER SHALL HAVE MANUAL FAX: 360-852-8514 AND AUTOMATIC CONTROLS. PROVIDE LABEL THAT READS: E-MAL: info@jackola.cam "WHOLE HOUSE VENTILATION(SEE OPERATING WEB PAGE:w jackola.com INSTRUCTIONS' SEE TABLE ON M8.00 FOR RUNTIMES. 5 BEDROOM SHALL BE HEATED WITH ELECTRIC UNIT HEATER PROVIDED BY ELECTRICAL CONTRACTOR. REFER TO MECHANICAL SCHEDULES FOR EXACT MAKE,MODEL,AND SIZE. 6 ROUTE REFRIGERANT LINES UP TO HEAT PUMPS LOCATED ON ROOF. REFER TO MANUFACTURER'S INSTALLATION O - INSTRUCTIONS FOR PIPE SIZING. 1 7 BOTH FAN COILS IN THE 3 BEDROOM APARTMENTS WILL BE Vol -- - --- - I Y'T` Ti'-i` � ` EF-1 a_io --- CONNECTED TO A SINGLE HEAT PUMP. - - I _ 4 EF-1 O EUH-1 O IIEUH-1 O I I EF-1 .- O 5 FC-2 6 7 EUH-1 III I EFl I IL-0 IFr 0 -1 6 II41-0 - - 11 "' - - - - - — 0� 4 "0 UNIT o.l II -_. - 4"0 [ n II a II 0 II— II �u FC 1 I =i II 3 — 321 - __-.--- 4.0 = _ = =j11 II II - E� pWWy 3 zxs) OL1 v 3 6 7 FC-1 -- UNIT 3.1 EF-1 � 4 RGI 75 O ® O 6"x6"/— - EUH-1 EUH-1 5 ,_ � • 0 EF-1 00 0 EUN-1 __ --- -- I II - L SD1 100 FC-1 6 _ • 8 2x12 �1 =1 moll l 03 ��----- U 3� l 5 EUH-1 '`• 4 1 FC- 4"0 - I I 1 1NTI x - - — — — i 8 Q I 4'0 - UNIT 2.1 TYPE A II II I I EUH-1 O LAUNDRY 302 Q II 4'� 5 - —_ _ 305 0 FC-1 6 ` 5 EUH-1 EUH-1 S S EUH-1 EUH-1 5 I EF-1 EUH 1 5 (- 4' 6 FC-1 �'j 4" EUH-1 - - - � — � 4-09 ■1 - - E'-! �_.. S'k8' gb�• 50 I4.0L II J 5 -_-. -- _ _. . I I IRGIS STORAGE .._..UNIT 2.1 UNRz.II j 1 [ 1 1 317313 - I�q•� 310 S8. 12X1.!_IttRm !_�.1, I. 7 !-<� E. �P Al7.tl� 1.M : � 6 Arl- wiam ii#311 , lam fes_ I! k ARE.:_ I 131113311D 4.0 �I 4"0 - -- _ ... STS ELEC SHEET �O OIIti lia� II 114�� LEVEL e') HVAC --� UNIT 1.1 j ' PLAN 4"0 _ 4.0 _ _ — P C - - _ - - - 4 3 - 315 I � - 1 4"0 i 4'0 4'0 a r- 4 ( _-_ _ (4) UNIT 2.3 -- --- 307 �.. II II L3 LE--- I'I: EF-1 UNIT 1.1 EF-1 _— UNIT Ll EF-1 UNRLI EFl - _ UNIT 23 L DRAWN: MGIC - 316 314 312 311 ® _--41 � - EF-1 EF-1 II CHECKED: QG$C� II •0 a" II DATE: n _ O6I'92/�®?`�0 &F I n m n_ -- -1 6 EUH 1 3 EU►F3 6 FC-1 ti 11-14 I� O FC-1 6 FC-1 6 FC-1 6 FC-1 6 FC-1 - X06#: 98110 5 EUH-1 II EUH-1 s REVISIONS: ARCH COMMENTS 1/24/2020 U2 5I "�EUH-2 g BID SET REVISIONS 3/13/2020 - _ - CODE REVISIONS 11/24/2020 MASON INDUSTRIES, INC THIS OF THE FOLDRAWI HFOLI OWING UTIL TIES:NG HAS BEEN REVIEWED FOR SEISMIC BRACING a GINE Esso �R all, ❑ SUSPENDED PIPING ® SUSPENDED DUCTWORK / iG�� `�" - t THE INFORNAT RY.CONTAINED HEREIN AAA C.2 D D.2 E F F.1 � OREGON ISP ROT BE USED THIS DOCUMENT [:1 SUSPENDED ELECTRICAL TRAY/CONDUIT G MAY NOT BE USED OR REPRODUCED WR HOUT E WRITTEN 8 ARCHSENT P.C.OF WE HAVE DETERMINED THAT NO SEISMIC BRACING IS q R.27,Sq ACKOLANGR. REQUIRED FOR THE ABOVE SYSTEM(S)BASED ON THE ��OHARMP REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON EXPIRES: 12/30/2022 INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). NO OTHER RESPONSIBILITIES IS TAKEN OR IMPLIED WITH THIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 ml NOTES: LEVEL 3 HVAC PLAN 1 1/8" = V- KEYNOTES 1 PROVIDE EXHAUST TERMINATION BOX(XVENT BOX OR EQUAL)WITH INDIVIDUAL BACK DRAFT DAMPERS FOR EACH .SINCE. .1969. DUCT. MAINTAIN 3 FT CLEARANCE FROM PROPERTY LINES rc AND OPERABLE OPENINGS,AND 10 FT CLEARANCE FROM ,n MECHANICAL INTAKES. 