Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (51)
M EC2020-00662 �I HVAC SYMBOL LEGEND MECHANICAL GENERAL ABBREVIATIONS HVAC GENERAL NOTES ` U) Rg DESCRIPTION SYMBOL DESCRIPTION SYMBOL ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME Z rn _- _ _ 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRALTO IS O COO _ m RI BARE RECTANGULAR SHEETMETAL 14X12 SA FLEX DUCT S rT11L,g11 AC AIR CONDITIONING UNIT FCU FAN COIL UNIT NOM NOMINAL R T COORDINATE WITH O N ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. AFF ABOVE FINISHED FLOOR FD FIRE DAMPER NTS NOT TO SCALE � F_ E I - - -- AHU AIR HANDLING UNIT FLA FULL LOAD AMPS OBD OPPOSED BLADE DAMPER 2. MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2019 OREGON MECHANICAL SPECIALTY CODE(GMSC),2019 OREGON STRUCTURAL 1 cm O T SOUNDLINE SHEETMETAL(GENERAL NOTES) 14x12 SA-SL_- EQUIPMENT FLEX ROUND CONNECTOR _240 >t ---------- - AL ALUMINUM FOB FLAT ON BOTTOM OD OUTSIDE DIMENSION SPECIALTY CODE(OSSC),2017 OREGON PLUMBING SPECIAL CODE(OPSC)AND 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE(CH.13 OF THE 2019 OSSC). 'Q J m y ik 'f"' "-N SHEETMETAL W/INSULATION(GENERAL NOTES) 14x12 SA-W EQUIPMENT FLEX RECTANGULAR CONNECTOR 24x24 BAS BUILDING AUTOMATION SYSTEM FOT FLAT ON TOP POC POINT OF CONNECTION O a LL E U ..........T,."+. BDD BACK DRAFT DAMPER FSD FIRE SMOKE DAMPER PRV PRESSURE REDUCING VALVE 3. FABRICATE AND INSTALL ALL DUCTWORK IN ACCORDANCE WITH CHAPTER 6 OF THE GMSC AND WITH CURRENT SMACNA STANDARDS.EARTHQUAKE BRACE ALL DUCTS cu CO U U BI BLACK IRON GALV GALVANIZED PVC POLYVINYL CHLORIDE 28"DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12"BELOW STRUCTURAL SYSTEM. �r /r 9 SUPPLY DUCT UP/DOWN 1',i. Sim 6 12020 $ BARE ROUND SHEETMETAL 120 SA _ BOD BOTTOM OF DUCT GC GENERAL CONTRACTOR REO'D REQUIRED O >- r o E O �I ROUND SHEETMETAL W/INSULATION GENERAL` "- 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 'Z _ LL ( 12o SA-W EXHAUST DUCT UP/DOWN j j-)•`} BOTT BOTTOM GENX GENERATOR EXHAUST RPBA REDUCED PRESSURE BACKFLOW ASSY �. O ^�� !l T t�C..-, NOES) ---- �- - BTU BRITISH THERMAL UNITS GLVNL GALVANNEAL RTU ROOFTOP UNIT 0 - aN J ' r VF I1(3A I..J aI ---- -- ;--, 5. SEAL FULL EXTENT OF NEW DUCT SYSTEM JOINTS,SEAMS AND WALL PENETRATIONS. J BARE OVAL SHEETMETAL 14x120 SA RETURN DUCT UPIDOWN ,I I 1(• ,; BTUH BRITISH THERMAL UNITS PER HOUR GPM GALLONS PER MINUTE SA SUPPLY AIR V - UJ rn D_ LDI i V G DIM iJ(Ci 1 S -- CAT1 CATEGORY ONE VENT GREASE GREASE DUCT SO SMOKE DAMPER 6. INSULATE NEW DUCTWORK AS INDICATED ON PLANS;IN ACCORDANCE WITH 