Plans (48) M EC2020-00184 e�'cel HVAC, INC CONTACT INFO: MAIL.P O.BOX 1188 CANBY,OR 97013 PHONE:(971)930-7194 EMAIL.JEREMY@EXCELHVAC.NET SPLIT SYSTEM SCHEDULE: CCB° 214345 COOLING HEATING ELECTRICAL PROJECT #: TAG MFG. MODEL CONDITION TONS CFM WEIGHT NOTES NETMBH SEER EER NETMBH VOLTAGE MCA MCOP RECEIVED HP-1 CARRIER 25HCE448AO06 NEW 4 48 14 11.5 48 460- 3 8.27 15 197 2020 20-331 HP-2 CARRIER 25HCE448AO06 NEW 4 48 14 11.5 48 460- 3 8.27 15 197 HP-3 CARRIER 25HCE448AO06 NEW 4 - 48 14 11.5 48 460- 3 8.27 15 197 CITY OFTIGARD AH-1 CARRIER FB4CNP048L00 NEW - 1600 - - - - 460- 3 18 25 152 1,2 BUILDING DIVISION W AH-2 CARRIER FB4CNP048L00 NEW 1600 460- 3 18 25 152 1,2 z AH-3 CARRIER FB4CNP048L00 NEW 1600 460 3 18 25 152 1,2LLJ Z NOTES: 0 m Q ~ x 1)AIR HANDLER RECEIVES POWER FROM INSTALLED 15KW AUXILIARY ELECTRIC HEATER ACCESSORY TRANSFORMER I ' 2) MCA RATING REPRESENTS COMBINED AMPS FROMTHE AIR HANDLER AND THE AUXILIARY HEAT KIT li N UX N < w _ 0 FO a LL O LL oLJL 0) Oz O ¢ 0 SHEET NOTES: < o N U cl�w o � o - OUTSIDE AIR IS BEING PROVIDED w LU o r < W z TO SPACE BY (E) 12"0 AIR INTAKE w LU Q_ O Of DUCT. ALL UNITS TO BE TIED INTO � a � (E) O.S.A. DUCT AND SET TO Cn w0 a > Qx Op a MINIMUMS PER OMSC 403.3.2 CODE Z z OUN O L) U) oz AREA OF WORK a 0 r� a z w `in a 0 I__ x OO � U) z UJ W w O (D N Q 00 U) x0 V AB U w U LU0 0 v ww o � JEL r e * w PLEASE CIRCLE ONE: 4 NOT FOR CONSTRUCTION PERMIT SET 0 Ir0 p ,�. ONSITE SET AS-BUILT SET 71nfl ' n ' OFFICE COPY CITY OF TTGARD RENIIED POIt(.JDJL CONIPLIANCE Approved:\N, ] . . • Al OTC: [ ] • . . Pcrluit #: mV '► OaQ- O f I R9 • Address: Suite #: By: Date: 1 <_ ldeation'�r: PACTRUST ADDRESS.15350 SW SEQUOIA PARKWAY SUITE #300 PORTLAND,OR 97224 REVISION: D 8 B B B DRAWN BY: DATE: VALIDITY OF PERMIT Z.T.B. 03/27!2020 THE ISSUANCE OF A PERMIT SHEET NO. BASED ON CONSTRUCTION I VICINITY MAP N DOCUMENTS AND OTHER b10.1 NTS DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM n A O . 1 REQUIRING THE CORRECTION 1\Y/I I OF ERRORS. OSSC 105.4 SHEET NOTES: e 'Cel HVAC,INC 1� POINT OF CONNECTION OF (N) CONTACT INFO: TO (E) DUCTWORK MAIL PO BOX 1188 CANBY,OR 87013 PHONE:(871)830-7184 EMAIL:JEREMYCEXCELWAC.NET CCB N 214345 02 (E) AIR HANDLER UNIT AND DUCTWORK TO REMAIN IN PLACE PROJECT #: 20-331 03 DEMO AND CAP (E) DUCTWORK W ® (N) HEAT PUMP FOOTPRINT U z mQ o '= ZW LL IV U LL N 1 2 3 4 5 Z0 OO oz Qo UX UU1 W � _ _ A - T ~ W zo w ci W Z W Lu a 10"0 P.2 v / O uj z 0 O p F 3 400 CFM 1 6"O • • Ns n 42"X8" Oz d V � O Z U � O cld &i zw 600 CFM O U 42"X8" 12"Q1 CD zd W w N Q B R 12" = S o !L) W Fo o 6� v W 1 g Of T0- 18"X 18" - 4 0 CFM I tr " 12"HSW T • PLEASE CIRCLE ONE: 200 CFM lul 12°X12" 14' 0 NOT FOR • -0- CONSTRUCTION o �'- R 1 Z4 r N = 12" PERMIT SET 'Fr, 7 I VR ONSITE SET - 0 11 3 cu H ))� AH -- — —,----- ��, 110 $ AS-BUILT SET ((tt�i)) Alpm I 8„ X. IN-N 7 1 goo 8„ 1 12" TO (E) 12"0 OUTDOOR AIR 1 O D 611 DUCTWORK F71 8 F5 VsN0 o� S� --- D I I 0 1 I IHP �e 3 4 --� EEJ PACTRU ST 14" 320 ClM I ADDRESS:,5350 SW F 0 P.5 I H P SEQUOIA PARKWAY SUITE L--- --- k3W PORTLAND,OR 87224 V 1 12 Ila REVISION: ---� I I 0 1477. 7±1 "Q1 H p L--- 1 a DRAWN BY: DATE: Z.T.B. 03/272020 SHEET NO. FLOOR PLAN N b1 L� 1,4"=11-o" M 1 . 0 2' I' 0' 2 4' e�'cel HVAC,INC CONTACT INFO: MAIL:P.O.BOX 1189 CANBY,OR 97013 SHEET NOTES: PHONE (971)@EXC93G-7194 LHVA EMAIL'JEREMYEXCEFNAC NET CCB It 214345 REFRIGERANT LINESET PROJECT #: PENETRATION INTO (E) SOFFIT 20-331 r2 (N) AIR HANDLER UNIT w FOOTPRINT o = Zw LJL N 0W 1 2 3 4 5 6 TNMINAL _ 0O oz 12 BAYS AT 25'-0" = 300'-0" 0 < g QN ILL 0 W U Lu � z2 A w z } LU v �* w W LU Be 0. w ~ 0_ U) ° w o 0 � ¢ Q _ O1] O p Q 3 _V N W Be OLL r B Z o_U O Z UU LL F zw Lin z o Ou) o c/) � z W Wo D OD A y0 = o w t O w 3 i AH 1 w � 1 QO C) U a 2 0w oof L_,NESET NESET- INESET-UNESET�IN INESEf�WESET�i1NESET�INEi LINESET-UNESUT UN INESET�INES MII SETS NIM LINESET-LINESETNEV. LWESEf w Lu(tmPLEASE CIRCLE ONE: Na NOT FOR E CONSTRUCTION HP w 2 F_ — --I L — PERMIT SET HP 1 ONSITE SET G AS-BUILT SET H PACTRUST ADDRESS:15350 SW SEQUOIA PARKWAY SUITE #300 PORTLAND,OR 97224 REVISION: 6 - A A A DRAWN BY: DATE: Z.T.B. 03/27/2020 SHEET NO. ROOF PLAN M2 . 0 4' 2' 0' 4' 8'