2 ROUTE EXHAUST DUCTS UP TO LEVEL 4 ROOF WITH 4" DIAMETER DUCT. CAP AT ROOF WITH BROAN MODEL 634 OR EQUAL. th7Ure,Sumrli^%' 3 GENERAL KITCHEN EXHAUST TO RUN CONTINUOUSLY.USE FAN TYPE EF-1 SET AT 40 CFM. 702 JEFFERSON ST 4 PROVIDE 24 HR TIMER FOR EXHAUST FAN TO BE USED FOR VANCOUVER WA 88604 PHONE: 360-852-8746 WHOLE HOUSE VENTILATION.TIMER SHALL HAVE MANUAL FAX: 360-852-8514 AND AUTOMATIC CONTROLS. PROVIDE LABEL THAT READS: E-MAIL: iMoQackola.com "WHOLE HOUSE VENTILATION(SEE OPERATING WEB PAGE:vnaw.Jackola.com INSTRUCTIONS)." SEE TABLE ON M8.00 FOR RUNTIMES. 5 BEDROOM SHALL BE HEATED WITH ELECTRIC UNIT HEATER PROVIDED BY ELECTRICAL CONTRACTOR. REFER TO MECHANICAL SCHEDULES FOR EXACT MAKE,MODEL,AND SIZE. 6 ROUTE REFRIGERANT LINES UP TO HEAT PUMPS LOCATED ON ROOF. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR PIPE SIZING. 7 BOTH FAN COILS IN THE 3 BEDROOM APARTMENTS WILL BE CONNECTED TO A SINGLE HEAT PUMP. EF-1 4„0 O EF-1 n FC-2 6 7 EUH-1 5 '. EUH-1 5 II II EUH-1 5 I I EF- 05 F-5 EUH-1 FC-2 6 7 II EF-1 II 1 a„0 II Ih FC-1 6 II = _ _ = 4If UNIT 2.1 4--0 I 420 I I O UNIT 2.2 FC-1 6 O UNIT 3.2 a"0 421 FC-1 6 7 II 403 EUH-1 4"0 _ O �4: � EUH-1 5 = � UNIT 3.1 a -EF1 o RG1 100 JEUH-1 -_ o Q 5 I I EF-1 n 3 IIQ O II SD1x 100 EUH-1 - C-1 Qmo EUH-1 IUNIT IF6 2x12 0 OF419] EU n 4 '0 C UNIT 2.1 0I — 418 10I"x10" OnV�ItG— a II OS O O � EF-1 LAUNDRY UNIT 2.1 TYPE A no — FC-1 6 - 4"0 T ' -' -� ' 405 402 �j — -- — — 4';o 1 O5 EUH-1 EUH-1 5 5 EUH-1 EUH-1 5 10"x10" EF 1 npn� -11 O VO II II 4 6�F&l 6 FC-1 4" 5 8x8"— — RGI 150 FC-1 ( If o II Ef-1 EF1 I � EF-1 - II UNIT 2.1 - ----- II UNIT 2.1 6"x6" I00 FITNESS 58/12x12 I 413I "o 410 A0 I I I II S 100 6" x a 6” 12x12 raxf ue#v %, r� -Yh- `�w. --- - ._ "�`�, +€” �n Yb_S S 5. F�R ?. iYY'Se* r ¢ "3M z k ➢YA&Ci :u6%=.. 6'x6" SHEET 4110 -nu :-max s -i zr,. -F:W "i i .-Qm� 3 =.aye. woo .. (� IIII ___._- ,qI-�I WO � � --. ❑ � O Ila. 4"0 "� O4,-0 Iu I4 �0 q"� 3 q O _ LEVEL 4 N VAC II II II II UNIT 2.1 O UNIT 2.1 mL = V q��� � ® II a"0 II _ 4"0 0==4UO J4O .-' O O a 0Fc-1 6DRAWN: MG�C EF-1 EF-1 EF-1 EF-1 6 FC-1NIT 1.1 - UNIT 1.1UNIT 1.1 UNIT 1.1 UNIT 1.1 �IjlLL CHECKED: AG`8�7a16 assala alz auDATE: 06/12/2020 5EUH-1JOB#: 191102 6 FC-1 6 FC-16 FC-1 6 FC-1 6 Fc-1 REVISIONS: EUH-2 5 EUH-2 5 0-- EUH-2 S EUH-2 5 O® ® O BID SET COMMENTS 1/24/2020 BID SET REVISIONS 3/13/2020 ML� 01 CODE REVISIONS 11/24/2020 MASON INDUSTRIES, INC THIS DRAWING HAS BEEN REVIEWED FOR SEISMIC BRACING 6�ED PRopFs OF THE FOLLOWING UTILITIES: �°j"t; soy ❑ SUSPENDED PIPING /J r THE INFORMATION CONTAINED HEREIN 148n IS PROPRIETARY. THIS DOCUMENT B B C.2 SUSPENDED DUCTWORK MAY NOT BE USED OR REPRODUCED OREGON WITHOUT THE WRITTEN CONSENT OF ❑ SUSPENDED ELECTRICAL TRAY/CONDUIT �G JACKOLA ENGR.B ARCH.,P.C. OHAR WE HAVE DETERMINED THAT NO SEISMIC BRACING IS q�gDHAit REQUIRED FOR THE ABOVE SYSTEM(S) BASED ON THE �� M"* P REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON EXPIRES'12/x/= INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). OTHER RESPONSIBILITIES IS TAKEN OR IMPLIED WITH n /, ❑ /,1 O WITH THIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 NOTES: lJ V lJ LJ LEVEL 4 HVAC PLANE PIPER KEYNOTES 1 PROVIDE EXHAUST TERMINATION BOX INVENT BOX OR EQUAL)WITH INDIVIDUAL BACK DRAFT DAMPERS FOR EACH SINCE- •1969. AAA B B.2 C C.2 DUCT. MAINTAIN 3 FT CLEARANCE FROM PROPERTY LINES _ E-_ 1 AND OPERABLE OPENINGS,AND 10 FT CLEARANCE FROM �� MECHANICAL INTAKES. 