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE. V ? y U OVAL SHEETMETAL W/INSULATION(GENERAL NOTES) 14X120$A-W SUPPLY AIR TERMINAL RECTANGULAR AND SQUARE ® CAT4 CATEGORY FOUR VENT GWB GYPSUM WALL BOARD SL SOUND LINED ® -INSTALL DUCT WRAP WHERE INDICATED;1"THICKNESS,0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM.FOIL VAPOR BARRIER. CFM CUBIC FEET PER MINUTE HP HORSE POWER HEAT PUMP SM SHEET METAL c� LL a g EXAMPLE OF EXISTING 14x12 SA RETURN AIR TERMINAL RECTANGULAR AND SQUARE CPVC CPVC MATERIAL HVAC HEATING,VENTILATION AND AIR COND. SP STATIC PRESSURE -SUPPLY DUCT WHICH CONVEYS SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F WHEN LOCATED IN CONDITIONED SPACE SHALL BE DS DUCTBOARD HX HEAT EXCHANGER SS STAINLESS STEEL LAT LEAVING AIR TEMPERATURE T THERMOSTAT DEMO DEMOLISH L INSULATED WITH A MINIMUM OF R-3.3,WHEN LOCATED IN UNCONDITIONED SPACE R-0,WHEN LOCATED IN INDIRECTLY CONDITIONED SPACE R-1.9,AND WHEN LOCATED EXAMPLE OF DEMO X.Y%%XX%X_X_-pp�laRw EXHAUST AIR TERMINAL RECTANGULAR AND SQUARE ® ® DDC DIRECT DIGITAL CONTROLS INSIDE DIMENSION SUSP SUSPENDED OUTSIDE THE BUILDING R-8(CLIMATE ZONE 4)OR R-12(CLIMATE ZONE 5). EXAMPLE OF NEW 1412 SA RADIAL AIR TERMINAL ®O DIFF DIFFUSER LBS POUNDS TOD TOP OF DUCT 7. FLEXIBLE DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER,1 1/2"FIBERGLASS INSULATION,AND NON-PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT DMPR DAMPER LWT LEAVING WATER TEMPERATURE TV TURNING VANES SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEXIBLE DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED VIN LENGTH UNLESS NOTED EXAMPLE OF FUTURE(N.I.C.) 14X12 SA SUPPLY AIR SLOT DIFFUSER DN DOWN MAT MIXED AIR TEMPERATURE TYP TYPICAL OTHERWISE. E EXISTING MBH ONE THOUSAND BTUH UNO UNLESS NOTED OTHERWISE 0 '/O N EXPOSED QUALITY SHEETMETAL 14X12 SA-Q RETURN AIR SLOT DIFFUSER EAT ENTERING AIR TEMPERATURE MCA MINIMUM CIRCUIT AMPACITY VAV VARIABLE AIR VOLUME 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2019 OSSC. b EC EGGCRATE MD MOTORIZED DAMPER VD VOLUME DAMPER 9. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. CLEANROOM QUALITY DUCTWORK 14X12 SA-C EXHAUST AIR SLOT DIFFUSER EER ENERGY EFFICIENCY RATIO MIN MINIMUM VFD VARIABLE FREQUENCY DRIVE n Z _W o EF EXHAUST FAN M-M MACDONALD-MILLER W DUCT INSULATION WRAP DUCTBOARD(1"FIBERGLASS) 14X12 SA-DB POINT OF CONNECTION ELEV ELEVATION NC NORMALLY CLOSED W/ WITH 10 HVAC EQUIPMENT,PANELSHALL BE PROVIDED CALESAND D INSTALLED BYPERS B ELOCATED I EASILY ACTOR.ACCESSIBLE LOCATIONS. S DOOR UNLESS SIZE FOR VALVES AND DAMPERS ARCHITECTURAL DRAWINGS,REQUIRED