Loading...
Plans (26) BUP2021 -00304 SITE HAMPTON SQUARE a a OFFICE COPY r r ® I r r r CITY OF TIGAPUX SUITE 100 " r r " r REVIEWED FOR CODE COMPLIANCE Architecture Interiors r Y Y OTC J J Planning Engineering r FORD BLACK & COO POC . Adis&° �I - 0n3ra4 4s Y TENANT IMPROVEMENT Suite Datct �.� 503.224.9560 r " r Vancouver, WA r 360.695.7879 Seattle, WA II, r206.749.9993 Lam" rr r Y Y " � r " - r 6590 SW HAMPTON ST, TI GAR D , OR 97223 r r r r " r r r r www.mcknze.com b b b ti " Yr MACKENZIE. rDESIGN DRIVEN I CLIENT FOCUSED r r Client CODE SUMMARY LEGEND INDEX OF DRAWINGS AMERICAN GENERAL PROPERTY EXIT EXIT ACCESS GO.01 TITLE SHEET, CODE SUMMARY, AND PROJECT GENERAL NOTES MANAGEMENT SITE PLAN ILLUMINATED EXIT SIGN AO.01 ARCHITECTURAL ARCHITECTURAL GENERAL NOTES, AND DETAILS Q,Q NOT TO SCALE FIRE EXTINGUISHER LOCATION A1.10 DEMOLITION, FLOOR AND REFLECTED CEILING PLANS, SCHEDULE, LEGEND AND NOTES PORTABLE FIRE EXTINGUISHERS (CLASS A HAZARD) SHALL BE PROVIDED AS SHOWN AND PER 2014 OREGON FIRE CODE TABLE 906.3(1), MAXIMUM TRAVEL DISTANCE TO A EXTINGUISHER SHALL BE 75'. IN ADDITION, FINAL PORTABLE FIRE EXTINGUISHER \A LOCATIONS SHALL BE APPROVED BY AHJ IN ACCORDANCE WITH APPLICABLE CODES SCOPE O F WORK PRIOR TO INSTALLATION. Project ACCESSIBLE MEANS OF EGRESS HAMPTON SQUARE PROVIDE MINIMUM 1 FOOT CANDLE EGRESS LIGHTING ACROSS WIDTH THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS OF APPROXIMATELY 3,227 SQUARE FEET ON THE FIRST FLOOR OF THREE FLOORS. WORK TO INCLUDE SUITE 100 - — — — — — - TRAVEL DISTANCE 300'-011 MAX. (TABLE 1017.2) DEMOLITION, NEW WALLS, DOORS, RELITES AND FINISHES. TENANT L — �i a 99'a^ (COMMON PATH OF TRAVEL <100) INPROVEMENT 61115b AWSW PION ST, I RD, OR T DESIGN/CODE DATA GOVERNING CODE: 2019 OSCC OCCUPANCY: B �J4� Akl1 f CONSTRUCTION TYPE: II-B J C/S! j TENANT AREA: 3,227 SQUARE FEET AU6nv S ! OCCUPANCY LOAD: SEE OCCUPANCY CALCULATION TABLE BELOW 3 EXITS REQUIRED: 1 ORT ON 0 EXITS PROVIDED: 1 EGRESS WIDTH: 3'-0" 0 EXITS: ALL EXITS ARE EXISTING AND HAVE APPROPRIATE EXIT SIGNAGE FIRE PROTECTION: BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTIONMACKENZIE 2021 )QT E © ALL RIGHTS RESERVED OCCUPANCY CALCULATION THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, OCCUPANCY LOAD FACTOR FLOOR AREA OCCUPANT LOAD WITHOUT PRIOR WRITTEN PERMISSION BUSINESS 1:150 3,227 SQUARE FEET 22 REVISION SCHEDULE SYMBOLS AND REFERENCES Delta Issued As Issue Date 2 CODE SUMMARY