2 ROUTE EXHAUST DUCTS UP TO ROOF WITH 4"DIAMETER DUCT. CAP AT ROOF WITH BROAN MODEL 634 OR EQUAL. 9rq_ ■_ �n0 3 GENERAL KITCHEN EXHAUST TO RUN CONTINUOUSLY.USE r'o'c•sa^"yio9, FAN TYPE EF-1 SET AT 40 CFM. 4 PROVIDE 24 HR TIMER FOR EXHAUST FAN TO BE USED FOR 702 JEFFERSON ST VANCOUVER,WA 98604 WHOLE HOUSE VENTILATION.TIMER SHALL HAVE MANUAL PHONE: 30"52-8746 AND AUTOMATIC CONTROLS. PROVIDE LABEL THAT READS: FAX: 360.852.8514 "WHOLE HOUSE VENTILATION(SEE OPERATING E-MAIL: intoQackola.com INSTRUCTIONS).' SEE TABLE ON M8.00 FOR RUNTIMES. WEB PAGE:w .jackola.com 5 BEDROOM SHALL BE HEATED WITH ELECTRIC UNIT HEATER PROVIDED BY ELECTRICAL CONTRACTOR. REFER TO MECHANICAL SCHEDULES FOR EXACT MAKE,MODEL,AND -- SIZE. 6 ROUTE REFRIGERANT LINES DOWN TO HEAT PUMPS LOCATED IN PARKING AREA ON LEVEL 1. REFER TO MANUFACTURER'S 41 INSTALLATION INSTRUCTIONS FOR PIPE SIZING. O 7 BOTH FAN COILS IN THE 3 BEDROOM APARTMENTS WILL BE CONNECTED TO A SINGLE HEAT PUMP. Ll EUH-1 5 I ". EUH-1 5 II ® FC-2 6 7 II 1 EUN-1 5 L 5 EUM-1 K-2 6 7 II EF-1 II _ O I 4"0 - 4 „ 1 FC-1 6 uNITz.l - - 4�0— n —F— 521 II " FC-1 6 FC- 6 - 7 UNIT 22 1 1 - II II - I I j 3 4V ___ 522 EUH-1 -_ ___ 3 � 4�� so3 UNIT 32 Ift EUH-1 5 13 .. ..,SLE<.. [C4 RG1 75 I UNIT 3.1 504 O � EF-1 6.,x6. EF-1� Q (� d EUH-1 I I I FC-1 6 4 S SDl 100 - O Q 00 ISS I I II UNIT 2.1 8' 2x12 S QO 0 O 520 _ -- -. _._ 3 I I G- -..�I EUN-1 0 II - — 4 o0 (!1� �-1 I II II EU O �j 1. -. ------ 4 Q UNIT 2.1 I I I - 4"0 I o II 519 O — F-1 - II II I I U O Q UNIT 2.1 TYPE ASIM. II 4"0 I I r_ :--'L_ — 74. �.-._ LAUNDRY rt x502 PC_1 6 L - II - 8. . "� -- 5 EUH-1 EUH-1 O O EUH- EUH-1 5 - - - � EF-1 � EUH-1 5 '" .. I I 11 6 FC-1 � II 6 FC-1 -� � O EUH-1 I $"a• _ II II 4- RGI 50 -_- EFI II - � EF-1 rJ _ s T>e I I - STORAGE - II __-UNIT 21 _- _' --- II LNIT2.1- - - _ -- 5 RGx6" 5 518 - II 512 � II Fun i P. 3 �- 3 SDS 100 - '. 8" 12x12 - I I I: 5 Y 4"06 SHEET f �O_.. _—O a.o �O 0 4.0 �O O — — J-4 3 114V e u 114"0 11 11 � O O 4.0 6.A— I11 001 6.A a0 O LEVEL 5 HVAC II PUN�( 4"0 u 4"� II II UNIT 2.1 11 . . UNIT 2.1 O 4 0 4"0 _ O 4"0 - S07 II EF-1 EF-1 1i II- O O UNIT 1.1 UNIT 1.1 UNIT 1.1 UNIT 1.1 UNIT 1.1 TYPE A FC-1 6 EF-1 EF-1 EF-1 EF-1 EF-1 - O �_1 DRAWN: Mfl(� 515 514 513 511 - 509 O O CHECKED: ARW 613 5 EUH-1 EUH-1 5 5 EUH-1 EUH-1 5 DATE: 06/12/2020 JOBS: 191102 6 FC-1 6 FC-1 6 FC-1 6 FC-1 REVISIONS: EUH-2 S EUH-2 5 EUH-2 5 EUH-2 5 EUH-2 S ARCH COMMENTS 1/24/2020 ---- - - - - -- BID SET REVISIONS 3/13/2020 -u -- MASON INDUSTRIES, INC CODE REVISIONS 11/24/2020 THIS OF THD DRAWING HAS BEEN REVIEWED FOR SEISMIC BRACING �\yt��GINE,Fsso ❑ SUSPENDED PIPING 148n ❑ SUSPENDED DUCTWORK ��.