ACCESS ESP EXTERNAL STATIC PRESSURE NIC NOT IN CONTRACT WELD WELDED w CONTINUATIION OF ROUND DUCT CENTER LINE EWT ENTERING WATER TEMPERATURE NO NORMALLY OPEN 0 VOLTAGE PHASE 8 DUCT DIAMETER CONTINUATION OF RECTANGULAR DUCT THERMOSTAT A 11, MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. --\� QT AIR FLOW IN SYMBOL CARBON MONOXIDE SENSOR ® 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE,RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER.RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT,GENERAL CONFIGURATION OF DUCT AND PIPE AIR FLOW OUT SYMBOL NITROGEN DIOXIDE SENSOR ®D HVAC SYSTEM ABBREVIATIONS DISTRIBUTION SYSTEM, INCLUDING SIZES,AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE:SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE MECHANICAL EQUIPMENT TAG F_A_HU_0_01j OTHERSENSOR ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME SERVICE AGENCY,HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. C COMB-GALV COMBUSTION AIR EA AL - EXHAUST ALUMINUM OA OUTSIDEAIR KEYED NOTE O ELECTRICAL SWITCH $ SA SUPPLY AIR LP EA SS EXHAUST SS 304 OA-KOOL OUTSIDE AIR KOOLDUCT 14. DAMPERS USED FOR OUTDOOR AIR INTAKE,EXHAUST,OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT V W.G.(PER AMCA STANDARD 500D): d SA-KOOL SUPPLY AIR LP KOOLDUCT EA AL WELD EXHAUST ALUMINUM WELDED RLF RELIEF AIR MOTORIZED DAMPERS:4 CFIWS.F. GRAVITY DAMPERS:20CFWS.F.(40 CFM/S.F.FOR DAMPERS SMALLER THAN 24"IN EITHER DIMENSION). ACCESS DOORS MITERED ELBOW W IH TURNING VANES SA AL SUPPLY AIR LP ALUMINUM EA GALV WELD EXHAUST GALV WELDED RA RETURN AIR 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. ------------- SASS SUPPLY AIR LP SS 30428 EA GLVNL WELD EXHAUST GALVANNEAL WELDED DB DUCTBOARD RATED ENCLOSURE SA AL WELD SUPPLY AIR LP ALUMINUM WELDED EA SS WELD EXHAUST SS 304 WELDED FLU-CATs FLUE VENT-CATEGORY 1 SA GALV WELD SUPPLY AIR MP GALV WELDED EA BI GREASE EXHAUST GREASE BLACK IRON WELD FLU-CAT4 FLUE VENT-CATEGORY 4 SA GLVNL WELD SUPPLY AIR MP GALVANNEAL WELD EA GALV GREASE EXHAUST GREASE GALV WELDED FLU-CPUC FLUE VENT-CPVC MATERIAL NOTE: SIZE REFLECTS ACTUAL SHEET METAL DIMENSION AND DOES NOTACCOUNT FOR INSULATION OR LINING SAA SS WELD WELDED EXHAUST AIRY AIR LP SS 304 2B M AGALV GREASE MAKE UP/GRST EASE SS 304 WELDED FLU�SS FLUE VENT-SHOP BUILT FLU-GALV FLUE VENT-SHOP BUILT SS304 EXHAUST FAN SCHEDULE F UNIT FAN MOTOR Wi LI AIR TERMINAL / LOUVER SCHEDULE NO. AREA SERVED MFG&MODEL NO. TYPE CFM ESP RPM HP VOLTIPH FLA BDD LBS NOTES W MANUFACTURER& ROOM PRESSURIZATION & AIR FLOW MATRIX EF-10 HAZARDOUS COMPOUNDING GREENHECK