PLAN PROJECT NORTH 0,0 1 ST FLOOR - SUITE 100 NTS DEFERRED SUBMITTAL PROJECT GENE RAL NOTES NORTH ARROW TRUE NORTH 2019 OSSC SECTION 107.3.4.1 (BY SEPARATE PERMIT) ELECTRICAL A. THE DRAWINGS LOCATE PRODUCTS, SURFACES, AND MATERIALS AND THE NOTES CONVEY DESIGN INTENT. THE PROJECT INTENT IS TO PROVIDE FOR A COMPLETE, WORKING SYSTEM. FILLED ARROW PLUMBING A FIRE ALARM B. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE EDITION, AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING AUTHORITIES. DETAIL# FIRE SPRINKLER INTERIOR ELEVATION C. VERIFY AND CONFIRM ALL CONDITIONS, DIMENSIONS, AND LAYOUT INFORMATION PRIOR TO START OF CONSTRUCTION. NOTIFY MACKENZIE OF ANY DISCREPANCIES PRIOR TO START OF KEY MARK 1 2p SHEET# SUB-CATEGORY NHOESE S SDESIGN EMS/COMPONENTS SHOWN ON DOCUMEFOR NTS ARE SCHEMATIC DESIGN C ONLY YTHEYAARE NOPONENTS. WORK. ANY CORRECTION WORK REQUIRED AS A RESULT OF NOT REPORTING SUCH DISCREPANCIES SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. SHEET TITLE: D. CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY EXAMINE THE SITE AND THE CONSTRUCTION DOCUMENTS OF THE ENTIRE WORK. INCONSISTENCIES IN THE PLANS OR CATEGORY ARCHIINTENDTECT OF RECORD FORED TO REPRESENT REVIEW EV EW PRIOR TO SUBMLIANT ITTAL PROVIDE DESIGN DOCUMENT SUBMITTAL TO TITLE SHEET, CODE SPECIFICATIONS SHALL BE CALLED TO THE ATTENTION OF MACKENZIE. KEYNOTE SPACE NAME CONTACTS SUMMARY, AND E. REFER TO ENLARGED PLANS AND ELEVATIONS WHERE INDICATED FOR ADDITIONAL INFORMATION. ENLARGED PLANS TAKE PRECEDENCE OVER PLANS OF SMALLER SCALE, AND DETAILS OFFIC SPACE # TAKE PRECEDENCE OVER PLANS. IN THE CASE OF A CONFLICT, THE HIGHEST COST OPTION SHOULD BE PRICED. ROOM/SPACE IDENTIFICATION 114 PROJECT P;ISg.1 FLOOR FINISH ARCHITECT CONTRACTOR GENERAL F. DETAIL REFERENCES SHALL BE APPLIED TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR, UNLESS NOTED OTHERWISE. WALLBASE FINISH G. THE TERMS "ABOVE FINISH FLOOR" (AFF) AND "FINISH FLOOR ELEVATION" (FIFE) REFER TO FINAL FINISHED FLOOR ELEVATION, WHETHER BUILT-UP SLAB, COMPOSITE DECK, OR RAISED WALL FINISH MACKENZIE AMERICAN PROPERTY MANAGEMENT NOTES 1515 SE WATER AVE, SUITE 100 2154 NE BROADWAY ACCESS FLOOR. DOOR SYMBOL NUMBER PORTLAND, OR 97214 PORTLAND, OR 97212 DRAWN BY: SW 101A H. DO NOT SCALE DRAWINGS. CONTACT: DINA RADZWILLOWICZ CONTACT: RICKY GRANQUIST CHECKED BY: BL/ PDK I. CUTTING AND DRILLING OF STRUCTURAL MEMBERS NOT DETAILED REQUIRES THE WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD. REVISION # TEL: 503.224.9560 TEL: 503.688.3208 REVISION MARK FAX: 503.228.1285 EMAIL: RGRANQUIST@APMPORTLAND.COM SHEET: J. SAVE AND RECYCLE DEMOLITION DEBRIS AS APPLICABLE. ALL DEMOLISHED OR REMOVED EXISTING MATERIAL SHALL BE LEGALLY DISPOSED. COORDINATE WITH CITY OF TIGARD EMAIL: dmr@mcknze.com REQUIREMENTS FOR RECYCLING/RE-USE OF DEMOLITION DEBRIS. LANDLORD/OWNER G0m01 REVISION CLOUD K. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THEIR WORK. THE CONTRACTOR WILL COORDINATE CLEAN UP OF ALL AREAS AFFECTED BY DUST OR ANY AMERICAN PROPERTY MANAGEMENT MATERIALS, BOTH DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT, INCLUDING THE INSIDE OF ALL WINDOWS AS NECESSARY SO THAT THE SPACE IS READY FOR 2154 NE BROADWAY PORTLAND, OR 97212 OCCUPANCY BY TENANT. JOB NO. L. EXISTING MATERIAL NOTED TO BE RETURNED TO THE OWNER SHALL BE SAFELY STORED AND PROTECTED UNTIL IT IS REMOVED FROM THE SITE BY THE OWNER. CONTRACTOR SHALL CONTACT: DOUG LINDHOLM 2090622.08 TEL: 503.281.7779 COORDINATE WITH THE OWNER. EMAIL: DLINDHOLM@APMPORTLAND.COM PERMIT SET 01/11/2022 '221045000'\\GRP.MCK\PROJECTS\PROJECTS\209062208\DRAWING&ARCH ITECTURAL\08-G0.01.DWG SW 01/10/22 09:37 1:96.00 33 MIL 3-1/2" METAL STUD BRACING TO FLOOR STRUCTURE AT 8'-0" OC ARCHITECTURAL GENERAL NOTES WITH (2) A. OVERALL FLOOR PLANS ARE INTENDED TO IDENTIFY ENTIRE FLOOR AREA. SEE INDIVIDUAL AREA AT METAL SCRREWSSAT EACH END. BRACING TO BE PLANS FOR SPECIFIC DIMENSIONS, DETAILING, PARTITION TYPES, AND ADDITIONAL INFORMATION. PROVIDED WHERE SOUND ATTENUATION BATT B. ALL WALLS ARE TO UNDERSIDE OF CEILING GRID UNLESS OTHERWISE NOTED. ■ SPAN TABLE FOR METAL STUDS DISTANCE BETWEEN AS OCCURS PERPENDICULAR C. SEE CODE ANALYSIS PLANS FOR FIRE EXTINGUISHER LOCATIONS. INTERSECTING WALLS OR GYPSUM BOARD WALL AS D. ALL DOOR AND RELITES ARE TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. DEWINATION STUD CONDITIONS - INTERIOR PARTITIONS HORIZONTAL BRACING OCCURS Architecture - Interiors BETWEEN WALLS EXCEEDS _ _ E. ALL DIMENSIONS TO FACE OF WALL, CENTERLINE OF COLUMN, UNLESS OTHERWISE NOTED. ALIGN Planning IS Engineering CALCULATED USING 5 PSF AND L/240 4 8'-0" OC FINISHES WHERE INDICATED. 