� /�• - ,- -- C OREGON THE INFORMATION CONTAINED HEREIN B B.2 D.2E ❑ SUSPENDED ELECTRICAL TRAY/CONDUIT 6. �q IS PROPRIETARY. THIS DOCUMENT 1 MAY NOT BE USED OR REPRODUCED - WE HAVE DETERMINED THAT NO SEISMIC BRACING IS X90/Q 27 OHARMP� WITHOUTJACKTHE WRITTEN CONSENT OF REQUIRED FOR THE ABOVE SYSTEM(S) BASED ON THE REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON ExrIREs 1v3orzoz2 INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). NO OTHER RESPONSIBILITIES IS TAKEN OR IMPLIED WITH THIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 NOTES: ml LEVEL 5 HVAC PLAN PIPER 1/8" = I'-0" o a' s' 15 KEYNOTES 1 PROVIDE EXHAUST TERMINATION BOX INVENT BOX OR EQUAL)WITH INDIVIDUAL BACK DRAFT DAMPERS FOR EACH •SINCE. •t969 DUCT. MAINTAIN 3 FT CLEARANCE FROM PROPERTY LINES ec. AND OPERABLE OPENINGS,AND 10 FT CLEARANCE FROM AAA B B.2 C C2 D D. F F.` �7'1 MECHANICAL INTAKES. 2 ROUTE EXHAUST DUCTS UP TO ROOF WITH 4"DIAMETER CVO ate' DUCT. CAP AT ROOF WITH BROAN MODEL 634 OR EQUAL. 3 GENERAL KITCHEN EXHAUST TO RUN CONTINUOUSLY.USE Sarvcyia9• FAN TYPE EF-1 SET AT 40 CFM. 4 PROVIDE 24 HR TIMER FOR EXHAUST FAN TO BE USED FOR 702 JEFFERSON ST WHOLE HOUSE VENTILATION.TIMER SHALL HAVE MANUAL VANCOUVER,WA 98604 PHONE: 360-852-8746 AND AUTOMATIC CONTROLS. PROVIDE LABEL THAT READS: FAX 360-852-8514 "WHOLE HOUSE VENTILATION(SEE OPERATING E-MAIL: info@jackola.com INSTRUCTIONS)." SEE TABLE ON M8.00 FOR RUNTIMES. WEB PAGE:www jackola.com 5 BEDROOM SHALL BE HEATED WITH ELECTRIC UNIT HEATER PROVIDED BY ELECTRICAL CONTRACTOR. REFER TO MECHANICAL SCHEDULES FOR EXACT MAKE,MODEL,AND SIZE. 6 ROUTE REFRIGERANT LINES DOWN TO HEAT PUMPS LOCATED IN PARKING AREA ON LEVEL 1. REFERTO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR PIPE SIZING. O7 BOTH FAN COILS IN THE 3 BEDROOM APARTMENTS WILL BE 1 CONNECTED TO A SINGLE HEAT PUMP. EF-1 EUH-1 O n II ® FC-2 6 7 I EUH-1 5 11 : ...__ EF-1 - 2 EF-1 == _ D3 FC-2 6 7 11 [rMff � L I CI- - -M. 4.0 I 4. - .II FC-1 6UNIT2.3 FC-1 63 4RG156'x6°/__ - � UNIT 3.2 4� I - _.--. 3 6 7 1 - gy UNIT 3.1 6D3 EF-1 I 5 J ® O SD1 75 _ ) n 5 � 173) 6 2x12 EF-1 EUH-1 { I I I FC-1 6 EUH-1 5 l O j Q M I I I UNIT 17 SIM �I - 5 ppRg 6 !,r r— ..x6., EUH-1 Q 4 � _ FC-1 II I�i_� �,� EF-1 �__ w I UNIT 2.3 SIM. .. - UNIT 2.1 TYPE A SIM IIvy� 4"� Q 11- 1 - - - 616 RG 75 602 a 1 6'x6'/- EUH-1 U Q LAUNDRY 605 4-0 �7 L S 0 FC 1 6 GS - 4.0 I I 5 EUH-1 0 EUH-1 5 5 EUH- EUH-1 5 EFEF-1 6 FC-1 C FC-1 '" O EUH-1 Rd 150 4" II 4 II 4., 5 - ! 8.><8" - 8'x6'/- �; I UNIT2151M. UNIT 2.151M. EF1EFII 611 EF-1MEMARM I '---- - - ,CT _ " x _ 5_ l5 615 - o 4.0 61212SDl 150 6' 12x12 II 4"0 II 6"x6• -- — - - w —r 6"x6" _ 24"x10" —28'x10' _ _ IT 6 --- - -� - - - c 4'0 - � � �i c - 4'0 4"0 6 SHEET 40 (� _ _ _ �O v O O O EF-1 EF-1 (I 3 II II �P'0 I II II II LEVEL 6D HVAC _ 6.A PLAN�p 6.A II4,0 u II 4„0 UNIT2.151M. II 4.0 4"0 I UNIT 2.I SIM. PLAN EF 1 �I �LA- 4"0 ILL ® II O O 11 C� (\1> 7F 4"0 O 4"0 --. ,, -O 4"0 I I 1 O O O II II DRAWN: MRC UNIT 1.1 UNIT ILA UNIT 1.1 UNIT 1.1 UNIT 1.1 FC-1 6 614 - 613 EF-1 — 612 'I EF-1 610 EF-1 _ ® EF-1 __ O 1 O 4 O CHECKED: ARw 5 EUH-1 EUH-1 S DATE: 06/12/2020 6.E O EUH-1 EUH-1 5 7 _ _ -_ _- _- _ � = 989902 i 6 FC-1 6 FC-1 6 FC-1 6 FC-1 6 FC-1 REVISIONS" 0 EUH-2 OS EUH 2 5 EUI�2 5 EUH-2 S I EUH-2 5 ARCH COMMENTS 1/24/2020 BID SET REVISIONS 3/13/2020 MASON INDUSTRIES, INC LODE REVISIONS 11/24/2020 THIS DRAWING HAS BEEN REVIEWED FOR