Plans (65) FPS2021 -00093 O M O # CD O SCOPE OF WORK ADDRESS SCHEDULE FIRE ALARM EQUIPMENT SYMBOL LIST RECEIVED o MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM NO CHANGES NEW EXIST SYMBOL DESCRIPTION PART / ROUGH-IN / NOTE MOUNTING HEIGHT p11C 1 00 c O�� W 0 0 WHICH INCLUDES CENTRAL STATION OFF-SITE REPORTING, HORN/STROBES, AND - 1 FACP FIRE ALARM CONTROL PANEL EXISTING EXISTING EXISTING HU ll SSSIIIJJI sTlzaees. CITY OFT RD LU o 1 NACoI FIRE ALARM REMOTE POWER SUPPLY SILENT KNIGHT EXISTING EXISTING WILDING VISION g Y - � FIRE ALARM REMOTE POWER SUPPLY SILENT KNIGHT SELF-CONTAINED SURFACE MOUNT GENERAL NOTES SK-PS6 20.0"H X 14.5 W X 3.5"D1 ALIGN WITH OTHER EQUIPMENT FAC 1. THE FIRE FIRE ALARM CELLULAR COMMUNICATOR EXISTING EXISTING EXISTING ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH 2019 Z NFPA 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. NoO 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE C SZ CEILING MOUNT HORN/STROBE - WHITE SYSTEM SENSOR 4' SQUARE, 4. OCT, SINGLE OR THAN ONE FLOOR SHALL BE RISER RATED. 6 (NAC AND CANDELA NOTED AT DEVICE) PC2WL DOUBLE GANG BACK BOX CEILING MOUNT 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. C CEILING MOUNT STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4' OCT, SINGLE OR R 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND 18 - o CEILING MOUNT 1 m LIGHTNING PROTECTION DEVICES. ® PLAN NOTES © (NAC AND CANDELA NOTED AT DEVICE) SCWL DOUBLE GANG BACK BOX iftow 6. DEDICATED BRANCH CIRCUITS) AND CONNECTIONS SHALL BE MECHANICALLY m PROTECTED. 1. VERIFY TRIP METHOD 1` 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS rc Q "FIRE ALARM CIRCUIY. FOR NAC 1. a 8. AUDIBLE NJJ2MS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE (2019 NADDED DEVICE �\ NFPA 7z). 2. RELOCATE NAC 1-4 TO a 9. CENTRAL DOCUMENTED MONITORING SHALL BE DOCUNTED UPON COMPLETION i OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.4 (2019 NFPA 72). NAC 2-1. 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH BATTERY CALCULATIONS SECTION 7.5.6.2 (2079 NFPA 72). FIRE ALARM RISER DIAGRAM NOTIFIER SK-PS6 (NAC 2) REVIEWED/APPROVED: EXISTING DEVICES PART / DESCRIPTION QTY STANDBY STANDBY TOTAL HARM HARM TOTAL EXISTING DEVICES PSE-6 MAIN CIRC. BOARD (4.7K EOL) 1 0.1390 0.1390 0.1570 0.1570 SITE EXISTING WIRING (VERIFY TYPE AND LOCATION) N2-1 NOTIFICATION 1 0.0000 0.0000 0.5410 0.5416 N2-2 NOTIFICATION 1 0.0000 0.0000 0.6300 0.6300 N2-3 