3" SOUND ATTENUATION v 362SI25-18 ALL WALLS 11'-0" TO 12'-0" IN HEIGHT - 16" OCF. DIMENSIONS MARKED "CLR" ARE FROM FINISH SURFACE TO FINISH SURFACE. DIMENSIONS WITH BATT. 4'-0" CENTERED ON DOUBLE STUD AT JAMB, THIS MARK TAKE PRIORITY OVER ADJACENT DIMENSIONS. DIMENSIONS ADJACENT TO LATCH SIDE 3625125-18 ALL WALLS UNDER 11'-0" IN HEIGHT - 24" OC SUSPENDED WALL WHERE NOTED. TYPICAL CEILING OF DOORS INDICATE REQUIRED CLEARANCES BETWEEN CLEAR DOOR OPENING AND ADJACENT ALL WALLS 12'-0" TO 16'-0" IN HEIGHT - 16" OC CUT TILE FOR TIGHT FIT FINISH. Portland, OR AT WALLS 503.224.9560 362S162-43 ALL WALLS WITH TILE FINISH GYPSUM BOARD CASING BEAD USG 200-A MATCH BUILDING STANDARD G. ALL DIMENSIONS SHOWN AS PLUS/MINUS (+/-) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. EACH SIDE FRAME Vancouver, WA ATTACH STUD TRACK H. DOORS NOT DIMENSIONED ARE TO BE LOCATED 4" FROM FACE OF WALL TO OUTSIDE EDGE OF 360.695.7879 ALL MIRRORED WALLS IN TOILET ROOMS THROUGH GRID JAMB. Seattle, WA 3625162-68 ALL WALLS 16'-0" TO 24'-0" IN HEIGHT - 12" OC SOUND ATTENUATION I. ELECTRICAL/DATA OUTLETS SHOWN FOR REFERENCE ONLY. 206.749.9993 METAL STUDS. INSULATION PER PLAN J. ALL NEW AND EXISTING OUTLETS/DATA PORT COVER PLATES TO BE BUILDING STANDARD, IN COLOR WwW.mcknze.com SEE 1/AO.01 FOR BOTTOM TRACK TO FINISH IVORY. SIZE AND SPACINGNr FLOOR WITH POWDER MACKENZIE. x DRIVEN ANCHORS AT K. PATCH AND REPAIR EXISTING CONDITIONS DAMAGED BY NEW WORK TO NEW CONDITION. DESIGN DRIVEN i CLIENT FOCUSED ¢ 4'-0" O.C. L. ALL EXISTING BUILDING ELEMENTS TO REMAIN UNLESS NOTED OTHERWISE. Client JCONTINUOUS ACOUSTIC M. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY AMERICAN ¢ SEALANT EACH SIDE COMPROMISE THE STRUCTURAL INTEGRITY OF THE BUILDING. PROPERTY A� AGAINST TRACK = Z CONCRETE SLAB }I N. 100% SPRINKLERS TO BE MAINTAINED THROUGHOUT IN ACCORDANCE WITH THE LATEST ADDITION MANAGEMENT p J ¢ uJ OF NEPA 13. SPANTABLE FOR METAL STUDS I 2 WALL — TO UNDERSIDE OF GRID 3 DOOR HOLLOW METAL ¢ O. CAP ALL ABANDONED PLUMBING, ELECTRICAL CONDUIT, AND OTHER UNDER SLAB UTILITIES AS O. NTS ¢ 00 AT FLOOR AND SUSPENDED CEILING 3"=1'-0" ¢ Q HEAD SIMILAR 3"=1'-0" 000 REQUIRED. 3 3 0 P. RE-USE ALL DEMOLISHED COMPONENTS (DOORS, WINDOWS, LIGHTS, ETC) WHERE POSSIBLE. SERVICE OR REPAIR TO PROVIDE "LIKE NEW" OPERATION AND APPEARANCE. 6A \A Q. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO OWNER FOR FUTURE USE. R. RETAIN EXISTING FIRE EXTINGUISHERS FOR FUTURE USE. Project GYPSUM BOARD WALL AS HAMPTON SQUARE OCCURS z z L3" X 3" X " POST AT SUITE 100 g = DOUBLE STUD AT JAMB, UNSUPPORTED END OF TENANT m¢w d TYPICAL UP TO [3'-6" AFF] WALLS AND 8'-0" O.C. INPROVEMENT (o LO 636'; MI N 0 22" 12 ¢ In 42 MI `F 4.