SEISMIC BRACING j�aED PROP OF THE FOLLOWING UTILITIES: �D,S GINEE.R B/0 ❑ SUSPENDED PIPING —14828 'r.. ❑ SUSPENDED DUCTWORK mac/ �7 ! THE wFORMAnON CONTAINED HEREIN B B.2 C C.2 D D.2 ! E n, OREGON IS PROPRIETARY. THIS DOCUMENT ❑ SUSPENDED ELECTRICAL TRAY/CONDUIT G MAY NOT BE USED OR REPRODUCED O WITHOUT THE WRITTEN CONSENT OF WE HAVE DETERMINED THAT NO SEISMIC BRACING IS �4 qR.27,it JACKOLA ENGR.BARCH.,P.C. REQUIRED FOR THE ABOVE SYSTEM(S) BASED ON THE ��OHAlk* REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON ifXPIRES: 12/3012022 INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). NO OTHER RESPONSIBILITIES IS TAKEN OR IMPLIED NWITH OTESHIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 060 6O LEVEL 6 HVAC PLAN PIPER 1 1/8a = V-00 0 4' 81 po /iI KEYNOTES 1 PROVIDE 36"x36"RELIEF VENT HOOD. BASIS OF DESIGN: GREENHECK FGR. -SINCE. •19fi9. -- _. 2 COMBINATION FIRE/SMOKE DAMPER TO OPEN ON A A.1 DETECTION OF SMOKE. PROVIDE WITH MANUAL OVERRIDE. � m c KJyc n Aran.Surveylog d 702 JEFFERSON ST VANCOUVER,WA 98606 PHONE: 360-852-8746 FAX: 360-852-8514 EMAIL: infoCjackola.w WEB PAGE:w jackola.com II HP-1 HP-1 HP-1 HP-1 4 HP-2 HP-1 HP-1 HP-1 HP-1 i HP-2 HP-2 HP-2 0® HP-2 HP-2 I u~ l`9IJ HP-1 HP-1 � O OO HP-1 I, HP-1 � Q HP-1 HP-1 - Q DO HP-1 �� - -- --. . - 7)7 '._ -. Pi � SO 4 H HP-1 HP-1 - ! TJERNLUND MODEL RT1500 VJ 120V-V2 HP Q EF-3 EF-5 EF-5 !V^VVI VL i, HP-1 HP-1 HP-1 HP-1 HP-1 � `1 GREENHECK MODEL G-123VG 120V-1/2 HP -- _- COMBINATION FIRE/SMOKE O2 DAMPER ' 777 HP-1 HP-1 GREENHECK MODEL ERCH-20 -- - - - - -- WIGHT=2800LBS -� O.O _ . _ _-. . VOLTS=208/3 O® -.. _ _ ®® SHEET .- MCA=34.7 --- 6EF-2 MOCP=50 HOOFPLAN Ann EF-2 HP-1 HR3 n GREENHECK MODEL G-123VG GREENHECK MODEL G-123VG Ir IS IIV 120V-1/2 HP 120V-1/2 HP HP-1 HP-1 HP-1 HP-1 DRAWN: MRC HP-1 HP-1 HP-1 HP-1 H HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 ® o CHECKED: ARW e s ® DATE: 06/12/2020 6.iB JOB#: 191102 REVISIONS: HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 HP-1 ARCH COMMENTS 1/24/2020 Roof Equip Move 12/08/2020 MASON INDUSTRIES, INC THIS DRAWING HAS BEEN REVIEWED FOR SEISMIC BRACING X00 PROP'.. OF THE FOLLOWING UTILITIES: O� aGINE�c ❑ SUSPENDED PIPING !, ❑ SUSPENDED DUCTWORK THE INFORMATION CONTAINED HEREIN OREGON 6 PROPRIETARY. THIS DOCUMENT C.2 D ? lz ❑ SUSPENDED ELECTRICAL TRAY/CONDUITMy 99p MAY NOT T THE SED ORWRTEREPRODUCED WITCONSENT OF OH WE HAVE DETERMINED THAT NO SEISMIC BRACING IS X40 R'2A JACKOLA ENGR.&ARCH.,P.C. � RMP REQUIRED FOR THE ABOVE SYSTEM(S) BASED ON THE REQUIREMENTS OF ASCE 7 CHAPTER 13 AND MASON EXPIRES' 1730/2022 INDUSTRIES SEISMIC RESTRAINT GUIDELINES (OPA-0349). NO OTHER RESPONSIBILITIES IS TAKEN OR IMPLIED WITH THIS CERTIFICATION BY MASON INDUSTRIES, INC. BY: NN DATE: 3/16/21 n /� /,-� ❑ O O NOTES: ROOF MECHANICAL PLAN PIPER 0 4' 8' 16' C MASON INDUSTRIES, Inc. Alanurncturers of Vior000n Control Products NY M0 Ra ro Drive ro B21SmltCentA NY 117#7 SEISMIC BRACING SUMMARY FOR SUSPENDED PIPING 350 Rabro Drive 2101 W Crescent Ave.Suite O Hauppauge NY 11788 Anaheim.CA 92801 6311348-0282 71415352727 FAX 6311348-0279 FAX 7141535-5738 Info Mason-Intl.corn InfolZbMasonAnahemi.com PROJECT:TIGARD