Plans (40) BUP2022 -00052
OFFICE COPY RECEIVED
FEB 2 2 2022yr,
CITY OF TIGARD ���,
BUILDING DIVISION
Y
I r
GENERAL NOTES e� 9 ' OF 0
I. THESE PLANS FOR TENANT IMPROVEMENT ONLY. ■ ■ ■ E rl Ejo
O•o o
2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, E
PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST E JILI _
TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OFOFFICE E �E N
THE PROJECT IN COMPLIANCE WITH THE APPLICABLE E 08 OLF. = 150 I Q o• OO t`
GOVERNING BUILDING CODES AND REGULATIONS. WHERE 120 SF. / 150 1 �r
MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND
SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT IS THE E = OCCUP. E 1 N
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO F
DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC +i- O• �+ t+
MATERIALS AND DETERMINE CONSTRUCTION DETAILING, I
ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, [� -q w 0�
REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS • • Z
AND METHODS OF INSTALLATION- IT IS THE CONTRACTOR'S +.46i OIO •. 0 w
RESPONSIBILITY TO ASSURE TWAT ALL CONSTRUCTION IS IN
COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS.
3, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL d UI
MEANS,METHODS, TECHNIQUES AND SEQUENCES OF _
CONSTRUCTION INCLUDING JOB SITE SAFETY. THE ■ E E � WO ROOM
ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, OLF. • 150 O
METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION EXISTING 2X4 T-BAR I 109
INCLUDING JOB SITE SAFETY. CEILING g9'-5" AFF_ 293 SF. / 150 I E ( py
= 2 OGGUP.
4. THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE E
ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT,
AND SERVICES NECESSARY FOR AND REASONABLY
INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION NV OFFICE E — — — — ~
WORK IN CONNECTION WITH THE DOCUMENTS. E 0� OLF. = ISO EX S7INCs I E 4 1. +38" 0 �
44 SF. / 150 34" HIGH 446
5. APPLICABLE CODES ON MATERIALS AND WORKMANSHIP E I OCCUP, COUNTER
SHALL CONFORM TO THE 2019 OREGON STRUCTURAL
SPECIALTY CODE AND APPLICABLE STATE AND FEDERALI 1 k
SAFETY ORDERS. ALL REFERENCES TO CODES, 0 E
SPECIFICATIONS, AND STANDARDS SHALL MEAN AND ARE ® E �Q C
INTENDED TO BE THE LATEST EDITION, AMENDMENT It ,
G TION WAITING
AND/OR REVISION OF SUCH REFERENCE STANDARD IN
EFFECT. O
I L 1 _ a F
6. EACH SUB-CONTRACTOR (OR THE GENERAL CONTRACTOR
WHEN HE IS PERG FORMINSPECIFIC PORTIONS OF THE 0 64 SF./ 150 46 SF. / -7
= =
WORK) IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE I OCCUP. 1 OCCUP.
FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, E E E
NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF , E
ANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE LLW
THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT Fni/I
MEET CURRENT LOCAL BUILDING CODES,
1, THE CONTRACTOR SHALL VERIFY AND CONFIRM ALLNEW COUNTER XISTING RECEPTION
DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE DOOR/SDELITE (' �
DRAWINGS AND SPECIFICATIONS AS WELL AS THE ASSEMBLY RELOCATED RELOCATED
PHYSICAL CONDITIONS OF THE SITE, NOTIFY THE ®� ■ DOOR/SIDELITE DOOR/SIDELITE—
TOMATCH W
ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK, Z. E OFFICE SUITE ASSEMBLY ASSEMBLY [li
8. DIMENSIONS ARE FROM FACE OF FINISH MATERIAL. 106 OLF. . 150 STANDARD F� W
E 18sp./ 150 __ 111
S. PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY 2 OCCUR
NEW WORK TO EXISTING CONDITION OR NEW CONDITION, SII 1 II I Q
WHICHEVER IS APPROPRIATE. 20" \ I I II r 1 tD r
10, EACH SUM-CONTRACTOR MUST REFER TO DIAGRAMMATIC ■ ■ ■ N \ I1 I 1 Dl N Z rv� U.I
PLANS AND SECTIONS AND MUST COORDINATE THEIR WORD I E JI L W Z
WITH ALL TRADES TO AVOID CONFLICTS. - i i " � �1 Z 6
11, DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF • E
SECTION 10043 - OREGON STRUCTURAL SPECIALTY CODE r n 1 I I I O C Q
AND SHALL BE EITHER A LEVER OR PANIC TYPE
REQUIRING ONLY A SINGLE MOTION TO OPEN-KEY-LOCKING r 1-17 r 1--I ' 1 1 I per„ a Q O
HARDWARE MAY BE USED ON THE MAIN DOOR OF B,F,M r n, r 1--I E OLj OLF. = 150 �'!4 �-� I(jJ3 OLF. = 150 I{jJ2 OLF. 150 '�
91 SF. / 150 131 5F, / 150 124 SF. / 150 E
OR S OCCUPANCIES ONLY, WITH THE UNLOCKED DOOR E = I OCCUP. OFFICE I 1 = I OCCUP. I OCCUP_ M w N
FREE TO SWING WITHOUT OPERATION OF ANY LATCHING LUJ LUJ 104 O_L- F.-/ Ism I I E E r� 0
DEVICE AND A READILY VISIBLE DURABLE SIGN POSTED ' �I--1� -I—I-� = 1 OCCUR r
ST THNEGRESS
DO SIDE
OR TO REMAIN UNLOCKED WHEN BUILDING LUJ L LJ J® I I E Z ryw� V
IS OCCUPIED". THE SIGN SHALL BE IN LETTERS I" HIGH ON I I I+1 Q
CONTRASTING BACKGROUND. I I ,+1
12. PROVIDE TEMPERED GLAZING AT WINDOWS 4 RELIGHTS I I E N m
PER SECTION 2406 - OREGON STRUCTURAL SPECIALTY E
CODE. TOP OF RELIGHT FRAMES TO MATCH TOP OF DOOR
FRAMES. vp
13. VERIFY KEYING REQUIREMENTS WITH TENANT AND
LANDLORD.