—¢'U AND BOTH LATH 3-5/8" 20 GAUGE 6590 SW HAMPTON ST, METAL STUD AT 16" O.C. TIGARD, OR 97223 6 PULL SIDE PUSH SIDE MATCH BUILDING , T ANGLE SUPPORT Q 3'-0" STANDARD FRAME " ABOVE CONCRETE SLAB O HINGE SIDE APPROACH - SWINGING DOORS LU w Z GYPSUM BOARD 4KI tj Z z ¢ w w Z CD U-1 ow ow Ja ASIt 40CCURS,RPROVIDEED E 1/4 R 3/8"0 X 3" 0 w o v ao U 5 24 U 5 w w "C" CHANNEL AT TOP BASE PER FINISH PLAN I J -n m y cr w EXPANSION ANCHOR "0 `F �`of MIN �0 24 LJ U)) AND BOTTOM LU J = m ~ o a a s N X S' 0 U J 0 - U v ~ 0 =) EXISTING CONCRETE ¢ N I �o � PULL SIDE PUSH SIDE SLAB MACKENZIE 2021 1 00I W WALL PER PLAN ,o �a v © ALL RIGHTS RESERVED U • v THESE DRAWINGS ARE THE PROPERTY OF Z -- i ¢ MACKENZIE AND ARE NOT TO BE USED = LATCH SIDE APPROACH - SWINGING DOORSQ = OR REPRODUCED IN ANY MANNER, J Z WITHOUT PRIOR WRITTEN PERMISSION J z U WF_ Z K REVISION SCHEDULE 5 TYP. MOUNTING HEIGHTS s ACCESSIBLE DOOR CLEARANCES o DOOR — HOLLOW METAL SIDELIGHT s PARTIAL HEIGHT STUD WALL wl Delta Issued As Issue Date 1/4"=1'-0" ¢ Q HEAD SIMILAR 3"=1'-0" o O. 1"=1'-0" 3 SHEET TITLE: ARCHITECTURAL GENERAL NOTES, AND DETAILS DRAWN BY: SW CHECKED BY: BL/ PDK SHEET: A0m01 JOB NO. 2090622.08 PERMIT SET 01/11/2022 221021802`\\GRP.MCK\PROJECTS\PROJECTS\209062208\DRAWINGS\ARCHITECTURAL\08-A0.01.DWG SW 01/07/22 16:35 1:96.00 SUITE 1001 SUITE 108 LEGEND GENERAL PLAN NOTES �; ' F A. SEE ARCHITECTURAL GENERAL NOTES ON A0.01 FOR ADDITIONAL INFORMATION EXISTING CONSTRUCTION TO BE DEMOLISHED TYP. 02-04 (DG T B. SEE A0.01 FOR WALL TYPES V o EXISTING WALL TO REMAIN C. ALL WALLS TO BE PAINTED P-1 UNLESS OTHERWISE NOTED. PATCH AND REPAIR WALLS WHERE ■ NEW WALL TO UNDERSIDE OF CEILING, SEE 3/A0.01 AFFECTED BY CONSTRUCTION. if ® NEW PARTIAL HEIGHT WALL TO 47m AFF,SEE 8/A0.01Me D. CENTER FLOORING TRANSITIONS AT CENTER OF DOOR JAMBS, UNLESS OTHERWISE NOTED. Architecture In Interiors NEW QUADRUPLEX OUTLET E. EXISTING CARPET AND BASE TO REMAIN IN SUITE 100, ONLY. DEMOLISH FLOORING IN SUITE 108 Planning ■ Engineering TYP. 02-04 02-01 02-08 NEW DUPLEX OUTLET PORTION ONLY. 02-07 TYP F. INSTALL NEW CARPET TILE (CPT-1)AND COVED BASE (RB-1) THROUGHOUT ADDED SUITE 108, 02-05 02 06 p NEW MUDRING PER PLAN, UNLESS NOTED OTHERWISE. =" ii-------- NEW} - i=:=_c, n __________ • NEW COVERPLATE G. NEW VINYL TILE FLOORING (VCT-1) AND COVED BASE (RB-1) IN BREAK AND IT ROOM ONLY. i - - ° Portland, OR