Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (38)
BUP2022 -00050 RECEIVED FEB 0 2 2022 CITY OF TIGARD F BUILDING DIVISION TP03 %6 � � .LISC#2 GENERAL NOTES 9?� OF I. THESE PLANS FOR TENANT IMPROVEMENT ONLY. 8_ DIMENSIONS ARE FROM FACE OF FINISH MATERIAL, E E E E E exr. )ATF 12/31/2022 E E ! 2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, S. PATCH AND REPAIR ALL EXISTING WORD DAMAGED BY E E E E E e E E E PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST NEW WORK TO EXISTING CONDITION OR NEW CONDITION, E E I TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF WHICHEVER IS APPROPRIATE. 00N THE PROJECT IN COMPLIANCE WITH THE APPLICABLE GOVERNING BUILDING CODES AND REGULATIONS. WHERE 10.EACH SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC I MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK 4 SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT IS THE WITH ALL TRADES TO AVOID CONFLICTS. E II E RESPONSIBILITY OF THE GENERAL CONTRACTOR TO M Q m DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC II. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF iii 0 kn 0 MATERIALS AND DETERMINE CONSTRUCTION DETAILING, 055C SEC, 1004.3 AND SHALL BE EITHER A LEVER OR ____ _ y _ __ ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, PANIC TYPE REQUIRING ONLY A SINGLE MOTION TO OPEN. - W �, 1i �r� p e E Q u" REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN /� I3li I w II r E AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S DOOR OF B, F, M OR S OCCUPANCIES ONLY, WITH THE 6== i �I L ILL,% RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS IN UNLOCKED DOOR FREE TO SWING WITHOUT OPERATION OF -- ��------------J I +I rT ---- COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. ANY LATCHING DEVICE AND A SIGN REAPING "THIS DOOR u `\ i iii----------- MUST ---___---MUST REMAIN UNLOCKED DURING BUSINESS HOURS" ° �I II M Wi Ali h=----- � -------- _____j_-�L---------- 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL PLACED ON OR ADJACENT TO THE DOOR II -- -___-__ _-___-___ 1 _ ___ _ I 0 Ir____ .0.___ F== � r___ �__ I I MEANS, METHODS, TECHNIQUES AND SEQUENCES OF E I+ w N I I Iy II I + a CONSTRUCTION INCLUDING JOB SITE SAFETY. THE 12, PROVIDE TEMPERED GLAZING AT WINDOWS t RELIGHTS , ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, PER SECTION 2406 STATE OF OREGON STRUCTURAL II Til --------- ' I I I __�------ 7_ I I METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION SPECIALTY CODE_ TOP OF RELIGHT FRAMES TO MATCH II III ------- I I I INCLUDING JOB SITE SAFETY. TOP OF DOOR FRAMES, is iii E Wi I - n ql --------- �+ O 't E 4. THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE 13. VERIFY KEYING REQUIREMENTS WITH TENANT AND E r _ —'I I iL------ --- O ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT, LANDLORD. EAWE it I �4 `�--_-__- E oc 0� AND SERVICES NECESSARY FOR AND REASONABLY I + I III fV INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION 14, PROVIDE 311/2" UNFAGED BATT INSULATION AT ALL NEW E M N� -J ii ���� 0 ply \ m WORK IN CONNECTION WITH THE DOCUMENTS_ WALLS. ----------�--------L------UI 1/p 5. APPLICABLE CODES ON MATERIALS AND WORKMANSHIP 15. PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE I�`\ ii , +i ;I jj O SHALL CONFORM TO THE UNIFORM BUILDING CODE AND MARSHALL AT WALK-THROUGH. \1 ��II `\\ 1/j / II a F:4 APPLICABLE STATE AND FEDERAL SAFETY ORDERS. ALL E d ;!p I M W REFERENCES TO CODES, SPECIFICATIONS, AND STANDARDS 16.MEGHIANIGAL, ELECTRICAL AND PLUMBING BY SEPARATE L� SHALL MEAN AND ARE INTENDED TO BE THE LATEST PERMITS. EDITION, AMENDMENT AND/OR REVISION OF SUCH E E REFERENCE STANDARD IN EFFECT. 1-1, CABINETS TO BE OF 3/4" MELAMINE CONSTRUCTION. EUROPEAN CONSTRUCTION (NO FACE FRAMES) ALL i� c ----- 6. EACH SUB-CONTRACTOR COR THE GENERAL CONTRACTOR EXPOSED EDGES TO HAVE EDGE BANDING. PROVIDE Mi [________ WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE BLUM -15M5580 CONCEALED 125' HINGES AND BLUM 3/4 Ali i I WORD IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE EXTENSION DRAWER SLIDES. 100 LB RATING AT FILE it FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, DRAWERS. 50 LB RATING AT ALL OTHER DRAWERS. BACK ^ I NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF SPLASHES AT COUNTER TOPS TO BE CONSTRUCTED OF 3/4" ANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE MATERIAL, ALL EXPOSED SURFACES TO BE COVERED it THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT WITH P.LAM. SUBMITTAL REQUIRED. E E 11/ ; I" MEET CURRENT LOCAL BUILDING CODES. Vi h---� N 18, PROVIDE BUILDING STANDARD CARPET TILE 4E IL___IV. __� �______ r� a N 1. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALLO �I ,r DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE IS. PAINT AL WALLS DRAWINGS AND SPECIFICATIONS AS WELL AS THEoz O PHYSICAL CONDITIONS OF THE SITE, NOTIFY THE ! ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK II ii II w x Q dN E > 2 W PI 1.