USF UTILITY SET 600 1.5 2150 1/2 46013 -- - 150 1,2,3,4 TAG MODEL NUMBER CFM DP(IN.WG) THROAT SIZE OVERALL SIZE,WEIGHT(LBS) NOTES O J L-1 GREENHECKWIH 600 0.05 14X14 28X28 50 1,2 ¢ NOTES: V y, f LL 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. a 0 a U QOQ E a � 2. MOTOR STARTER BY ELECTRICAL CONTRACTOR. LU K y >_,- > O Q a a 3. UPSLAST CONFIGURATION WITH 10'TALL DISCHARGE STACK INTEGRAL TO FAN UNIT.RESTRAINED VIBRATION ISOLATORS SIZED FOR FAN AND STACK. O! NOTES: ROOM NAME/ Q O LL Z, a< ¢ C 2 f y Z r 4. WEATHERHOOD,SCROLL DRAIN,BOLTED ACCESS DOOR,PERATECTOR COATING,REDUNDANT BELT DRIVE,FAN BEARINGS L(10)80,000 HRS. z > w �� aH Ow >w j 1.ALUMINUM CONSTRUCTION,ACCESSORY INSULATED ROOF CURB. SPACE USE w O O t- U)O O n Q 9 O 2.INSECT SCREEN. _ w n g ~ y t _ X U = Q w N C7 OS ° DUCTWORK SCHEDULE STERILE COMPOUNDING 144 8.083 11701300 36 P 633 32 160 633 62-88 30-60 GARBING AREA 180 6.083 39 P 874 40 220 874 82-BB HAZARDOUS COMPOUNDING 112 9.083 1020 31 N 549 32 140 558 82-88 30-60 558 CLEAN ROOM AIR CONDITIONER SCHEDULE WORKING PRESSURE SMACNA PRESSURE SMACNA SEAL SERVICE I USAGE LOCATION MATERIAL NOTES O OSA REQUIREMENTS BASED ON GMSC (IN.WC) CLASS(IN.WC) CLASS J UNIT SUPPLY FAN EAT LAT AMBIENT TOT STENS HUMID REHEAT SEER/ ELECTRICAL WT V NO. MAKE/MODEL CFM ESP HP DB/WBDB/WB ' MBH ' MBH LBSIHR KW SERI IPLV' VOLT/PH FLA LBS NOTES ABBREVIATIONS: OUTDOOR AIR INTAKE BETWEEN AMBIENT AND FCU GALV.STEEL -1 -1 A 1 � FCU-1 DATA AIR DALA 0634 2270 1.5 2.0 75/82.5 53'52 66.1 55.1 13.3 10 480/3 27.2 950 1,2,3 N =NEGATIVE LOW PRESSURE SUPPLY AIR FROM FCU UNITS TO... GALV.STEEL +1 +1 A 1 CU-1 DATA AIR DRCU 1134 105 88.1 55.1 480/3 19 850 P =POSITIVE FLEXIBLE DUCT CONNECTION TO FFU PREINSUL.FLEX +0.5 +1 A 2.3 PP =POSITIVE RETURN AIR FROM CLEANROOM TO FCU I GALV.STEEL -1 -1 A 1 NOTES: EA EQUALRNOT LNEAUBTLRAL EXHAUST AIR EF-10 SYSTEM GALV.STEEL -1 -1 A 1,4 1. CONDENSER CAPACITY AT 105FAMBIENT 2. ACCESSORIES: NOTES: FILTERS-2"THICK MERV 8,INFRARED HUMIDIFIER,ELECTRIC REHEAT. 1. SHEET METAL GAUGES AND FITTINGS PER SMACNA AND MACDONALD-MILLER DUCT CONSTRUCTION STANDARDS. 3. WITH DUAL FLOAT CONENSATE PUMP AND STAINLESS STEEL CONDENSATE PAN. 2. THERMAFLEX"GKW OR EQUAL,WITH 5 FOOT MAXIMUM LENGTH.BENDS MIN.3X DIAMETER. TEST, ADJUST AND BALANCE 3. INSTALL PER MFG.GUIDELINES AND INSTRUCTIONS. 