EXISTING DUPLEX OUTLET H. ALL NEW INTERIOR DOORS TO RECEIVE BUILDING STANDARD PASSAGE DOOR HARDWARE, fi i T 503.224.9560 EXISTING QUADPLEX OUTLET UNLESS NOTED OTHERWISE. Vancouver,WA ;" I. REMOVE ALL DATA OUTLETS AND PROVIDE NEW BUILDING STANDARD COVER PLATES 360.695.7879 02-03 • ° 02-02 r, p EXISTING DATA/PHONE ROUGH IN LOCATION THROUGHOUT. Seattle,WA =;' : • EXISTING COVERPLATE 206.749.9993 " J. EXISTING CEILING AND LIGHTING TO TO REMAIN THROUGHOUT, UNLESS NOTED OTHERWISE. i; U 7• Q EXISTING THERMOSTAT K. REPLACE"CUBE LIGHCOVERS WITH "CRACKED ICE"COVERS TO MATCH ALL LIGHTING WWW.mcknze.com T' _J__________________ e � 7 • •"• " «« • mm MACKENZIE. FLUSH FLOOR POWER AND DATA LOCATION THROUGHOUT COMBINED SUITE. MACKENZIE. EXISTING CEILING GRID L. REUSE DEMOLISHED COMPONENTS (DOORS AND RELITES) WHERE POSSIBLE. DESIGN DRIVEN I CLIENT FOCUSED 26-01 � ��----}{---�( Client EXISTING 2'X4' LIGHT FIXTURE TO REMAIN. HATCHED INDICATES FIXTURE ON 24-HOUR BATTERY BACK-UP. AMERICAN + EXISTING SPRINKLER HEAD PROPERTY ® NEW EXIT SIGN KEYNOTES MANAGEMENT EXISTING SUPPLY/RETURN VENT TO REMAIN 00-01 ALIGN FACE OF NEW WALL WITH FACE OF EXISTING WALL. DEMOLITIONFLOOR PLAN 02-01 EXISTING HEADER TO REMAIN. 1 .1 1/8' = V-0" 02-02 DEMOLISH I.T. CABINET. RELOCATE DATA LINES TO ABOVE CEILING GRID. 02-03 CREATE 4'X7'OPENING IN EXISTING WALL. CA \A SUITE 1001 SUITE 108 02-04 DEMOLISH EXISTING EXTERIOR WINDOW CURTAINS AND EXISTING MINI BLINDS AT INTERIOR RELITES THROUGHOUT. Project • 02-OS REMOVE ROUND FLOOR PLATE. HAMPTON SQUARE OFFICE 09-0 OFFICE OFFICE OFFICE OFFICE Q • OFFICE OFFICE 02-06 REMOVE DOOR AND RECITE FOR RELOCATION. SUITE 100 ME)'(21S2T. TYP. 4EXIST. 107 MIPT1 1AEB- 110M�7 02-07 REMOVE ALL CEILING SPEAKERS THROUGHOUT. 09-01 EXIST. CCPT-1 02-08 REMOVE ALL DOOR AND RECITE TAGS/SIGNS. LEAVE TAGS IF REMOVAL WILL RESULT TENANT P-, s [P-1p P-, e- IN DAMAGE OF DOORS. INPROVEMENT 00-01 02-09 RELOCATE EXISTING SPRINKLER HEAD IN CONFLICT WITH NEW CONSTRUCTION. _ 06-01 INSTALL APPROX. 96"OF NEW PLASTIC LAMINATE UPPER AND LOWER CABINETRY 6590 SW HAMPTON ST, r (PL-1), PLASTIC LAMINATE COUNTERTOP(PL-2), BUILDING STANDARD SINK AND TIGARD, OR 97223 OFFICE PLUMBING AT BREAK ROOM. OFFICE 09-0 08-03 00-01 06-01 00-01 5 -0" 11206-02 INSTALL APPROX. 