-4 (o E� U) U) Z .D4 ' as U c:l, r z 7Q x E +fl z O E u ^^ C E E E FE Ell, E E E E E SECOND FLOOR DEMO PLAN 10/03/21 REVISED 10/13/21 PRICING 11/22/21 REVISED PRIDING LEGEND 01/20/22 CHANGES SCOPE OF WORK REMODEL PORTION OF 2ND FLOOR EXISTING TENANT SPACE 01/31/22 TENANT EXISTING WALL TO REMAIN FOR NEW TENANT. CHANGES EXISTING WALL TO BE REMOVED 02/01/22 TENANT GHANCx;=S EXISTING DOOR TO REMAIN CODE SUMMARY PERMIT ❑ NUMBER OF STORIES: 02/02/22 02/02/22 SUBMITTAL DOOR TO BE REMOVED OR FIRE SPRINKLERS: 100% COVERAGE AREA OF e RELOCATED BUILDING SIZE: 35,000± WORK FIRE ALARM: YES CONSTRUCTION TYPE: V-B OE EXISTING DUPLEX ELECTRICAL OUTLET TENANT SPACE - 6,565 USF. ± H TO REMAIN PREVIOUS OCCUPANCY: B (OFFICE) PROPOSED OCCUPANCY: B (OFFICE) /+CE EXISTING DUPLEX ELECTRICAL OUTLET OFFICE COPY TO BE REMOVED e e e e CITY OF TIGARD„ E EXISTING 4-PLEX ELECTRICAL OUTLET REVIEWED FOR CODE COMPLIANCE COPYRIGHT LAW \N TO REMAIN 'ApptOve& ] PROTECTS THE DUPLICATION OF DRAWINGS WITHOUT l THE OWNER'S CONSENT. EXISTING 4-PLEX ELECTRICAL OUTLET OTC: ( ] RE-USE OF ARCHITECTURAL L 70 BE REMOVED Pew _ DRAWING WITHOUT A �SL� Q COPYRIGHT RELEASE E EXISTING MUDRING AND PULL WIRE Addms: U77 7 y© $ plkvt 15 FiROH15ITED FOR TENANT PROVIDED PHONE AND Suitef. DATA WIRING TO REMAIN • R EXISTING MUDRING AND PULL WIRE FOR Date: LL8_Zll 05,4 "21051 TENANT PROVIDED PHONE AND DATA WIRING TO BE REMOVED VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION ® ® DOCUMENTS AND OTHER DATA SHALL NOT PREVENT KEY PLAN THE CODE OFFICIAL FROM THE THE CORRECTION NOT TO SCALE OF ERRORS. OSSC 105.4 10F4 ! 46 r P'V E I LTJ E I 7� YTfR"veLL --!sL N PATH OF 1EXP.DATE 12/318022 E PROVIDE ELECTRICAL OUTLET ANDDATA PORT INSTALLED EITHER ON O ,--i10'-5" 5'-0" 4'-0" DROP CEILING TILE OR ON WALL 9" NFROM DROP CEILING N REL TE RECITE 00 25 3 1, f\ MI III MI III III VIII II m 4 I1wd,r II --l i,_�y ii�y u��l ui�y4 mm Lfr2EJ ! r N 3„ W 3 O to I OJI Q3JN clow03 of -• 15 E 11�-l L 21m bp-/15 CPT L.V.T. p- (//4�\\ '//4�\1 I//Y�\1 (//�4'�\' sy 0 OLF.• 14 occuP_ tµ. 6l4 L�IIGGEE � 1�-� 5e Occup, s 4 m =y _ PROVIDE ELECTRICAL= f"1 III -I II III OUTLET AND DATA (- -� e�i^`` '3 w E E -/ l�-yJ -y)PORT INSTALLED L-�i na INSTALL WATER / j a EITHER ON DROP CEILrZ _ 1 LINE FOR TENANT'S f E 11 -]TILE OR ON WALL 9" (- 1 -TWATER COOLER �-__ `- g,_0" g'-5" - FROM DROP CEILING L-; ll f'L i n 200 E =y t ! y N ~ 230 2ags ^' E E a A )( O n E 'Q V S II N E � N DIAGONAL - 135'-g" 0 SEPARATION OF EXITS 1/ 3 THE 4 10 E E DIAGONAL (SPRINKLERD BUILDING) O 230 MIN.SEPARATION 135'-S"/3 = 45'-3" O tr) F12—cil ❑ or-EXIT9 112 28 12'-6" 9 ..., SEPARATION yw b NANT A SF. OFFICE- 5335 SF.(01F, = 150) = 36 OCCUPANTS WAITING 201 - 614 SF.(OLF. - T) - 96 OCCUPANTS STAFF CONE,ROOM 203 - 210 SF.(OLF, - 15) = 14 OCCUPANTS 2 WAITING - 201 BENCH SEATING ELEVATION BREAK ROOM 205 - 346 SF,(OLF. - 15) . 