NOTIFICATION 1 0.0000 0.0000 0.8160 0.8160 BEN BREIT-4460LEA SLC i EXISTING EOL,�8DkO N2-4 NOTIFICATION (SPARE) 1 0.0000 0.0000 0.0000 0.0000 <• N2-5 NOnFICAnON (SPARE) 1 0.0000 0.0000 0.0000 0.0000 (EXISTING) FAC PHONE 2 EXISTING EOL DkO > P��pP9 FACP a STANDBY TOTAL 0.1390 HARM TOTAL 2.1440 (EXISTING) 7 EXISTING EOL DkO a < JQQ(il NAC-0 a 'CALCULATIONS BASED ON 24 HR STANDBY TIME d� 5 MIN ALARM TIME' a n F" O 2 EXISTING EOL eDkD AMPS (A) X TIME (H) AMP-HRS (AH) 20% DERATE STANDBY 0.1390 X 24 - 3.3360 3: N 120VAC DEDICATED E%ISTING WIRING ALARM 2.1440 X 0.0833 0.1787 - TOTAL AH = 3.5147 4.2176 BATTERIES TO BE INSTALLED: (2) 12Y 7.0 AH TRIP 1 E%ISTING EOl e7kD SILENT KNIGHT 2-EXISTING-------EOL e7kD 5495 �Z(EXISTING) � CSI EOL .7kO A NOTIFICATION CIRCUIT SCHEDULE VOLTAGE DROP CALCULATIONS 4 CKT , DEVICE LOCATION / AREA CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT RELOCATED FROM ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP X 120VAC DEDICATED NAC 1-4 NO-1 EXISTING EXISTING (MAX ASSUMED) FACP 0.000 100 14 0.00 20.40 YES 0.00% W NO-2 EXISTING EXISTING (MAX ASSUMED) FACP 1.500 300 14 2.76 17.64 YES 13.54% TRIP/SYNC C A C NO-3 EXISTING EXISTING (MAX ASSUMED) FACP 1.500 300 14 2.76 17.64 YES 13.54% Z (TB_5) 1 j--�o;r--j o Eout.7kO NO-4 EXISTING EXISTING (MAX ASSUMED) FACP 1.500 300 14 2.76 17.64 YES 13.54% 'A 4.7kO EOL a (TB-6) 2 -��-- 0 --� EOL 4.7kO NI-1 EXISTING EXISTING (MAX ASSUMED) FACP 1.500 300 14 2.76 17.64 YES 13.54% v, 4.7kD EOL (TB-7) a N1-2 EXISTING EXISTING (MAX ASSUMED) FACP 1.500 3DO 14 2.76 17.64 YES 13.54% e SILENT KNIGHT 3 EOL 4.70 N7-3 STROBES, HORN STR08ES HNR CLUB FOR MEN TI SPACE FACP 0.582 440 14 10.931 19.47 YES 4.58% Q SK-PS6 N1-4 TRIP BOOSTER 2 TRIP FACP 0.010 20 14 0.00 20.40 YES 0.01% 1 1 1 NAC-2 4 SPARE EOL 4.7k0 ■ • ■ w • N2-1 STROBES, HORN STROBES HAIR CLUB FOR MEN T SPACE FACP 0.541 435 14 0.88 19.52 YES 4.32R W 5 SPARE EOL g7kD N2-2 STROBES. HORN STROBES NW INTEGRATIVE MEDICINE FACP 0.630 410 14 1.01 19.39 YES 4.95% N2-3 STROBES, HORN STROBES NW INTEGRATIVE MEDICINE FACP 0.816 470 14 1.44 18.96 YFS 7.04% //1 120VAC DEDICATED N2-4 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% U) N2-5 SPARE SPARE FACP 0.000 0 74 0.00 20.40 YES 0.00% W` ....POINT TO POINT METHOD OF CALCULATION / cA ADJUSTED CIRCUITSAPPROVED REVISION F- Y N ui DETAIL N OFFICE CO. lk. a z Q PLEASE PROVIDE �1� cn 0 COMPLETED NFPA 72 V Lu O J 0 0 1IFFICIF COPY COOF ERD MPLETION AT