120"OF NEW PLASTIC LAMINATE UPPER AND LOWER CABINETRY 09-01 NP' 3'-6 VCT-+ CPT-1 (PL-1)AND PLASTIC LAMINATE COUNTERTOP(PL-2). CLR BREAK 08-06 IT P-1 B- 06-03 BUILD NEW RECEPTION DESK WITH 42"TALL PAINTED SHEET ROCK FINISH PONY WALL P-' s NI WITH 12"DEEP PLASTIC LAMINATE TRANSACTION COUNTER AND 17"DEEP PLASTIC r CONFERENCE i �� J W 115 > I LAMINATE WORK SURFACE(PL-3). • OPEN OFFICE 119 EXIST. OFFICE 08-01 INFILL EXISTING OPENING. MATCH TO ADJACENT CONSTRUCTION AND FINISH. A,aD P-1 B- 00-01 L KI LI EXIST. P-' xs • 118 OFFICE 08-02 INSTALL BUILDING STANDARD RELITE (34"X76") HORIZONTALLY, CENTERED ON WALL, P-t xs CPT-7 vcr-+ BOTTOM OF FRAME 44"AFF. OFFICE • • P-1 B- °� ' 08-04 01IPM ° 08-03 INSTALL RELOCATED DOOR AND RELITE(34"X46") • 08-07 MEXISI. WORK OFFICE OFFICE 08-04 INSTALL BUILDING STANDARD DOOR WITH FULL GLASS INSERT. T oa-o2 9 06-02 101 117 114 08-05 INSTALL BUILDING STANDARD DOOR 3'X7'. 08-05 08-06 INSTALL BUILDING STANDARD DOOR WITH LOWER SLATED VENTS,APPROX. 18"X24"AT O EXIST. CPT-1 CPT-1 P-1 S 5 L _ P-1 B- P-1 6- O • • F 00-01 • D o • BOTTOM OF DOOR. �l OS-01 08-07 PROVIDE FRAMING FOR 4'X7'OPENING. • 1 a ¢ 1 —5 09-01 PATCH FLOORING TO MATCH EXISTING, WHERE FLOOR PLATES WERE REMOVED. MACKENZIE 2021 26-01 00-Ot 09-02 PROVIDE ALL EXTERIOR WINDOWS AND ALL INTERIOR RELITES WITH NEW BUILDING © ALL RIGHTS RESERVED STANDARD MINI BLINDS. THESE DRAWINGS ARE THE PROPERTY OF RECEPTIO 26-01 RELOCATE EXISTING ELECTRICAL OUTLET TO ABOVE NEW BASE CABINET. MACKENZIE AND ARE NOT TO BE USED _ 06-03 OR REPRODUCED IN ANY MANNER, m ' 100 WITHOUT PRIOR WRITTEN PERMISSION �1 v I CPT-1 2 FLOOR PLAN SCHEDULE OF INTERIOR FINISHES REVISION SCHEDULE Delta Issued As Issue Date 1 .1 1/8" = 1'-0" CPT-1: MATCH TO EXISTING CARPET IN SUITE 100 PORTION; #550/INTELLECT VCT-1: BUILDING STANDARD; #1310-WHITE BLUE, 1'X1' RB-1: BUILDING STANDARD COVE BASE; #022/ALMOND + + + PL-1: (CABINET FACES) BUILDING STANDARD PLASTIC LAMINATE; #D388-60/CRYSTAL + + + PL-2: (COUNTERTOP) BUILDING STANDARD PLASTIC LAMINATE; #7995-38/STERLING ASH PL-3: (COUNTERTOP) BUILDING STANDARD PLASTIC LAMINATE; #1880k-35/MAGNATA Q9 21 P-1: BUILDING STANDARD PAINT; RODDA, #00311 ITALIAN ICE + SHEET TITLE: Qo + + ® + + WC-1; BUILDING STANDARD MINI BLINDS, COLOR TBD DEMOLITION, + + + FLOOR AND + + 02 09 REFLECTED CEILING PLANS, + + SCHEDULE, + + + LEGEND AND + + + N I N NOTES + t. I I I 1 11 DRAWN BY: SW CHECKED BY: BL/PDK SHEET: A1 . 10 3 REFLECTED CEILING PLAN JOB NO. 2090622.08 1 .1 1/8" = 1'-o" PERMIT SET 01/11/2022 `221021802'\\GRP.MCK\PROJECTS\PROJECTS\209062208\DRAWINGS\ARCHITECTURAL\O8-A1.10.DWG SW 01/07/22 16:35 1:96.00