23 OCCUPANTS HO Q 9 TOTAL OCCUPANTS - 169 OCCUPANTS E E B P-4 M EJL0164 21 s e Q N zHy 1�-� �-1 O Z 21 SOT ®� 3F OTE W Fr•I-1 I—I d (V O E E ` 2 W E 9 O H1 F— WO' df 22 �i 0 0 dLoED Q E Z) q E aJ 1Ly-•1 U .V�FJ U) :J E Pl E Q, Q V N1— 22 ,z, xj L.L ftO E E E P'-1 ll E E E 21-211 SOLIDCORE SECOND FLOOR PLAN WOOD DOOR 10/03/21 FINISHES LEGEND REVISED PRICISOLID CORE WOOD 10/13/21 EVIS Cx v DOOR 634"! O.C- SOLID SURFACE: CAESAR STONE - CHOOSE FROM ESSENTIALS, EXISTING WALL TO REMAIN STANDARD OR PREMIUM SERIES REVISED 11/22/21 PLASTIC LAMINATE: CHOOSE FROM WILSONART, NEvAMAR NEW WALL - 35/B" METAL STUDS aT 2411 PRICING OR PIONITE BRANDS O.C. 5/a" G T'P. BD_ EACH SIDE TENANT ° NEW I-HR WALL - 3%9" METAL STUDS 9 24" 01/20/22 CHANGES CARPET: PATCRAFT RATIONAL - CHOOSE FROM LOGIC, REASON O-C, 5/a" GYP, BD, EACH SIDE OR SKILL PATTERNS. TENANT 01/31/22 CHANCES �_y.T_ RESILIAN7 PLANK- PATCRAFT TIMBER GROVE II - 20 MIL. VCT: ARMSTRONG STANDARD EXCELON - CHOOSE FROM IMPERIAL EXISTING DOOR TO REMAIN 02/01/22 TENANT WAITING - 201 BENCH SEATING TEXTURE, MULTICOLOR, OR RAVE. CHANGES IT 1 NEW OR RELOCATED DOOR PERMIT 11/2 RUBBER BASE- MANNINGTON COMMERCIAL 4" 3'-0"x0'-0" U.ON- 02/02/22 SUBMITTAL AE EXISTING DUPLEX ELECTRICAL OUTLET YY TO REMAIN NEW DUPLEX ELECTRICAL OUTLET SUSPENDED SINGLE LINE UPPER TRACK E EXISTING 4-PLEX ELECTRICAL OUTLET MOUNTING BRACKET: THE BRACKETS ARE TO REMAIN TO BE DISTRIBUTED TWROUGHOUT THE UPPER TRACK WITH A MAXIUM SPAN OF E EXISTING MUDRING AND PULL WIRE TO A STRUCTURAL MEMBER WITHIN THE SPACING IN BETWEEN AND SECURED ♦ FOR TENANT PROVIDED PHONE AND TO WALL.PROVIDE SOLID BLOCKING TO ACCOMODATE. DATA WIRING 70 REMAIN COPYRIGHT LAW PROTECTS THE DUPLICATION NEW MUDRING AND PULL WIRE FOR OF DRAWINGS WITHOUT THE OWNER'S CONSENT_ TENANT PROVIDED PHONE AND DATA RE-USE OF ARCHITECTURAL WIRING TO REMAIN DRAWING WITHOUT A COPYRIGHT RELEASE T2" X 24" TRANSOM48" X 24" TRANSOM PAINT GRADELL IS PROHIBITED (TOP OF TRANSOM (TOP OF TRANSOM DOORS_TO a BE PAINTED \ \ \ \ \ AT 8'-0' AFF.) AT 5'-0' Ar-F-) BY GENERAL OBA #21051 TYPED TYPED CONTRACTOR y 1 20 MIN DOOR AND 24" SIDE LIGHT 48" SIDE LIGHT 15" SIDE LIGHT 46" SIDE LIGH FRAME ASSEMBLY (TEMPERED GLAZING) (TEMPERED GLAZING) (TEMPERED GLAZING) (TEMPERED GLAZING) 41-011 1 TYPE® TYPE® TYPE© TYPEQ TYPE TYPE TYPEQ A� 2 OF 4 qTIE U GND, R LISC#2 �' OF EXP.DATE 12/31/2022 O pprq N r CT � _ N NEW WNEW N % % I E= O O ® O ,�, O O O O O ® O IM EA O IF I y� I O y0 0 0 0 0 s r., O R tj i etc I - -- -- - �- - -- -- i i •. .L;•cC{fi,.y,.LL:.�Y.gtQcit.� j - 1 O ip spi; ; ; i: ;:cr: ;: ;::: / b -9 � r:.