4. EF-10 SYSTEM GALVANIZED STEEL FULL EXTENTS FROM FAN VIBRATION ISOLATOR TO BIOLOGICAL SAFETY CABINET THIMBLE CONNECTION. VENTILATION SCHEDULE GENERAL: TO ACHIEVE DIFFUSERS AND GRICE LLE AIRF OWS SHOWN ON HE DRAWINGS.TE PERFORMANCE AS DESIGNED.ADJUST BALANCE DAMPERS AND FAN SYSTEM DESCRIPTON:CLEANROOM HVAC EQUIPMENT TO INCLUDE SPLIT SYSTEM AC UNIT AND REMOTE EXAUST FAN,EACH OF THREE CLEANROOM ZONES ESTABLISHES ELECTRIC DUCT HEATER SCHEDULE PRESSURE CASCADE FROM SPACE OMSC REQUIREMENTS SYSTEM FINAL PRESSURE CASCADE IS BY FFU SPEED MODULATION BYTO DIRTY.SUPPLY AND TCLREANROOM SUPPLIER UAL VIA EC MOTOR SPEED CE DAMPERS VCON ROLL TO PACE AIRFLOW OR RESSURE.SYSTEM IDE AGGREGATE ZONE AIRFLOW AND PRESSURE CASCADE. CONSTANT VOLUME RUNNING 24/7/385. UNIT ROOM ROOM NAME AREA OCC11000SF OCC CFWOCC CFMISF OSA RE(rD OSA EXHAUST DESIGN DT 001 STERILE COMPOUNDING 148 10 2 5 0.18 40 220 FCU-1:SUPPLY AND RETURN DUCT DAMPERS IN EACH OF THREE ZONES PROVIDE ZONE AIR BALANCE.REDUNDANT SUPPLY AND RETURN DUCT DAMPERS AT FCU PROVIDE NO- SYSTEM SERVED MFG&MODEL NO. KW VOLT/PH SIZE W"X H" MAX CFM MIN CFM STEPS "F CONTROL NOTES ADDITIONAL FCU AIRFLOW THROTTLING. EDH-01 STERILE COMPOUNDING NAILOR DHRR 2.0 48013 18"DIA 875 875 1 7 24V NEW,1,2,3 002 GARBING 185 10 2 5 0.18 30 180 EF-1: BRANCH DUCT DAMPERS PROVIDE AIR BALANCING TO BIOLOGICAL SAFETY CABINET AND SIDEWALL AIR INLETS.REDUNDANT DUCT DAMPER PROVIDES ADDITIONAL ED ±02 GARBING NAILOR DHRR N. 480/3 14"DIA 835 835 1 10 24V NEW,1,2,3 003 HAZARDOUS COMPOUNDING 115 10 1 5 0.18 30 140 560 EF AIRFLOW THROTTLING. EDH-03 I HAZARDOUS COMPOUNDING I NAILOR DHRR 2.0 480/3 14"DIA 550 550 1 11 24V NEW,1,2,3 NOTES: t OCCUPANT DENSITY AND SPECIFIC OSA BASED ON IMC TABLE 403.3.,OCCUPANT COUNT BASED ON ACTUAL USAGE NOTES: 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. OFFICE COPY 2 REQUIRED OSA BASED ON OMSC TABLE 403.3 DRAWING SHEET INDEX - MECHANICAL 2. FACTORY OPTIONS: -SLIP-IN TYPE NUMBER TITLE 24 VOLT CONTROL VOLTAGE CITY 007 TTGA "), -AIRFLOW PROVING SWITCH TMO.01 SCHEDULES _ _ -1"INSULATION REVIEWED P )" � j;;i5 COAULIANCE TM0.01S SITE PLAN _ _ -POWER FUSING-UL LISTED A roved: I FLOOR PLAN CONTROL SYSTEM DESCRIPTION DM2.01 LEVELI O LAN - -- 3. CONTROLLED BY ROOM THERMOSTAT,2-10V SCR. QTC; TM2.01 LEVEL I FLOOR PLAN _ I I TM2.02 ROOF PLAN _ A TM8.01 MECHANICAL DETAILS - �-xa.Q..,ca o a Permit #: o 00 6 GENERAL:FCU-1/CU-1 STAND ALONE CONTROLLER TO ACTUATE COOLING COIL AND REHEAT COIL TO MAINTAIN RETURN AIR TEMPERATURE AND HUMIDITY Address: j A j na AV SETPOINT.ROOM THERMOSTAT TO ACTUATE DUCT HEATING COILS TO MAINTAIN MINIMUM SPACE TEMPERATURE. S111IQ #: FAN FILTER UNIT AND UNIT CONTROL BY OTHERS. CONTACT LIST SCOPE OF WORK By' II Dam _ SEQUENCE OF OPERATION TITLE NAME COMPANY PHONE EMAIL GENERAL:INSTALL HVAC EQUIPMENT TO SUPPORT CLEAN ROOM INSTALLATION. 