TRIANGLE Reference :ASCE 7 a5 8 10 30 4' 13.1 10 SSBS72 HB- N TBD 1 1/2X 2-3/4' C7/C8 8 C9 1. :1 H7 er HBAM71 d4 Ole&: Design Code ( ) s 618 a ( ) 5 SB 29 182 1.This drawinghas been modified from its original version b Mason Industries to include seismic bracinglocations,bracingcomponents,seismic and gr ' loadin Information CUSTOMER:MASON OREGON MAX.SEISMIC-9-FORCE= 0.22 (ASD) Fp=0.4•Ap•Sds•Ip•(1i2'7A,yRp•0.7 31 4' 13.1 20 SSBS-12 SHB-518 Na TBD (1)12•X 2-314' C7/C8 7.5:1 H7 or HaA/H71 5/8 BB 59 232 g yg g 32 4' 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)1rz•x 2-3/4• c71C8 1.5:1 H1 or H8AM11 sre Be Sg 232 for the suspended piping system shown. The Professional Engineers'seals appear on this document assume responsibility for the validity of only the seismic bracing elements, MASON EON-.34896 AP=212 RP=3 Fp shall not be greater Nan 1.65ds'Ipro.7 33 4• 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12•X 2-3/4• C7/C8 1.5:1 H7 or HSAM71 518 BB 59 232 point load data and not for any Architectural,Civil,Mechanical,Electrical or any other engineering or design aspect of the work. DATE:3/162021 IP=1.00 z=1 and less Na 0.3-Sds-IWO.7 34 4' 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12'X 2-314' C7/C8 1.5:1 H7 or HBAM71 ser ea 59 232 2.Construction shall not In until all ovals are in ace,including approval of this submittal b owner's agents,consultants,and/or b building permit an check. Mason •SINCE. .1969• OWN: NN GR Sits=0.720 h=6 Fpr=0.2•Sds•0.7 35 4• 13.1 20 SSBS-12 SHB-5'8 Na TBD (1)12•%2-314' C7/C8 7.5:1 H1 or H8AM71 5/8 88 59 232 approvals PI gaPP Y g y 9pe plan DWG.NO.:P7.10 STRUCTURE: Minimum 3000 PSI NartW Weight concrete 36 4' 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12'X 2-3/4' C7/08 1.5:1 Ht or HaAM11 518 98 59 232 Industries, Inc.will not assume any responsibility for construction done prior to the aforementioned approvals. F.C- 37 4• 13.1 2D SSBS-12 SHB-5/8 Na TBD (1)12'X 2-3/4' C7/C8 1.5:1 H7 or H8A/HI1 5/8 88 59 232 Seismic Component Sdsmic Rea/Aon Loads b Slmdure 39 4' 13.1 20 SSBS-12 SHB-5/8 Na Teo (1)12'X 2-3/4• EWES 1.5:1 H1 or HaAM11 5/8 88 59 232 SYMBOL LEGEND- I I I SYMBOL LEGEND- _�/ I I I t-/ . �' O� Tributary Brae 39 4' 13.1 b SSSS-12 SHB-5/8 Na TOD (1)12'X 2-3/4' C7/CB 1.5:7 H7 or HBAM77 5/8 176 117 320 II\ACLI-IfI-IIFTII L^, II/Q I�1LL_L_L1L/I I Q i C' Max.Utility Mason SAS Anchor Seismic Bracing Ma>amum Minimum Total Tension SOLID BRACING CABLE BRACING �- a.'^ Size Weight ht Seismic Connection 40 6' 13.1 20 SSBS-12 SHB-3/4 Na TBD 1 12'%2-3/a' C7/C8 1.57 H1 or H8AM11 3/4 88 59 232 ID# eIg Braced (Boit Dia.X Nom. Decals Brace M9k DMaBs Harper Logit an Support 41 6' 13.1 40 SSBS72 SHB 314 Na TBO (1)12'%2-3/4' C7/C8 1.5:1 Ht or H8AM71 3/4 176 117 320 6PED PROFF Og Jsc (Ibsm) Embedment) (Re/.PS-1) Ratio 5¢e Rad(01s) q 3 4 J Distance(11) Upper Bracket Lower Bracket SLDB CCB (Ref.PS7) Tension 0ba) Shear(tis) 42 6' 73.1 20 5585-12 SHB-3/1 Na TBD (1)12'X2-3/4' C7/CB 1.5:1 H1nH8AM11 3l4 88 59 232 u.q,.rm,y arere uo:emwel eama dYy aGINEF �i0 ife �9 V� 43 6' 13.1 20 SSBS-12 SHB-3/4 Na TBD (1)12'X 2-3/4' C7/CB 1.5:1 H1 or H8AM71 3/4 88 59 232 lar Tr