`Ys,�:<:}:�`;:C•::#�: Y : I Orr NJ O O O O E W E W M O 1 O - - 0 1 i - 1 I 1 IL L-L 11 T I T _ yERAI'LOCATION!F MAMlAN I-NR RAT _ o i i i Q o ® I - GI.EdIC fYJQOP111LIG1ft8 dT"NCL MID T_ MID P@mANf LbHTMG YVIENA4! O Q O 1 / jl( O O _ 1 / R ��// C r�• Q N pTV ill I p i FELT. {..4 LL__L I I / [////I- nlcurt ro sTxowo \\ 11 1 \\ f-I 1~i( O / MIKVl NY11R LtlNf \ /Cy 1 , � Q = NQ' / W 11 o . ° i ° 0�. i--1 � CoO O Z x O O O 2 W NOTE: AT AREAS WITH NEW LIGHT FIXTURES TO OBSERVE 11 ALL ENERGY CODE REOUIREMENTS / J L =L / i REFLECTED CEILING DEMO PLAN REFLECTED CEILING PLAN 10/03/21 I,B Ii a I'_mN I/8" a 1'-0" 10/13/21 REVISED PRICING LEGEND 11/22/2' PRICING EXISTING SPRINKLER HEAD LOCATION TENANT 20 CIA, 311/2" METAL STUD BRACING TO EXISTING ILLUMINATED EXIT SIGN WITH 01/20/22 CHANGES /' ROOF STRUCTURE AT 4'-0" O_C, EXISTING HVAC. RETURN ES o ALTERNATING DIRECTIONS. FASTEN BATTERY BACK-UP TO REMAIN TENANT BRACE TO TOP OF STUD W/(2) •8 ® EXISTING ILLUMINATED EXIT SIGN WITH 01/31/22 EXISTING HVAC DIFFUSER ES CHANGES " SHEET METAL SCREWS AT EACH END. `� BATTERY BACK-UP TO BE REMOVED TENANT BRACING TO BE PROVIDED WHERE © EXISTING 2X4 FLUORESCENT NEW NEW OR RELOCATED EXISTING 02/01/22 CHANGES DISTANCE BETWEEN PERPENDICULAR 12ea VERT, WIRE SUPPORTS FIXTURE TO REMAIN E5 � ILLUMINATED EXIT SIGN WITH INTERSECTING WALLS OR HORIZONTAL g 4'-0" O,G. EW. TO MAIN r---�� EXISTING 2X4 FLUORESCENT BATTERY BACK-UP 02/02/22 PERMIT BRACING BETWEEN WALLS EXCEEDS RUNNER E o 8 MAX, FROM WALL 8"MfA '�_� FIXTURE TO 4 F REMOVED SUBMITTAL 6'-0 O.G. PERIMETER WALLS (MIN, 3 TURNS) 12" MAX. 6" MAX, NEW NEW NEW COMBO ILLUMINATED EXIT SIGN p Q RELOCATED 2X4 FLUORESCENT EL AND EGRESS LIGHTING WITH BATTERY BACK-UP SUSPENDED CEILING ARMSTRONG 9a, FIXTURE TO REMAIN 'HEAVY DUTY' a ATTACH BRACE DIRECTLY GRID W/ 2" s^ EXISTING 2X2 FLUORESCENT TO STUD. WALL ANGLE, TYP. °14 FIXTURE 70 REMAIN •,4 EXISTING 2X4 T-BAR CEILING TO REMAIN 5a" GYP, BD, EA. SIDE 45' VERTICAL STRUTS -a 12'-O" a r T EXISTING 2X2 FLUORESCENT 45' EA. WAY (MAXIMUM) P FIXTURE TO BE REMOVED AND BEGIN NO FURTHER THAN 6' FROM WALLS, ATTACHED WALL RELOCATED 2X2 FLUORESCENT ---I—i--- COPYRIGHT LAW 311/2" SOUND BATTS ® FIXTURE TO REMAIN I IPROTECTS THE DUPLICATION ITY AT CAVI I EXISTING 2X4 T-BAR CEILING TO BE REMOVED I I OF DRAWINGS WITHOUT 4 WAY, 4-12ga DIAD, 4-' � O PROVIDE 24 HOUR NIGHT LIGHT CIRCUIT. -- -�--- THE OWNER'S CONSENT. BRACING WIRES WITHIN &'-O" WITH BATTERY BACK-UP RE-USE of ARCHITECTURAL HOUT A 45" OF WALLS TO MAIN RUNNER COPYRIGHT TRELEASE 35/a" METAL STUDS 45' WITHIN 2" OF THE INTERSEG- a EXISTING DOWNLIGHT TO BE REMOVED IS PROHIBITED g24" OC TION OF A MAIN RUNNER d NEW 2X4 T-BAR CEILING TO MATCH EXISTING A CROSS RUNNER (MIN, 3o NEW 6" LED DOWNLIGHT (3000K) TURNS) 6 SPLAYED 9N �____❑ EXISTING 4' FIXTURE TO BE REMOVED OBA 