1JL DESIGN ENGINEER JEFF WELTER MACDONALD MILLER 503262-5410 ie0.watterfaknacmiller.mm 1. REVISE EXISTING RTU-9 DUCTWORK TO MAKE ROOM FOR NEW CLEANROOM HVAC SYSTEM. 6 ENGINEER OF RECORD GABRIEL HOY MACDONALD MILLER 503abb 280-9504 4ethwan Mmail1w mm 2. PROVIDE SPLIT SYSTEM AC UNIT.INSTALL FAN COIL UNIT IN CEILING SPACE,INSTALL CONDENSING UNIT ON ROOF. VALIDITY OF PER N IT DESCRIPTION: FCU-IICU-1 AND EF-10 OPERATES ON A 24/7/385 SCHEDULE. PROJECT MANAGER ANDY WARE MACDONALD MILLER 503262-5401 aadY.ware@macm1i1w mm 3. PROVIDE REFRIGERANT PIPING FROM CONDENSING UNIT TO FAN COIL UNIT. THE ISSUANCE OF A PERMIT FCU-1/CU-1 OPERATIONS MANAGER BRENT CAMPBELL MACDONALD MILLER 503380-5119 brentamobellComaaniller.mm 4. PROVIDE SUPPLY AND RETURN DUCTWORK FROM NEW FCU TO NEW CLEAN ROOM EQUIPMENT CONNECTIONS. BASED ON CONSTRUCTION STAND ALONE CONTROLLER MODULATES: 5. PROVIDE EXHAUST DUCTWORK FROM CLEAN ROOM CONNECTIONS TO FAN ON ROOF. DOCUMENTS AND OTHER SUPPLY FAN,TO RUN CONTINUOUSLY. 6. PROVIDE ALL ACCESSORIES REQUIRED FOR SPLIT SYSTEM AND EXHAUST FAN SYSTEM. DATA SHALL NOT PREVENT COOLING COIL,TO MAINTAIN RETURN AIR HUMIDITY AND TEMPERATURE SETPOINTS,50%RH(DJ)AND 84F(ADJ). 7. BALANCE SUPPLY,RETURN AND EXHAUST AIR SYSTEMS TO AIRFLOWS INDICATED ON PLANS. THE CODE OFFICIAL FROM HEATING COIL,TO MAINTAIN RETURN AIR TEMPERATURE SETPOINT 64F(DJ) & STARTUP AND TEST NEW EQUIPMENT TO VERIFY OPERATION IN ACCORDANCE WITH MANUFACTURER'S STARTUP INSTRUCTIONS, REQUIRING THE CORRECTION HUMIDIFIER,TO MAINTAIN 40%RH(DJ) OF ERRORS. OSSC 105.4 EDH-1.2.3 ROOM TEMPERATURE SENSORS MODULATE RESPECTIVE HEATER TO MAINTAIN ROOM TEMPERATURE SETPOINT 62F(DJ) O EF-10 OPERATES 24/7/365 BY DISCONNECT SWITCH. �0�/ G I"J_ FAN FILTER UNITS OPERATE 24/7/365,CONTROL SYSTEM BY OTHERS. z a FOR REFERENCE,MODULATE FFU SPEED TO MAINTAIN ROOM PRESSURE DIFFERENTIAL OR CONSTANT ROOM AIRFLOW OFFSET \ Q V/ AS SHOWN ON PLANS TO ACCOUNT FOR FILTER LOADING. CO) LIJ w N U-1 r J am J V 0 1NTERSTgTE 6 0Z p Q LL z Q rz LJLLJ � 9 mmm EXT#P90 EGO m o O U �u G a cf) yLO To ENGINEER: wsT REvlseD: s�F9Hmm ° J. WELTER 2020-09-25 CHECKED BY: pare ftG ED: G. HOY 2020-09-25 v II \ BIM: 138UEDATE: sw72NOAVENu A. STEPHENSON 2020-09-25 DRAWING NUMBER: 8120- 7013 SHEET NUMBER: PROJECT LOCATION T M 0 . 0 1 CITY OF TIGARD Approved b Planning C' Date: o S NORTH Initials: / - Z rnN AREA OF WORK—,, o`� � 79 no CU o } �o � o _jJ z (0 Q o LL < `r a H rc n 1 a Z � 'o W O Q KEYPLAN 5 0 FL z a H O D 7 G C.1 RELOCATE CEILING GRILL AND RECONNECTOUCT V (E)RTU-9 PHARMACY 1 x 1 1 L IN I CAP _ < J 1 F\ T I x Z W OM 130 Z J n 0 O O 0 LL Z 2 a W ( , 0� W wN v 0 B LL U Q zo Q 0 N JW 0 � ¢ W > CD o W (n T `O 00 J y ENGINEER LABT REVIBED: J. WELTER 2020-09-25 CHECKED BY: DATE PLOTTED: G. HOY 2020-09-25 BIM: 18 DATE: A. STEPHENSON 2020-09-25 DRAWING NUMBER: 8120-7013 BNEETNUMBER: DM2 . 