H.e.. T.wz.H.ww. (4 q ' re,SurvrP db S' 13.1 20 SSBS-12 SHB-3/4 Na TBD 1 1rz•X 2-3/4' C7/C8 1.5:1 H7 or H8AM71 3/4 88 59 232 1 1.25' 3.8 40 SSSS-12 SHB-3/8 n/a TBD (1)7rz'X 2-3/4' C7/C8 1.5:7 H7 or H8AIH71 3/8 51 34 93 45 6' 13.1 20 SSSS-12 SHB-3/4 Na TBD (1)12'X 2311' C7/C8 1.5:1 H7 or H8AM71 3/4 88 59 232 14823// 702 JEFFERSON ST 2 125• 3.8 40 SSBS-12 SHB-318 Na TBD (1)12•X2-3/4' C7/C8 1.5:7 Ht or HBA/H71 318 51 34 93 46 6' 13.1 20 SSBS-12 SHB-3/4 Na TBD (1)12'X23/4' C7/C8 1.59 H1 or H8AM71 3/4 88 59 232 I`^"/yI'\ IIS ILII I' SII 1� `�- � - L VANCOUVER,WA 98604 3 125' 3.8 40 SSBS-12 SHB-3/8 Na TBD (1)12'X2-314• C7/C8 1.5:1 H1 ofH&WI1 3/8 51 34 93 47 6• 13.1 40 SSBS-12 SHB3/4 Na TBD (1)12'X2-3/4' C7/C8 1.5:1 H1 mH8AM71 3/4 176 117 320 T I I I Q OREGON 7 PHONE: 360.852.8746 4 1.25' 3.8 40 SSSS-12 SMB-3/8 Na TBD (7)12'X 2-3/4' C7/C8 1.5:1 H1 or H8A/H11 3/8 57 34 93 48 6' 13.1 20 SSBS-12 SHB-3/4 Na TBD (1)12•X 2-34' C7/C8 1.5:1 H1 or H8AM11 3/4 as 59 232 ^ro:crou"i a ere T. 1- T.Bi.I* G FAX: 360-952-9514 5 125' 3.8 40 SSBS-12 SHB-3/8 Na TBD (1)1rz•X 2-3/4• C7/C8 1.51 H1 or HSA1H11 3/8 51 34 93 49 6• 13.1 40 SSBS-12 SHB-3/4 Na TBD (1)12•X2-3/4' C7/C8 1.5:1 H1 or H8AM71 3/4 176 117 320 b�8was" Tr H.y.. H""•e r�"""A"� �r� �'/lf,r,1 E-MAIL: infoijackola.carn 6 125' 3.8 40 SSBS-12 SHB-3/8 Na TBD (1)12'X 2-3/4' C7/C8 1.5:1 H7 a H8AM71 318 51 3/ 83 50 6' 13.1 20 S58S-12 SHB-3/4 Na TBD (1)12'X 2-34' C7/C8 1.5:1 H7 or H8AM11 3/4 88 59 232 I '40j P,� WEB PAGE:www.jackala.com 7 7.25' 3.8 40 SSBS-12 SHB-3/8 Na TBD (1)12'X 2-3/4' C7/C8 1.51 H7 or HBAM71 3/8 51 34 93 51 8' 13.1 ZO SSBS-12 SHB-3/4 Na TBD (1)12'X 2-3/4' C7/C8 1.5:1 Hl or H8AM71 3/4 88 59 232 r�I I I I I�I�I OHAfLMI 8 1.25' 3.8 40 SSBS-12 SHB-3/8 n/a TBD (1)12'X 2-3/4' C7/CB 1.5:1 H7 or MBAM17 3/8 51 39 93 52 8' 13.1 20 SSSS-12 SH&3/4 Na TBD (1)12'%2-3/4' C7/C8 1.5:1 H7 or HBNH11 3/4 88 59 232 9 1.25• 3.8 40 SSBS-12 SHB-3/8 Na TBD (1)12'X2-3/4' C7/Ca 1.5:1 H1 err HSAM 11 3/8 51 34 93 EXPIRE$: 12/30t2D72 10 1.25' 3.8 40 SSSS-12 SHB-3/8 Na I TBD (1)12•X 2-3/4• C7/C8 1.5:1 Ht of HaMi11 3/8 51 34 93r, n e,aca t w naa ww e,o w r.T0 eau I. 11 1.25' 3.8 40 SSBS-12 SHB-3/8 We TBD (1)12'X 2-3/4' C7fC8&C9 1.5:1 Ht of HSA/H11 318 51 34 93 T y n'g" r'y"e 8"g". 12 125• 3.8 40 SSBS-12 SHB-3/8 Na TBD (1)12•X 23/4• C7/C8 1.5:1 H7 or H8AM11 3/8 1 51 34 93 PROFLCS 13 4- 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12'X2-3/a' C7f-8 1.5:1 H1crH8NH11 518 88 59 232 �Y�V�-NGINEFR S',b 14 4' 1 13.1 20 SSSS-12 SHB-5/8 Na TBD (1)12'X2-3/4' C7/C8 1.5:7 H1 or H8AIH11 5/8 88 59 232 (V 15 4• 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12•X2-3/d' C7/C8 1.5:1 H1 or H8AIH71 5/8 88 59 232 l 16 4• 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12'X2-3/4' C7/C8 1.5:1 H1 or HIIAM71 518 88 59 232 17 4' 13.7 20 SSBS-12 SHB-5/8 Na TBD (1)12'X2-3/4' C7/C8 1.51 H1 or H8AMt1 5/8 88 59 232 18 4' 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12•X2-314' C7/C8 1.51 1-11 or HaAM11 5/8 88 59 232 HYD-1 8"RWL TO PLANTER 19 4' 13.1 20 SSBS12 SHB-5/8 Na TBD (1)12•X 2-3/4' C7/Ca 1.51 H1 or Hli"l1 5/8 88 59 232 2 OREGON F 20 4• 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12•X2-3/4' C7/C8 