021051 ARMSTRONG FROM EA. OTHER a AN 'HEAVY DUTY' ANGLE NOT TO EXCEED 45° MAIN RUNNERs EXISTING PENDANT TO BE REMOVED FROM THE CEILING PLANE. NOTE: I. HvAC DIFFUSERS s RETURNS SHOWN ONLY CROSS RUNNER P L) D CEILING O B IN EXISTING LOCATIONS FOR CONTRACTOR'S �11NSTALLED PER ® NEW LED PENDANT FIXTURE CONVENIENCE. CONTRACTOR TO RELOCATE RECON 401 gp HVAC DIFFUSERS t RETURNS TO SATISFY .? EXISTING SPEAKER TO BE REMOVED BUILDING, MECHANICAL AND FIRE CODE. 2 TYP. WALL DETAIL CEILING BRACE DETAIL NEW LED SURFACE MOUNTED FIXTURE 2. REPLACE DAMAGED CEILING TILES — 3 11/2"1 1'-0" — 3 NOT TO SCALE ® PROVIDE DATA DROP AT CEILING FOR TENANT PROVIDED LOW VOLTAGE WIRING AND WIFI UNIT A� 3 CF 4 � dUNrA • ". j LISC#2906 OF 0 EXP.DATE 12/31/2022 15'-511/2" g _m" 23'-01/1/2 �" �" 312 N in 3� -I'-33Y231'2" J _33Y2 I _ 3J/2 J 3�" 3� 3 I'_3 N N WD-I POST 00 OPEN OPEN P.S. SOLID OPENOPEN OPEN 11/2" X 311/;" WD-I SLATS MAPLE- CLEAR \ FO. ATTACH STEEL W/214i SPACING TYP. SATIN FINISH ATTACH SLATS TO Ye" X 3 3/4" STEEL 0 TO POST WITH FLAT PS. SOLID MAPLE - FLAT BAR W/COUNTERSUNK BRACKET, TYP. FCLEAR SATIN FINISH SCREWS ABOVE t' a WD-I SLATS, TYPICAL _ OF N 000 c 0 k N O � M O ,Vail X3" STEEL FLAT BAR TYP. 1" THIGK BLOCKING gBOTTOM W/11/2"i WIDE X Y2" DEEP SLOTS FOR SPACING I/8" X 3" STEEL FLAT BAR TYP. RECEPTION - 202 -DETAIL RECEPTION - 202 1112 uo li_mn N 0 > 0) zHz w Z � Oz WI�iQaNO L_ WLu w ( � o U) U) g zZx � 0 WOOD SLAT WALL BEYOND 1--I S.S:I I I I I I I I I I .. J I. I. — ... 1 . . . . . . L . I . I j . . I I I I I IL I I I L—_ J L . J . L �J L— _ J -- L-- J L-- —J L__ J Ih n-- -n- -n 1/-I'-- -n-- n-- n- n-- SS-1 L' _ a� _' �_i �' _ _ — ®' — ll ll ll 10/03/21 - s�-1 N - - - 10/13/21 REVISED PLAM-6 FILE FILE FILE PRICING 11/22/21 REVISED PICKING 01/20/22 TENANT � RECEPTION - 202 RECEPTION - 202 CHANGES 01/31/22 TENANT CHANGES 02/01/22 TENANT CHANGES 02/02/22 PERMIT SUBMITTAL TENANT'S 21-0" m° MIGROWAVEs 13" S.S.-I ADJUST. SHELVES CTYPJ _ r _ 12" 1/ 1/ 1/ \- ---- \---- / ry PAM-5 =_ __ __ _= o] COPYRIGHT LAW SS.-2 S TENANT'S PROTECTS THE DUPLICATION OF DRAWINGS WITHOUT 24" 2m" CLR MICROWAVE THE OWNER'S CONSENT. VERIFY r a o I c0 o o f o VERIFY RE-USE OF ARCHITECTURAL �S' o� 1 a DRAWING WITHOUT ASE P.L41YAM-1 rCOPYRIGHT IS PROHIBITED in PLAM-3 r WIRE PULLS _ OBA #21051 WIRE PULLS P.LAM-2 111/2.. 11 x1i i -- --- --- --- - - --- -- - v - 1/ ` PROVIDE INTEGRAL PLAM-6 PLAM-4 TOE KICK 36" MIN. DISHWASHER BY CLEAR LANDLORD. VERIFY PROVIDE REQUIRED WIDTH W/LANDLORD LTENANT'S REFRIGERATOR PIPE INSULATION VERIFY WIDTH W/TENANT 3�4 3 RECEPTION - 202 COPY - 231 BREAK ROOM - 205 A�4 - � I.=I _m. - 4 /211e1i_mu - � 1/2 _1'-0 OF 4