01 s S E 1 VEL 11 DEMO PLAN - SHEETMETAL Z 0 2 4 B 18 F� L co oN QIco o" 1= of _� J aLL dat 2I Q cEi V 'I 3$ f0o O rEz eN U e 0 U =� w�j � (B ? °' O Q LL N� y ti I z ✓ r4i � � b lb w 3 2 s1 0 N W INT ATE 5 ERST T17 7 J V C Y s!i L T1TI � — G'O.o Illlp = � IIIIIIII ill mm — — — LLL I SW 72ND AVENUE i c G O W Z a aV N 7 N L O J Q m Q LL U � O -_j o Q C) ¢ w > D J ENGINEER I STREVISED. J. WELTER 2020-09-25 CHECI(ED BY: DATE PLOTTED: SITE PLAN G. HOY 2020-09-25 BIM: ISSUEUEDATE DATE: SCALE. 1"= 100-0 z A. STEPHENSON 2020-09-25 DRAWING NUMBER: 8120-7013 SHEET NUMBER'. TM0 . 01S F j L L7 �o _N Z o R AREA OF WORK — o" M OF m .. U� STERILE COMPOUNDING ROOM -0 J cLL `y m '---'� T FCU-1 T Qa =U H m u, Eco � po Ez ++ Q J Q� SJ 0 L� 5MU Z c o \! + L LL �4a j LEGEND: U GARBING ROOM O TEMPERATURE SENSOR p ' © MAGNEHELIC GAUGE(BY OTHERS) Q HUMIDITYSENSOR i 0 + (1 + O REFERENCE ¢ n + POSITIVE PRESSURE LEVEL 1 O ++ POSITIVE PRESSOR LEVEL 2 - - NEGATIVE PRESSURE w KEYPLAN HAZARDOUSCOMPOUNDING ROOM O ZONING PLAN SCALE: 1/4" = 1'-0" a 120 OA y UP W D D a0BALANCE OSA TO 560 CFM � N J U 140 RA 200 RA C BALANCE TO 145 CFM (TYP.6) FCU-i STERILE COMPOUNDING 160 SA 200 SA - - ROOM BALANCE STERILE COMPOUNDING TO 870 CFM Q N a m° m ro m m BALANCE STERILE v �c O 72 x 30 PLENUM AT FCU-1 C GARBING TO 630 CFM j RS/RL UP TO CU-1 `-- -------------------1} PROVIDE SEISMIC BRACING E RTU-9 I m 14m RA T m REDUNDANT BALANCE IN ACCORDANCE WITH OSCC DAMPER T ai 148 RA BALANCE TO 160 CFM a ACCESS 3/4"CONDENSATE DRAIN, (TVP.41 Q aa ROUTE TO SINK 10'0 SA Nm ao m m 140 SA a N y BALANCE DAMPER mm � I EDH-02 OUTBOARD OF CLEAN -I 140 RA ROOM FOOTPRINT,(TYP.5) GARBING ROOM § ____ _______ BALANCE TO 140 CFM `O fO MAINTAIN MANUFACTURER'S REQUIRED (TYP.4) INLET CONDITIONS 140 SA HAZARDOUS COMPOUNDING ROOM N tan N N m m m m m GALVANIZED STEEL BALANCE DAMPER ELBOW DOWN,THEN OUTBOARD OF CLEAN ROOM _ FLEXIBLE DUCT TO NFU FOOTPRINT(TYP.3)BALANCE TO 500 CFM INLET CONNECTION. �.,.( 120 EA (TYP. 14) BALANCE TO 30 CFM(TYP.2) 60 EA 120 EA UP BALANCE DAMPER IN RISER NEAR CEILING FOR ACCESSIBILITY G Q O n z Z O w /may Q N O N L� U U a � O LL z Q w J � g L1J > O W U) r° a J i U) ENGINEER: LASTREVISED'. J. WELTER 2020-09-25 CHECKED BY. DATE PLOTTED: G. HOY 2020-09-25 BIM: ISSUE DATE: A. STEPHENSON 2020-09-25 DRAWING NUMBER'. 8120 -7013 SHEET NUMBER'. TM2 . 