U)RECORD OF LU z 0 0 o O oo O CM OF TIGARD� FINAL INSPECTION Z z z FROM NAC SOURCE TO NEXT DEVICE FOR CODECOMPLIAl' a ALARM OPERATIONAL MATRIX O g 5 PREVIOUS DEVICE EOL(4.7KO) APP QI� (yJ O 0R 0R SYSTEM OUTPUTS � � NAC - NAC - :. OT •f. NAC IN NAC OUT q" _ �� a� O a (TTPICPL iN1C) (ttPICFLINC) ` p Sia J SP NAC + NAC + � 4 �p0 Pte,`' �2 DWG REV. / DATE Ad 9: �,< 2 h `la 5�" Py5 a`� yh� 0 08/04/21 Suite 1 0. OA 08/11/21 $� DaftZO c� , tp°� �p FrcQcR�° 5 y��' �eSA o OO DRAWN BY: CAUTION: SYSTEM INPUTS J DO NOT LOOP VARE UNDER NOTES: JJR TERMINAL 1. SYSTEM SENSOR EXISTING ALARM CONDITIONS BREAK WARE RUN TO PROVIDE UNIVERSAL MOUNTING PLATE EXISTING TROUBLE CONDITIONS CHECKED BY: SUPERVISION OF CONNECTIONS. SW,P2W,SCW,PC2W,P2RK EXISTING SUPERVISORY CONDITIONS • • BJB L-SERIES:SWL,P2WL, LOSS OF AC POWER AT FACP • • FILE NAME: SCW&,PC2VM_ OPEN CIRCUIT FA.dwg DISCONNECTION OF BATTERIES STROBE AND HORN /STROBE GROUND FAULT . . DRAWING#: NOT TO SCALE PRESS SIGNAL SILENCE KEY • • FA-1 PRESS RESET KEY ORIGINAL SHEET SIZE:17'x 22" #OF DWGS IN SET: SHEET 1 OF 2 opo 0 HATCHED AREAS O I 04 NOT IN SCOPE p ro / WLoLuutto wv�iv YO 3W t,1 Y U) cc m w a a56R 1--� CONSULT CONSULT ONSULT CONSULT (E) I E251 EHI ,26 NFAC (E) N2-2.2 N2-2.6 2-2.7 N2-2.9 FROM PSE-8 1SCD 15CD 75CD 15CD N2-2.11 FRCP (E) PROVIDER OFFICE NAC (E) I NAC 2.2 FL 1 C 120 Ittw R3 C o O o C o 126 O o C EOL d DOC (E) ° N2-2.'—MOM ° VERIFY I NAC 2.3FL 1 o N2-2.3 CIRC. C J 15CD ° 100 ILLOCAPON c 12, N2-2.10 LOBBY/WAITING 15CD "'-' --- _.- ___. .....-._._. -_. _ _ _ 100 - - N2- .4 �- N2--12.5 N2 02.8 — — 15C 127 (2), 150D 129 �__�75���� 3 2 EXAM 11 RECEPTIO///Jjy'',,,\�� N2-3.1 12 1 8 129 I 101 y \ 30CD c W ° - - - —M4 - - - - - - Z I— ' 1 e ,1a EXA 6 M5 EXAM 4 U v, 11 1 s tta ADMIN OFFICE - C - -i �W2– � D N2-3.10 L EXAM 7 C o C ° 75CD C C o toa 5 qr V/ ��/'� „e i� 2-3.2cy ° 15t 11 N25CD ` CIRC. c 15CD � /} N2-3.7 107 C EOL ADMIN OFFICE ''^^ 75co 1oa VJ ❑ 0 C 0 ---00 o CIRC. C03 – N2-3.8 – .9 ___.. _N2-3.12 105 O _.._—. � _ � w 11 75co m CIRC. Isco 75CD 1 RR 10G Y (n N2-3.3 IT,10 109 N v 014K 15 DURE ❑ LAB ° 1os 161 Q I� ,,, ,06 ,t^^ d O ADMIN OFFICE V LU Ur L"�J L L J t10 1°4 Lu LU K O O 5 T REA IR LAT EN --- N / O Z) \ P AP S V L K t Z m / ww O Z XO 00- DWG o_DWG REV. / DATE 1 FLOOR 1 ° 4' 8' 16 oA 08/11/21 SCALE: 1/8"=l'—O" DRAWN BY: JJR CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#: FA-2 ORIGINAL SHEET SIZE:lrx 22' #OF DMS IN SET: SHEET 2 OF 2