1.5:1 Ht or Ha"11 5/a a8 59 232 0PLANTER t 12 2SF) ,p 4/,fY 21 d• 13.1 20 SSBS-12 SHB-5/8 Na TBD (1)12'X 2-&4' C7/C8 8 C9 1.51 H7 or HaA Hl1 5/8 a8 59 232 5905 SF �1' 14' 2 Off' 22 4' 13.1 20 SSBS12 SHB-5/8 Na TBD (1)12'X2-3/4' C7/CB 1.5:1 H1 or Ha"11 5re a8 59 232 1 , - - ,I, GAS METER RA yMONO 23 4• 13.1 10 SSBS-12 SHB-5/8 Na TBD (1)12'X 23/4' C7/C8 8 C9 1.51 Ht or HaA0111 5/8 44 29 188 r0 50 37 52 T 2 PSI SERVICE 24 4• 13.1 10 SSSS-12 SHB-5/8 Na TBD (1)12•%2-3/4' C7/C88 C9 1.5:1 H7«HSAM11 518 44 29 188 O I� (D 0'F AT 850 MBH EXPIRES: 613(11=0 25 4' 13.1 to SSBS-12 SHB-5/8 Na TBD (1)12'X 2-3/4• C7/C8 8 C9 1.5:7 H7 or HaAA111 5re 44 29 188 f 350 FT DEV.LENGTH 26 4' 13.1 10 SSBS12 SHB-5/8 Na TBD (1)12'X 2-3/4' C7/C8&C9 1.5:1 H7 or H8AA711 5/8 44 29 188 4"W UP I I- 27 d' 13.1 10 SSBS-12 SHB-5/8 Na TBD (1)12•X 2-3/4• C7/C8&C9 1.5:1 H7 orHaAHI I Wit 44 29 188 I I 1 28 4- 13.1 10 SSBS-12 SHB-518 Ne TBD (1)7/2•X 2-314• C7/C8&C9 1.5:7 H1 or H8AIH11 5/8 44 29 188 29 4• 13.1 10 SSBS-12 SHB-5/8 Na TBD (1)12'X2-3/4' C7/C8&C9 1.5:1 H1 or HaA/H71 518 44 29 188 .. ._ . ._ ____ . _..__._ �_ ... .--.._-.- -_.___-- ._. ... ......... _._ .. -- -40 22 ! ELECTRICAL .__ � I I I I 117 I _ I of t 2"w UP 11/4"NG-1 18 D I I 51 i r1 Ioc 3p I 39 4"RWL UP "WUP 32 36 �LUP (2837• 48 21 _ - - _ - - - 3/4„CW(1) 4"RWL U v 4' R A(2825 SF) IL, 4"W UP (30205F) � _ 34 38 I 1 • I "RWLO UP - - - - - 4"RW 1/8"/1'-0" O 31 33 35 I 1A f Q O 'a p (D Q oo 00 15 z"w UP 14 D DN 4"W DN t 11/4"NG 16 wup V 4 I 19 i M. !TF,� I.1 Q WL o 0 4 a"RWL UP 1/R„/1,_0„ I - 43 el (357vml 0 - - - - - - 6- R _ I , F� 1 HP 2"FD-1 413/4"CW 3/4"CW + HYD-1 ~ 2"W UP 40 O I t;42 I c 4"RWL UP O nn (2708 SF) TRASH VO ( I 114 I 13 D 4'RWL UP I I 4"W UP 2 (306805) - - 46 ---------_ ------------------------ ------------------------------------ --- ----------------------------------- 8 - --- - - a o `-' 45 UP TO F 11 UP TO FD MAINTENANCE - WH-1 12 31 - BIKE ROOM 1 O 108 O RR UPPER LOBB 9 O z -- TYP.4 i��Fr T_ -�2' V UP 116 O 107 106 SP-1 ^1I -1 UP TO FDL UP TO WC UPTOLAVUPTOLA UPTOWC-O 4"WUPO ® 2"CW "VUP UPTOFD " UP TO KS 2"WUP 4"WUP HYD-1 - 3/4"CW �3„WUP I 3' W DN 4"W DN 8 8 e 2"V UP RPBP-1 1 1/2"CW 1"CW 1 BT 1 1 '10 _ 1/8"/1-0" 3 RWL UP SHEET LEVEL p q 6 1 d -O ! 0 0 2"W UP � - - - - - - - - 1005F IS LS V�L� Il p II np p V (gip t KS-1 1 1/2"VUP 2' WUP 1'1/2"VUP 2"VUP 1 1/2"V P-) I 2"VUP .. 3/41 CW 2" \P r c...c . O 2•W UP I�ISIUJ IIVI1 0 BV 1 2"WUP ,.� .. 0(-3 � 2"W UP yVG1 1 WUP 2"W U � I iAR AR. PUN�l�pp LAV- 1 4"WUP 6Fl �u1 „ I �� o �� v� - - ----__ 3"50SF) C PLSWOV t 2"VU �� ( II i � (350 SF) 1 O 1 4 W UP 6FL 6FL 4"WUP a 1 r b. 4„W U 1 7 4"WUP 29 = I UNIT 2.1A I UNIT 2.1B i112 O i 111 , Q 27 1 OFFICE OFFICE 4"W UP 4"WUP DRAWN: �m4P0®P 1 1 I a 24 1 UNIT2.1B 104 103 LOBBY -- 23 D c i C-- 25 26 uo OFFICE leo CHECKED: 6h®Ck®P loz 1 DATE: 06/1Z12020 1 6.B 1 1 _ _ - JOB#: 101102 7 REVISIONS: CODE REVISIONS 11/24/2020 THE INFORMATION CONTAINED HEREN -- IS PROPRIETARY. THIS DOCUMENT F F.1 GGA r MAY NOT BE USED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF -- - JACKOLA ENGR.&ARCH.,P.C. 00 look pal o 10 LEVEL 1 PLUMBING PLAN 0 4' 8' 16' M E C H A N i