01 n LEVEL 1 FLOOR PLAN - SHEETMETAL SCALE: 1/4" = 1'-0" z 0 2 4 8 16 F L �'U) V! L o AREA OF WORK C o l z -J 0 dm O m� 00 toCco zl E Z 21 L-_-_-. J IL� U o s G LL r a 3 V z n a Z r � W O fS'�3b w KEYPLAN Lu 0 AREA OF WORK rL N TM6.01 ' D I 14x14 ON I 60.1 i cu-1 i I I I I I I 0 iRS/RL DOWN TO FCU-1 i U E RTU-9 I I I I iE EF-1 i j =E F- I 12e EA TM6i.01 I i ON I I E EF-2 I I I I I I I I I I I E RTU-11 f— ERTU-6 O C '4�..............................................................00 L.L tea/ W WN QULL Q Ori -j � O U � O 0 0 � g O > O o � O cn CID o (If Z cn ENGINEER. LAST REVISED: J. WELTER 2020-09-25 CHECKED BY. DATE PLOTTED: E RTU-10 G. HOY 2020-09-25 SIM: ISSUE DATE. A. STEPHENSON 2020-09-25 DRAWING NUMBER: 8120- 7013 SHEET NUMBER: E RTU-5 TM2 . 02 ROOF PLAN - SHEETMETAL SCALE: 1/4" = V-0" QI z 0 2 4 8 16 ?� L V! NN Obi 'I OUTSIDE AIR Fs `g 550 CFM EF-10 � ROOF LP-1CL FLANGED CONNECTION 0 m— EQ ou xl W/EPDM GASKET AND MIN. o OF 8 NUTS/BOLTS Q >- 80' E2 Z LL S _U LLH a� 2J xi FCU-1 0 (� Lu 0: MIN.4 DIA. (� (� ? y O R ' LLo N FAN FILTER UNIT--" 830 875 550 b CFMt CFM CFM 4x8 WOOD CURB FLOOR o �o STERILE COMPOUNDING-/ 9 N GARBING ROOF CURB AND FLASHING ' Z m W o HAZARDOUS COMPOUNDING ls� BIOLOGICAL SAFETY CABINET /� 3 SYSTEM DETAILH BIOLOGICAL SAFETY CABINET EXHAUST FAN DETAIL T`� N.T.S. �i N.T.S. O oF_ 3 a ROOFTOP CONDENSING UNIT--\ MIN.4x112"DIA.x3'EMBED V p INTO WOOD CURB,TYP. BOTH SIDES o WOOD CURB BY OTHERS m EXISTING ROOF SYSTEM g J V 2 ROOFTOP CONDENSING UNIT SUPPORT DETAIL TM8.01 N.T.S. BAROMETRIC DAMPER (BDD)(TYP2) AIR VENTS ON TWO CAP SIZE PROVIDE WEATHERTIGHT ACCESS SIDES ONLY.ENDS I PANEL ADEQUATELY SIZE FOR ARE BLANK. ACCESS TO DAMPER WEIGHTS TOP OF ROOF HALF OF CAP SURFACE i i SIZE 7v BIRDSCREEN Fn 8' CANT STRIP AND MIN ROOFING BY G.C. DUCT SIZE INSULATED CAP ROOF IN PER CODE OPNG CURB BY ROOF CUT AND PATCH CURB SIZE MC. (IF REQUIRED)BY G.C. 3 LOUVERED PENTHOUSE ROOF DETAIL T`MB� N.T.S. ♦� vJ J O < Z J LLI Q Q I 0U 0 RSIRL TO CONDENSING UNIT, � ^ O SIZE PER MANUFACTURERSFCU J Q Z LL INSTRUCTION Z O Q Q CN Q T 0 ® 0 Z :r Lu 3 O 0 W (L = Cn ENGINEER LAST REVISED: J. WELTER 2020-09-25 CNEC EDBY: DATEPIOTTED: 2 G. HOY 2020-09-25 BIM: ISSUE DATE: A. STEPHENSON 2020-09-25 1� SATURATED SUCTION LINE WITH TRAP(FOLLOW MFG GUIDELINES) DRAWING NUMBER: 2Q CONDENSATE PUMP 8120- 7013 Q3 FLEXIBLE CONNECTION SHEET NUMBER: ® PROVIDE ALL THREAD ROD.MOUNT UNIT FROM STRUCTURE TYPICAL 4 PLACES O5 NEOPRENE ISOLATOR OR SPRING ISOLATOR W/MINIMUM 1"DEFLECTION T M 6 . 1 TYPICAL 4 PLACES 4 SPLIT SYSTEM (W/CONDENSER) DETAIL TM8.01 N.T.S. x a 'C C'