14,PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE
MARSHALL AT WALK-THROUGH. REFLECTED CEILING PLAN I ST FLOOR PLAN
15.MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE
PERMITS. 1Q° • I'—m" "4n _ I.—ou
02--la-22
LEGEND SCOPE OF WORK
EXISTING WALL TO REMAIN NEW TENANT AT EXISTING SUITE_ CONVERT
• EXISTING SPRINKLER HEAD (2) PRIVATE OFFICES TO (3) PRIVATE OFFICES.
_ _ _ _ _ _ _ EXISTING WALL TO BE REMOVED BALANCE OF SUITE TO REMAIN AS-BUILT_
PROVIDE SOLID BLOCKING BETWEEN
TOP PLATE OF JOISTS_ FASTEN NEW WALL - 31" METAL STUDS s ■ EXISTING HVAC_ RETURN CODE SUMMARY
MTL_ STUD BRACING TO BLOCKING_ 24" O.C. N." GYP, BD. EACH SIDE
USING (4) 08 SHEET METAL SCREWS GENERAL BUILDING DESCRIPTION: GENERAL OFFICE
NUMBER STORIES_ 2
20 GA, 358" METAL STUD BRACING TO EXISTING DOOR TO REMAIN EXISTING HVAC DIFFUSER FIRE SPRININ KLERS: 100% COVERAGE
ROOF STRUCTURE AT 6'-0" O.G. BUILDING SIZE: 48,000 SF,t
ALTERNATING DIRECTIONS. FASTEN OCCUPANCY: B
BRACE TO TOP OF STUD W/(2) 08
CONSTRUCTION TYPE: III-B
Es. / EXISTING 2X4 FLUORESCENT FIXTURE TO
SHEET METAL SCREWS AT EACH END_ II REMAIN TENANT SPACE SIZE: 1, 41 USF t
EXISTING DOOR TO BE REMOVED TOTAL OCCUPANT LOAD 18 OCCUPANTS
"LL BRACING TO BE PROVIDED WHERE
DISTANCE BETWEEN PERPENDICULAR I rl—F—I-1 T 1 EXISTING 2X4 FLUORESCENT FIXTURE TO
INTERSECTING WALLS OR HORIZONTAL E CL1:3:� BE REMOVED OFFICE COPY
EGRE55 BRACING BETWEEN WALLS EXCEEDS L L LU-JJ
WITH
BIA TERY BACK-UP 6 _m. °r_• CITY OF TIGARD,. _
TYPlcau NEW OR
WI RELOCATED DOOR ® EXISTING 24 HOUR NIGHT LIGHT CIRCUIT D FOR CODE COMPLIANCE
Ell dol o SUSPENDED CEILING 3'-0" WIDE (VERIFY HEIGHT)
0 rN AP� l
OTC:
�sv o v o s1� o11
ATTACH BRACE DIRECTLY �{E EXISTING DUPLEX ELECTRICAL OUTLET E.S. EXISTING ILLUMINATED EXIT SIGN WITH T
TO STUD_ H TO REMAIN BATTERY BACK-UP TO REMAIN Pctmk#: 13Ur3AO a..-L- oQQg�, COPYR314T LAW
PROTECTSAd&e�. �`��� Sw �� �� ROTEGTS THE DUPLICATION
��}, EXISTING DUPLEX ELECTRICAL OUTLET OF DRAWINGS WITHOUT
O s,8�• GYP_ BD_ EA. SIDE T1 TO BE REMOVED Suite#9 � 6) THE OWNER'S CONSENT_
11 NOTE: HVAC DIFFUSERS 4 RETURNS SHOWNDatet RE-USE OF ARCHITECTURAL
�IIII ONLY IN EXISTING LOCATIONS FOR E�' 3 - �y-2 DRAWIN-s WITHOUT A
3 25 GA METAL
STUD AT 2'-0" O.C. NEW DUPLEX ELECTRICAL OUTLET CONTRACTORS CONVENIENCE. IS POI-451T RELEASE
BOTTOM OF COVER PLATE TO BE AT Is PROE•IBITED
15" AFF_ (U)ON,) DIFFUSERS AND RETURNS TO SATISFY
BUILDING, MECHANICAL AND FIRE CODE
Es. BOTTOM TRACK TO FINISH + TOISTING REMAIN 4-FLEX ELECTRICAL OUTLET VALIDITY OF 054 "12001
AREA OF FLOOR W/HILTI 'X-U' 0,15-l" 0 X 3/4" THE ISSUANCE OF A PERMIT
WORK EXISTING ILLUMINATED EMBED gib" O_C.
Exlr SIGNS WITH E EXISTING MUDRING AND PULL WIRE BASED ON CONSTRUCTION
BATTERY BACK-UP CONCRETE SLAB. v TO BE REMAIN DOCUMENTS AND OTHER
(TYPICAL) DATA SHALL NOT PREVENT
IST FLOOR KEY PLAN - EXISTING MUDRING AND PULL WIRE TO THE CODE OFFICIAL FROM
BE REMOVED REQUIRING THE CORRECTION
OF ERRORS.OSSO 105.4
NOT TO SCALE NEW MUDRING AND PULL WIRE FOR
TENANT PROVIDED PHONE AND DATA
v WIRING_ BOTTOM OF COVER PLATE TO
WALL DETAIL BE AT 15" AFF_ (U.ON.)
OF I